| 1 | 1₹15.4 LAccepted-AOC | 1 | Accepted-AOC Allotted | |
| 2 | 2₹16.1 L+₹74,131.50 (4.82%)Rejected-Finance AKS COLONY MC ZIRAKPUR | ZIRAKPUR | SAS NAGAR | PUNJAB | 2 | Rejected-Finance Rejected due to quoted higher rate |
Tender Value
₹14.2 L
EMD Value
₹28,500
Closing Date
1 Apr 2021, 12:00 pmClosed
Executive Engineer
Water Treatment Plant Dashmesh Academy Road
Providing and installing a new tubewell of size 200 mm id straight up to 200 mtr. Depth Under Head PRWSSIP 1A iiJJM
2021_WB_60638_1
DWSS-W-DIV23-8866-1
Open Tender
Civil Works
Item Wise
90 days
Tedhewal
Please refer Tender documents.
4 documents required · 4 mandatory
₹1,000
₹28,500
3 Nov 2021
26 Feb 2021
1 Apr 2021
26 Feb 2021
1 Apr 2021
26 Feb 2021
Amount
TUBEWELL
"Providing and installing 200 mm i/d straight tubewell drilling of 500 mm (20") of suitable size borehole where in stony strata/boulders are some times encounted in this area while dirlling which makes drilling purely by Reverse rotary/any suitable Rig mehtod immpossible. While mostly is done by Reverse rotary method, but when stony/boulder strata appear, then other methods i.e. direct rotary etc. are used. So drilling by any suitable rig in this area including the cost of consumable store fuel, oil & transportation of rig to the site of proposed bore. Complete in all respect upto full depth (0 to 200 mtr depth BGL). 1. Erection and dismantliing of boring plant including all arrangement for the transportation of the boring equipment to site of work from the store of contractor at site and back are to be made by the contractor at his own cost. All rates should be quoted for supplying the material at site of work . Pits for collection of water and water for drilling tubewell be arranged by the firm / contractor at site at his own cost. 2. In case the bore is converted into a tubewell payment of bore shall be made up to the bail plug plus margin (7% of main bore drilling or as actual as per field requirement whichever is less) required for sustaining the main bore. The test bore beyond margin shall be paid at the rate of test bore drilling"
Supplying & lowering MS Pipe as per IS 4270-2001 including MS sockets having dimensions as per IS code duly welded with MS electrode to have extra strenght to lower the pipe into tubewell bore.
200mm nominal diameter (weight 33.6 kg per metre) 6.4mm thickness
Supplying, lowering of Stainless Steel Cage type wire wound screen as per IS:8110-2000 or latest ISI Marked,duly welded with suitable grade S.S welding electrode to lower the strainer into tubewell bore.
200mm Steel Strainer (slot size 0.75mm) 6.30 mm thickness. As per new guidliness.
Supplying and fixing of bail plug of M.S. Pipe complete with inverted U-hook attached to the bottom plug complete in all respects.
200mm internal diameter (Weight 33.6 kg per meter) 6.40 mm thickness.
Supplying & fixing mild steel centering guides made out of 32mm x 6mm thick M.S. bar complete in all respects.
Supplying and fixing of well cap having threads to fix on housing pipe complete in all respects.
200mm internal diameter
Supplying and fixing M.S. Clamps of size 150mm x 12mm made out of MS Flat 1.52m long, suitable to fit Housing Pipe including the cost Nut & Bolts of Suitable size complete in all respects.
Supplying, fixing and lowering of stainless steel socket as per IS 8110: 2000 or latest, ISI marked duly welded with suitable grade SS welding electrode to lower the strainer into tubewell bore complete in all respects.
200mm internal diameter
Supplying, lowering & fixing of M.S Special socket to connect S.S Strainer to M.S Pipe duly welded with suitable grade welding electrode complete in all respect.
200mm internal diameter
Supplying at site wooden box of suitable size with Lid & lockign arrangement for preserving strata sample collected from the bore.
Supplying at quarry site of gravel of 1/16" to 1/8" sizes including pouring and packing in the annular space between the pipe assembly and the bore. The gravel should be free from, dust, dirt, or the vegetable manner as per IS 4097/1967 with latest amendments (to be paid as per actual length of pipe)
Development and stabilizing of the tubewell with Air compressor or required capacity as directed by the engineer-in-charge including cost of tools, appliances & consumable to the satisfaction of Engineer-in-charge.
Capacity of Air Compressor 550 cfm at 600 PSI
Development and stabilizing of the tubewell with submersible pump of required capacity as directed by the engineer-in-charge including cost of tools, appliances & consumable to the satisfaction of Engineer-in-charge.
Collection of water sample from different strata and testing of sample from approved laboratory (Physical & chemical Analysis)
Testing of water sample for Heavy metal from approved laboratory (Toxic material such as Arsenic, lead, mercury, pesticide and uranium etc.)
Making electric Logging of borehole with electronic well logger including cost of equipment at site etc.complete in all respect
Supplying at site Tibba sand etc. including pouring and packing in the annular space between the pipes assembly and the bore above clay seal complete in all respect. (Up to 60 mtr.)
Providing & Fixing Clay seal in graval pack minimum 3 Mtr. (As per BIS 2800-2019)
Providing & Fixing Sanitery Seal (As per BIS 2800-2019)
Earth,Surkhi, Sand, Earth, Fly Ash, Bajri, allast, Stone Boulders, Kankar and Building Rubbish, Earth. 6.0 km to 30.00 km
Sterilization of Well (As per BIS 2800-2019)
jasbir industries
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .