| 1 | L1₹41.2 LAccepted-AOC | L1 | Accepted-AOC BEING L1 BIDDER | |
| 2 | L2₹42.5 L+₹1.2 L (3.01%)Rejected-Finance OLD HASIMARA PO HASIMARA DISTT ALIIPURDUAR WB PIN 735215 | HASIMARA | ALIPURDUAR | WEST BENGAL | 735215 | L2 | Rejected-Finance Other than L1 | |
| 3 | L3₹43.4 L+₹2.2 L (5.32%)Rejected-Finance 21 JHAMRI 151 JHAMRI JHAMRI ROHTAK HARYANA 124142 UDYAM HR 07 0030314 | JHAJJAR | HARYANA | 124142 | L3 | Rejected-Finance Other than L1 | |
| 4 | L4₹44.4 L+₹3.2 L (7.67%)Rejected-Finance | L4 | Rejected-Finance Other than L1 | |
| 5 | L5₹45.1 L+₹3.9 L (9.41%)Rejected-Finance | L5 | Rejected-Finance Other than L1 |
Tender Value
₹43 L
EMD Value
₹86,000
Closing Date
12 Jun 2024, 6:00 pmClosed
GE (AF) HASIMARA
GE (AF) HASIMARA PO-HASIMARA DIST- ALIPURDUAR PIN-735215
REPAIR/MAINT INCLUDING CCD PAINTING OF VARIOUS OFFICE AND OTHER BUILDINGS IN TECH AREA, REPAIR/ MAINT OF ELECTRIC FANS AN CONNECTED WORKS, REPAIR/MAINT OF GEYSERS AND CONNECTED ITEMS AND REPAIR/MAINT OF OUTDOOR BUILDING SECURITY LIGHTS AND CONNECT
2024_MES_654862_1
C/8754/2024-25/E8
Open Tender
Civil Works
Item Rate
210 days
GE (AF) HASIMARA
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE (AF) HASIMARA
₹86,000
Yes
24 Jul 2024
18 May 2024
19 Jun 2024
18 May 2024
12 Jun 2024
5 Jun 2024
Amount
Taking down cement plaster any description on brick or stone walls, etc. including raking out joints, hacking for key, scrubbing down with water etc, complete all as specified and dircted.
M&L 15mm thick rendering in CM (1:6) on other than fair faces of brick work or concrete surfaces of wall, finished even and smooth without using extra cement, complete all as specified and directed.
M & L for rendering 15mm thick (10mm + 5mm) in two coats on fair faces of brick work or concrete surfaces of wall in CM (1:4), mixed with integral water proofing compound at top layer as per manufacturer's instructions and finished the surface even and fair without using extra cement, complete all as specified and directed. (Note : WPC shall be measured and paid separately against respective item as supply only.)
Supply only liquid water proofing compound conforming to IS: 2645 - 1975 specification, complete all as directed
M&L 5mm thick rendering in CM (1:3) on fair faces of brick work or concrete surfaces, finished even and smooth (without using cement), as on ceiling, complete all as specified and as directed.
M&L for prepration of newly plastered wall surfaces and applying two coats of acrylic distemper a coat of on primer over and including a coat of 2mm thick wall care putty to prepare the surface even and smooth, complete all as specified and directed.
M&L for preparation of newly plastered ceiling surfaces and applying three coat of white wash, complete all as specified and directed.
M&L for preparation new plastered surfaces of wall and applying two coats of 100% premium acrylic exterior emulsion paint alkali & fungal resistance of required shade including primming coat of exterior emulsion primer as per manufacturer's instructions, complete all as specified and directed.
M&L for prepration of old surface of wall and applying one coat of acrylic distemper on primer surface over a coat 1mm thick of wall care putty prepare the surface even and smooth surfaces, complete all as specified and directed.
M & L for preparation of old plastered ceiling surfaces and applying two coats of white wash, complete all as specified and directed.
M&L for preparation old plastered surfaces of wall and applying one coat of 100% premium acrylic exterior emulsion paint alkali & fungal resistance of required shade as per manufacturer's instructions, complete all as specified and directed.
M&L for writing letters or figures (Block. Roman, Italic or Indian) n. exc. 30cm high, complete all as specified and directed.
M&L for preparing old wooden surfaces of any description, not otherwise described over 10cm width or girth and applying one coat of synthetic enamel paint (1st grade quality), complete all as specified and directed.
M&L for preparing old steel/iron surfaces of any description, not otherwise described over 10cm width or girth and applying one coat of synthetic enamel paint (1st grade quality), complete all as specified and directed.
Taking down carefully ceiling fans/exhaust fans from any height and of any make and sweep including disconnecting the cable from ceiling rose and deposited to MES store for repair/replacement and refixing the same, complete all as specified and directed. Note : Replacement of spare parts, rewinding, painting, cable for connection etc to be measured and paid separately under relevant items.
S&F in repair of switch piano flush button 5 Amp single pole one way 230 volts white finish, complete all as specified and directed.
M&L for replacement and connecting up fan regulator electronic on existing phenolic laminated sheet dimmer type 230 volts, 450 watts suitable for ceiling fan 1200/1400mm sweep, complete all as specified and directed.
S&F in repair modular type fan regulator, AC 230 Volts, complete all as specified and directed.
M & L for preparation of painted surfaces of ceiling fan of any make and size up to 1400mm sweep and applying one coat of synthetic enamel white paint (1st grade quality) by spray painting including marking of MES No on bottom of fan by applying black paint, complete all as specified and directed.
M & L for preparation of painted surfaces of exhaust fan by gray paint for exhaust fans of any make and size up to 300/450mm sweep and applying one coat of synthetic enamel white paint (1st grade quality) by spray painting including marking of MES No by applying black paint, complete all as specified and directed.
M & L for replacement of short circuit /over heated winding from stator of ceiling fan of any make having 1200mm sweep with matching gauge and turns of super enamelled copper winding wire complete with leathered paper, glass sleeves, varnishing, baking, heating, drying, cleaning fan bearing/bushes, greasing, oiling, complete re asssembling of ceiling fan with testing etc, complete all as specified and directed.
All as per item No 21.00 here-in before but having 1400mm sweeps, complete all as specified and as directed.
All as per item No 21.00 here-in before but exhaust fan any make having 300mm sweep, complete all as specified and as directed.
All as per item No 21.00 here-in before but exhaust fan any make having sweep more than 300mm but not more than 450mm, complete all as specified and as directed.
S & F in replacement of gun metal bush with suitable size, gun metal bush for ceiling fan any make, any size and sweep, complete all as specified and as directed.
S & F in replacement of ball bearing of ceiling fans of ball bearing No 6201, complete all as specified and as directed.
All as per item No 26.00 here-in before but ball bearing No 6202, complete all as specified and as directed.
All as per item No 26.00 here-in before but ball bearing No 6203, complete all as specified and as directed.
All as per item No 26.00 here-in before but ball bearing No 6204, complete all as specified and as directed.
All as per item No 26.00 here-in before but ball bearing No 6205, complete all as specified and as directed.
S&F in replacement of canopy (top and bottom) of ceiling fans any make / size with canopy of matching colour, complete all as specified and as directed.
S&F in replacement of down rod of ceiling fan with down rod of 15mm bore, medium grade, GI pipe 0.30 metre long with new clamps, bolts, nuts, split pins washers of suitable size of approved quality, complete all as specified and as directed.
S&F in replacement of down rod of ceiling fan with down rod of 15mm bore, medium grade, GI pipe 0.45 metre long with new clamps, bolts, nuts, split pins washers of suitable size of approved quality, complete all as specified and as directed.
S&F in replacement of capacitor of ceiling fans with capacitor having capacity 2.5mfd, 240 Volts, complete all as specified and as directed.
S&F in replacement of capacitor of ceiling fans with capacitor having capacity 3.15 mfd, 240 Volts, complete all as specified and as directed.
S&F on replacement of capacitor of ceiling fans with capacitor having capacity 4.0 mfd, 240 Volts, complete all as specified and as directed.
S&F in replacement ceiling rose surface bakelite, 65mm x 50mm size, three terminals including PVC mounting block white/ivory, complete all as specified and as directed.
S&F in repair rubber bush insulator reel type suitable for fan hook of any type, complete all as specified and as directed.
S&F in replacement of hanger clamp assembly of down rod for hanging of ceiling fan fixed with nuts, bolts, washers and split pin, complete all as specified and as directed.
S & F energy efficient 200mm PVC air ventilating fan, high speed, complete with louvers and connecting wire up to nearest ceiling rose including taking down old unserviceable fan of any sweep, complete all as specified and as directed. (Make : Havelles model No. Ventil Air DX HS white or equivalent model in Bajaj/Orient/Usha)
S & F energy efficient 300mm PVC air ventilating fan, high speed, complete with louvers and connecting wire up to nearest ceiling rose including taking down old unserviceable fan of any sweep, complete all as specified and directed. (Make : Havelles model No. Ventil Air DB green or equivalent model in Bajaj/Orient/Usha)
S&F in replacement exhaust fan louvers/shutter suitable for sweep 300mm, complete all as specified and as directed.
S&F in replacement exhaust fan louvers/ shutter suitable for sweep 450mm, complete all as specified and as directed.
Comprehensive repair/maintenance of storage type electric heater (geyser) vertical/horizontal type of capacity upto 25/50 ltrs comprising of the following works, complete all as specified and as directed :- (a) Inspection, taking down or dismantling, de-scaling, brushing and thoroughly cleaning the storage tank upto the entire satisfection of Engr-in-Charge. (b) Checking of all stop cock, pressure release valve, fusible plug etc to ensure free functioning of the parts including Supply and replacement of washer/gasket, nuts etc as required. (c) Inspect overflaw and vent pipes and remove blockages (if any). (d) Checking and rectify earth continuity of the electrical circuits of the geyser and power points. (e) Check, maintain and re-fixing thermostat and re-adjust. (f) Visual examination of of fusible plugs for its serviceability. (g) De-scaling the immersion type heating element and siphon assembly with diluted hydrochloride acid or cear pedette solution. (h) Checking of indicator lamp for its serviceability. (j) Re-assembling the geyser, re-installed and testing. Note: (i) Spare parts/components of geysers shall be measured and paid seperately as "supply only" under respective items. (ii) Any minor parts required for smooth functioning of the geyser shall be provided by the contractor without any extra cost to the Govt.)
Supply only heating elements as per site requirement of capacity 1.5 KW, 230 volts ISI marked, complete all as specified and as directed.
Supply only heating elements as per site requirement of capacity 2 KW, 230 volts ISI marked, complete all as specified and as directed
Supply only aperature plate suitable for 50 Ltr capacity, complete all as specified and as directed
Supply only aperature plate suitable for 25 Ltr capacity, complete all as specified and as directed
Supply only high pressure safety valve, complete all as specified and as directed
Supply only geyser NRV (Non Return Valve) 1/2 inch 0.8 MPa pressure, complete all as specified and as directed
Supply only hot and cold "304 grade stainless steel re- enforced flexible connection pipe" 450mm long ISI marked, complete all as specified and as directed
Supply only thermostate adjustable type 11/20 Amp 250 Volt ISI Marked, complete all as specified and as directed
Supply only thermostate adjustable type 7/15 Amp 250 Volt ISI Marked, complete all as specified and as directed
Supply only glass wool insulating packing for 25/ 50 Ltr geyser, complete all as specified and as directed
M & L for shifting of water heater electric type any capacity including fixing arrangment on wall / wooden structure,wall bracket and other connected accessories, complete all as specified and directed.`
Supply, laying & connecting of 15mm bore GI tubing medium grade with all necessary fittings such as bends, elbows, tees, shorts pieces, disminishing pieces, caps & plugs in trenches/on fioor including fittings on walls with saddles including taking up or down old unserviceable GI tubing any type, complete all as specified and directed.
Supply, laying & connecting of 15mm bore GI tubing medium grade with all necessary fittings such as bends, elbows, tees, shorts pieces, disminishing pieces, caps & plugs in trenches/on fioor including fittings on walls with saddles including taking up or down old unserviceable GI tubing any type, complete all as specified and directed.
Dismantling existing unserviceable bib tap stop valves fitted with iron pipes any type, complete all as specified and directed.
S&F in repair for bib tap cast alloy screwed down with crutches or butterfly handle, screw down for iron pipe of for brass ferrule of size 15mm for GI tubing, complete all as specified and directed.
S&F in repair stop valve cast coper alloy screw down high pressure with crutches or butterfly handle screwed both ends for iron pipe or for union of size 15mm for GI tubing, complete all as specified and directed.
S&F MCB SP 6 to 32 Amps, 240V, 10 KA 'B' curve, in the MCB DB complete including connection & testing, complete all as specified and directed.
S&F power unit suitable for load max up to 3.5 KW including sockets 25 Amps, and six module box for mounting of power unit and power socket, complete as specified and directed.
M & L for submain wiring with two single core PVC insulated unsheathed, multistranded flexible copper conductor 1100Volts grade, FRLS type, cables 4.0 Sqmm drawn through in and including rigid PVC heavy duty concealed conduits including 4.0 Sqmm 1100 Volts grade, FRLS type, PVC insulated unsheathed multi stranded flexible copper conductor cable as continuous earth wire and connecting to common earth terminals including taking down old unserviceable sub-main wiring, complete all as specified and directed. Note :- (i) Three runs of cables drawn in conduit shall be measured as one length of sub main. (ii) PVC conduit and its accessories shall deemed to be included the unit quoted rate. (iii) Unit rate shall deemed to be included for cutting chases for conduits and sinking for boxes and making good to wall, floors etc.
S&F energy saving 50W LED 6000K, IP65 flood light luminaire with high power LED complete, including provision of PVC insulated sheathed round flexible wire with multi strand copper conductor of required size including taking down old unserviceable flood light fittings, complete all as specified and directed.
S&F energy saving 100 W LED 6000K, IP65 flood light luminaire with high power LED complete, including provision of PVC insulated sheathed round flexible wire with multi strand copper conductor of required size including taking down old unserviceable flood light fittings, complete all as specified and directed.
S&F energy saving 150W LED 6000K, IP65 flood light luminaire with high power LED complete, including provision of PVC insulated sheathed round flexible wire with multi strand copper conductor of required size including taking down old unserviceable flood light fittings, complete all as specified and directed.
S&F energy saving 90 W LED 6000K, IP66, street light luminaire with high power LED complete, including provision of PVC insulated sheathed round flexible wire with multi strand copper conductor of required size including taking down old unserviceable steet light fittings, complete all as specified and directed.
S&F energy saving 60 W LED 6000K, IP66, street light luminaire with high power LED complete, including provision of PVC insulated sheathed round flexible wire with multi strand copper conductor of required size including taking down old unserviceable steet light fittings, complete all as specified and directed.
S&F in replacement copper cable 1.5 sqmm 3 core PVC insulated round sheathed copper conductor cable, complete all as specified and directed.
S&F in replacement copper cable 2.5 sqmm 3 core PVC insulated round sheathed copper conductor cable, complete all as specified and directed.
S&F in repair rigid non-metallic PVC conduit 20mm dia including required tees, bends ,elbows, reducers, bell mouth tube ends and fixing accessories such as couplers, locknuts, saddles, pipe hoos etc., complete all as specified and directed.
S&F in repair driver for outdoor type LED fitting 30/35 Watt, complete all as specified and directed.
S&F in repair driver for outdoor type LED fitting 45 Watt, complete all as specified and directed.
S&F in repair driver for outdoor type LED fitting 60/75 Watt, complete all as specified and directed.
S&F street light bracket made out of 40mm bore, galvanised iron, medium grade tubing (approx 1.2 mtr in length) including two nos suitable size clamps with nuts, bolts and washers, etc. including painting with two coats of synthetic enameled paint (1st grade quality) over a coat of red oxide primer including taking down old unserviceable one, complete all as specified and directed.
Note: An amount of Rs.85,680.00 on account of Credit Schedule for schedule 'A' part - II shall be deducted from the total amount of BOQ to arrive at the contract sum.
M/S BIJAY KUMAR SHIVA
M/S. KUMAR CONSTRUCTION CO.
M/S BISHAL ENTERPRISES
M/S SARDAR MAL NAHATA
SHRI D P AGARWAL
SHRI PARTHA DUTTA
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .