Tender ID
| # | Company | Status |
|---|---|---|
| 1 | Accepted-Technical | Accepted-Technical TECHNICALLY QUALIFIED |
| 2 | Accepted-Technical OLD NO 14 2 NEW NO 20 1 PARTHASARATHY STREET AYANAVARAM CHENNAI 600 023 | CHENNAI | CHENNAI | TAMIL NADU | 600023 | Accepted-Technical TECHNICALLY QUALIFIED |
| 3 | Accepted-Technical | Accepted-Technical TECHNICALLY QUALIFIED |
Tender Value
₹4.2 Cr
EMD Value
₹8.3 L
Closing Date
5 Mar 2026, 5:15 pmClosed
The Dean
ESIC MCH Ashok Pillar Road, KK Nagar Chennai-600078
Annual Repair and Maintenance Electrical Works, inclu Operation Maintenance of Electromechanical Equipment such as Lifts, DG Sets, Firefighting equipment, 11KV / 415V Switchyard Substation, HT/LT Panels, RO Plant etc at ESIC MCH KK Nagar Chennai
2026_ESIC_898411_1
02/EE/PMD/ESIC/TN/KKN/ARM25-26
Open Tender
Electrical Works
Works
365 days
ESIC MCH at KK Nagar Chennai
Please refer Tender documents.
8 documents required · 8 mandatory
₹0
₹8.3 L
20 Apr 2026
13 Feb 2026
6 Mar 2026
13 Feb 2026
5 Mar 2026
13 Feb 2026
Supply of 1.5 sq. mm ISI marked, FRLS PVC insulated, single core copper conductor cable
Supply of 2.5 sq. mm ISI marked, FRLS PVC insulated, single core copper conductor cable
Supply of 4.0 sq. mm ISI marked, FRLS PVC insulated, single core copper conductor cable
Supply of 6.0 sq. mm ISI marked, FRLS PVC insulated, single core copper conductor cable
Supplt of 10 sq. mm ISI marked, FRLS PVC insulated, single core copper conductor cable
Supply of 16 sq. mm ISI marked, FRLS PVC insulated, single core copper conductor cable
Supply of 20 mm dia. ISI marked, PVC conduit
Supply of 25 mm dia. ISI marked, PVC conduit
Supply of 20 mm PVC bends
Supply of 25 mm PVC bends
Supply of 20 mm PVC couplers
Supply of 25 mm PVC couplers
Supply of 20 mm PVC junction box, one way
Supply of 20 mm PVC junction box, two way
Supply of Modular GI box for 2 module
Supply of Modular GI box for 3 module
Supply of Modular GI box for 4 module
Supply of Modular GI box for 6 module
Supply of Modular GI box for 8 module
Supply of Modular GI box for 12 module
Supply of S.P. 5/6 A, one way modular switch, ISI marked
Supply of S.P. 15/16 A, one way modular switch, ISI marked
Supply of 3 pin 5/6 A modular socket outlet, ISI marked
Supply of 6 pin 15/16 A modular socket outlet, ISI marked
Supply of Stepped type Modular Fan regulator (2 module)
Supply of Modular blanking plate
Supply of 6 pin 25 amp modular type socket ISI Marked
Supply of Modular base & cover plate for 1 module
Supply of Modular base & cover plate for 2 module
Supply of Modular base & cover plate for 3 module
Supply of Modular base & cover plate for 4 module
Supply of Modular base & cover plate for 6 module
Supply of Modular base & cover plate for 8 module
Supply of Modular base & cover plate for 12 module
Supply of S.P. 5/6 A, one way switch, piano type ISI marked
Supply of S.P. 5/6 A, two way switch, piano type ISI marked
Supply of S.P. 15/16 A, one way switch, piano type ISI marked
Supply of 3 pin 5/6 A socket outlet, piano type ISI marked
Supply of 6 pin 15/16 & 5/6 A socket outlet, piano type ISI marked
Supply of Bell push piano type
Supply of Call bell/ buzzer, single phase
Supply of PVC Batten/ Angle Holder
Supply of 32 Amps TPN Switch
Supply of 63 Amps TPN Switch
Supply of 6 amps. to 32 amps. ratings , SP MCB, “C” curve, 10 KA breaking capacity
Supply of 6 amps. to 32 amps. ratings , DP MCB, “C” curve, 10 KA breaking capacity
Supply of 63 amps., 4 pole isolator
Supply of 100 amps., 4 pole isolator
20 amps, SPN, Industrial type socket outlet, with plug top and metal chained cover in sheet steel enclosure
Supply of 6 way SPN Double door MCB DB
Supply of 12 way SPN Double door MCB DB
Supply of 16 way SPN Double door MCB DB
Supply of 4 way (4+12) TPN MCB DB double door horizontal type
Supply of 6 way (4+18) TPN MCB DB double door horizontal type
Supply of Brass compression gland for (28 mm) 3½ X 25 sq. mm 1.1 KV grade cable
Supply of Brass compression gland for (32 mm) 3½ X 35 sq. mm1.1 KV grade cable
Supply of Brass compression gland for (35 mm) 3½ X 50 sq. mm1.1 KV grade cable
Supply of Brass compression gland for (38 mm) 3½ X 70 sq mm1.1 KV grade cable
Supply of Brass compression gland for (45 mm) 3½ X 95 sq. mm 1.1 KV grade cable
Supply of Brass compression gland for (45mm) 3½ X 120 sq.mm 1.1 KV grade cable
Supply of Brass compression gland for (50mm) 3½ X 150 sq.mm 1.1 KV grade cable
Supply of Brass compression gland for (57mm) 3½ X 185 sq.mm 1.1 KV grade cable
Supply of Brass compression gland for (62mm) 3½ X 240 sq.mm 1.1 KV grade cable
Supply of Brass compression gland for (82mm) 3½ X 400 sq.mm 1.1 KV grade cable
Supply of Aluminium lugs for 6 sq. mm cable
Supply of Aluminium lugs for 10 sq. mm cable
Supply of Aluminium lugs for 16 sq. mm cable
Supply of Aluminium lugs for 25 sq. mm cable
Supply of Aluminium lugs for 35 sq. mm cable
Supply of Aluminium lugs for 50 sq. mm cable
Supply of Aluminium lugs for 70 sq. mm cable
Supply of Aluminium lugs for 95 sq. mm cable
Supply of Aluminium lugs for 120 sq. mm cable
Supply of Aluminium lugs for 150 sq. mm cable
Supply of Aluminium lugs for 185 sq. mm cable
Supply of Aluminium lugs for 400 sq. mm cable
Supply of Al. Alloy/ cadmium plated iron screws, 20 mm
Supply of Iron screws, 35 mm X 6 mm
Supply of Iron screws, 40 mm X 6 mm
Supply of Steel fastener 6 mm X 75 mm
Supply of Steel fastener 8 mm X 75 mm
Supply of Rubber/ PVC bushes
Supply of PVC sleeve
Supply of Charcoal
Supply of Salt
Supply of Cotton waste, cleaning cloth etc.
Supply of Basic Price for 1200 mm sweep BLDC Ceiling fan i/c all accessories/fittings/ supports etc.
Supply of 6 amps. to 32 amps. ratings , TP MCB, “C” curve, 10 KA breaking capacity
Supply of 6 amps. to 32 amps. ratings , TPN MCB, “C” curve, 10 KA breaking capacity
Supplying of 18 Watt Round type LED Recessed/surface Down lighter (Round / square/ Rectangular) COB Type of following body material and construction as per IS : 10322 with driver as per the requirement with Driver efficiency >85%, Operating voltage AC 140-270 Volt, freq 50/60 hz, Operating temp range -15 deg to 40 deg centigrade, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10% , P. F.≥0.95, IP20, CRI >80 , UGR (Unified Glare Rating) < 19, Flicker free (flicker should be below 5 %), life time (LED,Driver & electrical circuitary), life time of minimum 50000 Burning Hours with , 70% of initial Lumen maintained till life ends , CCT 3000°K / 4000°K / 5700°K /6000°K/6500°K (As per ANSI Bin), SDCM(Standard Deviation Color Matching)LED Down lighter (COB Type) (System lumen efficacy ≥120 lm/Watt )Make: Havells/Philips/Wipro/Crompton
Supplying of 30 Watt SQUARE /STRIP type LED Recessed/surface Down lighter (Round / square/ Rectangular) COB Type of following body material and construction as per IS : 10322 with driver as per the requirement with Driver efficiency >85%, Operating voltage AC 140-270 Volt, freq 50/60 hz, Operating temp range -15 deg to 40 deg centigrade, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10% , P. F.≥0.95, IP20, CRI >80 , UGR (Unified Glare Rating) < 19, Flicker free (flicker should be below 5 %), life time (LED,Driver & electrical circuitary), life time of minimum 50000 Burning Hours with , 70% of initial Lumen maintained till life ends , CCT 3000°K / 4000°K / 5700°K /6000°K/6500°K (As per ANSI Bin), SDCM(Standard Deviation Color Matching)LED Down lighter (COB Type) (System lumen efficacy ≥120 lm/Watt )Make: Havells/Philips/Wipro/Crompton
Supplying of 36W Panel light 2x2 ft., of following body material and construction as per IS : 10322 with driver as per the requirement with Driver efficiency >85%, Operating voltage AC 140-270 Volt, freq 50/60 hz, Operating temp range -15 deg to 40 deg centigrade, internal surge protection of 2.5 KV with Short & Open circuit protection, THD < 10% , P. F.≥0.95, IP20, CRI >80, UGR (Unified Glare Rating) < 19, Flicker free, (flicker should be 115 DELHI SCHEDULE OF RATES (E&M) Volume-II 2025below 5 %), life time (LED,Driver & electrical circuitary), of minimum 50000 Burning Hours with, 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K / 5700°K /6000°K / 6500°K (As per ANSI Bin), SDCM(Standard Deviation Color Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard and trade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. complete in all respect i/c connections with 1.5 sq mm FRLS, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy 120 <135 lm/Watt lm/Watt output . LM79 & LM80 Test report from NABL lab for all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). Powder coated die cast /Extruded aluminium Body (Thickness > 1.20 mm) LED Panel light 2x2 ft. (System lumen efficacy ≥120 <135 lm/Watt )
Supplying of 18- 22 watt LED surface mounted Batten light of following body material and construction as per IS : 10322 with driver (Replaceable) as per the requirement with Driver efficiency >85% ,Operating voltage AC 140-270 Volt, freq 50/60 hz, Operating temp range -15 deg to 40 deg centigrade, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10% , P. F.≥0.95, IP20, CRI >80, Flicker free, (flicker should be below 5 %), life time (LED,Driver & electrical circuitary), of minimum 50000 Burning Hours with , 70% of initial Lumen maintained till life ends, CCT 3000°K / 4000°K / 5700°K /6000°K/6500°K (As per ANSI Bin), SDCM(Standard Deviation Color Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard and trade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. complete in all respect i/c connections with 1.5 sq mm FRLS, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥120 <135 lm/Watt . LM79 & LM80 Test report from NABL lab for all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement.(Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). CRCA Sheet Body (Thickness > 0.50 mm) LED Batten light (System lumen efficacy ≥105 <120 lm/Watt) Make:Havells/Philips/Crompton/Wipro
Supply of LED Street light fixture 50 watt, powder coated pressure die cast aluminum body (System lumen efficacy >135 lm/Watt) Supplying, installation, Testing & Commissioning of 50 watt Street light LED fixture, powder coated pressure die cast aluminum body with built in or separate driver as per the requirement with Driver efficiency >85%, Input voltage: 140-270 Volt AC, freq 50/60 hz, Operating temp range -15 deg to 50 deg centigrade, internal surge protection of 5 KV L,N,E as per IEC 61000-45, Driver efficiency >85%,THD < 10% as per IEC 61000-3-2 , P. F.≥0.95, IP66,IK-10, CRI >80 , under voltage and over voltage protection,EMIEMC as per CISPR-15, lenses for beam angle as per IESNA type I/II/III as per the width of the road and the project requirement., suitable to fit in up to 65mm dia pipe, life time (LED,Driver & electrical circuitry) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report , CCT 3000°K / 4000°K / 5700°K /6000°K/6500°K (As per ANSI Bin) , SDCM(Standard Deviation Color Matching) <5, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard omplete in all respect i/c connections with 1.5 sq mm FRLS, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy >135 lm/Watt output . LM79 & LM80 Test report from NABL lab for all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminum housing such that LED junction temperature shall not rise above 90°C).
Supply of LED Flood Light 100 watt, powder coated pressure die cast aluminium (System lumen efficacy ≥120 and <135 lm/Watt) Supplying of 150 watt Flood Light, powder coated pressure die cast aluminium body with built in or separate driver as per the requirement with Driver efficiency >85%, Input voltage: Input voltage: 140-270 Volt AC, freq 50/60 hz, Operating temp range -15 deg to 50 deg centigrade, internal surge protection of 5 KV L,N,E as per IEC 61000-4-5, Driver efficiency >85%,THD < 10% as per IEC 61000-3-2 , P. F.≥0.95, IP-66,IK-10, CRI >80 , under voltage and over voltage protection,EMI-EMC as per CISPR-15, lenses for beam angle 30 deg-120deg as per the application and the project requirementdeg, suitable tilt able fitting, life time (LED,Driver & electrical circuitary) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report , 3000°K / 4000°K / 5700°K /6000°K/6500°K (As per ANSI Bin) , SDCM(Standard Deviation Color Matching) <5, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect i/c connections with 1.5 sq mm FRLS, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥120 and <135 lm/Watt output . LM79 & LM80 Test report from NABL lab for all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C).
LED Flood Light 150 watt, powder coated pressure die cast aluminium (System lumen efficacy ≥120 and <135 lm/Watt) Supplying of 150 watt Flood Light, powder coated pressure die cast aluminium body with built in or separate driver as per the requirement with Driver efficiency >85%, Input voltage: Input voltage: 140-270 Volt AC, freq 50/60 hz, Operating temp range -15 deg to 50 deg centigrade, internal surge protection of 5 KV L,N,E as per IEC 61000-4-5, Driver efficiency >85%,THD < 10% as per IEC 61000-3-2 , P. F.≥0.95, IP-66,IK-10, CRI >80 , under voltage and over voltage protection,EMI-EMC as per CISPR-15, lenses for beam angle 30 deg-120deg as per the application and the project requirementdeg, suitable tilt able fitting, life time (LED,Driver & electrical circuitary) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report , CCT 3000°K / 4000°K / 5700°K /6000°K/6500°K (As per ANSI Bin) , SDCM(Standard Deviation Color Matching) <5, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect i/c connections with 1.5 sq mm FRLS, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥120 and <135 lm/Watt output . LM79 & LM80 Test report from NABL lab for all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C).
Supply of FLUORESCENT TUBULAR LAMPS WITH ISI MARK Cool Day Light 4 Ft. 40 Watts
20W 4 Feet LED Fitting with LED
Supply of 4' 18W Crystal Glass LED Tube Light
Supply of 7W / 9W LED Bulb
Supply of 15W LED Bulb
Supply of 63A 3 Phase 4 Pole Contactor
Supply of POLYSTER FILLED COPPER CHOKE 250V/50HZ GRADE SUITABLE FOR 36/40W Electronic Ballast for Fluorescent Tube (Higher End)
Supply of Fan Clamp (Dia 12mm) with 6mm MS Side Plates & 45cm Cross Arm
Supply of Stepped type Modular Fan regulator (2 module)
Supply of EXHAUST FANS AC Exhaust Fan 300mm (12") Sweep (Heavy Duty)
Supply of AC Exhaust Fan 450mm (18") Sweep (Heavy Duty)
Supply of WALL MOUNTING FAN 400mm Sweep
Supply of 16 Amps Porcelain Fuse Unit (500V)
Supply of 32 Amps Porcelain Fuse Unit (500V)
Supply of SURFACE MOUNTING BOXES (PLASTIC) Surface Box - 1/2 Module Higher End
Supply of SURFACE MOUNTING BOXES (PLASTIC) Surface Box - 3 Module Higher End
Supply of SURFACE MOUNTING BOXES (PLASTIC) Surface Box - 4 Module Higher End
Supply of SURFACE MOUNTING BOXES (PLASTIC) Surface Box - 6 Module Higher End
Supply of SURFACE MOUNTING BOXES (PLASTIC) Surface Box - 8 Module Surface Box - 8 (2 row x 4) Module
Supply of SURFACE MOUNTING BOXES (PLASTIC) Metal Surface Box - 12/16 (2 row x 6) Module Higher End
Supply of PLUG AND SOCKETS 5 Amps 3 Pin Top
Supply of PLUG AND SOCKETS 15 Amps 3 Pin Top
Supply of PLUG AND SOCKETS 20Amps MC Plug with 3 Pin Top
2 core 10 sqmm PVC armoured UG cable (LT 1.1KV PVC Alu.)
2 core 25sqmm PVC armoured UG cable (LT 1.1KV PVC Alu.)
3.5 core 25sqmm PVC armoured UG cable (LT 1.1KV PVC Alu.)
3.5 core 35 sqmm PVC armoured UG cable (LT 1.1KV PVC Alu.)
3.5 core 50 sqmm PVC armoured UG cable (LT 1.1KV PVC Alu.)
3.5 core 70 sqmm PVC armoured UG cable (LT 1.1KV PVC Alu.)
3.5 core 95 sq.mm. PVC Armoured UG Cable (LT 1.1KV PVC Alu.)
3.5 core 120 sqmm PVC armoured UG cable (LT 1.1KV PVC Alu.)
3.5 core 150 sq.mm. PVC Armoured UG Cable Metre (LT 1.1KV PVC Alu.)
3.5 core 185 sqmm PVC armoured UG cable (LT 1.1KV PVC Alu.)
3.5 core 400 sqmm PVC armoured UG cable (LT 1.1KV PVC Alu.)
4 core 6sq.mm. PVC Armoured UG Cable (LT 1.1KV PVC Alu.)
4 core 10sq.mm. PVC Armoured UG Cable (LT 1.1KV PVC Alu.)
4 core 16 sq.mm. PVC Armoured UG Cable (LT 1.1KV PVC Alu.)
Supply of Cable Glands suitable for 2 core 4 Sqmm UG cable
Supply of Cable Glands suitable for 2 core 6 Sqmm UG cable
Supply of Cable Glands suitable for 2 core 10 Sqmm UG cable
Supply of Cable Glands suitable for 2 core 16 Sqmm UG cable
Supply of FUSE WIRE ( Copper ) -5 Amps fuse wire
Supply of NEUTRAL LINK 15 Amps- 4 way neutral link
Supply of NEUTRAL LINK 15 Amps- 6 way neutral link
Supply of NEUTRAL LINK 15 Amps- 8 way neutral link
Supply of Synthetic Moulded Compound Box for Street Light
Supply of PVC Rigid Bend 32mm (1 1/4")
Supply of PVC Rigid Bend 40mm (1 1/2")
Supply of Junction Boxes 1, 2, 3 & 4 way 25mm (1")
Supply of Junction Boxes 1, 2, 3 & 4 way 32mm (1 1/4")
Supply of Junction Boxes 1, 2, 3 & 4 way 38mm (1 1/2")
Supply of P.V.C.Hylem sheets - Hylem sheet 3mm thick
Supply of Insulation tape P.V.C - Insulation tape 19mm
Supply of Insulation tape P.V.C - Empire Tape (19mm)
Supply of Teak wood box concealed type 12" X 8" X 3"
Supply of Teak wood box concealed type 8" X 6" X 3"
Supply of Teak wood box concealed type 6" X 4" X 3"
Supply of Teak wood box concealed type 4" X 4" X 3"
Supply of MCB 100A Four Pole MCB
Supply of Sheet Steel Enclosure for MCB's 2 Pole Legrand/Equivalent
Supply of Sheet Steel Enclosure for MCB's 4 Pole Legrand/Equivalent
63 A, rating, 4 pole RCCB, 30mA
Supply of ELCB (FOUR POLE) 63 Amps 30 MA
Supply of HT cable- 185 sq.mm. 3 core HT XLPE 11KV ( E)
Supply of HT cable- 300 sq.mm. 3 core HT XLPE 11KV ( E)
Supply of 2m x 1m Rubber Mat suitable for 11 KV installation confirming to IS
Supply of SAFETY ACCESSORIES Hand Gloves 11KV Grade
Supply of SAFETY ACCESSORIES Earth Discharge Rod
Supply and installation of 5 KVA capacity Automatic Voltage Stabilizer with time delay relay
Supply and fixing of MS stand for fixing outdoor unit
Supply of 7.50 Metre Length Single Bracket Pole with Base Plate (250 x 250 x 6mm) 114.30mm OD x 5.40mm Thick x 4500mm Length, 88.90mm OD x 4.85mm Thick x 1500mm Length, 76.1mm OD x 3.25mm Thick x 1500mm Length
Supply of 7.50 Metre Length Double Bracket Pole with Base Plate (250 x 250 x 6mm) 114.30mm OD x 5.40mm Thick x 4500mm Length, 88.90mm OD x 4.85mm Thick x 1500mm Length, 76.10mm OD x 3.25mm Thick x 1500mm Length
Supply of Nylon Rope for Bore-well
Supply and fixing 400mm High speed pedestal fan Oscilating
Supply and Fixing of 2 Pin/4 Pin, Round/squared FPL 18 W LED PL bulb/lamp suitable for existing panel light Make: Philips/Wipro & its equivalent
Supply of ISI marked (IS:4159) marked copper sheathed, nickel plated, mineral filled heating element including making connection testing etc as required 2.0 KW
Supply of stem type ISI marked (IS 3017 / 85) snap action adjustable 11'/7'thermostat water heater including making connection testing etc. as required.
Supply of 3 Core 2.5 Sqmm with ISI marked Flat Copper cable of ISI for Submersible Motors confirming to IS:694:1990.Makes:Finolex/RRKabel/Polycab/Havells/KEI/ Gloster/ Goldmedal / GM/ Finecab/ Million/ APAR(Anushakthi)
Supply of 3 Core 4 Sqmm with ISI marked Flat Copper cable of ISI for Submersible Motors confirming to IS: 694:1990.Makes:Finolex/RRKabel/Polycab/Havells/KEI/ Gloster/ Goldmedal / GM/ Finecab/ Million/ APAR(Anushakthi)
Supply of compressor for 1.0/1.5 TR Air conditioner
Supply of compressor for 2.0 TR Air conditioner
Supplying and fixing of following sizes of steel conduit aJong with accessories in surface/recess including painting in case of surface conduit or cutting the wali and making good the same in case of recessed conduit as required. 20 mm
Supplying and fixing of following sizes of steel conduit aJong with accessories in surface/recess including painting in case of surface conduit or cutting the wali and making good the same in case of recessed conduit as required. 25 mm
Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required. 20 mm
Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required. 25 mm
Painting of ceiling fan in installed position with one or more coats of spray painting with synthetic enamel paint of approved brand and manufacture to give an even shade, including cleaning of surface with detergent etc. as required.
Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required. 100 A,30KA,FPMCCB
Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required. 200 A,36KA,FPMCCB
Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required.250 A,36KA,FPMCCB
Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required. 400 A, 50KA, FPMCCB
Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required. 630 A, 50KA, FPMCCB
Supplying and fixing of following ways surface/recess mounting, vertical type, 415 V, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200A tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCBs and incomer) as required. (Note : Vertical type MCB TPDB is normally used where 3 phase outlets are required.) 4 way (4+12), Double door
Supplying and fixing of following ways surface/recess mounting, vertical type, 415 V, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200A tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCBs and incomer) as required. (Note : Vertical type MCB TPDB is normally used where 3 phase outlets are required.)8 way (4 + 24), Double door
Providing and fixing M.V. danger notice plate of 200mmx150m made of mild steel atleast 2mm thick and vitreous enamelled white on both sides and with inscription in single red cololur on front side as required
Providing and fixing H.T. danger notice plate of 250mmx200m made of mild steel atleast 2mm thick and vitreous enamelled white on both sides and with inscription in single red coolur on front side as required
Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray (Galvanisation thickness not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required. 150 mm width X 50 mm depth X 1.6 mm thickness
Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray (Galvanisation thickness not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required. 300 mm width X 50 mm depth X 1.6 mm thickness
Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray "bends" (galvanisation not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required. 150 mm width X 50 mm depth X 1.6 mm thickness
Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray "bends" (galvanisation not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required. 300 mm width X 50 mm depth X 1.6 mm thickness
Earthing with GI earth pipe 4.5mtr long, 40mm dia inclduing accessories and providing masonary enclosure with cover plate having locking arrangements and water pipe arrangements etc. with charcoal and salt as required
Earthing with G.I. earth plate 600mmX600mmX6mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7metre long etc. with charcoal/coke and salt as required.
Earthing with copper earth plate 600mm X 600mm X 3mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 meter long etc. with charcoal/coke and salt as required
Providing and fixing 25mmX 5mm copper strip on surface or in recess for connections etc. as required.
Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required.
Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing as required.
Providing and fixing 4.00 mm dia copper wire on surface or in recess for loop earthing as required.
Laying one no PVC insulated and pvc sheathed/XLPE power cable of 1.1KV grade of follwing size direct in ground including excavation, sand cushioning, protective covering and refilling etc- upto 35 sq.mm
Laying one no PVC insulated and pvc sheathed/XLPE power cable of 1.1KV gradeof follwing size direct in ground including excavation, sand cushioning, protective covering and refilling etc - Above 35sqmm and upto 95Sqmm
Laying one no PVC insulated and pvc sheathed/XLPE power cable of 1.1KV gradeof follwing size direct in ground including excavation, sand cushioning, protective covering and refilling etc- Above 95sqmm and upto 185Sqmm
Laying one no PVC insulated and pvc sheathed/XLPE power cable of 1.1KV grade of follwing size direct in ground including excavation, sand cushioning, protective covering and refilling etc - Above 185sqmm and upto 400Sqmm
Laying and fixing of one number PVC insulated and PVC sheathed/XLPE power cable of 1.1 KV grade of following size on wall surface as required. Upto 35 sq.mm (clamped with 1mm thick saddle)
Laying and fixing of one number PVC insulated and PVC sheathed/XLPE power cable of 1.1KV grade of following size on wall surface as required. Above 35 sq.mm and upto 95 sq.mm (clamped with 25x3mm MS flat clamp)
Laying and fixing of one number PVC insulated and PVC sheathed/XLPE power cable of 1.1KV grade of following size on wall surface as required. Above 95sq. mm and upto 185 sq. mm (clamped with 25/40x3mm MS flat clamp)
Laying and fixing of one number PVC insulated and PVC sheathed/XLPE power cable of 1.1 KV grade of following size on wall surface as required. Above 185 sq. mm and upto 400 sq. mm (clamped with 40x3mm MS flat clamp)
Laying and fixing of one number PVC insulated and PVC sheathed/XLPE power cable of 1.1KV grade of following size on cable tray as required. Upto 35 sq.mm(clamped with 1mm thick saddle)
Laying and fixing of one number PVC insulated and PVC sheathed/XLPE power cable of 1.1KV grade of following size on cable tray as required. Above 95 sq. mm and upto 185 sq. mm (clamped with 25/40x3mm MS flat clamp)
Laying and fixing of one number PVC insulated and PVC sheathed/XLPE power cable of 1.1 KV grade of following size on wall surface as required. Above 185 sq. mm and upto 400 sq. mm (clamped with 40x3mm MS flat clamp)
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 11 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required. -Above 120 sq. mm and upto 400 sq. mm
Supplying and making end termination with brass compression gland and alumunium lugs for following sizes of PVC insulated and PVC sheathed/ XLPE alumunium conductor cable of 1.1 KV grade as required- 2x 10 sqmm
Supplying and making end termination with brass compression gland and alumunium lugs for following sizes of PVC insulated and PVC sheathed/ XLPE alumunium conductor cable of 1.1 KV grade as required - 2x16 sqmm
Supplying and making end termination with brass compression gland and alumunium lugs for following sizes of PVC insulated and PVC sheathed/ XLPE alumunium conductor cable of 1.1 KV grade as required - 3.5x25 Sqmm
Supplying and making end termination with brass compression gland and alumunium lugs for following sizes of PVC insulated and PVC sheathed/ XLPE alumunium conductor cable of 1.1 KV grade as required - 3½ X 35 sq. mm (32mm)
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. 3½ X 50 sq.mm (35mm)
Supplying and making end termination with brass compression gland and alumunium lugs for following size of PVC insulated and PVC sheathed/XLPE alumunium conductor cable of 1.1 KV grade as required- 3½ X 70 sq. mm (38mm)
Supplying and making end termination with brass compression gland and alumunium lugs for following sizes of PVC insulated and PVC sheathed/XLPE alumunium conductor cable of 1.1 KV grade as required- 3½ X 185 sq. mm (57mm)
Supplying and making end termination with brass compression gland and alumunium lugs for following sizes of PVC insulated and PVC sheathed/XLPE alumunium conductor cable of 1.1 KV grade as required- 3½ X 400 sq. mm (82mm)
supplying and making indoor cable end termination with heat shrinkable jointing kit complete with all accessories including lugs suitable for following size of 3 core, XLPE aluminium conductor cable of 11 KV grade as required: 300 sq. mm
Supplying and making straight through joint with heat shrinkable kit including ferrules and other jointing materials for following size of PVC insulated and PVC sheathed/XLPE aluminium conductor cable of 1.1 KV grade as required. 3½ X 25 sq. mm
Supplying and making straight through joint with heat shrinkable kit including ferrules and other jointing materials for following size of PVC insulated and PVC sheathed/XLPE aluminium conductor cable of 1.1 KV grade as required. 3½ X 35 sq. mm
Supplying and making straight through joint with heat shrinkable kit including ferrules and other jointing materials for following size of PVC insulated and PVC sheathed/XLPE aluminium conductor cable of 1.1 KV grade as required. 3½ X 50 sq. mm
Supplying and making straight through joint with heat shrinkable kit including ferrules and other jointing materials for following size of PVC insulated and PVC sheathed/XLPE aluminium conductor cable of 1.1 KV grade as required. 3½ X 70 sq. mm
Supplying and making straight through joint with heat shrinkable kit including ferrules and other jointing materials for following size of PVC insulated and PVC sheathed/XLPE aluminium conductor cable of 1.1 KV grade as required. 3½ X 95 sq. mm
Supplying and making straight through joint with heat shrinkable kit including ferrules and other jointing materials for following size of PVC insulated and PVC sheathed/XLPE aluminium conductor cable of 1.1 KV grade as required. 3½ X 120 sq. mm
Supplying and making straight through joint with heat shrinkable kit including ferrules and other jointing materials for following size of PVC insulated and PVC sheathed/XLPE aluminium conductor cable of 1.1 KV grade as required. 3½ X 150 sq. mm
Supplying and making straight through joint with heat shrinkable kit including ferrules and other jointing materials for following size of PVC insulated and PVC sheathed/XLPE aluminium conductor cable of 1.1 KV grade as required. 3½ X 185 sq. mm
Supplying and making straight through joint with heat shrinkable kit including ferrules and other jointing materials for following size of PVC insulated and PVC sheathed/XLPE aluminium conductor cable of 1.1 KV grade as required. 3½ X 240 sq. mm
Supplying and making straight through joint with heat shrinkable kit including ferrules and other jointing materials for following size of PVC insulated and PVC sheathed/XLPE aluminium conductor cable of 1.1 KV grade as required. 3½ X 400 sq. mm
Supplying and making straight through cable jointing with heat shrinkable jointing kit complete with all accessories including ferrules suitable for following size of 3 core, XLPE aluminium conductor cable of 11 kV grade as required.300 sq. mm
Supplying, fixing, testing and commissioning of following valves, gauges and strainers for condenser water circulation as per specifications.200 mm dia BUTTERFLY VALVE (MANUAL) without insulation with CI body SS disc nitrile sheet & O-ring & PN 16 pressure rating as specified. Make Advance/Honeywell/Audco
Supplying, fixing, testing and commissioning of following valves, strainers, gauges in the chilled water plumbing duly insulated to the same specifications as the connected piping and adequately supported as per specifications.150 mm dia BUTTERFLY VALVE With insulation (MANUAL) with CI body SS Disc, Nitrile Rubber Seal & O-Ring PN 16 pressure rating for chilled water/hot eater circulation as specified Make Advance/Honeywell/Audco
Supply and fixing of of D.O.L Starter 415V, 3 phase, 50Hz..enclosed with no volt coil and overload protection with necessary materials, etc., complete suitable for up to 3 HP
Supply and fixing of of D.O.L Starter 415V, 3 phase, 50Hz..enclosed with no volt coil and overload protection with necessary materials, etc., complete suitable from 5 to 7.5 HP
Supply & Fixing of Star-Delta Starter 415V, 3 phase, 50Hz.. enclosed with no volt coil, overload protection and single phase preventor , etc., complete suitable for 12.50 to 15HP.
Rewinding of ceiling fan motor (starting and running winding) including all necessary material. The motor is to be wound taking no. of coils, turns and pitch as it was originally wound with required size super enameled wire with 'E' class insulation material and making connections etc. as required. 900/1200 mm sweep
Charges for oiling, greasing, overhauling of ceilingfan, table fan, pedestal fan irrespective to the size of an including removing, refixing of fan from site and testing etc. as required
Providing and Replacement of ball bearing of ceiling/exhaust fan as required. (NBC/ SKF)
Providing and Replacement of Gun metal bush ofceiling/ exhaust/cooler fan/ as required.
Spray painting of ceiling fan of size 900/1200/ 1400 mm with two coats of white/ brown enameled paint after cleaning with sandpaper. Filling etc. as required
Rewinding of 300/ 380 mm sweep Heavy-duty Exhaust fan motor including all necessary material, The motor is to be wound taking no. of coils, turns and pitch as it was originally wound with required size super enameled wire with 'E' class insulation material and making connections etc. as required.
Rewinding of 450 mm sweep mm Heavy-duty Exhaust fan motor including all necessary material, The motor is to be wound taking no. of coils, turns and pitch as it was originally wound with required size super enameled wire with 'E' class insulation material and making connections etc. as required.
Rewinding of 400 mm table fan/pedestal fan motor including all necessary material, the motor is to be wound taking no. of coils, turns and pitch as it was originally wound with required size super enameledwire with 'E' class insulation material and making connections etc. as required
Rewinding of 3 HP three phase motor of 1400 to 2800 RPM including all necessary material and of the same characteristics as original with required size of super enameled wire 'E' class insulation material and testing etc. as required make it in perfect working condition.
Rewinding of 5 HP three phase motor of 1400 to 2800 RPM including all necessary material and of the same characteristics as original with required size of super enameled wire 'E' class insulation material and testing etc. as required make it in perfect working condition.
Rewinding of 7.5 HP three phase motor of 1400 to 2800 RPM including all necessary material and of the same characteristics as original with required size of super enameled wire 'E' class insulation material and testing etc. as required make it in perfect working condition.
Rewinding of 10 HP three phase motor of 1400 to 2800 RPM including all necessary material and of the same characteristics as original with required size of super enameled wire 'E' class insulation material and testing etc. as required make it in perfect working condition.
Rewinding of 12.5 HP three phase motor of 1400 to 2800 RPM including all necessary material and of the same characteristics as original with required size of super enameled wire 'E' class insulation material and testing etc. as required make it in perfect working condition.
Rewinding of 15 HP three phase motor of 1400 to 2800 RPM including all necessary material and of the same characteristics as original with required size of super enameled wire 'E' class insulation material and testing etc. as required make it in perfect working condition.
Supply and charging of fresh refrigerant and testing of performance of 1 TR Window/ Split A.C capacity including capillary and strainer/ filter.
Supply and charging of fresh refrigerant and testing of performance of 1.5 TR Window/ Split A.C capacity including capillary and strainer/ filter.
Supply and charging of fresh refrigerant and testing of performance of 2.0 TR Window/ Split A.C capacity including capillary and strainer/ filter.
Supply and fixing of 230V/ 275V, 50Hz rating Starting capacitor 20-60 micro farad IN Spilt AC
Supply and fixing of 230V/ 275V, 50Hz rating Running capacitor 2.5/3.15/4.0/6.0 micro farad
Supply and fixing of 230V/ 275V, 50Hz rating Running capacitor 8.0 micro farad
Supply and fixing of 230V/ 275V, 50Hz rating Running capacitor 10.0 to 15 micro farad
Supply and fixing of 230V/ 275V, 50Hz rating Running capacitor 36 to 50 micro farad
Supply, Fabrication of 1set MS bracket suitable for fixing outdoor unit of split AC unit.
Supply and laying of 5/8” and 3/8” copper pipe (Extra beyond 3 metres supplied with AC unit)
Supply and fixing of MS stand for fixing outdoor unit
Supply and filling of of R32/ R410a Refrigerant Gas
Supply and fixing of Copper Refrigerant Piping of 7/8” dia including insulation
Providing of 2 runs of Copper tubes for suction and liquid between indoor and outdoor unit for Split/Cassette Air- Conditioner including foaming etc., complete. 1/2" x 1/4"
Providing of 2 runs of Copper tubes for suction and liquid between indoor and outdoor unit for Split/Cassette Air- Conditioner including foaming etc., complete. 5/8" x 1/4"
Providing 2 runs of Copper tubes for suction and liquid between indoor and outdoor unit for Split/Cassette Air- Conditioner including foaming etc., complete. 7/8" x 1/2"
Multi speed Fan Motor suitable for 1.0 / 1.5 / 2.0 Ton Window A.C. Unit
Air filter suitable for1/ 1.50/2.0 Ton Split A.C. Unit P.V.C. / NYLON.
Fan blade for 1.0 / 1.5/2.0 Ton A.C. Machine
Repairs and Installation of existing PCB in 1.0 / 1.5 / 2.0 Ton Split A.C. Unit
Supply and Fixing of Split Ac unit 5/8 & 3/8 valve
Supply and fixing of water drain pipe line (1” PVC Pipe)
Supply and providing of pipeline nitrle rubber insulation for Refrigerant and drain pipe lines
Replacement of overload protection of A.C./ Water cooler as required
Replacement of thermostat of A.C./ Water cooler/fridge as required.
Three phase openwell ISI Marked submersible pumpset of 7.5 H.P. capacity suitable for operation on 415V(+-10%), 3- phase AC supply complete as required.
Supply and Transportation of 10 HP Three phase open well ISI submersible motor pumpset confirms to IS 14220: 1994.
Providing, fixing, testing & commissioning of 15mm dia quartzoid bulb type sprinklers of rating 68 0C with required accessories for Pendent Sprinkler/Upright Sprinkler
Providing Pressure testing of entire system with Nitrogen and vacuuming nitrogen for all indoor and outdoor units. The pressure testing shall be done as per OEM recommendation.
Supply and fixing of 12V 18 AH SMF battery with 3 years warranty, including wire leads, connections etc complete.Makes: Quanta / Racket / Exide & equivalent
Supply and fixing of 12V 9 AH SMF battery with 3 years warranty, including wire leads, connections etc, complete.Makes: Quanta / Racket / Exide & equivalent
Supply and fixing of 12V 65 AH SMF battery with 3 years warranty, including wire leads, connections etc complete.Makes: Quanta / Racket / Exide & equivalent
Supply and fixing of 12V 100 AH SMF battery with 3 years warranty, including wire leads, connections etc complete.Makes: Quanta / Racket / Exide equivalent
Supply and fixing of 12V 150 AH SMF battery with 3 years warranty, including wire leads, connections etc complete.Makes: Quanta / Racket / Exide equivalent
Supplying, Installation, Testing and Commissioning of ISI Marked vertical Multi Stage submersible pump set contain with stainless steel shaft and cast iron/SS body, the pump shall be designed to prevent over loading and having dynamically balanced rotating parts etc. the pump capable of delivering following capacities discharge at suitable head and lowering the pumps in water bodies and suitable for operation on 415V(+-10%), 3- phase AC supply including providing required no's of heavy duty M.S clamps made of flat iron and suitable size top cover made of suitable thick MS sheet as required. suitable for 1200LPM at14 mtr. head etc. complete as required.
Removing, lowering of Submersible water pumps, including required to make the pump Operational Complete as required.
Supply of Diesel, incl. transportation on an emergency basis.
High-Skilled (Fire & safety Officer / Firefighting Sr. Technician) Fire Officer – Duties & Responsibilities The Fire Officer is responsible for ensuring fire safety, prevention, and emergency preparedness across the premises. Core duties include: 1. Monitoring & Inspection o Conduct regular inspections of buildings, fire safety equipment, and escape routes. o Check the pressure in all fire hose cabinets and ensure water availability in fire tanks. o Inspect and maintain all fire extinguishers in operational condition. o Test and verify functionality of fire alarm systems, zone-wise. 2. Training & Awareness o Organize and supervise periodic fire and evacuation mock drills. o Provide guidance on handling fires, earthquakes, and other hazards. 3. Preventive Maintenance & Record Keeping o Oversee maintenance schedules for fire systems and equipment. o Maintain logs, inspection records, and compliance documentation as per statutory requirements. 4. Emergency Response o Take charge during any fire or emergency situation, ensuring immediate and safe evacuation. o Coordinate with local fire services and emergency agencies. 5. Compliance & Reporting o Ensure compliance with fire safety regulations and standards. o Report hazards or deficiencies to management with corrective action recommendations.All works to be carried out as directed by the Engineer-in-Charge. 6 .Eligibilty criteria Qualification & Experience: • Diploma/ITI in relevant trade. • Minimum 5 year of experience in Fire Safety or 10 years in case of an ITI certificate
Highly Skilled (Firefighting technician cum Fire operator /Fireman) (* In accordance with ESIC Hqrs circular dated 26.04.2019) Fireman – Duties and Responsibilities 1. Monitor and conduct daily inspections of buildings to prevent fire and other hazards. 2. Inspect and ensure all fire extinguishers are in proper working condition. 3. Conduct regular fire safety mock drills. 4. Provide training to staff on handling emergencies such as fire, earthquake, and other hazards. 5. Check and maintain pressure levels in all fire hose cabinets. 6. Ensure adequate water availability in the fire tank at all times. 7. Inspect and test the fire alarm system on a zone-wise basis. 8. Inspect, operate, and maintain equipment in the fire pump room. 9. Perform firefighting operations in the event of a fire. 10. Assist in the safe evacuation and rescue of patients and staff during a fire incident. 11. Prepare detailed reports for any fire-related incidents or identified hazards. All works to be carried out as directed by the Engineer-in-Charge. 6 .Eligibilty criteria Qualification & Experience: • Diploma/ITI in relevant trade. • Minimum 3 year of experience in Fire Safety.
High-Skilled Supervisor (Electrical Maintenance) – 01 No. Qualification: Option 1: B.Tech / Diploma in Electrical Engineering with minimum 5 years’ relevant experience. Option 2: ITI with minimum 10 years’ supervisory experience in electrical maintenance. Mandatory: Diploma or ITI Certificate with at least 3 years’ experience in operation of 11KV / 415V substation and equipment and DG Sets, along with valid 11KV / 415V Supervisor Permit / C-Certificate / Grade-C License. Duties & Responsibilities: Monitoring & Maintenance – Oversee day-to-day electrical maintenance works and ensure timely repairs/replacements of damaged fittings/fixtures in the campus, including switches, sockets, switch boards, HT/LT Panels, MCBs, MCB DBs, MCCBs, SFUs, FSUs, fans, light fittings, underground cables, Knowledge on UPS etc., as directed by the Engineer-in-Charge. Logbooks & Records – Maintain and update: Complaint Register Duty Roster Material Consumption Register Log Books / Log Sheets for all preventive maintenance of E&M equipment (lifts, panels, substations, DG sets, fire equipment, RO, STP, ETP, etc.) HT Metering & Calibration – Monitor and maintain all parameter readings of the HT Metering Cubicle; ensure timely calibration of HT VCBs, LT ACBs/MCCBs, Earth Fault Relays, and Over Current Relays.
Skilled – Electrician / Substation attendant cum DG set Operator Responsibilities: Operate and monitor day-to-day functioning of: Substation equipment DG Sets LT Panels, MCBs, MCB DBs, MCCBs, SFUs, FSUs,UPS (Changing of Batteries). All types of fans and light fittings Underground (UG) cables Carry out inspection and daily routine checks of the above-mentioned equipment as per the standard checklist. Maintain logbooks and update shift registers daily as directed by the Engineer-in-Charge. Attend to electrical complaints and carry out necessary repairs/replacements promptly. All works to be carried out as directed by the Engineer-in-Charge. Qualification & Experience: ITI Certificate in Electrical or related trade. Minimum 3 years’ relevant experience. Must be able to maintain logbooks and records at their level.
RO / Water Purifier Operator:- Role Purpose: Responsible for the operation, maintenance, and monitoring of Reverse Osmosis (RO) plants, water purifiers, and associated equipment to ensure a continuous supply of safe, potable water. Duties & Responsibilities Operation & Monitoring Operate RO plant, water softeners, and purification systems as per standard procedures. Monitor inlet/outlet water quality parameters (pH, TDS, hardness, chlorine levels, etc.). Maintain daily logbooks of plant operation, readings, and water test results. Maintenance Perform routine cleaning, flushing, and chemical dosing of membranes and filters. Replace cartridges, filters, and membranes as per schedule or requirement. Troubleshoot and repair minor faults in pumps, pipelines, valves, and controls. Ensure preventive maintenance as per manufacturer’s guidelines. Quality Assurance Conduct regular water testing to ensure compliance with BIS/WHO drinking water standards. Maintain records of water quality and report any deviation immediately.Safety & Compliance Follow all safety protocols while handling chemicals like antiscalants, chlorine, and cleaning agents. Ensure proper chemical storage and usage. Comply with environmental and health regulations. Coordination & Reporting Coordinate with supervisors for procurement of spare parts, chemicals, and consumables. Report breakdowns promptly to the maintenance team/engineer. All works to be carried out as directed by the Engineer-in-Charge. Qualification Requirements Educational: ITI / Diploma in Mechanical, Electrical, or Chemical Engineering OR 10th / 12th pass with relevant RO operation training. Certifications (Preferred):Experience Requirements Freshers may be considered for small-scale units with on-job training. Preferred: 2–3 years experience in operation & maintenance of RO plants, water purifiers, or industrial water treatment systems. Familiarity with different types of RO systems (domestic, commercial, or industrial). Knowledge of preventive maintenance schedules and basic electrical/mechanical repairs. Short-term course in water treatment plant operation from a recognized institute.
AC Technician (Skilled): The AC Technician is responsible for the installation, maintenance, troubleshooting, and repair of air-conditioning systems and related equipment in the premises. The role ensures efficient operation of cooling systems to maintain a safe, comfortable, and energy-efficient environment. Duties and Responsibilities: 1. Installation & Commissioning o Install air-conditioning units (window, split, cassette, and package units) as per manufacturer guidelines. o Commission new systems, ensuring proper functioning and safety compliance. 2. Preventive Maintenance o Conduct routine inspection and servicing of all AC units. o Clean air filters, condensers, and evaporators to maintain optimal performance. o Check refrigerant levels, pressures, and system efficiency. 3. Repairs & Troubleshooting o Diagnose faults in AC systems, control circuits, and related components. o Repair or replace defective parts such as compressors, fans, motors, and thermostats. o Handle gas charging, leak detection, and sealing of leaks. 4. Emergency Response o Attend to breakdown calls promptly to restore cooling in critical areas. o Implement temporary or permanent fixes depending on urgency. 5. Documentation & Reporting o Maintain service logs, maintenance records, and breakdown reports. o Update asset registers and coordinate with the Engineer-in-Charge for major repairs or replacements. 6. Safety & Compliance o Follow all safety protocols, including proper handling of refrigerants. o Ensure compliance with environmental guidelines for gas disposal and energy use. All works to be carried out as directed by the Engineer-in-Charge. Required Skills & Qualifications: • ITI/Diploma in Refrigeration and Air Conditioning or equivalent. • Minimum 2–3 years of experience in AC maintenance and repair. • Knowledge of HVAC systems, refrigerants, and control systems. • Ability to read and interpret technical manuals and wiring diagrams.
Lift Operator – Responsibilities: • Safe Operation: Operate lifts and elevators safely, ensuring smooth movement and passenger comfort. • Loading/Unloading Assistance: Help passengers, including patients and staff, safely enter and exit the lift. • Safety Compliance: Monitor lift operations to ensure adherence to safety standards and operational protocols. • Maintenance Support: Keep lift areas clean, organized, and free from obstructions; assist in routine operational checks. • Emergency Handling: Implement emergency procedures, including safe evacuation of passengers in case of lift malfunction. • Supervision (as applicable): Oversee lift operations and coordinate with maintenance teams when required. Qualification & Experience: • Diploma/ITI in relevant trade. • Minimum 3year of experience in operation and maintenance of lifts.
Pump Operator – Work profile & Responsibilities: 1. Operation & Monitoring Operate and control water pumps, sewage pumps, firefighting pumps, or other assigned pumping systems as per standard procedures. Start, stop, and regulate pumps based on operational requirements and instructions from the Engineer/Officer-in-Charge. Monitor gauges, meters, and control panels to ensure proper pressure, flow rate, and operational parameters. 2. Inspection & Maintenance Conduct routine inspection of pumps, motors, pipelines, valves, and control systems to identify leaks, vibrations, unusual noises, or performance issues. Lubricate and clean pump components as required. Perform minor repairs and adjustments; escalate major faults to maintenance staff. 3. Record Keeping Maintain a daily logbook of pump operation hours, readings, fuel/electricity consumption, and maintenance activities. Report any malfunction or abnormal readings immediately to the supervisor. 4. Safety & Compliance Follow all safety protocols while operating pumps and handling associated equipment. Ensure compliance with operational standards, manufacturer guidelines, and statutory safety norms. Keep the pump house clean, organized, and free from hazards. 5. Emergency Response Respond promptly to emergencies such as pump failure, power outage, or flooding. Operate standby systems like diesel-driven pumps during electrical failures. 6. Coordination Work in coordination with electricians, fitters, and other maintenance staff for smooth operations. Attend scheduled training programs to update operational and safety knowledge. All works to be carried out as directed by the Engineer-in-Charge. Qualification & Experience: • Diploma/ITI in relevant trade. • Minimum 1 year of experience in operation and maintenance.
Unskilled – Helper To assist skilled personnel such as Electricians and AC Technicians in the day-to-day maintenance of electrical works, including: Repairs to internal and external electrical supply systems by replacing worn-out fittings/fixtures. Repairing unserviceable fittings/fixtures such as switches, sockets, switch boards, LT Panels, MCBs, MCB DBs, MCCBs, SFUs, FSUs, etc. Maintenance of all types of fans, light fittings, overhead (OH) lines, underground (UG) cables, etc. All works to be carried out as directed by the Engineer-in-Charge.
stage.html
html • 0.02 MB
tech_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 8.83 MB
FinalNITElectricalARM.pdf
Tender Documents • 8.82 MB
GCC_CON_Misc_30_Construction_Works_2023.pdf
Additional Documents • 23.40 MB
BOQ_944441.xls
BOQ • 0.78 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .