Loading…
Loading…
| # | Company | Status |
|---|---|---|
| 1 | Accepted-Technical 0 MATADIN KAKRAHI KAKRAHI BHARTHANA ETAWA ETAWAH UTTAR PRADESH 206242 | ETAWAH | UTTAR PRADESH | 206242 | Accepted-Technical Accepted |
| 2 | Accepted-Technical M S ASHAPURI INFRACON PVT LTD VILLAGE AND PO HURLA TEHSIL BHUNTER DISTT KULLU H P | Accepted-Technical Accepted |
| 3 | Accepted-Technical NOT AVAILABLE | FARIDABAD | HARYANA | 121004 | Accepted-Technical Accepted |
| 4 | Rejected-Technical | Rejected-Technical Rejected |
Tender Value
₹4.6 L
EMD Value
₹9,250
Closing Date
5 May 2026, 10:30 amClosed
Executive Engineer
HP City Transport and Bus Stand Management And Development Authority Tutikandi Shimla -4
SH Replacement of damaged E.I work i.e. Main panel, busbar,LED battens,LED street lights etc
2026_BSMDA_134225_8
No.HPBSMDA/EE/(2)2025-2026 Tender Vol-V
Open Tender
Electrical Works
Item Rate
60 days
Jubbal
Please refer tender document
9 documents required · 9 mandatory
₹415
HPBSMDA
₹9,250
6 Jun 2026
13 Apr 2026
5 May 2026
14 Apr 2026
5 May 2026
14 Apr 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1.01 | Wiring for light point / fan point / exhaust fan / call bell point with 1.5 Sq. mm. PVC insulated heat resistant flame retardant (HRFR) and low smoke single core (flexible) copper conductor cable in surface/recessed PVC conduit and earthing the light point with 1.5 Sq.mm. HRFRLS/PVC insulated single core copper conductor cable as required.. Group C | - | Each | - | - |
| 2.01 | Wiring for circuit/sub-main with following size PVC insulated heat resistant flame retardant (HRFR) and low smoke single core (flexible) copper conductor cable in surface/recessed PVC conduit along with 1 No. HRFRLS/PVC insulated single core copper conductor cable of same size for earthing as required.2x1.5 Sq. mm. | - | Per Meter | - | - |
| 3.01 | Wiring for circuit/sub-main with following size PVC insulated heat resistant flame retardant (HRFR) and low smoke single core (flexible) copper conductor cable in surface/recessed PVC conduit along with 1 No. HRFRLS/PVC insulated single core copper conductor cable of same size for earthing as required.2x2.5 Sq. mm. | - | Per Meter | - | - |
| 4.01 | Wiring for circuit/sub-main with following size PVC insulated heat resistant flame retardant (HRFR) and low smoke single core (flexible) copper conductor cable in surface/recessed PVC conduit along with 1 No. HRFRLS/PVC insulated single core copper conductor cable of same size for earthing as required.2x4.0 Sq. mm. | - | Per Meter | - | - |
| 5.01 | Wiring for circuit/sub-main with following size PVC insulated heat resistant flame retardant (HRFR) and low smoke single core (flexible) copper conductor cable in surface/recessed PVC conduit along with 1 No. HRFRLS/PVC insulated single core copper conductor cable of same size for earthing as required. 2 x 6 Sq. mm. | - | Per Meter | - | - |
| 6.01 | Wiring for circuit / sub-main with 4x16 Sq. mm. PVC insulated heat resistant flame retardant (HRFR) and low smoke single core (flexible) copper conductor cable in surface/recessed PVC conduit along with 2 No.16 Sq.mm. (4x16+2x16) HRFRLS/PVC insulated single core copper conductor cable for earthing as required. | - | Per Meter | - | - |
| 7.01 | Re-wiring for light point / fan point / exhaust fan / call bell point with 1.5 Sq. mm. PVC insulated heat resistant flame retardant (HRFR) and low smoke single core (flexible) copper conductor cable in existing surface/recessed Steel / PVC conduit and earthing the light point with 1.5 Sq.mm. HRFRLS/PVC insulated single core copper conductor cable including dismantling of the existing wiring as required. ( including switch & bakelite sheet etc.) Group C. | - | Each | - | - |
| 8.01 | Supplying and drawing following size of PVC insulated, heat resistant, flame retardant (HRFR) and low smoke single core (flexible) copper conductor cable in existing surface /recessed, Steel/PVC conduit as required. PVC insulated HRFR LS Copper conductor 1.5 Sq. mm. 3x1.5 Sq. mm. | - | Per Meter | - | - |
| 9.01 | Supplying and drawing following size of PVC insulated, heat resistant, flame retardant (HRFR) and low smoke single core (flexible) copper conductor cable in existing surface /recessed, Steel/PVC conduit as required. PVC insulated HRFR LS Copper conductor 4 Sq. mm. 3x4.0 Sq. mm. | - | Per Meter | - | - |
| 10.01 | Supplying and drawing following size of PVC insulated, heat resistant, flame retardant (HRFR) and low smoke single core (flexible) copper conductor cable in existing surface /recessed, Steel/PVC conduit as required. PVC insulated HRFR LS Copper conductor 4 Sq. mm. 5x4.0 Sq. mm. | - | Per Meter | - | - |
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.87 MB
SBD9.pdf
Tender Documents • 10.52 MB
BOQ_198507.xls
BOQ • 0.30 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .