Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.2 CrAccepted-AOC 104 INDIRA MARKET NEAR MALAI MANDIR SECTOR 07 RK PURAM NEW DELHI PIN 110022 | NEW DELHI | SOUTH WEST DELHI | DELHI | 110022 | ₹1.2 Cr | L1 | Accepted-AOC LOWEST BIDDER |
| 2 | L2₹1.7 Cr+₹44.2 L (35.4%)Rejected-Finance | ₹1.7 Cr+₹44.2 L (35.4%) | L2 | Rejected-Finance OTHER THAN LOWEST |
Tender Value
₹1.5 Cr
EMD Value
₹2.2 L
Closing Date
18 Feb 2023, 6:00 pmClosed
CWE NEW DELHI, DELHI CANTT
HQ CWE NEW DELHI, RAO TULA RAM MARG, DELHI CANTT 10
SPL REPAIR AND ADDN/ALTN TO ACCIDENT AND EMERGENCY DEPT AT AHRR UNDER GE (E/M) R AND R , DELHI CANTT-10
2022_MES_572437_1
CWE/ND-37/2022-23
Open Tender
Miscellaneous Works
Item Rate
150 days
DELHI CANTT
PLEASE REFER TENDER DOCUMENTS
9 documents required · 9 mandatory
₹1,000
GE E/M R AND R HOSPITAL
₹2.2 L
Yes
1 Apr 2023
31 Dec 2022
20 Feb 2023
31 Dec 2022
18 Feb 2023
4 Feb 2023
Amount
Dismantling of walls and ceiling boards or insulation board of any type board complete all as specified and directed.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises complete all as specified and directed.
Dismantling stone slab or tiles of any description or thickness in floors, aprons etc. laid bedded and pointed in any mortar complete all as specified and directed.
Taking down chowkhat or frames with shutter (without taking off shutter from frame) area n.exc 1.50 Sqm each and removal from site complete all as specified and directed..
Taking down chowkhat or frames with shutter (without taking off shutter from frame) area exc 1.50 Sqm but n.exc 4.00 Sqm each and removal from site complete all as specified and directed.
M & L for non-skid ceramic coloured tiles 7 to 8 mm thick area of each tile exceeding 0.11 Sqm but not exceeding 0.18 Sqm, in floors etc. over and including 15mm thick screed bed in cement mortar 1:6 set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tiles complete all as specified and directed..
M&L for glazed ceramic colour tiles in vertical surface of size 450 X 300 x 7 mm thick, set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tiles laid over and including 10mm thick rendering in cement mortar (1:4) complete all as specified and directed..
M&L for 18 to 20mm thick granite of any type (table rubbed & polished) in floors, jambs, pillars, window cills, platforms and like in cement mortar (1:4) including pointing in white cement (1:2) ,using marble dust with admixture of pigment to match with shade of granite, laid over and including 20mm thick screed bed in cement mortar 1:6 and cement slurry @3Kg/Sqm complete all as specified and directed.
M&L for coloured vitrified ceramic tiles 10mm thick double charged matt finish tiles (square/rectangular) area of each tile exceeding 0.42 Sqm but n. exc. 1.00 Sqm in floors etc. over and including 15 mm thick screed bed in cement mortar 1:6 , set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tiles complete all as specified and directed.
M&L for coloured vitrified ceramic tiles 10mm thick double charged tiles (square/rectangular) area of each tile not exceeding 0.36 Sqm in floors etc. over and including 15 mm thick screed bed in cement mortar 1:6, set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tiles complete all as specified and directed.
M&L for 40mm thick cement concrete 1:2:4, type B1 (using 20mm graded stone aggregate) as in sub-base finishing fair and even without using extra cement complete all as specified and directed.
Supply and fixing challenger antistatic, 2.0mm thick sandwiched type heterogeneous flooring in rolls form in width of 1.5mtr and continuous length of 20mtrs, surface electric resistance to be between 107 to 108 ohms including skirting in approved design and shade, including copper strips on periphery of the rolls as per manufacturer's instructions and connecting the copper strip at the end of the flooring to a bus bar connected to earth point and further sealing the joints by thermal welding process on a smooth and moisture free levelled floor surface using rubber based adhesive as recommended by manufacturer complete all as specified and directed. Note: - Design and shade shall be as approved by the GE.
S&F in repair ROLLER blinds vertical type 100% polyester (translucent) weight 230gm/Sqm made out of fabric cloth of approved shade fixed as per the instructions of manufacturers, complete all as specified and directed..
S&F PVC 18/19mm thick PVC moulded solid board, one side prelaminated for cabinets boxes, shutters , etc. with shelf and shutters full size fitted under/above kitchen cooking platform and other platform complete all as specified and directed.
M&L for 0.8mm thick stainless steel sheet (Gde 304) including stainless steel screws/fasteners, etc. fixed to any position horizontal or vertical surfaces including fabrication work for fixing of sheet complete all as specified and as directed.
S&F 12 mm thick block board as in wall cladding for fixing of SS sheet including required fixtures complete all as specified and as directed.
S&F 2nd class soft wood in scantling, framed , clean sawn for fixing block board in wall cladding complete all as specified and as directed.
Supply and fixing in repair aluminium composite panels cladding of approved make & shade having total thickness of 4 mm (Top coil -0.5mm , non Toxic PE - Core - 3 mm and back Coil -0.50 mm ) with 25 micron PVdF Coating on top coil and polyester / epoxy coating on back coil ( 4-7 microns ) on aluminium substructure fixed with 19 mm x 12 mm x 1.6 mm aluminium cleat & 10 x 100 mm SS Wooden screw with PVC plug on faced horizontal/ vertical surfaces of rectangular / circular columns ,suspended ceiling Cills , jambs ,canopy with including necessary aluminium frame ,scaffolding etc. and making 10 mm to 20 mm wide grooves and applying non staining and non sticking waterproofing silicon sealant of and backing rods complete all as specified and directed. Note :- (i) Only exposed surface shall be measured and paid for. (ii) ACP Material shall be for exterior application & shade as approved by Garrison Engineer
S&F 10 mm thick toughened tinted glass panels in vertical profile supported by existing glass mullions and held by existing spider fittings ,spring plates ,counter sunk bolts including all joints between the glass panels / glass mullions sealed by colour less structure silicon sealant complete all as specified and directed. .
S&F toughened glass frameless door with fixed portion, of 12 mm thickness, including cutting holes, edges rounded and etching works etc. and all kind of stainless steel patch fitting & fixture, spider patch etc., complete all as specified and directed. .
M&L sensor for operating toughened glass sliding door with complete fittings and sliding accessories complete all as specified and directed.
S&F toughened glass frameless window with fixed portion, of 12 mm thickness, area of window up to 4.00 Sqm in single piece glass including cutting holes, edges rounded and etching works etc. and all kind of stainless steel patch fitting & fixture, spider patch etc., complete all as specified and directed.
S&F of stainless steel handle 600 mm long fixed to 12 mm thick toughened glass door with and including all fixing accessories i. e. bolt washer, adhesive etc., complete all as specified and directed.
S&F of stainless steel door lock, glass to glass type, suitable for 12 mm thick frameless toughened glass door with and including all fixing accessories i. e. bolt, washer, screw, adhesive etc. of suitable size, complete all as specified and directed.
M & L for brick work with subclass ‘B’ bricks using old size bricks, straight or curved on plan exc 6m mean radius built in cement mortar 1:4 complete all as specified and directed.
M&L Brickwork with sub- class ‘B’ bricks using old size bricks, straight or curved on plan to any radius as in half brick thick walls built in cement mortar 1:4 complete all as specified and directed.
Taking down cement plaster on brick or stone walls, etc. including raking out joints, hacking for key, scrubbing down with water, etc. complete all as specified and directed.
M&L for rendering 15 mm thick in cement mortar (1:6) on fair faces of walls of brick work or concrete surfaces finished even and smooth without using extra cement complete all as specified and directed.
M&L for false ceiling at all heights with GRG (Glass Fiber Reinforced Gypsum) false ceiling tiles (fully perforated 10 mm thick square edged GRG false ceiling tiles) of Size 595x595 mm of approved texture, design and patterns having moisture content less than 2%, humidity resistance of 99%, NRC0.50 to 0.75 as per IS 8225:1987, Noncombustible as per BS 476 (part 4)-1970 and light reflectance of 85% (minimum) to be laid in true horizontal level suspended on inter-locking metal T-Grid of hot dipped galvanized iron section of 0.33mm thick (galvanized @ 120 grams per Sqm including both sides) comprising of main-T runners of size 15x32 mm of length 3000 mm, cross - T of size 15x32 mm of length 1200 mm and secondary intermediate cross-T of size 15x32 mm of length 600mm to form grid module of size 600 x 600 mm, suspended from ceiling using galvanized mild steel items (galvanizing @ 80 grams per Sqm) i.e. 50 mm long, 8 mm outer diameter M-6 dash fasteners, 6 mm dia fully threaded hanger rod up to 1000 mm length and L-shape level adjuster of size 85x25x2 mm. Galvanized iron perimeter wall angle of size 24x24x0.40 mm of length 3000 mm to be fixed on periphery wall / partition with the help of plastic rawl plugs at 450 mm center to center and 40 mm long dry wall wood screws. The work shall be carried out as per specifications, drawing complete all as specified and directed
M&L for 15mm thick screed plaster in cement mortar 1:4 mixed with Water Proofing Compound as per manufacturer's instructions, finished even and fair before application of water proof treatment complete all as specified and directed. Note :- Cost of Water Proofing Compound shall be included in Quoted rate for this item.
M&L for preparation of roof top surface of RCC slab by cleaning all the dust and loose material by wire brushing/blower/grinder including removal of vegetation/plantation from the roof surface and comprising of the following treatment: (a) M&L for preparation of roof top surfaces, providing and applying single component elastic cold applied polyurethane modified acrylic roofing system, co-elastic technology (CET) based on modified polyurethane and fully fiber reinforced, having sun reflectivity index (SR) of 109 on top of concrete roof surfaces. (b) M&L for treatment with crack seal of all cracks up to 3mm at corner joints, channel and parapets . (c) M&L for applying three coats including one coat of primer of ShaliUrethane BTD/Sikalastic 560/Smartcare damp proof ultra having coverage @ 0.75Kg/m² (min) and dilution up to 10% and laying reinforced fiber net and applying two coats of ShaliUrethane BTD/Sikalastic 560/Smartcare damp proof ultra @ total consumption 2Kg/m² in two coats for maintaining minimum dry film thickness 1.5mm and elongation at break of free film of approx. 350%. The material shall be applied with brush or roller, complete in all respect as per directions of Engr-in-Charge. Note:- 6hrs interval between two coats will be maintained. All auxiliary and accessories involved during application should be supplied by single manufacturer as a part of system. Make: STP / SIKA / ASIAN PAINT LTD or equivalent as approved by GE.
NOTES FOR ITEM NO. 31: - (i) Application of water proofing treatment shall be carried out by manufacturer or their Authorised Applicator only. (ii) 2.5% Amount of the total amount of water proofing treatment shall be retained as a guarantee and shall be released after 10 years. However, contractor may deposit the FDR of same amount in favour of GE. If contractor fails to rectify the defect pointed out during this period in writing, the defect shall be got rectified at contractor's risk and cost and the payment shall be made from the amount kept reserved or by encashment the FDR deposited by the contractor as the guarantee. The contractor's quoted rates for this item shall deemed to be inclusive of this aspect.
M & L for chipping of spalled and loose concrete and cleaning rust from reinforcement by sand blasting scrubbing down concrete surface with wire brushes cleaning with water allowed to dry and applying a layer of zinc rich epoxy primer as antirust on all exposed reinforcement followed by a layer of bonding coat of approved epoxy adhesive on complete exposed surfaces of concrete to be gunited all as specified and applying two layers of guniting over and including steel welded mesh having 2 mm dia of wire and aperture 50mm, total thickness of gunite n.exc 25mm thick (average thickness) in cement mortar 1: 2 using OPC 53 grade cement mixed with polycrete admixture @ 2% by weight of cement or as per manufacturers instructions and finally applying cement plaster over gunited surface of required thickness to give even uniform and smooth finish conforming to proper geometrics in cement mortar ( 1 : 3) to match with the existing surface as in sides and soffits etc. of slabs, chajjas, fins, facias, parapets, Lintels, columns and beams etc. complete including necessary scaffolding, shuttering, necessary chases to brick work or RCC members at any height upto 4 storey bldgs including finishes as existing complete all as specified & directed . Note:- Steel welded mesh is to be welded with the existing reinforcement . The cost of welded mesh deemed to be included in the quoted rates.
All as per item No. 32.00 above but thickness of gunite exc 25mm but n exc 40mm (avg thick)
Demolition of cement concrete (unreinforced) in ground floor and paving n.exc 15cm thickness (below or above ground level) and removing rubbish off bldgs. premises in a near by low lying area to a distance n.exc 500m etc., complete all as specified and directed.
M&L for broken bricks hardcore of gauge n exc. 63 mm, deposited, spread and levelled in layers n exc. 15 cm thick, watered and rammed to a true surface complete all as specified and directed
M&L for 75mm thick plain cement concrete 1:4:8 type D2 ( Using 40mm graded stone aggregate ) as in sub base complete all as specified and directed.
M&L for 25mm thick PCC 1:2:4 type B1 ( Using 20mm graded stone aggregate ) as in flooring complete all as specified and as directed.
S&F in repairs bib tap with flange cast copper alloy, chromium plated, screwed down to iron pipes or for brass ferrule of 15 mm bore complete all as specified and directed.
S&F in repairs angle valve with flange, cast copper alloy, chromium plated , screwed both ends for iron pipe of 15 mm bore complete all as specified and directed
S&F in repairs single lever basin mixture with 450mm long braided hoses, screwed down for iron pipe 15mm bore complete all as specified and directed.
S&F in repair two way angle valve with flange chromium plated for fixing to flushing cistern/jet spray/health faucet, etc. for iron pipe of 15 mm bore pipe complete all as specified and directed.
S&F in repair 1st quality vitreous China under counter wash basin, white, oval shape, size 560mmx430mmx195mm with fixing accessories excluding taps complete all as specified and directed.
S&F in repairs CP brass bottle trap heavy duty 32mm bore size with inlet and outlet screwed for pipe fixed to wash hand basin and connecting to waste pipe complete all as specified and directed.
S&F in repairs stainless steel towel rail 600mm long fixed with and including chromium plated brass screws and wooden/plastic cleats complete all as specified and directed.
S&F in repairs Chromium plated soap dish, fixed to plugs with chromium plated brass screws etc. complete all as specified and directed.
S&F in repair health faucet chromium plated with 1.00 meter tube long easy flexible tube in chrome finish and wall hook with NRV (back flow preventer) including necessary fittings as required for iron pipe of 15 mm bore pipe complete all as specified and directed.
S&F PVC connections 15mm size with PTMT nuts of length 450mm complete all as specified and directed.
S&F PVC valve less, syphonic action type of capacity 10 Litre flushing cistern low level white with inlet ball valve, float and handle including bracket and flush pipe to squatt pattern closet including all joints and making good to the floor complete all as specified and directed.
S&F Flush pipe of polyethylene of low or high density or PVC, 32 mm dia, for low level cistern complete all as specified and directed
S&F in repair 1st quality Vitreous China urinal flat back, size of 355mm x 340mm x 535 mm white with fixing accessories grating and union for discharge pipe (excluding flushing cistern, flush pipe and waste pipe) but including connections to flushing pipe and outgoing pipes complete all as specified and directed.
M&L for 1st quality vitreous china water closet Pedestal pattern white fixed in repairs including PP soft close seat cover, hinges, fixing accessories set of size 360mmx475mmx395mm fitted for P trap complete all as specified and directed.
S&F in repair Urinal spreader brass chromium plated for fixing with 15 mm dia pipe complete all as specified and directed.
S&F 4.8mm thick sheet glass ordinary quality and glazing with oil putty in square exc. 0.5 Sqm in each pane including hacking down from metal frame including punching or drilling out old glazing pins/spring clips and providing and fixing new ones complete all as specified and directed.
M&L for forming jambs, etc. in cement mortar 1:6 to openings (to foregoing item), including cutting, toothing and properly bonding into old work, also facing, jointing and pointing to match existing work, complete all as specified and directed.
M&L for preparation of newly plastered wall surfaces and applying two coats of distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gms/liter, of approved manufacturer, of required shade and colour complete, as per manufacturer's specification and by using Airless spray technology with max working pressure of 3300 PSI and capable of operating single spray gun with a maximum material hose length of 30mtrs the spray machine should be of reputed manufacturer and capability of tracking pressure and paint usage and certified by paint manufacturer and accessories for applying distemper in hard to reach areas and penetration of distemper on the surface complete all as specified and directed. Note: Sanding of surface to be done by mechanical sander with 1500 - 2700 RPM with internal dust extraction system for clean environment certified by paint manufacturer.
S&F 140mm floor door stopper of aluminium alloy body and tongue, anodised, with hard drawn steel spring, fixed in floor complete all as specified and directed.
Demolition of Brickwork or stone/boulder masonry, built in cement mortar including all quoins, arches, pillars, etc., but excluding ashlar facings, dressed stonework and precast concrete articles complete all as specified and directed
Taking up or down 15mm bore steel tubing and connections, including cleaning for refixing or removal from site complete all as specified and directed.
M&L for cutting existing steel tubing 15mm bore for alterations or additions (Each cut measured) complete all as specified and directed
S&F mild steel galvanised tubes, 'medium grade' 15mm bore with all fitting and fixed to walls and ceilings or laid in floors complete all as specified and directed.
Excavating in trenches, n.exc 1.5 m wide and n.exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n.exc 10 Sqm on plan and n.exc 1.5 m in depth and getting out in hard/dense soil complete all as specified and directed
M & L for cement concrete 1:4 8, type D-2, (using 40 mm graded stone aggregate) as in foundation mass concrete, complete all as specified and as directed.
Material & Labour for applying Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 Sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 Sqm over new surfaces complete all as specified and as directed.
S &F aluminium powder coated glazed three track sliding window of frame 100 x44x 1.5mm and sliding shutter of section 40mm x 19mm including 4 mm thick sheet glass, ordinary quality exceeding 0.5 Sqm in each pane in two track shutter an in one track stainless steel wire cloth, 0.40mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel and locking arrangements with each moving leaf complete all as specified and directed.
S&F aluminium powder coated chowkhat/frame of 100x44x1.5mm section with rebate complete including aluminium door shutter powder coated of extruded aluminium section, vertical style of door shutter of size 85mm x85 mm x 1.5 thick. Top, middle and bottom rail of size 85mmx 44.45 x 1.5mm thick including 4 mm thick plain sheet glass fixed with aluminium beading and rubber gasket/beading as directed including one mortice lock for each aluminium door and three nos aluminium hinges of size 100mm of and two aluminium tower bolts of 250mm size of each door fixed with rawl plug including making good floor/wall to match the existing surfaces complete all as specified and directed.
M & L for PCC 1 : 3 : 6, type C-2 (using 40mm graded stone aggregate)as in concrete bed to drain pipe including packing under and haunching against the all sides of pipe 450 mm bore complete all as specified and directed.
M & L for 450 mm bore reinforced concrete pipes, class NP2, laid and jointed complete with collars including making connections to existing lines complete all as specified and directed.
Returning, filling in, including spreading, leveling, watering and well ramming in layers not exceeding 25 cm thick, complete all as specified and directed.
Removal of excavated material not exceeding 50 mtrs and depositing where directed at a level not exceeding 1.5 metre above the starting point, complete all as specified and directed.
M&L in repair for factory made RCC manhole cover with cover frame comprising of 75 mm thick cover, area of each cover slab exc 0.5 Sqm & n exc 1.00 Sqm including provision of hot dip galvanized lifting hook for lifting overall cover with suitable size angle iron frame, RCC cover of M30 or higher grade concrete by vibro compression process, medium duty, confirming to IS-12592 including fixing on manhole, demolition of existing cover with cover frame and removal of debris from site complete all as specified and directed.
M&L for RCC (Nominal Mix) 1:2:4, type B-1 (using 20mm graded stone aggregate) as in slabs supported on walls, beams and columns in floors, canopies, deck slabs and in shelves and the like complete all as specified and directed.
M&L for RCC(Nominal Mix) 1:2:4 , type B-1 (using 20mm graded stone aggregate) as in beams, cantilevers, bressummers, lintels over 1.5m span complete all as specified and directed.
M&L for RCC(Nominal Mix) 1:2:4, type B-1 ( using 20mm graded stone aggregate) as in Chajjas complete all as specified and directed.
M&L for Mild steel TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed.
M&L for Mild steel TMT bars 5mm dia and over up to and including 10mm dia in stirrups, spacers and binders, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed.
M&L for use and waste of formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick (Horizontal or sloping) flat surface with rough finish complete all as specified and directed.
M&L for use and waste of formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including sup- ports, overhangs, etc. also splays between floors and beams, etc. with flat surface and rough finish complete all as specified and directed.
S&F 105X60mm pressed steel frames for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate, back filling with PCC 1:3:6 type C1, priming shop coat & two coats of synthetic enamel paint etc. complete all as specified and directed.
S&F factory made panelled shutters 35mm thick, 2nd class Hardwood, plain, framed, (any number of panels), with panels of timber flat on both sides (feather edged), or of veneered particle board medium density, wood particle board with commercial face veneers, fitted to chowkhat complete all as specified and directed.
S&F solid PVC door frames of size 50 mm X 47 mm, made out of 5 mm thick plain colour PVC sheets reinforced with MS square tubes complete all as specified and directed.
S&F for factory made solid PVC Moulded door shutter, 28 to 30mm thick (stile) with 2, 4 or 6 raised panel design with 2mm thick Moulded Prelam PVC sheet on the front face & 2mm plain colour PVC sheet on back face fixing in frame at site complete all as specified and directed.
S&F 250mm long aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast aluminium complete all as specified and directed.
S&F 100 mm size mild steel butt hinges medium weight cold rolled fixed/ welded to frame complete all as specified and directed.
S&F 200 mm long, aluminium, anodised, barrel tower bolts of extruded section complete all as specified and directed.
S&F 125mm size aluminium alloy handles, cast type, anodised complete all as specified and directed.
M&L for Cutting chases, pinning in, making good to facings where required and pointing in cement mortar 1:3 to ends to edges of landings, steps, cills, sunshade, shelves, lintels etc. and cutting chases for concealed water tubing etc. and making good, cutting n.exc 10 cm girth (brick wall) complete all as specified and directed.
S&F in repairs vitreous china 1st quality wash down water closet (EWC) white/ivory/off-white (excluding flushing cistern & flush pipe) complete, including connection to drain (or outgoing pipe) and to flushing pipe, anti-syphonage pipe, etc. complete all as specified and directed.
S&F health faucet (ABS body) mild steel chromium plated with 1.25 metre long flexible tube and ABS wall hook including making connections suitable for 15mm dia pipe and fixed in position complete all as specified and directed.
S&F bib tap cast copper alloy with crutch or butter fly handles, chromium plated, screwed down, screwed for iron pipe or brass ferrule and fixed of 15 mm bore pipe complete all as specified and directed.
S&F PVC waste pipe 32mm dia complete all as specified and directed.
S&F brass chromium plated, tubular towel rail, 20mm dia ,D type, 60 cm long between flanges complete all as specified and directed.
S&F stop/angles valves cast copper alloy, long Shank and cup (concealed type) fancy type chromium plated, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for union and fixed 15 mm bore complete all as specified and directed.
S&F soap dish brass chromium plated complete all as specified and directed.
S&F in repair of 4.0 mm thick figured glass, pin head type in squares n.exc 0.5 Sqm each panes as in aluminum window/Ventilator/door, including rubber packing and aluminium beading complete all as specified and directed.
S&F in repair of 4.00mm thick figured glass, pin head type in squares exc. 0.5 Sqm each panes as in aluminum window/Ventilator/door, including rubber packing and aluminium beading complete all as specified and directed.
S&F 1000 liters capacity rotational moulded polythene water storage tank, triple layer (cylindrical vertical with close top) hoisted and fixed in position including 20mm ball valve and dismantling of water tanks and all connection complete all as specified and directed.
S&F in repair 20mm ball valve high pressure of PTMT with epoxy coated Aluminium rod & high density plastic ball complete screwed for iron pipe and fixed for 20mm bore pipe complete all as specified and as directed.
S&F 20mm bore mild steel tubes, medium grade, galvanised, with all fitting and fixed to walls and ceilings or laid in floors complete all as specified and directed.
S&F Cast iron soil waste and vent pipe 100mm bore(sand cast type), in any length with or without ears, with cement joints and laid in trenches or in floor complete all as specified and directed.
S&F Cast iron soil waste and vent pipe 75 mm bore (sand cast type), in any length with or without ears, with cement joints and laid in trenches or floor complete all as specified and directed.
S&F Cast iron bends (any radius),100 mm bore, diminishing pieces or tapers (larger bore measured) complete all as specified and directed.
S&F Cast iron bends (any radius),75 mm bore, diminishing pieces or tapers (larger bore measured) complete all as specified and directed.
S&F Cast iron floor trap ,75 mm bore with grating, including jointing to waste pipe, fixed in cement concrete 1:2:4 type B1 complete all as specified and directed.
M&L for mild steel work as in Joist, channel, angle, or tee sections, fixed independently, without connecting plates, etc. (cut to ordinary lengths i.e. within 20mm of the length indicated) Fe 410-W (Gde E250) quality B complete all as specified and directed
S&F Pre- painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and directed.
M&L for preparation of new steel surfaces of any description over 10cm width or girth and applying 2 coat of synthetic enamel paint over and including a coat of red oxide primer complete all as specified and as directed.
M&L for preparation of new wooden surfaces of any description over 10cm width or girth and applying 2 coat of synthetic enamel paint over and including a coat of wooden primer complete all as specified and as directed.
Taking down carefully old unserviceable copper / aluminium point wiring with & including existing conduit/ batten type(light, fan, socket or power point) complete including fixture and fittings such as switches, ceiling rose, holder, regulators, sockets including making good the disturbed surfaces to match with the existing complete all as specified and as directed.
M&L for point wiring with 1.5 Sqmm nominal cross sectional area, single core, 1100 Volts grade, multi-stranded, PVC insulated, unsheathed FRLS copper conductor cable with and including continuous earth wire of size 1.5 Sqmm nominal cross sectional area, single core, 1100 Volts grade, multi-stranded, PVC insulated, unsheathed, FRLS copper conductor cable drawing into and including rigid non-metallic PVC conduit of 20mm dia or higher, medium grade complete with and including all PVC conduit accessories concealed into wall by cutting of chases in wall and replacement of modular metal flush box, modular white cover plate with frame, blanking plate etc. and making good to the disturbed surfaces to match the existing complete all as specified and directed for one light / bell point/fan/ /exhaust fan controlled by one, one way switch 06 Amps complete all as specified and as directed.
M&L for point wiring with 1.5 Sqmm nominal cross sectional area, single core, 1100 Volts grade, multi-stranded, PVC insulated, unsheathed FRLS copper conductor cable with and including continuous earth wire of size 1.5 Sqmm nominal cross sectional area, single core, 1100 Volts grade, multi-stranded, PVC insulated, unsheathed, FRLS copper conductor cable drawing into and including rigid non-metallic PVC conduit of 20mm dia or higher, medium grade complete with and including all PVC conduit accessories concealed into wall by cutting of chases in wall and replacement of modular metal flush box, modular white cover plate with frame, blanking plate etc. and making good to the disturbed surfaces to match the existing complete all as specified and directed for one 3 pin, 06 Amps socket outlet point on independent board controlled by one, one way 06 Amps switch complete all as specified and as directed.
M&L for point wiring with 1.5 Sqmm nominal cross sectional area, single core, 1100 Volts grade, multi-stranded, PVC insulated, unsheathed FRLS copper conductor cable with and including continuous earth wire of size 1.5 Sqmm nominal cross sectional area, single core, 1100 Volts grade, multi-stranded, PVC insulated, unsheathed, FRLS copper conductor cable drawing into and including rigid non-metallic PVC conduit of 20mm dia or higher, medium grade complete with and including all PVC conduit accessories concealed into wall by cutting of chases in wall and replacement of modular metal flush box, modular white cover plate with frame, blanking plate etc. and making good to the disturbed surfaces to match the existing complete all as specified and directed for one 3 pin, 06 Amps socket outlet point on same board controlled by one, one way 06 Amps switch complete all as specified and as directed.
M&L for point wiring with 2.5 Sqmm nominal cross sectional area, single core, 1100 Volts grade, multi-stranded, PVC insulated, unsheathed FRLS copper conductor cable with and including continuous earth wire of size 2.5 Sqmm nominal cross sectional area, single core, 1100 Volts grade, multi-stranded, PVC insulated, unsheathed, FRLS copper conductor cable drawing into and including rigid non-metallic PVC conduit of 20mm dia or higher, medium grade complete with and including all PVC conduit accessories concealed into wall by cutting of chases in wall and replacement of modular metal flush box, modular white cover plate with frame, blanking plate etc. and making good to the disturbed surfaces to match the existing for one 3 pin 15 Amps socket out let point controlled by one, one way switch on independent board complete all as specified and directed
M&L for point wiring with 4 Sqmm nominal cross sectional area, single core, 1100 Volts grade, multi-stranded, PVC insulated, unsheathed FRLS copper conductor cable with and including continuous earth wire of size 4 Sqmm nominal cross sectional area, single core, 1100 Volts grade, multi-stranded, PVC insulated, unsheathed, FRLS copper conductor cable drawing into and including rigid non-metallic PVC conduit of 20mm dia or higher, medium grade complete with and including all PVC conduit accessories concealed into wall by cutting of chases in wall and replacement of modular metal flush box, modular white cover plate with frame, blanking plate etc. and making good to the disturbed surfaces to match the existing for industrial socket outlet for AC/Geyser 3 pin 16 / 20 Amps point complete all as specified and directed
S&F modular switch, 06 Amps, single pole, one way, 250 volts, one module and IP 20 protection complete all as specified & directed
S&F modular switch with indicator, 16 Amps, single pole, one way, 250 volts, one module IP 20 protection complete all as specified & directed
S&F modular socket outlet 05 Pin, 06 Amps, 02 module with shutter complete all as specified & directed
S&F modular socket outlet 02 in 01, 03 pin, 06 Amps and 16 Amps, 02 module with shutter complete all as specified & directed
S&F ceiling fan regulator, stepped type of 0 to 04 rotary steps, electronic, 02 module, hum free, AC, 230 volts, 100 watts, duly ISI marked complete all as directed.
S&F ceiling rose, 6 Amps, 250 volts, AC with three terminals and PVC / Polycarbonate insulated body of 50 x 25mm size complete all as directed.
Taking down light fittings of any type complete all as specified and directed.
S&F LED tube light fitting 20 watt (CW), 4 feet long in extruded aluminium batten with high efficient LEDs available in milky diffuser, PF>0.95 and Voltage rated 220V to 240V complete all as specified and directed.
S&F LED tube light fitting 10 watt (CW), 2 feet long in extruded aluminium batten with high efficient LEDs available in clear & milky diffuser, PF>0.95 and Voltage rated 220V to 240V complete all as specified and directed.
S&F surface/ ceiling mounted LED panel type of size 2ft x 2ft, 36W, 230V, 5700K complete with driver having precisely designed decorative PMMA diffuser LED panel with CRCA powder coated white housing complete with all accessories required for connection and making good the disturbed ceiling complete all as directed.
S&F recess/surface mounted LED light fitting 12 watt slim round down lighter with high efficient LEDs and glare free opal diffuser including fixing accessories complete all as specified and as directed.
Refixing LED Panel of size 2ft x 2ft with all connected accessories complete all as specified and as directed.
Taking down carefully ceiling fan/Exhaust Fan/cabin fan of any size, sealing cable end, dismantling blades & removing fan and blades to store complete all as specified and as directed.
M&L for painting of ceiling fan complete with synthetic enamel paint by spraying including filling cavities with filter one coat after cleaning complete all as specified and as directed.
Hanging only with fixing accessories ceiling fan and connecting with and including 3 core flexible copper cable from ceiling rose to fan complete all as specified and as directed.
Fixing only exhaust fan/cabin fan and connecting up including provision of cable from ceiling rose to connector block complete all as specified and as directed.
M&L for Sub main wiring with 6 Sqmm (Nominal area) with two runs of single core cable PVC insulated FRLS multistranded unsheathed copper conductor cable including 1100 V grade, drawn into & including concealed PVC rigid Conduit & all PVC conduit accessories including cutting chases & making good to walls including 6 Sqmm (nominal area) single core PVC insulated multistranded unsheathed copper conductor as earth wire and duly connected to all common earth point complete all as specified and as directed. Note :- Two run of 6 Sqmm wire, one run of 6 Sqmm wire for earth wire and PVC conduit will be measured as one unit .
M&L in replacement Sub main wiring with 10 Sqmm (Nominal area) with two runs of single core cable PVC insulated FRLS multistranded unsheathed copper conductor cable including 1100 V grade, drawn into & including concealed PVC rigid Conduit & all PVC conduit accessories including cutting chases & making good to walls including 10 Sqmm (nominal area) single core PVC insulated multistranded unsheathed copper conductor as earth wire and duly connected to all common earth point complete all as specified and as directed. Note :- Two run of Sqmm wire, one run of 10 Sqmm wire for earth wire and PVC conduit pipe will be measured as one unit
M&L in replacement Sub main wiring with 6 Sqmm (Nominal area) with two runs of single core cable PVC insulated FRLS multistranded unsheathed copper conductor cable including 1100 V grade, drawn into & including concealed PVC rigid Conduit & all PVC conduit accessories including cutting chases & making good to walls including 6 Sqmm (nominal area) single core PVC insulated multistranded unsheathed copper conductor as earth wire and duly connected to all common earth point complete all as specified and as directed. Note :- Two run of 6Sqmm wire, one run of 6 Sqmm wire for earth wire and PVC conduit pipe will be measured as one unit.
M&L in replacement Sub main wiring concealed with 04 Sqmm (Nominal area) with two runs of single core cable PVC insulated FRLS multistranded unsheathed copper conductor cable including 1100 V grade, drawn into & including concealed PVC rigid Conduit & all PVC conduit accessories including cutting chases & making good to walls including 4 Sqmm (nominal area) single core PVC insulated multistranded unsheathed copper conductor as earth wire and duly connected to all common earth point complete all as specified and as directed. Note :- Two run of 4Sqmm wire, one run of 4 Sqmm wire for earth wire and PVC conduit pipe will be measured as one unit.
M&L in replacement Sub main wiring with 16 Sqmm (Nominal area) with four runs of single core cable PVC insulated FRLS multistranded unsheathed copper conductor cable including 1100 V grade, drawn into & including concealed PVC rigid Conduit & all PVC conduit accessories of suitable size including cutting chases & making good to walls including 16 Sqmm (nominal area) single core PVC insulated multistranded unsheathed copper conductor as earth wire and duly connected to all common earth point complete all as specified and as directed. Note :- Four run of 16 Sqmm wire, one run of 16 Sqmm wire for earth wire and PVC conduit pipe will be measured as one unit.
Taking down DBs of any size complete all as specified and directed.
S&F sheet metal enclosure distribution board, single pole and neutral, AC, 240 volts, with 200 Amps rated copper bus bar and metal door with IP - 43 & IK 09 protection along with cable end box for DB and flush to wall including all cutting etc. in wall and making good to the disturbed surfaces to match the existing complete all as specified and as directed for following No of way :-
S&F sheet metal enclosure distribution board triple pole and neutral (TPN), AC, 440 volts of following ways with 200 Amps rated copper bus bar and metal door with IP 43 & IK 09 protection along with cable end box for DB and flush to wall including all cutting etc. in wall and making good to the disturbed surfaces to match the existing complete all as specified and directed :-
S&F sheet metal enclosure distribution board triple pole and neutral (VTPN), AC, 440 volts of following ways with 200 Amps rated copper bus bar and metal door with IP 43 & IK 09 protection along with cable end box for DB and flush to wall including all cutting etc. in wall and making good to the disturbed surfaces to match the existing complete all as specified and directed :-
S&F in repair MCB SPN, AC, 240 volts of 63 Amps capacity, 10 KA breaking capacity and making connections by using suitable copper lugs complete all as specified and as directed.
S&F in repair MCB, SP, AC, 240 volts of 6 to 32 Amps capacity, 10 KA breaking capacity and making connections by using suitable copper lugs complete all as specified & directed.
S&F in repair MCCB 4 pole, 415 Volt adjustable type of following capacity Complete all as specified and directed.
200 Amp, 36 KA breaking capacity
160 Amp, 36 KA breaking capacity
Supply and fixing in repair 415V 10KA 'C' curve miniature circuit breaker (MCB) of 40 to 100 Amps TPN in the DB complete with connection & testing complete all as specified and directed. .
Taking down water heater storage type of any capacity carefully & kept in safe custody of contractor and refixing complete with all accessories complete all as specified and directed.
Supply and fix in replacement comfort bed head light fitting in extruded aluminium housing with PMMA diffuser having personalised bidirectional up & down light for pleasant and smoothing light experience including 03 Nos switches for each light complete all as specified and directed.
Supply and fix in replacement LED Sign board of size 96"x24"made out of ACP sheet fixed in stainless steel frame of suitable depth including writing any type acrylic letters of size 10" including provision of LED with necessary wiring from back side complete all as specified and directed.
Taking down the old cable of 70 Sqmm size carefully from trenches, walls and surfaces complete all as specified and as directed.
M&L for Sand filling in and around LT/HT cable 8cm thick below and 15cm above the cable respectively after laying the cable gently punning down complete all as specified and directed. Note:- Only Punned thickness will be measured & paid.
M&L for laying of bricks of common burnt clay, sub class-B for LT underground cable protection, complete all as specified and as directed.
Supply, laying and testing 400.00 Sqmm 3.5 core cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor laid in trenches/ at walls/ over roof etc. with proper clamp and other fixing accessories complete all as specified & directed.
Supply, laying and testing 70.00 Sqmm 3.5 core cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor laid in trenches/ at walls/ over roof etc. with proper clamp and other fixing accessories complete all as specified & directed.
Dismantling of old existing panel complete all as specified and as directed.
Supply, Install , testing and commissioning of powder coated LT panel of size not less than 120cm x 120cm x 30cm for 3 Phase 415 Volts outdoor type cubical compartmentalised vermin and water proof fabricated out of 3.15 mm thick CRCA sheet powder coated front and back door openable suitable for and including 400 amps rated Aluminium bus bar, insulated with PVC sleeves and coloured with (red, yellow, blue and black) CTR and internal wiring with suitable size of PVC insulated copper wire, use with angle iron 50x50x6 mm frame bottom of the panel board , grouted by using PCC foundation 1 : 2 : 4 type B1 with 20 mm graded stone aggregate , thimbling and cable entry boxes with cable gland complete with suitable for housing & including the following :-
INCOMING :- (a) MCCB 4 pole, 415 volts 400 amps 36 KA, Adjustable type - 02 Nos. (b) Onload Change over switch of capacity 400 Amps - 01 No. OUTGOING :- (a) MCCB 4 pole, 415 volts 100 amps of 25 KA - 03 Nos . (b) MCCB 4 pole, 415 volts 63 amps of 16 KA - 03 Nos . (c ) On load change over switch of capacity 400 Amps. (d) Ammeter Digital programmable type suitable for 400 Amp - 01 No. (e) Volt meter digital programmable type suitable for 415 volts - 01 No. (f) LED Indicator lamp RYB (set of 3) - 01 Set
Supply & fix wireless multiservice for three service call ( Nurse Calling, House Keeping and Code Blue) Bed unit and reset with Optional wireless door indicator, with built-in RFAF, environment condition, operating temp 0 degree centigrade-50 degree centigrade( 32 degree F - 122 degree F) operating voltage humidity 10%-90% without congealment power requirement, operating voltage 12 Voltage battery operating current -standby< 10 mA, working status < 10 mA packing contents wireless bed unit button with handset DC 12V battery screws and mounting plate including fixing accessories, complete all as specified and directed.
Supply & fix wireless display unit with human voice address and built-in RFAF frequency attention filter , having the following specification complete all as specified & directed :- (i) Capacity : Max 50 beds, 7 seg LED display max, 2 digit for one bed receiving 3 LED indicators ( Nurse Calling, House Keeping and Code Blue), (ii) Power requirement : AC 230 V, 5Amps, 50 Hz (iii) Operating Temp : 0 to 50 °C ( 32°F - 122°F) (iv) Operating Humidity: 10%-90% without congealment (v) Operating Voltage : 05 volt DC-12 volt DC (vi) Operating current : 200mA, Standby<30mA, Full load<35mA (vii) Startup current : 600 mA (viii) Speaker : Full duplex (ix) Impedance : 8Ώ ± 15% (x) Max output Power : 0.5 W (xi) Distribution Rate : 5% Max (xii) Max dB : 89 ± 3dB (xiii) Frequency Range : 433 KHz
Supply, installation testing & commissioning of the sky light of size 6ft x 4ft of following design or nature as required printed on antibacterial material fixed at false ceiling complete all as specified & directed :- MOC: Printed ceiling fabric, Lightweight PVC Membrane Fabric sheet Thickness: 0.2 mm Light source: LED with controller Type: Non-flammable Fitment: Ultrasonically welded Edge, Harpoon Fit Security fit in the track Track: Aluminium
Supply, install, testing and commissioning a complete set of ceiling suspended beam system with at least 1.8 metre extruded Aluminium profiles and two vertical pendants performing the support functions, two separate compartments shall be provided for electricity and medical gas supplies, including suspension tube, End cover set and Beam profile, with left & right vertical service columns complete all as specified and as directed including the following accessories/parts: (a) Beam Profile: at least 1800 mm Beam profile (b) Lighting 1 x Indirect light & 1x Direct light (c) Left side vertical Column (i) Service head including slider (ii) Lighting control (iii) Light switch g.RJ45 socket (iv) Provision for nurse call socket (cut out only) (v) 3 UPS power socket (vi) 3 IPS power socket (vii) Medical oxygen outlet- 1 No. (viii) Air 4 outlet - 1 No. (ix) Vacuum outlet - 1 No. (x) Accessories: (xi) IV pole 4 Hooks (d) Right side vertical column (i) Service head including slider (ii) RJ45 socket (iii) 3 UPS power socket
Supply, Installation, Testing and Commissioning of Two Plate dimmable X-Ray viewing screen designed to provide a high level of control luminance without flicker. The dimming range will be from 3-100% . The X-ray will have inbuilt sensor for X-ray film . On/Off and dimming operation will be through integrated PCB. TWO PLATE X-RAY will be CE certified and in compliance under Class 1 Medical devices complete all as specified and directed.
S&F ceiling fan panel type of size 2ft x 2ft ready to fix in the ceiling with all fixing arrangements & accessories complete all as specified and directed.
M&L for MS ERW pipe 80 mm bore 'C' Class with all fitting i.e. including tee, elbow, reducer, union, nipple, socket etc., as in floors, walls, ceiling including hangers for sprinklers piping, jointing by welding, aligning the pipe line, painting with a red oxide primer coat and two coats of synthetic enamel paint fire red colour, providing tapping for pressure gauges and for other instruments etc. and also including. Hydraulic testing of system, flushing and cleaning by water etc. complete all as specified & directed.
M&L for MS ERW pipe 50 mm bore C Class with all fitting i.e. including tee, elbow, reducer, union, nipple, socket etc., floors, walls, ceiling including hangers for sprinklers piping, jointing by welding, aligning the pipe line, painting with a red oxide primer coat and two coats of synthetic enamel paint fire red colour, providing tapping for pressure gauges and for other instruments etc. and also including. Hydraulic testing of system, flushing and cleaning by water etc. complete all as specified & directed.
M&L for MS ERW pipe 25 mm bore C Class with all fitting i.e. including tee, elbow, reducer, union, nipple, socket etc., floors, walls, ceiling including hangers for sprinklers piping, jointing by welding, aligning the pipe line, painting with a red oxide primer coat and two coats of synthetic enamel paint fire red colour, providing tapping for pressure gauges and for other instruments etc. and also including. Hydraulic testing of system, flushing and cleaning by water etc. complete all as specified & directed. Note for srl Item No 159 to 161 : Dismantling and refixing of ceiling and paneling and making holes through walls / shaft or ground for passing pipes including MS flat iron supports, nuts , bolts etc. are deemed to be included in quoted rate.
M&L for CI Sluice valve of 80 mm PN 1.6 as per IS;14846 including CI flange with gasket, nuts, bolts, washers complete all as specified and as directed.
S&F gun metal gate/ball valve of 50 mm bore dia ISI marked to IS:778-1984 Class-I screwed in bonnet, non rising stem screwed ferrule ends as per IS-554 complete all as specified and as directed.
S&F gun metal gate valve of 25 mm bore dia ISI marked to IS:778-1984 Class-I screwed in bonnet, non rising stem screwed ferrule ends as per IS-554 complete all as specified and as directed.
S&F Sprinkler glass bulb type (Standard response) as per IS:15106/TAC guidelines 68 degree temperature rating pendent type including rosette complete all as specified and as directed.
S&F Sprinkler Upright type (Standard response) as per IS:15106/TAC guidelines 68 degree temperature rating pendent type including rosette complete all as specified and as directed.
Supply, fixing, install and testing self priming booster pump set couple set three phase, 415 V, 45 metre head, brass impeller, stainless steel shaft, 450 to 480 LPM, 2900 RPM, copper winding, , nuts, bolts for connection to main panel, including welding, threading, nuts, bolts, foundation of pump (PCC 1:2:4), making housing with locking arrangement and including automatic starter in Stainless Steel Enclosure with pressure switch with complete wiring connect with motor pump for auto operation of the panel and pressure gauge complete all as specified and as directed.
M&L in replacement Sub main wiring with 10 Sqmm (Nominal area) with four runs of single core cable PVC insulated FRLS multistranded unsheathed copper conductor cable including 1100 V grade, drawn into & including surface steel Conduit & all conduit accessories of suitable size including 10 Sqmm (nominal area) single core PVC insulated multistranded unsheathed copper conductor as earth wire and duly connected to all common earth point complete all as specified and as directed. Note :- Four run of 10 Sqmm wire, one run of 10 Sqmm wire for earth wire and steel conduit pipe will be measured as one unit.
Dismantling of existing copper pipeline and S& F testing and commissioning BSI Kite Mark copper tube of size 12 mm Nominal outer diameter , min 0.70 mm wall thickness suitable for medical gas pipe line, seamless, deoxidized, non-arsenical, half-hard and conforming to BS : EN :13348 : 2016 and manufactured as per BS-2871 including saddles and all connected items complete all as specified and as directed.
Dismantling of existing copper pipeline and S& F testing and commissioning BSI Kite Mark copper tube of size 15 mm Nominal outer diameter , min 0.70 mm wall thickness suitable for medical gas pipe line, seamless, deoxidized, non-arsenical, half-hard and conforming to BS : EN :13348 : 2016 and manufactured as per BS-2871 including saddles and all connected items complete all as specified and directed.
Dismantling of existing copper pipeline and S & F testing and commissioning BSI Kite Mark copper tube of size 22 mm Nominal outer diameter , min 1.0 mm wall thickness suitable for medical gas pipe line, seamless, deoxidized, non-arsenical, half-hard and conforming to BS : EN :13348 : 2016 and manufactured as per BS-2871 including saddles and all connected items complete all as specified and directed.
Dismantling of existing flow meter & Supply and installation of BPC single type pipe line flow meter WITHOUT BOTTLE complete all as specified and directed.
Supply and installed in replacement of humidifier bottle (18-04-57) including pressure gauge, flow adjuster, screw cap, pressure reducing valve, safety valve complete testing and commissioning complete all as specified and directed.
Supply and fix in replacement Vacuum Jar (18-04-57) capacity 600 ML including connected items complete all as specified and directed.
Supply and fix in replacement Vacuum regulator as desire complete all as specified and directed.
Supply and fix in replacement Air regulator as desire complete all as specified and directed
S& F in replacement Gas outlet point BS type including Prob for Oxygen, Vacuum/air complete all as specified and directed.
S & F in replacement low pressure tubing medical grade complete all as specified and directed.
M & L for cutting existing Oxygen/Air and Vacuum gas pipe line placing the control valve as per the requirement and making leakage free gas pipe line complete all as specified and directed. Note- Valve of any description should be measured separately
Dismantling of existing valves & Supply and installed ,testing and commissioning isolation valve for medical gas service of following size , CE marked and manufactured as per ISO -13458 complete all as specified and directed. Make-RBI/Medline/Modular Health care system(MHS)/RN
Valve size 12 mm
Valve size 15 mm
Valve size 22 mm
Supply, installation, testing and commissioning for Oxygen, vacuum and Air alarm system digital type display CE marked, HTM 02-01 or NFPA-99 Standards, with working voltage 230 volts, single phase, 50 Hz, including copper pipe connection with main pipe and electric connection, as in replacement comprising with following parameter complete all as specified and directed. (a) Oxygen low red LED 0 to 45 Psi/Low caution yellow LED 45 to 50/High caution yellow LED 65 to 70, Normal Green LED 50 to 65, high indication Red light <75. (b) Air low Red LED 0 to 45 Psi/Low caution yellow LED 45 to 50/High caution yellow LED 65 to 70, Normal Green LED 50 to 65, high indication Red light <75.
Supply Installation, Testing & Commissioning of area valve service units for 3 service. It should meet with the requirements of the HTM 02-01 or NFPA 99, CE certified, UL listed, adopter having opening by quarter turn of handle. The valve should be pneumatically tested as per BSEN 1057 for twice the working pressure and degreased for medical gas service . Valve box should be equipped with components for shutting off and allowing supervision by Hospital staff & should allow the ward staff to isolate the areas for maintenance and repair work. The pressure monitoring of the distribution system is done by pressure gauges. In case of emergency the door can be glass break opened or by unlocking using the key complete all as specified and directed.
S&F 2 metre wired handset for three service calling, reset facility and optional door indicator complete all as specified and directed.
M/s KUMAR BUILDERS
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .