Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹13.3 CrAccepted-AOC 1 INFRONT OF SIDDHI VINAYAK GANESH MANDIR SATYAM VIHAR COLONY RAIPURA RAIPUR CHHATTISGARH 492013 | RAIPUR | CHHATTISGARH | 492013 | ₹13.3 Cr | L1 | Accepted-AOC After deduction of sch of credit Rs 373696.40 |
| 2 | L2₹13.4 CrRejected-Finance | ₹13.4 Cr | L2 | Rejected-Finance Not Being lowest |
| 3 | L3₹13.5 CrRejected-Finance BRICHGUNJ JUNGLIGHAT PO SRI VIJAYA PURAM 744103 | SRI VIJAYA PURAM | SOUTH ANDAMAN | ANDAMAN AND NICOBAR ISLANDS | 744103 | ₹13.5 Cr | L3 | Rejected-Finance Not Being lowest |
| 4 | L4₹14.2 CrRejected-Finance POST BOX NO 539 JUNGLIGHAT P O SRI VIJAYA PURAM 744 103 | SRI VIJAYA PURAM | SOUTH ANDAMAN | ANDAMAN AND NICOBAR ISLANDS | 744103 | ₹14.2 Cr | L4 | Rejected-Finance Not Being lowest |
| 5 | L5₹17.8 CrRejected-Finance C O AMBU HOTEL NEAR GOVT POLYTECHNIC DOLLY GUNJ PORT BLAIR 744 103 | PORT BLAIR | SOUTH ANDAMANS | ANDAMAN AND NICOBAR ISLANDS | 744103 | ₹17.8 Cr | L5 | Rejected-Finance Not Being lowest |
| Sl No | Description | Qty | Unit | ANANYA ENTERPRISES L1 | BHARAT MULTITECH INDUSTRIES PVT LTD L4 | P NAIDU L2 | Jas & Co L3 | City Constructie Pvt Ltd L5 |
|---|---|---|---|---|---|---|---|---|
| 1.00 | NOTE: Schedule 'A' Part - I to Part-XVII are prepriced by MES. Bidders shall insert their lumpsum amount in Green coloured field under col-6 only
Lumpsum price worked out by the contractor for "BUILDINGS & STRUCTURES" as listed in Schedule "A" Part – I | 1 | Each Job | 4,44,41,320 ₹4.4 Cr | 6,71,34,760 ₹6.7 Cr | 6,20,00,000 ₹6.2 Cr | 5,52,81,000 ₹5.5 Cr | 8,50,00,000 ₹8.5 Cr |
| 2.00 | Lumpsum price worked out by the contractor for "EXCAVATION, EARTH WORK" as listed in Schedule "A" Part – II | 1 | Each Job | 3,09,983.76 ₹3.1 L | 3,39,660 ₹3.4 L | 3,80,000 ₹3.8 L | 3,40,000 ₹3.4 L | 2,00,000 ₹2 L |
| 3.00 | Lumpsum price worked out by the contractor for "INTERNAL ELECTRIFICATION" as listed in Schedule "A" Part – III | 1 | Each Job | 24,29,276.41 ₹24.3 L | 35,85,000 ₹35.9 L | 50,00,000 ₹50 L | 26,98,575 ₹27.0 L | 38,00,000 ₹38 L |
| 4.00 | Lumpsum price worked out by the contractor for "INTERNAL WATER SUPPLY" as listed in Schedule "A" Part – IV | 1 | Each Job | 80,056.69 ₹80,056.69 | 1,46,100 ₹1.5 L | 1,50,000 ₹1.5 L | 87,800 ₹87,800 | 1,01,500 ₹1.0 L |
| 5.00 | Lumpsum price worked out by the contractor for "EXTERNAL WATER SUPPLY" as listed in Schedule "A" Part – V | 1 | Each Job | 25,683.1 ₹25,683.10 | 52,900 ₹52,900 | 49,000 ₹49,000 | 30,700 ₹30,700 | 42,000 ₹42,000 |
| 6.00 | Lumpsum price worked out by the contractor for "EXTERNAL ELECTRIC SUPPLY" as listed in Schedule "A" Part – VI | 1 | Each Job | 14,29,218.11 ₹14.3 L | 33,44,978 ₹33.4 L | 28,00,000 ₹28 L | 16,00,000 ₹16 L | 27,00,000 ₹27 L |
| 7.00 | Lumpsum price worked out by the contractor for "ROAD / PATH / CULVERT" as listed in Schedule "A" Part – VII | 1 | Each Job | 13,99,385.1 ₹14.0 L | 22,33,060 ₹22.3 L | 26,65,000 ₹26.6 L | 16,90,000 ₹16.9 L | 18,31,100 ₹18.3 L |
| 8.00 | Lumpsum price worked out by the contractor for "SEWAGE DISPOSAL" as listed in Schedule "A" Part – VIII | 1 | Each Job | 7,77,974.49 ₹7.8 L | 11,58,684 ₹11.6 L | 15,00,000 ₹15 L | 9,50,000 ₹9.5 L | 10,50,000 ₹10.5 L |
| 9.00 | Lumpsum price worked out by the contractor for "AREA DRAINAGE" as listed in Schedule "A" Part – IX | 1 | Each Job | 4,27,153.12 ₹4.3 L | 6,28,860 ₹6.3 L | 8,50,000 ₹8.5 L | 5,65,000 ₹5.7 L | 6,00,000 ₹6 L |
| 10.00 | Lumpsum price worked out by the contractor for "PILE FOUNDATION" as listed in Schedule "A" Part – X | 1 | Each Job | 1,82,81,107.78 ₹1.8 Cr | 2,68,38,222 ₹2.7 Cr | 3,20,00,000 ₹3.2 Cr | 2,28,00,000 ₹2.3 Cr | 3,47,29,000 ₹3.5 Cr |
Updated dates
Tender Value
₹13.8 Cr
EMD Value
₹10.2 L
Closing Date
23 Oct 2025, 6:00 pmClosed
HQ CE ANZ Sri Vijaya Puram
Brichgunj,Junglighat PO, 744103
PROVISION OF AUTO CONTROL SHOP AT NSRY SRI VIJAYA PURAM
2025_MES_722185_1
801237/E8
Open Tender
Civil Works
730 days
GE P North
As per Tender
8 documents required · 8 mandatory
₹3,000
GE P North
₹10.2 L
Yes
18 Dec 2025
11 Sept 2025
27 Oct 2025
11 Sept 2025
23 Oct 2025
9 Oct 2025
Amount
NOTE: Schedule 'A' Part - I to Part-XVII are prepriced by MES. Bidders shall insert their lumpsum amount in Green coloured field under col-6 only Lumpsum price worked out by the contractor for "BUILDINGS & STRUCTURES" as listed in Schedule "A" Part – I
Lumpsum price worked out by the contractor for "EXCAVATION, EARTH WORK" as listed in Schedule "A" Part – II
Lumpsum price worked out by the contractor for "INTERNAL ELECTRIFICATION" as listed in Schedule "A" Part – III
Lumpsum price worked out by the contractor for "INTERNAL WATER SUPPLY" as listed in Schedule "A" Part – IV
Lumpsum price worked out by the contractor for "EXTERNAL WATER SUPPLY" as listed in Schedule "A" Part – V
Lumpsum price worked out by the contractor for "EXTERNAL ELECTRIC SUPPLY" as listed in Schedule "A" Part – VI
Lumpsum price worked out by the contractor for "ROAD / PATH / CULVERT" as listed in Schedule "A" Part – VII
Lumpsum price worked out by the contractor for "SEWAGE DISPOSAL" as listed in Schedule "A" Part – VIII
Lumpsum price worked out by the contractor for "AREA DRAINAGE" as listed in Schedule "A" Part – IX
Lumpsum price worked out by the contractor for "PILE FOUNDATION" as listed in Schedule "A" Part – X
Lumpsum price worked out by the contractor for "LIGHTNING PROTECTION" as listed in Schedule "A" Part – XI
Lumpsum price worked out by the contractor for "EARTHING USER EQUIPMENT" as listed in Schedule "A" Part – XII
Lumpsum price worked out by the contractor for "COOLING APPLIANCES" as listed in Schedule "A" Part – XIII
Lumpsum price worked out by the contractor for "PVC CONDUIT FOR TELEPHONES" as listed in Schedule "A" Part – XIV
Lumpsum price worked out by the contractor for "FIRE ALARM SYSTEM" as listed in Schedule "A" Part – XV
Lumpsum price worked out by the contractor for "FIRE FIGHTING" as listed in Schedule "A" Part – XVI
Lumpsum price worked out by the contractor for "DISMANTLING / DEMOLITION" as listed in Schedule "A" Part – XVII
Schedule "A" Part - XVIII [Miscellaneous Items] [Tenderer has to quote unit rate under Col 6] S & F 15mm bore CP two way brass bib cock with flange screwed for polyethylene and unplasticised PVC pipes of ferrule and fixed complete all as specified and as directed.
M&L for cutting cast Iron pipes / GI pipes of size 100mm dia. and providing of reducer 'T' of size 100mm x 100mm x 40mm including necessary earthwork, refilling, removal etc., complete all as specified and as directed.
Supply, install, testing and commissioning of LT cubical outdoor type panel made out of 3.15mm thick CRCA sheet fabricated, totally enclosed, CPRI approved with front and rear opening, powder coated after seven tank process, mounted on MS equal angle iron 5mm thick dust and vermin proof with both side openable hinged door and locking arrangement with IP-65 protection, danger notice plate, stickering of switchgear about load termination, cable connector for connecting multi cables located in cable chamber terminated from the swtchgear, all materials rust proof as per IS-8623, Aluminium bus bar of capacity not less than 800A with insulators suitable for three phase and capacity and powder coated painting with synthetic enamel paint over a coat of primer fixed on and including PCC 1:3:6 type C-1 coping over PCC 1:4:8, type D2 foundation suitable for accommodating and including the following:- (a) MCCB, 4P, 630 A, 50Hz, 415V with rupturing capacity 36 KA - 01 No (Main Incoming) (b) MCCB, 4P, 400 A, 50Hz, 415V with rupturing capacity 36 KA - 01 No (for user panel 1) (c) MCCB, 4P, 320 A, 50Hz, 415V with rupturing capacity 36 KA - 02 Nos (for MES panel spare) (d) MCB 4P, 32A, 50Hz, 415V with rupturing capacity 10 KA - 01 No (misc) (e) Multifunction electronic digital display meter Cl-1 with programmable CT/PT measuring VI, P, PF, KVAR etc., - 1No. (f) Analog Time switch with 3 Pole contactor and manual switch - 1No. (g) Indicator lamp LED for R, Y, B with MCB - 1set.
Supply, install, testing and commissioning of LT cubical outdoor type panel made out of 3.15mm thick CRCA sheet fabricated, totally enclosed, CPRI approved with front and rear opening, powder coated after seven tank process, mounted on MS equal angle iron 5mm thick dust and vermin proof with both side openable hinged door and locking arrangement with IP-65 protection, danger notice plate, stickering of switchgear about load termination, cable connector for connecting multi cables located in cable chamber terminated from the swtchgear, all materials rust proof as per IS-8623, Aluminium bus bar of capacity not less than 600A with insulators suitable for three phase and capacity and powder coated painting with synthetic enamel paint over a coat of primer fixed on and including PCC 1:3:6 type C-1 coping over PCC 1:4:8, type D2 foundation suitable for accommodating and including the following:- (a) MCCB, 4P, 400 A, 50Hz, 415V with rupturing capacity 36 KA - 01 No (Incomer) (b) MCCB, 3P, 250 A, 50Hz, 415V with rupturing capacity 25 KA - 01 No (c) MCCB, 3P, 100 A, 50Hz, 415V with rupturing capacity 25 KA - 02 Nos (d) MCCB, 3P, 50 A, 50Hz, 415V with rupturing capacity 25 KA - 02 Nos (e) MCCB, 3P, 32 A, 50Hz, 415V with rupturing capacity 18 KA - 03 Nos (f) Multifunction electronic digital display meter Cl-1 with programmable CT/PT measuring VI, P, PF, KVAR etc., - 1No. (g) Indicator lamp LED for R, Y, B with MCB - 1set.
Supply, install, testing and commissioning of LT cubical outdoor type panel made out of 3.15mm thick CRCA sheet fabricated, totally enclosed, CPRI approved with front and rear opening, powder coated after seven tank process, mounted on MS equal angle iron 5mm thick dust and vermin proof with both side openable hinged door and locking arrangement with IP-65 protection, danger notice plate, stickering of switchgear about load termination, cable connector for connecting multi cables located in cable chamber terminated from the swtchgear, all materials rust proof as per IS-8623, Aluminium bus bar of capacity not less than 480A with insulators suitable for three phase and capacity and powder coated painting with synthetic enamel paint over a coat of primer fixed on and including PCC 1:3:6 type C-1 coping over PCC 1:4:8, type D2 foundation suitable for accommodating and including the following:- (a) MCCB, 4P, 320 A, 50Hz, 430V with rupturing capacity 36 KA - 01 No (Incomer) (b) MCCB, 3P, 100 A, 50Hz, 430V with rupturing capacity 25 KA - 01 No (c) MCCB, 3P, 63 A, 50Hz, 415V with rupturing capacity 18 KA - 01 No (d) MCCB, 3P, 40 A, 50Hz, 415V with rupturing capacity 18 KA - 04 Nos (e) MCCB, 3P, 32 A, 50Hz, 415V with rupturing capacity 18 KA - 02 Nos (f) Multifunction electronic digital display meter Cl-1 with programmable CT/PT measuring VI, P, PF, KVAR etc., - 1No. (g) Indicator lamp LED for R, Y, B with MCB - 1set.
Supply, install, testing and commissioning of LT cubical indoor type panel made out of 2mm thick CRCA sheet fabricated, totally enclosed, CPRI approved with front and rear opening, powder coated after seven tank process, mounted on MS equal angle iron 5mm thick dust and vermin proof with both side openable hinged door and locking arrangement with IP-65 protection, danger notice plate, stickering of switchgear about load termination, cable connector for connecting multi cables located in cable chamber terminated from the swtchgear, all materials rust proof as per IS-8623, Aluminium bus bar of capacity not less than 300A with insulators suitable for three phase and capacity and powder coated painting with synthetic enamel paint over a coat of primer fixed on and including PCC 1:3:6 type C-1 coping over PCC 1:4:8, type D2 foundation suitable for accommodating and including the following:- (a) MCCB, 4P, 250 A, 50Hz, 430V with rupturing capacity 36 KA - 01 No (Incomer) (b) MCCB, 3P, 100 A, 50Hz, 430V with rupturing capacity 25 KA - 01 No (c) MCCB, 3P, 32 A, 50Hz, 415V with rupturing capacity 18 KA - 06 Nos (d) Multifunction electronic digital display meter Cl-1 with programmable CT/PT measuring VI, P, PF, KVAR etc., - 1No. (e) Indicator lamp LED for R, Y, B with MCB - 1set.
S & F GI cable tray of size 75mm x 50mm x 2mm including fixing in wall / floor / column alongwith fasteners / supports complete all as specified and directed.
S & F GI cable tray of size 100mm x 75mm x 2mm including fixing in wall / floor / column alongwith fasteners / supports complete all as specified and directed.
S & F MCCB TP 63Amps, 18 KA, including wall mounted SS enclosure with IP 30 protection complete all as specified and directed.
S & F MCCB TP 40Amps, 18 KA, including wall mounted SS enclosure with IP 30 protection complete all as specified and directed.
S & F MCCB TP 32Amps, 18 KA, including wall mounted SS enclosure with IP 30 protection complete all as specified and directed.
M&L for cable route indicator, consisting of cast iron round shape 200mm dia., 12mm thick with inscription casting as LT cable 1100 volts grade and fixed with hot dipped GI angle iron of size 40mm x 40mm x 6mm thick, 0.8m long with GI nut, bolts, embedded to ground in route of cable with the help of PCC 1:3:6, type C2, complete all as specified and directed
M&L for fabrication and installation of standalone sheet metal enclosure made out of CRCA sheet of 12mm thickness of suitable size supported with angle iron base of 30mm x 30mm x 6mm and 1.2m length for fixing of MCCB 3 Pole 50A, 18 KA breaking capacity complete all as specified and directed.
S & F LED bollard 10W, IP-65, including necessary PCC work, excavation etc., complete all as specified and directed.
Supply & Lay PE / PP DWC pipe of outer diameter 160mm for cable protection alongwith couplers complete all as specified and directed.
Supply & Lay PE / PP DWC pipe of outer diameter 110mm for cable protection alongwith couplers complete all as specified and directed.
Supply & Lay PE / PP DWC pipe of outer diameter 50mm for cable protection alongwith couplers complete all as specified and directed.
Drilling / boring through any type of soil upto the depth as directed / indicated for 500mm outer dia. bored cast-in-situ, vertical pile, duly stabilising the sides by drilling fluids (Auger boring / Direct Mud Circulation boring method), the method of boring will be approved by GE based on site condition before execution of work and disposal of drilled / bored material to a distance exc 50m and n.exc. 100m complete as shown on drawing, all as specified and directed.
Drilling / boring through soft disintegrated rock upto the depth as directed / indicated for 500mm outer dia. bored cast-in-situ, vertical pile, duly stabilising the sides by drilling fluids (Auger boring / Direct Mud Circulation boring method), the method of boring will be approved by GE based on site condition before execution of work and disposal of drilled / bored material to a distance exc 50m and n.exc. 100m complete as shown on drawing, all as specified and directed.
Drilling / boring through hard rock upto the depth as directed / indicated for 500mm outer dia. bored cast-in-situ, vertical pile, duly stabilising the sides by drilling fluids (Auger boring / Direct Mud Circulation boring method), the method of boring will be approved by GE based on site condition before execution of work and disposal of drilled / bored material to a distance exc 50m and n.exc. 100m complete as shown on drawing, all as specified and directed.
Drilling / boring through any type of soil upto the depth as directed / indicated for 600mm outer dia. bored cast-in-situ, vertical pile, duly stabilising the sides by drilling fluids (Auger boring / Direct Mud Circulation boring method), the method of boring will be approved by GE based on site condition before execution of work and disposal of drilled / bored material to a distance exc 50m and n.exc. 100m complete as shown on drawing, all as specified and directed.
Drilling / boring through soft disintegrated rock upto the depth as directed / indicated for 600mm outer dia. bored cast-in-situ, vertical pile, duly stabilising the sides by drilling fluids (Auger boring / Direct Mud Circulation boring method), the method of boring will be approved by GE based on site condition before execution of work and disposal of drilled / bored material to a distance exc 50m and n.exc. 100m complete as shown on drawing, all as specified and directed.
Drilling / boring through hard rock upto the depth as directed / indicated for 600mm outer dia. bored cast-in-situ, vertical pile, duly stabilising the sides by drilling fluids (Auger boring / Direct Mud Circulation boring method), the method of boring will be approved by GE based on site condition before execution of work and disposal of drilled / bored material to a distance exc 50m and n.exc. 100m complete as shown on drawing, all as specified and directed.
Carrying out initial pile load test on 500mm dia. Pile as per IS-2911 Part IV 2013 for 2.50 times the safe design load as per structural drawing including bringing at site all testing equipment, making arrangement for testing and removal of the same after completion of work and submitting the initial pile load test results in quadrauplicate by approved consultancy duly signed by all concerned with site photography complete all as specified and directed.
Carrying out Routine pile load test on 500mm dia. Pile as per IS-2911 Part IV 2013 for 1.50 times the safe design load as per structural drawing including bringing at site all testing equipment, making arrangement for testing and removal of the same after completion of work and submitting the initial pile load test results in quadrauplicate by approved consultancy duly signed by all concerned with site photography complete all as specified and directed.
Carrying out initial pile load test on 600mm dia. Pile as per IS-2911 Part IV 2013 for 2.50 times the safe design load as per structural drawing including bringing at site all testing equipment, making arrangement for testing and removal of the same after completion of work and submitting the initial pile load test results in quadrauplicate by approved consultancy duly signed by all concerned with site photography complete all as specified and directed.
Carrying out Lateral pile load test on 500mm / 600mm dia. Pile as per IS-2911 Part IV 1985 for the safe design load as per structural drawing including bringing at site all testing equipment, making arrangement for testing and removal of the same after completion of work and submitting the initial pile load test results in quadrauplicate by approved consultancy duly signed by all concerned with site photography complete all as specified and directed.
Carrying out Routine pile load test on 600mm dia. Pile as per IS-2911 Part IV 2013 for 1.50 times the safe design load as per structural drawing including bringing at site all testing equipment, making arrangement for testing and removal of the same after completion of work and submitting the initial pile load test results in quadrauplicate by approved consultancy duly signed by all concerned with site photography complete all as specified and directed.
Carrying out Standard penetration test (SPT)on 500mm / 600mm dia. at levels and locations of cast-in-situ bored Piles as per IS-2131 complete all as specified and directed.
Carrying out / Conduction of pile integrity test using low strain dynamic method all as per IS for 500mm dia. piles complete all as specified and directed.
Carrying out / Conduction of pile integrity test using low strain dynamic method all as per IS for 600mm dia. piles complete all as specified and directed. Notes for Sl. Item Nos. 41 to 48 i) The Initial Pile load test and Routine Load test should be performed in the presence of representative of GE and Accepting Officer. Routine load test shall be carried out on working piles only. ii) Working pile execution shall only be carried out after getting clearance from Accepting Officer after review of initial test pile results.
Supply, lay and testing fire alarm cable (Red colur) of size 4 core 1.5sqmm, conforming to BS 7629-1, BS EN 50200 consisting of plain annealed copper conductor to BS EN 60228 class 2 with primary and secondary insulation laid in PVC conduit of size not less than 20mm dia. complete all as specified and directed.
Supply, install, test and commissioning Tower AC units of 3TR capacity inverter type indoor / outdoor unit with copper condenser coil and all accessories i.e., copper tubing, insulation, drain pipe etc., complete with cordless remote unit and inbuilt air ioniser and plasma filters for better filter for air quality with 5 star rating and EER 3.2 of capacity including copper tubing as required for suction and discharge with insulation and clading, flexible drain pipe of length as required at site. The outdor unit shall be mounted on heavy duty factory made mounting stand with anchor fastener, nuts, bolts for fixing on wall at the specified location (suitable height for maintenance) and connecting the indoor-outdoor unit by means of copper tubing including flaring, bending brazing work at site and testing complete with satisfactory cooling results complete all as specified and directed.
Supply and fixing Voltage stabiliser for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 170V to 250V with output voltage stabilised at 230V with accuracy of + 2.5% and of capacity 5 KVA complete all as specified and directed
Supply and fixing Voltage stabiliser for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 170V to 250V with output voltage stabilised at 230V with accuracy of + 2.5% and of capacity 2 KVA complete all as specified and directed
Supply and fix Automatic air release valve 50mm dia., brass type, spring loaded suitable for domestic water with 50mm gun metal stop valve complete all as specified and directed
Supply and Fix LED Bulb 1x09 Watt, 230 V, AC Suitable size complete all as specified and directed.
Supply and fixing MCB DB VTPN 6 way IP-54 made of sheet steel phos phatised, powder painted with copper bus bar 200A, neutral link, earth bar and Din rail 415 Volts with double door with provision for MCCB TPN as incomer and MCB outgoing . Note : MCBs will measured and paid separately
Supply and fixing MCB DB VTPN 8 way IP-54 made of sheet steel phos phatised, powder painted with copper bus bar 200A, neutral link, earth bar and Din rail 415 Volts with double door with provision for MCCB TPN as incomer and MCB outgoing . Note : MCBs will measured and paid separately
Supply and fixing double RJ11 modular telephone outlet/socket jack type with shutter similer to M/S Legrand cat part No. 573627 or equivalent in Anchor/Havells etc., complete all as specified and directed.
Supply and fixing modular TV Co-Axial socket similar to M/s Legrand cat part No. 573625 or equivalent in Anchor / Havells etc., complete all as specified and directed.
Design, supply, install, testing and commissioning of goods lift, suitable for 1000kg capacity, speed 0.5m/sec with single speed motor, 415volts, 3 phase AC 50Hz supply, conforming to IS-14665 and as amended, suitable to serve G+2 floors with AC Variable Voltage & Variable Frequency Drive (VVVF drive) complete with all standard accessories, simplex automatic & manual dual controlled operation with / without attendant, side opening doors with door drive (electric motor driven mechanism), sliding stainless steel doors, automatic rescue device (ARD) system, 3D infrared sensor in full height of door & built in announcing system without hand set (03 Nos, one each in car, machine room & near Ground floor landing door) complete all as specified and directed. Make: JOHNSON / OTIS / KONE / PREMIER LIFTS
Supply, erect, test and commissioning of 12.5m high mast 20 side polygon shaft in two sections of top OAF 150mm and bottom OAF 360mm, thickness -3mm, suitable for 50m/sec wind speed along with head frame, luminaries carriage. Material of construction 50NB ERW Class B- MS pipe, diameter of carriage ring (mm)-450mm (ID), construction, 4 Arm, welded, 23 sections Load carrying capacity of 4 Luminaire 120W LED in symmetrical arrangement, 01 number aviation obstuction light, lightning finial, winch / power tool type / swl of winch, double drum, SWL 350Kg, operation with motor, motor capacity-.075HP, 6 pole, single speed, Grade / construction of wire rope is AISI 316, 7/19 construction, Number of ropes two, continuous diameter 5mm, braeking load capacity-1350kg x 2 and including following accessories: (a) Foundation bolts manufactured from special steel along with nuts, washers, anchor plates and templates, Ts 600/30mm diameter / 850mm long length of foundation bolts and other accessories. (b) The light luminaries shall be 1 x 120W LED flood light-4 Nos. (c) Aviation obstruction LED fitting -1No. (d) Design and casting of suitable shallow foundation with M-20 design mix concrete for high mast considering the safe soil bearing capacity of soil as 10T/sqm at 2m depth with all materials and labour including excavation, rfr and removal of spoil..
Sl Item No.61 Contd... (e) Outdoor feeder pillar with 32A TPN MCB incomer, single dial time switch, 25A TP contactor for the automatic switching of luminaries, power tool control with 2 No. 9A contactors and raise lower push button, incoming 35sqmm and outgoing 16 & 2.5sqmm terminals complete. (f) 04 Nos Earthing complete with Galvanized steel earth plate electrode of size 600x600x6mm thick buried directly in ground with earth pit not less than 2.25m deep below the normal ground level with top edge of plate not less than 1.5m below normal ground level, earth plate surrounded from all sides by 15cm thick and packed layer of charcoal dust and common salt filling in alternate layers and electrode connections by GI earth wire 4mm connected by means of bolts, nuts, check nuts and washers of Galvanized iron or steel all as shown in electrical plate No. 3 of SSR Part-I connected to earthing test point all as specified or indicated including testing on completion and directed. [Note: The unit rate shall be deemed to include for excavation & earth work in any type of soil, PCC (1:3:6) type C1 chamber, RCC 1:2:4, Type B-1 cover 50mm thick reinforced with 6 Nos 8mm dia TMT bars on both ways, MS handle 12mm dia, CI funnel and wire mesh, GI watering pipe 20mm dia medium grade for watering, GI protection pipe light grade 15mm dia, earthing lead upto 7.5m complete all as directed]
a) Design, supply, install, testing and commissioning of factory made microprocessor controlled air cooled variable, refrigerent flow type air conditioning system of capacity not less than 45 TR (15 TRx3 Nos) (02 Operation & 01 for Standby) for Auto control shop bldg to maintain a temperature range 22 degree +/-2 degree Celcius consisting modular type outdoor units equipped with highly efficient full inverter scroll compressors (all compressors will have to be inverter type), special acryl precoated/ blue fin heat exchanger (All metal parts to be suitable for sea port area), low noise condenser fan. The outdoor and indoor units shall be integrated with special super wiring system LCD display into one common wiring circuit from indoor control arrangement including refrigerent gas R410A or equvalent non- CFC type including all structural MS frame work, PCC platform required to complete all as specified and directed. MAKE: VOLTAS / BLUESTAR / LG / CARRIER / DAIKIN AUTO CONTROL SHOP BLDG For first floor and second floor (15 TR x 3 Nos)-01 No.
Sl item No.62 Contd.... b) Ceiling mounted 4 way air discharge cassette type indoor units Capacity of each indoor unit shall not be less than 3.0 TR with compact cooling, having complete accessories including front grill and cord less remote vcontrol unit and multi speed fan motor, dynamically balanced blower and designed for silent operation, including advanced air filters to keep the clean and dust free at 20 micron level. The filter shall have to be synthetic washable media type arranged for convient cleaning and replacement, built-in drain pump, suitable drain pan fabricated out of heavy sheet steel insulated with 6mm expanded polyethene sheet including remote operating arrangements with board LCD display system and including suitable drain pipe connected upto the ground level outside the building through suitable route. Auto control shop First floor- 7 Nos, Auto control shop second floor- 8 Nos. c) Wired remote control unit suitable for central room wise control for all cassette type units installed in all individual rooms together with LCD display and self diagnostic features complete all as specified and directed-04 each d) Refrigerant copper piping insulated with Nitrile Rubber Tubular insulation for various sizes from 9mm to 42mm (outer dia) and 8 to 19mm thick insulation including suitable joints/ branch connectors and distributors for indoor & outdoor units as required at site complete all as specified and directed.
Sl item No.62 Contd.... e) UPVC heavy class drain pipes with all fittings and necessary thermal insulation with 6mm thick Nitrile Rubber tubes for the cassette type units for the size 25 to 40mm outer dia duly fixed to wal floor with suitable MS brackets/ clamps. f) Perforated cable tray, made of 1.0mm thick plain Galvanized steel sheet, for laying of the XPLE cable, sub main wiring, copper tubing etc., including all supports, brackets, clamps, nuts & bolts etc., of sizes 150 to 300mm width and 50mm depth. g) PVC insulated, PVC sheathed cable galvanized steel strip or wire armoured, electric control cables (Heavy duty) with stranded copper conductor, 1100 Volts grade of 2.5 sqmm x 2core, 2.5 sqmm x 4core and 4 sqmm x 4core of required length. h) Design, fabrication, Supply, installation, testing and commissioning control panel in door type suitable for package type air conditioner, made out of 2mm thick MS sheet bduly powder coated suitable size, 3 nphases 4 wire 415 Volt with angle iron frame, cubical type complete, with minimum IP 54 as per IS 13947 protection with PCC foundation (1:2:4) type B2 complete all as specified and directed, suitable for housing and comprising bus bar and switch gears of various capacity as required-1 Job j) Communication/ shield cable of 1sqmm 3core for connecting of AC plants of required length.
a) Design, supply, install, testing and commissioning of factory made microprocessor controlled air cooled variable, refrigerent flow type air conditioning system of capacity not less than 45 TR (15 TRx3 Nos) (02 Operation & 01 for Standby) for Auto control shop Annex bldg to maintain a temperature range 22 degree +/-2 degree Celcius consisting modular type outdoor units equipped with highly efficient full inverter scroll compressors (all compressors will have to be inverter type), special acryl precoated / blue fin heat exchanger (All metal parts to be suitable for sea port area), low noise condensor fan. The outdoor and indoor units shall be integrated with special super wiring system LCD display into one common wiring circuit from indoor control arrangement including refrigerent gas R410A or equvalent non- CFC type including all structural MS frame work, PCC platform required to complete all as specified and as directed. MAKE: VOLTAS / BLUESTAR / LG / CARRIER / DAIKIN AUTO CONTROL SHOP ANNEX BLDG For first floor and second floor (15 TR x 3 Nos)-01 No.
Sl item No.63 Contd.... b) Ceiling mounted 4 way air discharge cassette type indoor units Capacity of each indoor unit shall not be less than 3.0 TR with compact cooling, having complete accessories including front grill and cord less remote vcontrol unit and multi speed fan motor, dynamically balanced blower and designed for silent operation, including advanced air filters to keep the clean and dust free at 20 micron level. The filter shall have to be synthetic washable media type arranged for convient cleaning and replacement, built-in drain pump, suitable drain pan fabricated out of heavy sheet steel insulated with 6mm expanded polyethene sheet including remote operating arrangements with board LCD display system and including suitable drain pipe connected upto the ground level outside the building through suitable route. Auto control shop Annex building First floor- 7 Nos, Auto control shop Annex building second floor- 8 Nos. c) Wired remote control unit suitable for central room wise control for all cassette type units installed in all individual rooms together with LCD display and self diagnostic features complete all as specified and directed-04 each d) Refrigerant copper piping insulated with Nitrile Rubber Tubular insulation for various sizes from 9mm to 42mm (outer dia) and 8 to 19mm thick insulation including suitable joints/ branch connectors and distributors for indoor & outdoor units as required at site complete all as specified and directed.
Sl item No.63 Contd.... e) UPVC heavy class drain pipes with all fittings and necessary thermal insulation with 6mm thick Nitrile Rubber tubes for the cassette type units for the size 25 to 40mm outer dia duly fixed to wal floor with suitable MS brackets/ clamps. f) Perforated cable tray, made of 1.0mm thick plain Galvanized steel sheet, for laying of the XPLE cable, sub main wiring, copper tubing etc., including all supports, brackets, clamps, nuts & bolts etc., of sizes 150 to 300mm width and 50mm depth. g) PVC insulated, PVC sheathed cable galvanized steel strip or wire armoured, electric control cables (Heavy duty) with stranded copper conductor, 1100 Volts grade of 2.5 sqmm x 2core, 2.5 sqmm x 4core and 4 sqmm x 4core of required length. h) Design, fabrication, Supply, installation, testing and commissioning control panel in door type suitable for package type air conditioner, made out of 2mm thick MS sheet bduly powder coated suitable size, 3 nphases 4 wire 415 Volt with angle iron frame, cubical type complete, with minimum IP 54 as per IS 13947 protection with PCC foundation (1:2:4) type B2 complete all as specified and directed, suitable for housing and comprising bus bar and switch gears of various capacity as required-1 Job j) Communication/ shield cable of 1sqmm 3core for connecting of AC plants of required length. Note for Sl item No.62 & 63 The complete design of AC system to be carried by OEM and got approved from Accepting Officer before commencement of work.
P NAIDU (BID ID -3452642)
Jas & Co (BID ID -3452659)
BHARAT MULTITECH INDUSTRIES PVT LTD (BID ID -3451323)
City Constructie Pvt Ltd (BID ID -3457409)
stage.html
html • 0.05 MB
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 0.42 MB
Tender.pdf
Tender Documents • 3.03 MB
WDDrawings.pdf
Additional Documents • 28.25 MB
TDdrawings_.pdf
Additional Documents • 6.96 MB
BOQ_817717.xls
BOQ • 0.30 MB
Download all tender documents and submit your bid