| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹49.9 LAccepted-AOC | L1 | Accepted-AOC DUE TO L1 BIDDER | |
| 2 | L2₹52.9 L+₹1.2 L (2.26%)Rejected-Finance | L2 | Rejected-Finance REJECTED DUE TO L2 BIDDER | |
| 3 | L3₹54.0 L+₹2.3 L (4.45%)Rejected-Finance | L3 | Rejected-Finance REJECTED DUE TO L3 BIDDER | |
| 4 | L4₹54.3 L+₹2.7 L (5.13%)Rejected-Finance BOMDILA WEST KAMENG ARUNACHAL PRADESH PIN 790 001 | BOMDILA | WEST KAMENG | ARUNACHAL PRADESH | 790001 | L4 | Rejected-Finance REJECTED DUE TO L4 BIDDER | |
| 5 | L5₹55.7 L+₹4.0 L (7.79%)Rejected-Finance | L5 | Rejected-Finance REJECTED DUE TO L5 BIDDER |
Tender Value
₹48.5 L
EMD Value
₹97,000
Closing Date
10 Oct 2024, 3:00 pmClosed
MOHAN SINGH YADAV, IDSE
GE TENGA
PROVISION OF TENNIS COURT ALONG WITH FENCING PROVN DRAINAGE WITH SLAB COVER AND PROVN OF CHEQUERED TILE FOOT PATH AND SPECIAL REPAIR OF ROOF TIN SHEET SPL REPAIR TO 2 X ROLLING SHUTTERS AND SPL REPAIR OF TRG HUT AT RUPA OF AGE B/R UNDER GE TENGA
2024_MES_667780_2
8626/E8
Open Tender
Civil Works
Item Rate
180 days
GE TENGA
PL REFER TENDER DOCUMENTS
6 documents required · 6 mandatory
₹500
GE TENGA
₹97,000
Yes
16 Dec 2024
26 Sept 2024
11 Oct 2024
26 Sept 2024
10 Oct 2024
3 Oct 2024
Amount
Surfaces excavation not exceeding 30 cm deep and averaging 15 cm deep and getting out in soft soil all specified and directed
Surface excavation n.exc (not exceeding) 30 cm deep and averaging 15cm deep and getting out in hard/dense soil all specified and directed
M&L for 100 mm thick PCC 1:4:8 type D-2, (using 40 mm graded granite stone aggregate) in floorings including finishing the surface even and smooth without using extra cement all specified and directed
M&L for Screed bed or bedding layer of mortar 20 mm thick for laying floor finishes with CM 1:6 complete all specified and directed
M&L for Chequered cement concrete tiles 30cm x 30cm x 25mm thick,set, jointed and pointed in neat cement slurry in floors with grey cement and no pigments all specified and directed
Dismantling wrought iron or mild steel work of any description not otherwise provided for complete all specified and directed by engr in charge
S&F steel rolling shutter without ball bearing as specified including top cover, anchoring rod, hasp and staple and one shop coat of primer, erected in position as indicated, thickness of laths 1.25 mm,gear operated type with bevel gear box and crank handle.
S&F Ball bearing suitable for gear operated type rolling shutters.
S&F Safety lever locks mild steel with 4 levers for rolling shutters.
M&L preparing new steel or iron surfaces of any description over 10 cm width or girth and applying two coats of aluminium paint over a coat of red oxide primer.
M&L preparing old steel or iron surfaces of any description over 10 cm width or girth and applying one coat of aluminium paint.complete all as specified and directed
M&L for Dismantling of un serviseable existing steel rolling shutter to make the surface completely free of millscale, dirt,dust, grease and other foreign materials by scrubbing with steel brush applying grease at bearings, locks safety levers, make it able to easily open and close, refixing at same position complete all specified and directed
Dismantling of plain or corrugated steel sheeting any gauge, thickness as in roof covering complete all as specified and directed
M&L for Pre- painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified
M&L for Pre-painted galvalume aluminum zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified
M&L for plain galvanised mild steel sheeting, in ridges, hips, valley gutters, drip and straight flashing of 0.80mm thickness (minimum 275gm/sqm galvanising) complete all as specified and directed.
M&L for Steel work in tubular trusses including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to I. S.1161 1979 grade St.-240
S&F mild steel work as in wind ties and struts in fencing size including cutting tops to shape as swan neck as directed, drilling holes, notching for wire, etc.; flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or riveting, etc., and similar work conforming to Fe-290 Gde E-165.complete all as specified and directed by engr in charge
Material and labour for preparation of new steel surfaces of any description, over 10 cm width or girth not other wise described and applying two coat of synthetic enamel paint over a coat of red oxide primer complete all specified and directed
Taking down chowkats or frames with shutter (without taking off shutter from the frame) exc 1.50 Sqm but n exc 4.0 Sqm each including iron mongeries complete all as specified and directed.
Supply and fix 2nd class hard wood plain, solid, straight chowkats and frames, wrought, framed, rebated on the solid, rounded or chamfered, put together with glue pinned at joints complete, all as specified and directed
S&F of 40mm thick 2nd class hard wood Plain, framed, panelled shutters (any number of panels), with panels of timber flat on both sides (feather edged), or of veneered particle board medium density, wood particle board with commercial face veneers: supplied and fitted to chowkats
S&F 30mm thick Flush shutters, solid core construction, with Particle board core core and plywood face panels, one face is covered with decorative face veneer with lipping/frame to match complete all specified and directed
M&L for 12mm thick Toughned glass as in hinged doors, partitions automatic doors and similar work including cutting to shape, drilling holes required.
Taking down chowkats or frames with shutter (without taking off shutter from the frame) n.exc 1.50 Sqm each including iron mongeries complete all as specified and directed.
S&F 2nd class hard wood 30mm thick Glazed and skeleton shutters, divided into squared, with plain, chamfered or roun0ded, mitred and rebated sash bars, any numbers open rebated and prepared to receive glass, gauze, etc. (without sash bars), edge of framing plain, chamfered or rounded, fitted with cut and mitred beds for securing glass, etc.; sizes of members of shutters as specified in SSR Part I, Section 8. clause 8.20 (a); supplied and fitted to chowkats of indows,ventilators, etc. are provided with stiles and rails as specified in SSR Part I, Section 8 clause 8.24(b)
M&L for preparation of new or previously untreated wooden surfaces of any description, not other wise described, over 10cm width or girth and applying two coats of synthetic enamel paint over a coat of pink primer.
Supply and fix MS butt hinges medium weight, cold rolled 125mm size complete all as specified and directed.
Supply & fix Aluminium anodised barrel tower bolt 150 mm long of extruded section etc complete all as specified and directed.
Supply & fix Extruded brass handles,150mm fabricated type polished complete all as specified and directed.
Supply & fix ,Brass, sliding door bolt 250mm with sand or die-cast brass hasp, staple (bolttype) and fixing bolt with rolled or drawn brass bolts and fixedomplete all as specified and directed.
Demolition of cement Concrete(Unreinforced) in ground floors and pavings n exc 15 cm thickness (below or above ground level) complete all specified and directed by engr in charge
M&L for PCC 1:2:4 type B-1 using 20mm graded stone aggragate as in subbase 40 mm thick complete all specified and directed by engr in charge.
M&L for screed bed or bedding layer of 15mm thick in cement mortar 1:4 for laying floor tiles etc all as specified.
M&L for coloured Non - skid Ceramic tiles 7 to 8 mm thick area of each tile exceeding 0.18 sqm but not exceeding 0.38 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match
M&L for PCC type C-2, 1:3:6 (40mm graded stone agg)in 75mm thick plinth protection and path finishing surface even and smooth without using extra cement.
Dismantling Timber scantling 40 sq cm and over in section, in any position all as specified and directed.
M& L for cleansawn Second class hard-wood scantlings with framed work.complete all specified and directed
Dismantling wall and ceiling boards of any description including cover fillets complete all as specified and directed.
S&F of Anodised aluminium snap grid frame work for false ceiling all as specified
M&L for PVC insulation panels 10mm thick with EPS stuck to 1mm plain PVC sheet suitably placed in false ceiling grid made of Aluminium/G.I./M.S. as per specification and drawing
Supply and fixed 6 mm thick plywood , graded BWR, type BB fixed with nails to timber frame work fixed to ceiling surface etc complete all as specified and directed.
Supply and fixed 4 mm thick plywood , graded BWR, type BB fixed with nails to timber frame work fixed to ceiling surface etc complete all as specified and directed.
Material & labour for 2nd class hard wood plain fillets, square, rectangular or triangular in section, wrought, secured with nails having sectional area exc. 3 sqcm and n.exc 6 sqcm, complete all as specified and directed
Demolition of Brickwork or stone/ boulder masonry, built in lime mortar including all quoins, arches, pillars, etc, but excluding ashlar facings, dressed stonework and precast concrete articles
M&L PCC 1:3:6 type C1 as in block masonry with solid blocks exc 10 cm in width and set in CM 1:4 complete all specified and directed.
M&L rendering 15mm thick in CM 1:4 on concrete outer surfaces finished even and smooth without using extra cement finished even and smooth without using extra cement completed all as specified and directed.
Dismantling of floor, hearth or wall tiling including cement mortar bedding
M & L for 10mm thick rendering in CM 1:4 on fair faces of brick work or concrete surfaces finished rough to receive tiles .
M & L for Glazed coloured ceramic tiles in vertical surface 350x 250x 7 mm/ 450X 350X 7mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match.
Taking down cement plaster on brick, concrete block wall or stone walls, etc., including raking out joints, hacking for key, scrubbing down with water, etc.
Material and labour for 15mm thick rendering in cement mortar (1:4) on brick or concrete surfaces in external painting with WPC.
M&L for Preparing newly plastered surfaces of wll and applying two coats of cement base paint over a coat of white wash complete all as specified and directed
Demolition and breaking up drain pipe of CI/AC/PVC pipes pipes 100mm dia.
S&F PVC (SWR) pipes single sockted 110mm dia in any length with rubber ring joints fixed to walls complete all specified and directed by engr in charge
S&F PVC (SWR) pipes single sockted 75mm dia in any length with rubber ring joints fixed to walls
S&F PVC (SWR) bends any radius, with access door 110mm dia.
S&F PVC (SWR) junction single, (single T) equal or unequal 110mm dia
S&F PVC (SWR) bends any radius, with access door 75mm dia.
S&F PVC SWR reducersof 75mm.
S&F PVC (SWR) floor trap, 75mm dia outlet, plain with grating incl jointing with solvent cement.
S&F in repairs15mm bore bib tap, chromium plated brass , fancy type with capstan head screwed down, screwed for iron pipe all as specified and directed.
S&F in Repairs15mm dia angle valve/stop valve chromium plated cast copper alloy fancy type screwed down high pressure with capstan head screwed both endsfor iron pipe or for union complete.
S&F Gun-metal 20mm bore globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed.
S&F Gun-metal 15mm bore globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed.
Taking up or down 15 mm bore steel tubing and connections.
Taking up or down 20 mm bore steel tubing and connections.
S & F 15 mm bore Galvanized Steel tubes, medium grade with all fittings for water supply pipes fixed to walls or laid in trenches .
S & F 20 mm bore Galvanized Steel tubes, medium grade with all fittings for water supply pipes fixed to walls or laid in trenches .
Dismantling of water tanks exc 500 ltrs & n exc 1000 ltrs capacity and removing to stores.
S & F poythene water storage tank of 1000 ltrs capacity rotational moulded (multilayered, cylindrical vertical with closed top) hoisted and fixed in position all as specified
S & F Ball brass valves, high pressure, with polythene float and flynut complete, screwed for iron pipe pf 20mm dia or brass ferrule and fixed all as specified and directed.
Excavation in trenches not exceeding 1.5m wide and not exceeding 1.5m in depth; for foundation/ and getting out in any type of soil, all as specified and directed..
M&L for 100mm thick Soling (or sub base) with broken boulders or quarried stone, inter stices filled, surface formed and rolled and consolidated to required gradient and camber complete all as specified and directed.
M & L for PCC (1:4:8) type D-2 (40 mm graded stone aggregate) Cement in foundations,filling and mass concrete complete as specified and directed by engr in charge
M & L for PCC (1:2:4) type B-2 (40 mm graded stone aggregate) Cement concrete in surface channels and drains completed.
M&L precast solid block masonry of block 1:2:4 type B-1 wall exceeding 10 cm in width and built in cement mortar 1:6 complete all as specified and directed.
Returning filling in incl spreading,levelling, watering and well ramming in layers n.exc 25cm.in any soil
Removal of surplus soil of distance not exceeding 50 meter and depositing where directed at a level not exceeding 1.5 meter above the starting point complete all as specified and directed..
M&F for providind PCC Type B1 1:2:4 using 20mm stone aggregate, cement concrete in coping complete all as specified and directed
M&L for reinforcement cement concrete type B1 1:2:4 (20mm stone aggregate) in landings, cover slabs for drain chullah hoods, chajjas, water troughs, mangers, shelves and similar articles with plain faces complete as specified and directed by engr in charge
M&L for Mild steel TMT bars 6mm to 8mm dia, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with mild steel wire (annealed) not less than 0.9 mm dia., or securing with clips.
S&F Glass dividing strips, 3 mm thick,38mm width and inserted in position to confirm to design.
M&L for PCC 1:2:4 type B-0 using (12.5 mm graded stone aggragate) as in subbase 25 mm thick and finished even and smooth with using extra cement complete all specified and directed by engr in charge.
Preparation of newly plastered Surfaces of any description over 10cm girth or width, and applying two coats of synthetic enamel paint over a priming coat complete all as specified and directed by engr in charge
Excavating in post holes (or similar holes) each n.exc 0.5 cum, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm in hard / dense soil.complete all as specified and directed by engr in charge
M&L for PCC 1:2:4 type B-2 (40mm graded aggregate) as in walls or retaining walls, any thickness,size or shape columns, pillars and posts (incl caps and base).
S&F Mild steel screw bolts (machine made) with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut,exc 5cm but n exc 10cm long. diameter of neck 5 to 10mm complete all as specified and directed by engr in charge
Supply only Chain link MS galvanisd fencing, any size or type complete all as specified and directed by engr in charge
Fixing only chain link fencing including line wires, any mesh, size and type to any type of standards, rails, straining bolts, etc. including provission of binding wire. complete all as specified and directed by engr in charge
S&F mild steel Tie bars 10mm dia with screwed ends, nuts, washers and mild steel plates for walls, chimneys, roofs, arches, etc. king rods and straining bolts conforming to Fe-290 Gde-E-165.complete all as specified and directed by engr in charge
M&L for preparation of new steel Surfaces of any description, n.exc10cm in width or girth when unconnected with other painting or when painted in a different tint and applying two coat of synthetic enamel paint over one coat of red oxide primer.complete all as specified and directed by engr in charge
M&L mild steel work as in gate framed work of angle or other section with gusset plates braces etc conforming to Fe 410-W(Gde-E-250( Quality A complete all as specified and directed by engr in charge
S&F of Rolled sections as in main and cross beams, hip and jack rafters; purlins where connected to common rafters and running rails and guides for sliding doors; fixed with angle cleats or other connecting plate Fe- 290 gde E-165) complete all as specified and direcetd
S&F of Bands, straps, supports or stays for rainwater, ventilating pipes, including bolts, if required: hooks (stay), heavy, for large gates; hook and pintle hinges: large hasps and staples; chains; hand made sliding bolts; clamps; hold fasts; wall ties; hooks for hanging fans; plain angle cleats for securing purlins to wood trusses or rafters; knee piece inserts; two way and three way straps, plate washers and similar small articles conforming to Fe-290 Gde-E-165 complete all as specified and directed
Demoloition of cement concrete of any description and in any situation not otherwise specifically provided for complete all as specified and directed by engr in charge
M&L for 75mm thick Cement concrete type B- 2, 1:2:4 (40mm graded aggregate) in sub base complete all specified and directed by engr in charge
Supply only Integrated water proofing compound
M&L for Applying evenly a coat of blown type bitumen at the rate of 1.50 kg per square metre and blinding with clean dry sand @ 0.05 cu. m. per sq. m complete all specified and directed by engr in charge
M&L for Polythene film, 100 micron thick, laid on a coat of bitumen primer, @ 0.30 to 0.50 kg per sq. m complete all specified and directedby engr in charge
M&L for Wire brushing and cleaning topsurface of tiles, lime terracing or cement concrete, including flashings and junction of parapets, etc., and surface painting, with a layer of blown grade bitumen of any penetration applied hot @ 1.7 kg per sq. m, blinded with grit or pea size gravel @ 0.006 cu.m per sq.m, and lightly tampered (area of flashings, etc., shall be added to the roof area) as specified and directed
M&L for 40 mm thick Cement concrete 1:2:4 type B-0 using 12.5mm grade stone aggregate laid on roof incl rendering 15mm thick in CM 1:4 on concrete surfaces WPC @ 3% by weight of cement finished even and smooth with neeru finish using extra cement complete all as specified and directed.
S&F of APP based polymeric membrane minimum weighing 3kg/sqm and minimum 3mm thick reinforced with polyster non wove fabric (wt. not less than 150 gms/sqm) land on primed surface by forced application complete all as specified.
M&L for Forming square grooves in plaster n exc 12mm deep and n exc 15mm on face complete all specified and directed
M&L for in replacement of Point/fan wiring with 1.5 sq mm (nominal area), PVC insulated unsheathed (FRLSH), 1100 volts grade, multi-stranded copper conductor, in and including PVC pipe of adequate size with all fittings and accessories) including PVC insulated and unsheathed (FRLSH) single core multi-stranded copper conductor cable of size 1.5 sq mm green in colour as earth continuity conductor connected to common earth dolly complete all as specified and directed.
All as per item No. 106 here in before One 3 pin socket outlet, 5 Amps on the same board with other switches, with cables 1.5sq. mm size
All as per item No. 106 here in before but for one 3 pin socket outlet 5 Amps three pin controlled by one switch on independent board complete all as specified directed.
M&L for in replacement of Point wiring with 2.5 sq mm (nominal area), PVC insulated unsheathed (FRLSH), 1100 volts grade, multi-stranded copper conductor, in and including PVC pipe of adequate size with all fittings and accessories) including PVC insulated and unsheathed (FRLSH)single core multi-stranded copper conductor cable of size 2.5 sq mm green in colour as earth continuity conductor connected to common earth dolly complete all as specified and directed.
Supply & fixing Modular switch 1 way 6A,1 module, 240 Volts complete all as specified & directed.
Supply & fixing Modular switch 1 way 16A,1 module, 240 Volts complete all as specified & directed.
Supply & fixing Modular Socket, 6A - 2/3 pin combined 2 module, 240 Volts complete all as specified & directed.
Supply & fixing Modular Socket 6A/16A - 2/3 pin combined 2 module, 240 Volts complete all as specified & directed.
S&F modular White cover plate with frame 03 module
S&F modular White cover plate with frame 04 module
S&F modular White cover plate with frame 06 module
S&F modular Metal flush box 3 module
S&F modular Metal flush box 4 module
S&F modular Metal flush box 6 module
S&F in replacement of LED luminaire 600 mm x 600 mm, 35/36 watt, 220 V AC recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size complete.
Supply and fix exhaust fan made of sturdy Engineering plastic complete with louvers shutter, voltage 230V, 50 Hz, RPM 1200, Copper winding of sweep 150/230 mm
Taking down exhaust fan 150/230 mm dia from existing and removing all electric connections, fixing arrangement for depositing to Mes store yard for BER board
S&F in replacement of downlighter round 15 W & Driver incl integrated electronic driver including taking down old unsv one complete all as specified and directed of
Supply and fix sheet metal enclosures for DBs when MCBs to be used 230 volts 8 way 200 Amp rated busbar single pole and neutral fixed on wall duly grouted in solid block wall or on wooden board.
S&F MCB SPN having braking capacity 10KA, 32 Amps, C Curve 240 V complete all as specified and directed.
S&F MCB SP having braking capacity 10KA, 6 to 32 Amps C Curve 240 V complete all as specified and directed.
S&F wire for circuit/sub main wiring with 1100 volts grade double core PVC insulated and unsheathed cable with multistranded copper conductor 4 Sqmm, on surface or recessed or drawn in PVC casing capping/PVC Pipe along with 4 Sqmm single core copper conductor multi stranded cable as earth continuity conductor complete all as specified and as directed.(Note: One RM PVC casing capping/PVC conduit ,one run of 4 sqmm earth wire and 2 Run of 4 sqmm cable shall be measured as one run.)
Taking down point wiring carefully copper/ aluminum (light,fan, socket or power) complete (fittings such as switches ceiling rose, pendents, regulators, sockets etc)
Taking down main switches, DBs alongwith existing board and removing the same from the site and making good the disturb surfaces / Portion of the wall etc all specified and directed by EIC.
Taking down sub main wiring of any type and size and discription incl removal from DBs etc and removal of the same from site and making good the disturb surfaces or portion of wall/ceiling etc complete all as specified and directed by EIC.
M/S DKT CONSTRUCTION (BID ID -3127276)
M/S POLAR AGENCIES (BID ID -3127007)
M/S R N ENTERPRISES (BID ID -3126942)
M/S RARAI ENTERPRISES (BID ID -3127170)
M/S Karkies Construction & Co. (BID ID -3127121)
M/S KUNKAPU ENTERPRISES (BID ID -3127036)
MS SANGRILA SYNDICATE (BID ID -3127225)
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .