Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.4 CrAccepted-AOC | ₹1.4 Cr | L1 | Accepted-AOC L1 |
| 2 | L2₹1.4 Cr+₹2.2 L (1.51%)Rejected-Finance | ₹1.4 Cr+₹2.2 L (1.51%) | L2 | Rejected-Finance L2 |
| 3 | L3₹1.5 Cr+₹6.9 L (4.88%)Rejected-Finance LONI BUDRUK TA RAHATA AHILYANAGAR 413705 | LONI BUDRUK | AHILYANAGAR | MAHARASHTRA | 413705 | ₹1.5 Cr+₹6.9 L (4.88%) | L3 | Rejected-Finance L3 |
| 4 | Rejected-Technical | - | - | Rejected-Technical All Technical Conditions are not Fullfilled |
Tender Value
₹1.4 Cr
Closing Date
21 Sept 2024, 2:00 pmClosed
President, Procurement Committee
Ahmednagar District Poultry Farmer Producer Company Limited, Ahmednagar
Construction of Hatchery Shed 278.78 Sq. Mtr, Feed Mill Shed 150.75 Sq. Mtr and Storage House (750 MT 424.26 Sq. Mtr)
2024_DOAWB_1076498_1
Nagar/NPoultry/Civil/2024/34
Open Tender
Civil Works
Item Rate
365 days
272/22, Jogeshwari Akhada, Rahuri, Dist. Ahmednaga
Please refer Tender documents.
2 documents required · 2 mandatory
₹1,000
Exempted
District Implementation Unit - Ahmednagar
30 Dec 2024
30 Aug 2024
23 Sept 2024
30 Aug 2024
21 Sept 2024
30 Aug 2024
10 Sept 2024
Amount
Construction of Hatchery Shed 278.78 Sq. Mtr, Feed Mill Shed (150.75 Sq. Mtr) & Storage House (750 MT; 424.26 Sq. Mtr)
Construction of Hatchery Shed 278.78 Sq. Mtr
Excavation for foundation in earth, soil of all types, sand, gravel and soft murum, including removing the excavated material up to a distance of 50 m.beyond the building area & stacking and spreading as directed, dewatering, preparing the bed for the foundation and necessary back filling, ramming, watering Including shoring and strutting etc. complete. (LIFT UPTO 1.5 M.) By Mechanical Means (PWD S.S.R. 22-23 Item Serial No.726 & Item No.21.02)
Excavation for foundation in Hard murum in cluding removing the excavated material upto adistance of 50 metres beyond the building area and stacking and spreading as directed, dewatering, preparing the bed for the foundation and necessary backfilling, ramming, watering including shoring and strutting etc. complete. (Lift from 1.5 to 3.0m.) By Mechanical Means (PWD S.S.R. 22-23 Item Serial No.732 & Item No.21.08)
Providing dry trap/ granite/ quartzite/ gneiss rubble stone soiling 15 cm to 20 cm thick including hand packing and compacting complete. Spec.No. : Bd.A.12 Page No. 264 ; (PWD S.S.R. 22-23 Item Serial No.757 & Item No.21.38)
Filling in plinth and floors with approved excavated material in 15cm. to 20cm. layersincluding watering and compacting etc. complete. (PWD S.S.R. 22-23 Item Serial No.755 & Item No.21.36)
Filling in plinth and floors with contractors material/ brought from outside and approved by Engineer in charge in layers of 15 cm to 20 cm including watering and compaction etc.complete. (PWD S.S.R. 22-23 Item Serial No.756 & Item No.21.37)
Providing and filling in the foundation with sand of approved quality including watering, compacting etc. complete. (PWD S.S.R. 22-23 Item Serial No.758 & Item No.21.39)
Providing and laying Cast in situ/ Ready Mix cement concrete in M-10 of trap/granite/quartzite/ gneiss metal for foundation and bedding including bailing out water, Steel centering, formwork, laying/pumping, compacting, roughening them if special finish is to be provided, finishing if required and curing complete ,with fully automatic microprocess or base dPLCwith SCADA enable dreversible Drum Type mixer/ concrete Batch mix plant (Panmixer) etc.complete. With fine aggregate (Crushed sand VSI Grade) (PWD S.S.R. 22-23 Item Serial No.732 & Item No.24.01)
Providing and laying in situ cement concrete of M-20 grade of trap / granite/quartzite/gneiss metal for R.C.C. work like raft, grillages, strips, foundations and footings of R.C.C.columns and steel stanchions including bailing-out water manually, including centering formwork of plywood / steel, compaction, covering newly laid concrete by gunny bag, plastic or tarpaulin, finishing the formed surface with cement morter 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening if special finish is to be provided and curing etc complete. (Excluding reinforcement) The cement mortar 1:3 plaster is considered for rendering uneven and honeycombed surface only. (Wooden planks / shuttering will not be allowed) Spec.No.:Bd.F.2 Page No. 298 /IS 456 (1978) (PWD S.S.R. 22-23 Item Serial No.841 & Item No.25.11)
Providing and laying Cast in situ/Ready Mix cement concrete M-20 of trap / granite /quartzite/ gneiss metal for R.C.C. columns as per detailed designs and drawing or as directed including steel centering, formwork, cover blocks, laying/pumping, compaction finishing the formed surfaces with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening if special finish is to be provided and curing etc. complete,(Excluding reinforcement and structural steel).with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Natural Sand / Crushed sand VSI Grade finely washed etc) (PWD S.S.R. 22-23 Item Serial No.846 & Item No.25.31)
Providing and laying Cast in situ/Ready Mix cement concrete M-20 of trap / granite /quartzite/ gneiss metal for R.C.C. beams and lintels as per detailed designs and drawings or as directed including steel centering, formwork, cover blocks, laying/pumping, compactionand roughening the surface if special finish is to be provided and curing etc. complete. (Excluding reinforcement and structural steel). with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Natural Sand / Crushed sand VSI Grade finely washed etc) (PWD S.S.R. 22-23 Item Serial No.851 & Item No.25.50)
Providing and fixing in position TMT - FE - 500 bar reinforcement of various diameters for R.C.C. pile caps, footings, foundations, slabs, beams columns, canopies, staircase, newels, chajjas, lintels pardis, copings, fins, arches etc. as per detailed designs, drawings and schedules. including cutting, bending, hooking the bars, binding with wires or tack welding and supporting as required complete. (PWD S.S.R. 22-23 Item Serial No.876 & Item No.26.33)
Providing Brick masonry in cement mortal 1.6 using second Class Burnt Bricks in foundation and plinth of inner walls/ in plinth of external walls including bailing out water manually, striking joints on unexposed faces ,watering and scaffolding complete Bd. G. 1, Page No.313, (PWD S.S.R. 22-23 Item Serial No.894 & Item No.27.01)
Providing second class Burnt Brick masonry with conventional/ I.S. type bricks in cement mortar 1:6 in superstructure including striking joints, raking out joints, watering and scaffolding etc. Complete. (PWD S.S.R. 22-23 Item Serial No.897 & Item No.27.05)
Providing sand faced plaster externally in cement mortar using approved screened sand, in all positions including base coat of 15 mm thick in cement mortar 1:4 using waterproofing compound at 1 kg per cement bag curing the same for not less than 2 days and keeping the surface of the base coat rough to receive the sand faced treatment 6 to 8 mm thick in cement mortar 1:4 finishing the surface by taking out grains and curing for fourteen days scaffolding etc.complete. (PWD S.S.R. 22-23 Item Serial No.968 & Item No.32.11)
Providing and fixing steel window of various sizes as per detailed drawing without hotdip zinc coating, with out ventilators, including fabricating/ glazing with plain/ obscured glass panels of approved type and quality, iron oxidised fixtures and fastenings, finishing with oil painting two coats complete (with guard bars12 mm square at 10 cm c/c.) (PWD S.S.R. 22-23 Item Serial No.1218 & Item No.39.20)
Providing and applying white-wash in one coat on old/ new plastered or masonry surfaces and asbestos cement sheets including scaffolding and preparing the surface by brushing and brooming down etc. complete. (PWD S.S.R. 22-23 Item Serial No.1102 & Item No. 36.02)
Providing and applying plastic emulsion paint of approved quality, colour and shade to old and new surfaces in two coats including scaffolding, preparing the surface. (excluding the primer coat) etc. complete. (PWD S.S.R. 22- 23 Item Serial No.1112 & Item No. 36.12)
Providing and fixing rolling shutter fabricated from steell at hsofminimum thickness 0.9mm with lock plate of 3.15 mm thickness reinforced with 35x35x5mm angle section fitted with sliding bolts and handles for both sides, deep M.S.channel section of depth and thickness not less than 65mm and 3.15mm respectively with hold fastarr angements, M.S.Bracket plate 300x300x3.15mm minimum size and shape with square bar, suspension shaft of minimum 32mm diameter, hood cover of M.S. sheet not less than 0.9mm thickness and of any size attopand safety device sincluding mechanical gear operation arrangement consisting of worm gear wheels and worms of high grade castir on or mild steel and one coat of redlead primer etc. complete.(I.S.62481979) (Without mechanical gear) (PWD S.S.R. 22-23 Item Serial No.1222 & Item No. 39.24)
Providing and laying in situ cement concrete M20 with tremix treatment for 100 mm thickness for flooring with groove cutting of 4mm wide and 20mm deep with necessary refilling with bitumen etc. complete. (PWD S.S.R. 22-23 Item Serial No.1022 & Item No. 33.30)
Providing structural steel work in trusses, other similar trussed purlins and members with all bracing, gusset plates etc. as per detailed designs and drawings or as directed including cutting, fabricating, hoisting, erecting fixing in position, Making riveted/ bolted/ welded connection and one coat of anti corrosive paint and over it 2 coats of oil painting approved quality and shade etc. complete. (PWD S.S.R. 22- 23 Item Serial No.824 & Item No. 23.04)
Providing and fixing colour coated Zincalume (R) AZ 150 (min150 gms /sq.mt. total on each side) profiled sheets for roofing. The feed materialis manufactured out of nominal 0.45mm Base Metal Thickness (BMT) (0.5mm TCT), Hi- strength steel with min. 550 MP a yield strength, metallic hot dip coated with Aluminium- Zinc alloy (55% aluminium 43.4% zinc 1.6% silicon) with COLOR BOND (R) steel quality super durable polyester paint coat (with in organic pigment). The paint shall have a total coating thickness of nominal 35um, comprising of nominal 25 um exterior coat on top surface and nominal 10um reverse coat on back surface. Profile sheet shall have nom. 950-1050 mm effective cover width and nominal 25-30 mm deep ribs with subtles quare flutingin the five panat nominal 180-250 mm center-to-center. The endrib shall be designed for anti- capillary groove. and return leg. The feed material should have coil manufacturers product details marked a regular interval. Including fasteners with min. fastened with min. 25um Zinc-Tinalloy coated, Hexhead, self-drilling screw etc. complete. (weight of profile 4.52Kilogram / Square Metre ). (PWD S.S.R. 22-23 Item Serial No.1179 & Item No. 38.34)
Turbo ventilator 24" MATERIAL RATES FOR SSR For Year 2021-22,Page no. 374, Building (Bd-R : Rofing and ceiling) (PWD S.S.R. 22-23 Item Page No.672 & Item No. 42)
Providing and fixing UPVC Roof made up of 3 layers roofing material of thickness 2mm having width of 1130mm and of required Length having Tensile strength not less than 330Kilo gram/ cm2, including fastening with self drilling screw having washers made of stainless steel etc. complete. (PWD S.S.R. 22-23 Item Serial No.1182 & Item No. 38.37)
Royalty Charges
Royalty Charges for sand
Royalty Charges for Rubble and HM
Material Testing Charges
Comp. Strength- Cube
Crush Metal-Basic Test
Gradation
Comboned Flakiness & Elongation of single metal
Cement-Fineness,consistency.Setting time,Compressive strength,Specific Gravity
Sand-Fineness Modulus,Silt Content
Water Absorption (Set of 5 Bricks), Compressive Strength( Set of 5 Bricks), Efflorescence (Set of 5 Bricks).
Electrification
Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 3 core 6 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL 7-1-9
Making trench in soft soil having 0.75 m depth and minimum 0.3 m width for laying provided cables up to voltage level of 1.1kV complete As per specification No. CW-EXN-CTR 16-1-1
Making trench in Hard murum/Tar road having 0.75 m depth and minimum 0.3mtr width as per IS for laying provided cables up to voltage level 1.1Kv cable complete as per specification No. CW-EXN-CTR 7-2-5
Supplying and erecting mains with 3x2.5 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places as per specification No: WG- MA/BW 5-12-1
Supplying & erecting CRCA sheet metal enclosures of 1.2mm thickness with 10A, 2 pin plug & earth socket and 10A, 3 pin plug top with 10A single pole MCB having rated short - circuit breaking capacity (Icn) 10kA complete erected on angle iron / GI frame. 5-4-10
Point wiring for light/fan/bell in 20 mm FRLS grade HMS PVC conduit with 1.5 sq.mm (2+1E) FRLSH grade copper wire with flush type switch and required accessories as per specification No: WG-PW/SW 1-7-3
Supplying & erecting 10-12W, 230V integral type LED Lamp suitable for B-22 /E-27 base. 2-8-11
Supplying and erecting integrated LED street light fitting 18 to 22W IP65 & IK08 class having single piece pressure die-cast aluminium housing,having system lumens output of Min. 1800 Lumens, min. efficacy of 100 lumen/W, CRI>70, CCT upto 6500K, THD<10%, p.f. >0.95, operating range of 140- 270V, inbuilt surge protection of 10 kV, Life class of 50,000 Hrs. at L70B50, including driver complete with 3 Years warranty as per specification No FGODF/ FLS2. 2-4-1
Supplying and erecting Street light bracket made from 40 mm. dia ‘B’ class G.I. Pipe, 0.6m. in length along with pole cap of 300 mm length and 80 mm dia duly welded with provided leads as per specification no. FG-BKT/BPC 2-7-2
Providng earthing with galvanized iron earth plate size 60 x 60 x 0.6 cm complete with all materials, testing & recording the results as per specification no. EA-EP 9-1-1
Providing pipe type earthing with 40mm. dia. G.I. pipe or 20 mm dia. G.I. Rod complete with all materials testing and recording the results as per specification no. EA-EP 9-1-4
Supplying, erecting & marking DPMCB 6A to 32A, C-series with rated short -circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW- SWR/MCB 5-3-6
Supplying, erecting & marking SPMCB 6A to 32A, B-series with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW- SWR/MCB 5-3-3
Supplying and erecting GI sheet 1.6 mm (16 SWG) having zinc coating of 350 microns with galvanization process compliance to IS 2629:1985 to be used for fabrication of boxes panel boards etc. including cutting, bending, drilling, welding, riveting etc. and painting with one coat of red lead paint and 2 coats of enamel paint. 6-1-6
Supplying and erecting marine (Waterproof) plywood 18/19 mm thick fixed to wall or on provided panel board with necessary materials such as screws, wall fasteners, supports, nut bolts etc. complete with compliance to IS 720:2010 6-1-14
Supplying & erecting triple pole and neutral distribution board (TPNDB), 3 pole/ 4 pole MCCB as incomer & outgoing SP MCB (12 poles) or TP MCB of 4 ways (12 poles), with door, 1.2mm thickness, surface/flush mounted, on iron/GI frame (vertical busbar type) as per specification no.SW- SWR/MCBDB1 5-4-15
Supplying & erecting G.I. pipe ‘A’ class 25 mm dia. erected for enclosing XLPE armoured cable on wall/pole as per specification no. CB-CE 7-6-1
Supplying & erecting G.I. pipe ‘A’ class 40 mm dia. erected for enclosing XLPE armoured cable on wall/pole as per specification no. CB-CE 7-6-2
Supplying and laying (including excavation of suitable width & depth up to 90 cm) 75 mm outside dia. double wall corrugated pipes (DWC) of HDPE for enclosing cable below ground/road surface, to required depth complete. 7-6-10
Supplying & erecting 18guage M.S. Box powder coated (4"x4") 3 way for mains connection. MR
Supplying & erecting single compression type brass cable glands for 3 to 4 core 6 sq mm /2 to 4 core 10 sq mm for XLPE armoured cable as per specification No.CB-GL 7-7-2
Supplying and erecting Ceiling rose / Batten holder / Slanting holder / hanging cord switch / hanging bell push / pendant holder bakelite base 6A. erected on filled polypropylene board or polished double wooden block/ PVC junction box. 1-5-7
Point wiring for independent plug in 20 mm metal conduit with 1.5 sq.mm (2+1E) FRLSH grade copper wire, flush type switch, earthing and required accessories as per specification No: WG- PW/SW 1-7-2
Wiring for plug on board with Switch socket surface/concealed type, copper wiring and earthing and with modular accessories as per specification No: WGPW/ CW 1-7-26
Supplying and erecting mains with 2x2.5 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places. as per specification No: WG- MA/BW 1-3-2
Supplying and erecting mains with 2x4 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places. as per specification No: WG- MA/BW 1-3-3
Supplying and erecting modular type D.P. switch 32A with indicator, duly erected on provided plate and box with wiring connections complete. 1-6-8
Supplying, erecting and marking double pole isolator only switch version of miniature circuit breaker of 40A with required wiring connections and lugs etc.in provided distribution board. 5-3-14
Supplying & erecting 3W, 230V integral type LED Lamp suitable for B-22 / E- 27 base. 2-8-9
Supplying and erecting IP65 and IK08 rated UV shielded polycarbonate waterproof and dustproof industrial grade LED fitting (4 feet) max. 36W with high transitivity diffuser with system lumens output of min. 4300 lumens , min. efficacy of 120 lumen/W, CRI>80, CCT upto 6500K, Beam Angle of 120 deg., Ripple<5%, THD<10%, p.f. >0.95, operating range of 120-270V, surge protection of 4 kV, Life class of 50,000 Hrs. at L70B50 , IP20 rated, including driver with auto cutoff & auto restart feature at 325V with end caps on PVC lock/wooden board with 3 years warranty. 2-2-1
Supplying and erecting regular/ standard model ceiling fan of 900 /1050 mm. sweep complete erected in position as per specification no. FG-FN/CF 2-10-2
Supplying and erecting ding dong / electronic musical type call bell with heavy duty coil suitable to operate on 230V A.C. supply erected on olished double wooden block/sunmica block of suitable size. 2-3-13
Supplying and erecting Street light bracket made from 25 mm. dia ‘B’ class G.I. Pipe, 0.6m. in length along with pole cap of 300 mm length and 80 mm dia duly welded with provided leads as per specification no. FG-BKT/BPC 2-7-1
Supplying & erecting CRCA sheet metal one way enclosures of 1.2mm thickness suitable for DP MCB /TP MCB/FP MCB/RCCB/RCBO complete erected on angle iron/GI frame. 5-4-13
Supplying, erecting and marking four pole isolators only switch version of miniature circuit breakers of 40A in provided distribution board. 5-3-18
Construction of Feed Mill Plant Shed Unit
Excavation for foundation in earth, soil of all types, sand,gravel and soft murum, including removing the excavated material up to a distance of 50 m.beyond the building area & stacking and spreading as directed, dewatering, preparing the bed for the foundation and necessary back filling, ramming, watering Including shoring and strutting etc. complete. (LIFT UPTO 1.5 M.) By Mechanical Means(PWD S.S.R. 22-23 Item Serial No.726 & Item No.21.02)
ExcavationforfoundationinHardmurumincludingremoving the excavated material upto adistance of 50 metresbeyondthebuildingareaandstackingandspreadingas directed, dewatering, preparing the bed for the foundation and necessarybackfilling,ramming,wateringincludingshoring andstruttingetc.complete.(Liftfrom1.5to3.0m.)By Mechanical Means (PWD S.S.R. 22-23 Item Serial No.732 & Item No.21.08)
Providing dry trap/ granite/ quartzite/ gneiss rubble stone soiling 15 cm to 20 cm thick including hand packing and compacting complete. Spec.No. : Bd.A.12 Page No. 264 ; (PWD S.S.R. 22-23 Item Serial No.757 & Item No.21.38)
Filling in plinth and floors withapprovedexcavatedmaterial in 15cm. to 20cm. layersincluding watering and compactingetc.complete.(PWD S.S.R.22-23Item SerialNo.755& Item No.21.36)
Filling in plinth and floors with contractors material/ broughtfromoutsideandapprovedbyEngineerinchargeinlayersof 15cmto20cmincludingwateringandcompactionetc.complete. (PWD S.S.R. 22-23 Item Serial No.756 & Item No.21.37)
Providing and filling in the foundation with sand of approved quality including watering, compacting etc. complete. (PWD S.S.R. 22-23 Item Serial No.758 & Item No.21.39)
Providing and laying Cast in situ/ Ready Mix cement concretein M-10 of trap/granite/quartzite/ gneiss metal for foundationandbeddingincludingbailingoutwater,Steelcentering,formwork,laying/pumping,compacting,rougheningthemif special finish is to be provided, finishing if required and curing complete,withfullyautomaticmicroprocessorbase dPLCwithSCADAenabledreversibleDrumTypemixer/concrete Batch mix plant (Panmixer) etc.complete. With fineaggregate (Crushed sand VSI Grade) (PWD S.S.R. 22-23 Item Serial No.732 & Item No.24.01)
Providing and laying in situ cement concrete of M-20 grade of trap / granite/quartzite/gneiss metal for R.C.C. worklike raft, grillages,strips,foundationsandfootingsofR.C.C.columns andsteelstanchionsincludingbailing-outwatermanually, including centering formwork of plywood / steel, compaction, coveringnewlylaidconcretebygunnybag,plasticor tarpaulin, finishing the formed surface with cement morter 1:3 ofsufficientminimumthicknesstogiveasmoothandeven surfaceorrougheningifspecialfinishistobeprovidedand curingetccomplete.(Excludingreinforcement)Thecement mortar1:3plasterisconsideredforrenderingunevenand honeycombed surface only. (Wooden planks / shuttering willnot be allowed) Spec.No.:Bd.F.2 Page No. 298 /IS 456 (1978) (PWD S.S.R. 22-23 Item Serial No.841 & Item No.25.11)
Providing and laying Cast in situ/Ready Mix cement concrete M-20oftrap/granite/quartzite/gneissmetalforR.C.C. columnsasperdetaileddesignsanddrawingorasdirected including steel centering, formwork, cover blocks, laying/pumping,compactionfinishingtheformedsurfaces withcementmortar1:3ofsufficientminimumthicknessto give a smooth and even surface or roughening if special finishistobeprovidedandcuringetc.complete,(Excluding reinforcement and structural steel).with fully automatic micro processorbasedPLCwith SCADAenabled reversibleDrum Typemixer/concreteBatchmixplant(Panmixer)etc. complete. Withfineaggregate (NaturalSand/Crushedsand VSIGradefinelywashedetc) (PWDS.S.R.22-23Item Serial No.846 & Item No.25.31)
Providing and laying Cast in situ/Ready Mix cement concreteM-20oftrap/granite/quartzite/gneissmetalforR.C.C. beamsandlintelsasperdetaileddesignsanddrawingsoras directedincludingsteelcentering,formwork,coverblocks, laying/pumping,compactionandrougheningthesurfaceifspecialfinishistobeprovidedandcuringetc.complete. (Excludingreinforcementandstructuralsteel).withfullyautomaticmicroprocessorbased PLCwith SCADA enabled reversibleDrumTypemixer/concreteBatchmixplant(Pan mixer)etc.complete.Withfineaggregate(NaturalSand/ Crushed sand VSI Grade finely washed etc)(PWD S.S.R. 22- 23 Item Serial No.851 & Item No.25.50)
Providing and fixing in position TMT - FE - 500 bar reinforcement of various diameters for R.C.C. pile caps, footings, foundations, slabs, beams columns, canopies,staircase, newels, chajjas, lintels pardis, copings, fins, archesetc. as per detailed designs, drawings and schedules. including cutting, bending, hooking the bars, binding with wires or tack welding and supporting as requiredcomplete. (PWD S.S.R.22-23 Item Serial No.876 & Item No.26.33)
Providing Brick masonry in cement mortal 1.6 using second Class Burnt Bricks in foundation and plinth of inner walls/ in plinth of external wallsincluding bailing out water manually, striking joints on unexposed faces ,watering and scaffolding completeBd. G. 1, Page No.313, (PWD S.S.R. 22-23 Item Serial No.894 & Item No.27.01)
ProvidingsecondclassBurntBrickmasonrywith conventional/I.S.typebricksincementmortar1:6in superstructureincludingstrikingjoints,rakingoutjoints,watering and scaffolding etc. Complete. (PWD S.S.R. 22-23Item Serial No.897 & Item No.27.05)
Providing sand faced plaster externally in cement mortar using approvedscreenedsand,inallpositionsincludingbasecoatof 15mmthickincementmortar1:4usingwaterproofing compound at 1 kg per cement bag curing the same for not less than 2 days and keeping the surface of the base coat rough toreceivethesandfacedtreatment6to8mmthickincement mortar 1:4 finishing the surface by taking out grains and curing forfourteendaysscaffoldingetc.complete.(PWDS.S.R.22- 23 Item Serial No.968 & Item No.32.11)
Providingandfixingsteelwindowofvarioussizesasper detaileddrawingwithouthotdipzinccoating,without ventilators, including fabricating/ glazing with plain/ obscured glasspanelsofapprovedtypeandquality,ironoxidisedfixturesandfastenings,finishingwithoilpainting twocoats complete (with guard bars12 mm square at 10 cm c/c.). (PWD S.S.R. 22-23 Item Serial No.1218 & Item No.39.20)
Providing and applying white-wash in one coat on old/ new plastered or masonry surfaces and asbestos cement sheets including scaffolding and preparing the surface by brushingand brooming down etc. complete. (PWD S.S.R. 22-23 Item Serial No.1102 & Item No. 36.02)
Providing and applying plastic emulsion paint of approved quality, colour and shade to old and new surfaces in two coats including scaffolding, preparing the surface. (excluding the primer coat) etc. complete. (PWD S.S.R. 22-23 Item Serial No.1112 & Item No. 36.12)
Providingandfixingrollingshutterfabricatedfromsteellat hsofminimumthickness0.9mmwithlockplateof3.15mm thicknessreinforcedwith35x35x5mmanglesectionfitted withslidingboltsandhandlesforbothsides,deep M.S.channelsectionofdepthandthicknessnotlessthan65mm and 3.15mm respectively with hold fastarr angements,M.S.Bracket plate 300x300x3.15mm minimum size and shape with square bar, suspension shaft of minimum 32mm diameter, hood cover of M.S. sheet not less than 0.9mm thickness and of anysizeattopandsafetydevicesincludingmechanicalgear operationarrangementconsistingofwormgearwheelsand wormsofhighgradecastironormildsteelandonecoatof redleadprimeretc.complete.(I.S.62481979)(Withoutmechanical gear)(PWD S.S.R. 22-23 Item Serial No.1222 & Item No. 39.24)
Providing and laying in situ cement concrete M20 with tremix treatment for 100 mm thickness for flooring with groovecutting of 4mm wide and 20mm deep with necessary refilling with bitumenetc. complete.(PWD S.S.R. 22-23 Item Serial No.1022 & Item No. 33.30)
Providing structural steel work in trusses, other similar trussed purlins and members with all bracing, gusset plates etc. as per detailed designs and drawings or as directed including cutting, fabricating,hoisting,erectingfixinginposition,Making riveted/bolted/weldedconnectionandonecoatofanti corrosivepaintandoverit2coatsofoilpaintingapproved qualityandshadeetc.complete.(PWDS.S.R.22-23Item Serial No.824 & Item No. 23.04)
Providing and fixing colourcoated Zincalume(R)AZ150 (min150gms/sq.mt.totaloneachside)profiledsheetsfor roofing.Thefeedmaterialismanufacturedoutofnominal 0.45mmBaseMetalThickness(BMT)(0.5mmTCT),Hi-strength steel with min. 550 MP a yield strength, metallic hotdipcoatedwithAluminium-Zincalloy(55%aluminium43.4%zinc1.6%silicon)withCOLORBOND(R)steelqualitysuperdurablepolyesterpaintcoat(withinorganic pigment).Thepaintshallhaveatotalcoatingthicknessof nominal 35um, comprising of nominal 25 um exterior coat ontopsurfaceandnominal10umreversecoatonbacksurface. Profilesheetshallhavenom.950-1050mmeffectivecover widthandnominal25-30mmdeepribswithsubtlesquare flutingin the five panat nominal 180-250 mm center-to-center. Theendribshallbedesignedforanti-capillarygroove.and return leg. The feed material shouldhave coil manufacturersproduct details marked a regular interval. Including fastenerswithmin.fastenedwithmin.25umZinc-Tinalloycoated, Hexhead, self-drilling screw etc. complete. (weight of profile4.52Kilogram/SquareMetre).(PWDS.S.R.22-23Item Serial No.1179 & Item No. 38.34)
Turbo ventilator 24" MATERIAL RATES FOR SSR For Year 2022-23,Pageno.374,Building(Bd-R:Rofingandceiling)
Providing and fixing UPVC Roof made up of 3 layers roofing materialofthickness2mmhavingwidthof1130mmandof required Length having Tensile strength not less than 330Kilo gram/ cm2, including fastening with self drilling screw having washers made of stainless steel etc. complete.(PWD S.S.R. 22- 23 Item Serial No.1182 & Item No. 38.37)
Royalty Charges
Royalty Charges for sand
Royalty Charges for Rubble and HM
Material Testing Charges
Comp.Strength-Cube(M10,M20,M25)
CrushMetal-BasicTest
Gradation
CombonedFlakiness&Elongationof single metal
Cement-Fineness,consistency.Setting time,Compressivestrength,SpecificGravity
Sand-FinenessModulus,SiltContent
Water Absorption (Set of 5 Bricks), CompressiveStrength(Setof5Bricks), Efflorescence (Set of 5 Bricks).
MurumInPlinth Plasticity Index
RUBBLE CrushingValue/CompressiveStrength, Water Absorption & Specific Gravity
STEEL Tensile strength Yield stress, ultimatetensile stress. %elongation, weight perrunning meter,Bend/Rebend test. (Set of 3Bars)UP to 16mm
ConcreteMixDesign(WithallTestsonbasic materials)
Electrification
Supplying,erecting&terminating FRXLPEinsulated, galvanisedsteelformedwirearmoured(strip)cable1100V, 3core6sq.mm.aluminiumconductorcompleteerected with glands &lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL7-1-9
Making trench in soft soil having 0.75 m depth and minimum 0.3 m width for laying provided cables up to voltage level of 1.1kV complete As per specification No. CW-EXN-CTR 16-1-1
Making trench in Hard murum/Tar road having 0.75 m depth and minimum 0.3mtr width as per IS for laying provided cablesuptovoltagelevel1.1Kvcablecompleteas per specification No. CW-EXN-CTR7-2-5
Supplyinganderectingmainswith3x2.5sq.mmFRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or anyother places as per specification No: WG-MA/BW5-12-1
Supplying&erectingCRCAsheetmetalenclosuresof 1.2mm thickness with 10A, 2 pin plug & earth socket and 10A,3pinplugtopwith10AsinglepoleMCBhavingrated short-circuitbreakingcapacity(Icn)10kAcompleteerected on angle iron / GI frame. 5-4-10
Point wiring for light/fan/bell in 20 mm FRLS grade HMS PVC conduit with 1.5 sq.mm (2+1E) FRLSH grade copper wire with flush type switch and required accessories as per specification No: WG-PW/SW 1-7-3
Supplying&erecting10-12W,230VintegraltypeLED Lamp suitable for B-22 /E-27 base. 2-8-11
Supplying and erecting integrated LED street light fitting 18 to 22W IP65 & IK08 class having single piece pressure die- castaluminiumhousing,havingsystemlumensoutputof Min. 1800 Lumens, min. efficacyof 100 lumen/W, CRI>70, CCT upto 6500K, THD<10%, p.f. >0.95, operating range of 140- 270V, inbuilt surge protection of 10 kV, Life class of 50,000Hrs.atL70B50,includingdrivercompletewith3 Years warrantyas per specification No FGODF/ FLS2.2-4- 1
SupplyinganderectingStreetlightbracketmadefrom40 mm. dia ‘B’ class G.I. Pipe, 0.6m. in length alongwith pole cap of 300 mm length and 80 mm dia duly welded with provided leads as perspecification no. FG-BKT/BPC2-7-2
Providng earthingwith galvanized iron earth plate size 60 x 60x0.6cmcompletewith allmaterials, testing&recording the results as per specification no. EA-EP9-1-1
Providingpipetypeearthingwith40mm.dia.G.I.pipeor20 mm dia. G.I. Rod complete with all materials testing and recording the results as per specification no. EA-EP9-1-4
Supplying,erecting&markingDPMCB6Ato32A,C-series with rated short -circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW- SWR/MCB5-3-6
Supplying, erecting & markingSPMCB 6A to 32A, B-series with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW- SWR/MCB5-3-3
Supplying and erecting GI sheet 1.6 mm (16 SWG) having zinc coating of 350 microns with galvanization process compliance to IS 2629:1985 to be used for fabrication of boxes panel boards etc. including cutting, bending, drilling, welding, riveting etc. and painting with one coat of red lead paint and 2 coats of enamel paint. 6-1-6
Supplying and erecting marine (Waterproof) plywood 18/19 mmthickfixedtowalloronprovidedpanelboardwith necessary materials such as screws, wall fasteners, supports, nut bolts etc. complete with compliance to IS 720:2010 6- 1-14
Supplying & erecting triple pole and neutral distribution board (TPNDB), 3 pole/ 4 pole MCCB as incomer & outgoing SP MCB (12 poles) or TP MCB of 4 ways (12 poles), with door, 1.2mm thickness, surface/flush mounted, on iron/GI frame (vertical busbar type) as per specification no.SW-SWR/MCBDB1 5-4-15
Supplying&erectingG.I.pipe‘A’class25mmdia.erected for enclosing XLPE armoured cable on wall/pole as per specification no. CB-CE 7-6-1
Supplying&erectingG.I.pipe‘A’class40mmdia.erected for enclosing XLPE armoured cable on wall/pole as per specification no. CB-CE 7-6-2
Supplyingandlaying(includingexcavationofsuitable width &depth up to 90 cm) 75 mmoutside dia. double wall corrugatedpipes(DWC)ofHDPEforenclosingcablebelow ground/road surface, to required depth complete. 7-6-10
Supplying &erecting CRCA sheetmetalonewayenclosures suitable for DP MCB /TP MCB /FP MCB erected on angle iron/GI frame complete. 5-4-13
Supplying & erecting single compression type brass cable glands for 3 to 4 core 6 sq mm /2 to 4 core 10 sq mm for XLPEarmouredcableasperspecificationNo.CB-GL7-7-2
SupplyinganderectingCeilingrose/Battenholder/Slanting holder / hanging cord switch / hanging bell push / pendantholderbakelitebase6A.erectedonfilled polypropyleneboardorpolisheddoublewoodenblock/ PVC junction box. 1-5-7
Point wiring for independent plug in 20 mm metal conduit with1.5sq.mm(2+1E)FRLSHgradecopperwire,flush typeswitch,earthingandrequiredaccessoriesasperspecification No: WG-PW/SW 1-7-2
Wiring for plug on board with Switch socket surface/concealed type, copper wiring and earthing and with modularaccessoriesasperspecificationNo:WGPW/CW1- 7-26
Supplyinganderectingmainswith2x2.5sq.mmFRLSH copper PVC insulated wire laid in provided conduit/trunking/insidepole/Busbarsoranyotherplaces.as per specification No: WG-MA/BW 1-3-2
Supplyinganderectingmainswith2x4sq.mmFRLSH copper PVC insulated wire laid in provided conduit/trunking/insidepole/Busbarsoranyotherplaces.as per specification No: WG-MA/BW 1-3-3
Supplying and erecting modular type D.P. switch 32A with indicator, duly erected on provided plate and box with wiring connections complete. 1-6-8
Supplying,erecting andmarking doublepole isolatoronly switchversionofminiaturecircuitbreakerof40Awith requiredwiringconnectionsandlugsetc.inprovided distribution board. 5-3-14
Supplying&erecting3W,230VintegraltypeLEDLamp suitable for B-22 / E- 27 base. 2-8-9
Supplyinganderecting IP65andIK08ratedUVshielded polycarbonatewaterproofanddustproofindustrialgrade LEDfitting(4feet)max.36Wwithhightransitivitydiffuser withsystemlumensoutputofmin.4300lumens,min. efficacyof120 lumen/W, CRI>80, CCT upto6500K, Beam Angleof120deg.,Ripple<5%,THD<10%,p.f.>0.95, operatingrangeof120-270V,surge protection of4kV, Life classof50,000Hrs.atL70B50,IP20rated,includingdriver withautocutoff&autorestartfeatureat325Vwithendcaps on PVC lock/wooden board with 3 years warranty. 2-2-1
Supplying and erecting regular/ standard model ceiling fan of900/1050mm.sweepcomplete erectedin positionasper specification no. FG-FN/CF 2-10-2
Supplying and erecting ding dong / electronic musical type call bellwithheavydutycoilsuitabletooperateon230V A.C. supplyerected on olished double woodenblock/sunmica block of suitable size. 2-3-13
Supplying and erecting Street light bracketmadefrom25 mm. dia ‘B’ class G.I. Pipe, 0.6m. in length alongwith pole cap of 300 mm length and 80 mm dia duly welded with provided leads as per specification no. FG-BKT/BPC 2-7-1
Supplying, erecting and marking four pole isolators only switch version of miniature circuit breakers of 40A in provided distribution board. 5-3-18
Construction of Storage House (750 MT; 424.26 Sq. Mtr)
Excavation for foundation in earth, soil of all types, sand, gravel and softmurum,includingremovingtheexcavatedmaterialuptoa distance of 50 m.beyond the building area & stacking and spreadingasdirected,dewatering,preparingthebedforthefoundationand necessarybackfilling,ramming,wateringIncludingshoringand strutting etc. complete. (LIFT UPTO 1.5 M.) By Mechanical Means (PWD S.S.R. 22-23 Item Serial No.726 & Item No.21.02)
Excavation for foundation in Hard murum in cluding removing the excavated material upto adistance of 50 metres beyond the building area and stacking and spreading as directed, dewatering, preparingthe bed for the foundation and necessary backfilling, ramming, watering including shoring and strutting etc. complete. (Lift from 1.5 to 3.0m.) By Mechanical Means (PWD S.S.R. 22-23 Item Serial No.732 & Item No.21.08)
Providing dry trap/ granite/ quartzite/ gneiss rubble stone soiling 15 cm to 20 cm thick including hand packing and compacting complete. Spec.No. : Bd.A.12 Page No. 264 ;(PWD S.S.R. 22-23 Item Serial No.757 & Item No.21.38)
Filling in plinth and floors with approved excavated material in15cm. to 20cm. layersincluding watering and compacting etc. complete. (PWD S.S.R. 22-23 Item Serial No.755 & ItemNo.21.36)
Filling in plinth and floors with contractors material/ brought from outside and approved by Engineer in charge in layers of 15 cm to 20 cm including watering and compaction etc.complete. (PWD S.S.R. 22-23 Item Serial No.756 & Item No.21.37)
Providingandfillinginthefoundationwithsandofapproved quality including watering, compacting etc. complete. (PWD S.S.R. 22-23 Item Serial No.758 & Item No.21.39)
Providing and laying Cast in situ/ Ready Mix cement concrete in M-10 of trap/granite/quartzite/ gneiss metal for foundation and bedding including bailing out water, Steel centering, formwork, laying/pumping, compacting, roughening them if special finish is tobeprovided,finishingifrequiredandcuringcomplete,withfully automaticmicroprocessorbasedPLCwithSCADAenabledreversible Drum Type mixer/ concrete Batch mix plant (Panmixer) etc.complete. With fine aggregate (Crushed sand VSI Grade) (PWD S.S.R. 22-23 Item Serial No.732 & Item No.24.01)
Providing and laying in situ cement concrete of M-20 grade of trap / granite/quartzite/gneissmetalforR.C.C.worklikeraft,grillages, strips,foundationsandfootingsofR.C.C.columnsandsteel stanchions including bailing-out water manually, including centering formworkofplywood/steel,compaction,coveringnewlylaidconcretebygunnybag,plasticortarpaulin,finishingtheformed surface with cement morter 1:3 of sufficient minimum thickness togive a smooth and even surface or rougheningif special finish is tobeprovidedandcuringetccomplete.(Excludingreinforcement) Thecementmortar1:3plasterisconsideredforrenderinguneven and honeycombed surface only. (Wooden planks / shuttering will not beallowed)Spec.No.:Bd.F.2PageNo.298/IS456(1978)(PWD S.S.R. 22-23 Item Serial No.841 & Item No.25.11)
Providing and laying Cast in situ/Ready Mix cement concrete M-20oftrap/granite/quartzite/gneissmetalforR.C.C.columnsasper detailed designs and drawing or as directed including steel centering, formwork, cover blocks, laying/pumping, compaction finishing theformedsurfaceswithcementmortar1:3ofsufficientminimum thickness to give a smooth and even surface or roughening if special finishistobeprovidedandcuringetc.complete,(Excluding reinforcementandstructuralsteel).withfullyautomaticmicro processor based PLC with SCADA enabled reversible Drum Typemixer/concreteBatchmixplant(Panmixer)etc.complete.With fineaggregate(NaturalSand/CrushedsandVSIGradefinelywashedetc) (PWDS.S.R.22-23ItemSerialNo.846&Item No.25.31)
Providing and laying Cast in situ/Ready Mix cement concrete M-20of trap / granite /quartzite/ gneiss metal for R.C.C. beams and lintelsas per detailed designs and drawings or as directed including steel centering, formwork, cover blocks, laying/pumping, compactionand roughening the surface if special finish is to be provided and curing etc. complete. (Excluding reinforcement and structural steel). with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Natural Sand / Crushed sand VSI Grade finely washedetc)(PWD S.S.R. 22-23Item Serial No.851& Item No.25.50)
Providing and laying Cast in situ/Ready Mixcement concrete in M-20 of trap / granite/gneiss/ quartzite metal for R.C.C. fins of required thicknessinpositionasshownonthedrawingsorasdirectedby Engineer -in-charge including steel centering, plywood / steel formwork,steelprops,laying/pumping,compaction,finishinguneven andhoneycombedsurfacewithC.M.1:3ofsufficientminimum thicknesstogiveasmoothandevensurfaceorrougheningthe surface if special finish is to be provided and curing etc. complete.(Excludingreinforcement,includingcoverblock)Newlylaid concrete shall be covered by gunny bag, plastic, tarp aulin etc. withfullyautomaticmicroprocessorbasedPLCwithSCADAenable dreversible Drum Type mixer/ concrete Batchmix plant (Panmixer)etc.complete.Withfineaggregate(CrushedsandVSIGrade)(PWD S.S.R. 22-23 Item Serial No.874 & Item No.26.31)
Providing and casting in situ cement concrete of M-20 grade of trap granite / quartzite / gneiss metal for R.C.C. slabs and landings as per detailed designs and drawings or as directed including fixing plastic cover block of requird size at 27 Nos in per 10 Sqm to reinforcement to give a clear cover of 15mm in RCC slabs, fixing fan hook box of 100mmdiameterPVCorMSmaterialwithrequireddepthwith holes or notches as required, bottom with 12mm diameter M.S. barbendtoshapewithhookedendsforfanhookandpaintingtoexposed surface, centering, formwork of steel, compaction, covering newly laid concrete by gunny bag, plastic or tarpaulin, finishing the formedsurfacewithcementmortar1:3ofsufficientminimumthickness to give a smooth and even surface or roughening if special finishistobeprovidedandcuringetc.complete.(Excluding reinforcement.Thecementmortar1:3plasterisconsideredforrendering uneven and honeycombed surface only. Wooden planks / shuttering will not be allowed). Bd.F.8 Page No. 302 / IS 456:2000(PWD S.S.R. 22-23 Item Serial No.856 & Item No.25.70)
Providing andfixing inpositionTMT-FE -500barreinforcement of various diameters for R.C.C. pile caps, footings, foundations,slabs, beams columns, canopies, staircase, newels, chajjas, lintels pardis,copings,fins,archesetc.asperdetaileddesigns,drawings and schedules. including cutting, bending, hooking the bars, binding with wires or tack welding and supporting as required complete. (PWD S.S.R. 22-23 Item Serial No.876 & Item No.26.33)
Providing dry rubble stone pitching 23cm (about 9) thick includingall material, quarry spalls, labour etc.complete. (PWD S.S.R. 22-23 Item Serial No.109 & Item No.2.34)
Providing Brick masonry in cement mortal 1.6 using second Class Burnt Bricks in foundation and plinth of inner walls/ in plinth of external wallsincluding bailing out water manually, striking jointson unexposed faces ,watering and scaffolding completeBd. G. 1, Page No.313, (PWD S.S.R. 22-23 Item Serial No.894 & Item No.27.01)
Providing second class Burnt Brick masonry with conventional/ I.S. type bricks in cement mortar 1:6 in superstructure including striking joints, raking out joints, watering and scaffolding etc. Complete. (PWD S.S.R. 22-23 Item Serial No.897 & Item No.27.05)
Providingsandfacedplasterexternallyincementmortarusingapprovedscreenedsand,inallpositionsincludingbasecoatof15 mm thick in cement mortar 1:4 using waterproofing compound at 1kgpercementbagcuringthesamefornotlessthan2daysand keeping the surface of the base coat rough to receive the sand facedtreatment 6 to 8 mm thick in cement mortar 1:4 finishing the surface bytakingoutgrainsandcuringforfourteendaysscaffolding etc.complete.(PWDS.S.R.22-23ItemSerialNo.968&Item No.32.11)
Providing internal cement plaster 20mm thick in two coats in cement mortar 1:3 without neeru finish to concrete or brick surfaces, in all positions including scaffolding and curing complete.(PWD S.S.R.22-23 Item Serial No.967 & Item No.32.08)
Providingneerufinishtoplasteredsurfacesinallpositions including scaffolding and curing etc. complete.(PWD S.S.R. 22-23Item Serial No.971 & Item No.32.15)
Providing and applying primer coat for internal wall surfaces and ceilings including scaffolding etc. complete.(PWD S.S.R. 22-23Item Serial No.1095 & Item No.35.21)
Providing and applying washable oil-bound distemper of approvedcolourandshadetooldandnewsurfacesintwocoatsincluding scaffolding, preparing the surfaces. (excluding the primer coat.) etc. complete.(PWDS.S.R.22-23ItemSerialNo.1111&Item No.36.11)
Providing and fixing steel ventilat or fully glazed partly fixed as per detailed drawing with hot dip zinc coating including fabricating glazingwithplain/obscuredglasspans5mmthickandapproved type quality and iron oxidized fixtures and fastening with guardsquare bars 12mm 10cmc /cand oil painting 2coats etc. complete. (PWD S.S.R. 22-23 Item Serial No.1228 & Item No. 39.30)
Providingandapplyingwhite-washinonecoatonold/new plastered or masonry surfaces and asbestos cement sheets including scaffoldingandpreparingthesurfacebybrushingandbrooming downetc.complete.(PWDS.S.R.22-23ItemSerialNo.1102& Item No. 36.02)
Providing and applying plastic emulsion paint of approved quality, colour and shade to old and new surfaces in two coats including scaffolding, preparing the surface. (excluding the primer coat) etc. complete. (PWD S.S.R. 22-23 Item Serial No.1112 & Item No. 36.12)
Providingandfixingrollingshutterfabricatedfromsteellat hsofminimumthickness0.9mmwithlockplateof3.15mm thicknessreinforcedwith35x35x5mmanglesectionfittedwith sliding bolts and handles for both sides, deep M.S.channel section of depthandthicknessnotlessthan65mmand3.15mmrespectively withholdfastarrangements,M.S.Bracketplate300x300x3.15mm minimumsizeandshapewithsquarebar,suspensionshaftofminimum32mmdiameter,hoodcoverofM.S.sheetnotlessthan 0.9mm thickness and of any size attopand safety device sincludingmechanicalgearoperationarrangementconsistingofwormgear wheels and worms of high grade castir on or mild steel and one coatof redlead primer etc. complete.(I.S.62481979) (Without mechanical gear)(PWD S.S.R. 22-23 Item Serial No.1222 & Item No. 39.24)
ProvidingandlayinginsitucementconcreteM20withtremix treatment for 100 mm thickness for flooring with groove cutting of4mmwideand20mmdeepwithnecessaryrefillingwithbitumen etc.complete.(PWDS.S.R.22-23ItemSerialNo.1022&Item No. 33.30)
Providing fine cement finish 1.5 mm thick over green plaster surface includingscaffoldingcuringetc.complete.(PWDS.S.R.22-23 Item Serial No.977 & Item No. 32.21)
Providing structural steel work in trusses, other similar trussedpurlins and members with all bracing, gusset plates etc. as perdetailed designs and drawings or as directed including cutting, fabricating, hoisting, erecting fixing in position, Making riveted/ bolted/ welded connection and one coat of anti corrosive paint and over it 2 coats of oil painting approved quality and shade etc. complete. (PWD S.S.R. 22-23 Item Serial No.824 & Item No.23.04)
Providing and fixing colour coated Zincalume (R) AZ 150 (min150 gms /sq.mt. total on each side) profiled sheets for roofing. The feedmaterialismanufacturedoutofnominal0.45mmBaseMetal Thickness (BMT) (0.5mm TCT), Hi-strength steel with min. 550 MPa yield strength, metallic hot dip coated with Aluminium- Zinc alloy (55% aluminium 43.4% zinc 1.6% silicon) with COLOR BOND (R) steelqualitysuperdurablepolyesterpaintcoat(withinorganic pigment). The paint shall have a total coating thickness of nominal35um, comprising of nominal 25 um exterior coat on top surface and nominal 10um reverse coat on back surface. Profile sheet shall have nom.950-1050mmeffectivecoverwidthandnominal25-30mm deepribswithsubtlesquareflutinginthefivepanatnominal180- 250mmcenter-to-center.Theendribshallbedesignedforanti-capillary groove. and return leg. The feed material should have coilmanufacturersproductdetailsmarkedaregular interval.Including fasteners with min. fastened with min. 25um Zinc-Tinalloy coated,Hexhead,self-drillingscrewetc.complete.(weightofprofile 4.52Kilogram/SquareMetre).(PWDS.S.R.22-23ItemSerial No.1179 & Item No. 38.34)
Turbo ventilator 24" MATERIAL RATES FOR SSR For Year 2022- 23, Page no. 374, Building (Bd-R : Rofing and ceiling)
ProvidingandfixingUPVCRoofmadeupof3layersroofing material of thickness 2mm having width of 1130mm and of required LengthhavingTensilestrengthnotlessthan330Kilogram/cm2, including fastening with self drilling screw having washers made of stainlesssteeletc.complete.(PWDS.S.R.22-23ItemSerial No.1182 & Item No. 38.37)
Royalty Charges
Royalty Charges for sand
Royalty Charges for Rubble and HM
Material Testing Charges
Comp.Strength-Cube (M10,M20)
CrushMetal-BasicTest
Gradation
Comboned Flakiness&Elongation ofsingle metal
Cement-Fineness,consistency.Setting time,Compressivestrength,SpecificGravity
Sand-FinenessModulus,SiltContent
Water Absorption (Set of 5 Bricks), CompressiveStrength(Setof5Bricks), Efflorescence(Setof5Bricks).
MurumInPlinth Plasticity Index
RUBBLE CrushingValue/CompressiveStrength, Water Absorption & Specific Gravity
STEEL Tensile strength Yield stress, ultimate tensilestress. %elongation, weight per runningmeter,Bend/Rebend test. (Set of 3 Bars)UP to 16mm
Concrete Mix Design (With all Tests on basicmaterials)
Internal Bituminous roads For WareHouse
Clearing grass and removal of rubbish up to a distance of50 metres outside the periphery of the area. (PWD S.S.R. 22-23 Item Serial No.85 & Item No.2.07)
Providing, laying, spreading and compacting stone aggregates of specific sizes to water bound macadam specification including spreading in uniform thickness,hand packing to proper grade and camber, applying and brooming requisite type of screening/ binding Materials to fill up the interstices of coarse aggregate, watering and compacting with Vibratory roller. to the required density. By Mechanical Means - Grading I(Using Screening Type A (13.2) mm Aggregate) (PWD S.S.R. 22-23 Item Serial No.129 & Item No.3.18)
Providing, laying, spreading and compacting stone aggregates of specific sizes to water bound macadam specification including spreading in uniform thickness,hand packing to proper grade and camber, applying and brooming requisite type of screening/ binding Materials to fill up the interstices of coarse aggregate, watering and compacting with vibratory roller to the required density.ByMechanicalMeans-GradingII(UsingScreening Type B (11.2 mm) Aggregate) (PWD S.S.R. 22-23 Item Serial No.131 & Item No. 3.20)
Providingandconstructing75mm.thickModified PenetrationMacadam(MPM)road surfaceincludingall materials, preparing the existing road surface, spreading40mm.stonemetallayers100%crusher brokenmetalwithconicalcrusherplantheatingand spraying the bitumen of specified grade @ 2 Kilogram/Square Metre, spreading 12 mm.size chips compactingwiththreewheelstaticrollerhaving weight 8 to 10 MT. to achive the desired degree of compactionas perTechnicalSpecificationClause506 etc. complete. (VG-30 bulk bitumen ) (PWD S.S.R. 22-23 Item Serial No.146 & Item No.3.35a)
Open Graded Premix Surfacing- Providing and Laying OGC20mm thicknesscomposedof13.2mmto5.6 mmaggregatespremixedwithbituminousbinder@ 1.56Kg/Sqm transportedtositewithVTS,laidovera previouslypreparedsurface,finishedtotherequiredgrade,level,alignment,androllingtoachievethe desiredcompactionbutexcludingprime/tackand Sealcoat.ForBitumenofspecifiedgrade--USING drummixtypehotmixplant,PaverandVibratory roller(OverMPMSurface)(VG-30bulkGrade 60/70)(PWDS.S.R.22-23Item SerialNo.168&Item No.4.12)
9 MM SEAL COAT:Providingand layingof TypeA 9 mmpremixsealcoatwithHMPofSqmapropriatecapacitycrushedstonechiping6.7mmsizeandpenetrationbitumenof [email protected]/Sq.m, preparingexistingroadsurfacebymechanicalmeans, spreadingchips and rolling, by static rollerhaving weight8to10MTetc.complete.(VG-30bulkGrade60/70) (PWD S.S.R. 22-23 Item Serial No.161 & Item No.4.01)
Supplying hard murum/ kankar at the road site, including conveying and stacking complete. (PWD S.S.R. 22-23 Item Serial No.103 & Item No.2.29a)
Spreading hard murum/ soft murrum/ gravel or kankar for side width complete. (PWD S.S.R. 22-23 Item Serial No.105 & Item No.2.30)
Compacting the hard murum side widths including layingin layers on each side with vibratory roller including artificial watering etc. complete. (PWD S.S.R. 22-23 Item Serial No.106 & Item No.2.31)
Royalty Charges
ROYALTY CHARGES
Material Testing Charges
PlasticityIndexforMurum
CombinedFlakiness&Elongationofsingle Metal
Grardation
CombinedFlakiness&Elongationofsingle
BinderContent
B. M. Mix Design with all Tests on aggregate(Excludingbitumen)(Testingof Bitumen shall be seperately Charged)
Penetration,SofteningPoint,Flash&Fire Point, Specific Gravity
ExtractionTest.(Bituminousmix)
Viscocity
Electrification
Supplying,erecting&terminatingFRXLPEinsulated, galvanisedsteelformedwirearmoured(strip)cable1100V, 3core6sq.mm.aluminiumconductorcompleteerected with glands &lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL7-1-9
Making trench in soft soil having 0.75 m depth and minimum 0.3 m width for laying provided cables up to voltage level of 1.1kV complete As per specification No. CW-EXN-CTR 16-1-1
Making trench in Hard murum/Tar road having 0.75 m depth and minimum 0.3mtr width as per IS for laying provided cablesuptovoltagelevel1.1Kvcablecompleteas per specification No. CW-EXN-CTR7-2-5
Supplyinganderectingmainswith3x2.5sq.mmFRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or anyother places as per specification No: WG-MA/BW5-12-1
Supplying&erectingCRCAsheetmetalenclosuresof 1.2mm thickness with 10A, 2 pin plug & earth socket and 10A,3pinplugtopwith10AsinglepoleMCBhavingrated short-circuitbreakingcapacity(Icn)10kAcompleteerected on angle iron / GI frame. 5-4-10
Point wiring for light/fan/bell in 20 mm FRLS grade HMS PVC conduit with 1.5 sq.mm (2+1E) FRLSH grade copper wire with flush type switch and required accessories as per specification No: WG-PW/SW 1-7-3
Supplying & erecting10-12W,230VintegraltypeLED Lamp suitable for B-22 /E-27 base. 2-8-11
Supplying and erecting integrated LED street light fitting 18 to 22W IP65 & IK08 class having single piece pressure die- castaluminiumhousing,havingsystemlumensoutputof Min. 1800 Lumens, min. efficacyof 100 lumen/W, CRI>70, CCT upto 6500K, THD<10%, p.f. >0.95, operating range of 140- 270V, inbuilt surge protection of 10 kV, Life class of 50,000Hrs.atL70B50,includingdrivercompletewith3 Years warrantyas per specification No FGODF/ FLS2.2-4- 1
Supplying and erectingStreetlightbracketmadefrom40 mm. dia ‘B’ class G.I. Pipe, 0.6m. in length alongwith pole cap of 300 mm length and 80 mm dia duly welded with provided leads as perspecification no. FG-BKT/BPC2-7-2
Providng earthingwith galvanized iron earth plate size 60 x 60x0.6cmcompletewith allmaterials, testing&recording the results as per specification no. EA-EP9-1-1
Providingpipetypeearthingwith40mm.dia.G.I.pipeor20 mm dia. G.I. Rod complete with all materials testing and recording the results as per specification no. EA-EP9-1-4
Supplying,erecting&markingDPMCB6Ato32A,C-series with rated short -circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW- SWR/MCB5-3-6
Supplying, erecting&markingSPMCB 6A to 32A, B-series with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW- SWR/MCB5-3-3
Supplying and erecting GI sheet 1.6 mm (16 SWG) having zinc coating of 350 microns with galvanization process compliance to IS 2629:1985 to be used for fabrication of boxes panel boards etc. including cutting, bending, drilling, welding, riveting etc. and painting with one coat of red lead paint and 2 coats of enamel paint. 6-1-6
Supplying and erecting marine (Waterproof) plywood 18/19 mmthickfixedtowalloronprovidedpanelboardwith necessary materials such as screws, wall fasteners, supports, nut bolts etc. complete with compliance to IS 720:2010 6- 1-14
Supplying & erecting triple pole and neutral distribution board (TPNDB), 3 pole/ 4 pole MCCB as incomer & outgoing SP MCB (12 poles) or TP MCB of 4 ways (12 poles), with door, 1.2mm thickness, surface/flush mounted, on iron/GI frame (vertical busbar type) as per specification no.SW-SWR/MCBDB1 5-4-15
Supplying&erectingG.I.pipe‘A’class25mmdia.erected for enclosing XLPE armoured cable on wall/pole as per specification no. CB-CE 7-6-1
Supplying&erectingG.I.pipe‘A’class40mmdia.erected for enclosing XLPE armoured cable on wall/pole as per specification no. CB-CE 7-6-2
Supplyingandlaying(includingexcavationofsuitable width &depth up to 90 cm) 75 mmoutside dia. double wall corrugatedpipes(DWC)ofHDPEforenclosingcablebelow ground/road surface, to required depth complete. 7-6-10
Supplying&erectingCRCAsheetmetalonewayenclosures suitable for DP MCB /TP MCB /FP MCB erected on angle iron/GI frame complete. 5-4-13
Supplying & erecting single compression type brass cable glands for 3 to 4 core 6 sq mm /2 to 4 core 10 sq mm for XLPEarmouredcableasperspecificationNo.CB-GL7-7-2
SupplyinganderectingCeilingrose/Battenholder/Slanting holder / hanging cord switch / hanging bell push / pendantholderbakelitebase6A.erectedonfilled polypropyleneboardorpolisheddoublewoodenblock/ PVC junction box. 1-5-7
Point wiring for independent plug in 20 mm metal conduit with1.5sq.mm(2+1E)FRLSHgradecopperwire,flush typeswitch,earthingandrequiredaccessoriesasperspecification No: WG-PW/SW 1-7-2
Wiring for plug on board with Switch socket surface/concealed type, copper wiring and earthing and with modularaccessoriesasperspecificationNo:WGPW/CW1- 7-26
Supplyinganderectingmainswith2x2.5sq.mmFRLSH copper PVC insulated wire laid in provided conduit/trunking/insidepole/Busbarsoranyotherplaces.as per specification No: WG-MA/BW 1-3-2
Supplyinganderectingmainswith2x4sq.mmFRLSH copper PVC insulated wire laid in provided conduit/trunking/insidepole/Busbarsoranyotherplaces.as per specification No: WG-MA/BW 1-3-3
Supplying and erecting modular type D.P. switch 32A with indicator, duly erected on provided plate and box with wiring connections complete. 1-6-8
Supplying,erecting andmarking doublepole isolatoronly switchversionofminiaturecircuitbreakerof40Awith requiredwiringconnectionsandlugsetc.inprovided distribution board. 5-3-14
Supplying&erecting3W,230V integral type LED Lamp suitable for B-22 / E- 27 base. 2-8-9
SupplyinganderectingIP65andIK08ratedUVshielded polycarbonatewaterproofanddustproofindustrialgrade LEDfitting(4feet)max.36Wwithhightransitivitydiffuser withsystemlumensoutputofmin.4300lumens,min. efficacyof120 lumen/W, CRI>80, CCT upto6500K, Beam Angleof120deg.,Ripple<5%,THD<10%,p.f.>0.95, operatingrangeof120-270V,surge protection of4kV, Life classof50,000Hrs.atL70B50,IP20rated,includingdriver withautocutoff&autorestartfeatureat325Vwithendcaps on PVC lock/wooden board with 3 years warranty. 2-2-1
Supplying and erecting regular/ standard model ceiling fan of900/1050mm.sweepcomplete erectedin positionasper specification no. FG-FN/CF 2-10-2
Supplying and erecting ding dong / electronic musical type callbellwithheavydutycoilsuitabletooperateon230V A.C. supplyerected on olished double woodenblock/sunmica block of suitable size. 2-3-13
SupplyinganderectingStreetlightbracketmadefrom25 mm. dia ‘B’ class G.I. Pipe, 0.6m. in length alongwith pole cap of 300 mm length and 80 mm dia duly welded with provided leads as per specification no. FG-BKT/BPC 2-7-1
Supplying, erecting and marking four pole isolators only switch version of miniature circuit breakers of 40A in provided distribution board. 5-3-18
ESHS COMPLIANCE
Management Strategies and Implementation Plan (MSIP) to manage Environmental, Social , Health and Safety (ESHS) Risk and ESHS Code of Conduct
BAPUSAHEB KISAN KANDEKAR (BID ID -6161096)
M/s VIRA INFRASTRUCTURE (BID ID -6161028)
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .