Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Tender Updates
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹32.1 CrAccepted-AOC CIVIL WORKS FOR CONSTRUCTION OF ADDITIONAL OFFICE BLOCK AT IOCL PUNJAB STATE OFFICE BUILDING PLOT NO 3A SECTOR 19 A CHANDIGARH UT | NA | NA | 160001 | L1 | Accepted-AOC Accepted | |
| 2 | L2₹36.5 Cr+₹50.8 L (1.41%)Rejected-Finance | L2 | Rejected-Finance Rates higher than L1 | |
| 3 | L3₹38.0 Cr+₹2.0 Cr (5.54%)Rejected-Finance PLOT NO F AND G RAKBA DARAKHERA PROFESSOR COLONY NAGARPARISAD THANESAR KURUKSHETRA 136118 | KURUKSHETRA | KURUKSHETRA | HARYANA | 136118 | L3 | Rejected-Finance Rates higher than L1 |
Tender Value
₹43.5 Cr
EMD Value
₹87.1 L
Closing Date
2 May 2024, 12:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Ajay Panghal
Municipal Corporation Panchkula
Construction of office Building of Directorate of Urban Local Bodies, Haryana at IP-2 Sector 5B MDC Panchkula
2024_HRY_368354_1
20246C848794 FF08 499F A1FD 1C157B43D62F281ULB
Open Tender
Civil Works
Works
730 days
Panchkula
2 documents required · 2 mandatory
₹20,000
₹87.1 L
Yes
Panchkula
8 Jan 2025
14 Mar 2024
2 May 2024
14 Mar 2024
2 May 2024
14 Mar 2024
27 Mar 2024
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | HDMI 2.0 matrix switcher with HDCP 2.2 support and capable of handling resolutions up 4K@60Hz 4:4:4 / 8 bit colour with static and dynamic HDR output support for each channel. The matrix features advanced independent EDID management control for each HDMI input as well as an Easy EDID analyser. The analog and digital audio outputs can be set to follow the HDMI video route or can be independently routed either by API or web control interface. Built in re-clocking circuitry ensures the switcher is backwards compatible with sources with older HDMI version chip sets. The matrix switcher can be controlled via front panel buttons, front panel IR, external IR, remote IR, RS232, and Ethernet. The matrix includes a simple IR remote control to allow IR switching. The matrix also features a full command set for RS232 and Ethernet control with third party control systems, plus control via web user interface. | 4,735 | Metre | - | - |
| 2 | MR of 120mins Fire Rated Glazed Sliding door
Supply and installation of tested Vetrotech Saint-Gobain VDSTM fully glazed fire rated double leaf automatic sliding door with 120 minutes of integrity and radiation control (EW 120) and insulation for 30 minutes (EI 30) with symmetrical (Bi-Directional) fire protection. The frames shall be imported cold rolled Forster profiles from Switzerland using DX52D plus Z275-M-A-O steel sheets (As per EN standard EN 10327). The door frames are cold rolled from 1.5 mm steel sheet to form a profile of 50 mm x 50 mm on all sides. The door shutter would have the top rail, side rail and bottom rail dimensions of 50 mm x 50 mm. The overall door opening shall be as per tested evidence and tested as per EN 1634-1 in an accredited international laboratory.The glass should be Contraflam Lite 14mm clear 120 min fire rated for Integrity, Radiation control (EW 120) and partially insulation (EI 30) Non Wired Toughened Interlayered glass with a light transmission of 86% and a sound reduction of 38 dB and manufactured in UL and TUV audited Facility and including UL-EU Certification and compliant to class 1(B)1 category of Impact Resistance as per EN 12600. The glass shall be tested for UV resistance duration of 5000 hours. The glass shall provide bi-directional (Symmetrical) fire protection.The door has to be connected to the surrounding construction by means of interlocking labyrinths lined with intumescent tapes as per the test evidence and connected to the sliding mechanism at the top. The automatic sliding mechanism shall be as mentioned in the tested evidence or Assessment and shall have steel rollers. The sliding mechanism shall have inbuilt battery backup to ensure automatic operation for a minimum of 30 cycles following a power outage. The glass should be held in its place with the help of 1.5 mm cold rolled steel beading and Kerafix 2000 ceramic tape with cross section of 4 x 15 mm as per the test evidence. Beading shall be clipped on using Stainless Steel self-tapping screws fixed at a distance of 70 mm from the edges and 150 mm c/c henceforth. The glass panes are to be supported on non-combustible 6 mm Calcium Silicate setting blocks. The test report should be tested in Thomas Bell-WRIGHT International Consultants and will be considered valid only if it contains the stamp and signature of the authorized signatory from Saint-Gobain Glass India Ltd. T1 | 208 | Each | - | - |
| 3 | MR of 120mins Fire Rated Glazed Single leaf door
Supply and installation of tested Vetrotech Saint-Gobain VDS® fully glazed fire-rated Latched single leaf door system with 120 minutes of integrity and radiation control (EW 120) with symmetrical (bi-directional) fire protection through a VDS Certified Installer. The frames shall be made of imported cold rolled profiles. The door frames are cold rolled from 1.5 mm steel sheet to form a profile of 50 mm x 50 mm on all sides. The door shutter would have the top rail, side rail and bottom rail dimensions of 50 mm x 50 mm. The overall door opening shall be as per tested evidence and tested as per EN 1634-1 in an accredited international laboratory. The glass shall be CONTRAFLAM LITE (14mm) clear, non-wired, toughened, interlayered, 120 minutes fire-rated glass for integrity and radiation control (EW 120) and insulation (I 20) with a light transmission of 86% and a sound reduction of 38 dB and manufactured in UL and TUV audited facility and including UL-EU Certification (File number R38101) and compliant to class 1(B)1 category of Impact Resistance as per EN 12600. The glass shall be tested for 5000 hours of UV resistance as per EN ISO 125 plus A143-4. The glass shall be EPD (Environmental Production Declaration) verified in accordance to EN 15804 and ISO 14025 in which its life cycle assessment is performed considering Cradle to Gate system boundaries. The glass must produce a recycled content declaration committing to a pre-consumer cullet of up to 11% and post- consumer cullet less than 1%. The glass shall provide bi-directional (symmetrical) fire protection. The shutters should be fixed to the frame using weld-on hinges of dimensions 179mm X 20mm. The profiles shall have grooves to incorporate fire-resistant gaskets. The doors shall incorporate drop down seal at the bottom. The glass should be held in its place with the help of 1.5 mm cold rolled steel beading and Kerafix 2000 ceramic tape with cross section of 4 x 15 mm as per the test evidence. The beading shall be clipped on using stainless steel self-tapping screws fixed at a distance of 70 mm from the edges and 150 mm c/c henceforth. The glass panes are to be supported on non-combustible 5 mm thick calcium silicate setting blocks. . The inactive leaf should be fixed to the frame using a tower bolt at meeting edge at top or as per the tested evidence. The doors shall be manufactured in a TUV audited facility. The installation of the door shall be through a VDS certified Installer who is trained and certified by Vetrotech Saint-Gobain. The installer shall have an active VDS Certified Installer certificate from Vetrotech Saint T2 | 4,735 | Metre | - | - |
| 4 | MR of EPS Protection Board
Protection Board in Verticals: Providing and installing of 25 mm with 32 density thick EPS protection board of approved over the layer of Polyurethane using appropriate compatible adhesive to prevent any damage to membrane during backfilling. The protection board is to be spot- bonded on the applied waterproofing. Contractor shall submit methodology statement with all details in illustrative sketch form and get approved from Engineer-in-charge. Application shall be carried out by registered applicator of the manufacture and approved by the Engineer-in-charge. Cost shall include all materials, labour, TandP, wastage etc. as mentioned above in the item. Applied area of PU coating as per approved methodology (horizontal and vertical) shall be measured for payment without any overlaps. MAke: E-pack, Ebaco, East India Technology, Speriplast T5 | 208 | Each | - | - |
| 5 | MR of Ready mix plaster
Providing and Applying 12 mm thick plaster(smooth or wired finished plaster) of polymer added ready mix cement mortar finished with trowel. GI hexagonal chicken mesh of size aperture 20 mm x 20 mm of 22 gauge and minimum 200 mm wide at RCC and masonary junctions or between different material and 145 GSM of minimum 150 mm wide fiber glass mesh with alkali resistant coating shell be fixed at plumbing and electrical works chasing areas, at corner and doors and window joints as per manufacturer`s specifications with GI nalis, hacking of concrete/ application of bonding agent, finishing, curing, scaffolding for all floor, all level, all height etc. complete as directed by Engineer-in-charge . Rate shall be inclusive of bonding agent, chicken mesh, glass fiber mesh, provision of groove / drip mould as per drawing etc. complete and as directed by Enigineer-in charge. Make: Weber, Kerakoll, Mapei T6 | 4,735 | Metre | - | - |
| 6 | MR of Car deck Flooring
Surface preparation by appropriate means like removing spalled concrete with chisel and hammer or grinding
with rotary diamond wheel grinding machine to roughen up the surface and prepare surface for primer
application. Applying 2 coats of clear solvent free epoxy primer Weberfloor
Easygrip 120 over the prepared concrete surface and laying 3 -5 mm thick self leveling screed Weberfloor
Undercoat 1200. Make: Weber,Mapei,chryso T7 | 208 | Each | - | - |
| 7 | MR of Terrace WP
roviding and applying elastomeric, PU coating water proofing and insulation system to be applied at required consumption to achieve a minimum 1.5mm DFT with required coat (minimum 2 coat) uniformly spread in entire area. System shall be executed as follows: 1)Surface preparation shall be done as per manufacturer specifications followed by single component PU water proofing coating 2)Repairing cracks on mother roof slab by cutting and making V grooves in 25x25 mm, and filling with a polymer modified sand-cementitious mortar using Webertec SBR Litx , of 1:3 proportion and filling the groove with CM (1:3) as recommended by manufacturer specification. 3)Making fillet and haunches with polymer modified mortar using Webertec SBR Litx or as per manufacturer of minimum size 50mm x 50mm 4)Supplying and applying a base coat of single component polyurethane based waterproofing coating, having elongation ) 600%, crack bridging= 2 mm, tensile strength of ) 4.0 Mpa, watervapour permability )30 gm /sqm per day, minimum DFT 1.5mm (as per ASTM D 412),shore hardness 65 on a surface prime with 2 component water thinable 2 component epoxy primer at the corners above the mother slab of roof and over the concrete haunches provided in the periphery of the slab at the junctions of the parapet wall or 450mm 5) Spray applying an average 80 mm thick polyurethane foam (CFC and HCFC free), with a core density of 45-50 kg /m3, thermal conductivity of 0.023 W/m.k at 25°C mean temperature (as per ASTM C518/91), tensile strength of ) 300kPa (as per ASTM D 1623), compressive strength with rise of )300kPa (as per ASTM D-1621), closed cell content having apparent vol of ) 90% (as per ASTM D 6226/ 2856) and fire resistance property conforming to Class B2 as per DIN 4102.
6)Application of PU form shall be followed by, supplying and applying a base coat of one component polyurethane based waterproofing coating Weberdry PUR Basic, having elongation of ) 600% and tensile strength of ) 4 MPa, with minimum DFT 1.5mm (as per ASTM D 412), over a PU foam and vertical above upto 450mm. 7)Supplying and laying 300 gsm Geotextile (non woven polyester) over the entire membrane maintaining proper overlaps of 100 mm and above vertical as per manufacturer`s specification. 8)Applying average 100 mm thick M25 grade concrete screed including providing control joints in 3M X 4M grids size, and providing the angular haunch of 50mm X 50mm using M25 grade concrete at the corners of the slab-parapet wall junctions all around the periphery. Screed concrete shall be cut by mechanical means and filling the groove with a one component Polyurethane Sealant that is moisture triggered and cast immediately on saw cutting joints on green concrete. The width of sealant fill shall not exceed 10mm. (Screed as per above description shall be paid separately). Providing and applying UV resistant, a spray/ roller applied solar reflective cum waterproof coating Weberdry PUR Coat for terrace area with elastomeric property and having a SRI value not less than 90 (as per ASTM E 1980), with crack bridging ability up to 1mm (as per ASTM C 836: 1995) and elongation at break of 250 % (as per ASTM D 412 : 2002), having tensile strength= 2.0 Mpa with a coverage of 400 gm/sqm in 2 coats.Make: Weber, Kerakoll, Mapei T3 | 4,735 | Metre | - | - |
| 8 | MR of Retaining wall treatment
Providing and applying single component, elastomeric, pitch modified PU coating water proofing system of Weberdry PU Bitseal to be applied at consumption of 2.5 kg/sqm to achieve a minimum 1.5 mm DFT with required coat (minimum 3 coat) uniformly spread in entire area. System shall be executed as follows: 1)Surface preparation shall be done as per manufacturer specifications followed by single component PU water proofing coating 2)making fillet/ provision of corner tape
3)PU self priming application as per manufacturer recommendation 4)Pitch PU waterproofing can be applied by roller, spray or short hair brush PU waterproofing. Waterproofing shall be taken covering entire parapet wall up to min 300mm. 5)Laying Geotextile (non-woven polyester) membrane in 300 micron thickness as recommended by water proofing system provider, with a min of 100mm wide overlap and on typical locations like wall and floor junctions, rain water down take etc. shall be embedded between two coats as per manufacturer`s specifications. 6)Protectionscreedlaidtoslopewhichshallbepaidinrelevanttenderitem. The pitch modified PU coating system must deliver the following properties: 1)Tensile Strength - )1.0 N/mm2
2)Crack bridging capacity - ) 3 mm as per EN1062-7(A) 3)An elongation of minimum 500% as per ASTM D 412 with puncher resitant as per ASTM E 154 ) 30 N Cost includes all material, labour, TandP, wastage involved as mentioned in the item except protection concrete screed. Contractor shall submit methodology statement with all detail in illustrative sketch form and get approved from Engineer-in-charge. Application shall be carried out by approved applicator of manufacture and as per recommended by manufacturer. Plan area (in to in of parapet wall) of balcony/ sunken/ terrace etc shall be measured for payment. Make: weber, Mapaei, Kerakoll T4 | 208 | Each | - | - |
| 9 | MR of Car deck Flooring
Priming epoxy screed with epoxy primer Weberprim Easygrip 120. After 12 - 16 hours applying 1 coat of single component polyurethane base coat Weberfloor Cardeck BC with elongation upto 100% and allowing it to dry for 16-24 hours. Topping the flexible membrane with single component wear and tear resistant polyurethane top coat Weberfloor Cardeck Finish in desired RAL shade. Make: Weber,Mapei,chryso T8 | 4,735 | Metre | - | - |
| 10 | MR of Ramp area
Priming epoxy screed with epoxy primer Weberprim Easygrip 120. After 12 - 16 hours applying 1 coat of single component polyurethane base coat Weberfloor Cardeck BC with elongation upto 200% and tensile strength upto 4 MPa. Broadcasting quartz sand of 0.3 -0.6 mm thickness evenly on wet membrane so as to obliterate the base coat. After 16-24 hours of drying remove excess of sand thoroughly with broom and topping the textured surface with single component wear and tear resistant polyurethane top coat Weberfloor Cardeck Finish in desired RAL shade. Make: Weber,Mapei,chryso T9 | 208 | Each | - | - |
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
BOQ_444086.xls
BOQ • 0.59 MB
141943764.pdf
Tender Documents • 0.47 MB
141943765.pdf
Tender Documents • 1.57 MB
141943767.html
Tender Documents • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .