Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹70.0 LAccepted-Finance | ₹70.0 L | L1 | Accepted-Finance Being L1 |
| 2 | L2₹71.8 L+₹1.8 L (2.61%)Rejected-Finance MAHALSA ROAD BINAGA KARWAR 581307 | KARWAR | UTTARA KANNADA | KARNATAKA | 581307 | ₹71.8 L+₹1.8 L (2.61%) | L2 | Rejected-Finance Not being L1 |
| 3 | L3₹73.5 L+₹3.5 L (4.96%)Rejected-Finance | ₹73.5 L+₹3.5 L (4.96%) | L3 | Rejected-Finance Not being L1 |
| 4 | L4₹74.2 L+₹4.2 L (5.98%)Rejected-Finance LEKSHMI NIVAS TELANG ROAD NANDANGADDA KARWAR 581 304 | KARWAR | UTTARA KANNADA | KARNATAKA | 581304 | ₹74.2 L+₹4.2 L (5.98%) | L4 | Rejected-Finance Not being L1 |
| 5 | L5₹74.5 L+₹4.5 L (6.39%)Rejected-Finance | ₹74.5 L+₹4.5 L (6.39%) | L5 | Rejected-Finance Not being L1 |
| Sl No | Description | Qty | Unit | K.G.SHANKER L5 | LEKSHMI ENGINEERS L4 | M/S KAMALKANTH NAIK L2 | KVL CONSTRUCTION L1 | KOTIAN -ECC L6 | RAJESWARI CONSTRUCTIONS L3 |
|---|---|---|---|---|---|---|---|---|---|
| 1.00 | M&L for attending to petty repair job to plumbing internal water supply, such as repair to leaking bib tap, pillar tap, mixer, stop cock, angle valves, float valves, concealed stop cock, etc., by tightening and providing washer, disc, spindle, or any other minor accessories; repair to float valve; flushing cistern by minor adjustment; leaking water supply lines by tightening the GI fittings/PVC fittings; or refixing water supply or sanitary fixtures using thread/Teflon tapes, with and including small GI fittings such as GI/PVC elbow, socket, union, as required at site to make the system functional, complete as specified and directed by the Engineer-in-Charge. | 2,000 | Each job | 60 ₹1,20,000 Lowest | 85 ₹1,70,000 | 75 ₹1,50,000 | 150 ₹3,00,000 | 140 ₹2,80,000 | 175 ₹3,50,000 |
| 1.01Note for item no 1: (1) Each repair job shall be measured as one job. (2) Jobs involving replacement of taps/valves shall not be measured under this item. (3) Spindle repaired/replaced shall be measured under a separate item. | |||||||||
| 2.00 | Demolition of cement concrete of any description in sunken floor or in any position complete all as specified and directed. . | 12 | Cum | 1,200 ₹14,400 | 820 ₹9,840 | 1,500 ₹18,000 | 700 ₹8,400 Lowest | 1,600 ₹19,200 | 898 ₹10,776 |
| 3.00 | Treatment of sunken floor slab comprises of the following specifications and all as specified :- | 55 | Sqm | 1,200 ₹66,000 | 1,580 ₹86,900 | 1,000 ₹55,000 | 850 ₹46,750 Lowest | 1,400 ₹77,000 | 985 ₹54,175 |
| 3.01Note for item no 3: (1) M&L for cleaning the sunken/lowered portion of RCC slab surface (including vertical total depth plus skirting height) of floors by wire brush, chisel out any mortar sticking to the surface and brooming completely. 40mm thick average PCC 1:2:4 type B0 using 12.5mm graded aggregate as in padding concrete to achieve proper slope (2) Rendering of uneven surfaces with 5mm thick CM 1:3 mixed with integral water proofing compound @ 2% by wt. of cement consumed. Fill it with water and check dampness and seepage. Where dampness/seepage is noticed, nozzles shall be fixed and grouting to be carried out (WPC shall be measured and paid separately) (3) All junctions points of side wall where CI/GI pipes are passing through shall be sealed with epoxy putty. (4) After drying putty, wash the slab and sides of sunken portion with water and make it clear and clean. (5) M&L for applying two coats of polymer modified cementious water proof coating as per manufacturers instruction to bottom and vertical sides up to finished floor level +100mm height. The thickness of two layer shall be 1mm. When the second layer is still sticky,, coarse sand spray shall be carried for the vertical and bottom surface of the sunken portion all as specified and directed. (This item shall be measured and paid separately). (6) Plaster the bottom and sides up to bottom of the skirting with minimum 20mm thick CM 1:4 mixed with integral water proofing compound @2% wt of cement consumed as per manufacturer's specification including rounding of corners and junctions sloping towards spout. (WPC shall be measured & paid separately). (7) All pipes laid in sunken portion shall be covered with 50mm thick PCC 1:3:6 all round after painting with anticorrosive paint (Black paint shall be paid separately) Note :- Test the water proofed area (ponding test) by filling water for at least 72 hours and tested for leakage seepage and to the entire satisfaction of GE. Test shall be done in presence of reps of PMG and record for each sunken slab shall be maintained. The treatment shall be carried out by authorised applicators of chemicals. Cost of testing is included in the rates quoted above. | |||||||||
| 4.00 | M&L for applying two coats of polymer-modified cementitious waterproof coating, as per the manufacturer's instructions, to the bottom and vertical sides up to finished floor level +100 mm height. The thickness of the two layers shall be 1 mm. When the second layer is still sticky, coarse sand spray shall be carried out for the vertical and bottom surfaces of the sunken portion, all as specified and directed by the Engineer-in-Charge. | 60 | Sqm | 375 ₹22,500 | 325 ₹19,500 Lowest | 500 ₹30,000 | 700 ₹42,000 | 600 ₹36,000 | 665 ₹39,900 |
| 5.00 | Supply only integral water proofing compound complete all as specified and directed. | 45 | KG | 75 ₹3,375 | 58 ₹2,610 | 30 ₹1,350 Lowest | 50 ₹2,250 | 53 ₹2,385 | 40 ₹1,800 |
| 6.00 | M&L for PCC in 1:5:10 type E2 (using 40 mm graded aggregate) as in sunken floor of toilet complete all as specified and as directed. | 16 | Cum | 5,500 ₹88,000 | 4,500 ₹72,000 | 4,000 ₹64,000 | 5,000 ₹80,000 | 6,000 ₹96,000 | 3,450 ₹55,200 Lowest |
| 7.00 | Dismantling/taking out existing hessian base felt or any other existing water proofing treatment from roof including cement plaster and exposing the top surface of RCC slab including removing the dismantled debris to a distance exc 200m & n.exc 250m all as specified and directed | 1,200 | Sqm | 30 ₹36,000 | 40 ₹48,000 | 40 ₹48,000 | 25 ₹30,000 Lowest | 36 ₹43,200 | 35 ₹42,000 |
| 8.00 | Surface Preparation:
Preparing the concrete surface to remove dust, dirt, laitance's etc using mechanical means and treating minor defects in concrete with polymer modified mortar using - SmartCare repair polymer (SBR) | 1,200 | Sqm | 150 ₹1,80,000 | 115 ₹1,38,000 | 50 ₹60,000 Lowest | 100 ₹1,20,000 | 160 ₹1,92,000 | 120 ₹1,44,000 |
Tender Value
₹79.9 L
EMD Value
₹1.4 L
Closing Date
6 Aug 2026, 6:00 pmClosed
GE (SB) KARWAR
GARRISON ENGINEER (SEABIRD) KARWAR Naval Base, Sankrubagh (PO) Karwar - 581308
COMPREHENSIVE B/R REPAIR WITH WATER PROOFING TREATMENT TO TOILET, REPAIRS TO ROOF, CEILING, DAY TO DAY MAINTENANCE AND OTHER CONNECTED WORKS SITE A1 OF NAVAL BASE AREA KARWAR
2026_MES_776005_1
8521/E8
Open Tender
Civil Works
Item Rate
270 days
GE (SB) KARWAR
AS PER NIT
8 documents required · 8 mandatory
₹500
Yes
GE (SB) KARWAR
₹1.4 L
Yes
11 Aug 2026
2 Jul 2026
8 Aug 2026
2 Jul 2026
6 Aug 2026
23 Jul 2026
2 Jul 2026 - 9 Jul 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | M&L for attending to petty repair job to plumbing internal water supply, such as repair to leaking bib tap, pillar tap, mixer, stop cock, angle valves, float valves, concealed stop cock, etc., by tightening and providing washer, disc, spindle, or any other minor accessories; repair to float valve; flushing cistern by minor adjustment; leaking water supply lines by tightening the GI fittings/PVC fittings; or refixing water supply or sanitary fixtures using thread/Teflon tapes, with and including small GI fittings such as GI/PVC elbow, socket, union, as required at site to make the system functional, complete as specified and directed by the Engineer-in-Charge. | - | Each job | 1.25 | - |
| 2 | Demolition of cement concrete of any description in sunken floor or in any position complete all as specified and directed. . | - | Cum | - | - |
| 3 | Treatment of sunken floor slab comprises of the following specifications and all as specified :- | - | Sqm | 1 | - |
| 4 | M&L for applying two coats of polymer-modified cementitious waterproof coating, as per the manufacturer's instructions, to the bottom and vertical sides up to finished floor level +100 mm height. The thickness of the two layers shall be 1 mm. When the second layer is still sticky, coarse sand spray shall be carried out for the vertical and bottom surfaces of the sunken portion, all as specified and directed by the Engineer-in-Charge. | - | Sqm | 11 | - |
| 5 | Supply only integral water proofing compound complete all as specified and directed. | - | KG | 10 | - |
| 6 | M&L for PCC in 1:5:10 type E2 (using 40 mm graded aggregate) as in sunken floor of toilet complete all as specified and as directed. | - | Cum | 11 | - |
| 7 | Dismantling/taking out existing hessian base felt or any other existing water proofing treatment from roof including cement plaster and exposing the top surface of RCC slab including removing the dismantled debris to a distance exc 200m & n.exc 250m all as specified and directed | - | Sqm | 12 | - |
| 8 | Surface Preparation:
Preparing the concrete surface to remove dust, dirt, laitance's etc using mechanical means and treating minor defects in concrete with polymer modified mortar using - SmartCare repair polymer (SBR) | - | Sqm | 13 | - |
| 9 | Providing and installing SmartCare TPO reinforced membrane, a high-performance, heat-weldable, scrim-reinforced thermoplastic polyolefin (TPO) sheet, manufactured and supplied in a thickness of 1.5 mm as per UNI EN 1849-2, designed for waterproofing and heat-shielding roofs of new and existing buildings.
The membrane shall have elongation at break >15% as per UNI EN 12311-2; hydrostatic pressure resistance (6 hours @ 5 bar) as per UNI EN 1928, Method B; tearing strength (N) >300 as per UNI EN 12310-2; puncture resistance (mm) >700 as per DIN 16726-5.12; and tensile strength (N/5 cm) >1100 as per UNI EN 12311-2.
The joints of the membrane shall be welded using a double-seam welding machine, and detailing of the membrane shall be carried out using hand-applied welding tools. The membrane shall be terminated at a minimum height of 300 mm above FFL in vertical areas, using a termination bar, mechanical fasteners, and PU sealant, complete as per manufacturer’s specifications and product data sheets. | - | Sqm | 14 | - |
| 10 | Dismantling of wall and ceiling boards (fibre, pulp, insulation), or insulation boards/ slabs/ blankets of any description and thickness, including frame/ grid of any description, complete all as specified and directed. | - | Sqm | 15 | - |
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.43 MB
BOQ_868969.xls
BOQ • 0.61 MB
Tender8521.pdf
Tender Documents • 1.35 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .