| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹3.9 LAccepted-AOC | ₹3.9 L Quoted ₹4.4 L | L1 | Accepted-AOC low |
| 2 | L2₹4.5 L+₹8,228.80 (1.87%)Rejected-AOC | ₹4.5 L+₹8,228.80 (1.87%) | L2 | Rejected-AOC high |
Tender Value
₹3.8 L
EMD Value
₹8,000
Closing Date
18 Sept 2023, 3:00 pmClosed
EXECUTIVE ENGINEER,ROPAR CANAL AND GW,DIVISION WRD
EXECUTIVE ENGINEER,ROPAR CANAL AND GW,DIVISION WRD
CONSTRUCTION OF CONTROL ROOM OF SCADA AT ROPAR BARRAGE
2023_WR_108342_1
20/22A/2023-24
Open Tender
Civil Works - Buildings
Item Rate
45 days
RUPNAGAR
Please refer Tender documents.
2 documents required · 2 mandatory
₹1,000
Yes
₹8,000
Yes
13 Feb 2024
1 Sept 2023
18 Sept 2023
1 Sept 2023
18 Sept 2023
1 Sept 2023
Amount
Earth work in excavation in foundations trenches etc. in all kinds of soil where Pick-Jumper work is not involved and not exceeding 2.0 metres depth including dressing of bottom and sides of trenches, stacking the excavated soil clear from the edge of excavation and subsequent filling around masonry in 15 cm, layers with compaction including disposal of all surplus soil as directed within lead of 30 metres.
Earth filling under floors with surplus ordinary soil or soil containing gravel or kankar upto 40% excavated from outside the building plinth in 15 cm layers including ramming, watering and consolidating lead upto 30 metres
Shuttering for faces of concrete foundations and foundation beam & plinth beam (vertical or battering).
Centering and shuttering for sides and soffits of beams, launching girders,bressumers,lintels.
Centering and shuttering for flat surfaces such as suspended floors, roofs, landings, chajjas, shelves etc.
Providing and laying Cement concrete GRADE M-15(1:2:4 ) with stone ballast or shingle mixing by mechanical means using concrete mixer volumetric type.
Reinforced cement concrete M-20 mechanically batch mixed using batch type concrete mixer as per IS:1791 and vibrated by needle vibrator but excluding steel reinforcement centring and shuttering foundation and plinth
Reinforced cement concrete M-20 mechanically batch mixed using batch type concrete mixer as per IS:1791 and vibrated by needle vibrator but excluding steel reinforcement centring and shuttering in superstructure
Laying First class burnt brick work laid in cement sand mortar 1:3 in foundation and plinth
First class burnt brick work laid in cement sand mortar 1:3 in first storey upto 4 metres above plinth level.
Laying of Dry Brick Ballast 40 mm gauge for flooring
Providing and laying Anti skid Ceramic floor tiles of size 300x300 mm x 10 mm thick of 1st quality conforming to IS : 15622 of approved make in colours such as White, Ivory, Grey, Fume Red Brown, laid on flooring skirting and dado in 12.5mm thick cement plaster 1:3 in base and jointed with @ 3.3 kg/sqm including pointing the joints with white cement and matching pigment etc., completewhite cement slurry in joints including corners angles and beading.
Cold twisted detormed (Ribbed/ Tor steel) Bars(Fe 500 grade as per IS 1786-2008) , for R.C.C works, where not including in the complete rate of RCC including bending and binding placing in position complete.
Supplying Pressed steel sheet frames (chowkhat) consisting of 18gauge (1.25 mm thick steel sheet of the specified section, including iron lugs (hold fast) iron hinges conforming to PWD specification including bolts for fixing stops lock notch provision for receiving tower bolts and finished with 1 primer coat approved quality, fixed in position excluding the cost of cement concrete 1:3:6 for fillings in the frame and cement concrete 1:2:4 for lugs complete
Doors and windows frame of size 151mm x 60mm with 35 mm wide double rebate weighing 3.95 kg per meter.
12.5 mm thick cement plaster 1:3
Preparation of plastered or concrete surface for painting (including sand papering the surface) using Acyrcllic wall putty by applying two or more coats to get required finish including priming coat before applying acyrclic wall putty
Wall painting with plastic emulsion paint of approved brand and manufacturer to give aneven shade (two or more coats).
Providing and fixing mineral fibre false ceiling tiles ( NRC 0.55 to 0.6) at all heights of size 595X595x16 mm of approved texture, design and pattern. The tiles should have Humidity Resistance (RH) of 99%, Light Reflection > 85%, Thermal Conductivity k = 0.052 - 0.057 w/m K, Fire Performance as per (BS 476 pt - 6 &7)in true horizontal level suspended on interlocking T-Grid of hot dipped all round galvanized iron section of 0.33 mm thick (galvanized @120 gsm) comprising of main T runners of 15x32 mm of length 3000 mm, cross T of size 15x32mm of length 1200 mm and secondary intermediate cross T of size 15x32 mm of length 600 mm to form grid module of size 600x600 mm suspended from ceiling using galvanized mild steel item (galvanised@80gsm) 50 mm long 8mm outer diameter M-6 dash fasteners, 6 mm diameter fully threaded hanger rod up to 1000 mm length and L-shape level adjuster of size 85x25x2 mm, spaced at 1200 mm centre to centre along main ‘T’. The system should rest on periphery walls /partitions with the help of GI perimeter wall angle of size24x24X3000 mm made of 0.40 mm thick sheet, to be fixed to the wall with help of plastic rawl plug at 450 mm centre to centre & 40 mm long dry wall S.S. screws. The exposed bottom portion of all T-sections used in false ceiling support system shall be pre-painted with polyester baked paint, for all heights. The work shall be carried out as per specifications, drawings and as per directions of the engineer-in-charge.
Providing and fixing 110 mm dia . U.P.V.C Rain water pipe of 4 kgf./sqm
Providing and fixing 110 mm dia . U.P.V.C bend for Rain water pipe as per IS:14735 including joint a) UPVC 110MM bend
Deodar wood doors shutter with 12mm thick phenol Bonded BWP ply (Anchor Kit ply, Nova teak , or National or any other ISI approved quality) I/C hinges, screws, chocks & cords etc. Complete fixed in position (Single leaf) phenol bonded ply panel 35 mm thick
Deodar wood doors shutter windows shutter including hinges, screw and cords etc. Complete fixed in position panelled ,glazed or glazed and panelled 35 mm thick
Providing and fixing glass panes with nails and putty or wooden strip complete in all respect 5mm thick plate glass (INDIAN)
Providing and fixing hydraulic door closer ISI mark with necessary screw etc. complete I.S.I Designation No. III (size of door 851mm to 1000mm)
Providing & fixing 6" stainless steel handles ISI marked on door & window frames complete in all respect as per the directions of Engineer-in-charge.
Providing & fixing 8" stainless steel tower bolts ISI marked on door & window frames complete in all respect as per the directions of Engineer-in-charge
Providing & fixing 9" stainless steel handles ISI marked on door & window frames complete in all respect as per the directions of Engineer-in-charge.
Iron Fitting ISI Marked Sliding Bolt 250mm
Wiring in PVC insulated copper conductor single core FR cable (ISI marked) overall 1.5sq. mm, 1100 volts grade to be laid in heavy gauge PVC conduit pipe 20mm/ 25mm dia. (ISI Marked) recessed in wall etc., complete with powder coated/anodized concealed metal boxes (1.6mm thick with Brass lugs) required for suitable number of modules (Modular accessories) for having Step type electronic fan regulators (two module) 100watts, bell push, 6Amp. 2/3 universal socket (shuttered), 16/20Amp. combined/ universal Socket (shuttered), 6/10Amp. Switches, 16/20Amp. switches with indicator etc. and covered with Frame Plate etc., PVC connector (For Fan Box and Call Bell), Steel Hooks, Sheet metal fan box (1.6mm thick shape hexagonal), Circular junction Boxes (Four way PVC 1½" deep for walls and CI 3" deep for ceiling), bonding to earth with PVC insulated copper conductor single core FR cable (ISI marked) 1sq. mm, 1100volts grade (For 6Amp. wall socket & plug control point) and other petty material etc., including the cost of above material, cutting and filling up of chases (with finishing the surface):-Wiring fan point (With fan box)
Wiring light point
Wiring 6Amp. Plug control comprising wall socket point
Wiring 16/20Amp. power plug control point
Earthing with G.I. wire/ rope in G.I. pipe partly recessed and partly on surface complete with 150cm long 50mm dia. G.I. earth pipe (Cutting threads and 36 Nos. holes, 1cm dia. to make a mesh around the GI Pipe) and with G.I. reducing socket including erection of the same, 10.50 metre (34.44 feet) below ground level with 20Kg. charcoal & salt mixture etc., up to 14 metre in length (including boring & refilling). a)Earthing with 8 S.W.G. (4mm dia.) G.I. wire in 15mm dia G.I. pipe with G.I. reducing socket 50mm x 15mm (upto 14Metre in length)
Supply and erection of Miniature Circuit Breaker MCB's for circuit protection against overload and short circuit current fault suitable for 240/ 415 volts 50cycles AC supply with breaking capacity of 10kA, Curve-C and low watt losses as per IS/IEC 60898-1, energy limitation class-3, true contact indication, label holder facility in the existing MCB distribution board as per PWD General Specifications including connections with suitable size of thimbles/lugs:-a)MCB Single Pole 0.5-4 amp. (10kA, Curve-C)
Supply and erection of Miniature Circuit Breaker MCB's for circuit protection against overload and short circuit current fault suitable for 240/ 415 volts 50cycles AC supply with breaking capacity of 10kA, Curve-C and low watt losses as per IS/IEC 60898-1, energy limitation class-3, true contact indication, label holder facility in the existing MCB distribution board as per PWD General Specifications including connections with suitable size of thimbles/lugs:-b)MCB Single Pole 6-32amp. (10kA, Curve-C) (10kA, Curve-C)
Supply and erection of Miniature Circuit Breaker MCB's for circuit protection against overload and short circuit current fault suitable for 240/ 415 volts 50cycles AC supply with breaking capacity of 10kA, Curve-C and low watt losses as per IS/IEC 60898-1, energy limitation class-3, true contact indication, label holder facility in the existing MCB distribution board as per PWD General Specifications including connections with suitable size of thimbles/lugs:-c)MCB Double Pole 6-32amp. (10kA, Curve-C)
Wiring air conditioner supply terminal point recessed in wall etc., complete with powder coated/anodized concealed metal boxes required for suitable number of modules (Modular accessories) for having 25Amp. combined/ universal Socket (shuttered) and modular motor starter 25Amp. (2Module), covered with Frame Plate and other petty material etc. including the cost of above material, cutting and filling up of chases (with finishing the surface):- a)Wiring AC supply terminal point having 1No. 25Amp. universal Socket (shuttered) erected at AC height and 1No. Motor starter 25Amp. erected at switchboard height.
Supply and erection of TV socket, Telephone socket and Networking socket points in powder coated/anodized concealed metal boxes recessed in wall required for suitable number of modules (Modular accessories) for having TV sockets, Telephone sockets RJ11 & Networking socket RJ45 (one module), covered with Frame Plate and other petty material etc., including the cost of above material, cutting and filling up of chases (with finishing the surface):-a)Wiring Telephone socket point RJ11 (one module)
Supply and erection of TV socket, Telephone socket and Networking socket points in powder coated/anodized concealed metal boxes recessed in wall required for suitable number of modules (Modular accessories) for having TV sockets, Telephone sockets RJ11 & Networking socket RJ45 (one module), covered with Frame Plate and other petty material etc., including the cost of above material, cutting and filling up of chases (with finishing the surface)-b)Wiring Networking socket point RJ45 (one module)
Supply, laying and erection of aluminium conductor XLPE insulated PVC sheathed armoured and served cable 1100 volts grade as per IS 7098 (Part-1)1988 to be laid loose in the existing trench or pipe as per PWD General Specifications:- Overall size 10sq.mm (4Core) Armoured (Loose)
Supply & erection of Heavy guagewelded conduit pipe (ISI marked) as per IS:9537:Part-II for wiring purposes including bends, junction boxes, Steel hooks, GI saddle clamps and other petty materials etc., where necessary including painting as per PWD General specifications-Supply & erection of 19/20mm dia. M.S. conduit pipe (1.6mm thick), White painted suspension rod for ceiling fan.
Supply and erection of sheet metal Double Door Distribution Boards IP 43- IK09 metal door (dust protected) as per IS 8623-1&3, IEC 61439-1&3 suitable for flush mounting with fully insulated copper busbars, shrouded neutral bars, earth bars, cement spill protector, colorcoded interconnecting wire set, cable ties, blanking plates and circuit identifications label and of required no. of ways for mounting miniature circuit breakers/ RCBO's/ RCCB's in the distribution board (For SP&N distribution board with provision DP MCB's/ RCCB's/ RCBO's as incomer and SP MCB's as outgoings and for TP&N horizontal distribution board with provision TPN/ FP MCB's/ RCCB's/ RCBO's as incomer and SP MCB's as outgoings) as per PWD General specifications including connections with suitable size of thimbles and bonding to existing earth etc:- SP&N Horizontal Double Door Distribution Board 16 way each
Any Other Items
THE MOHAN KE UTTAR COOP L AND C SOCIETY LTD
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .