Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹3.6 CrAccepted-AOC | ₹3.6 Cr Quoted ₹4.1 Cr | L1 | Accepted-AOC L1 bidder |
| 2 | L2₹4.2 Cr+₹15.5 L (3.79%)Rejected-Finance | ₹4.2 Cr+₹15.5 L (3.79%) | L2 | Rejected-Finance Higher than L1 bidder |
| 3 | Rejected-Technical 10TH MILE RISHI ROAD KALIMPONG DISTRICT DARJEELING PIN 734301 | KALIMPONG | DARJEELING | WEST BENGAL | 734301 | - | - | Rejected-Technical Class of contractor not meet as per NIT |
| 4 | Rejected-Technical | - | - | Rejected-Technical Class of contractor not meet as per NIT |
| 5 | Rejected-Technical | - | - | Rejected-Technical Class of contractor not meet as per NIT |
Tender Value
₹1.5 Cr
EMD Value
₹4.3 L
Closing Date
7 Oct 2023, 6:00 pmClosed
CWE
HQ 136 WORKS ENGINEERS PIN - 914136 C/O 99 APO
COMPLETION OF INCOMPLETE WORK OF CONSTRUCTION OF KV SCHOOL AT KALIMPONG MIL STATION
2023_MES_615310_1
CWE/136-WE/34 OF 2023-24
Open Tender
Civil Works - Canal
Lump-sum
364 days
Kalimpong
Class B, Category a(I)
9 documents required · 9 mandatory
₹2,000
GE 867 EWS
₹4.3 L
Yes
1 May 2024
24 Aug 2023
9 Oct 2023
24 Aug 2023
7 Oct 2023
30 Sept 2023
24 Aug 2023 - 7 Sept 2023
Amount
BUILDING WORKS
Lump sum price worked out by the Contractor for “(BUILDING WORKS)” as listed in Schedule ‘A’ Part-I. Representing ** ___ % ______ percent *Above / Below the lump sum price of Rs 11,45,000.00 inserted by the MES in Schedule ‘A’ Part-I
SITE CLEARANCE AND AREA DEVELOPMENT
Lump sum price worked out by the Contractor for “ SITE CLEARANCE AND AREA DEVELOPMENT ” as listed in Schedule ‘A’ Part- II. Representing ** ___ % ______ percent *Above / Below the lump sum price of Rs 0.00 inserted by the MES in Schedule ‘A’ Part-II
INTERNAL WATER SUPPLY
Lump sum price worked out by the Contractor for “(INTERNAL WATER SUPPLY)” as listed in Schedule ‘A’ Part- III. Representing ** ___ % ______ percent *Above / Below the lump sum price of Rs 1,26,711.62 inserted by the MES in Schedule ‘A’ Part-III
INTERNAL ELECTRIFICATION
Lump sum price worked out by the Contractor for “(INTERNAL ELECTRIFICATION)” as listed in Schedule ‘A’ Part- IV. Representing ** ___ % ______ percent *Above / Below the lump sum price of Rs 3,55,703.32 inserted by the MES in Schedule ‘A’ Part-IV
INTERNAL ELECTRIFICATION (Misc Items) Sch A Part IV(A)
Supply & fixing 4'' surface/wall mounted LED batten 20 Watt CCT-6500K, system output lumennot less than 2000lm, extruded aluminium housing with high quality Polycarbonate diffuser, wide voltage protection range 140V-270V. Make : Philips model - Smatbrite Batten, BN021C LED 20S PSU CW GR S2 or equivalent in Havells/Surya including connecting up with 3.0 core, 0.5 Sq mm copper conductor sheathed as specified and directed. M/s Jyoti Enterprises, Sevoke Road, Siliguri - 734001 Invoice No J -1175/21-22 dt 10 May 2021, Ser No 01.
Supply and fixing LED (building ) security light should have presure die cast Aluminium housing and lens embedded PC cover having top opening separate driver compartment, IP protection should be IP 66. And impact ressistance of IK 07 system power consumption ( Including Driver losses) should not exceed 20W . Input voltage range 120-277 VAC . Make : Havells ENDURA PEARL, Cat Part No ENDURAPEARLSL20WLED 757SASYTOPC including bracket made out of 25mm dia light grade GI Pipe not less than 1.2 mtr ling bend to shape duly fixed with MS clamps, nut, bolts etc including connecting up with 3.0 core , 1.5 sqmm copper conductor sheathed complete all as specified and as directed. M/s Jyoti Enterprises, Sevoke road, Siliguri-734001 Invoice no J-1173/21-22 dt 10 May 2021' Ser No 15
Supply & Fixing exhaust fan with louvers 300 mm sweep, not less than 4 star rated 900/950 RPM, ISI marked, single phase, 240 Volts, AC, 50 Hz and connecting up complete including louvers and provision of cable 3 core of size 0.5 Sqmm (16/0.2 mm) from ceiling rose to fan complete all as specified and as directed. Make :- CG/Havells/ or equivalent approved make
S&F ceiling fan 1400 mm sweep, ISI marked, not less than 4 star rated single phase, 50Hz, AC complete with canopy, down rod, blade, motor etc without regulator and connecting up complete including provision of cable 3 core of size 0.5 sqmm (16/0.2 mm) from ceiling rose to fan complete all as specified and as directed. Note :- Fan regulator shall be measured and paid separately
S&F compact building security light luminaire 1x25 watt CFL with MS housing with epoxy powder coated with acrylic cover with suitable CFL lamp including bracket made out of 40 mm light grade GI pipe ISI marked not less than 1.2 mtr length bend to shape etc duly fixed with MS clamps nut, bolts etc complete all as specified and as directed. Make :- Model SCE1320DF of CG or equivalent make of Philips/Havells
Supply & Fixing light fitting, for 150 watt MH lamp, complete with ballast and capacitor comprising of sheet aluminium housing, with cast aluminium pipe mounting arrangement of aluminium reflectors, a highly transparent clear acrylic cover hinged to the canopy at one end and fixed by means of single spring action at the other, suitable including bracket with 50mm dia. ISI marked G.I. pipe minimum 1.2 metre on pole / building 01 No MH 150 watts fixing of lamp all as specified and as directed. Make :- Model MHSGN1215H/F-G-E27 of CG or equivalent make of Philips/Havells
S & F MCB Distribution Boards TPN 4 way, 415 Volts, 50 Hz, AC, double door vertical type with locking arrangement including lock and key and 100 Amps copper bus bar, shrouded neutral links, earthing with 01 No MCCB TPN 63 Amps 16 KA as incoming and without MCBs as specified and directed.
S & F MCB Single Pole of 240 Volts, AC, 50 Hz of capacity 5-30 Amp 10 KA complete all as specified and directed
S & F MCB Single Pole of 240 Volts, AC, 50 Hz of capacity 30-40 Amp 10 KA complete all as specified and directed
S & F MCB SPN of 240 Volts, AC, 50 Hz of capacity 20/25 Amp 10 KA complete all as specified and directed
S & F MCB TPN of 240 Volts, AC, 50 Hz of capacity 25/32 Amp 10 KA complete all as specified and directed.
S & F MCB TPN of 240 Volts, AC, 50 Hz of capacity 40 Amp 10 KA complete all as specified and directed.
Supply, Installation, commissioning and testing including connection of cubical type LT indoor factory made CPRI type tested LT Panel 415 Volts, Cable alley, with individual compartment for MCCB/MCB, side hinged front openable doors with lock and key with screwed knobs for shutter for each component, bending of edges of front cover with providing suitable rubber/neoprene gaskets at edges, protection class IP 54 as per IS 5039 of suitable size, dust and vermin proof fabricated out of CRCA Sheet 2 mm thick and frame of angle iron of suitable size duly welded including cable entry & exist through glands including two coats of powder coated over a coat of primer on both outer and inner surfaces of panel, internal connection from bus bar to switchgear/MCCB with suitable size of solid copper bus bar jumpers etc all as specified and as directed including following items all as specified and as directed:- BUSBAR : Copper bus bar suitable for 3 phase for wire system of capacity with 200 Amps for RYB and 100 Amps rating for N INCOMING :- (i) MCCB 4 Pole 160 Amps breaking capacity 25 KA thermal magnetic setting 415 Volt, 50 Hz, AC - 01 (ii) Indicator lamp LED Type RYB - 01 Set. Item continued as serial no.6.40
B. OUTGOING :-(i) MCCB 3 pole of capacity 63 Amps,16 KA, 415 volt, 50 Hz, AC - 01 No. (ii) MCCB TPN of capacity 63 Amps,16 KA, 415 volt, 50 Hz, AC - 01 No. (iii) MCB TPN, 40 Amps,of breaking capacity 10 KA, AC 415 V - 02 Nos (iv) MCB SP 20 A, 230 Volts, 50 Hz, AC-01 No (v) Spare space for fixing of 01 No MCB TPN
Supply, Installation, commissioning and testing including connection of cubical type LT indoor factory made CPRI type tested LT Panel 415 Volts, Cable alley, with individual compartment for MCCB/MCB, side hinged front openable doors with lock and key with screwed knobs for shutter for each component, bending of edges of front cover with providing suitable rubber/neoprene gaskets at edges, protection class IP 54 as per IS 5039 of suitable size, dust and vermin proof fabricated out of CRCA Sheet 2 mm thick and frame of angle iron of suitable size duly welded including cable entry & exist through glands including two coats of powder coated over a coat of primer on both outer and inner surfaces of panel, internal connection from bus bar to switchgear/MCCB with suitable size of solid copper bus bar jumpers etc all as specified and as directed including following items all as specified and as directed:- BUSBAR : Copper bus bar suitable for 3 phase for wire system of capacity with 150 Amps for RYB and 75 Amps rating for N INCOMING:-(i) MCCB TPN, 63 Amps, breaking capacity 16 KA, 415 Volt, 50 Hz, AC - 01 (ii) Indicator lamp LED Type RYB - 01 Set. B. OUTGOING :-(i) MCCB 3 pole of capacity 63 Amps,16 KA, 415 volt, 50 Hz, AC - 01 No. (ii) MCB TP, 63 Amps,of breaking capacity 10 KA, AC, 415 V - 01 No (iii) MCB SP 30-40 Amps, 230 Volts, 50 Hz, AC-02 Nos (iv) Spare space for fixing of 01 No MCB TPN (v) Spare space for fixing of 01 No MCB SP
SUB TOTAL
EXTERNAL WATER SUPPLY
Lump sum price worked out by the Contractor for “(EXTERNAL WATER SUPPLY)” as listed in Schedule ‘A’ Section V ( Part- V). Representing ** ___ % ______ percent *Above / Below the lump sum price of Rs 5,07,779.35 inserted by the MES in Schedule ‘A’ Section V (PART-V)
EXTERNAL WATER SUPPLY (Misc Items) Sch A Part V(A)
Provn of masonry valve pit of internal size 900 mm x 900 mm x 900 mm with 4mm thick MS sheet cover angle iron frame and locking arrangements including two coats of red oxide primer on steel surface as directed by Engr-in-charge.
Supply and fixing of bulk water meter, horizontal type, 80 mm dia, Class B, flanged end, operating pressure max 16 Bar, maximum temperature 500 C, conforming to relevant IS including all fixing arrangements for fixing the meter in the 80 mm GI pipe line complete all as specified and as directed
M & L cutting existing 100 mm dia GI pipe line and inserting of new Tee branch of size 80 mm incuding necessary earth work, fittings such as nipple,socket,union etc complete all as specified and as directed
SUB TOTAL
EXTERNAL ELECTRIFICATION
Lump sum price worked out by the Contractor for “(EXTERNAL ELECTRIFICATION)” as listed in Schedule ‘A’ Part- VI. Representing ** ___ % ______ percent *Above / Below the lump sum price of Rs 6,26,428.99 inserted by the MES in Schedule ‘A’ Part-VI
EXTERNAL ELECTRIFICATION (Misc Items) Sch A Part VI(A)
S & F cable route marker made up of PCC block and properly painted as per approved colour (1:3:6) type. C-1 using 20mm graded stone aggregated. Size 900 mm x 300mm x 100 mm thick. (45 Cm burried in ground) with DANGER/11KV CABLE/MES on route marker including excavation and earth work complete all as specified and as directed.
S & F cable route marker of size 100 mm x 100mm x 5 mm thick GI plate with inspection thereon bolted/ welded to 35 mm x 35 mm x 6 mm angle iron 60 cm long and fixing the same in ground as required for LT cable complete all as specified and as directed.
Supply, testing and commissioning of XLPE HT cable , insulated, screended, PVC bedded, galvanised steel strip or wire armoured, electic power cable (heavy duty) with aluminium conductor, conforming to IS : 7098 (Part II), 11 KV "E" grade, ISI marked in drum, cross sectional area 95 Sqmm, 3 core laid in pipe/ducts/ trenches/ under floor/ under road/ poles etc all as specified and as directed. Note :- Excavation and earth work, sand cushion, PCC cover and protection pipe shall be measured and paid separately in respective items.
Supply, laying, testing, commissioning of cable XLPE insulated armoured heavy duty electric cable including end termination with necessary cable glands, lugs etc in trenches/ poles/ walls through pipes etc conforming to IS 7098-1985, ISI Marked (1100V grade) with multistranded aluminiuim conductor, cross sectional area 120 Sqmm 3.5 Core complete all as specified and as directed.
Supply, laying, testing, commissioning of cable XLPE insulated armoured heavy duty electric cable including end termination with necessary cable glands, lugs etc in trenches/ poles/ walls through pipes etc conforming to IS 7098-1985, ISI Marked (1100V grade) with multistranded aluminiuim conductor, cross sectional area 95 Sqmm 3.5 Core complete all as specified and as directed.
Supply, laying, testing, commissioning of cable XLPE insulated armoured heavy duty electric cable including end termination with necessary cable glands, lugs etc in trenches/ poles/ walls through pipes etc conforming to IS 7098-1985, ISI Marked (1100V grade) with multistranded aluminiuim conductor, cross sectional area 70 Sqmm 3.5 Core complete all as specified and as directed.
Supply, laying, testing, commissioning of cable XLPE insulated armoured heavy duty electric cable including end termination with necessary cable glands, lugs etc in trenches/ poles/ walls through pipes etc conforming to IS 7098-1985, ISI Marked (1100V grade) with multistranded aluminiuim conductor, cross sectional area 16 Sqmm 2 Core complete all as specified and as directed.
Supply and fixing energy efficient street light fittings suitable for 4 x 24 watt T-5 fluorescent lamp complete with 04 Nos 24 watt T-5 lamp, lamp holder, reflector, acrylic cover, electronic ballast, medium grade 40 mm dia GI pipe ISI marked bracket not more than 1.2 mtr long duly bend to shape and fixed with 4 mm thick MS Clamps including necessary nuts & bolts etc and fixed to steel tubular pole including electrical connection complete from terminal box to fitting all as specified and as directed. Note :- Electrical connection from terminal box to light fitting shall be measured and paid separately.
Supply & Fixing street light fitting, for 250 watt Metal Halide lamp, complete with ballast and capacitor comprising of cast aluminium housing, a pair of aluminium reflectors, a highly transparent clear acrylic cover hinged to the canopy at one end and fixed by means of single spring action at the other, suitable for mounting on 50 mm dia GI Pipe medium grade ISI marked minimum 1.2 metre fixed on walls/pole with necessary fixing arrangement made out of MS plate duly painted with suitable nuts, bolts etc and including 01 No 250 watt fixing of lamp all as specified and as directed. Make :- MHSSG1225IH/FG (COMPLETE) of CG or equivalent of Philips/Havells
S&F Junction box made out 3.15 mm CRCA Sheet of suitable size duly painted and fixed with suitable MS Clamps of 4.00 mm thick including nuts, bolts etc - 02 Nos Aluminium Bus bar / bus bar support, 50 A, Single Phase duly insulated and fixed for terminating single phase UG Cable 16 Sq mm 2 core including glands etc with 01 No, MCB SP, 10 Amps, 10 KA rupturing capacity for pole height all as specified and directed.
(f) Multi function meter class 1.0, 5A, 3 Phase,with LED display flush mounting panel type Model 'A' of L&T WDM 303 FDWAI or equivalent approved make (g) Control wiring with PVC insulated unsheathed copper conductor ISI marked with control/protection Out going:-(a) MCCB 3 pole 160 Amps capacity, 25 KA breaking capacity adjustable type - 01 No (b) MCCB 3 pole 100 Amps capacity, 16 KA breaking capacity - 01 No (c) MCCB TPN 63 Amps capacity, 16 KA breaking capacity- 01 No (d) MCB Single pole and neutral (SPN) 30 Amps capacity, 10 KA breaking capacity - 01 No (e) MCB TPN 32 Amps, 415 Volts, 10 KA - 01 No as outgoing for street light control panel
Supply and fixing of Street light control panel made out of 3.15 mm thickness CRCA sheet totally enclosed conforming to relevant IS/IEC, CPRI type tested, duly powder coated comprising the following :- (a) 01 No MCB SPN 30 Amps, 415 Volts, AC, 50 Hz, 10 KA ruputuring capacity as incoming (b) Power contactor 3 Pole, AC, 3 rating, 25 Amps coil voltage 240 Volts - 01 No (c) Timer clock type for controlling the street light, single phase, 10 KA 230 Volts AC (d) Indicator lamps - 01 Set for On & Off (e) Control wiring for automatic operation of street lights with by pass arrangement all as specified and as directed. Note :- Item to be fixed in the motor control panel under Fire fighting schedule
SUB TOTAL
PROTECTIVE WORK
Lump sum price worked out by the Contractor for “(PROTECTIVE WORK)” as listed in Schedule ‘A’ Part- VII. Representing ** ___ % ______ percent *Above / Below the lump sum price of Rs 36,04,705.25 inserted by the MES in Schedule ‘A’ Part-VII
SEWAGE DISPOSAL
Lump sum price worked out by the Contractor for “(SEWAGE DISPOSAL)” as listed in Schedule ‘A’ Part- VIII. Representing ** ___ % ______ percent *Above / Below the lump sum price of Rs 2,42,501.24 inserted by the MES in Schedule ‘A’ Part-VIII
AREA DRAINAGE
Lump sum price worked out by the Contractor for “(AREA DRAINAGE)” as listed in Schedule ‘A’ Part- IX. Representing ** ___ % ______ percent *Above / Below the lump sum price of Rs 91,617.71 inserted by the MES in Schedule ‘A’ Part-IX
COMPOUND WALL, FENCING & GATE
Lump sum price worked out by the Contractor for “(COMPOUND WALL, FENCING & GATE)” as listed in Schedule ‘A’ Part- X. Representing ** ___ % ______ percent *Above / Below the lump sum price of Rs 11,26,285.24 inserted by the MES in Schedule ‘A’ Part-X
FIRE FIGHTING SYSTEM
Lump sum price worked out by the Contractor for “(FIRE FIGHTING SYSTEM )” as listed in Schedule ‘A’ Part- XI. Representing ** ___ % ______ percent *Above / Below the lump sum price of Rs 8,08,382.88 inserted by the MES in Schedule ‘A’ Part-XI
FIRE FIGHTING SYSTEM (Misc Items) Sch A Part XI(A)
Supply, Jointing and laying in trenches, in standard length, centrifugally cast (spun) ductile iron (DI) pressure pipes,with inside cement mortar lining and black bitumen external coating, nominal diameter 150 mm bore, class K-9 classification, conforming to IS-8329 ISI marked, including push on type rubber joint, testings, complete all as specified and as directed Note : DI specials will be measured and paid separately under relevent item of Schedule
Supply, Jointing and laying in trenches, in standard length, centrifugally cast (spun) ductile iron (DI) pressure pipes,with inside cement mortar lining and black bitumen external coating, nominal diameter 100 mm bore, class K-9 classification, conforming to IS-8329 ISI marked, including push on type rubber joint etc including testings, complete all as specified and as directed Note : DI specials will be measured and paid separately under relevent item of Schedule
Supply, Jointing and laying in trenches, in standard length, centrifugally cast (spun) ductile iron (DI) pressure pipes,with inside cement mortar lining and black bitumen external coating, nominal diameter 80 mm bore, class K-9 classification, conforming to IS-8329 ISI marked, including push on and rubber gasket, and necessary DI specials etc including testings, complete all as specified for the following dia of pipe. Note : DI specials/ fittings will be measured and paid separately under relevent item of Schedule
M&L for bend (any type radius and angle) tapers any type fittings ISI marked of size 150 mm for DI pipes class K-9,with inside cement mortar lining and black bitumen external coating, such as bends, tapers, tee pieces, single branches, Y junctions, Double junctions, connecting pieces, Nuts & bolts, Gaskets, Flanges etc. all as specified and as directed.
M&L for bend (any type radius and angle) tapers any type fittings ISI marked of size 100 mm for DI pipes of class K9 ,with inside cement mortar lining and black bitumen external coating, such as bends, tapers, tee pieces, single branches, Y junctions, Double junctions, connecting pieces, Nuts & bolts, Gaskets, Flanges etc. all as specified and as directed.
M&L for bend (any type radius and angle) tapers any type fittings ISI marked of size 80 mm for DI pipes of class K-9, with inside cement mortar lining and black bitumen external coating, such as bends, tapers, tee pieces, single branches, Y junctions, Double junctions, connecting pieces, Nuts & bolts, Gaskets, Flanges etc. all as specified and as directed.
Supply and fixing cast iron air release valve conforming to IS- 14845 with two air out lets 50mm bore and fixing up in cast iron/DI pipe of any size 100/80mm water supply mains including all jointing materials as required at site and all as directed and testing complete.
Supply and install testing and commissioning monoblock pump set with bronze impeller, directly coupled with motor, minimum total head 20 meter and discharge min 1350 LPM (Not less than 10HP,high speed, prime mover) operated on 3 phase, AC, 415 Volts, 50 Hz. The motor casing shall be of cast iron, pump shaft/ motor shaft shall be of stainless steel, pump bowls shall be of high graded cast etc. including necessary fixing arrangement in the roof of the building, including electrical connections suction strainer and suction, delivery water connections complete all as specified and as directed. The pump and motor shall comply to all the requirements of relevant IS. (01 No working & 01 Stand by) all as specified and as directed.The make of pumpset shall be of model No KDS 1030 ++ of Kirloskar or equivalant approved make in CG/KSB. Note :- (i) PVC insulated copper conductor and startor, suction and delivery pipes will be measured and paid separately. (ii) Any thing missed out for efficient operation of pump set as per manufacturer recommendation is deemed to be included in the rate quoted
(f) Control wiring with PVC insulated unsheathed copper conductor ISI marked with control/protection for automatic operation of pumpset to maintain positive pressure in the fire hydrants and operation of siren etc. all as directed. OUTGOING:- (i) MCB TPN, 415 volts, 50 Hz, 10 KA, breaking capacity rating 32 Amps - 03 Nos (For fire pump & 01 Spare) (ii) MCB TPN, 415 volts, 50 Hz, 10 KA, breaking capacity rating 16 Amps - 01 No (For Siren) (iii) Star delta startor fully automatic suitable for 7.5 HP 3 phase AC 3 rating 415 volts 50 Hz AC complete conforms to relevent IS/IEC including necessary power contactors on off push button, over load protection,single phase preventor, under volts protection etc complete with SS enclosure - 2 Nos (iv) Provision for fixing 1 No startar for siren (v) Startor DOL 3 phase 430 Volts AC suitable for 5 HP siren including over load/ under voltage protection, single phase preventor, SS enclosure etc - 1 Nos Note : The rate quoted for item no above deemed to be for automatic operation inclusive of wiring with pressure switch/motor startor/operation of siren etc for operation of fire pump at a pre set pressure.
Supply & fix fire hydrant landing valve type A specification of 63 mm dia inlet flanged suitable for 80 mm and out let 63 mm with female instantaneous out let with end cap of size conforming to IS 5290 complete ISI marked all as specified and as directed
M&L Fire brigade inlet connection 3 way for the risers shall have two instantaneous pattern of 63 mm dia valve, complte with non return valve, manifold etc mounted in a suitable MS enclosure with glass fronted lockable doors complete all as specified and as directed
Supply and fix brass nozzle for 20 mm dia hose pipe reel conforming to IS 8090 complete all as specified and as directed
Supply and fix branch pipe with suitable gun metal valve of size 20 mm with fixing arrangements for hose reel of 20 mm dia complete all as specified and as directed
Supply, fix, test and commessioning for electric motor siren conforming to IS 1941 suitable for 3 phase, 415 V, 50 Hz, AC supply with motor not exceeding 3.75 KW power and able to deliver 143 dB noise level. Siren will have a automatic equipment for producing a warbling note complete including necessary fixing arrangement, elecrical connections, weather proof enclosure made out of MS angle/ sheets/ flat duly painted on the roof of building etc all as specified and as directed. Note: Startor will be measured and paid seperately.
Supply, laying, testing, commissioning including end termination with necessary cable glands, lugs etc of cable XLPE insulated armoured heavy duty electric cable conforming to IS 7098-1985, ISI Marked (1100V grade) with multistranded aluminiuim conductor, cross sectional area 25 Sqmm 4 Core complete through tranches/pipe/floor/roof/walls etc. all as specified and as directed.
Submerssible cable/ Copper cable 3 core multi stranded copper conductor PVC insulated sheathed, water proof, ISI marked of size 6 sqmm for connecting from starter to fire pump and sump pump centrifugal type pump sets all as specified and as directed Note :- Pipe protection for submerssible cable shall be measured and paid separately.
Supply install testing and commissioning Silent type Diesel Engine Generating set 415 volts 30 KVA/ nearest higher size available KVA, 3 phase 0.8 power factor, 50 Hz, 1500 RPM self exicited self regulated brushless AC generator installed including acoustic enclosure suitable for ambient condition at Kalimpong and confirming to condition under IS 10002, 13364 Part I 1992, BS 5514/5000 with following: (i) The capacity of Generator set shall be net after all due derating factors as per relevant IS/BS Standards design. (A). Alternator :- Standard design alternator rated at 30 KVA/ nearest higher available capacity at 0.8 (lag) power factor AC, 3 - phase 4 - wire 415 volts 50 Hz, 1500 RPM, self exicited self regulated screen protected drip proof brushless design with winding in pole faces, insulating class 'H' and voltage regulation of + 1% at rated voltage from no load to full load. The alternator shall be confirming to BS 5000, IS: 13364 Part I (1992) and shall be in position to generate supply with frequecy regulation with in + 1% tolerance. The alternator will be suitable for tropical climate and shall generally confirm to BS - 2613/5000/ IS - 4722. i) Insualation class - 'H' ii) Temparature rise Class - 'H' iii) Excitation : Self Excited iv) Regulation performance: The voltage is kept constant with + 1%. v) Frequency regulation + 1% Item continued as serial no 18.90
(B) Diesel Engine: - Adquate capacity of Diesel engine water cooled to drive independently above alternator and after considering de-rating as per site conditons after generating and reducing power consumed by accessories directly coupled through flexible coupling multi cylinder multi stroke direct injection, cold starting 1500 RPM, as per relevant IS/BS complete with standard accessories all as specified and required for safe handling and operation salient features of accessories shall be as under:- i) Fly wheel with housing ii) Cooling system :- Moulded radiator with fan & belts. iii) Cooling Water pump : - Centrifugal type belt driven. iv) Exhaust System :- Exhaust System complete with exhaust piping of suitable dia with MS pipe medium grade. Turbo charger type Exhaust manifold Silencer : Residential type v) Fuel System :- Fuel injection system with fuel injectors, fuel injection solenoid switch controlled by governer electronic operated/ (as recommended by OEM) for 1% speed /frequecy regulation. Fuel filters Fuel hoses vi) Lub oil System :- Item continued as serial no 19.00
Lubricating oil filter Lubricating oil pump vii) Air Intake System :- Air intake Manifold Air cleaner dry type viii) Governer electronic type ix) Starting System :- Electric Self starter with and including battary charging alternator 12 Volts DC. x) Batteries :- Batteries of maintenance free of capacity 12 V, 150 AH- 01 No complete with copper conductor multistranded leads of suitable length from self starter to the battary terminals complete with initial charge and initial fill of electrolyte all as specified. Start and stop push button Ignition key / Switch Radiator with blower fan & first fill of coolant oil Corrosion inhibitor coolant Direct fuel injection system through governer electronic type xi) Generator Monitoring Panel : - Comprising of all standard items as per standard manufacturing, iginiton key switch and start / stop arrangement, indications for Engine parametes, hour run meter, RPM meter, Engine oil pressure indicator, water/coolant temperature indicator, Battery volt display. Item continued as serial no 19.10
xii) Safety Controls : - Engine low lube oil pressure high water temperature and over speeding of engine. xiii) Coupling arrngement : - Flexible coupling xiv) Accessories :- AVM Pads built- in or separtely mounted to manufactrer base frames. xv) Base Frame : - Made out of ISMC of sturdy design made of MS channel with necessary reinforcement and predetermined holes as per manufacturer. xvi) Fuel Tank :- Daily service fuel tank made complete on a common base inside the acoustic enclosure as per manufacturer guidelines for min 8 hrs continuous operation. xvii) MS/Steel flexible pipe line to and from the fuel tank to the DG Set. xviii) Battery Charger shall be provided as per manufacturer guidelines xix) The DG Set shall comply to the emission limits requirement as per Govt of India, Gazette notification No bearing No 595 dated 11 Dec 2013 and No 167 dated 31 Mar 2014. The DG Set shall be complied with all test requirements as stipulated in the gazette notification. All relevant test results from NABL accredited lab shall be produced to GE. C) Civil Works :- Item continued as serial no 19.20
All civil works including PCC plat form and related foundations including for panel and equipments including making good of distrubed area during installation and commissioning of genset. The depth and size of the foundation and PCC as recommended by the manufacturer. Note:- The contractor shall arrange for artificial load for testing of DG Set at site and the cost is deemed to be included in the above offer. D) Acoustic Enclosure:- Manufactured by OEM suitable for 30 KVA DG Set. (i) Tested by NABL approved lab as per CPCB (ii) It Should be as per latest rules and regulations of Ministry of Environment and Forest and Pollution control board. (iii) The generating set battery should be inside the enclosure. (iv) Fuel tank should be inside the enclosure, however, the fuel storage shall be enough for 8 hrs continuous operation. If required contract may arrange outside fuel storage capacity to achieve this (v) Construction Details/specification are as follows : - a) Outer body :- CRCA Sheet of 1.6mm thick. b) Doors :- CRCA sheet of 1.6 mm thick c) Sound Insulation :- 100 mm thick rock wool(minimum density 64kg/Cum)/ fire resistance foam/puff as per OEM/ as per standard manufacturing to achieve desired decibel level Item continued as serial no 19.30
vi) The acoustic should be composite in construction and fully assembled integral unit. vii) The DG Set should be provided with external Emergency stop push button. viii) The enclosure should be suitably internally illuminated by CFL/FTL Lamp fittings. ix) The noise level should be 75 dB at 1m under free field conditions. x) The acoustic enclosure parts shall be of powder coated after pre treatment process. The base frame should be painted with epoxy based black shade. Note :- (i) The complete DG Set shall be procured from authorised OEM of the manufacturer of engine. A certificate in this connection shall be submitted to the GE. (ii) Circulation system to achieve desired inside temperature of acoustic enclosure, if required shall be provided as per OEM recommendation. (iii) The quoted rate shall be deemed to be inclusive of 12 hours test run at site as specified in PS and IS requirements in presence E/M Offr detailed by accepting officer, all testing arrangements/ equipments shall be made available by the contractor for tests. (iv) The quoted rate shall be deemed to be inclusive of first fill of lubricant oil, DHPP for 12 hours testing and final successful acceptance test. (v) Anything missed out above but technically required for efficient working of DG Set is deemed to be included in quoted rates. Item continued as serial no 19.40
E) Control Panel :- Control panel shall be made out of CRCA sheet 14 gauge powder coated dust and vermin proof totally enclosed and consisit the following: (a) Microprocessor based generator set monitering and control system consists of 16 Charactor 2 line LCD disply and to monitor operator interface, fault history, alternator data, Engine data, provision for service adjustement and caliberation of DG control functions, Engine controls,engine protective functions, alternative protective functions etc. (b). Instrument fuses and control wiring. (c). Indication lamps for Set running and load on. (d). Aluminium bus bar copper bus bar TPN for 100 Amps for RYB & 50 Amps for neutral complete for in and out terminalsl wiring with PVC insulated single core copper conductor multistranded wire of 1100 volts grade of suitable capacity including CTs etc, (e). 4 pole MCCBs 63 Amps, 16 KA adjustable type - 01 No
Supply and install testing and commissioning open well submersible pump set with cast iron impeller, directly coupled with motor, minimum total head 28 meter and discharge min 600 LPM (Not less than 7.5HP, 2930 RPM, prime mover) operated on 3 phase, AC, voltage range 200V-440V, 50 Hz. The motor casing shall be ofcast iron, pump shaft/ motor shaft shall be of stainless steel, pump bowls shall be of high graded cast etc. including necessary fixing arrangement in the UG sump of 50000 Ltrs capacity including electrical connections and delivery water connections complete all as specified and as directed. The pump and motor shall comply to all the requirements of relevant IS. (01 No working & 01 Stand by) all as specified and as directed. The make of pumpset shall be of model No KDS 830+ of kirloskar or equivalant approved make in CG/KSB. Note : Motor startor and control cable shall be measured and paid seperately under relevent item of schedule.
Supply, installing, testing and commissioning outdoor type LT Kiosk type, platform mounted, factory made, totally enclosed, dust & vermin proof, IP 55, made of 3.15 mm CRCA sheet, MS flat & angle supports/ frames, duly fabricated and having proper locking arrangement in both front & rear door with 4 side slanting roof duly projected and conforming to IS 5039/ IS 8623 and other relevant IS/IEC codes and CPRI type test approved, duly powder coated both internally and externally suitable for 415 volts, 50 Hz, 3 phase, 4 wire system and comprising of the followings features and accessories / components, all as specified and as directed :- BUSBAR:-(I) Copper busbar suitable for 415 volts 50 Hz AC 3 Phase 4 wire distribution system of capacity 100 Amps for RYB and 50 Amps for N duly insulated including necessary insulators nuts & bolts etc INCOMING:- (a) MCCB 4 pole, 415 Volts, 25 KA , 63 amps - 01 No (b) On load Change over switch panel mounting type 4 Pole, 415 V, 50Hz, 63 Amp - 01 No (c) Indicator Lamp LED type - 01 Set (d) CT of range 63/5 Amps - 01 Set of 3 Nos (e) Multi function meter class 1.0, 5A 3 Phase with LED display flush mounting panel type Model 'A' of L&T WDM 303 FDWAI or equivalent approved make Item continued as serial no 19.70
(f) Control wiring with PVC insulated unsheathed copper conductor ISI marked with control/protection OUTGOING:-(i) MCB TPN, 415 volts, 50 Hz, 10 KA, breaking capacity rating 32 Amps - 02 Nos (For fire pump & 01 Spare) (ii) MCB TPN, 415 volts, 50 Hz, 10 KA, breaking capacity rating 25 Amps - 02 Nos (For Sump Pump) (iii) MCB TPN, 415 volts, 50 Hz, 10 KA, breaking capacity rating 16 Amps - 01 No (For Siren) (iv) MCB SPN, 415 volts, 50 Hz, 10 KA, breaking capacity rating 16 Amps - 01 No (for Street Light) (v) MCB DP, 230 volts, 50 Hz, 10 KA, breaking capacity rating 10 Amps - 01 No (Spare) (vi) Star delta startor fully automatic suitable for 7.5 HP 3 phase AC 3 rating 415 volts 50 Hz AC complete conforms to relevent IS/IEC including necessary power contactors on off push button, over load protection,single phase preventor, under volts protection etc complete with SS enclosure - 2 Nos (vii) Provision for fixing street light control console) Note : Street light timer control box will be measured seperately under ext electric Schedule.
Fire point made out of MS angle and plate for fixing the following on the wall and painted with postal red colour externally and duly lettered with 'FIRE' including the following as per CFEES report:- (a) Fire Extinguisher, Water stored pressure type 9 litres capacity (IS 15683:2006) (b) Fire Extinguishers Dry Chemical Powder (ABC) Type Capacity 4 Kg (IS 15683:2006) Note : Each Job shall comprise of 01 No Fire extinguisher pressure type and 01 No Fire extinguisher ABC type
SUB TOTAL
ROAD & PATH
Lump sum price worked out by the Contractor for “(ROAD & PATH)” as listed in Schedule ‘A’ Part- XII. Representing ** ___ % ______ percent *Above / Below the lump sum price of Rs 3,42,079.30 inserted by the MES in Schedule ‘A’ Part-XII
ROAD & PATH (Misc Items) Sch A Part XII(A)
Preparing WBM surfaces by brushing with wire brushes for removing caked mud etc, sweeping with brooms and finally fanning the cleaned surfaces with gunny bags to remove all loose dirt etc and applying evenly a priming /tack coat with bituminous primer @ 10kg per 10 Sqm using bitumen VG -10 complete all as specified and as directed.
M & L for premix bituminous macadam 50 mm thick (consolidated thickness) with 0.74 cubic meter of stone chippings mixed with 36.50 kg binder per 10 SQM using VG-10 Bitumen, rolled with 8 to 12 tonne power roller complete, all specified and as directed.
M&L for premix bituminous semi-dense asphaltic concrete, 40 mm thick (consolidated thickness with 5.50% binder content by weight of total mix), rolled and compacted to required gradient and camber complete using VG-10 bitumen binder complete, all as specified and as directed. Note : Semi dense ashphaltic bituminous concrete shall be designed as specified and binder content shall be provided as per design mix, contractor shall quote his rates considering the bitumen contents as 5.5% . Any variation in binder content on minus side shall be adjusted at the rate of Rs.40.00 per Kilogram of binder but variation on plus side shall not be paid extra. Contractor shall quote accordingly.
SUB TOTAL
CONSTRUCTION OF TENNIS COURT OF SIZE 30M X 17M
Lump sum price worked out by the Contractor for “(CONSTRUCTION OF TENNIS COURT OF SIZE 30M X 17M)” as listed in Schedule ‘A’ Part- XIII. Representing ** ___ % ______ percent *Above / Below the lump sum price of Rs 6,07,270.53 inserted by the MES in Schedule ‘A’ Part-XIII
PROVN OF PLINTH FOR TRANSFORMER OF SIZE APPROX 2 M X 2 M X 1 M AND FENCING WITH APPROX 30M LENGTH AND HEIGHT APPROX 2MTR AROUND THE TRANSFORMER
Lump sum price worked out by the Contractor for “(PROVN OF PLINTH FOR TRANSFORMER OF SIZE APPROX 2 M X 2 M X 1 M AND FENCING WITH APPROX 30M LENGTH AND HEIGHT APPROX 2MTR AROUND THE TRANSFORMER )” as listed in Schedule ‘A’ Part- XIV. Representing ** ___ % ______ percent *Above / Below the lump sum price of Rs 18,647.73 inserted by the MES in Schedule ‘A’ Part-XIV
DEFECTIVE WORKS
Lump sum price worked out by the Contractor for “(DEFECTIVE WORKS)” as listed in Schedule ‘A’ Part- XV. Representing ** ___ % ______ percent *Above / Below the lump sum price of Rs 4,76,394.04 inserted by the MES in Schedule ‘A’ Part-XV
PROVISIONAL LUMP SUM
(a) Construction of Dias of Size 9m x 7.5m - 0 No. = `. 0.00 (b) Terrace Tank with float valve of capacity 20,000 Ltrs with PCC platform and Shed made up of angle iron of 50x50x6 mm with PP GI sheet at roof of size 6'x6'x4' with PCC platform/base for pump set at terrace for fire fighting system - 1 No = Rs. 2,00,000.00 TOTAL AMOUNT = 2,00,000.00 Add/deduct ______%(_________ percent) Rs_______________ Above/below Total cost is at par market, Bidder to quote total amount after considering percentage addition thereto to cover over head and profit as per condition 5 of IAFW-2249
SCHEDULE OF CREDIT
Lump sum price worked out by the Contractor for “(SCHEDULE OF CREDIT)” as listed in Schedule ‘A’ Part- XVI. Representing ** ___ % ______ percent *Above / At Par the lump sum price of Rs 44,60,815.00 inserted by the MES in Schedule ‘A’ Part-XVI
Note 1:- (Applicable for all parts/items) : The bidders/contractors are advised to read tender document, all drawings & all corrigendum / amendments and general condition of contracts before entry / quoting the rates. Note 2:-The contract sum shall be arrived at after deducting amount of schedule of credit from the total quoted amount.
C. M. AGARWAL AND CO
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .