Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Infra Updates
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹15.8 LAccepted-AOC | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹23.7 L+₹7.9 L (50.3%)Rejected-Finance | L2 | Rejected-Finance Other than L1 | |
| 3 | L3₹24.0 L+₹8.3 L (52.4%)Rejected-Finance | L3 | Rejected-Finance Other than L1 |
Tender Value
₹34.2 L
EMD Value
₹68,460
Closing Date
13 Sept 2024, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
CWE, HQ 134 Works Engineers
HQ 134 Works Engineers PIN-914134 C/o 56 APO
REPAIR OR MAINT OF 11 KV AND 33 KV HT ELECT INSTALLATION INCLUDING CONNECTED ITEMS SUCH AS TRANSFORMERS, VCB, CT OR PT, GOD, DO FUSES, AVR CABLES ETC AT JAK LI RC UNDER GE 970 EWS
2024_MES_667586_1
134WE-28(T)/2024-25
Open Tender
Civil Works - Others
Item Rate
180 days
GE 970 EWS
As per tender documents
9 documents required · 9 mandatory
₹500
GE 970 EWS
₹68,460
Yes
19 Oct 2024
24 Jul 2024
16 Sept 2024
24 Jul 2024
13 Sept 2024
7 Aug 2024
25 Jul 2024 - 31 Jul 2024
Amount
Excavation in trenches not exceeding 1.5 meter wide and not exceeding 1.5 meter in depth for foundation for erection of poles, stays, laying cables/pipes, stays etc. and getting out in hard / dense soil, complete all as specified and directed.
Excavation in trenches not exceeding 1.5 mtr wide and exc 1.5 mtr but not not exc 1.5 meter in depth for foundation for erection of poles, stays, laying cables/pipes, stays etc. and getting out in hard / dense soil, complete all as specified and directed.
Returning, filling in including spreading, leveling, watering and well ramming in layers not exc 25cm thick, complete all as specified and directed.
Removing excavated material (soil) to a distance not exc 50 mtr and depositing where directed at a level not exc 1.5 mtr above the starting point, complete all as specified and directed.
M&L for dry river sand, laid in trenches for cable protection, as 15cm thick below the cable and 8cm thick above the cable, complete all as specified and directed. Note :- Punned thickness of sand shall be measured & paid.
Supplying and Laying reinforced precast concrete cable cover, class HV, type-2, flat, of size 450x180x40mm, complete all as specified and directed.
M&L for replacement of 80mm bore GI tubing, light grade, laid in trenches, road crossing, cable protection or fixed to walls with MS clamps, complete all as specified and directed.
All as per Srl item No. 7.00 above, but 100mm bore pipe.
M&L for Plain cement concrete 1:4:8, type D-2 (using 40mm graded crushed stone aggregate) as in foundation, filling in and mass concrete including necessary form work, complete all as specified and directed.
M&L for Plain cement concrete 1:3:6, type C-1 (using 20mm graded crushed stone aggregate) as in foundation filling in and mass concrete including necessary form work, complete all as specified and directed.
M&L for 40mm graded coarse aggregate (broken stone or boulders), laying in sub - station yard, complete all as specified and directed.
M&L for Plain cement concrete 1:2:4, type B-1 (using 20mm graded crushed stone aggregate) as in coping including necessary form work, complete all as specified and directed.
Dismantling old and unserviceable steel poles of any type including breaking cement concrete complete and S&F and erection of steel tubular swaged pole with cast iron base plate finial tapper plug, bolts, nuts and screws and specified type 410-SP-55 (11mtr long) in truly vertical position, 1.5 mtr length of pole above ground level shall be painted with two coats of synthetic enamel paint in strips of 30cm width, black and yellow alternatively and painting with two coats of aluminum paint over a coat of red oxide primer on rest part of pole and its connected parts, complete all as specified and directed. Note :- Earth work and PCC shall be measured and paid seperately under respective items of BOQ.
Dismantling of existing old unserviceable earth wire and cradle guard of any size form any position and S&F new GI wire 4mm dia (8 SWG) on poles to continuous earth wire and cradle guard etc, complete all as specified and directed.
M&L for replacement of stay assembly complete with 20mm dia stay rod with accessories shown in electric plate No 01 of SSR Part-II 2009 including stay clamps, complete all as specified and directed. Note :- Loop insulator, stay wire, excavation and concrete work shall be measured and paid seperately under respective items of BOQ.
S&F in repair galvanised stay wire of size 7/4mm, complete all as specified and directed.
S&F in replacement loop type insulator, vitreous porcelain white or brown of size 90mm x 140mm, clearance hole 25.5mm, complete all as specified and directed.
S&F in replacement disc type insulator, porcelain vitreous, brown or white, suitable for 11 KV HT working pressure of size 145mm height x 255mm dia including one galvanised mild steel spindle, two galvanised iron washer and one GI nut, complete all as specified and directed.
S&F in replacement pin type porcelain vitreous, brown or white insulator, suitable for 11 KV HT of working pressure of size 150mm height, 150mm dia including one galvanised mild steel spindle, two galvanished iron washer and one GI nut, complete all as specified and directed.
S&F in replacement pin type porcelain vitreous, brown of white insulator, suitable for 1100 volt working pressure of size 100mm height x 65mm dia, including one galvanised mild steel spindle, two galvanished iron washer and one GI nut, complete all as specified and directed.
S&F in replacement shackle type porcelain vitreous brown or white insulator, suitable for 1100 volt working pressure, of size 115mm dia x 100mm height including GI strap of size of 31x 5mm insulator bolt of 14mm dia, nuts and washers, complete all as specified and directed.
S&F in replacement including testing of swing out explusion fuse insulator assembly with fuse carrier, outdoor type, 11 KV supply 50 Amps (DO fuse) capacity including mounting bracket and post insulators, complete all as specified and directed.
S&F in replacement transmission class type expulsion fuse, 11000 Volts rating 25-50 Amps, outdoor type, complete all as specified and directed.
Taking down triple pole mechanism complete from site and supply & installation DO fuse unit triple pole, mechanically operated, mounted on insulator and steel frame with opertaing mechanism, worked from ground level with GI pipe medium grade, for current rating upto 200 Amps and Air break (switch) insulator suitable for HT 11 KV outdoor type 50 Amps, complete all as specified and directed.
S&F in replacement lightning arrestor, expulsion type complete with all fittings, transmission class, discharge capacity of 65 Kilo Amps, suitable for 11 KV, complete all as specified and directed.
S&F in repair cable jointing kit for 11KV grade cable for outdoor termination, heat shrink type joint, complete with jointing material and accessories, suitable for size 3 core XLPE armoured aluminium conductor cable of size 50 to 95 sqmm, complete all as specified and directed.
All as per Srl item No. 26.00 above, but cable size 3 core, 120 to 185 Sqmm, complete all as specified and directed.
S&F in repair cable jointing kit for 11 KV grade cable for indoor termination, heat shrink type joint, complete with jointing material and accessories, suitable for size 3 core XLPE armoured aluminium conductor cable of size 50 to 95 sqmm, complete all as specified and directed.
All as per Srl item No. 28.00 above but cable size 3 core 120 to 185 Sqmm, complete all as specified and directed.
S&F in repair cable jointing kit for 11 KV grade cable for straight through joint, heat shrink type joint, complete with jointing material and accessories, suitable for size 3 core XLPE armoured aluminium conductor cable of size 50 to 95 Sqmm, complete all as specified and directed.
All as per Srl item No. 30.00 above but cable size 3 core 120 to 185 Sqmm, complete all as specified and directed.
M&L for painting of HT/LT panel of any description with one coat of synthetic enamel paint of standard colour code by using spray gun over the existing painted surfaces after preparing the old painted surfaces, complete all as specified and directed.
Supply, laying, testing and commissioning XLPE cable, PVC insulated, screened PVC bedded galvanised steel strip or wire armoured electric power cable, heavy duty with aluminium conductor 11000 Volts grade (earthed), of size 3 core, 95 Sqmm, laid in trenches / floor / duct throgh GI pipe, complete all as specified and directed.
All as per Srl item No. 33.00 above, but cable of size 3 core, 120 Sqmm, complete all as specified and directed.
Repairing / Servicing the air break isolating switch of HT 11 KV 200/400 Amps by replacing the defective major spares including provn of minor bolts, nuts etc, complete all as specified and directed. Note :- Major spare parts shall be measured & paid seperately under relevant items of BOQ.
S&F in repair following 11 KV Airbreak switch spares, complete all as specified and directed.
Male contact/ moving contact blade.
Female contact / fix contact jaw.
MS jumper carrier.
Back connector plate.
Petroleum Jelly.
Repairing / Servicing the air break isolating switch of HT 33 KV 200/400 Amps by replacing the defective major spares including provn of minor bolts, nuts etc, complete all as specified and directed. Notes :- Major spare parts shall be measured & paid seperately under relevant items of BOQ.
S&F in repair following 33 KV Airbreak switch spares, complete all as specified and directed.
Male contact/ moving contact blade.
Female contact / fix contact jaw.
Rotating contactor pipe 200/400 Amps.
MS jumper carrier.
Back connector plate.
M&L for PVC insulated armoured heavy duty, single strand, solid copper conductor electric cable, 1100 Volts grade with cross sectional area of size 12 Core, 2.5 Sqmm, complete all as specified and directed.
S&F in replecement drop out (DO) fuse unit, expulsion type, outdoor three pole 200 Amps suitable for HT 33 KV, comprising of 6 Nos post insulators, GI steel base mounting frame, GI nuts, bolts etc. with 30A, HT barrel type fuse, complete all as specified and directed.
S&F in replacement including testing and commissioning of (GOD) gang operated type air break isolating switch horizontal / vertical type mounting complete, double break and operation rod of suitable length 400 Amps with 09 Nos post insulators and suitable for 33 KV HT supply, complete all as specified and directed.
S&F in replacement lighting arrestor, zinc oxide gap less type, station class suitable for 33 KV /10 KA, complete with all fittings, complete all as specified and directed.
S&F in replacement single post insulator, 33 KV with mounting spindle etc, complete all as specified and directed.
S&F in replacement pin insulator, 33 KV with mounting spindle etc, complete all as specified and directed.
S&F in replacement disc insulator, 33 KV with hardware fittings etc, complete all as specified and directed.
M&L for preparation of old painted external surfaces of HT, 2 pole structure consisting of HT 11 mtr steel pole, cross arms, GOD assy with pipe, DO fuse assy, clamps etc, of any description and applying one coat of aluminium paint manually, complete all as specified and directed. Note :- The rates inclusive of painting all minor items such as clamps, brackets, nuts, bolts and washers which is not particularly mentioned in the structures & each job will be measured and paid.
M&L for preparation of old painted external surfaces of HT, 4 pole structure consisting of HT 11 mtr steel pole, cross arms, GOD assy with pipe, DO fuse assy, clamps etc, of any description and applying one coat of aluminium paint manually, complete all as specified and directed. Note :- The rates inclusive of painting all minor items such as clamps, brackets, nuts, bolts and washers which is not particularly mentioned in the structures & each job will be measured and paid.
M&L for preparation of old painted surfaces of HT 33/11 KV MRS (Old System and New MAP system) at Old Air Field, consisting of steel poles / ISMBs, cross arms, GOD pipe, clamps etc. having of any description and applying one coat of aluminium paint manually, complete all as specified and directed. Notes :- (a) The rates inclusive of painting all minor items such as clamps, brackets, nuts, bolts and washers which is not particularly mentioned in this item. (b) The painting work will be carried out during Holidays only to avoid electric shut down.
S&F in replacement including testing of metering & protection current transformer oil filled, outdoor type of 33 KV capacity ratio 100-50/5 or 200-100/5 class=5P, 10/1 15 VA including dismantling old existing CT, complete all as specified and directed. Note :- Calibration and testing record of the same shall be submitted by the contractor to the Engr-in-Charge.
S&F in replacement cable end box heat shrinkable type, outdoor type, suitable for XLPE cable 3 core 120-185 Sqmm, 33 KV HT supply, complete all as specified and directed.
S&F in repair incl testing of material & protection PT unit, 11000/110 volts draw out type, epoxy resin cast type, taking out contact with lead and bushing from the bus bar and PT, replacing by new one of same model suitable for 11 KV VCB including testing on completion, complete all as specified and directed.
M&L for cutting and trimming of tree branches of girth 25mm to 75mm to 3mtr all around of any size, which is obstructing illumination of street light and touching LT/ HT over head line, by using required tools and plants including removing trimmed tree branches, complete all as specified and directed by Engineer-in-Charge. Note :- Each cutting and trimming will be measured and paid separately.
S&F in replacement of synthetic insulating rubber mat, ISI Marked of size 2 mtr x 1 mtr x 19mm, suitable for 11/33 KV as per IS-15652-2006 (Superseeding IS-5424) suitable for electric sock safety at 33 KV MRS at Old Air Field, complete all as specified and directed.
S&F in replacement temperature gauge, suitable size for power transformer / AVR of any capacity, complete all as specified and directed.
S&F PVC sleeves, suitable for LT/HT ACSR conductor/ jumper in any type, in R Y B colours superior quality, inserted over the existing ACSR, complete all as specified and directed.
M&L for preparation of old surface, cleaning the surface of the steel pole (HT) 11 mtr long in pole structures above the ground level including coping area and painting with two coats of aluminum paint on rest part of pole and its connected parts, complete all as specified and directed.
S&F in replacement bolted type LM 6 alloy aluminium rigid stud type terminal connector of type universal connector suitable for 33/11 KV type ACSR conductor / busbar, complete all as specified and directed.
S&F in repacement bolted type LM 6 alloy aluminium rigid pad type terminal connector for pad to conductor suitable for 33/11 KV type ACSR conductor, complete all as specified and directed.
S&F in repairs bolted type LM 6 alloy aluminium rigid parallel connector conductor to conductor suitable for 33/11 KV type ACSR conductor, complete all as specified and directed.
Taking out the existing HT AVR unit 11000 volts grade (Make : Yule brentford) carefully by dismantling all incoming & outgoing elect/ mechanical connections lifting and transport to reputed work shop by means of using suitable tools & plants,opening the body of buckbooster/ AVR units find out the defects and servicing, repair/ removing including replacing the defective spare parts and re-assembling, complete all as specified and directed (De-hydration of oil/ new winding willbe measured and paid under relevant item of this BOQ). The job involves the following :- (a) Dismantling & taking down carefully from plant room by disconnecting all electrical/ mechanical connection from HT and LT side including transporting to work shop. (b) Opening the body of the AVR/ buck booster units complete, drain out the oil, lift the cover and coil assemble, checking the serviceability state of spares such as moving carbon roller, windings, insulating oil, LT/ HT elect connections, HT/ LT bushings, HT/ LT brass terminals, tig & tag connectors, chain rack, limit switch, bearings, couplings, motor, micor porcessor based PCB card, CT/PT assembly, Aux/ reverible contactors, winding/ oil temp/ buchloz relays assembly, earthing connections, copper strip etc. and repair/ replace the same existing model/ make and making fully serviceable state of AVR/ buck booster assembly at site including testing as per OEM specifications, complete all as specified and directed. (c) Cleaning the core laminations assembly by oil complete, removing the carbon sediments. dust in the coil and core gently without making any damage to coil and core. (d) Re-assembling all dismantled parts including provision of new gasket, nut, bolts, refilling with transformer oil and transporting back to original location including electric/ mechanical connection testing and commissioning, complete all as specified and directed.
S&F in replacement moving carbon rollers of existing size and make, suitable for 1500 KVA AVR unit, complete all as specified and directed.
S&F in replacement tie & tac brass connectors, suitable for 1500 KVA AVR unit, complete all as specified and directed.
S&F in replacement chain rack (double) including bearing, suitable for 1500 KVA AVR unit, complete all as specified and directed.
S&F in replacement limit switch, suitable for 1500 KVA AVR unit, complete all as specified and directed.
S&F in replacement SS coupling, suitable for 1500 KVA AVR unit, complete all as specified and directed, complete all as specified and directed.
S&F in replacement chain assy, suitable for 1500 KVA AVR unit, complete all as specified and directed.
S&F in replacement synchronous motor, suitable for 1500 KVA AVR unit, complete all as specified and directed.
S&F in replacement PCB card, suitable for 1500 KVA AVR unit, complete all as specified and directed.
S&F in replacement PT unit 11000/ 110 Volts, suitable for 1500 KVA AVR buck booster unit, complete all as specified and directed.
S&F in replacement reversible contactor 3 pole 800 Amps, suitable for 1500 KVA AVR unit, complete all as specified and directed. Make :- Yule Cat part No. PAK 600U (SPL) or equivalent.
S&F in replacement winding temperature relay complete, suitable for 1500 KVA AVR unit, complete all as specified and directed.
S&F in replacement oil temperature relay complete, suitable for 1500 KVA AVR unit, complete all as specified and directed.
S&F in replacement buchloz relay assy complete, suitable for 1500 KVA AVR unit, complete all as specified and directed.
S&F in replacement copper strip of any size, suitable for 1500 KVA AVR unit, complete all as specified and directed.
S&F in replacement connector strip 16/ 24 way, suitable for 1500 KVA AVR unit, complete all as specified and directed.
S&F in replacement aux contactor, suitable for 1500 KVA AVR unit, complete all as specified and directed.
Taking down carefully the existing 11KV/433 V distribution transformer of capacity 300 KVA to 600 KVA by disconnecting HT overhead connection / underground cables and earth strips etc, from any substation / locations using suitable capacity of crane or by any other mechanical method irrespective of type of approach available, loading in vehicle, transportation to workshop for repairs and unloading carefully. Reloading the tranformer after repairs and testing of transformer, transportation to site and unloading including placing at given/ existing position and re-commissioning complete all as specified and directed. Note :- All required T&P for disonnection, connection, loading and loading including necessary petty items such as bolts, nuts etc will be arranged by the contractor and rates for the same deemed to be included in the quoted rates.
M&L for repairs toTransformer step down 11KV/0.433 KV of any type of capacity 63 KVA to 300 KVA, after dismantling the transformer body carefully, opening the top cover of transformer for inspection / repair, drain out the transformer oil from the tank complete, taking out the core and winding assy by disconnecting the internal connections, removing the carbon/ sludge deposit in transformer housing core, renewal/ replacement of u/s rubber bushes and washers, replacement of tap changer winding and thimbles, replacement of silica gel, replacement of top cover gasket set including pasting with pasting material, replacement of worn out nut and bolts, replacement of unserviceable LT & HT bushes, cutting the burnt out winding and re-winding the same with suitable size of super enamelled copper wire as per existing guage, insulating the winding connection by using fire proof sleeve and fire proof tape, warnishing the coil, keeping the coils in electric oven chamber for 24 hrs to remove the moisture, Painting of complete transformer body from outside and inside by weather proof type using spray gun, Marking of MES/SM Number etc, replacement of conservator tank glass, re-intalling the core and winding inside properly, making the all connection with suitable copper lugs, refilling of dehydrated transformer oil including dehydration, reinstalling the top cover after cleaning and painting of housing, conservator tank, expulsion vent etc, Meggering the LT and HT side of the Transformer and testing complete all as specified and directed. Note :- Winding wire including labour for making of coils and LT/HT bushes will be measured & paid seperately.
All as per Srl item No 78.00 above, but of capacity 11 KV/0.433 KV, 300 KVA to 600 KVA, complete all as specified and directed.
Supply and filling of fresh transformer power oil of BDV not less than 50 KV for topping up of reduced level of transformer due to evaporation / leakage / losses due to dehydration in HT 33 KV transformerv / HT 11 KV AVTR / Distribution transformer 100 to 600 KVA or for replacement complete including removing of old unservicable transformer oil, complete all as specified and directed. Note :- Proper document should be maintained by the contractor and submit to Engr-in-Charge.
M&L for conducting oil filtration by stream line / vacuum type filter machine to remove the moisture / carbon particles to improve required BDV of oil 50 to 60 KV for 1 min for power transformer & as BDV of oil 40 to 50 KV for 1 min for distribution transformer incl routine testing after filtration for any capacity of transformers/ AVR/CT/ PT units, complete all as directed. Notes :- (a) The contractor shall be change the filter assy before starting the filtration of power / distribution transformer of capacity 600 KVA and more in presence of Engr-in-Charge. (b) Proper document should be maintained by the contractor and submit to Engr-in-Charge.
S&F in replacement brass terminal rod with nuts, bolts washers & bushings, suitable for HT side of the transformer of any make and capacity from 100 KVA to 300 KVA, complete all as specified and directed.
All as per Srl item No. 82.00 above but LT side, complete all as specified and directed.
S&F in replacement of brass terminal rod with nuts, bolts washers & bushings suitable for HT side of the transformer of any make and capacity from 315 KVA to 600 KVA, complete all as specified and directed.
All as per Srl item 84.00 above but LT side, complete all as specified and directed.
Supply and replacing silica gel breather clear view type including first fill of good quality silica gel of capacity suitable for 100 KVA to 300 KVA transformer, complete all as specified and directed.
Supply and replacing silica gel breather clear view type including first fill of good quality silica gel of capacity suitable for 315 KVA to 600 KVA transformer, complete all as specified and directed.
M&L for painting the outer surface of the transformer with one coat of weather proof paint after preparing the surface dust and oil free and cleaning the bushes, name plate etc, paint free after painting including writing the MES/SM Number with white enamelled paint, complete all as directed for capacity of transformer 100 KVA to 600 KVA (Indoor/outdoor type), complete all as specified and directed.
All as per Srl item No 88.00 above, but for capacity of transformer 1000 KVA to 2000 KVA (Indoor/outdoor type), complete all as specified and directed.
Supply and replacing silica gel breather clear view type including first fill of good quality silica gel of capacity suitable for 1000 KVA to 2000 KVA transformer/ AVR units, complete all as specified and directed.
M&L for earthing complete with galvanised steel earth plate electrode of size 600x600x6mm thick, burried directly in ground, earth pit not less than 2.25 mtr deep below normal ground level with top edge of earth plate not less than 1.5 mtr below normal ground level, connected to the galvanised iron strip of size 32x6mm by means of bolts, nuts, check nuts and washers of galvanised iron, protected by GI tube light grade 40mm bore including provision of concrete pit in PCC 1:2:4 type B-1 (using 20mm graded stone aggregates) with 40mm thick RCC 1:2:4 cover, reinforced with XPM weight not less than 4 Kg /Sqm and 6mm dia round bar handle, excavation and earth work in any type of soil, charcoal dust and salt and 20mm bore GI watering pipe light grade with funnel and wire mesh including dismantling old UNSV earthing and removal thereof, complete all as specified and directed. Notes :- (i) Main earthing strip from earth plate electrode to test point up to length of 7.5 meters length shall deemed to be include in quoted rates. (ii) On testing after completion if the desired resistenance is not obtained the contractor shall redo the earthing without any extra cost to the department .
S&F in replacement off load tap changer for distribution transformer of any make and capacity from 200-600 KVA, complete all as specified and directed.
M&L for super enamelled copper conductor wire of 9/13/14/18/24 gauge of copper content and size as per requirement for rewinding the HT/LT transformer / HT AVR of any capacity and any make, complete all as specified and directed.
M&L for super enamelled aluminium conductor wire of suitable gauge and size as per requirement for rewinding the LT transformer / AVR of any capacity and any make, complete all as specified and directed.
S&F in replacement bush type insulator white / brown / green, working pressure 433 Volts LT side, complete all as specified and directed.
M&L for servicing and repairing of OLTC (ON load Tap changer) for 33 KV Transformer by disconnecting and dismantling all burnt out cables / fuses/ relays / contactors, toggle switch/knobs / indicators / reading units and other accessories repairs / replace the unserviceable items and making the OLTC serviceable condition and connecting back to its original position, complete all as specified and directed.
M&L for servicing of 33 KV VCB / 11 KV VCB / bus coupler by dismantling, cleaning, greasing the complete VCB with attached relays bus bar etc. insulation testing, setting the contact gap by measuring as required re-assembling the VCB and reinstalling back to its original position checking and repairing the current circuit panel wiring, replacement of new spares as required complete including operational testing and commissioning, complete all as specified and directed. Note :- New spare parts shall be measured and paid separately under respective items of this BOQ.
M&L for carrying out primary & secondary injection test of 33 KV or 11 KV indoor / outdoor type current transformer (Set of three) of VCB's by using standard injection test method and checking the electrical circuits for fault condition, all relay testing and proper functioning including submitting the test report, complete all as specified and directed. Note :- PIT / SIT for VCB will be carried out in 6 months intervals and each primary & secondary injection test will be measured and paid and considered as one unit.
Supply and fixing in replacement of the following spares for outdoor VCB 33 KV, 800 A, 750 MVA fault level 36 V-26/2000 & VCB 11 KV 400 Amps 25 KA 250 MVA as approved by GE, complete all as specified and directed.
Closing coil 24/30V DC .
Tripping coil 24/30V DC.
Antipumping device 24/30V DC.
33 KV porcelain bushing for VCB Top.
33 KV porcelain bushing for VCB bottom.
Connector strip 16 Way.
Earth Fault and over current relay of L & T Model No MC61A 24-110V.
Digital type power factor indicator meter.
Digital type Voltmeter / Ammeter 96mm x 96mm size.
LED type indicator lamp assembly.
Vaccum interrupter for indoor VCB.
Spout incoming side.
Spout outgoing side.
Epoxy insulators bushings for incoming / outgoing cables / bus bar suppors as per existng size of VCBs.
Insulated copper bush bar of existing size and thickness for VCBs.
Gear system assy complete with handle for charging / discharging of VCBs.
Spring charging motor for VCBs.
Supply only DO fuse elements 11 KV grade having fire resistant tube and soldred joint with ferrule, 24.5" long crimped joint, stranded silver/tin coated wire of 2.5 to 25 Amp capacity, complete all as specified and directed.
All as per Srl item No. 100.00 here-in-before but 30 Amp to 40 Amp capacity, complete all as specified and directed.
All as per Srl item No. 100.00 here-in-before, but 50 Amp capacity, complete all as specified and directed.
Supply only DO fuse elements 33 KV grade having fire resistant tube and soldred joint with ferrule, 33" long crimped joint, stranded silver/tin coated wire of 2.5 to 25 Amp capacity, complete all as specified and directed.
All as per Srl item No. 103.00 here-in-before but 30 Amp to 50 Amp capacity, complete all as specified and directed.
Restringing only existing HT 11/33 KV/ LT OH line/ Jumpers including dismantling of existing old binding wire for tightening, complete all as specified and directed. Notes :- (a) Restringing of each wire/ span shall be measured as one unit. (b) Binding wire shall be measured and paid separately under relevant item of this BOQ.
Removing of vegitation, grass, scrubs and bushes growing in sub station yard alongwith fencing by manually/ mechanically and keep the sub station yard neat and clean, complete all as specified and directed. Notes :- (a) Unit rates quoted deemed to be include to keep the installation neat and clean through out the period of contract and each cleaning will be measured and paid separately. (b) Neccesary tools shall be arrange by the contractor without any extra cost to Govt.
Dismantling existing old unserviceable ACSR conductor of any size and any description and S&F new ACSR conductor including stringing through existing RCC/ steel poles, fixing in insulators, jumpers with polythene pipe, aluminium binding wire etc. complete of different sizes, complete all as specified and directed. Note :- Rates for new aluminium tape / copper binding wire shall be deemed include in quoted rates.
S&F mild steel cross arms channel, bracing, support, clamps etc, fabricated from structured steel, sections including nuts, bolts, washers etc and cutting to required length beat to any shape, drilling holes, fixed on poles or jointed by means of elect welding complete including painting with two coats of aluminium paint over a coat of red oxide zinc chrome primer after preparation of surfaces including taking down / dismantling the old one/ items, complete all as specified and directed.
S&F in repair/ replacement AAC for binding purpose of not less than 0.9mm dia for tightening the conductors on poles, complete all as specified and directed.
Taking down carefully the existing 33/11 KV distribution transformer of capacity 1000 KVA to 2000 KVA by disconnecting HT overhead connection / underground cables and earth strips etc, from any substation / locations using suitable capacity of crane or by any other mechanical method irrespective of type of approach available, loading in vehicle, transportation to workshop for repairs and unloading carefully. Reloading the tranformer after repairs and testing of transformer, transportation to site and unloading including placing at given/ existing position and re-commissioning complete all as specified and directed by Engr-in-Charge. Note :- All required T&P for disonnection, connection, loading and loading including necessary petty items such as bolts, nuts etc will be arranged by the contractor and rates for the same deemed to be included in the quoted rates.
M&L for repairs to power Transformer step down 33KV/11 KV of any type of capacity 1000 KVA to 2000 KVA, after dismantling the transformer body carefully, opening the top cover of transformer for inspection / repair, drain out the transformer oil from the tank complete, taking out the core and winding assy by disconnecting the internal connections, removing the carbon/ sludge deposit in transformer housing core, renewal/ replacement of u/s rubber bushes and washers, replacement of tap changer winding and thimbles, replacement of silica gel, replacement of top cover gasket set including pasting with pasting material, replacement of worn out nut and bolts, replacement of unserviceable LT & HT bushes, cutting the burnt out winding and re-winding the same with suitable size of super enamelled copper wire as per existing guage, insulating the winding connection by using fire proof sleeve and fire proof tape, warnishing the coil, keeping the coils in electric oven chamber for 24 hrs to remove the moisture, Painting of complete transformer body from outside and inside by weather proof type using spray gun, Marking of MES/SM Number etc, replacement of conservator tank glass, re-intalling the core and winding inside properly, making the all connection with suitable copper lugs, refilling of dehydrated transformer oil including dehydration, reinstalling the top cover after cleaning and painting of housing, conservator tank, expulsion vent etc, Meggering the LT and HT side of the Transformer and testing complete all as specified and directed by Engr-in-Charge. Note :- Winding wire including labour for making of coils and LT/HT bushes will be measured & paid seperately.
M&L for earthing complete with copper earth plate electrode of size 600x600x3.15mm thick, buried directly in ground (earth pit not less than 2.25 mtr deep below from normal ground level), connecting to the copper earth strip of size 20x3mm by means of bolts, nuts, check nuts and washers of galvanised iron and earth lead protected by 40mm bore GI pipe, light grade including provision of conrete pit PCC 1:2:4 type B-1 (using 20mm graded crushed stone aggregates) with 40mm thick cover of RCC (1:2:4) type B-1, reinforced with XPM (weight not less than 4 Kg/Sqm) and frame of angle iron 25x25x3mm and with 6mm dia MS bar handle, made to shape, 20mm bore GI light grade pipe for watering pipe, placed on top edge of earth plate and including common salt and charcoal filling, test point with fixing arrangements, funnel, wire mesh and earth work in any type of soil, returning, filling in and removal of surplus soil to a distance not exceeding 50 mtr, complete as per electrical plate No. 3 of MES SSR Part-I (2009), complete all as specified and directed. Note :- The earthing will be tested after completion, if desire results not achieved, the contractor redo the earthing and rates for the same shall be deemed to include in the quoted rates.
Notes :- An amount of Rs. 3,87,380.00 on account of Credit Schedule for Schedule 'A' Part-II shall be deducted from total quoted amount of BOQ to arrive at the contract sum.
M/S Noor Mohammad Shalla (BID ID -3089932)
M/s Nasir Rasool Dar (BID ID -3085561)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .