| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹2.2 CrAccepted-AOC SECUNDERABAD | WARANGAL | TELANGANA | 506350 | ₹2.2 Cr Quoted ₹2.3 Cr | L1 | Accepted-AOC Being lowest bidder |
| 2 | L2₹2.4 Cr+₹11.2 L (4.99%)Rejected-AOC FLAT NO 002 MAHAVIR VILLA CHS LTD PLOT NO 259 SECTOR 21 NERUL EAST NAVI MUMBAI 400 706 | THANE | MAHARASHTRA | 400706 | ₹2.4 Cr+₹11.2 L (4.99%) | L2 | Rejected-AOC Not being lowest bidder |
| 3 | L3₹2.5 Cr+₹22.5 L (9.98%)Rejected-AOC DOOR NO 43 2 BESIDES VIZAG DEFENCE ACADEMY 104 AREA KAPPARADA VISAKHAPATNAM 530013 | VISAKHAPATNAM | VISAKHAPATNAM | ANDHRA PRADESH | 530013 | ₹2.5 Cr+₹22.5 L (9.98%) | L3 | Rejected-AOC Not being lowest bidder |
| 4 | L4₹2.8 Cr+₹49.9 L (22.1%)Rejected-AOC | ₹2.8 Cr+₹49.9 L (22.1%) | L4 | Rejected-AOC Not being lowest bidder |
| 5 | L5₹2.9 Cr+₹60.8 L (27.0%)Rejected-AOC NO 98 1 1C YOJANANAGAR LOHEGAON WAGOLI ROAD NEAR SIVBHA DARBAR HOTEL LOHEGAON PUNE 411047 | PUNE | PUNE | MAHARASHTRA | 411047 | ₹2.9 Cr+₹60.8 L (27.0%) | L5 | Rejected-AOC Not being lowest bidder |
| Sl No | Description | Qty | Unit | RAJENDRA CONSTRUCTION L2 | SAI RUPA CONSTRUCTIONS L1 | Mavee Syndicate L3 | Sukhdevraj Sharma Engineers & Contractors Pvt Ltd L4 | S.R.M.K Enterprises L5 |
|---|---|---|---|---|---|---|---|---|
| 1.00 | Dismantling asbestos cement (corrugated semi corrugated etc.) sheet in roof covering/ fibre sheets etc complete all as specified and directed. | 5,900 | SQM | 11 ₹64,900 | 18 ₹1,06,200 | 10 ₹59,000 Lowest | 25 ₹1,47,500 | 50 ₹2,95,000 |
| 2.00 | Supply and fix Multi rib TM profiled Pre-painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick (TCT) of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, cut as per site requirement, fixed with self drilling/self tapping screws with EPDM seal etc., complete all as specified by manufacturer specification and as directed. | 5,600 | SQM | 651 ₹36,45,600 Lowest | 720 ₹40,32,000 | 725 ₹40,60,000 | 680 ₹38,08,000 | 750 ₹42,00,000 |
| 3.00 | Supply and fix Pre-painted galvalume aluminum zinc coating GI based plain steel sheet 0.50mm thick (TCT) of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, cut as per site requirement, fixed with self drilling/self tapping screws with EPDM seal etc., complete all as specified by manufacturer specification and as directed. | 300 | SQM | 699 ₹2,09,700 | 810 ₹2,43,000 | 750 ₹2,25,000 | 680 ₹2,04,000 | 600 ₹1,80,000 Lowest |
| 4.00 | Dismantling wrought iron or mild steel work of any description not otherwise provided for etc .complete all as specified and as directed. | 220 | QTL | 501 ₹1,10,220 | 450 ₹99,000 | 200 ₹44,000 | 85 ₹18,700 Lowest | 300 ₹66,000 |
| 5.00 | Supply and Fix Roof trusses (framed) and connecting plates, etc., (cut to ordinary lenghts i.e within 20mm of the length indicated of Fe 410-W (Gde-E-250) quality A complete all as specified and as directed. | 18,000 | KG | 99 ₹17,82,000 | 90 ₹16,20,000 Lowest | 110 ₹19,80,000 | 94 ₹16,92,000 | 140 ₹25,20,000 |
| 6.00 | Fixing only Roof trusses (framed) and connecting plates, etc., (cut to ordinary lenghts i.e within 20mm of the length indicated of Fe 410-W (Gde-E-250) quality A complete all as specified and as directed. | 4,000 | KGS | 105 ₹4,20,000 | 27 ₹1,08,000 | 20 ₹80,000 Lowest | 94 ₹3,76,000 | 30 ₹1,20,000 |
| 7.00 | Material and labour for PCC 1:2:4 type B1 (using 20mm graded crushed stone aggregates) in roof curves or mud stops, copings, kerbs, channels, water through and the like including weathering, slightly rounded or chamfered angles and throating complete all as specified and as directed | 35 | CUM | 7,500 ₹2,62,500 | 5,400 ₹1,89,000 | 4,000 ₹1,40,000 Lowest | 6,000 ₹2,10,000 | 9,000 ₹3,15,000 |
| 8.00 | Material and labour for preparation of old painted steel surfaces of any description over 10cm width or girth and applying two coats of synthetic enamel paint complete all as specified and as directed. | 180 | SQM | 70 ₹12,600 | 54 ₹9,720 Lowest | 65 ₹11,700 | 87 ₹15,660 | 90 ₹16,200 |
| 9.00 | Material and Labour for preparation of new surfaces of steel, of any description, not otherwise described, over 10 cm in width or girth and applying two coats of synthetic enamel paint over a coat of red oxide zinc chrome primer complete all as specified and directed. | 880 | SQM | 78 ₹68,640 | 90 ₹79,200 | 65 ₹57,200 Lowest | 89 ₹78,320 | 90 ₹79,200 |
| 10.00 | Demolition of brickwork or stone/boulder masonry, built in cement mortar with all quoins, arches, pillars, etc but excluding ashlar facings, dressed stone work and precast concrete articles including disposal of the rubbish out off the premises complete all as specified and as directed. | 50 | CUM | 451 ₹22,550 | 450 ₹22,500 | 250 ₹12,500 Lowest | 260 ₹13,000 | 700 ₹35,000 |
Tender Value
₹3.3 Cr
EMD Value
₹4.0 L
Closing Date
29 Aug 2025, 6:00 pmClosed
Chief Engineer
Chief Engineer Chennai Zone, Island Grounds, Chennai - 600009
ADDN ALTN AND SPECIAL REPAIRS TO CERTAIN BUILIDNGS AT NO.2 TRG BN AT AOC CENTRE UNDER GE (SOUTH) SECUNDERABAD
2025_MES_722627_1
89105/E8
Open Tender
Civil Works
Item Rate
270 days
Garrison Engineer (South) Secunderabad
As per tender documents
7 documents required · 7 mandatory
₹2,000
Yes
Garrison Engineer (South) Secunderabad
₹4.0 L
Yes
13 Oct 2025
25 Jul 2025
5 Sept 2025
26 Jul 2025
29 Aug 2025
15 Aug 2025
Amount
Dismantling asbestos cement (corrugated semi corrugated etc.) sheet in roof covering/ fibre sheets etc complete all as specified and directed.
Supply and fix Multi rib TM profiled Pre-painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick (TCT) of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, cut as per site requirement, fixed with self drilling/self tapping screws with EPDM seal etc., complete all as specified by manufacturer specification and as directed.
Supply and fix Pre-painted galvalume aluminum zinc coating GI based plain steel sheet 0.50mm thick (TCT) of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, cut as per site requirement, fixed with self drilling/self tapping screws with EPDM seal etc., complete all as specified by manufacturer specification and as directed.
Dismantling wrought iron or mild steel work of any description not otherwise provided for etc .complete all as specified and as directed.
Supply and Fix Roof trusses (framed) and connecting plates, etc., (cut to ordinary lenghts i.e within 20mm of the length indicated of Fe 410-W (Gde-E-250) quality A complete all as specified and as directed.
Fixing only Roof trusses (framed) and connecting plates, etc., (cut to ordinary lenghts i.e within 20mm of the length indicated of Fe 410-W (Gde-E-250) quality A complete all as specified and as directed.
Material and labour for PCC 1:2:4 type B1 (using 20mm graded crushed stone aggregates) in roof curves or mud stops, copings, kerbs, channels, water through and the like including weathering, slightly rounded or chamfered angles and throating complete all as specified and as directed
Material and labour for preparation of old painted steel surfaces of any description over 10cm width or girth and applying two coats of synthetic enamel paint complete all as specified and as directed.
Material and Labour for preparation of new surfaces of steel, of any description, not otherwise described, over 10 cm in width or girth and applying two coats of synthetic enamel paint over a coat of red oxide zinc chrome primer complete all as specified and directed.
Demolition of brickwork or stone/boulder masonry, built in cement mortar with all quoins, arches, pillars, etc but excluding ashlar facings, dressed stone work and precast concrete articles including disposal of the rubbish out off the premises complete all as specified and as directed.
Material and labour for brick work with sub class 'B' bricks old size, straight or curved on plan exceeding 6.0 metre mean radius, walls built in cement mortar 1:6 complete all as specified and as directed
Taking down cement plaster of any description and thickness on brick walls including racking out joints, hacking for key, scrubbing down with water etc complete all as specified and as directed
M & L for rendering 15mm thick (inner 10mm layer 1:6 and outer 5mm layer 1:4) in cement mortar on fair faces of brick works or concrete surface and finishing even and fair using water proofing compound @3% of cement or as per manufacturer's Instruction for outer 5mm layer complete all as specified and directed. Note: (i) WPC will be measured and paid separately
Material and Labour for rendering 10 mm thick on fair faces of brick work or concrete surfaces in cement mortar 1:6 surface finished even and smooth without using extra cement complete all as specified and as directed
Material and labour for preparing newly plastered external wall surfaces and apply two coats of exterior emulsion weather proof paint over a coat of primer complete all as specified and as directed. Note : Paint will be applied by roller only
Material and labour for preparing newly plastered wall surfaces of walls and applying two coats of distemper oil emulsion (Acrylic Distemper) over a coat of wall primer etc complete all as specified and as directed.
Material and labour for removal of existing treatment on walls, preparationn of surfaces and applying two coats of distemper oil emulsion (Acrylic Distemper) over a coat of wall primer etc complete all as specified and as directed.
Material and labour for complete removal of existing treatment, loose flakes etc., and apply two coats of exterior emulsion weather proof paint over a coat of primer complete all as specified and as directed. Note : Paint will be applied by roller only
Dismantling wall and ceiling boards (fibre, pulp, insulation etc) or insulation boards / slabs / blankets any thickness including cover fillets etc complete all as specified and directed.
Supply and Fix 4mm thick high pressure steam cured (HPSC) pre primed self designer textured non asbestos fibre cement building board laid/ inserted to aluminium frame work in false celings including aluminium anodised snap grid frame work of size 605 x 605mm with hangers 6 mm dia. G.I. (up to 1200mm length) adjusting level fixed to roof slabs by means of ceiling cleats made out of G.I. flat 40 x 3 mm size 60mm long and expansion hold fasteners 12.5mm dia. 40mm long etc., complete all as specified and as directed.
Taking down chowkats or frames with shutters (without taking off shutters from frames) of size not exceeding 1.5 Sqms each complete all as specified and as directed
Taking down chowkats or frames with shutters (without taking off shutters from frames) of size exceeding 1.5 sqm and not exc 4.00 sqm each complete all as specified and as directed
Material and labour for plain cement concrete type C-1 1:3:6 ( 20mm graded crushed stone aggregates) for setting hold fasts , steel windows all as specified and directed.
Supply and fix bands ,straps ,supports or stays for rain water, ventilation pipes including bolts if required , hooks (stay), heavy , for large gates , hook and pintle hinges ,larges hasps and staples ,chains , hand made sliding bolts ,clamps ,holds fasta, wall ties , hooks for hanging fans , plain angle cleats for securing purlings to wood trusses or rafters ,knee piece inserts, two way and three way straps, plate washers and similar small articles confirming to Fe-290 Gde E-165
S&F pressed steel door frame 125 x 60 mm of minimum 1.25mm thick for doors with one or more rebates including necessary fixing lugs hinges lock strike plates, including PCC 1:3:6 type C0 for filling of hollow section comlpete as specified and directed . (Refer CECZ TD Drg No 533 sheet No 2/2)
S & F 30 mm thick factory made second class flush shutter (two panel) with lock rail and panel of 9 mm B.W.P. commercial ply or 12 mm veneered particle board with commercial veneering on both faces. The size of members as specified in SSR Part 1 section 8 clause 8.24 (a), kiln seasoned and chemically pressure treated. complete all as directed and specified.
Supply and Fix 2nd class hardwood factory made 35mm thick glazed and skeleton door shutters, open rebated and prepared to receive glass, gauge etc., without sash bars, edges of framing plain, chamfered, rounded fitted with cut and mitred beads for securing glass etc, size of members as specified in SSR Part 1 section 8 clause 8.24 (a) kiln seasoned and chemically pressure treated. complete all as directed and specified.
S & F Windows/ Ventilators frame fabricated from galvinised steel rolled sections (Base steel as per IS 513 "D" quality, Galvanized as per IS 277 with zinc @ of 120 gms/Sqr. Mtr) powder coated with total coated thickness of 0.58mm. Paint Specifications: Sections should be painted with Primer coat of Epoxy Primer of 5-7 microns thick, finished with Powder Coating of pure Polyester up to 50-60 microns thick. Dimensions of Sections: Sections for Frame should be of 72mm x 55mm, Section for Mullion should be of 72mm x 50mm, Section for Shutter Frame should be of 47mm x 20mm, Section for Fixing Glass Bead should be of 12mm x 12mm, and Section for fixing Fly Mesh should be of 40mm x 20mm. Fixing Details: Section for Frame Glazed Shutters and Mesh Shutters should be cut to length and mitred joined with Polypropylene Corner Brackets, Mullion Section should be joined with Frame/Mullion using Mullion Cap Ethyl Propylene Damien Monomer (EPDM) Gasket should be used all around glass in shutter and Fixed Glass. Spoon Section should be used around Fly mesh to fix Mesh in Mesh Shutter. Accessories: Each Glazed Shutter and Mesh shutter should be provided with SS Pivot Hinges – 1 set, Handle & Stay. Window Frame should be fixed to brick/ concrete masonry by using Nylon self expanding caps and driving MS electroplated 80mm long screws into the caps through frame
Glazing: Glass shutter & Fixed Glass portions should be provided with a glass of 4mm thick Plain Float Glass. Mesh: Mesh Shutter should be provided with a Stainless Steel wire mesh of 304 grade, 0.36mm nominal dia of wire and average width of aperature 1.40mm Grill: Windows should be provided with Grill made of 10mm sq. MS Bars welded to at 150mm center-to-center, 5mm x 10mm MS flat. Total grill unit should be powder coated and fixed to window frame with screws. (Ref CECZ TD Drg No - 807 sheet No 1/2 to 2/2)
Supply and Fix 150 mm extruded aluminium alloy handles, fabricated type, anodised complete all as specified and directed by Engineer-in-Charge.
Supply and Fix 300mm aluminium anodised barrel tower bolts of extruded section and fixed complete all as specified and directed by Engineer-in-Charge.
Supply and Fix Aluminium anodised alloy sliding bolt 300 mm long plate type stove enameled black with bright bolt not less than 12mm dia with and including a minimum of 6 bolts and nuts, four on bolt plate and two on staple plate and fix complete all as specified and as directed
supply and fix 300 mm long helical door springs including roller plate complete all as specified and as directed
supply and fix 150mm long floor door stopper of aluminium alloy body and tongue , anodised ,with hard drawn steel spring Fixed in floor complete all as specified and as directed.
supply and fix stainless wire cloth, 0.36mm nominal dia of wire and avg width of aperture 1.40mm and fixed with stainless steel wire staples complete all as specified and as directed.
Material and labour for preparation of new wooden surfaces of any description exceeding 10cm width or girth and applying 2 coat of synthetic enamel paint complete all as specified and as directed.
Demolition of cement concrete (unreinforced) in ground floors and paving nt exc 15cm thickness (below and above ground level) complete all as specified and as directed.
Material and Labour for 75 mm thick PCC 1:3:6, type C2 (using 40mm graded stone aggregate) in plinth protection laid in alternative bays finished even and smooth without using extra cement including making 10 mm wide grooves to full depth at 3 m interval and at every change of direction and filling the grooves with mixture of bitumen and sand mixed in the ratio of 1:3 by weight and top 10 mm depth sealed with sealing compound grade ‘A’ complete all as specified and as directed
Material and labour forming 38mm wide construction joints Glass dividing strips,3 mm thick complete all as specified and as directed
Material and labour removing plants incl complete root in wall and roof , and made good with PCC 1:1 1/2 :3 using 12.5mm graded crushed stone aggregate finished to match with existing surface complete all as specified and as directed.
supply and fix 25mm stainless steel curtain rods of Gde not less than SS-304 incl designer (antique finished) curtain rod's brackets suitable for curtain rods required nos of bracket fixed to wall with PVC rawl plug and brass screws etc., complete all as specified and as directed.
Dismantling Stone slabs and tiles of any description or thickness in floors, aprons etc laid bedded and pointed in any mortar complete all as specified and as directed.
Material and labour cement concrete 75mm thick type D-2 , 1:4:8 (40mm graded crushed stone aggregates) as in sub base complete all as specified and as directed.
Material and labour for coloured Non Skid ceramic tiles of grade B-II(a), 7 to 8 mm thick (square/ rectangular), light coloured group, area of each tile exceeding 0.18 Sqm but not exceeding 0.38 Sqm, laid in floors of pattern as approved, set and jointed in neat cement slurry and pointed in white or coloured cement over and including 15mm thick screed bed in cement mortar 1:6 complete all as specified and as directed
Material and labour for coloured Non Skid ceramic tiles of grade B-II(a), 7 to 8 mm thick (square/ rectangular), light coloured group, area of each tile exceeding 0.11 Sqm but not exceeding 0.18 Sqm, as in skirting/dado, set and jointed in neat cement slurry and pointed in white or coloured cement over and including 10 mm thick screed bed in cement mortar 1:4 complete all as specified and as directed
Material and labour for Machine cut polished cudappah stone slab 20-25mm thick laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and machine cut polishing with mirror finish as in floors, over and including 20 mm thick screed bed or bedding layer of mortar in cement mortar 1:6 complete all as specified and as directed.
Surface excavation n exc 30 cm deep and averaging 15cm deep and getting out in any type of soil complete all as specified and directed.
Removing excavated material n.exc 50 m and deposition where directed at a level n.exc 1.5m above the starting point .
Material and labour stone or boulder hard core of gauge exc63 mm but n exc 100mm deposited spread and levelled in layer n,exc 15cm thick watered and rammed to true surface complete all as specified and directed.
Material and labour for 100 mm thick PCC 1:4:8 type D2 (40mm graded crushed stone aggregates) as in sub bases , sub base of flooring finished even and rough complete all as specified and directed.
Material and labour for chequered cement concrete tiles with grey cement and pigment of size 300cmx300cmx20-25mm thick set, jointed and pointed in neat cement slurry over and including 15mm thick CM 1.6 screed bed in flooring complete all as specified and as directed.
Supply and fix 4mm plain mild steel wire, galvanished class 3, in detached work such as for mosquito nets and fixing to straining bolts and hook eyes ,etc ,complete all as specified and as directed by Engineer-in-charge
Supply and fix Bulletin/pin-in/Notice board (Green, Maroon or Blue ) of size 120cm x 90cm (4'x3') including necessary bolts and fitting complete all as specified and as directed (Refer TD Drg No.500 Sht (1/1) for details except for size)
Taking down carefully existing Unserviceable point wiring of any description / type / size of (light/fan/socket/call bell/two way/Power point) on TW batten/conduit complete including fittings and fixtures such as switches, ceiling roses, shades, brackets, sockets, holders, light fittings, call bells and removing the materials to store for keeping in safe custody for reuse at site or for taking credit including making good the disturbed surfaces of walls/floors/ceilings etc. complete all as specified and as directed.
Material and Labour for providing point wiring (Light point/Bell point) with 1.5 sq. mm (nominal area) single core PVC insulated FRLSH unsheathed multi-stranded copper conductor cable (maintaining colour code), 1100 volts grade in and including non metalic rigid PVC conduit medium grade with appropriate size with all fittings (ISI Marked) suitable for concealed wiring on brick, masonary walls etc including modular metal flush sunken box of adequate size with suitable modular plate cover for mounting modular switches, sockets, regulators etc. complete with all fittings and accessories fixed to wall/ ceiling for one light/ fan /bell point controlled by one oneway modular switches including one run 1.5 sqmm (nominal area) PVC insulated FRLSH unsheathed multi-stranded copper conductor cable green in colour for earth continuity conductor connected to common earth dolly including making good the disturbed surfaces to match with the existing specification, complete all as specified & directed at site. Notes; (i) Cutting chases in brick masonry walls/concrete surfaces for concealed conduit wiring and making good the disturbed surfaces, providing surface finishes as existing shall be deemed to be inclusive of the rate quoted (ii) Sunken modular flush sheet metal enclosures & modular cover plates shall be deemed inclusive in the quoted rates. (iii) Location of light points, 6 Amp socket points and light fittings may be decided by Engr-in-charge as per site/user requirment (iv) Wiring from the DB (distribution box) to switch shall be deemed inclusive in the quoted rates.
All as per serial item No.55 here in before but for one 3 pin 6 Amps socket outlet point controlled by one switch on independent board .
All as per serial item No. 55 here in before but for one 3 pin 6 Amps socket outlet point controlled by one switch on the same board.
All as per serial item No. 55 here in before but using 4 Sqmm single core copper conductor cable of multistranded FRLS PVC insulated unsheathed 1100 Volts grade for 3 Pin 16 Amps switch socket combination point on independent board including running of 4 Sq mm copper conductor FRLS PVC insulated cable as earth continuity conductor.
Supply and Fix modular switch 1 way 6 A, 1 Module capacity 230 volts complete all as specified and as directed.
Supply and fix electronic ceiling fan regulator modular stepped type 120W 2 module heavy duty suitable to work on 230 volts complete all as specified and as directed.
Supply and Fix modular Type shuttered Socket outlet,3 pin 6 Amps, 230 volts Two modules with ISI mark complete all as specified and directed.
Supply and Fix modular switch 1 way, 6/16 Amps, 2 module capacity 230 volts complete all as specified and as directed.
Supply and Fix modular Type shuttered Socket outlet,3 pin 6/16 Amps, 230 volts Two modules with ISI mark complete all as specified and directed.
Supply and fix ceiling rose, surface mount type, PVC/ Polycarbonate, isolated body with face bakelite 65 x 50mm, 3 terminals complete all as specified and as directed.
S & F 20 W surface / wall mounted LED batten light fitting aluminium extrusion input Voltage range 250 V, input frequency 50nHz, efficacy not less than 120 Lumen/Watt, rated life 50000 Buring hours including 2 nos PVC Connector blocks electrical connection with 3 core flexible Cu conductor cable of appropriate size from ceiling rose to the fixture complete all as specified and directed by the Engineer-in-charge.
Supply and fix in replacement of RCBO 2-Pole volts 30mA 32 Amps complete all as specified and as directed.
Supply and fixing 240V ,10 KA 'B' curve miniature circuit breaker (MCB) of single poles and current carrying capacity 5 to 32 AMP, in the MCB DB complete all as specified and as directed.
Supply and fixing in replacement sheet metal enclsosure MCB DB SPN 8 way with suitable rated bus bar 240 volts double door with magnetic locking system with common neutral link earth bar, din bar for mounting MCBs, terminal connectors for all incoming and outgoing circuits,complete all as specified and as directed.
Supply and fix Vertical loading type TPN DB 4 way double door with prov of MCCB as incoming 4P , made out of CRCA Sheet housing duly powder coated & confirming to IS specification with busbar rating not less than 160 A including Taking down of existing unserviceable TPN DB complete all as specified and as directed. Note :- MCCB shall be measured and paid separately .
Supply and fixing 415V , 10 KA 'B' curve miniature circuit breaker MCCB 4 pole and current carrying capacity 63 AMP, in the MCB DB Complete with connection testing and commissioning.
Disconnecting the power supply from the mains taking down the sub main wiring 2/3/5 core and of sizes up to 10 sq mm Aluminium conductor Complete with connection testing and commissioning..
M & L Submain concealed wiring with 2 runs of single core 6 Sqmm PVC insulated FRLSH multistranded 1100 volts grade wire, copper conductor drawn through and including non-metalic rigid PVC concealed conduit and conduit accessories of medium grade not notless than 25mm dia including one of single core 6 Sqmm PVC insulated sheated multistraned 1100 volts grade with copper conductor cable as earth continuty conductor along with the wiring and connected from DB to DB/main board including taking down and removing the existing unserviceable submain wiring complete all as specified and as directed. Note:- (1) The wiring shall be done in proper colour coding using red, yellow, blue for phases, black for neutral and green for earth (2) The cost of cutting of chases of required width and depth for conduit incl plastering, painting two coats to match the existing wall colour is deemed to be included in the rate quoted rate. (3) The three runs of copper wire one run of PVC conduit is shall be measured as one running meter.
M & L of Earthing complete with galvanised steel earth plate electrode 60cm x 60cm x 6mm thick burried directly in ground to a depth not less than 2.25m below ground level with top edge of earth plate not less than 1.5m below normal ground level connected to GI earth lead wire 4mm dia by means of bolts, nut, check nuts and washers etc of galvanised iron and earth lead protected by provision of GI pipe 15 mm bore of medium grade from earth electrode to DBs/Main switch all as shown in Electrical Plate to No 3 of SSR Part I and connected to main switch board including excavation and earth work in any type of soil, PCC chamber in 1:2:4 Type B-1 using 20mm graded stone aggregated 75 mm thick RCC cover in 1:2:4 type B-1 reinforced with 6mm dia bars at 75mm c/c both ways with 12mm dia MS bar handel made to shape, 20mm dia medium grade GI Watering pipe perforated at bottom with funnel and wire mesh, common salt and charcoal filling complete including testing on completion all as specified including taking down of existing unserviceable earthing (Note: GI pipe 15mm dia & GI earth lead 4mm dia upto 7.5m length is deemed to be included in quoted rate).
Supply and fixing LED Security light fitting 35 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistsnt, efficacy not less than 120 Im/Watts, rated life 50000 burning hours copmlete with driver, lamp bracket with impact and corrosin resistant including thermal management in multiple optics complete with IP 65/66 protection with wall mounting bracket arm OD 35 mm to 42mm including necessary electrical connection to the fixture with 3 core flexible Cu conductor cable of appropriate size and 1.5 m long bracket, having 40mm diameter light grade GI pipe, including GI clamps, nuts, bolts & washers with two coats of synthetic enemal paint over a coat of red oxide primer complete suitable for pop/grid false ceiling in all respect as specified and directed by Engineer-in-charge complete. Note: GI bracket made out of GI tubing medium grade 40mm bore, MS clamps shall be messured and paid separately.
Taking down ceiling fans, sealing cable end, dismantling blades and removing & deposit fan and blades to store & refixing after cleaning/painting in the same location as directed .
Taking down wall mounted fan, sealing cable end , dismantling blades and removing & deposit fan and blades to store & refixing after cleaning /painting in the same location as directed.
Supply and fix in replacement GI Bracket made out of GI tubing medium grade 40mm bore, approx length 0.75 m long including MS clamps made out of MS flat iron 25x6 mm, nuts, bolts, washers etc and including before fixing applying two coats of aluminium paint over a coat of red oxide primer including removing the old existing GI bracket from bldg complete all as specified and as directed complete all as specified and as directed
RAJENDRA CONSTRUCTION (BID ID -3400530)
Mavee Syndicate (BID ID -3402252)
Sukhdevraj Sharma Engineers & Contractors Pvt Ltd (BID ID -3402708)
S.R.M.K Enterprises (BID ID -3410258)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .