Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹3.3 LAccepted-AOC 24C GOABAGAN LANE KOLKATA 700 006 | KOLKATA | KOLKATA | WEST BENGAL | 700006 | L1 | Accepted-AOC AOC issued | |
| 2 | L2₹3.4 L+₹13,113 (3.97%)Rejected-Finance 28 SAMBHU BABU LANE KOLKATA 700014 | KOLKATA | KOLKATA | WEST BENGAL | 700014 | L2 | Rejected-Finance That the Bid is not L1 | |
| 3 | L3₹3.5 L+₹14,613 (4.42%)Rejected-Finance | L3 | Rejected-Finance That the Bid is not L1 | |
| 4 | L4₹4.1 L+₹78,527.40 (23.8%)Rejected-Finance 000 RATH TALA UKHRA UKHRA UKHRA BARDHAMAN WEST BENGAL 713363 | PASCHIM BARDHAMAN | WEST BENGAL | 713363 | L4 | Rejected-Finance That the Bid is not L1 | |
| 5 | L5₹4.1 L+₹83,073 (25.1%)Rejected-Finance 10 11 UMACHARAN BHATTACHARYA LANE SHIBPUR HOWRAH 711101 | HOWRAH | HOWRAH | WEST BENGAL | 711101 | L5 | Rejected-Finance That the Bid is not L1 |
Tender Value
Refer Docs
EMD Value
₹8,260
Closing Date
26 Sept 2024, 1:00 pmClosed
Assistant Engineer, KMC Electrical Sub-Division
OFFICE OF THE ASISTANT ENGINEER Kolkata Medical College Electrical Sub-Division, P.W.Dte.Green Building, MCH Campus 88, College Street, Kolkata-700073.
Installation of compound lights along with necessary electrical installation work within the premises of School of Tropical Medicine, Kolkata.
2024_WBPWD_751339_1
WBPWD/AE/KMCESD/NIQ-94/24-25
Open Tender
ELECTRICAL WORKS ORG
Item Rate
15 days
Kolkata
Please refer Tender documents.
5 documents required · 5 mandatory
₹8,260
16 Apr 2025
13 Sept 2024
30 Sept 2024
20 Sept 2024
26 Sept 2024
20 Sept 2024
Amount
E.I WORK Compound Lighting Arrangement :: Supply of 230V 5700 K 21000lm Luminous Efficacy (rated) (Nom) 140 lm/W Aluminum die cast IP66 [Dust penetration-protected, jet-proof]LED Street Light Luminaries complete with all accessories. (corrosponding to Mk. Philips, Cat No. BRP504 LED 210 CW R3C PSU S1/ equivalent of Havells/ Wipro).
Fixing only outdoor / street light type fluorescent light fitting complete with all accessories to be fixed/projected from the wall of the building incl. making holes to building, S&F 40 mm dia GI pipe (ISI-Medium) 1.50 mts. average length, with GI socket at one end and thread at the other end & suitable bend to house the fitting & making necy. connections with S&F necy. length of 1.5 sqmm PVC insulated single core stranded annealed copper wire and making connections as required and mending good damages to wall and painting.
S & Erection of PVC water proof loop Box (Mk. Syntex code; GSMB 2520) of size 8" x 10" with 100A, 4 pole stud type terminal block, 15A kitkat fuse & NL, to be fixed on bakelite/porcelin insulator, having hinged PVC cover 4mm thick, rubber gasket lining, mechanical locking arrangement to be concealed in wall as per direction of EIC.
Supply and installation of 1-Phase timer in double door SPN DB (2+10) way providing incoming and outgoing copper wires and other accessories. The interconnection should be made by 4 sq.mm. copper wires. The box should be painted by powder coated paint. a) 25A DP MCB -1 No. (b)Analog/Digital time switch - 1 No. (c) 2-pole 30A single phase power contactor, - 1 No. (d) Add-on auxiliary contact block(1 NO+1 NC) -1 no (e) 60A capacity 3 way AC/DC Epoxy terminal block.- 1 No. (f) Indicator Lamp (ESBEE make)-2 Nos. (g) Toggle switch,(ON_OFF_ON)- 1 No. (h) Steel Key Lock – 1 No. (Make- LK /ABB)
Supply of cables :---Supplying and Delivery of following sizes Al. armoured PVC/XLPE cable (Havells/RR kable/KEI) as mentioned below : a. 2 core 10 sqmm
Laying of cables :- Laying of 2 core 10 sqmm Al. armoured PVC/XLPE cable (Havells/Glostar/KEI) with 1X10 SWG GI wire making hole etc. as necy., mending good damages and painting as mentioned below a. on wall by clamp
Cable Glands & Socketing: Supplying and fixing compression type gland complete with brass gland, brass ring & rubber ring for dust & moisture-proof entry of XLPE/PVC armoured cables as below : a. 2 core 10 sqm
Finishing the end of following XLPE/PVC armoured cables by crimping method incl. supplying and fixing solderless socket (Dowels make), tapes, anticorrosive paste & jointing materials . a. 2 core 10 sqm
Distribution Wiring ; Supplying and Drawing 1.1 KV single core stranded 'FR' PVC insulated & unsheathed single core stranded copper wire (Make: R.R Kable / Polycab / Havells/Glostar/KEI) of the following sizes in the prelaid polythene pipe /PVC Conduit Pipe and by the prelaid GI fish wire and making necy. connection as required 2 X 1.5 sq.mm + 1 x 1.5 Sq.mm
Special Terms and Conditions 1. It is stated that the above work place is existing COVID Hospital, In case of any mishap or accidental to any staff that deputed by the agency the whole responsibility is to be borne by the concern agency. 2. The Agency shall be responsible for provisioning of all COVID safety measures including regular sanitiziation of work places, vaccination of employees and compliance of stated directive and COVID appropriate norms. 3. All the issues related to the safety of the staffs should be taken care by the agency itself. (Defect Libilities period for 01 year from the date of completion of work) (Rate should be quotated including all taxes and duties)
M/s Singh Electrical Works (BID ID -5629155)
Sanjay Shaw (BID ID -5624586)
MAA TARA ENTERPRISE (BID ID -5630869)
M/S ELECTRO POWER (BID ID -5631706)
ART CONSORTIUM (BID ID -5628666)
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .