| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹40.1 LAccepted-Finance | ₹40.1 L | L1 | Accepted-Finance L1 |
| 2 | L2₹40.9 L+₹79,671 (1.99%)Accepted-Finance | ₹40.9 L+₹79,671 (1.99%) | L2 | Accepted-Finance L2 |
| 3 | Rejected-Technical | - | - | Rejected-Technical Eligibility has not been fulfilled |
| 4 | Rejected-Technical 43 228 5 OM VILLA GOPAL NAGAR CHIRAHULA HUZUR REWA REWA M P | REWA | REWA | MADHYA PRADESH | - | - | Rejected-Technical Eligibility has not been fulfilled |
| Sl No | Description | Qty | Unit | AAYANSH ELECTRICAL SOLUTIONS L1 | DUSHYANT ENTERPRISES L2 |
|---|---|---|---|---|---|
| 1.00INSTALLATION OF 63 KVA & 100 KVA ADDITONAL TF IN B.PLAN 2026-27 SCHEME AT VARIOUS SITE OF EDD-PILKHUWA, UNDER EDC HAPUR (56 No. Work) (DPR N0. 137,138,141,142,143,144,145,146,147,148,149,150,151,152,153,154,155,156,157,158,159,160,161,152,163,164,165,166,167,168,169,170,172,173,174,175,176,177,178,179,180,181,182,183,184,185,186,187,188,189,190,191,192,193,194,195) | |||||
| 1.01 | Carriage of all petty material of all 56 estimate, (Poly. Pin Insulator, Poly. Disc Insulator etc) from Electricity store center, Hapur to 33/11KV Sub-Station/site of work with loading and unloading at both ends on Kachha Packka road, as per direction of site incharge. | 1 | Job | 40,000 ₹40,000 | 10,000 ₹10,000 Lowest |
| 1.02 | Carriage of PCC Pole 8.5 mtrs. Long from Electricity store center, Hapur/J.E. Store to site of work with loading and unloading at both ends on Kachha Packka road, as per direction of site incharge. | 112 | Nos | 650 ₹72,800 Lowest | 700 ₹78,400 |
| 1.03 | Carriage of 63KVA/100 KVA TF from Electricity store center, Hapur to site of work with loading and unloading at both ends on Kachha Packka road, as per direction of site incharge. | 56 | Nos | 3,000 ₹1,68,000 | 2,000 ₹1,12,000 Lowest |
| 1.04 | Carriage of ACSR Weasel Conductor, from Electricity store center, Hapur/J.E. Store to site of work with loading and unloading at both ends on Kachha Packka road, as per direction of site incharge. | 4,480 | Mtrs | 4 ₹17,920 | 2 ₹8,960 Lowest |
| 1.05 | Carriage of LT ABC 3x120+1x95+1x16 sqmm from Electricity store center, Hapur/J.E. Store to site of work with loading and unloading at both ends on Kachha Packka road, as per direction of site incharge. | 6,610 | Mtrs | 4.1 ₹27,101 Lowest | 7 ₹46,270 |
| 1.06 | Providing MS Channel 100x50 sqmm and febrication of dropper channel (56NOS) suitable for DP as per RESPO/Drawing Norms and as per direction of site incharge. | 1,120 | Kg. | 60 ₹67,200 Lowest | 90 ₹1,00,800 |
| 1.07 | Providing MS Channel 125X65 sqmm and febrication of TOP CHANNEL/ DROPPER CHANNEL FOR FUSE SET / T-OFF CHANNEL (112NOS) suitable for DP as per RESPO/Drawing Norms and as per direction of site incharge. | 3,070 | Kg. | 60 ₹1,84,200 Lowest | 95 ₹2,91,650 |
| 1.08 | Providing MSAngle 125x65x6 mm and febrication of Base angle for substation 63kva/100kva (112NOS) suitable for DP as per RESPO/Drawing Norms and as per direction of site incharge. | 1,525 | Kg. | 60 ₹91,500 Lowest | 90 ₹1,37,250 |
| 1.09 | Erection of double pole structure with all accessories on PCC Pole 8.5 mtr. long, and fixing of M.S. Top & Dropper Channel, M.S. TIF Angle, E-Bracket, 11 KV Pin insulator with Pin, Disc Insulator with Disc fitting etc., as per RESPO Drawing Norms by providing all made o M.S. Flat of size 50x6 mm with proper size nuts and bolts, and jumpering etc work, as per direction of site incharge. | 56 | Nos | 6,500 ₹3,64,000 Lowest | 6,500 ₹3,64,000 Lowest |
Tender Value
₹49.1 L
EMD Value
₹49,130
Closing Date
10 Jun 2026, 12:00 pmClosed
SUPERINTENDING ENGINEER
SUPERINTENDING ENGINEER EDC HAPUR
BIFURCATION OF 11 KV LINES STRENGTHENING OF 33 KV LINES INSTALLATION OF NEW DISTRIBUTION TRANSFORMERS AND CAPACITY ENHANCEMENT OF DISTRIBUTION TRANSFORMERS UNDER BUSINESS PLAN 2026 27 WITHIN THE JURISDICTION OF ELECTRICITY DISTRIBUTION DIVISION PLK
2026_PVVNL_1152930_1
20(W)/EDCH/2026-27
Open Tender
Electrical Works
Item Rate
HAPUR
Please refer Tender documents.
2 documents required · 2 mandatory
₹3,540
SUPERINTENDING ENGINEER, EDC, HAPUR
₹49,130
19 Jun 2026
25 May 2026
10 Jun 2026
25 May 2026
10 Jun 2026
25 May 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1INSTALLATION OF 63 KVA & 100 KVA ADDITONAL TF IN B.PLAN 2026-27 SCHEME AT VARIOUS SITE OF EDD-PILKHUWA, UNDER EDC HAPUR (56 No. Work) (DPR N0. 137,138,141,142,143,144,145,146,147,148,149,150,151,152,153,154,155,156,157,158,159,160,161,152,163,164,165,166,167,168,169,170,172,173,174,175,176,177,178,179,180,181,182,183,184,185,186,187,188,189,190,191,192,193,194,195) | |||||
| 1.01 | Carriage of all petty material of all 56 estimate, (Poly. Pin Insulator, Poly. Disc Insulator etc) from Electricity store center, Hapur to 33/11KV Sub-Station/site of work with loading and unloading at both ends on Kachha Packka road, as per direction of site incharge. | 1 | Job | - | - |
| 1.02 | Carriage of PCC Pole 8.5 mtrs. Long from Electricity store center, Hapur/J.E. Store to site of work with loading and unloading at both ends on Kachha Packka road, as per direction of site incharge. | 112 | Nos | - | - |
| 1.03 | Carriage of 63KVA/100 KVA TF from Electricity store center, Hapur to site of work with loading and unloading at both ends on Kachha Packka road, as per direction of site incharge. | 56 | Nos | - | - |
| 1.04 | Carriage of ACSR Weasel Conductor, from Electricity store center, Hapur/J.E. Store to site of work with loading and unloading at both ends on Kachha Packka road, as per direction of site incharge. | 4,480 | Mtrs | - | - |
| 1.05 | Carriage of LT ABC 3x120+1x95+1x16 sqmm from Electricity store center, Hapur/J.E. Store to site of work with loading and unloading at both ends on Kachha Packka road, as per direction of site incharge. | 6,610 | Mtrs | - | - |
| 1.06 | Providing MS Channel 100x50 sqmm and febrication of dropper channel (56NOS) suitable for DP as per RESPO/Drawing Norms and as per direction of site incharge. | 1,120 | Kg. | - | - |
| 1.07 | Providing MS Channel 125X65 sqmm and febrication of TOP CHANNEL/ DROPPER CHANNEL FOR FUSE SET / T-OFF CHANNEL (112NOS) suitable for DP as per RESPO/Drawing Norms and as per direction of site incharge. | 3,070 | Kg. | - | - |
| 1.08 | Providing MSAngle 125x65x6 mm and febrication of Base angle for substation 63kva/100kva (112NOS) suitable for DP as per RESPO/Drawing Norms and as per direction of site incharge. | 1,525 | Kg. | - | - |
| 1.09 | Erection of double pole structure with all accessories on PCC Pole 8.5 mtr. long, and fixing of M.S. Top & Dropper Channel, M.S. TIF Angle, E-Bracket, 11 KV Pin insulator with Pin, Disc Insulator with Disc fitting etc., as per RESPO Drawing Norms by providing all made o M.S. Flat of size 50x6 mm with proper size nuts and bolts, and jumpering etc work, as per direction of site incharge. | 56 | Nos | - | - |
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.82 MB
Standbidnew20.pdf
Tender Documents • 0.67 MB
BOQ_2159728.xls
BOQ • 0.30 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .