Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹2.6 LAccepted-AOC | L1 | Accepted-AOC Lowest bid | |
| 2 | L2₹3.4 L+₹78,075.80 (29.6%)Rejected-Finance | L2 | Rejected-Finance Highest bid |
Tender Value
₹14 L
EMD Value
₹7,000
Closing Date
3 Apr 2023, 5:00 pmClosed
The Chief Officer
Indapur Municipal Council
Annual maintenance contract of Electrical department for Indapur Municipal Council for year 2023-24
2023_DMA_883573_3
IMC/Light/01/2023-24
Open Tender
Electrical Works
Item Wise
365 days
Indapur
Please refer Tender documents.
2 documents required · 2 mandatory
₹1,000
₹7,000
26 Sept 2023
29 Mar 2023
5 Apr 2023
29 Mar 2023
3 Apr 2023
29 Mar 2023
Amount
Supplying & erecting mains with 2x10 sq.mm F.R copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places as per specification No: WG-MA/BW
Supplying & erecting mains with 2x6 sq.mm F.R copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places as per specification No: WG-MA/BW
Supplying & erecting mains with 2x4 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places. as per specification No: WG-MA/BW
Supplying and erecting mains with WP 2 x 6 sq. mm. 1100 V grade aluminium PVC insulated and PVC sheathed wires on G.I. bearer wire No. 8 SWG complete erected with required size of porcelain reel insulators and 16 SWG G.I. binding wire.
Supplying and erecting mains with WP 2 x 4 sq. mm. 1100 V grade aluminium PVC insulated and PVC sheathed wires on G.I. bearer wire No. 8 SWG complete erected with required size of porcelain reel insulators and 16 SWG G.I. binding wire
Supplying and erecting ISI mark G.I. pipe pole ‘B’ grade 80 mm dia 6 m long with pole cap, base plate in provided foundation as per specification no. OH-PL/GIP
Supplying and erecting rolled steel joist (girder) pole 125 x 70 mm (13.3 kg/m) with base plate in provided foundation as per specification no. OH-PL/RSJ
Supplying and erecting steel tubular swaged pole 139.7 x 114.3 x 88.9 mm dia with 4.5 x 3.65 x 3.25 mm thickness (5+2+2 m ) length respectively and total 9 m long with pole cap, base plate in provided foundation (weight 113 kg) as per specification no
Providing & erecting 7 m high (clear height) galvanised octagonal pole with foundation bolts having bottom of 130 mm A/F, top 70 mm A/F on provided foundation as per specification no. OH-PL/OPL
Providing & erecting 9 m high (clear height) galvanised octagonal pole with foundation bolts having bottom of 155 mm A/F, top 70 mm A/F on provided foundation as per specification no. OH-PL/OPL
Providing and erecting galvanised 1000mm single arm sword type bracket with FRP dome and ball as per specification no. OH-PL/PBKT
Providing and erecting galvanised 1000mm double arm sword type bracket with FRP dome and ball as per specification no. OH-PL/PBKT
Supplying & erecting MS pole bracket for guarding/LT OH line, fabricated from angle iron 50x50x6mm and 1100mm long for necessary nos. of provided insulators, and erecting on pole with 50x6mm clamp complete as per specification no. OH -PL/BKT
Supplying and erecting G.I. pipe ‘C’ class ERW 25 mm dia with necessary fittings complete as per specification no.
Supplying and erecting G.I. pipe ‘C’ class ERW 50 mm dia with necessary fittings complet
Supplying and erecting pole clamp made from 50 x 6 mm MS flat for pole or pipe, post complete erected with 15 mm bolts and nuts, complete duly painted with one coat of red oxide and two coats of aluminium paint.
Providing earthing with galvanized iron earth plate size 60 x 60 x 0.6 cm complete with all materials, testing & recording the results as per specification no. EA-EP
Providing pipe type earthing with 40mm. dia. G.l. pipe or 20 mm dia. G.l. Rod complete with all materials as per specification no. EA-EP
Providing earthing with galvanized iron earth plate size 60 x 60 x 0.6 cm with funnel with a wire mesh for watering and brick masonry block C.l. cover complete with all materials, testing & recording the results as per
Making cement concrete foundation including excavation (60 x 60 x 150) cm deep in 1:3:6 cement concrete 20 x 25 mm stone metal, (45 x 45 x 45) cm /45 cm dia. x 45 cm height plinth duly plastered, with necessary curing and finishing complete. (above 6 m to 9 m poles)
Making M- 20 grade reinforced cement concrete foundation by considering the safe soil bearing capacity at site as 10 T/sq.m at 1.5 m depth including supply of steel, concrete, excavation and fixing provided nut bolts with the help of template, duly plastered as per design complete (for 9m & 10m high octagonal /conical GI pole)
Making M- 20 cement concrete foundation by considering the safe soil bearing capacity at site as 10 T/sq. m at 2 m depth including excavation and fixing provided nut bolts with the help of template, duly plastered as per design complete (for 12.5 m raising lowering high mast)
Painting of steel tubular / rail / RSJ pole above 6.0 m length along with street light pole brackets, clamps etc by scrapping the existing paint complete as per specification no CW -PTG/PTP.
Supplying, erecting & marking DPMCB 6A to 32A, C-series with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB
Supplying, erecting & marking DPMCB 6 A to 32 A B- series (for lighting) in provided distribution board as per specification no. SW-SWR/MCB
Supplying and erecting porcelain base iron clad cut out HC type 415V, 63A erected on polished wooden block.
Supplying and erecting porcelain base iron clad cut out HC type 415V, 100A erected on polished wooden block.
Supplying and erecting porcelain base iron clad cut out HC type 415V, 200A erected on polished wooden block
Supplying, erecting & marking TPMCB 40A to 63A, with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB
Supplying, erecting & marking FPMCB 40A to 63A, with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB
Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 2 core 10 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL
Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 4 core 10 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL
Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 4 core 16 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL
Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 4 core 35 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL
Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 4 core 70 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL
Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 3 core 4 sq. mm. copper conductor complete erected with glands & lugs, on wall/ trusses/ pole or laid in provided trench/ pipe as per specification no. CB-LT/CU
Supplying & erecting D.O.L Starter suitable for 415 V, 3 phase 50 cycles with no volt coil and overload element with necessary materials and connected to supply up to 7.5 H.P.
Supplying & erecting Fully Automatic Star/delta starter suitable for 12.5 H.P to 15 H.P. for 3 phase squirrel cage motor totally enclosed with overload and no volt relay complete erected on provided angle iron frame
Supplying & erecting FRP box of size 300mm x 200mm x 125 mm, 2.7 mm thick complete on pole/wall as per specification No. CB-SB
Supplying & erecting FRP box of size 250mm x 200mm x 100 mm, 2.7 mm thick complete on pole/wall as per specification No. CB-SB
Supplying and laying (including excavation of suitable width & depth up to 90 cm) 90 mm outside dia. double wall corrugated pipes (DWC) of HDPE for enclosing cable below ground/road surface, to required depth complete.
Supplying & erecting crimping type copper lugs for cable 25 sq. mm. complete as per specification no. CB-CL/CU
Supplying & erecting crimping type copper lugs for cable 120 sq. mm. complete as per specification no. CB-CL/CU
Supplying and erecting metal work in CRCA sheet including Iron work for supports with fabrication of boxes, panel boards, etc. including cutting, bending, drilling, welding, riveting, treated with anti-rust treatment and duly powder coated or painted with one coat of red lead paint and 2 coats of enamel paint complete.(Meter pannel box)
Point wiring for light/bell hybrid type (Surface type under false ceiling and concealed type for drops & switch boards on walls) in min 20 mm PVC conduit / casing n capping with 1.5 sq.mm. (2+1E) FRLSH grade copper wires, modular type switch, earthing and required accessories as per specification No: WGPW/HW
Point wiring for ceiling fan (Surface type under false ceiling and concealed type for drops & switch boards on walls) in min 20 mm PVC conduit / casing ncapping with 1.5 sq.mm. (2+1E) FRLSH grade copper wires, modular type switch, earthing and required accessories
Supplying and erecting mains with 2x2.5 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places. as per specification No: WG-MA/BW
Supplying and erecting modular type (two module) electronic step regulator for fan, duly erected on provided plate and box with wiring connections complete.
Supplying and erecting regular/ standard model ceiling fan of 1400mm. Sweep complete erected in position as per specification no. FG-FN/CF
Supplying and erecting bracket fan 400 mm. sweep A. C. 230 volts 50 cycles 1350 RPM. Oscillating type, plastic or metal blades chrome plated guard with speed regulator and moisture proof treatment to winding and with ‘E’ class insulation
Supplying and erecting exhaust fan medium duty 230 V A.C. 50 cycles 225mm. 1400 RPM with condenser complete erected in position with necessary materials. Fan motor with moisture proof treatment and ‘E’ class insulation.
Supplying and erecting integrated LED street light fitting 23 to 25W IP65 & IK08 class having single piece pressure die-cast aluminium housing, having system lumens output of Min. 2300 Lumens, min. efficacy of 100 lumen/W, CRI>70, CCT upto 6500K, THD<10%, p.f. >0.95, operating range of 140-270V, inbuilt surge protection of 10 kV, Life class of 50,000 Hrs. at L70B50, including driver complete with 3Years warranty as per specification No FG-ODF/FLS2.
Supplying and erecting integrated LED street light fitting 40 to 50W IP65 & IK08 class having single piece pressure die-cast aluminium housing, having system lumens output of Min. 4400 Lumens, min. efficacy of 110 lumen/W, CRI>70, CCT upto 6500K,THD<10%, p.f. >0.95, operating range of 140-270V, inbuilt surge protection of 10 kV, Life class of 50,000 Hrs. at L70B50, including driver complete with 3 Years warranty as per specification No FG-ODF/FLS2.
Supplying and erecting integrated LED street light fitting 70-75W IP65 & IK08 class having single piece pressure die-cast aluminium housing, having system lumens output of Min. 7700 Lumens, min. efficacy of 110 lumen/W, CRI>70, CCT upto 6500K,THD<10%, p.f. >0.95, operating range of 140-270V, inbuilt surge protection of 10 kV, Life class of 50,000 Hrs. at L70B50, including driver complete with 3 Years warranty as per specification No FG-ODF/FLS2.
Supplying and erecting integrated LED flood light fitting Max. 70W IP65 & IK07 class having pressure die-cast aluminium housing, having system lumens output of Min. 8400 Lumens, min. efficacy of 120 lumen/W, CRI>70, CCT upto 6500K, THD<10%, p.f. >0.90, operating range of 140-270V, inbuilt surge protection of 4 kV, Life class of 50,000 Hrs. at L70B50, including driver with U shaped bracket with 3 Years warranty as per specification No FG-ODF/FLS2.
Supplying and erecting integrated LED flood light fitting Max. 120W IP65 & IK07 class having pressure die-cast aluminium housing, having system lumens output of Min.14500 Lumens, min. efficacy of 120 lumen/W, CRI>70, CCT upto 6500K, THD<10%, p.f. >0.90, operating range of 140-270V, inbuilt surge protection of 4 kV, Life class of 50,000 Hrs. at L70B50, including driver with U shaped bracket with 3 Years warranty as per specification No FG-ODF/FLS2
Erecting departmentally supplied LED street light/ flood light fitting above 80 to 150W .
Supplying and erecting Street light bracket made from 40 mm. dia ‘B’ class G.I. Pipe, 0.6m. in length along with pole cap of 300 mm length and 80 mm dia duly welded with provided leads as per specification no. FG-BKT/BPC
Supplying and erecting electronic type Driver for Outdoor LED Fittings 46W- 75W suitable to operate on 230V A.C. 50 Hz. Having pf>0.95 and THD<10%.
Supplying and erecting electronic type Driver for Outdoor LED Fittings 151W- 200W suitable to operate on 230V A.C. 50 Hz. Having pf>0.95 and THD<10%.
Supplying and erecting T8 Fluorescent tube day light 600mm, 18 W
Supplying & erecting ready to use Retrofit T8 LED 18 / 20 tube light with polycarbonate body, heat sink, integrated HF electronic driver complete & compatible to T8 / T12 LED luminaire by disconnecting starter & ballast if necessary.
Supplying and erecting flush type shockproof plug socket 6A & 16A (6 pin) with 16A switch combined with indicator lamp and fuse with gang box on wooden board
Supplying and erecting modular type 32A, DP key tag switch with key tag, duly erected on provided plate and box with wiring connections complete
Supplying & erecting 18W, 230V integral type LED Lamp suitable for B-22 / E- 27 base
Supplying, installing, testing and commissioning of single phase, 230V, 50 Hz, 700VA digital pure sine wave inverter with backup time of ........ hrs. based on Insulated Gate Bipolar Transistor (IGBT) technology complete as per specification no. AP-INV
Supplying, installing, testing and commissioning of single phase, 230V, 50 Hz, 1400 to 1600VA digital pure sine wave inverter with backup time of ........ hrs. based on Insulated Gate Bipolar Transistor (IGBT) technology complete as per specification no. AP-INV
Supplying, erecting, testing and commissioning of single phase input & 1 phase output 1 kVA capacity online pure sine wave UPS, with backup time of ....... hrs. PWM & IGBT based, with 0.8 to unity output pf complete with all protections as per specification no. AP-UPS
Supplying and erecting 12V/200Ah tubular battery with battery terminal wire, duly charged with 36 months warranty complete
Supplying and erecting 12V/150Ah tubular battery with battery terminal wire, duly charged with 36 months warranty complete.
Providing servicing of 1/1.5/2/3 TR capacity split/window air conditioning unit with all necessary material. job includes checking of performance of unit, cleaning of filters of indoor unit, cleaning of outdoor unit with blower, checking of electrical connection of indoor as well as outdoor unit complete and submitting report to Engineer incharge.
Providing annual comprehensive maintenance contract for 1.5TR split/window air conditioning unit complete as per terms and conditions. Job includes 1) quarterly servicing 2) on call repair 3) replacement of all spares within 24 hours 4) sending standby manpower for VIP movement. The job exclude sheet metal work and plastic material
Providing brazing pipes and checking leakages in the split/window unit duly with dry nitrogen pressure, complete.
Providing replacement of unserviceable PCB for AC unit upto 3TR capacity
Supplying and erecting quartz electronic time switch having 24 hour dial to work on 250 V 50 cycle AC having built in rechargeable nickel cadmium batteries to run the time switch on failure of supply having switch contact rating up to 16A to use independently or in conjunction with contactor
Supplying and erecting four pole power contactor 430 V, 40 A for time switch complete erected on provided wooden block/ box, with necessary materials
Supplying and erecting programmable digital almanac timer microcontroller based with real time clock to operate on derived switching “ON” and switching “OFF” street light as per daily sunset and sunrise respectively automatically having 4 digit LED continuous time display, relay output 230 V / 10A with 10 hrs. battery backup and manual over drive facility capable to drive different capacity contactors timer erected in provided M.S. box
Supplying and erecting static energy meter with 240V 50 Hz. AC supply 10 to 60 A, ISI mark, accuracy class 1.0 with backlit LCD display, (measuring and display kWh, kVAh, V,I,PF, frequency, kW, kVA, six months history of Energy & MD in kW & kVA ) with transparent hinge type box complete erected on polished teak wood board duly wired with required size of weather proof PVC wires duly tested by electric supply company
Supplying & erecting crimping type aluminium lugs for cable 240 sq mm complete as per specification No. CB-CL/AL
Supplying and erecting all aluminium stranded conductors 7/2.21 mm. complete. (Gnat) (73.77kg/km) as per specification No. OH-CON/AAC
Supplying and erecting 3 phase 4 core 35 sq.mm. (3x35+1x25) Aerial bunched aluminium cable along with necessary accessories for LT distribution on provided LT pole as per specification no. OH-CBL/ABC
Supplying and erecting G.I. stay set for poles, including loop insulators at inaccessible height with anchor plate 300x300x6mm., straining screws, G.l. stay wire 7/10 SWG, G.l. stay rod 20mmx1.8m length and pole clamps duly erected in provided cement concrete foundation complete
Dismantling the existing pole above 6 m height with brackets, clamps, insulators, stay from the c.c. foundation and making the site clear by refilling the pits with excavated materials and bringing it to the ground level.
Supplying and erecting of isi mark insulation tape
Supplying and erecting of isi mark nutbolts
Supplying and erecting of isi mark tester
Supplying and erecting of isi mark led zero bulb
Supplying and erecting of isi mark led zero bulb holder
Supplying and erecting fault clearing on street light conductor
Supplying and erecting of AC servicing
Supplying and erecting of filter servicing
Supplying and erecting of batery servicing with water change
Supplying and erecting of RO membrane for filter
Supplying and erecting isi mark extension box
Rapid Power
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .