Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹65.9 LAccepted-AOC | L1 | Accepted-AOC Being Lowest | |
| 2 | L2₹80.5 L+₹12.4 L (18.2%)Rejected-Finance BLOCK C 14 GROUND FLOOR PLOT 618 624 BHIVANDIWALA TERRACE JAGANNATH SHANKARSHETH MARG DHOBI TALAO NEAR KALBADEVI POST OFFICE MUMBAI 400002 | MUMBAI | MAHARASHTRA | 400002 | L2 | Rejected-Finance Being other than lowest | |
| 3 | L3₹87.2 L+₹19.1 L (28.0%)Rejected-Finance NOT AVAILABLE | L3 | Rejected-Finance Being other than lowest | |
| 4 | L4₹1.1 Cr+₹43.1 L (63.4%)Rejected-Finance GARDEN AVENUE PLOT NO 242 243 244 RH 4 SECTOR 21 NERUL NAVI MUMBAI 400 706 | THANE | MAHARASHTRA | 400706 | L4 | Rejected-Finance Being other than lowest |
Tender Value
₹1.0 Cr
EMD Value
₹1.8 L
Closing Date
9 Jul 2020, 6:00 pmClosed
CWE NW MUMBAI
Commander Works Engineer NW Dr Homi Bhabha Road Navy Nagar Colaba Mumbai 05
REPAIR REPLACEMENT AND MAINTENANCE OF EM FITTING FIXTURE INCLUDING DBS MAIN SWITCHES SUB MAIN SERVICE CONNECTION EARTHING AT NOFRA AND OUTLAYING AREA AND DAY TO DAY MAINTENANCE FOR GEYSER WORK AT NOFRA AND OUTLAYING AREA UNDER GE NW NOFRA COLABA MUM
2020_MES_349002_1
8633/CWE(NW)/MUMBAI
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
GE NW NOFRA
Please refer Tender documents.
7 documents required · 7 mandatory
₹1,000
Yes
GE NW NOFRA
₹1.8 L
Yes
6 Oct 2020
2 Jun 2020
11 Jul 2020
2 Jun 2020
9 Jul 2020
24 Jun 2020
2 Jun 2020 - 23 Jun 2020
Amount
Part I Taking down carefully aluminium point wiring (light, fan, socket or power) complete, (fittings such as switches, ceiling roses, pendants, regulators sockets etc to be measured separately) and making good disturbed surfaces of walls, floors complete all as specified and directed.
Material and Labour for point wiring complete with 1.5 sqmm single core multistranded FRLS PVC insulated unsheathed copper conductors 1100 volts grade drawn through and including PVC non-metallic casing and caping of size not less than 25mm width, ISI marked with accessories fixed on wall/ceiling/truss etc with PVC non metallic ISI marked terminal boxes/ modular Cover plate concealed in wall including one FRLS PVC insulated & sheathed multistranded green colour copper conductor 1.5 sqmm as earth continuity conductor connected to common earth as earth dolly complete all as specified and directed. Make of wire - Polycab / Finolex / Havells Make of casing caping - Pressfit / Precision
(a) One light point controlled by one switch SP one way.
(b) One ceiling fan point controlled with one 5A switch
(c) One exhaust fan point controlled with one 5A switch
(d) One 3 pin socket outlet 5Amps on independant board.
(e) One 3 pin socket outlet 5Amps on same board with other switches.
(f) One bell point controlled by one bell push 5 Amps.
Material and Labour for point wiring complete with 4 sqmm single core multistranded FRLS PVC insulated unsheathed copper conductors 1100 volts grade drawn through and including PVC non-metallic casing and caping of size not less than 25mm width, ISI marked with accessories fixed on wall/ceiling/truss etc with PVC non metallic ISI marked terminal boxes / modular Cover plate concealed in wall including one FRLS PVC insulated & unsheathed multistranded green colour copper conductor 4 sqmm as earth continuity conductor connected to common earth as earth dolly complete all as specified and directed. Make of wire - Polycab / Finolex / Havells Make of casing caping - Pressfit / Precision
Supply and fix in repair Modular Switch, 6Amp, One way, 1 module complete all as specified and directed.. Make- Legrand (Aretor)/ Schneider (Zencelo)/ Goldmedal (Nixon)
Supply and fix in repair Modular blank plate, One way, 1 module complete all as specified and directed.. Make- Legrand (Aretor)/ Schneider (Zencelo)/ Goldmedal (Nixon)
Supply and fix in repair Modular Switch, 16Amp, One way, 1 module complete all as specified and directed.. Make- Legrand (Aretor)/ Schneider (Zencelo)/ Goldmedal (Nixon)
Supply and fix in repair Modular type bell push , 6Amp, 1 module complete all as specified and directed.. Make- Legrand (Aretor)/ Schneider (Zencelo)/ Goldmedal (Nixon)
Supply and fix in repair Bell electric AC 230Volt single pole musical type with ISI mark complete all as specified and directed.. Make - Legrand /Gold Medal / Anchor
Supply and fix in repair Modular type, electronic fan regulator (5 step), 120 Watts, 230 volts, 2 module complete all as specified and directed. Make- Legrand (Aretor)/ Schneider (Zencelo)/ Goldmedal (Nixon)
Supply and fix in repair ceiling rose surface bakelite with ISI mark, flush type with ISI mark three terminals complete all as specified and directed.. Make - Legrand /Gold Medal / Anchor
Supply and fix in repair Modular Socket oulet, 6 Amps, 2/3 pin combined, 2 module complete all as specified and directed.. Make- Legrand (Aretor)/ Schneider (Zencelo)/ Goldmedal (Nixon)
Supply and fix in repair Modular Socket oulet, 6/16 Amps, 2/3 pin combined, 2 module complete all as specified and directed.. Make- Legrand (Aretor)/ Schneider (Zencelo)/ Goldmedal (Nixon)
M & L required for filling wall cavity & cutting chases in cement mortar 1:3 not exc 10 cm in girth to ends or edges including taking down existing metal or wooden sinking box & making good to wall surface for concealed modular metal flush box or concealed conduit wiring complete all as specified and directed.
Supply and fix in repair Modular white cover plate with Frame 1 Module complete all as specified and directed.. Make- Legrand (Aretor)/ Schneider (Zencelo)/ Goldmedal (WEGA)
Supply and fix in repair Modular white cover plate with Frame 2 Module complete all as specified and directed.. Make- Legrand (Aretor)/ Schneider (Zencelo)/ Goldmedal (WEGA)
Supply and fix in repair Modular white cover plate with Frame 3 Module complete all as specified and directed.. Make- Legrand (Aretor)/ Schneider (Zencelo)/ Goldmedal (WEGA)
Supply and fix in repair Modular white cover plate with Frame 4 Module complete all as specified and directed.. Make- Legrand (Aretor)/ Schneider (Zencelo)/ Goldmedal (WEGA)
Supply and fix in repair Modular white cover plate with Frame 6 Module complete all as specified and directed.. Make- Legrand (Aretor)/ Schneider (Zencelo)/ Goldmedal (WEGA)
Supply and fix in repair Modular white cover plate with Frame 8 Module complete all as specified and directed.. Make- Legrand (Aretor)/ Schneider (Zencelo)/ Goldmedal (WEGA)
Supply and fix in repair Modular white cover plate with Frame 12 Module complete all as specified and directed.. Make- Legrand (Aretor)/ Schneider (Zencelo)/ Goldmedal (WEGA)
Supply and fix in repair Modular metal flush box 1 module complete all as specified and directed.. Make- Legrand (Aretor)/ Schneider (Zencelo)/ Goldmedal (WEGA)
Supply and fix in repair Modular metal flush box 2 module complete all as specified and directed.. Make- Legrand (Aretor)/ Schneider (Zencelo)/ Goldmedal (WEGA)
Supply and fix in repair Modular metal flush box 3 module complete all as specified and directed. Make- Legrand (Aretor)/ Schneider (Zencelo)/ Goldmedal (WEGA)
Supply and fix in repair Modular metal flush box 4 module complete all as specified and directed. Make- Legrand (Aretor)/ Schneider (Zencelo)/ Goldmedal (WEGA)
Supply and fix in repair Modular metal flush box 6 module complete all as specified and directed. Make- Legrand (Aretor)/ Schneider (Zencelo)/ Goldmedal (WEGA)
Supply and fix in repair Modular metal flush box 8 module complete all as specified and directed. Make- Legrand (Aretor)/ Schneider (Zencelo)/ Goldmedal (WEGA)
Supply and fix in repair Modular metal flush box 12 module complete all as specified and directed. Make- Legrand (Aretor)/ Schneider (Zencelo)/ Goldmedal (WEGA)
Supply and fix in repair baton intergrated LED channel 1x18 WH accessories internally prewired and including connecting up with twin core twisted flexible copper conductor cable with suitable size complete all as specified and directed. Make- Philips / Havells/ Jaquar or equivalent
Supply and fix in repair baton intergrated LED channel 1x10 WH accessories internally prewired and including connecting up with twin core twisted flexible copper conductor cable with suitable size complete all as specified and directed.. Make- Philips / Havells/ Jaquar or equivalent.
Supply and fix in repair LED lamp suitable for 14 watts, 240 volts, single phase, 50 Hzs, Lumen 1450 AC supply complete all as specified and directed.. Make- Philips / Havells/ Jaquar or equivalent
Material and Labour in repair for Lamp holder, PVC /Polycarbonate type with cord grip cap suitable for pendant fittings complete all as specified and directed. Make- Anchor / Havells/ Legrand
Supply and fix in repair sheet metal enclosure 12 way Double door type having protection IP-42, with 200 Amps rated bus bar connecting with existing wiring circuits by providing copper pin terminals of suitable size complete all as specified and directed. :- Make - Legrand/ Schneider/ GE
(a) MCB SPN 63 Amps, 240 Volts - 01 No Make - Legrand/ Schneider/ GE
(b) MCB SP 6-32 Amps, 240 Volts - 10 Nos. Make - Legrand/ Schneider/ GE
Supply and fix in repair MCB, DB, SPN 8 way double door with protection type IP-42 with 200 Amps rated bus bar connecting with existing wiring circuits by providing copper pin terminals of suitable size complete all as specified and directed. Make - Legrand/ Schneider/ GE
S&F MCB SPN 40 Amps 240 Volts-01 No (C Series). Make - Legrand/ Schneider/ GE
S&F MCB SP 6- 32 Amps 240 Volts - 06 Nos (C Series). Make - Legrand/ Schneider/ GE
Supply and fix in repair single phase sheet metal powder coated double door distribution board 4 way complete all as specified and directed. (a) MCB SPN 40Amps 240Volts, 10KA - 1 No ('C' Series) (b) MCB SP 6 - 32Amps 240Volts - 2No ('C' Series) Make - Legrand/ Schneider/ GE
Supply and fix in repairs sheet metal enclosure 2 way without bus bar with MCB complete all as specified and directed. Make - Legrand/ Schneider/ GE
Isolator DP 63 Amps Breaking capacity 10 KA. (C series) complete all as specified and directed. . Make - Legrand/ Schneider/ GE
Supply and fix in repair Plug and Socket enclosure, in sheet metal enclosure with MCB, SP 20 Amps 240 Volts complete with metal clad socket for window type air conditioners complete all as specified and directed.. Make - Legrand/ Schneider/ GE
Taking down old unserviceable submain cable of any size and capacity and finishing wall surfaces complete all as specified and directed..
Supply and fix submain wiring in repair with two single core FRLS unsheathed 1100 volts grade cable with stranded copper conductor of size 4 Sqmm in and including PVC casing caping not less than 25mm width, ISI marked including 1 single core cable with stranded copper conductor of size 4 sqmm (green colour) for earthing complete all as specified and directed.. Note :- (i) Two runs of 4Sqmm cable, 1 run of PVC casing & caping and 1 run of 4 Sqmm cable shall be measured as 1 RM. (ii) Each submain wiring shall run in seperate PVC casing caping Make of wire - Polycab / Finolex / Havells Make of casing caping - Pressfit / Precision
Supply and fix in repair submain wiring two single core 6 Sqmm for sub main witing with copper conductor multistranded PVC insulated and unsheathed 1100Volts grade in and including PVC casing capping with fixing accessories including one run of 4.0 Sqmm copper conductor complete all as specified and directed.. Note :- (i) Two runs of 06 Sqmm cable, one run of 4.0 Sqmm earth cable and one run of PVC casing Capping shall be measured as one running meter. (ii) Each submain wiring shall run in seperate PVC casing caping Make of wire - Polycab / Finolex / Havells Make of casing caping - Pressfit / Precision
Supply and fix submain wiring in repair 2 single core FRLS unsheathed 1100 volts grade cable with stranded copper conductor of size 10 Sqmm in and including PVC casing caping not less than 25mm dia including 1 single core cable with stranded copper conductor of size 10 sqmm (green colour) for earthing complete all as specified and directed.. Note :- (i) Two runs of 10 Sqmm cable, 1 run of PVC casing caping and 1 run of 10 Sqmm cable shall be measured as 1 RM. (ii) Each submain wiring shall run in seperate PVC casing caping Make of wire - Polycab / Finolex / Havells Make of casing caping - Pressfit / Precision
Material and labour for painting of ceiling fans complete, in situ with synthetic enamel paint by spray painting including filling cavities with filler, one coat after cleaning all dust etc complete all as specified and directed.
Material and labour for painting of exhaust fans complete, in situ with synthetic enamel paint by spray painting including filling cavities with filler, one coat after cleaning all dust complete all as specified and directed.
Rewinding of unserviceable ceiling fans of size1200/1400mm sweep with approved copper enamelled wire of suitable gauge, varnishing, replacing existing split/quater pins, rubber bushing, capacitor 2.5 Mfd and testing complete all as specified and directed.
Rewinding of exhaust fans of size 225/300 mm sweep with approved copper enamelled wire of suitable gauge varnishing replacement of capacitor, rubber packing, suitable size bearing , bush etc and testing complete all as specified and directed.
Supply and fix in repair aluminium strips 25 x 3.15 mm size with saddles and fixing screws etc for roof conductor and down conductor complete all as specified and directed.
S & F in repairs air terminiation single pointed aluminium rod 12mm dia and 300mm long complete all as specified and directed.
S & F in repair test points terminal block made of gun metal or phosphorus bronze size 75x75x25mm drilled and screwed including 3nos 8mm dia 25mm long hexagonal head screw building lightning earth test point complete all as specified and directed.
Supply and lay in repair 50 mm dia GI tubing light grade for fixed to walls/ceilings/floors complete all as specified and directed.
Material and labour Earthing complete with galvanised steel earth plate eletrode 60cm x 60cm x 6 mm thick buried directly in ground (earth pit not less than 2.25 metres deep below normal ground level) with top edge of plate not less than 1.5 meters below normal ground level, connecting to galvanised earth strip 24 x 4 mm by means of bolts, nuts, check nuts and washer of galvanised iron or steel upto test point all as shown in electrical plate No 3 of SSR Part-I connected to test point including PCC earth pit with CI cover, GI funnel with wire mesh, GI protection pipe of 50mm dia for earth lead protection from earth plate to test point and 20mm GI pipe for watering, excavation and earth work in any type of soil, filling the pit with charcoal and common salt surrounding the earth plate complete all as specified and directed. including testing on completeion. Note :- Cost of strip upto 7.5m long galvanised earth lead 25 x 4mm size & PCC earth pit to be casted on the PCC base of 75cmx75cmx40mm is deemed to be included in the quoted rate.
Materal and labour for CPT Cirprotec CPT-L ESE Lighting rod with stainles steel body type advance lightning protection system in compliance with standard NFC 17-102 & UNE 21186-96, working on principle of early streamer emission technology which will offer level 1 protection for upto 42 mtrs radius when mounted on the RCC concrete base on building at a height of 4.5 mtrs from the place to protected complete all as specified and directed.. make:- NIMBUS-JEF Techno or erico as approved by GE
Supply and erection of mounting structure of 4.5 mtrs height with base plate suitable for roof mounting on RCC concrete base on building complete all as specified and directed.. Make:- NIMPUS-JEF Techno or erico as approved by GE
Supply and fixing of 1x 50 sqmm copper conductor with 0.5 mm thick PVC sheathed cable complete all as specified and directed.
Supply and fixing 4 digital electromechanical lightning event counter in weather proof resistance complete all as specified and directed. Make:- JEF Techno or erico as approved by GE
Supply and fixing of test link for connecting the earth pit and down conductor complete all as specified and directed.. Make:- JEF Techno or erico as aaproved by GE
Material & labour for maintanance free enviroment friendly earth elctrode set comprising of 17.2mm dia, 3m long rod low carbon steel molecular copper bounded for a thickness of 250 micro OHMS, highly conductive ANS/INSF STD-60 certified carbon bound backfill compound which shall set like concrete according to BS 7430 & IEEE 80 (each bag shall contain 50 Ibs) complete all as specified and directed.. make:- JEF Ecosfe or erico as approved by GE
Material and labour for PCC pit 1:2:4 type B-1, cover reinforced with XPM, weight not less than4kg/sqm and 6mm dia bar handle earth pit angle iron frame of size 25x25x3mm complete all as specified and directed.
Supply and fix in replacement of GI piupe light grade 40mm dia for support to air termination rod including fixing with clamp, nuts, bolts complete all as specified and directed.
Road/PCC cutting neccesary for laying of 40mm GI pipe for cable protection and making good complete all as specified and directed.
Part II Taking down carefully aluminium point wiring (light, fan, socket or power) complete, (fittings such as switches, ceiling roses, pendants, regulators sockets etc to be measured separately) and making good disturbed surfaces of walls, floors complete all as specified and directed
Material and Labour for point wiring complete with 4 sqmm single core multistranded FRLS PVC insulated unsheathed copper conductors 1100 volts grade drawn through and including PVC non-metallic casing and caping of size not less than 25mm width, ISI marked with accessories fixed on wall/ceiling/truss etc with PVC non metallic ISI marked terminal boxes / modular boxes surfaced on wall including one FRLS PVC insulated & unsheathed multistranded green colour copper conductor 4 sqmm as earth continuity conductor connected to common earth as earth dolly complete all as specified and directed. Make of wire- Polycab/ Finolex/ Havells Make of casing caping- Precision/ Pressfit
Supply and fix in repair Modular Switch, 16Amp, One way, 1 module complete all as specified and directed. Make- Legrand (Aretor)/ Goldmedal (Nixon)/ Schneider (Zencelo)
Supply and fix in repair Modular Socket oulet, 6/16 Amps, 2/3 pin combined, 2 module complete all as specified and directed. Make- Legrand (Aretor)/ Goldmedal (Nixon)/ Schneider (Zencelo)
Supply and fix in repair Modular white cover plate with Frame 3 Module complete all as specified and directed. Make- Legrand (Aretor)/ Goldmedal (WEGA)/ Schneider (Zencelo)
Supply and fix in repair Modular PVC flush box 3 module complete all as specified and directed. Make- Legrand (Aretor)/ Goldmedal (WEGA)/ Schneider (Zencelo)
S&F in repair switch socket combination multipurpose 2 in 1 for 3 pin 15 Amps & 3pin 5 Amp controlled by one switch flush type complete all as specified and directed. Make- Anchor / Legrand/ Goldmedal
Supply and fix in repair PVC Box for Switches, with fixing accessories complete all as specified and directed :-
All as per item above but size 4”x4”
All as per item above but size 4” x 7”
Supply and fix in repair single phase sheet metal powder coated double door distribution board 4 way complete all as specified and directed :- Make- Legrand/ Schneider/GE (a) MCB SPN 40Amps 240Volts, 10KA - 1 No ('C' Series) (b) MCB SP 6 - 32Amps 240Volts - 2No ('C' Series)
Supply and fix in repairs sheet metal enclosure 2 way without bus bar with MCB complete all as specified and directed Make- Legrand/ Schneider/GE
Isolator DP 63 Amps Breaking capacity 10 KA complete all as specified and directed. (C series) .Make- Legrand/ Schneider/GE
Supply and fix in repair , MCB SP 6-32 Amps, 10 KA rating "C" series complete all as specified and directed. Make- Legrand/ Schneider/GE
Taking down old unserviceable submain cable of any size and capacity and finishing wall surfaces complete all as specified and directed.
Supply and fix in repair submain wiring two single core 6 Sqmm for sub main witing with copper conductor multistranded PVC insulated and unsheathed 1100Volts grade in and including PVC casing capping with fixing accessories including one run of 6.0 Sqmm copper conductor complete all as specified and directed. Note :- (i) Two runs of 06 Sqmm cable, one run of 6.0 Sqmm earth cable and one run of PVC casing Capping shall be measured as one running meter. (ii) Each submain wiring shall run in seperate PVC casing caping Make of wire- Polycab/ Finolex/ Havells Make of casing caping- Precision/ Pressfit
Supply and fix submain wiring in repair 2 single core FRLS unsheathed 1100 volts grade cable with stranded copper conductor of size 10 Sqmm in and including PVC casing caping not less than 25mm dia including 1 single core cable with stranded copper conductor of size 10 sqmm (green colour) for earthing complete all as specified and directed. Note :- (i) Two runs of 10 Sqmm cable, 1 run of PVC casing caping and 1 run of 10 Sqmm cable shall be measured as 1 RM. (ii) Each submain wiring shall run in seperate PVC casing caping Make of wire- Polycab/ Finolex/ Havells Make of casing caping- Precision/ Pressfit
Supply and fix in repair heating element 2KW /3KW, of instant type water heater as per existing capacity at site complete all as specified and directed
Supply and fix in repair heating element 1KW, of storage type water heater 25 Ltr capacity at site complete all as specified and directed
Supply and fix in repair heating element 1.5 KW, of storage type water heater 50 Ltr capacity at site complete all as specified and directed
Supply and fix in repair thermostat / thermal cut out suitable for storage type water heater 25/50 Ltr capacity complete all as specified and directed.
Supply and fix in repair thermostat / thermal cut out suitable for instant type water heater 01 /06 Ltr capacity complete all as specified and directed.
Supply and fix in repair hot water extension pipe made out of copper chromium plated 450mm long with brass adaptor and fixing in position complete all as specified and directed
Supply and fix in repair 450mm long PVC connector with brass adaptor, washer and fixing in position complete all as specified and directed
Taking down and Supply & fix PVC cable multistranded insulated copper conductor 1100 volts grade of 4 sqmm 3 core, ISI marked complete all as specified and directed. Make- Polycab/ Havells/ finolex
Supply & fix in repair MCB DB, TPN 8 way vertical type, 415 V with 200 Amps rated bus bar and double door connecting with existing wiring circuits by providing copper pin terminals of suitable size complete all as specified and directed : - (a) MCCB 3 Pole, 415 V fixed type, 160 Amps with breaking capacity 25 KA-01 Nos (incoming) MAKE: Legrand, Schneider, GE (b) MCB TP 63 Amps, 10KA - 06 Nos (C Series) (Outgoing) MAKE: Legrand, Schneider, GE (c) MCB SP 40 Amps, 10KA - 06 Nos (C Series) (Outgoing) MAKE: Legrand, Schneider, GE
Taking down old UNSV water heater of any type / capacity from site & deposit to MES store yard complete all as specified and directed.
Fixing only , testing and commissioning of storage type water heater (geyser) vertical type of 25 Ltrs capacity , single phase, vertical type, Rust Resistant, ABS made with thermal cut off with power consumption 1500 watts, ISI marked, BEE 5 star rating including fixing on wall with chroumium plated screws & nut bolts , connection to water pipe line and electric connection complete all as specified and directed Note:- Geyser shall be issued by MES Department as Sch 'B' Stores.
Fixing only, testing and commissioning of Storaget type water heater (geyser) vertical type of 6 Ltrs capacity , single phase, vertical type, Rust Resistant, ABS made with thermal cut off with power consumption 1500 watts, ISI marked, BEE 5 star rating including fixing on wall with chroumium plated screws & nut bolts connected to water loft tank alongwith material required to connect with pipe line and electric connection complete all as specified and directed Note:- Geyser shall be issued by MES Department as Sch 'B' Stores.
Material and Labour for replacement of Inner tank made of SS 304 suitable for electric water heater capacity 25 Ltrs including PUF insulation for trap the heat in inner tank, high pressure withstanding enabling to use in high rise building complete all as specified and directed
Material and Labour for replacement of Outer body made of CRCA, colour- Ivory/white suitable for electric water heater capacity 25 Ltrs for multiple safety for dry heating & overheating complete all as specified and directed
Material and Labour for replacement of Inner tank made of SS 304 suitable for electric water heater capacity 50 Ltrs including PUF insulation for trap the heat in inner tank, high pressure withstanding enabling to use in high rise building complete all as specified and directed
Material and Labour for replacement of Outer body made of CRCA, colour- Ivory/white suitable for electric water heater capacity 50 Ltrs for multiple safety for dry heating & overheating complete all as specified and directed
Material and Labour for replacement of Inner tank made of SS 304 suitable for electric water heater capacity 06 Ltrs including PUF insulation for trap the heat in inner tank, high pressure withstanding enabling to use in high rise building complete all as specified and directed
Material and Labour for replacement of Inner tank made of SS 304 suitable for electric water heater capacity 01 Ltrs including PUF insulation for trap the heat in inner tank, high pressure withstanding enabling to use in high rise building complete all as specified and directed
Supply and fix RCCB with MCB of 2 pole, 25 Amp rating,IP 20 with sensitivity of 30 mA suitable for 240Volts including metal box 2P, IK 08 complete all as specified and directed Make- Legrand/ ABB/ Schneider
Supply only garbage bag of size suitable for garbage bin as per item 14 above (30 pieces bag)
Supply and fix in repair 15 Amps plug top, AC 230 volts, ISI marked complete all as specified and directed. Make- Anchor/ Havells/ Legrand
Supply and fix in repair 15 Amps plug top, AC 230 volts, ISI marked complete all as specified and directed. Make- Anchor/ Havells/ Legrand
AGRAWAL ASSOCIATES
SHREE JAGDISH FURNITURE CO.
M/s S.D Construction Co
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .