Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹23.9 LAccepted-AOC 708 PREM NAGAR KARNAL HARYANA 132001 | KARNAL | KARNAL | HARYANA | 132001 | L1 | Accepted-AOC work allotted | |
| 2 | L2₹27.0 L+₹3.1 L (12.9%)Rejected-Finance | L2 | Rejected-Finance L2 |
Tender Value
₹22.9 L
EMD Value
₹45,800
Closing Date
21 Dec 2021, 2:00 pmClosed
Executive Engineer
Executive Engineer, Elect. Division PWD BandR Br., Karnal (0184-2265696)
Construction of SDO Civil Complex at Indri Distt. Karnal (Pdg. Electric Sub Station only)
2021_HRY_198704_1
Substation SDO Civil Indri
Open Tender
Electrical Works
Works
120 days
Karnal
Please refer Tender documents.
3 documents required · 3 mandatory
₹1,000
₹45,800
26 Apr 2022
6 Dec 2021
21 Dec 2021
6 Dec 2021
21 Dec 2021
6 Dec 2021
Amount
23.22 MCCB ,DISTRIBUTION BOARDS, MCB's, RCCB's, CHANGE OVER etc. Supply and erection of Modular case circuit breaker single pole/4 pole on existing wall/pedestal/Panel including bounding to earth and making necessary connections required to complete the job in all respect up to the entire satisfaction of the Engineer-in-charge of the work. 23.22.1.3 TRIPLE POLE MCCB 16 to 100 Amp
23.22.1.4 TRIPLE POLE MCCB 125 to 160 Amp
23.22.1.7 TRIPLE POLE MCCB 400 Amp
23.22.1.12 Four pole MCCB 300 to 400 amp
23.24.1 Supply and erection of M.S. angle iron frame duly welded for housing M.S. sheet & main switches etc. on it, fixed on wall by means of suitable size of rag bolts with cement concrete, duly painted with three coats of approved paint including one coat of red oxide.
23.26 SAFETY ITEMS Supply and erection of Medium Voltage caution notice plate of size 200*150 mm in three languages.
23.26.2 Supply and erection of High Tension Voltage caution notice plate of size 250*200 mm in three languages.
23.26.3 Supply and erection of shock restoration chart in glass frame.
23.26.4 Supply & Erection of mild steel bucket stand suitable for 6 Nos. fire buckets,(but without bucket) including the cost of welding and painting of complete stand will one coat of red oxide and 2 coats of approved paint of red colour with all labour and material required to complete the job in all respect up to the entire Satisfaction engineer in charge of the work (size 6'x4' made of GI pipe 32mm dia).
24.1.1 Earthing with GL earth pipe 4.5 m long and 40 mm dia with masonry enclosures on the top etc. (but without charcoal or coke and salt) as required.
24.1.2 Extra for using salt and char coal/coke for pipe earth electrode as required.
24.1.4 Earthing with tinned copper earth plate 600mmx600mmx3mm thick including accessories and providing masonry enclosures with cover plate having locking arrangement and watering pipe etc. (but without charcoal or coke and salt) etc. complete as required.
24.1.5 Extra for charcoal or coke and salt for G.I. plate or copper plate earth electrode.
24.1.6 Supplying and laying 25mm x 3mm G.I. strip at 0.5 metre below ground as strip earth electrode including soldering etc. as required.
24.1.9 Providing and fixing 25 mm x5 mm copper strip in 40 mm dia G.I. pipe from earth electrode as required.
24.1.10 Providing and fixing 25 mm x 5mm copper strip on surface or in recess for connections etc. as required with all labour and material.
24.2.7 Supply and erection of suitable compression type brass cable glands for underground Cable :- 240 sqmm to Cable 3 to 32 Core
24.2.8.13 Supply and erection of aluminium lugs heavy duty including crimping etc. upto the entire satisfaction of the Engineer- in-charge of the work. 240 sqmm
24.3.3.1 Supplying and making indoor cable end termination with heat shrinkable jointing kit complete with all accessories including lugs suitable for following size of 3 core, XLPE aluminium conductor cable of 11 KV grade as required : 70 to 120 sqmm
24.3.4.1 Supplying and making outdoor cable end termination with heat shrinkable jointing kit complete with all accessories including lugs suitable for following size of 3 core, XLPE aluminium conductor cable of 11 KV grade as required : 70 to 120 sqmm
24.5.2.6 S/E mark double walled corrugated (DWC) HDPE, pipe 10 Kg/Cm2 ,laid 0.75 Mtr below ground level including diging and refilling of earth including cost of suitable size socket/cuppler for HDPE pipe including the cost of labour and material required to complete the job in all respect up to the entire satisfaction of Engineer in charge of the work. DWC/HDPE pipe 145/123 mm outer dia/ inner dia
24.7 Providing RCC foundation of M20 grade (1 Cement:1.5 Stone aggregate: 3 Coarse sand) i/c excavation, steel reinforcement (Fe 500) @ 50 kg/cum of concrete contents, concrete cover 50mm, over a bed of 75mm thick PCC 1:5:10, of required dimensions as per OEM recommendations to provide levelled surface for placement of the DG set complete in all respects and as per directions of Engineer-in-charge (Size of foundation assumed = 5.0x1 .Bx1 .Om)
24.10.1 Digging & refilling of trench 30 cm wide below ground level for erection of pipe/cable (up depth of 1 Mtr. underground cable excluding the cost of cable/pipe complete in all respect.
NS Items Supply and erection of MS Channel 100x 50x6mm including cutting bending to the required shape drilling hole carriage Painting loading unloading complete in all respect upto the entire satisfaction of Engineer-in-charge. (As per UHBVNL make and specification)
Supply and erection of MS angle 50x50x6mm including cutting bending to the required shape drilling hole carriage Painting loading unloading complete in all respect upto the entire satisfaction of Engineer-in-charge. (As per UHBVNL make and specification)
Supply and erection of MS flat 50x6mm including cutting bending to the required shape drilling hole carriage Painting loading unloading complete in all respect upto the entire satisfaction of Engineer-in-charge. (As per UHBVNL make and specification)
Providing and fixing of Nut and Bolts of size as per ISI specifications of Engineer-in-charge. (As per UHBVNL make and specification)
Supply and erection of underground armoured cable loose in existing pipe or trenchless Make Polycab/ Grandlay/ RRKabel/ KEI/ Suraj/ Havells 240 sqmm 3.5Core
Supply & Erection of rubber mat of size 1Mx2 M X 6mm thick suitable for 11 KV ISI marked complete in all respect upto the entire satisfaction of the engineer In-charge of the work.
Supply and erection of prestressed cement concrete pole as per IS : 1678-1960. 11 metres long 152 mm x 203 mm at top and 152 mm x 368 mm at bottom with working load of 360 Kg. burried 2.20 m in ground.
Supply and erection of HT XLPE cable 95sqmm 3 core Make Havells/ Polycab/ KEI/Gemscab including the cost of i-bolt for holding of cable etc. including required material to erect on existing PCC pole complete in all respect up to entire satisfaction of Engineer-in-charge of the work.
Supply & erection of GSL wire 7/8 SWG conforming to ISS 280/1975/1963 with latest amendment complete in all respect upto the entire satisfaction of Engineer-in-Charge of the work
Supply & erection of lighting arrestor model ALPRO / Alastem / LEMCO make suitable for 11KV 3 Phase 50 HZ ground neutral system comprising of spare gape type queen gap type in series with non linger resitar element house in Horizontally scale poreclam bushing with line and ground terminal along with mounting clamps conforming to ISS 3070 (Part-I) of 1985 with latest amendment with all labour and material required to the complete in all respect up to entire satisfaction of the Engineer-in-Charge of the works.
Providing & fixing of stay set complete in all respect upto the entire satisfaction of Engineer-in-Charge.
Providing & fixing of stay wire complete in all respect upto the entire satisfaction of Engineer-in-Charge.
Supply & erection of 11KV pin insulator (Jayshree make) with pin with all labour and material required to the complete the job included the fixing the same on existing channels up to entire satisfaction of the Engineer-in-Charge of the works.
Supply & erection of 11KV gang operated switch Jayshree make conforming to IS with latest amendment including suitable size of copper blade erection of same on the existing 'H'pole with the help of 3 Nos. channels of size 75mmx40mmx6mm, 1.8M long fixed with suitable size of MS clamp, nuts and bolts including cost of 6 Nos. 11KV insulator with GI pin, RD fuses and painting with 2 coat of approved paint and one coat of red oxide material required to complete the job in all respect up to entire satisfaction of the Engineer-in-Charge of the works.
Supplu and erection of ACSR conductor wire 50 sqmm with accessories including stringing and sagging of conductor of various sizes as well as jointing and binding with insulator at supports complete in all respect up to entire satisfaction of Engineer-in-charge of the work.
Supply Erection Testing & Commissioning of 11kV indoor HT metering panel indoor / outdoor complete with C.Ts P.Ts Cubical .as per requirement / approved by UHBVNL consisting of the following. - Cubical panel free standing floor mounting type made out of sheet steel 16 SWG CRCA sheet with channel iron base frame spray painted with strong synthetic light grey enamel paint as per size and design approved by the UHBVNL. - 3 Nos. 11KV CTS of rating as approved by UHBVNL for indoor installation of approved make of UHBVNL. - 1 Nos. 11KVPTS 11000/10 VA burden 0.5 accuracy oil filled suitable for indoor installation of approved make of UHBVNL. The cubical panel will be completed in all respect including inter connection, internal wiring with PVC copper cable, its testing and approval of all item by UHBVNL cost of all testing/ approval charges or all items of UHBVNL with a guarantee of one year from the date of commissioning. including cost of all labour and material required to complete the job in all respect upto the entire satisfaction of the engineer in charge of the work
Supply and Erection of HT Trivector (DLMS compliant Meter (Category-A) with all acessories for complete installation as per tech, specifitcaiton no CSC-45/Rev 11/DH/UH/P&D/2015-16 subject to change in parameters i.e. voltage ratio 33 KV /110V, 0.2 accuracy class, current ratio-/1A
Supply & Erection of fire buckets of 9 ltr. capacity made out of 24guage G.l sheet and duly painted with one coat of red oxide and 2 coats of approved paint in red colour and written with the fire' as per fire protection necessar sand filling in the bucket hung the bucket on stand with all labour and material required to complete the job all respect up to entire \satisfaction of the Engineer m charge of the work
S/E/T/C of Oil filled 11/0.433KV CU Wound 3 PH 315KVA transformer with Off load tap changer as per IS 1180 Level 2 Make Kirlosker/ ABB India/ Siemens/ Schneider/ Crompton.
Supply & Erection of cubical type dust and Vermin proof LT automatic power factor control panel 150KVAR capacity. suitable for automatic operation and control of power factor within the set limits free standing floor / wall mounting made out of 16 gauge M.S. sheet duly powder coated suitable for operation of 3 phase 4 wires 50 cycles per second 400/440V.A.C. supply equipped with the following. - 1 No. automatic power factor control relay of GE/L&T/ Neptune make. Incomer MCCB (35KA) = 100amp. with back up protection of HRC Connection from incomer MCCB to bus bar by means of copper wires of suitable size of requisite capacity insulated with PVC. 2 No. 25 KVAR, 9 no. 10 KVAR & 2 nos 5 KVAR capacitor of L&T /GE / Neptune make. (Total 150 / KVR) Installed and duly wired inside panel with axial flow fan controlled through thermostat. The panel will be complete with all internal wiring with PVC copper wire, inter connection etc. complete in all respect with all labour and material up to the entire satisfaction of the Engineer-in-charge of the work.
Supply & Erection of fire extinguisher ISI marked Co 2 type 4.5 Kg. Capacity as Per ISI 7285 Make: Ajay, Zenith, Minimax.
MS Sarwan Automation and Solution
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .