Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹5.1 LAccepted-AOC | L-1 | Accepted-AOC Accepted | |
| 2 | L-2₹8.0 L+₹2.9 L (55.5%)Rejected-AOC | L-2 | Rejected-AOC Rejected | |
| 3 | L-3₹9.8 L+₹4.6 L (90.1%)Rejected-AOC NELA 140 OPP GATODJI MANDIR HIRAN MAGRI SECTOR NO 14 UDAIPUR 313001 RAJ | UDAIPUR | UDAIPUR | RAJASTHAN | 313001 | L-3 | Rejected-AOC Rejected | |
| 4 | Rejected-Technical | - | Rejected-Technical As not enlisted in c(i) Cat |
Tender Value
₹8 L
EMD Value
₹16,000
Closing Date
25 Mar 2025, 6:00 pmClosed
AGE I AF Mount Abu
AGE (I) AF Mount Abu Sirohi 307501
REPAIR AND MAINTENANCE OF HEATING AND COOLING APPLIANCES AT AF STN MOUNT ABU
2025_MES_692152_2
8429/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
Mount Abu
As per NIT
7 documents required · 7 mandatory
₹500
Yes
AGE I AF Mount Abu
₹16,000
Yes
9 Jun 2025
6 Mar 2025
27 Mar 2025
6 Mar 2025
25 Mar 2025
13 Mar 2025
Amount
M&L for Maintenance, servicing cleaning of the 1.5/2 ton split type air conditioner at site, cleaning of equipment with blower for removing dust checking the wiring, running capacitor, staring relay, overload relay, thermostat switchs condesor motor, blower/condensor fan rectification of fault, connecting and testing on load complete all as specified & directed. Note : (i) Replacement of spare or gas shall be measured and paid separately under respective items. (ii) After servicing the said ACs will be fixed to its original position.
Description all as per BoQ Srl item No 1.00 here-in-before but 2 Ton window type
Supply and charging refrigerant F-22/R-22 (Mefron/Refron) gas for 1.5/2.00 Ton Split /Window AC at site after detection and rectification of any leackage in the system by sing CO2 gas and flushing the complete system thoroughly with nitrogen gas complete all as specified & directed.
Description all as per Srl item No. 3.00 here-in-before but R-134 complete all as specified & directed. Note for Srl item No. 3.00 & 4.00 of BOQ/Sch of works : - The cost of nitrogen and CO2 gas used for leakage test and pressure test prior to filling charging gas shall be deemed to be included in this item rate
M & L for installing , testing , commissioning hermitically sealed compressor of the existing make and model incl soldering, welding, brazing and testing on load for for split type AC of 1.5 ton Cap.of any make including disconnecting, cutting and taking out u/s sealed unit (Hermitically sealed) of any capacity and make and model and removing from site for taking credit complete all as specified & directed.
M & L for installing , testing , commissioning hermitically sealed compressor of the existing make and model incl soldering, welding, brazing and testing on load for for split type AC of 2 ton Cap. of any make including disconnecting, cutting and taking out u/s sealed unit (Hermitically sealed) of any capacity and make and model and removing from site for taking credit complete all as specified & directed.
M & L for installing , testing , commissioning hermitically sealed compressor of the existing make and model incl soldering, welding, brazing and testing on load for refrigerator of 165 Ltrs capacity including disconnecting, cutting and taking out u/s sealed unit (Hermitically sealed) of any capacity and make and model and removing from site for taking credit complete all as specified & directed.
M & L for installing , testing , commissioning hermitically sealed compressor suitable for water dispenser suitable for 5 ltrs cooling capacity of the existing make and model incl soldering, welding, brazing and testing on load for capacity 1/8 or 1/10 including disconnecting, cutting and taking out u/s sealed unit (Hermitically sealed) of any capacity and make and model and removing from site for taking credit complete all as specified & directed.
S&F Allen Key Valves 1/4 inch size complete all as specified & directed
S&FAllen Key Valves 1/2 inch size complete all as specified & directed
M&Lfor Maintenance, servicing cleaning of the water dispenser at site, cleaning of equipment with blower for removing dust checking the wiring, running capacitor, staring relay, overload relay, thermostat switchs condensor motor, blower/condensor fan rectification of fault, connecting and testing on load complete all as specified & directed. Note : (i) Replacement of spare or gas shall be measured and paid separately under respective items.
S&F in repairs PVC drain out pipe, heavy duty 32/40mm dia, wall thickness 2mm complete with fittings such as nipple, clips etc complete fixed to water coolers of any capacity complete all as specified and directed by Engr-in-Charge.
Supply & replace starting capacitor 50 mfd for window type room air conditoner 2.0 ton capacity Make Apcos/Natraj/Tesla/Spark including taking Down Old U/s Capacitor of any size complete all as specified & directed.
Supply and replace running capacitor 45 mfd Make Apcos/Natraj/Tesla/Spark including taking Down Old U/s Capacitor of any size complete all as specified & directed.
S&F in repair thermostat switch for 2 Ton window type room air conditioner complete all as specified & directed.
S & F in repair Blower motor suitable for out door unit of split type AC 1.5 Ton complete all as specified & directed.
S& F in repair Blower motor suitable for out door unit of split type AC 2Ton complete all as specified & directed.
S & F in repair Blower motor suitable for in door unit of split type AC 1.5Ton complete all as specified & directed.
S & F in repair Blower motor suitable for in door unit of split type AC 2 Ton complete all as specified & directed.
S& F in repair blower fan as existing make and model / shape for window type room air conditioner 2 Ton capacity complete all as specified & directed.
S & F in repair Blower fan suitable for indoor unit of split type AC 1.5 Ton complete all as specified & directed.
S & F in repair Blower fan suitable for indoor unit of split type AC 2 Ton complete all as specified & directed.
S & F in repair air filter suitable for window type AC 2 Ton capacity as per samples complete all as specified & directed.
S & F in repair air filter suitable for split type AC 1.5 Ton capacity as per samples complete all as specified & directed.
S&F Condenser unit Suitable for 1.5 Ton Split AC of existing make and model complete all as specified and directed.
S&F in repair copper pipe of Size 1/4 inch wall thickness 25swg with AC insulation copper piping with 3 core cord wire complete all as specified and directed.
S&F in repair copper pipe of Size 1/2 inch wall thickness 25swg with AC insulation copper piping with 3 core cord wire complete all as specified and directed.
Maintenance, servicing & repair of refrigerator 165 ltrs capacity any make & model cleaning the various components and replacement of U/s Spares complete all as specified & directed.: Note: Spares shall be measured & paid saperately under respective item of BoQ.
Taking down, servicing, and refixing of Geyser 25 Ltrs by unscrewing of , MS clamps, inlet , outlet connections , any leakage Repair ,welding (if needed) & alike complete all as specified & directed.
S & F in repair heating element -1.5 KW for Geyser complete all as specified & directed.
S & F in repair heating element -2 KW For Geyser complete all as specified & directed.
S & F in repair Thermostat switch of capacity 1.5/2.0KW for Geyser complete all as specified & directed.
M& Lin repair PVC connection 15mm x 60 cm Size , Hot & Cold type complete all as specified & directed.
S&F in repair Sheet metal enclosure, powder coated single pole and neutral with two pin and earth plug and socket (Metallic) complete with one single pole MCB for 240 volts 20 Amps rating rupturning capacity 10 KA complete complete all as specified & directed.
S&F in repair PVC cable connection of size 3 core 70/.0076 and length 1.5 mtrs with 15 Amp socket on one end complete all as specified & directed.
M&L for shifting of Geaser of any capacity with dismatling and making good the disturbed surfaces cleaning after refixing the geyser including welding work of of any part of geyser if required complete all as specified and directed.
S&F in repair Geyser Assembly of any size. Suitable for 25ltr/15 ltr Geyser complete all as specified and directed.
S & F in repair PCB (Printed circuit board) with remote control For AC Split type 1.5/2.0 Ton capacity of any make as required on site complete all as specified and directed.
M & L For Making hole in Brick/stone wall for exhaust fan of size 250 mm to 350 mm Sweep,making it smooth by plastering internal surface of hole, taking down exhaust fan safely from existing site and fixing on the fresh hole Connecting to electrical cicrcuit, provisioning for Flap(metal) outside of wall for Mosquito/fly safety complete all as specified and directed.
S & F in repair Plug top 15 Amp, 3 pin complete all as specified & directed.
S & F in repair Indicator lamp for geyser Set of Two(Red & Green) Complete all as specified & directed.
S & F in repair Refrigerator/Deep freezer/Dispenser Stand Support Complete All as specified & directed.
S & F in repair Chiller tray for refrigerator compatible to 165 ltr to 315 ltr ,as required per site all as specified & directed.
S & F in repair Freezer door for refrigerator compatible to 165 ltr to 315 ltr ,as required per site all as specified & directed.
S & F in repair bulb & bulb holder for refrigerator compatible to 165 ltr to 315 ltr ,as required per site all as specified & directed.
S & F in repair Bimetal relay for refrigerator compatible to 165 ltr to 315 ltr ,as required per site all as specified & directed.
S & F in Defrost heater set of two for refrigerator compatible to 165 ltr to 315 ltr ,as required per site all as specified & directed.
S & F in Thermostat switch for refrigerator compatible to 165 ltr to 315 ltr ,as required per site all as specified & directed.
S & F in repair Condenser Fan Blade suitable for 1.5/2 Ton split AC Complete all as specified & directed
S & F in repair Geser reset/Manual reset type Auto cut (7 inch size) complete all as specified & directed.
naveen enterprises (BID ID -3269343)
RAJAWAT ENTERPRISES (BID ID -3268959)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .