Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹31.1 LAccepted-AOC 259 4TH CROSS HAL III STAGE BANGALORE 560075 | BANGALORE | BENGALURU URBAN | KARNATAKA | 560075 | L1 | Accepted-AOC BEING LOWEST | |
| 2 | L2₹34.8 L+₹3.3 L (10.6%)Rejected-Finance SR NO 281 3 7 ANAND NAGAR NEAR DHANORI JAKAT NAKA LOHEGAON PUNE 411047 | PUNE | PUNE | MAHARASHTRA | 411047 | L2 | Rejected-Finance NOT BEING LOWEST | |
| 3 | L3₹37.0 L+₹5.5 L (17.4%)Rejected-Finance NO 306 SCION AVENUE 4TH A CROSS KAGGADASPURA NEAR GANAPATHI TEMPLE BANGALORE 560093 | BANGALORE | BENGALURU URBAN | KARNATAKA | 560093 | L3 | Rejected-Finance NOT BEING LOWEST |
| Sl No | Description | Qty | Unit | ABHISHEK CONSTRUCTIONS L1 | SCION ENTERPRISES L3 | VP DEVELOPERS AND CONTRACTOR L2 |
|---|---|---|---|---|---|---|
| 1.00 | Demolition of brick / stone / PCC block work built in cement mortar including all quoins, arches, pillars etc., but excluding Ashlar facing, dressed stone work and precast concrete articles complete all as specified and as directed. | 6.5 | CUBIC METRE | 200 ₹1,300 Lowest | 500 ₹3,250 | 300 ₹1,950 |
| 2.00 | Material and labour for Pre-cast cement concrete block masonry with solid blocks, type B1, (1:2:4) using 20mm graded stone aggregates, exc. 10 cm in width and setting in cement mortar (1:4), complete all as specified and as directed. | 6.5 | CUBIC METRE | 6,500 ₹42,250 Lowest | 7,500 ₹48,750 | 7,000 ₹45,500 |
| 3.00 | Supply and fix in repairs PVC (SWR) pipes single socketed 110 mm bore, type 'B' laid with rubber ring joints, fixed to walls complete all as specified and as directed. | 65 | RUNNING METRE | 400 ₹26,000 | 475 ₹30,875 | 350 ₹22,750 Lowest |
| 4.00 | Supply and fix PVC (SWR) 110 mm bore bends of any radius, type 'B' complete all as specified and as directed. | 10 | EACH | 380 ₹3,800 | 450 ₹4,500 | 250 ₹2,500 Lowest |
| 5.00 | Supply and fix in repairs PVC (SWR) pipes single socketed 150 mm bore, type 'B' laid with rubber ring joints, fixed to walls complete all as specified and as directed. | 75 | RUNNING METRE | 500 ₹37,500 Lowest | 550 ₹41,250 | 600 ₹45,000 |
| 6.00 | Supply and fix PVC (SWR) 150 mm bore bends of any radius, type 'B' complete all as specified and as directed. | 10 | EACH | 450 ₹4,500 Lowest | 525 ₹5,250 | 450 ₹4,500 Lowest |
| 7.00 | Dismantling structural steel work of any description not otherwise provided for complete all as specified and as directed. | 3.65 | QUINTAL | 450 ₹1,642.5 Lowest | 450 ₹1,642.5 Lowest | 800 ₹2,920 |
| 8.00 | Material and labour rolled mild steel for roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (beam, tee, angle, channel or flat sections) including distance pieces, cleats etc Fe 410 -W (Gde E- 250) quality A complete all as specified and as directed. | 350 | KILO GRAM | 140 ₹49,000 | 135 ₹47,250 | 120 ₹42,000 Lowest |
| 9.00 | Material and labour rolled mild steel for bands, straps, supports or stays for rainwater, ventilating pipes, including bolts, if required:hooks (stay), heavy, for large gates hook and pintle hinges large hasps and staples chains hand made sliding bolts clamps hold fasts wall ties hooks for hanging fans plain angle cleats for securing purlins to wood trusses or rafters knee piece inserts two way and three way straps, plate washers and similar small articles conforming to Fe-290 Gde-E-165 all as specified and directed. | 15 | KILO GRAM | 140 ₹2,100 | 145 ₹2,175 | 130 ₹1,950 Lowest |
| 10.00 | Fixing only including re adjusting the disturbed 110 mm PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to walls complete all as specified and as directed. | 120 | RUNNING METRE | 100 ₹12,000 Lowest | 200 ₹24,000 | 100 ₹12,000 Lowest |
Tender Value
₹42 L
EMD Value
₹84,000
Closing Date
17 Sept 2025, 6:00 pmClosed
LT COL CHANDRAKANT JOSHI
DRDO Complex, CV Raman Nagar PO, Bangalore 560 093
REPAIRS TO ROOF TREATMENT CHAJJAS PARAPET WALLS GALVALUME SHEETS COLLAPSIBLE GATES AND PLASTERING AT ADE AND DEBEL LAB UNDER GE I R AND D EAST BANGALORE
2025_MES_725452_1
8643/E8
Open Tender
Civil Works
Item Rate
270 days
GE I R AND D EAST BANGALORE
CLASS D CATEGORY a(i)
8 documents required · 8 mandatory
₹500
Yes
GE I R AND D EAST BANGALORE
₹84,000
Yes
9 Oct 2025
22 Aug 2025
24 Sept 2025
22 Aug 2025
17 Sept 2025
5 Sept 2025
22 Aug 2025 - 4 Sept 2025
Amount
Demolition of brick / stone / PCC block work built in cement mortar including all quoins, arches, pillars etc., but excluding Ashlar facing, dressed stone work and precast concrete articles complete all as specified and as directed.
Material and labour for Pre-cast cement concrete block masonry with solid blocks, type B1, (1:2:4) using 20mm graded stone aggregates, exc. 10 cm in width and setting in cement mortar (1:4), complete all as specified and as directed.
Supply and fix in repairs PVC (SWR) pipes single socketed 110 mm bore, type 'B' laid with rubber ring joints, fixed to walls complete all as specified and as directed.
Supply and fix PVC (SWR) 110 mm bore bends of any radius, type 'B' complete all as specified and as directed.
Supply and fix in repairs PVC (SWR) pipes single socketed 150 mm bore, type 'B' laid with rubber ring joints, fixed to walls complete all as specified and as directed.
Supply and fix PVC (SWR) 150 mm bore bends of any radius, type 'B' complete all as specified and as directed.
Dismantling structural steel work of any description not otherwise provided for complete all as specified and as directed.
Material and labour rolled mild steel for roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (beam, tee, angle, channel or flat sections) including distance pieces, cleats etc Fe 410 -W (Gde E- 250) quality A complete all as specified and as directed.
Material and labour rolled mild steel for bands, straps, supports or stays for rainwater, ventilating pipes, including bolts, if required:hooks (stay), heavy, for large gates hook and pintle hinges large hasps and staples chains hand made sliding bolts clamps hold fasts wall ties hooks for hanging fans plain angle cleats for securing purlins to wood trusses or rafters knee piece inserts two way and three way straps, plate washers and similar small articles conforming to Fe-290 Gde-E-165 all as specified and directed.
Fixing only including re adjusting the disturbed 110 mm PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to walls complete all as specified and as directed.
Demolition of cement concrete in ground floors and pavings not exc 15 cm thickness (below or above ground level) and disposing of debries outside MD land complete all as specified and as directed.
Material and labour for 40 mm thick plain cement concrete (1:2:4), type B-1, using 20 mm graded stone aggregate as in floors finishing surface even and fair and all as specified and as directed.
Material and labour for cutting V grooves 15mm x 15mm in existing roof or terrace and cleaning out and filling /making good with epoxy based compound NITOMORTAR PE of FOSROC chemicals or Equivalent as per directions of manufacturer complete all as specified and as directed
Providing, Supplying, and applying of four components Inorganic-Organic IPN based self-smoothing 2mm thick trowel applied flooring system like InOrthane of Dr CIPY or equivalent make, having compressive strength between 38-40 MPa as per ASTM D 579; tensile strength not more than 10 MPa as per ASTM D 638; elongation not less than 3% as per ASTM D 638; Abrasion resistance should not be more than 16mg loss by CS 17 wheel 1000 cycles, according to ASTM D 4060, Flexural strength should not be less than 20 MPa as per ASTM D 790; Shore D hardness minimum 75 as per ASTM D 2240; Impact resistance between 9-10 N-m as per ASTM D 2794, Scratch resistance value should be 8 Mohs Scale as per ISO 13630, all the above process shall be undertaken by a manufacturer approved applicator, the surface must be clean, dry, and sound concrete and shall be surface prepared using scarification & Grinding.
Priming : Providing, Mixing and applying 1 coat of Efflorescence resistant penetrating primer, Dr. Fixit Primer seal primer at a rate of 7.0 to 8.0 sq.mt / Litre in the SSD condition and allow the primer to dry for 4 hrs prior to application of Dr. Fixit Roof seal Ultra topcoat waterproof coating systems all as specified and as directed.
Supply and fix in repairs venetian blinds, horizontal type, 20-30mm slot width of approved fabric and top rails linked together by a cord pulley system including dismantling old damaged one complete all as specified and as directed. NOTE :- The colour,design and shade shall be as approved by GE.
Demolition of cement Concrete of any description and in any position not otherwise specifically provided for removal of debries complete all as specified and as directed.
Material and labour for repair to cracks by cut opening the cracks in V-groove manner up to 5 to10 mm wide by mechanical cutter, clean the groove with air blower to remove dust, dirt etc., fill the cracks with Dr. Fixit PU Sealant after necessary cleaning. post filling, apply one coat of polyurethane coating over the sealant by sandwiching 45 gsm fiber mesh between sealant and PU coating. The width of PU coating shall be 100 mm, applied all along the length of cracks complete all as specified and as directed.
Material and labour for Plain Cement Concrete, (1:2:4), type B0, using 12.5mm graded stone aggregate as in roof in roof kerbs or mud stops, rounded or chamfered on edges and levelling etc complete all as specified and as directed.
Material and labour for rendering 10mm thick cement screed over roof concrete surface in CM (1:3) and finishing the surfaces even and smooth without using extra cement with water proofing compound complete all as specified and as directed. NOTE :- WPC shall be measured and paid separately.
Supply only integral water proofing compound complete all as specified and as directed.
Providing and applying single component, GRIHA certified, water based eco-friendly high performance UV resistant elastomeric hybrid polyurethane coating, Dr. Fixit Roof seal Ultra without dilution spreading at the rate of 0.70/litre/Sq.mt/Coat in 1st coat until all surface is covered, laying a 45 GSM Fibre glass mesh as a reinforcing material which is incorporated in the coating when the first coat is still in wet condition. Allow the first coat to dry for approximately 4-6 hours before applying the 2nd coat at 90° to the first coat. Ensure there are no pinholes or air bubbles on the membrane surface. Apply second coat of Dr. Fixit Roof seal Ultra without dilution, spreading at the rate of 0.70 litre / Sq.mt /Coat to achieve total dry film thickness of 850 to 1000 microns at forced coverage at the rate of 1.40 litre / Sq.mt in 2 coats.
The coating shall be done on entire horizontal area , upstands, vertical parapet wall etc., this coating shall meet and exceed the ASTM D 6083 - 97a standard specification. attains a Tensile strength of ≥ 4.00 N/mm2 with 45 GSM glass fibre mesh confirming to ASTM D 412; Elongation at break ≥300% and crack bridging ability up to 3 mm, Solar Reflectance Index as per ASTM E 1980 – 105, Water permeability @5 bar – Nil as per EN12390 - 8:2019. Air cures the coating for 7 days. Priming : Providing, Mixing and applying 1 coat of Efflorescence resistant penetrating primer, Dr. Fixit Primerseal primer at a rate of 7.0 to 8.0 sq.mt / liter in the SSD condition. Allow the primer to dry for 4 hrs. Prior to application of Dr. Fixit Roofseal Ultra topcoat waterproof coating systems complete all as specified and as directed.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing rubbish off the premises complete all as specified and as directed.
Material and labour double charged vitrified ceramic tiles of size 9-10 mm thick dark shade, area of each tile not exceeding 0.36 sqm, as in floors etc., set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including 15mm thick screed bed in cement mortar (1:6) complete all as specified and as directed.
Material and labour for Plain Cement Concrete, (1:2:4), type B-1, 30 mm thick using 20 mm graded stone aggregate as in flooring finished fair and even complete all as specified and as directed.
All as per Sl Item No. 23.00 above but as in skirting over and including 10 mm thick backing coat in CM (1:4) complete all as specified and as directed.
Dismantling plain or corrugated steel sheeting, any gauge, thickness, including Nainital or similar pattern roof covering, valley gutters etc complete all as specified and as directed.
Material and labour for pre painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50 mm thick of any colour having tensile strength of 550 MPa as in roof covering/cladding to wall fixed with self tapping screws complete all as specified and as directed. NOTE :- (a) Approximate height of the work is up to 15 Mtr (b) There is no accessibility to the roof. (c) Necessary scaffolding for fixing valley gutter to be arranged by contractor without any extra cost.
Supply and fix plain galvanised mild steel sheeting, 0.50 mm thick, as in ridges, valley gutters with grade of zinc coating 275, fixed with clamps complete all as specified and as directed. NOTE :- (a) Approximate height of the work is up to 15 Mtr (b) There is no accessibility to the roof. (c) Necessary scaffolding for fixing valley gutter to be arranged by contractor without any extra cost.
Demolition of RCC as in Chajja of fourth storey building or height upto and including 10 mtr etc., including cutting old reinforcement to facilitate demolition complete all as specified and as directed.
Material and labour Reienforced cement concrete type B-1, (1:2:4), using 20 mm graded stone aggregate as in chajja of four storey building or height upto and including 15 mtr etc.including necessary form work / scaffolding etc complete all as specified and as directed
Supply and fix TMT steel bars 10mm dia and over for fourth storey building height or height upto and including 10 mtr etc., cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and as directed.
Dismantling water tanks and removing to store capacity exceeding 500 ltrs and not exceeding 1000 ltrs complete all as specified and as directed.
Supply and fix 1000 ltrs capacity multi layered Rotational mouldedd polyethylene water storage tanks (cylindrical vertical with closed top) ISI mark embossed on it, hoisted and fixed in position complete all as specified and ad directed.
Supply and fix in repairs 20mm gun metal, globe or gate valve with iron wheel head screwed both ends for iron pipe complete all as specified and as directed.
Supply and fix in repairs for 20 mm dia ball valve brass high pressure, with polythene float and fly nut complete screwed for iron pipe or brass ferrule complete all as specified and as directed
Taking down cement plaster of any description on walls concrete surfaces including racking out joints hacking for key scrubbing down with water remove dust debries / rubbish etc., complete all as specified and as directed.
Material and labour for rendering 15 mm thick in cement mortar (1:4) on fair faces of external brick work or concrete surfaces finishing the surfaces even and smooth without using extra cement complete all as specified and as directed.
Material and labour for 15 mm thick rendering in CM (1:6) on internal fair faces of brickwork or concrete surfaces and finished even and smooth without using extra cement all as specified and as directed.
Material and labour for applying two coats of oil emulsion distemper of approved tint over a coat of primer on newly plastered untreated surfaces of wall including preparation complete all as specified and as directed.
Material and labour for applying two or more coats of 100% premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new surfaces complete all as specified and as directed.
Taking up or down steel water tubing 15 mm dia (bore) including connection and fittings and refixing old steel tubing and connections in new or old position in walls, ceiling, floors, etc., complete all as specified and as directed.
Taking up or down steel water tubing 20 mm dia (bore) including connection and fittings and refixing old steel tubing and connections in new or old position in walls, ceiling, floors, etc., complete all as specified and as directed.
Taking up or down steel water tubing 25 or 32 mm dia (bore) including connection and fittings and refixing old steel tubing and connections in new or old position in walls, ceiling, floors, etc., complete all as specified and as directed.
Removing of debries (waste building material) dumped in side the ADE campus to a distance upto 10KM complete all as specified and as directed. NOTE :- Dumping site tobe decided by the contractor, department will not be responsible for any issue in connection with disposal.
Taking down collapsible steel gates / shutters consisting of channel, pickers, pivoted flat bars, top and bottom runners for servicing and checking its function including fixing only new wheels, top and bottom channels, cleaning and greasing of wheels and channels etc., complete and fixing in its original position complete area exc. 2.00 sqm and n.exc. 10 Sqm each complete all as specified and as directed.
Demolition of PCC of any description and in any position complete all as specified and as directed.
Material and labour water proofing treatment to the sunken portion with following steps :- (i) removing of exiting treatment including cleaning with wire brush. (ii) 15mm th plaster in CM (1:3) including using of WPC as per manufacturers instructions along with the entire perimeter of sunken portion. (iii) Applying two coats of brush bond of FOSROC or equivalent, second coat will be applied after complete drying of first coat or after 24 hours. (iv) Sunken floor kept ponded with water for minimum period of 48 hours. (v) one 450mm long 32 mm dia spout pipe of CPVC fixed to slope. NOTE :- BRUSH BOND shall be applied as per manufacturer's instructions.
Material and labour for Plain Cement Concrete (1:5:10), type E-2, using 40 mm graded crushed stone aggregate as in sunken slab filling etc., complete all as specified and as directed.
Material and labour for Plain Cement Concrete, (1:2:4), type B1, 30 mm thick using 20 mm graded stone aggregate as in flooring finished fair and even complete all as specified and as directed.
Material and labour for non skid ceramic coloured tiles 300 x 300 x 7 mm thick set and jointed in neat cement slurry and pointed in coloured cement to match as in floors over and including 15mm thick screed bed in cement mortar (1:6) for laying of floor finishes all as specified and as directed.
Supply and fix in repairs water closet (Orissa pattern) of size 580 x 440 mm white with integral foot rests excluding flushing cistern and flush pipe complete all as specified and as directed.
VP DEVELOPERS AND CONTRACTOR (BID ID -3427721)
SCION ENTERPRISES (BID ID -3425593)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .