| Sl No | Description | Qty | Unit | R D Bansal L1 | Jawandha Enterprises L2 |
|---|---|---|---|---|---|
| 1.00 | Providing labour for deployment of team consistiing of one electrion(ITI qualified) and two helper and providing transport and T&P for locating the fault in HT/LT line in OH/UG Line/cable by visual inspection recce of faulty area and repairs to the fault by means of replacement of Unservicable Jumpers /Fuse wires / Burnt lugs/all type of insulator/ MCCB etc. inclusive restraining of broken/loose ACSR conductorss/Earth wire etc Making tamporary connection if required to make the countinity of supply , The Cable required shall be given by department from AGE E/M store for temporary resume the power supply.The area coming under Sub Station No. 01, 2,05 & 5 ( Map pocket) shall be covered under the subject work complete all as directed by Engineer-in-charge
Note:
(i) Materials requried for fault repairs will be measured under relevant items of this BOQ.
(ii) Contractor will depute the dedicated team (one electician (ITI holder) and two helper)., Contractor will be responsible for the safety of his team deployed. No dispute regarding safety of person would be entertain later on. If any mishappening occures during rectifaction of fault in HT/LT lines contractor will be fully liable to bear all the expenses of staff deployed.
(iii) Contractor will provide all set of T & P such as (a) HV (11000Volts) digital insulation tester (b) LV (1100V) digital insulation tester (c) Digital clamp meter up tp 1100 V and 1000Amps (d) Search light, rain coat (e) Cutting pliers (f) Screw Driver set, box spanner/wretched spanner (g) Allen key set (h) 11000V grade safety gloves, rubber boots, Safety belt and helmets, torch lights etc (i) Earthing rod (j) Bamboo ladder for desired height. (k) PVC tape roll (HV/LV) for routine maintenance and protection of the trademan incl safety equipment such as Hand gloves, Rubber boots, safety belt and helmets etc communication device (Mobile Phone) to deployed persons, Electrcian team (One Electrician (ITI Holder and Two Helper) as per site requirement.
(iv) On intimation of any type of repair/maintenance work of HT/LT switch gear incomer as well as out going feeder the contractor is responsible to locate the fault by the dedicated team comprising tradesman helpers required numbers as per the gravity /nature of the work involved to restore the power supply and communicate with SBA on duty and getting permit card for working on HT lines and deposit the permit card after rectification of fault, all the activities shall be carried out within reasonable time as given by the Engineer-in-Charge.
(v) Contractor will provide necessary complaint slip, complaint boook & permit book, contractor will direct the instructions to indis for lodgging the complaints duly marked the location, time and date for earlier rectifications.
(vi) After getting the complaints, team deployed by the contractor will rectify the complaints within stipulated time i.e within 2 hours from the time of receiving of complaints.
(vii) Contractor should also provide a dedicated supervisor for collection of complaints from SBA, JE, USER etc. He would be held responsible, in case complaints are not collected | 3,500 | Each Job | 130 ₹4,55,000 Lowest | 145 ₹5,07,500 |
| 2.00 | Supply only pin type porcelain, vitreous, white, brown or green insulator incl one galvanised mild steel spindle, two galvanised iron washers and one galvansied iron nut, 150mm height, 150mm dia for 11000 volts grade complete all as specified and directed by Engineer-in-charge. | 65 | Each | 220 ₹14,300 | 200 ₹13,000 Lowest |
| 3.00 | Supply only Disc type porcelain insulator, vitreous 145mm height and 255 dia ball and socket type, white, brown and green " Two in series" assembly for tension with tension clamps for conductor, working pressure 11000 volts grade complete all as specified and directed by Engineer-in-charge. | 30 | Each | 380 ₹11,400 Lowest | 500 ₹15,000 |
| 4.00 | Supply only post insulator, porcelain, vitreous 150 mm high and 255 mm dia ball and socket type, white, brown or green, working pressure 11000 volts complete all as specified and directed by Engineer-in-charge. . | 50 | Each | 240 ₹12,000 | 150 ₹7,500 Lowest |
| 5.00 | Supply only HT Jumper complete all as specified and directed by Engineer-in-charge. Note : Materials requried for fault repairs will be measured under relevant items included in BOQ. | 100 | Each Job | 150 ₹15,000 Lowest | 150 ₹15,000 Lowest |
| 6.00 | Supply and fixing multi-jointed ACSR jumpers.(Length of one jumper not exceeding more than 3.0 mtrs) of HT over head lines with and incudingl XLPE/PVC insulated 11000 volts multi stranded aluminium conductor single core cable of size 120 sqmm as per colour code in sequence Red ,yellow ,blue and black for neutral fixing with ACSR conductors with suitable size PG (Parellel Groove) clamp complete all as specified and directed by Engineer-in-charge. | 150 | Each | 150 ₹22,500 Lowest | 250 ₹37,500 |
| 7.00 | All as per item No. 6 here-in-before but with aluminium conductor single core cable of size 185 sqmm of size 185 Sqmm. | 30 | Each | 300 ₹9,000 Lowest | 350 ₹10,500 |
| 8.00 | Supply and fixing in repalcement aluminium conductor steel reinforced any type conductor as per the site requirement including binding wire and jumper connect with PG clamp made out of aluminium alloy accodring to IS-617 complete all as specified and directed by Engineer-in-charge. | 7 | Qtl | 23,000 ₹1,61,000 | 15,000 ₹1,05,000 Lowest |
| 9.00 | Material and labour for cutting through existing bituminous road /PCC/floor/approx size widthxdepth 50cm X 90cm along cross section of the road for laying of GI tubing/RCC pipe for encasing of cable and repairing the road to match with the original finish complete all as specified and as directed by Engineer-in-charge. | 45 | RM | 200 ₹9,000 Lowest | 250 ₹11,250 |
| 10.00 | Supply and fixing aluminium cable lugs any type suitable for cable of size 10 sqmm including necessary crimping with crimping tool complete all as specified and directed by Engineer-in-charge. | 60 | Each | 10 ₹600 Lowest | 10 ₹600 Lowest |
Tender Value
₹67 L
EMD Value
₹1.3 L
Closing Date
1 Jul 2026, 6:00 pmClosed
CWE Patiala
HQ COMMANDER WORKS ENGINEER BLDG No 26 NEW LALBAGH PATIALA 147001 Contact - 01712200082
REPAIR / MAINT OF HV / LV ELECTRCAL LINE OVERHEAD/UNDER GROUND CABLE, LT PANEL/FEEDER PILLAR, SECURITY LIGHT PANELS, TIMER BOX AT SEC B UNDER GE (SOUTH) PATIALA
2026_MES_769389_1
CWE/PAT/T-04/2026-27
Open Tender
Civil Works
Item Rate
180 days
GE (South) Patiala
Please refer Tender documents.
7 documents required · 7 mandatory
₹1,000
₹1.3 L
8 Aug 2026
3 Jun 2026
3 Jul 2026
3 Jun 2026
1 Jul 2026
24 Jun 2026
3 Jun 2026 - 20 Jun 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Providing labour for deployment of team consistiing of one electrion(ITI qualified) and two helper and providing transport and T&P for locating the fault in HT/LT line in OH/UG Line/cable by visual inspection recce of faulty area and repairs to the fault by means of replacement of Unservicable Jumpers /Fuse wires / Burnt lugs/all type of insulator/ MCCB etc. inclusive restraining of broken/loose ACSR conductorss/Earth wire etc Making tamporary connection if required to make the countinity of supply , The Cable required shall be given by department from AGE E/M store for temporary resume the power supply.The area coming under Sub Station No. 01, 2,05 & 5 ( Map pocket) shall be covered under the subject work complete all as directed by Engineer-in-charge
Note:
(i) Materials requried for fault repairs will be measured under relevant items of this BOQ.
(ii) Contractor will depute the dedicated team (one electician (ITI holder) and two helper)., Contractor will be responsible for the safety of his team deployed. No dispute regarding safety of person would be entertain later on. If any mishappening occures during rectifaction of fault in HT/LT lines contractor will be fully liable to bear all the expenses of staff deployed.
(iii) Contractor will provide all set of T & P such as (a) HV (11000Volts) digital insulation tester (b) LV (1100V) digital insulation tester (c) Digital clamp meter up tp 1100 V and 1000Amps (d) Search light, rain coat (e) Cutting pliers (f) Screw Driver set, box spanner/wretched spanner (g) Allen key set (h) 11000V grade safety gloves, rubber boots, Safety belt and helmets, torch lights etc (i) Earthing rod (j) Bamboo ladder for desired height. (k) PVC tape roll (HV/LV) for routine maintenance and protection of the trademan incl safety equipment such as Hand gloves, Rubber boots, safety belt and helmets etc communication device (Mobile Phone) to deployed persons, Electrcian team (One Electrician (ITI Holder and Two Helper) as per site requirement.
(iv) On intimation of any type of repair/maintenance work of HT/LT switch gear incomer as well as out going feeder the contractor is responsible to locate the fault by the dedicated team comprising tradesman helpers required numbers as per the gravity /nature of the work involved to restore the power supply and communicate with SBA on duty and getting permit card for working on HT lines and deposit the permit card after rectification of fault, all the activities shall be carried out within reasonable time as given by the Engineer-in-Charge.
(v) Contractor will provide necessary complaint slip, complaint boook & permit book, contractor will direct the instructions to indis for lodgging the complaints duly marked the location, time and date for earlier rectifications.
(vi) After getting the complaints, team deployed by the contractor will rectify the complaints within stipulated time i.e within 2 hours from the time of receiving of complaints.
(vii) Contractor should also provide a dedicated supervisor for collection of complaints from SBA, JE, USER etc. He would be held responsible, in case complaints are not collected | 3,500 | Each Job | 1.25 | ₹4,375 |
| 2 | Supply only pin type porcelain, vitreous, white, brown or green insulator incl one galvanised mild steel spindle, two galvanised iron washers and one galvansied iron nut, 150mm height, 150mm dia for 11000 volts grade complete all as specified and directed by Engineer-in-charge. | 65 | Each | 100 | ₹6,500 |
| 3 | Supply only Disc type porcelain insulator, vitreous 145mm height and 255 dia ball and socket type, white, brown and green " Two in series" assembly for tension with tension clamps for conductor, working pressure 11000 volts grade complete all as specified and directed by Engineer-in-charge. | 30 | Each | 100 | ₹3,000 |
| 4 | Supply only post insulator, porcelain, vitreous 150 mm high and 255 mm dia ball and socket type, white, brown or green, working pressure 11000 volts complete all as specified and directed by Engineer-in-charge. . | 50 | Each | 53 | ₹2,650 |
| 5 | Supply only HT Jumper complete all as specified and directed by Engineer-in-charge. Note : Materials requried for fault repairs will be measured under relevant items included in BOQ. | 100 | Each Job | 10 | ₹1,000 |
| 6 | Supply and fixing multi-jointed ACSR jumpers.(Length of one jumper not exceeding more than 3.0 mtrs) of HT over head lines with and incudingl XLPE/PVC insulated 11000 volts multi stranded aluminium conductor single core cable of size 120 sqmm as per colour code in sequence Red ,yellow ,blue and black for neutral fixing with ACSR conductors with suitable size PG (Parellel Groove) clamp complete all as specified and directed by Engineer-in-charge. | 150 | Each | 10 | ₹1,500 |
| 7 | All as per item No. 6 here-in-before but with aluminium conductor single core cable of size 185 sqmm of size 185 Sqmm. | 30 | Each | 22 | ₹660 |
| 8 | Supply and fixing in repalcement aluminium conductor steel reinforced any type conductor as per the site requirement including binding wire and jumper connect with PG clamp made out of aluminium alloy accodring to IS-617 complete all as specified and directed by Engineer-in-charge. | 7 | Qtl | - | - |
| 9 | Material and labour for cutting through existing bituminous road /PCC/floor/approx size widthxdepth 50cm X 90cm along cross section of the road for laying of GI tubing/RCC pipe for encasing of cable and repairing the road to match with the original finish complete all as specified and as directed by Engineer-in-charge. | 45 | RM | 10 | ₹450 |
| 10 | Supply and fixing aluminium cable lugs any type suitable for cable of size 10 sqmm including necessary crimping with crimping tool complete all as specified and directed by Engineer-in-charge. | 60 | Each | - | - |
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.18 MB
Tender042627.pdf
Tender Documents • 0.71 MB
BOQ_861620.xls
BOQ • 0.45 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .