Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹13.3 LAccepted-AOC AZARA GUWAHATI DIST KAMRUP M ASSAM 781 017 | KAMRUP METRO | ASSAM | 781017 | L1 | Accepted-AOC Lowest bidder | |
| 2 | L2₹14.9 L+₹1.1 L (8.13%)Rejected-Finance PO AZARA KAMRUP METRO GUWAHATI 781017 ASSAM | KAMRUP METRO | ASSAM | 781017 | L2 | Rejected-Finance Lowest bid |
Tender Value
Refer Docs
EMD Value
₹30,000
Closing Date
9 Jan 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE (AF) Borjhar
Garrison Engineer (AF) Borjhar, Military Engineer Services, Guwahati Airport- PO, Borjhar Airport, Guwahati-15, Assam, Pin- 781015 Tele 0361 - 2840127
Repair/ Maintenance of External Water Distribution and Allied works at Mountain Shadow, Site C 3 AFSR and MES Area at AF Station Borjhar
2020_MES_381943_3
8782/BOR/E8
Open Tender
Civil Works
Item Rate
270 days
GE (AF) Borjhar
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
Yes
GE (AF) Borjhar
₹30,000
Yes
23 Jan 2021
18 Dec 2020
11 Jan 2021
18 Dec 2020
9 Jan 2021
28 Dec 2020
60 days
Amount
Excavation in trenches not exceeding 1.5 meter wide and not exceeding 1.5 meter in depth and getting out in loose/soft soil for removing/laying of pipe line, complete, all as specified and directed.
Returning, filling in including spreading, leveling and well ramming in layers not exceeding 25 cm in soft/loose soil, complete, all as specified and directed.
Removing excavated soil/materials, not exceeding 50 meter and depositing where directed at a level not exceeding 1.5 meter above the starting point, complete, all as specified and directed.
Taking up unserviceable GI water main (including all fittings) complete all as directed and specified for the following bore of pipes:-
(a) 20 mm bore
(b) 25 mm bore
(c) 40 mm bore
(d) 50 mm bore
(e) 80 mm bore
(f) 100 mm bore
Supply & Laying Galvanized iron tubing, medium grade with all fittings and laid in trenches complete all as specified and directed for the following sizes:-
(a) 20 mm bore
(b) 25 mm bore
(c) 40 mm bore
(d) 50 mm bore
(e) 80 mm bore
(f) 100 mm bore
Relaying galvanized iron tubing with all fittings after cleaning internal surface of serviceable pipes by using of wire brushed and cleaning throughly with fresh water and taking out mud/soft deposited inside the pipes in any length laid in trenches complete all as specified and directed for the following sizes: Note: Old GI pipe retrieved under item No. 4.00 above shall be used for relaying.
(a) 20 mm bore
(b) 25 mm bore
(c) 40 mm bore
(d) 50 mm bore
(d) 80 mm bore
(e) 100 mm bore
Taking up CI water mains (including all fittings)with spogot and socket ends and lead joints including burning out joints and removing leads, complete, all as directed and specified for the following bore of pipes:-
(a) 100 mm bore pipe
(b) 150 mm bore pipe
Supply & Laying CI pipes with spogot and sockets centrifugally cast class LA in any length laid in trenches complete all as specified and directed for the following sizes:
(a) 100 mm bore pipe
(b) 150 mm bore pipe
Relaying CI pipes with spogot and sockets ends after cleaning internal surface of serviceable pipes by using of wire brushed and cleaning throughly with fresh water and taking out mud/soft deposited inside the pipes in any length laid in trenches complete all as specified and directed for the following sizes:
(a) 100 mm bore pipe
(b) 150 mm bore pipe
S&F Cast iron sluice valve of size 150 mm bore heavy duty (PN-1) with flanged ends, brass spindle any pattern with iron wheel head conforming to IS including jointing and jointing materials, nuts, bolts,rubber gasket and washers and taking down old sluice valve etc complete all as specified
All as per item No 10.00 abov but of size 100 mm bore.
Taking out sluice valves refacing, regrinding and refixing of size 80 mm dia
Taking out sluice valves refacing, regrinding and refixing of size 100 mm dia
Taking out sluice valves refacing, regrinding and refixing of size 150 mm dia
Taking out reflux(NRV) valves refacing, regrinding and refixing of size 100 mm dia
S&F Valve, reflux (NRV) with by-pass arrangement , complete of size 100 mm (4") dia.
Dismantling and taking out unserviceable Cast iron fittings up to 150 mm bore pipe including burning out lead joint, complete, all as directed.
M&L for Cast iron fittings for spigot and socketed pipes such as bends, tail piece, tee,collars, etc up to 150 mm bore medium duty and fixed in position complete all as directed.
Burning out lead joints in position including removing of old lead from the work site leeping aside for ruse or remove to store all as directed for following CI pipes :-
(a) 80 mm dia bore
(b) 100 mm bore pipe
(c) 150 mm bore pipe
Run lead joints except lead and pipe for pie and pipe spun yarn complete all as specified and directed for the following sizes (lead obtained from item No 7 & 19 will be used) :-
(a) 80 mm dia bore
(b) 100 mm bore pipe
(c) 150 mm bore pipe
M&L for Run lead joint complete with all jointing materials for the following sizes:-
(a) 80 mm bore
(b) 100 mm bore
(c) 150 mm bore
Dismantling and taking out unserviceable stop valves of following size:-
(a) 50 mm dia bore
(b) 40 mm dia bore
(c) 25 mm dia bore
(d) 20 mm dia bore
S & F cast copper alloy stope valve with iron wheel head screwed both ends for iron pipe of the following :-
(a) 50 mm dia bore
(b) 40 mm dia bore
(c) 25 mm dia bore
(d) 20 mm dia bore
Supply only Pig wool complete all as specified and directed.
M & L for Cutting cast iron pipes and reducing to required length before laying of following size :--
(a) 150 mm bore
(b) 100 mm bore
(c) 80 mm bore
Drilling and tapping cast iron water mains (in position) for branch connections of the internal dia 20 mm bore complete all as soecified and directed.
M & L for 3-layer PP-R Polypropylene random (co polymer) pipes SDR 7.4 & SDR 11 UV stablised and antimicrobial fusion welded having thermal stability for hot & cold water supply all PP-R plain & brass threaded polypropylene random fittings laid in trenches of size 20 mm dia
All as per item no 27.00 here in before but of size 25 mm dia
All as per item no 27.00 here in before but of size 40 mm dia
All as per item no 27.00 here in before but of size 50 mm dia
All as per item no 27.00 here in before but of size 63 mm dia
All as per item no 27.00 here in before but of size 90 mm dia
All as per item no 27.00 here in before but of size 110 mm dia
M & L for Making connection of PP-R distribution branch with PP-R main of following sizes by providing and fixing tee including cutting and making fusion joint etc of size 16 to 40 mm bore dia complete all as specified and directed.
All as per item no 34.00 herein above but of size 50 to 75 mm bore dia
Supply and fixing 3 mm thick MS sheet cover plate with locking arrangementsin existing valve pit and removing of old / rusted MS cover all as directed.
S&F PPR Gate valve of size 20 mm bore, complete, all as directed.
S&F PPR Gate valve of size 25 mm bore, complete, all as directed.
S&F PPR Gate valve of size 40 mm bore, complete, all as directed.
M&L for Construction of brick masonry valve pit of internal dimension 90 cm x 90 cm x 90 cm depth with sub class 'B' bricks in CM (1:4) and 10 mm thick plastering in CM (1:4), PCC (1:4:8) type D2 (Using 40 mm graded broken stone aggregate) as in foundation lean concrete, PCC (1:3:6) type CI (using 20 mm graded broken stone aggregate) as in bedding and copping MS frame with 40 x 40 x 6 mm angle iron 3 mm thick MS sheet cover plate with locking arrangements, hinges and two coats of synthetic enamel paint over one coat of red oxide primer including preparation of surface, three coats of white wash on plastered surface (exposed to view) including necessary excavation in soft loose, soil, returning filling in and removal of surplus soil to a distance not exceeding 50 m complete all as specified and directed.
All as per item No 40.00 here-in-before but valve pit of size 60 x 60 x 60 cm.
Supply only Alum ferric Grade -4 Best quality as per sample with additional requirement for purification of water containing lead (as Pb) 30 PPM Max and arsenic (As 203) 6PPM Max confirming revised 15299:2012 complete all as specified and directed.
Labour only for attending major water supply breakdown complaints including pipe line breakdown,Sluice valve/Gate valve, Necessary road cutting, excavation & also removing of unwanted vegetation grown in service tank complete all as specified and directed.
Baruah Fabrication
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .