Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹20.0 LAccepted-AOC BABU RAM THAKUR NIWAS BELOW UTTAM GAS AJANCY DISTT SHIMLA | SHIMLA | HIMACHAL PRADESH | 171001 | L1 | Accepted-AOC Accepted | |
| 2 | Not Admitted-Fee/PreQual/Technical | - | Not Admitted-Fee/PreQual/Technical Not Complied with technical specification |
Tender Value
₹12.0 L
EMD Value
₹24,000
Closing Date
29 Jul 2019, 11:00 amClosed
Executive Engineer
IPH Division Rohru
SH Construction of 1No Pump House cum attendant quarter below 50BHP Construction of 3Nos RCC storage tank of 43000ltr cap at node 1 21000ltr cap at node 2 and 11000 ltr cap at node 3 and Trenching laying and jointing of GMS tube 15mm dia
2019_HPIPH_30030_1
IPH-RD-AB-Tender/19-2315-34
Open Tender
Civil Works
Item Rate
180 days
Rohru
Tender Document
7 documents required · 7 mandatory
₹250
Yes
EE Rohru
₹24,000
Yes
18 Apr 2020
8 Jul 2019
29 Jul 2019
8 Jul 2019
29 Jul 2019
8 Jul 2019
Amount
Excavation in foundation trenches etc. in earth work lift upto 1.50 mtrs. stacking the excavated soil not more than 3 mtr. Clear from the edge of excavation and then returning the stacked soil in 15cm. Layer when required into plinth sides of foundation etc. consolidating each deposited layer by ramming and watering and then disposing of all surplus excavated earth all kinds of soil within all leads and lifts and as directed by the Engineer-in-charge.
Providing and laying cement concrete work 1:4:8(1cement:4approved sand:8approved graded stone aggregate 40mm nominal size) & curingcomplete excluding cost of form work in foundation and plinth with in all leads and lifts and as directed by the Engineer-in-charge.
Providing and laying cemnent concrete 1:6:12 (1cement:6approved sand:12approved graded stone agg. 20mm nominal size(twenty milimetres nominal size) and curing complete excluding the cost of form work in foundation and plinth within all leads and lifts and as directed by the Engineer-in-charge,.
Providing and laying cement concrete work 1:2:4(1cement 2sand:4graded stone agg. 20mm nominal size) and curing complete excluding cost of form work and reinforcement for reinforced concrete work in:
Foundation, footings basis of columns etc. and mass concrete within all leads and lifts and as directed by the Engineer-in-charge.
Column pillar & post upto floor two level within all leads and lifts and as directed by the Engineer-in-charge.
Suspended floor roofs landing and shelves and their support balconies, beams, girders, bressumers and cantilever upto floor two level within all leads and lifts and as directed by the Engineer-in-charge.
Stair cases (except spiral stair cases)excluding landing but including preparing of the surface and finishing of nosing upto floor two level within all leads and lifts and as directed by the Engineer-in-charge.
Providing and laying cement concrete 1:1.5:3(1cement:1.5 approved sand:3approved graded stone agg. 20mm nominal size) & curing complete excluding cost of form work in foundation and plinth:
Foundation and plinth(bed)within all leads and lifts and as directed by the Engineer-in-charge.
Wall including attached buttress, pillasters and their caps and string cources etc. upto floor two level within all leads and lifts and as directed by the Engineer-in-charge.
Providing form work with steel plate 3.15mm thick welded with angle iron frames 30x30x5mmso as give a fair finish i/c centring, shuttering, ¢ring below supporting floor to ceiling not exceeding 4mtrs. &removal of the same for in-situ reinforced concrete & plain concrete work in:
Foundation, footings basis of columns etc. and mass concrete within all leads and lifts and as directed by the Engineer-in-charge.
Column pillar & post upto floor two level square, rectangular & polygonal in plain within all leads and lifts and as directed by the Engineer-in-charge.
Beams, cantilever girders & lintals sides & soffits of beams, beams haunching cantilever girders not exceeding 1mtr. Depth within all leads and lifts and as directed by the Engineer-in-charge.
Flat surface such as soffits of suspended floor, roofs, landing and the likefloor etc. upto 200mm in thickness within all leads and lifts.
Vertical surface such as wall(any thickness) partitions and the likeincluding attached pillasters, buttresses, plinth and string cources and thelike within all leads and lifts.
Edges of slab and breaks in floors and walls under 20cm. Wide within all leads and lifts.
Slopping or battering surfaces including folded plastes:Where inclination to horizontal plane does not exceed 30degree within all leads and lifts and as directed by the Engineer-in-charge.
Stair cases with sloping or stepped soffits excluding landing beams, cantilever, girders and Lintels within all leads and lifts and as directed by the Engineer-in-charge.
Providing mild steel/tor steel for RCC work including bending binding and placing in p[osition complete upto floor two level within all leads and lifts and as directed by the Engineer-in-charge.
Half brick masonry in common burnt clay building brick in cement mortar 1:4(1cement:4sand) 1st.class brick within all leads and lifts and as directed by the Engineer-in-charge.
Providing and fixing pressed steel doors frames manufactured from commercial mild steel sheet of 1.25mm thickness i/c hinges jump lock jamb, beed and if required angle threshold of mild steel angle of section 50x25mm or base ties of 1.25mm pressed mild steel welded or regidly fixed together by mechanical means, adjustable luge with split and tails to each jamb i/c steel but things 2.5mm thick with guards, lock strike plate and shock as specified and applying a coat of approved steel primer after pretreetment of the surface as directed by the Engineer-in-charge.
Profile-A.
Profile-B.
Profile-C.
Providing and fixing Pannelled and glazed shutters for doors windows and clear storey windows including bright finish black enamel led iron butt hinges with necessary screws 40mm thick: 2nd class deodar wood within all leads and lifts and as directed by the Engineer-in-charge.
P/F wire gause shutters using MS wire gause of IS gause designation 85 G for doors windows clerestorey windows I/c bright finished black enamelled iron hinges with necessary secrews 40 mm thick 2nd class deodar wood within all leads and lifts and as directed by the Engineer-in-charge.
15 mm thick cement plaster on fair sides of brick/stone masonery convrete walls for interior plastering upto floor two level including arises internal rounded angles not exceeding 80mm girth in cm 1:6 (1cement:6sand)within all leads and lifts and as directed by the Engineer-in-charge.
20 mm thick cement plaster on rough sides of brick/stone masonery convrete walls for interior plastering upto floor two level including arises internal rounded angles not exceeding 80mm girth in cm 1:6 (1cement:6sand)within all leads and lifts and as directed by the Engineer-in-charge.
6 mm thick cement plaster in cement concrete 1:3( 1cement 3 sand in roof slabs within all leads and lifts and as directed by the Engineer-in-charge.
White washing with lime on undecorated wall surfaces(two coats) to give an even shade i/c thoroughly brooming the surface to remove all dust dirt & other foreign matter within all leads and lifts and as directed by the Engineer-in-charge.
Distempering (two coats) with oil bond distemper of approved brand and manufacture and of required shade on undecorated wall surfaceto give an even shade over and including priming coat with distemper primer of approved brand and manufacture after throughly brushing the surface free from mortar dropping and other foreign matter and also including preparing the surface even and sand papered smooth. Priming coat with distemper primer within all leads and lifts and as directed by the Engineer-in-charge.
Finishing wall with water proofing cement paint of approved brand and manufacture and of rerquired shade on undecorated wall surfaces (two coats) to give an even shade after thoroughly brushing the surface to remove all dirt and remains of loose powdered materials within all leads and lifts and as directed by the Engineer-in-charge.
Precast terrazo tiles 20m thick (with marble chipsof specified shadeand of specified laid in floor treads of steps and landingon bed on10mm thick cement plaster 1:6 (1cement6sand) jointed withneat cement slurry mixed with pigment to match the shade of tiles, silvery grey within all leads and lifts and as directed by the Engineer-in-charge.
In Skirting & riser ofsteps and dado incement plaster 1:3 (1cement:3sand) and jointed with white slurry : Silvery grey within all leads and lifts and as directed by the Engineer-in-charge.
Applying priming coat over new wood and wood based surfaces after and including preparing the surface by throughly cleaning oil, grease, dirt and other foreign matter) sand papering and knotting:Readymixed paint brushing wood primer pink within all leads and lifts and as directed by the Engineer-in-charge.
Painting two coats(excluding priming coat) on new wood and wood based surfaces with ready mixed paint brushing to give even shade including cleaning all dirt, dust and other foreign matters white paint within all leads and lifts and as directed by the Engineer-in-charge.
Painting two coats(excluding priming coat) on new wood and wood based surfaces with ready mixed paint brushing to give even shade including cleaning all dirt, dust and other foreign matters readymixed paint other than white paint within all leads and lifts and as directed by the Engineer-in-charge.
Providing and fixing of MS grill of required patttern in wooden frame of window etc. with MS rounded headed bolts and nuts or by screw: Plain Grill within all leads and lifts and as directed by the Engineer-in-charge.
Stone soling properly hand packed filling interstices with spalls and consolidating with power road roller to the required gradient and camber including spreading watering and rolling of binding materials moorum or earth etc. 100mm spread thickness (finished work including materials and labour) within all leads and lifts and as directed by the Engineer-in-charge.
Providing and fixing anodized aluminium sliding door bolts withnuts and screws complete I) 250mmX16mm within all leads and lifts and as directed by the Engineer-in-charge.
Providing and fixing anodized aiuminium. tower bolts barrel type with screws etc. complete within all leads and lifts and as directed by the Engineer-in-charge.
I) 200mmX10mm
ii) 100mmx10mm
Providing and fixing anodized aluminium .handles with screws etc. complete within all leads and lifts and as directed by the Engineer-in-charge.
I)125mm dia
ii) 100mm dia
Providing 40x3 mm flat iron hold fast 40cm. Long including fixing to frame with 10mm dia metres bolts, nuts and wooden plug and embedding in cement concrete block 30x10x15cm. 1:3:6( 1cement:3sand:6 graded stone att. 20mm nominal size) within all leads and as directed by the Engineer-in-charge.
Providing plinth protection 50mm thick in cement concrete 1:3:6(1cement:3sand:6graded stone agg. 20mm nominal size) i/c finishing the top surface of concrete smooth within all leads and lifts and as directed by the Engineer-in-charge.
Providing and laying brick tiles over mumty roofs grouted with cement mortar 1:3(1cement:3sand) over a 12mm layer of cement mortar 1:3(1cement:3sand) and finished neat within all leads and lifts and as directed by the Engineer-in-charge.
Steel work welded in built up sections, trusses and framed work, including cutting, hoisting fixing in postion and applying a priming coat of red lead paint etc.
In beams joists channels, angles tes, flats with connection plates or angle cleets as in main and cross beems, hip and jack rafters, purlins connected to common rafter and the like within all leads and lifts and as directed by the Engineer-in-charge.
Providing & Fixing of Finalax pipe 40mm dia. Under floor ( for connection cables) including all req. fitting i.e elbows, sockets etc.
Laying trenches galvanized mild steel tube (Light class) with fitting (earth work in treanches to be measured and paid for separately) including all leads and lifts and as directed by the Engineer-in-charge.
15mm dia(Fifteen milimetres)nominal size.
20mm dia(twenty milimetres)nominal size.
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .