Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹9.3 LAccepted-Finance | ₹9.3 L | L1 | Accepted-Finance Being L1 accepted |
| 2 | L2₹11.1 L+₹1.7 L (18.5%)Rejected-Finance 58 A TUEM TUEM INDUSTRIAL ESTATE 403512 NORTH GOA GOA 403512 | NORTH GOA | GOA | 403512 | ₹11.1 L+₹1.7 L (18.5%) | L2 | Rejected-Finance Being L2 rejected |
| 3 | Rejected-Technical | - | - | Rejected-Technical MSME Exemption claimed without enclosing the required MSME documents |
Tender Value
₹10.6 L
EMD Value
₹21,193
Closing Date
4 Aug 2026, 3:00 pmClosed
Executive Engineer WD XXII
WD XXII PWD Fatorda
S.I.T.C of 60 KVA DG set at PM Shri Kendriya Vidyalaya No. 1, Vasco Da Gama, Goa under Members of Parliament Local Area Development (MPLAD) Scheme.
2026_PWD_30631_1
3/26-27/PWD/WDXXII/MnE/ ASW/TN-15/01 dtd.27.07.2026
Open Tender
Electrical Works
Percentage
180 days
Vasco Da Gama Goa
Please refer Tender Notice TN-15 dtd 27.07.2026
6 documents required · 6 mandatory
₹5,000
Yes
₹21,193
Yes
11 Aug 2026
27 Jul 2026
6 Aug 2026
28 Jul 2026
4 Aug 2026
28 Jul 2026
This is a percentage-rate BOQ. The schedule below shows estimated quantities and rates. Bidders quote a single percentage above or below the total estimated cost.
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Supply and Installation of 60kVA CPCB4+ GRP DG Set 60kVA (48kWe) Prime, 415V, 50Hz, 1500RPM, 0.8PF, 3PH - as per CPCB4+ Engine :E483 CPCBIV VECV, of make Cummins, VECV EITCHER, Kirloskar, KOEL Greaves, Leyland.
Alternator : LSAP 42.3 K, of make Stamford, Cromptom Greaves, Leroy Somer, Mecc Alte, Koel Greaves SCOPE Includes :- * DG Set
* Canopy (75dBA @ 1mtr)-- GRP CANOPY
* Base frame
* AVM Pads
* AMF Logic Panel
* DEIF SGC120 controller.
* 3p Breaker
* Silencer with bellows
* Inbuilt fuel tank
* Battery with leads
* Oil
* Coolant" The DG set to be mounted on channel iron base frame complete with required foundation for PCC as required with antivibration pads, foundation will include earthwork in excavation rubble packing, cement concrete, centering and shuttering, RCC, cement plaster and TMT steel reinforcement bars complete as per the details/specifications and drawings given by the Engineer in charge | - | No | 0.16 | - |
| 2Supply and providing Chemical earthing system (Pipe in pipe type) with Outer pipe of the electrode having minimum 80mm diameter as per the enclosed specifiations and drawing.The outer and the inner hot dip galvanised MS pipes shall conform to the specifications and the space inbetween shall be filled with highly crystalline conductive and anti- corrosive mixture conforming to IS-3043. The earth electrode shall be CPRI tested.The scope of work includes boring( 300mm diamimnimum)/exvavation of soil/hard rock, refilling with required quantity of back fill compound/Ground resistance enhancement powder of requisite quantity, compaction, constuction of masonary chamber etc complete as required to obtain the desired value.Aluminium tag with embossed earthing value shall be permanently attached to the pipe electrode | |||||
| 2.01 | 2 metres length electrode | - | Set | - | - |
| 3Supply of Back fill Compound/ Groung resistance enhancement powder conforming to the enclosed specifications. | |||||
| 4Providing and fixing 25 mm x 5 mm GI strip on surface or in recess for coneections etc. as required | |||||
| 5Supply and making cable end terminations with compression gland and copper lugs for following sizes of PVC insulated PVC sheathed/XLPE aluminium conductor cable of 1.1 KV grade, complete as required. | |||||
| 5.01 | 2 x 16 Sq. mm. | - | Each | - | - |
| 6Supply of 3 1/2 core armoured PVC/XLPE insulated, PVC sheathed aluminium conductor cable of 1.1 KV grade with ISI mark conforming to IS:1554(Part I) ,IS:7098(Part I) with latest amendments of following size. | |||||
| 6.01 | 3 1/2 Core 25 sq.mm | - | Metre | - | - |
| 7Laying of one number PVC insulated and PVC sheathed/XLPE power cable of 1.1 KV grade of size not exceeding 25 sq.mm direct in ground including excavation in the form of a trench as per Cable Trench Drawing provided by the Engineer-Incharge,sand cushioning with screened sand bed of 20mm thick , protective covering with bricks placed breadth-wise on top of cable all over the run( the brick protection shall cover the cable and project atleast 5 cms over the sides of the cable) and backfilling the excavated earth without stones or hard material and making the surface proper with 15 cm crown on the top complete as required. | |||||
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.90 MB
Tendernotice_2.pdf
PDF • 0.85 MB
Tendernotice_3.pdf
PDF • 0.82 MB
Tendernotice_4.pdf
PDF • 0.21 MB
BOQ_31040.xls
BOQ • 0.27 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .