Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹19.0 CrAccepted-AOC | ₹19.0 Cr | L1 | Accepted-AOC Work Order Issued |
| 2 | L2₹19.3 CrRejected-Finance HARSH ANAND YEVALEKAR MALA COLLEGE ROAD NASHIK 422005 | NASHIK | NASHIK | MAHARASHTRA | 422005 | ₹19.3 Cr | L2 | Rejected-Finance Offer Rejected |
| 3 | L3₹19.4 CrRejected-Finance PLOT NO 3 YOGANAND CO OP HOUSING SOCIETY BEHIND BIJAN HOSPITAL NEAR MALPANNI HOSPITAL VIGHA MALA CANADA CORNER COLLEGE ROAD NASHIK | NASHIK | NASHIK | MAHARASHTRA | ₹19.4 Cr | L3 | Rejected-Finance Offer Rejected |
| 4 | Rejected-Technical B 4 RIDDHI PARK TILAKWADI CORNER SHARANPUR ROAD NASHIK | NASHIK | NASHIK | MAHARASHTRA | - | - | Rejected-Technical Disqualify |
| 5 | Rejected-Technical DURGA APT INDRA NAGAR NASHIK 422009 | NASHIK | NASHIK | MAHARASHTRA | 422009 | - | - | Rejected-Technical Disqualify |
Tender Value
₹17.3 Cr
EMD Value
₹8.6 L
Closing Date
5 Dec 2022, 5:00 pmClosed
Executive Engineer, PWD, Malegaon
Executive Engineer, PWD, Malegaon
Construction of 30 Bedded Rural Hospital and 25 Residential Quarters at Mulher, Tal. Satana, Dist. Nashik
2022_PWR_853078_1
Tender Notice No. 25 for 2022-2023
Open Tender
Civil Works - Buildings
730 days
Satana
Please refer Tender documents.
9 documents required · 9 mandatory
₹3,540
₹8.6 L
Chief Engineer, P.W. Region Nashik
27 May 2023
21 Nov 2022
6 Dec 2022
21 Nov 2022
5 Dec 2022
21 Nov 2022
28 Nov 2022
Amount
Clearing and grubbing road land including uprooting rank vegetation, grass, bushes, shrubs, saplings and trees girth up to 300 millimetre, removal of stumps of trees cut earlier and disposal of unserviceable materials and stacking of serviceable material to be used or auctioned up to a lead of 1000 metres including removal and disposal of top organic soil not exceeding 150 millimetre in thickness.
Excavation for foundation in earth, soil of all types, sand, gravel and soft murum, including removing the excavated material up to a distance of 50 m. beyond the building area and stacking and spreading as directed, dewatering, preparing the bed for the foundation and necessary back filling, ramming, watering including shoring and strutting etc. complete. (Lift upto 1.5 metre.) By Mechanical means
Excavation for foundation in hard murum including removing the excavated material upto distance of 50 metres beyond the building area and stacking and spreading as directed, dewatering, preparing the bed for the foundation and necessary back filling, ramming, watering including shoring and strutting etc. complete. (Lift upto 1.50 metre) By Mechanical means
Excavation for foundation in hard murum and boulders including removing the excavated material up to a distance 50 metres, beyond the building area and stacking and spreading as directed, dewatering, preparing the bed for the foundation and necessary back filling, ramming, watering including shoring and strutting etc. complete. (Lift upto 1.5metre) By Mechanical means
Excavation for foundation in Soft rock and old cement or lime masonry foundations including removing the excavated material upto a distance of 50 metres beyond the building area and stacking as directed, including dewatering, preparing the bed for the foundation and necessary back filling with available earth / murum, ramming, watering including shoring and strutting etc. complete (lift upto 1.5metre) By Mechanical means
Excavation for foundation in Hard rock by chiselling, wedging, line drilling, etc. including trimming and levelling the bed, removing the excavated material upto a distance of 50 metres beyond the building area stacking as directed, dewatering and back filling with available earth/ murum watering, ramming etc. complete. (Lift upto 1.5 metres). By Mechanical means
Providing and laying Cast in situ / Ready Mix cement concrete in M-10 of trap/ granite/ quartzite/ gneiss metal for foundation and bedding including bailing out water, formwork, laying/pumping, compacting, roughening them if special finish is to be provided, finishing if required and curing complete, with fully automatic micro processor based Programmable Logic Controller with Supervisory Control and Data Acquisition enabled reversible Drum Type mixer/concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand Vertical Shaft Impactor Grade etc)
Providing and laying Cast in situ / Ready Mix cement concrete in M-15 of trap/ granite/ quartzite/ gneiss metal for foundation and bedding including bailing out water, formwork, laying/pumping, compacting, roughening them if special finish is to be provided, finishing if required and curing complete, with fully automatic micro processor based Programmable Logic Controller with Supervisory Control and Data Acquisition enabled reversible Drum Type mixer/concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand Vertical Shaft Impactor Grade etc)
Filling in plinth and floors with approved excavated material in 15 centimetre to 20 centimetre layers including watering and compacting etc. complete. Spec. No. : Bd.A. 11/Page No. 262
Filling in plinth and floors with contractors material/brought from outside and approved by Engineer in charge in layers of 15 centimetre to 20 centimetre. including watering and compaction etc. complete. Spec. No. : Bd.A. 11/Page No. 263
Providing dry/ trap/ granite/ quartzite/ gneiss rubble stone soling 15 centimetre to 20 centimetre thick including hand packing and compacting etc. complete.
Providing and laying in situ / Ready Mix cement concrete M-25 of trap / granite /quartzite/ gneiss metal for Reinforced Cement Concrete work in foundations like raft, strip foundations, grillage and footings of Reinforced Cement Concrete columns and steel stanchions etc. including bailing out water, formwork, laying / pumping cover blocks, compaction and curing roughening the surface if special finish is to be provided (Excluding reinforcement and structural steel) etc. complete, with fully automatic micro processor based Programmable Logic Controller with Supervisory Control and Data Acquisition enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine Aggregate( Crushed sand/Vertical Shaft ImpactorGrade)
Providing and laying Cast in situ / Ready Mix cement concrete M-25 of trap / granite /quartzite/ gneiss metal for Reinforced Cement Concrete columns as per detailed designs and drawing or as directed including centering, formwork, cover blocks, laying/pumping, compaction finishing the formed surfaces with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening if special finish is to be provided and curing etc. complete,(Excluding reinforcement and structural steel).with fully automatic micro processor based Programmable Logic Controller with Supervisory Control and Data Acquisition enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine Aggregate( Crushed sand/Vertical Shaft ImpactorGrade) (A) Ground Floor
(B) First Floor
(C) Second Floor
(D) Third Floor
Providing and laying Cast in situ / Ready Mix cement concrete M-20 of trap / granite /quartzite/ gneiss metal for Reinforced Cement Concrete columns as per detailed designs and drawing or as directed including centering, formwork, cover blocks, laying/pumping, compaction finishing the formed surfaces with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening if special finish is to be provided and curing etc. complete,(Excluding reinforcement and structural steel).with fully automatic micro processor based Programmable Logic Controller with Supervisory Control and Data Acquisition enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine Aggregate( Crushed sand/Vertical Shaft ImpactorGrade) (B) First Floor
(C) Second Floor
(D) Third Floor
Providing and casting in situ cement concrete M-25 of trap / granite /quartzite/ gneiss metal for Reinforced Cement Concrete beams and lintels as per detailed designs and drawings or as directed including centering, formwork, cover blocks compaction and roughening the surface if special finish is to be provided and curing etc. complete. (Excluding reinforcement and structural steel), with fully automatic micro processor based Programmable Logic Controller with Supervisory Control and Data Acquisition enabled concrete batch mix plant (pan mixer). With fine Aggregate( Crushed sand/Vertical Shaft ImpactorGrade) (A) Ground Floor
(B) First Floor
(C) Second Floor
(D) Third Floor
Providing and laying Cast in situ / Ready Mix cement concrete M-25 of trap/ granite/ quartzite/ gneiss metal for Reinforced Cement Concrete chajja as per detailed design and drawings including centering, formwork, cover blocks compacting , curing , finishing and roughening the surface if special finish is to be provided and curing complete. (Excluding reinforcement and structural steel).with fully automatic micro processor based Programmable Logic Controller with Supervisory Control and Data Acquisition enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine Aggregate( Crushed sand/Vertical Shaft ImpactorGrade) (A) Ground Floor
(B) First Floor
(C) Second Floor
(D) Third Floor
Providing and laying Cast in situ/Ready Mix cement concrete M-25 of trap/ granite / quartzite/ gneiss metal for Reinforced Cement Concrete slabs and landings as per detailed designs and drawings including centering, formwork, cover blocks, laying/pumping, compactionfinishing the formed surfaces with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening if special finish is to be provided and curing etc. complete, (Excluding reinforcement and structural steel).with fully automatic micro processor based Programmable Logic Controller with Supervisory Control and Data Acquisition enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine Aggregate( Crushed sand/Vertical Shaft ImpactorGrade) (A) Ground Floor
(B) First Floor
(C) Second Floor
(D) Third Floor
Providing and laying Cast in situ/Ready Mix cement concrete in M-25 of trap/ granite/ quartzite/ gneiss metal for Reinforced Cement Concrete pardi of required thickness including centering, formwork, cover blocks, laying/pumping, compacting , curing , finishing and rougheningthem if special finish is to be provided and curing complete. (Excluding reinforcement and structural steel). with fully automatic micro processor based Programmable Logic Controller with Supervisory Control and Data Acquisition enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine Aggregate( Crushed sand/Vertical Shaft ImpactorGrade) (A) Ground Floor
(B) First Floor
(C) Second Floor
(D) Third Floor
Providing and laying Cast in situ / Ready Mix cement concrete in M-25 of trap / quartzite /granite /gneiss metal for Reinforced Cement Concrete Waist slab, and steps of staircases as per detailed design and drawings or as directed including steel centering, plywood/ steel formwork, steel props, laying / pumping, compaction, finishing uneven and honeycombed surface with Cement Mortor 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening the surface if special finish is to be provided and curing etc. complete. (Excluding einforcement, including cover block).(Newly laid concrete shall be covered by gunny bag, plastic, tarpaulin etc.) with fully automatic micro processor based Programmable Logic Controller with Supervisory Control and Data Acquisition enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine Aggregate( Crushed sand/Vertical Shaft ImpactorGrade) (A) Ground Floor
(B) First Floor
(C) Second Floor
(D) Third Floor
Providing and fixing during laying in Reinforced Cement concrete Slab rectangular 2 millimetre thick Mild Steel sheet fan hook box of size 180 X 100 millimetre with required depth with holes or notches as required, bottom and top sides of 1.6 millimetre Mild Steel sheet fixed with 3.5 millimetre diametre round headed screws together with 12 millimetre diametre Mild Steel bar bent to shape with hooked ends for fan hook and painting to exposed surface (A) Ground Floor
(B) First Floor
(C) Second Floor
(D) Third Floor
Providing and laying Cast in situ/Ready Mix cement concrete in M-20 of trap/ granite/ quartzite/ gneiss metal for Reinforced Cement Concrete coping to plinth or parapet and sill of doors and windows moulded as per detailed drawings or chamfered as approved by the Engineer including centering, formwork, cover blocks, laying / pumping, compacting, curing, finishing and roughening them if special finish is to be provided and curing complete. (Excluding reinforcement and structural steel). with fully automatic micro processor based Programmable Logic Controller with Supervisory Control and Data Acquisition enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine Aggregate( Crushed sand/Vertical Shaft ImpactorGrade) (A) Ground Floor
(B) First Floor
(C) Second Floor
(D) Third Floor
Providing and fixing in position Thermo Mechanically Treated - FE - 500 bar reinforcement of various diameters for Reinforced Cement Concrete pile caps, footings, foundations, slabs, beams columns, canopies, staircase, newels, chajjas, lintels pardis, copings, fins, arches etc. as per detailed designs, drawings and schedules. including cutting, bending, hooking the bars, binding with wires or tack welding and supporting as required complete. (A) Ground Floor
(B) First Floor
(C) Second Floor
(D) Third Floor
Providing and fabricating structural steel work in rolled sections like joists, channels, angles, tees etc. as per detailed design and drawings or as directed including cutting, fabricating, hoisting, erecting, fixing in position making riveted / bolted /welded connections without connecting plates, braces etc. and including one coat of anticorrosive paint and over it two coats of oil painting of approved quality and shade etc. complete. (A) Ground Floor
(B) First Floor
(C) Second Floor
(D) Third Floor
Providing fly ash brick masonry with conventional / Indian Standard type fly ash bricks in Cement Mortor 1:6 in foundation and plinth including bailing out water manually striking joints, racking out joints watering and scaffolding etc. complete.
Providing and constructing masonry in Autoclaved Areaclaved ( Celluar) Concrete Block of aproved manufacturer confirming to IS 2185 Part III 1984 of size ( 625x240x225) millimetre in extra fine jointing mortar of fixoblock of Ultra Tech or equivalent in foundaions and plinth of inner walls/in plinth external walls including bailing out water,striking joints on unexposed faces,racking out joints on exposed faces and watering etc.complete
Providing and constructing masonry in Autoclaved Areaclaved ( Celluar) Concrete Block of aproved manufacturer confirming to IS 2185 Part III 1984 of size ( 625x240x225) millimetre in extra fine jointing mortar of fixoblock of Ultra Tech or equivalent in superstucture including,striking joints,racking out joints watering and scaffolding etc.complete (A) Ground Floor
(B) First Floor
(C) Second Floor
(D) Third Floor
Providing and constructing masonry in Autoclaved Areaclaved (Celluar) Concrete Block of aproved manufacturer confirming to IS 2185 Part III 1984 of size (625x 240x100) millimetre in extra fine jointing mortar of fixoblock of Ultra Tech or equivalent in half brick thick wall including 2 hoop iron strips 25mm x 1.6mm at every third course,properly bend and bonded at ends scaffolding racking out joints and watering compete (A) Ground Floor
(B) First Floor
(C) Second Floor
(D) Third Floor
Providing internal cement plaster 6 millimetre thick in a single coat in cement mortar 1:3 without neeru finish to concrete surface in all positions including scaffolding and curing etc. complete. (A) Ground Floor
(B) First Floor
(C) Second Floor
(D) Third Floor
Providing internal cement plaster 12 millimeter thick in single coat in cement mortar 1:4 without neeru finish to concrete or brick surfaces, in all positions including scaffolding and curing etc. complete. (A) Ground Floor
(B) First Floor
(C) Second Floor
(D) Third Floor
Providing and applying plaster / wall punning with plaster of paris ( with plaster of paris material of Ambuja / Mor Chap or equivalent make ) in 10 to 13 millimeter thickness to previously plastered surface / or on newly brick surface ( Excluding rough cast plaster ) in all position including preparing and Finishing the surface scaffolding etc.complete. (A) Ground Floor
(B) First Floor
(C) Second Floor
(D) Third Floor
Providing and applying Two coats of wall care Putty on plastered surface and Ceiling and Walls to prepare surface even and smooth of approved make, etc complete. (A) Ground Floor
(B) First Floor
(C) Second Floor
(D) Third Floor
Providing waterproof plaster in Water Closet and bath 12 millimetre thick for dado in cement mortar 1:3 with neat finishing, floating using waterproofing compound at the rate of 1 kilogram per bag of cement of approved make and manufacturer and curing etc. complete. (Excluding Tiles) (As directed by Engineer in Charge) (A) Ground Floor
(B) First Floor
(C) Second Floor
(D) Third Floor
Providing neeru finish to plastered surfaces in all positions including scaffolding and curing etc. complete.
Providing internal cement plaster 20 millimetre thick in two coats in cement mortar 1:4 without neeru finish, to concrete, brick surface, in all positions including scaffolding and curing etc. complete.
Providing internal cement plaster 12millimetre thick in single coat in cement mortar 1:5 without neeru finish to concrete or brick surfaces, in all positions including scaffolding and curing etc. complete. (A) Ground Floor
(B) First Floor
(C) Second Floor
(D) Third Floor
Providing sand faced plaster externally in cement mortar using approved screened sand, in all positions including base coat of 15 millimetre thick in cement mortar 1:4 using waterproofing compound at 1 kilogram per cement bag curing the same for not less than 2 days and keeping the surface of the base coat rough to receive the sand faced treatment 6 to 8 millimetre thick in cement mortar 1:4 finishing the surface by taking out grains and curing for fourteen days scaffolding etc.complete. (A) Ground Floor
(B) First Floor
(C) Second Floor
(D) Third Floor
Providing and applying Texture plaster with finishing with texture material of approved make in 3 to 4 millimeter thickness on previously finished plastered surface including Plaster Groove 6 millimeter thickness or Tape Grooves 35 to 45 millimeter thickness or as required, in all position including preparing the surface scaffolding etc.complete. (A) Ground Floor
(B) First Floor
(C) Second Floor
(D) Third Floor
Providing fine cement finish 1.5 millimetre thick over green plaster surface including scaffolding curing etc. complete.
Providing patti/ band 150 millimetre wide on plastered surface 12 millimetre to 15 millimetre thick in Cement Mortor 1:3 line and level including neat finishing scaffolding curing etc. complete. (A) Ground Floor
(B) First Floor
(C) Second Floor
(D) Third Floor
Providing and fixing chicken mesh of 22 gauge, with about 30 centimetre width at the junction of Rrinforced Cement Concrete members and brick work, of approved quality including fixing mesh in position by necessary drilling in concrete / Burnt Brick masonry and or tying by binding wire etc. complete.
Labour charges for providing groove in external plaster having width and spaced as directed by engineer incharge etc. complete. (A) Ground Floor
(B) First Floor
(C) Second Floor
(D) Third Floor
Providing and applying required coats of a water based Evercrete Deep Penetrating Sealer (DPS) on cement concrete surface like roads, beams, and columns, plastered walls, basements, roofs, potable water tanks etc to react with cement and to penetrate concrete structure thereby making it resistant to chemicals / chlorides water to make it dust proof and to act as a water resistant at the same time which Strengthens the treated surface and reduce the curing period etc complete.
Providing and laying Polished Kota stone flooring With Hand-Cut Polished Kota Stones 25 millimetre to 30 millimetre thick and required width in plain/diamond pattern on bed of 1:6 Cement mortar including cement float, filling joints with neat cement slurry, curing, cleaning and Mirror Polishing etc. complete Note- Water absorption for kota stone should not exceed 0.05%. (A) Ground Floor
(B) First Floor
(C) Second Floor
(D) Third Floor
Providing and laying vitrified matt fininsh tiles having size 590 millimetre to 605 millimetre x to 605 millimetre of 8 to 10 millimetre thickness and confirming Indian Standard 15622-2006 (Group Bla) of approved make, shade and pattern for flooring in required position laid on a bed of 1:4 cement morar including neat cement float, filling joints, curing and cleaning etc. complete. a) Flooring (A) Ground Floor
(B) First Floor
Providing and laying vitrified mirror / glossy finish tiles decorative type make having size 590 millimetre to 605 millimetre x 590 millimetre to 605 millimetre of 8 to 10 millimetre thickness and confirming to Indian Standard. 15622-2006 ( group Bla) of approved make, shade and pattern for flooring in required position laid on a bed of 1:4 cement mortar including neat cement float, filling joints, curing and clearing etc. complete, a) Flooring (B) First Floor
(C) Second Floor
Providing and laying in position flooring of telephone black / Amba White / Cat bary brown / Ruby red / Ocean Brown granite stone of approved shade and size 18 millimetre to 20 millimetre thick on bed 1:6 cement mortar including cement floats striking joints, pointing in Cement Mortor 1:3 curing and cleaning etc. complete. (A) Ground Floor
(B) First Floor
(C) Second Floor
(D) Third Floor
Providing and laying Polished Tandur Stone flooring 25 millimetre to 30 millimetre thick required width in plain/ diamond pattern on a bed of 1:6 Cement Mortor including cement float, filling joints with neat cement slurry, curing, polishing and cleaning etc. complete.
Providing and laying in situ / ready mix M-20 cement concrete of trap /granite /quartzite /gneiss metal for approach slab / Rigid pavement including compacting, finishing, curing etc. complete. (excluding reinforcement) (with reversible drum type mixer/ concrete batch mix plant (pan mixer) with Supervisory Control and Data Acquisition with fine agreegates of required specifications (Natural sand / Vertical Shaft Impactor sand finely washed etc ), cement 6.40 bags/cumt)
Providing and laying in situ cement concrete M30 with tremix treatment for 200 millimetre thickness for flooring with groove cutting of 4 millimetre wide and 20 millimetre deep with necessary refilling with bitumen etc. complete.
Providing and laying Antiskid Ceramic tiles of approved quality of size 30 centimetre x 30 centimetre and confirming to IS 15622-2006 (Group-B IIA) for antiskid flooring in required position laid on a bed of 1:4 cement mortar including cement float, filling joint with cement slurry cleaning curing etc. complete. (A) Ground Floor
(B) First Floor
(C) Second Floor
(D) Third Floor
Providing and fixing in required position skirting or dado of polished Kotah Stone slab 25 millimetre to 30 millimetre thick fixed on base on plaster of cement mortar 1:4 including cement float, filling joints with cement slurry, curing rubbing, polishing and cleaning complete. (A) Ground Floor
(B) First Floor
(C) Second Floor
(D) Third Floor
Providing and laying vitrified mirror / glossy finish tiles having size 590 millimeter to 605 millimeter x 590 millimeter to 605 millimeter of 8 to 10 millimeter thickness and confirming to IS. 15622-2006 ( group Bla) of approved make, shade and pattern for dado and skirting in required position laid on a bed of 1:4 cement mortar including neat cement float, filling joints, curing and clearing etc. complete.b) Skirting (B) First Floor
(C) Second Floor
Providing and laying ceramic tiles of having size 30 centimetre x 30 centimetre and confirming to corresponding Indian Standard for dado and skirting in required position with readymade adhesive mortar of approved quality on plaster of 1:2 cement mortar including joint filling with white/ colour cement slurry cleaning curing etc. complete. (A) Ground Floor
(B) First Floor
(C) Second Floor
(D) Third Floor
Providing and laying vitrified matt finish tiles having size 590 millimetre to 605 millimetre x to 605 millimetre of 8 to 10 millimetre thickness and confirming IS. 15622-2006 (Group Bla) of approved make, shade and pattern fordado and skirting in required position laid on a bed of 1:4 cement mortar including neat cement float, filling joints, curing and cleaning etc. complete. b) Skirting (A) Ground Floor
(B) First Floor
Providing and laying telephone black / Amba White / Cadburybrown / Ruby red / Ocean Brown granite stone of 18 to 20 millimetre thick for door frame/ dado/ window boxing etc. on Cement Mortor 1:6 including filling joints with polymer base filler nosing the sharp edges wherever necessary, curing, etc. complete. (A) Ground Floor
(B) First Floor
(C) Second Floor
(D) Third Floor
Providing and fixing machine cut machine polished 18 millimetre to 20 millimetre thick telephone black / Amba White / Cat bary brown / RBI red / Ocean Brown granite stone for treads and risers of steps and staircases of approved colour and shade with rounded moulding and three grooved line for the treads on bed of 1:4 Cement mortar including float filling joints with neat cement slurry curing polishing and cleaning etc. complete. (A) Ground Floor
(B) First Floor
(C) Second Floor
(D) Third Floor
Providing and applying priming coat on concrete/ masonary/ Asbestos Cement plastered surfaces including scaffolding if necessary, preparing the surface by thoroughly cleaning oil, grease, dirt and other foreign matter and sand papering as required etc. complete. (A) Ground Floor
(B) First Floor
(C) Second Floor
(D) Third Floor
Providing and applying plastic emulsion paint of approved quality, colour and shade to old and new surfaces in two coats including scaffolding, preparing the surface, (excluding the primer coat)etc. complete. (A) Ground Floor
(B) First Floor
(C) Second Floor
(D) Third Floor
Providing and applying two coats of exterior acraylic emulsion paint confirming to corresponding Indian Standard of approved manufacture and of approved colour to the plastered surfaces including cleaning, preparing the plaster surface, applying primer coat, scaffolding if necessary, and watering the surface for two days etc complete. (A) Ground Floor
(B) First Floor
(C) Second Floor
(D) Third Floor
Providing and applying two coats of textured synthetic paint of approved shade and quality and one coat of primer before applying textured paint including scaffolding if necessary preparing surface by thoroughly cleaning oil, grease, dirt and other materials as required, etc. complete. (A) Ground Floor
(B) First Floor
(C) Second Floor
(D) Third Floor
Providing and applying melamine polish of required finish to the wood work by spray machine including knotting and preparing the even surface by scraping, applying French polish , scaffolding if required etc. complete. Note:The work to be executed on prior approval of Superintending Engineer will be necessary. (A) Ground Floor
(B) First Floor
(C) Second Floor
(D) Third Floor
Providing and fixing Indian Standard Institute marked double swing flush door shutters conforming to IS :2202 (Part I) Non-decorative type, core of block board construction with frame of 1st class hard wood and well matched teak 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters. 30 milimetre thick including Indian Standard Institute marked Stainless Steel L- hinges with necessary screws Fittings & Fixtures per leaf Stainless Steel kick plates on both sides of the door of 300milimetre height Heavy Duty satin finish butt SS Hinges (100 milimetre x 75 milimetre x 3 milimetre in size) -4 Numbers Stainless Steel finished lever handle with mortise lock- 1 Number Floor spring- 1 Number 100 milimetre x 100 milimetre safety glass at the specified location (A) Ground Floor
Providing and fixing M-40 grade thick vibrated pull cast or similar type concrete frame with chamfer conforming to IS. 6524-1983 having 6 millimetre diametres bars 3 Numbers And stirrups @ 250 millimetre centre to centre and fixing in wall with 6 Numbers of hold fast of 12 millimetre diametre bars 500 millimetre long including primer and oil painting etc, complete) frame size 60 millimetre x 100 millimetre. (A) Ground Floor
(B) First Floor
(C) Second Floor
(D) Third Floor
Providing and fixing M-40 grade thick vibrated pull cast or similar type concrete frame with chamfer conforming to IS. 6524-1983 having 6 millimetre diametres bars 3 Numbers And stirrups @ 250 millimetre centre to centre and fixing in wall with 6 Numbers of hold fast of 12 millimetre diametre bars 500 millimetre long including primer and oil painting etc, complete) frame size 60 millimetre x 100 millimetre. (A) Ground Floor
(C) Second Floor
(D) Third Floor
Providing and fixing solid core flush door shutter in single leaf 32 millimetre thick decorative type of exterior grade as per detailed drawings approved face veneers 3 millimetre thick on both faces or as directed, all necessary beads, mouldings and lipping, wrought iron hold fasts, chromium plated fixtures and fastenings, with brass mortise lock, chromium plated handles on both sides, and finishing with French Polish etc. complete. (A) Ground Floor
(B) First Floor
(C) Second Floor
(D) Third Floor
Providing and fixing solid core flush door shutter in double leaf 32 millimetre thick decorative type of exterior grade as per detailed drawings approved face veneers 3 millimetre thick on both faces or as directed, all necessary beads, mouldings and lipping, wrought iron hold fasts, chromium plated fixtures and fastenings, with brass mortise lock, chromium plated handles on both sides, and finishing with French Polish etc. complete. (A) Ground Floor
(B) First Floor
(C) Second Floor
(D) Third Floor
Providing and fixing in position, Double shuttered aluminium extruded powder coated openable door of specified size with aluminium door frame of powder coated section 101.60 x 44.75 millimetre, 3.18 millimetre thick and shutter comprising of powder coated section having bottom and lock rail of size 150 millimetre x 44.5 millimetre x 3.00 millimetre thick top rails 47.62 x 44.45 millimetre x 3.00 millimetre thick , vertical style 47.62 x 44.45 millimetre, 3.00 millimetre thick and for shutter plain glass panes 5 millimetre thick for top panels and 12 millimetre thick both side laminated phenol bonded particle board panels for bottom panels etc. , Indian Standard Institute mark , heavy duty, Hydraulic floor spring of 150 kilogram capacity , having heavy duty concealed lock, necessary beading, glazing clips, Poly Vinyl Chloride gaskets, 250 millimetre length aluminium tower bolts, 150 millimetre diametre pad handle, etc. as per detailed design and drawing or as directed by engineer in charge including all materials , labours, and equipment etc.complete (A) Ground Floor
Providing and fixing fiber glass reinforced polyster door shutter 30 millimetre thick as per IS 14856 (2000) (Reaffirmed 2006) without ventilator including chromium plated fixtures and fastening with chromium plated handles on both sides, etc complete (A) Ground Floor
(B) First Floor
(C) Second Floor
(D) Third Floor
Providing and fixing rolling shutter fabricated from steel laths of minimum thickness 0.9 millimetre with lock plate of 3.15 millimetre thickness reinforced with 35 x 35 x 5 millimetre angle section fitted with sliding bolts and handles for both sides, deep Mild Steel channel section of depth and thickness not less than 65 millimetre and 3.15 millimetre respectively with hold fast arrangements, Mild Steel Bracket plate 300 x 300 x 3.15 millimetre minimum size and shape with square bar, suspension shaft of minimum 32 millimetre diameter, hood cover of Mild Steel sheet not less than 0.9 millimetre thickness and of any size at top and safety devices including mechanical gear operation arrangement consisting of worm gear wheels and worms of high grade cast iron or mild steel and one coat of red lead primer etc. complete. (Indian Standard. 62481979) (Without mechanical gear)
Providing and fixing collapsible steel gate in one / two leaves with hot rolled vertical channels of 18 x 9 x 3 mm minimum size, crossings of M.S. flats of size 18 x 5 mm T or E section for runner of minimum 40 x 6 mm size for flange, M.S. flat for top runner of minimum size 40 x 12 mm with roller wheels confirming to grade F.G. 150 fitted with snap headed rivets of minimum size 6 mm max. spacing of vertical channels be 100 mm enclosed gate position and clear space of 150 mm between two sets of crossings with hold fasts, stoppers, spaces, handles, locking arrangement and one coat of red lead primer and oil painting etc. complete. (I.S. 105211983). (A) Ground Floor
(B) First Floor
(C) Second Floor
(D) Third Floor
Providing and fixing sheet glass of 24 oz. for all size including putty etc. Complete (A) Ground Floor
(B) First Floor
Providing and fixing mild Steel grill door 24 kilogram per squaremetre of various size as per detailed drawings without hot dip coating, iron fixtures and fastenings and 3 coats of oil painting etc. (A) Ground Floor
Providing and fixing in position (as per 1868 / 1982) Aluminium sliding window of three tracks with rectangular pipe 95 X 38.10 X 0.90 millimetre at weight 0.637 kilogram per Running metre. with window frame bottom track section 92 X 31.75 X 1.30 millimetre at weight 1.070 kilogram per Running metre. Top and side track section 92 X 31.75 X 1.30 millimetre at weight 0.933 kilogram per Running metre. The shutter should be of bearing bottom 40 X 18 X 1.25 millimetre at weight 0.417 kilogram per Running metre. Inter locking section 40 X 18 X 1.10 millimetre at weight 0.469 kilogram per Running metre. and handle and top section 40 X 18 X 1.25 millimetre at weight 0.417 kilogram per Running metre. As per detailed drawings and as directed by Engineer in charge with all necessary Aluminium sections fixtures and fastenings such as roller bearing in nylon casting and self locking catch fitted in vertical section of shutter including 5 millimetre thick plain glass and aluminium mosquito net shutter with stainless steel jail with all required screws and nuts etc, complete. With powder coating without box (A) Ground Floor
(B) First Floor
(C) Second Floor
(D) Third Floor
(B) First Floor
Providing and fixing in position, Single shuttered aluminium extruded powder coated openable door of overall size 0.90 metre x 2.40 metre with aluminium door frame of powder coated section 101.60 x 44.75 millimetre, 3.18 millimetre thick and shutter comprising of powder coated section having bottom and lock rail of size 150 millimetre x 44.5 millimetre x 3.00 millimetre thick top rails 47.62 x 44.45 millimetre x 3.00 millimetre thick, vertical style 47.62 x 44.45 millimetre, 3.00 millimetre thick and for shutter plain glass panes 5 millimetre thick for top panels and 12 millimetre thick both side laminated phenol bonded particle board panels for bottom panels etc., Indian Standard Institute, mark , heavy duty, Hydraulic floor spring of 150 kilogram capacity, having heavy duty concealed lock, necessary beading, glazing clips, Poly Vinyl Chloride gaskets, 250 millimetre length tower bolts, 150 millimetre diagram pad handle, etc. as per detailed design and drawing or as directed by engineer in charge including all materials , labours, and equipment etc. Complete (B) First Floor
Providing and fixing in position powder coated aluminium louvered windows / ventilator of various sizes with powder coating as per detailed drawing and specifications including aluminium frames 80 x 38 millimetre x 1.22 millimetre box type, 5 millimetre thick sheet glass louvers, of approved quality etc. complete. (A) Ground Floor
(B) First Floor
(C) Second Floor
(D) Third Floor
Providing and fixing mild steel grill work for windows, ventilators etc. 20 kilogram per squaremetre as per drawing including fixtures, necessary welding and painting with one coats of anticorrosive paint and two coats of oil painting complete. (A) Ground Floor
(B) First Floor
(C) Second Floor
(D) Third Floor
Providing and fixing in position after hoisting, precast 1:2 cement mortar reinforced jali 80 millimetre thick with 3 millimetre diameter mild steel bar reinforcement, of approved design on both sides, fixing in cement mortar 1:3 and curing etc .complete.
Providing and fixing in position Gypsum board false ceiling with 12.5 millimeter thick Gypsum boards, screwed / fixed to the under structure of suspended Galvanised Iron Grid constructed and suspended from the main ceiling consisting of ceiling sections of size 25 x 50 millimeter maximum center to center distance of 600 milimetre perimeter channel and intermediate channels at maximum center to center distance 1200 milimetre galvanized grid should be fixed to reinforced cement concrete slab. The gypsum board should be fixed to galvanized iron grid with necessary screws. The boards should be taped and filled from underside to give smooth, seamless ceiling. The rate should include necessary additional ceiling sections and intermediate channels. Additional intermediate channels should be fixed to strap hangers for additional support to prevent strapping at every 1200 milimetre item to be completed in all respect including necessary sleeves for ducts finishing of joints cut outs, painting including labour, material, lifts etc. all complete. (A) Ground Floor
(B) First Floor
Providing and fixing false ceiling with eco-friendly light-weight calcium silicate tiles of spintone surface texture aerolite make or equivalent of size 595 millimetre x 595 millimetre having 15 millimetre thick densified micro look edge and 100% humidity resistance incombustible as per BS 46part IV and thermal conductivity 0.043 w/m 0 KC and NRC 0.50 placed in true horizontal level suspended grid of size 600x600mm made from hot dipped G.I. steel sections ion silhouette profile, rotary stitched double webbed white with 6mm reveal profile (white/black), wherein, main T runner of size 42 millimetrex14 millimetre between main tee 600 millimetre center-tocenter and secondary cross T of size 33x14x0.43 millimetre thick of length 600 millimetre long spaced inter-locked at middle of the first crossed T in each panel to form grid of 1200 millimetrex600 millimetre resting on periphery wall Profile wall section 19 millimetre (7+7) x 19 millimetre x 0.40thicknesses and laying false ceiling for services like diffusers grills including cutting, making opening for light fittings, fixtures, , smoke detectors etc., wherever required. Main T runners suspended from ceiling with using Galvanised Iron soffit cleats of size 25x35x1.6 millimetre of required length fixed to the ceiling with 6 millimetre diametre and 50 millimetre long dash fastener, 4 millimetre dia Galvanised Iron adjustable rods with powder-coated/good quality Galvanised Iron level adjustment clips of 35x35x0.8 millimetre spaced @1200, center-to-center along main T all complete at all heights as per the specifications, drawings and as per the directions of Engineer-in-charge. (A) Ground Floor
Providing and constructing granite kitchen platform with fixing of stainless steel sink 600 millimetre x 450 millimetre size as per detailed drawing including vertical both side polished kadappah stone 25 to 30 millimetre thick supports with kadappah top 35 to 40 millimetre thick and polished granite 16 to 20 millimetre top with side strips of granite at front and both sides of platform raised with two vertical granite supports 15 centimetre height and top granite of 75 x 40 centimetre including cutting, opening for sink of required size in kadappah as well as granite etc. complete. (B) First Floor
(C) Second Floor
(D) Third Floor
Providing and fixing black kadappa stone shelves 25 millimetre thick machine polished, extending the polish upto 20 centimeter width on lowerside, rounding comers, laying in position jointing with bedding cement mortar 1:4 proportion curing etc complete. (A) Ground Floor
(B) First Floor
(C) Second Floor
(D) Third Floor
Providing and Fixing mat finish stainless steel (of 302 grade ) railing with top pipe of 50 millimetre diametre and vertical pipe of 38 millimetre diametre at 0.60 metre centre to centre or as required and horizontal pipes of 25 millimetre diametre in three rows, all pipes of 2 millimetre thick including buffing,fabricating fixtures and fastening including pipe base of appropriate diameter and ball base of 75 millimetre diametre above newel post of 75 millimetre diameter etc. complete (Prior approval of sample and brand by Ex. Engineer is necessary before use) (A) Ground Floor
(B) First Floor
(C) Second Floor
(D) Third Floor
Providing preconstructional antitermite treatment as per Indian Standard. 6313 (Part-II) by treating the bottom surface and sides of excavation at the rate of 5 litres of emulsion concentrate of 1.0 percent of chlorophyrifos per square meter of surface area covering 10 years guarantee on bond paper.
Providing antitermite treatment around the periphery of the existing building as per Indian Standard 6313 (Part-Hi) by excavating trenches of 20 centimeter width and exposing the sides of columns and plinth beams upto a depth of 300 millimetre and injecting one percent of chlorodane emulsion concentrate at the rate of 2.25 litres per Rmt and refilling the trenches etc. complete covering 2 years guarantee on bond paper.
Providing preconstructional antitermite treatment as per Indian Standard 6313 (Part-II) by treating the top surface of plinth filling at the rate of 5 litres of emulsion concentrate at 0.5 percent of clorophyrifos per square metre of surface area covering ten years guarantee on bond paper. ( AS per Item no. 22.43 of schedule of rates of NBO )
Providing and fixing Galvanised Iron Pre coated trapezoidal Metallic coloured sheets of 0.50 millimetre thickness (26 Britian Wire Gauge) of approved make for roofing without wind ties including fastening with galvanised iron screws and bolts and lead and bitumen washers as per drawing complete. Spec. – As directed by Engineer-in-charge. (A) Ground Floor
(B) First Floor
(C) Second Floor
(D) Third Floor
Kitchen Trolley Providing and Fixing stainless steel kitchen trolley of overall 26 " height and 22" depth,supported on aluminium pipes ,trolley basket made out of 5 millimetre stainless steel rod fitted on telescopic channel of size 1.5 " x 20 " x 22 " on both sides of trolley of 12 " or above size, panel having 40 kg load bearing capacity of trolley made out of 20 millimetre PUC coated plywood and colour combination as directed by E-I-C.Inner side of panel covered by white mica ,100 millimetre s.s. decorative handle.(The width and height of individual compartments shall be kept as directed by Engineer-in-charge) (A) Ground Floor
(B) First Floor
(C) Second Floor
(D) Third Floor
Providing cement based water proofing treatment to terraces (Indian water proofing or alike) with brick bats laid in required slope to drain the water for any span after cleaning the base surface. Applying a coat of cement slurry admixed with approved water proofing compound and laying the brick bats on bottom layer in Cement Mortor 1:5 admixed with approved water proofing compound filling up to half depth of brick bats, curing this layer for 3 days, applying cement slurry over this layer joints of brick bats with Cement Mortor 1:3 admixed with approved water proofing compound and finally top finishing with average 20 millimetre thick layers of same mortar added with jute fiber at 1 Kilogram per bag including finishing the surface smooth with cement slurry admixed with approved water proofing compound. Marking finished surface with false squares of 300 millimetre X 300 millimetre making the junctions at the parapet rounded and tapered top for required height, with drip mould at the junction of plaster and parapet and curing and covering 10 years Guarantee against leakproofness on Court fee stamp paper of Rupees 500/- including ponding test etc. complete. (A) Ground Floor
(B) First Floor
(C) Second Floor
(D) Third Floor
Supply and Installation of translucent roof with DPI Flux standing seam multicell polycarbonate panel system. The system with complete assembly of co extruded Ultra Voilet protected multicell panels incorporated into a complete system. Co-extruded Ultra Voilet protected polycarbonate panel system of min 12 millimetre thick of 900 millimetre (minute.) width with angular daylighting concept. Panels shall have minimum six layers with truss bridge design for higher flexibility & strength. Panels with all fixing accessories to ensure best performance for wind uplift, vibration, oil canning and visual appearance. Panels shall be manufactured with vertical standing seam at both sides of the panel. Panels shall be fixed on Purlin with snap on connectors with double tooth grip lock locking mechanism and will be secured on Mild Steel structure (will be paid Separately) with 3 numbers self-drilling screws & trapezoid SS fasteners holding the base of the standing seam offering best stability having a pull-out load of min. 7000N (7Kilo Netwon) tested as per ISO 6892:1998 and IS 1608: 2005, as per design requirement. Panels must satisfy Dart drop impact test as per IS 14443-97 shall show no sign of breakage on Polycarbonate sheets which have been exposed to UV for a min. of 500 Hours as per ASTM G 155. Panels shall not have Yellowness Index as per ASTM D 1925 of 15 units when tested on a sample exposed to UV for 500 Hours as per ASTM G 155. U value shall not be more than 1.6 W/m2K as per EN ISO 10077-2:2018.
Providing waterproofing in Water Closet and bath including brick bat coba in all position including providing and laying 12 millimetre bedding in cement mortor 1:3 on vergin concrete slab with waterproofing compound @ 1 kilogram per bag of cement laying brick bat coba of required thickness in cm 1:5 with waterproofing compound 1 kilogram per bag of cement grouting and finishing the top layer with 20 millimetre thick brick bedding in cm mortor 1:3 with waterproofing compound 1 kilogram per bag of cement and testing the treated portion for 48 hours by pond test and covering ten years' guarantee on requisite stamp paper including curing etc. complete. (A) Ground Floor
(B) First Floor
(C) Second Floor
(D) Third Floor
Providing and laying in trenches 15 millimetre diametre Chlorinated Poly Venyl Chloride pipe including necessary excavation, fittings. Refilling trenches etc. complete Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete.
Providing and laying in trenches 20 millimetre diametre Chlorinated Poly Venyl Chloride pipe including necessary excavation, fittings. Refilling trenches etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete.
Providing and laying in trenches 25 millimetre diametre Chlorinated Poly Venyl Chloride pipe including necessary excavation, fittings. Refilling trenches etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete.
Providing and laying in trenches 32 millimetre diametre Chlorinated Poly Venyl Chloride pipe including necessary excavation, fittings. Refilling trenches etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete.
Providing and laying in trenches 40millimetre diametre Chlorinated Poly Venyl Chloride pipe including necessary excavation, fittings. Refilling trenches etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete.
Providing and fixing on walls/ceiling/floor 15 millimetre diametre Chlorinated Poly Venyl Chloride pipe with necessary fittings, remaking good the demolished portion etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete. (A) Ground Floor
(B) First Floor
(C) Second Floor
(D) Third Floor
Providing and fixing on walls/ceiling/floor 25 millimetre diametre Chlorinated Poly Venyl Chloride pipe with necessary fittings, remaking good the demolished portion etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete. (A) Ground Floor
(B) First Floor
(C) Second Floor
(D) Third Floor
Providing and fixing on walls/ceiling/floor 25 millimetre diametre Chlorinated Poly Venyl Chloride pipe with necessary fittings, remaking good the demolished portion etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete. (A) Ground Floor
(B) First Floor
(C) Second Floor
(D) Third Floor
Providing and fixing on walls/ceiling/floor 32 millimetre diametre Chlorinated Poly Venyl Chloride pipe with necessary fittings, remaking good the demolished portion etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete. (A) Ground Floor
(B) First Floor
(C) Second Floor
(D) Third Floor
Providing and fixing on walls/ceiling/floor 40 millimetre diametre Chlorinated Poly Venyl Chloride pipe with necessary fittings, remaking good the demolished portion etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete. (A) Ground Floor
(B) First Floor
(C) Second Floor
(D) Third Floor
Providing and fixing on walls/ ceiling/ floors, 80 millimetre diametreheavy grade having embossed as ISI Mark galvanised iron pipes weight of 10.15 Kilogram per meter with necessary fittings. and remaking good the demolished portion and applying primer of anti-corrosive oil paint 2 coats Including necessary scaffolding and removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete.
Providing and fixing on walls/ ceiling/ floors, 100 millimetre diametreheavy grade having embossed as ISI Mark galvanised iron pipes weight of 14.74 Kilogram per meter with necessary fittings. and remaking good the demolished portion and applying primer of anti-corrosive oil paint 2 coats Including necessary scaffolding and removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete.
Providing and making ISI Mark ferrule connection of 32 millimetre diametre to water main including ferrule coupling cast iron bell mouth cover, built in non return valve and fixing including excavation and reinstatement complete.
Providing, laying and fixing Poly Vinyl Chloride pipe of 110 millimetre diametre with fittings such as bends, tees, reducers, clamps, etc. including necessary excavation, trench filling etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete. (A) Ground Floor
(B) First Floor
(C) Second Floor
(D) Third Floor
Providing and fixing Poly Vinyl Chloride Rain water pipes of 110millimetre outer diameter and having wall thickness of 2.2 to 2.7 millimetre confirming to Indian Standard. 13592-1992 including proper rainwater receiving recess with Poly Vinyl Chloride. plug, bend, necessary fittings, such as, offsets, shoes, inluding fixing the pipe on wall using approved wooden cleats projecting 25millimetre to 40millimetre from face of wall a fixing with clips of approved quality and number ,filing the joint using rubber gasket with solvent cement and properly resting the shoe of pipes on Cement.Concrete. or masonry blocks, including necessary scaffolding and maintenance for 3 years for any leakages or dislocations of pipes. All the Poly Vinyl Chloride. fittings and additional 2 piece socket clips shall be got approved from engineer in charge etc. complete. (The contractor shall give 3 yrs guarantee bond for payment) (A) Ground Floor
(B) First Floor
(C) Second Floor
(D) Third Floor
Providing, laying and fixing Poly Vinyl Chloride pipe of 75 millimetre diametre with fittings such as bends, tees, reducers, clamps, etc. including necessary excavation, trench filling etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete. (A) Ground Floor
(B) First Floor
(C) Second Floor
(D) Third Floor
Providing and fixing 15 millimetre diameter screw down bib/ stop tap of brass including necessary socket union nut complete. (A) Ground Floor
(B) First Floor
(C) Second Floor
(D) Third Floor
Providing and fixing 15mm diameter concussion push button type brass/gun metal self-closing tap including necessary socket complete. (A) Ground Floor
(B) First Floor
(C) Second Floor
(D) Third Floor
Providing and fixing screw down 15 millimetre diameter wheeled stop tap of brass including necessary sockets/union nut complete (A) Ground Floor
(B) First Floor
(C) Second Floor
(D) Third Floor
Providing and fixing screw down for 25 millimetre diameter wheeled stop tap of brass including necessary sockets/union nut complete. (A) Ground Floor
(B) First Floor
(C) Second Floor
(D) Third Floor
Providing and fixing 10 centimetre Poly Venyl Chloride nahani trap with grating etc. complete. (A) Ground Floor
(B) First Floor
(C) Second Floor
(D) Third Floor
Providing and fixing 25millimetre diameter water meter with non-return valve including strainer, sockets/ union nut and including water meter box making locking arrangement and lock. [Without chamber].
Providing and fixing 1st class white glazed earthenware Orissa Type Water Closet Pan 580 millimetre diametre including P or S trap cast iron soil and vent pipe upto the outside face of the wall (1:5:1 0) cement concrete bedding 15 mm thick, 10 liter Poly Vinyl Chloride flushing cistern with all necessary pipe connection etc. complete. (A) Ground Floor
(B) First Floor
(C) Second Floor
(D) Third Floor
Providing and fixing white european type wall-hung, of size 360 millimetre X 360 millimetre X 575 millimetre with flush valve of approved make including soil pipe, vent pipe upto outside face of wall, 100 millimetre diametre Cast Iron plug bend inlet pipe all fittings,cutting and making good walls, floors etc as directed by Engineer in charge. (A) Ground Floor
(B) First Floor
Providing and fixing White Glazed Earthenware full stall type Urinal with Poly Vinyl Choride flushing cistern of 5 liters capacity with fitting, inlet pipes and stop tap, brackets for fixing the cistern, 32 millimetre diametre Poly Vinyl Choride flush pipe with fittings and flushing arrangement including lead soil pipe, lead trap, soil pipe connection up to the outside face of the wall (A) Ground Floor
Providing and Fixing toilet set for differently Abled persons consist of Floor Mounted white vitreous china water Closet including 6 litre capacity white vitreous china flushing Cistern with raised soft-push button, white vitreous china wash basin of size 46 x 36 centimetre and one no SS 304 hinged rail 76 centimetre & three no Stainless Steel 304of (Grab Bar) 60 centimetres all including cutting and making good the walls and floors wherever required ,seat cover, cistern & wash basin fittings,nuts, bolts and gasket etc complete of make Hindware(Matrix series 70002)/ Cera or equivalent as per the direction of Engineer-In-charge. (A) Ground Floor
Providing and fixing wall hung white wash basin of size 350 X 450 X 165 millimetre with approved make pillar cock, Chromium Plated Angular stop cock long thread approved make continental including Stainless Steel bottle trap of approved make having necessary pipe connection up to the outside face of the wall etc complete as directed by Engineer in charge. (A) Ground Floor
(B) First Floor
(C) Second Floor
(D) Third Floor
Providing and fixing chromium plated towel rod 16 millimetre diametre and 75 centimetre in length including all accessories complete. (A) Ground Floor
(B) First Floor
(C) Second Floor
(D) Third Floor
Providing and fixing 450 millimetre X 550 millimetre size superior type Belgium mirror with 16 milimetre diametre nickel plated towel rod etc. complete. (A) Ground Floor
(B) First Floor
(C) Second Floor
(D) Third Floor
Providing and fixing Poly Vinyl Chloride Rain water pipes of 160 millimetre outer diameter and having wall thickness of 2.2 to 2.7 millimetre confirming to Indian Standard 13592-1992 including proper rainwater receiving recess with Poly Vinyl Chloride plug, bend, necessary fittings, such as, offsets, shoes, inluding fixing the pipe on wall using approved wooden cleats projecting 25 millimetre to 40 millimetre from face of wall a fixing with clips of approved quality and number, filing the joint using rubber gasket with solvent cement and properly resting the shoe of pipes on CEment Concrete or masonry blocks, including necessary scaffolding and maintenance for 3 yrs for any leakages or dislocations of pipes. All the Poly Vinyl Chloride fittings and additional 2 piece socket clips shall be got approved from engineer in charge etc. complete. (The contractor shall give 3 yrs guarantee bond for payment)
Providing and fixing 15 centimeter x 10 centimeter salt glazed stoneware gully trap in cement concrete 1:4:8 outside the building including cast iron grating in the sink, connecting glazed stoneware pipe, brick masonry chamber with cast iron lid and cast iron grating for the gully trap.
Providing and constructing Brick Masonry Inspection Chamber 60 centimetre X 45 centimetre X 90 centimetre including 1:4:8 cement concrete foundation 1:2:4 cement concrete channels half round Glazed Stoneware pipe pipes, Brick Masonry, plastering from inside and with frame fixed in cement concrete etc. complete with Reinforced Cement Concrete Cover.
Providing and constructing Brick Masonry Inspection Chamber 90 centimetre X 45 centimetre X 90 centimetre including 1:4:8 cement concrete foundation 1:2:4 cement concrete channels half round Glazed Stoneware pipepipes, Brick Masonry, plastering from inside and with frame fixed in cement concrete with Reinforced Cement Concrete Cover.
Providing and fixing 40 millimetre dia Ball cock medium type with Poly Vinyl Chloride float including sockets and necessary fittings and tested as per municipal requirements etc. complete. (B) First Floor
(C) Second Floor
(D) Third Floor
Providing and fixing machine cut mirror polished 18 millimetre to 20 millimetre thick telephone black granite / Amba White / Cat bary brown / RBI red / Ocean Brown granite stone partition with rounding the edges etc. complete . Both side polish (A) Ground Floor
Providing and fixing H.D.P container Sintex or alike one piece moulded water tank made out of low density polythyler and built corrugation including of delivery up to destination hoisting and fixing of accessories such as inlet, outlet overflow of all tanks capacity above 1000 to 20,000 litres (A) Ground Floor
(B) First Floor
(C) Second Floor
(D) Third Floor
Providing soak pit of size 120 centimetre X 120 centimetre X 120 centimetre including excavating and filling with brick-bats.
Providing and fixing Chromium Plated sink cock with raised J" shaped swinging casted spout of approved make including necessary sockets/ union nut etc. complete." (B) First Floor
(C) Second Floor
(D) Third Floor
Providing and fixing Chromium Plated BIB cock with wall flange of approved make including necessary sockets/ union nut etc. complete as directed by Engineer in charge. (A) Ground Floor
(B) First Floor
(C) Second Floor
(D) Third Floor
Providing and fixing Shutter to wall Cupboard consisting of Teak Wood styles and Rails 25 millimetre thick and 75 millimetre wide with panel insert of 12 millimetre thick particle Board with one approved coloured Laminated Face on one side 1.5 millimetre thick, bonded with Phenol Formaldehyde Synthetic Resin including Lipping Beading. Iron oxidised fixtures and fastening and oil primer coat etc. complete. (Excluding cupboard frame). (B) First Floor
(C) Second Floor
(D) Third Floor
Providing and laying concrete pipes of Indian standard NP. class of 300 millimetre diameter in proper line, level and slope including necessary collars, excavation, laying, fixing with collars in cement mortar 1:1 and refilling the trench complete.
Providing and fixing reinforced cement concrete cover of size 60 centimetre x 45 centimetrewith frame over inspection chamber etc. complete.Medium duty (100 kilogram)
Providing and fixing 90 centimetre X 60 centimetre Granite plate engraving 10cm. height letter, figures including painting the lefters / figures with approved colour and shade complete.
Providing and fixing 45 centimetre wide mild steel ladder of 40mm x 6 mm mild steel flat stringers and steps of 18 millimetre diamtre mild steel bar for water tank including fixing it in (1:2:4) M-15 cement concrete block 60 centimetre X 30 centimetre X 30 centimetre and painting the ladder complete. (Anti Corossive Paint)
Providing and fixing in position Unplasticized Poly Vinol Chloride ultra violet stabilized 110 millimetre outer diameter cowl dome confirming to IS.-4985 including making joints with solvent cement etc. Complete (B) First Floor
(C) Second Floor
(D) Third Floor
Providing and fixing lightening conductor system comprising of erecting Air-Termination consisting of tubular copper rod of 25 millimeter dia. 1.2 millimeter thick with multiple points head 1.2 metre long ( Heavy Duty) welded or clamped to Galvanised Iron pipe pole B grade 50 millimeter diametre of requiired length with Mild Steel round bnase plate 25 centimetre diametre and 10 millimeter thick at bottom embeded in cement concrete 1:3:6 foundation of size 45 centimetre diametre x 45 centimetre Height and providing earthing with copper earth plate of size 60 x 60 x 0.3 centimetre with cadmium plated nut bolts to fix earthing strip burried in specially prepared earth pits 1.5 metre below ground level with 40 kilogram charcoal and salt with altemate layers of charcoal and salt and Galvanised Iron pipe 40 millimeter diametre 2 meter length burried in earth upto earthling plate remining portion above ground level for watering and refilling comcpete Note- Copper strip fropm lightening conductor is not considered in this item.
Providing and fixing copper strip 25 millimeter wide and 3 millimeter thick for lightening conductor including fixing with screws required scaffolding etc.complete Note- Lightening conductor and earthing pits is not considered in this item
Conveying materials obtained from road cutting including all lifts, laying in layers of 20cm to 30cm. breaking clods, dressing to the required lines, curves, grades and section, watering and compacting to not less than 97% of standard Proctor density for a lead of over 50m. to 300m. inclusive from the site of excavation to the site of deposition as directed.
Excavation for roadway in earth, soil of all sorts, sand, gravel or soft murum including dressing section to the required grade, camber and side slopes and conveying the excavated materials with all lifts upto a lead of 50 metre and spreading for embankment or stacking as directed.
Excavation for roadway in hard murum including dressing section to the required grade, camber and side slopes and conveying the excavated materials with all lifts upto a lead of 50metre and spreading for embankment or stacking as directed.
Excavation for roadway in soft rock, including dressing section to the required grade, camber and side slopes and conveying the excavated materials with all lifts upto a lead of 50metre and spreading or stacking as directed.
Providing and laying in situ cement concrete M -30 with tremix treatment for 200 millimetre thickness for Concrete Road is including laying plastic sheet for 125 micron thickness with groove cutting of 4 millimetre wide and 20 millimetre deep with necessary refilling with bitumen ( excluding reinforcement) with coarse and fine aggregate Vertical Shaft Impactor grade finely washed crushed sand) etc. complete
Providing, laying, spreading and compacting hand broken aggregates of specific sizes to water bound macadam specification including spreading in uniform thickness, hand packing to proper grade and camber, applying and brooming requisite type of screening/ Hard Murum Blindage as binding Materials to fill up the interstices of aggregate, watering and compacting with Power Roller to the required density. By Manual Means - Grading I (Using 60 millimetre metal)
Providing, laying, spreading and compacting hand broken aggregates of specific sizes to water bound macadam specification including spreading in uniform thickness, hand packing to proper grade and camber, applying and brooming requisite type of screening/ Hard murum Blindage as binding Materials to fill up the interstices of aggregate, watering and compacting with Power Roller to the required density. By Manual Means - Grading II (Using 40 millimetre metal)
Supplying hard murum/ kankar at the road site, including conveying and stacking complete.
Spreading hard murum/ soft murum/ gravel or kankar for side width complete
Compacting the hard murum side widths including laying in layers on each side with vibratory roller including artificial watering etc. complete.
Providing and constructing 75 millimetre thick Modified Penetration Macadam (MPM) road surface including all materials, preparing the existing road surface, spreading 40 millimetre stone metal layers 100 percent crusher broken metal with conical crusher plant heating and spraying the bitumen of specified grade @ 2 Kilogram per Square metre, spreading 12 millimetre size chips compacting with three wheel static roller having weight 8 to 10 Metric Tonne to achive the desired degree of compaction as per Technical Specification Clause 506 etc. complete. Including picking of existing Water Bound Macadam surface. (Viscosity Grade-30 bulk bitumen rates are considered to arrive at rates)
Providing and applying tack coat on the prepared surface heating by flames in Boiler and spraying bitumen with sprayer on Granular surface treated with primer @ 2.75 kilogram per /10 Square Meter with Viscosity Grade-30 bulk Bitumen
Open Graded Premix Surfacing- Providing and Laying Open Graded Carpet 20 millimetre thickness composed of 13.2 millimetre to 5.6 millimetre aggregates premixed with bituminous binder transported to site with Vessel Traffic Services , laid over a previously prepared surface, finished to the required grade, level, alignment, and rolling to achieve the desired compaction but excluding prime / tack and Seal coat. For Bitumen of specified grade--USING drum mix type hot mix plant with Supervisory Control and Data Acquisition, Paver and Vibratory roller (over BT Surface) (Viscosity Grade-30 bulk bitumen rates are considered to arrive at rates)
Providing bituminous Type A liquid seal coat on bituminous surface including supplying all materials and bitumen of Viscosity Grade-30 grade preparing existing road surface, heating and applying bitumen @ 0.98 Kilogram per Square Metre. by mechanical means, spreading chips and rolling, by static roller having weight 8 to 10 Metric TonneT. etc. complete.
Planting large flowering / Shady trees / Decorative (Height 2 Mtr.)- Digging pit with size 0.9 metre x 0.9 metre x 0.9 metre removing and conveying unwanted stuff to a required distance as directed Filling the pit with approval excavated material uplo a height of 0.30 metre . and remaining height of 0.60 metre . with fresh garden soil and manure in 3:1 proportion. Mining soil & manure thoroughly well, levelling, as directed, watering previous night, planting two to three year old.minimum 2.0 metre .height. healthy trees sapling as per specifications. Maintaining till well established by watering, weeding, stirring of soil sinking replacing of casualties etc.complete.
GARDEN SOIL :- Supplying on site garden soil well sieved 90 Percent to pass through lndian Standard sieve of 10 milimetre size free from stones rubbish like dried grass roots and other such materials. The soil should be fresh from quarry. The colour of the soil generally be red. The soil will be measured by measuring box. (Farma)
Preparing lawn(30 centimetres Depth) :- Excavating the ground to a required depth of 30 centimetres.removing and conveying unwanted stuff to a required distance as directed. Filling fresh garden soil/silt and manure in excavated area in 3:1 proportion to a height of 30 centimetres. Mixing garden soil and Manure thoroughly well, levelling, watering on previous night. Planting required variety of lawn grass as directed & maintaining till well established by watering, weeding, clipping or rolling etc.complete
Providing and fixing in position mild steel Tree Gaurd of 600 millimetre diametre and 1200 millimetre in height, placed 150millimetre above Ground Level. 4 Number of Angle 45 X 45 X 5 millimetre for Supports embeded in M20 cement concrete foundation Block. Providing & Fixing welded mesh of 11 gauge wires having mesh size 25 millimetre X 25 millimetre for gaurding trees. Top and Bottom Frame of Angle 45 X 45 X 5 millimetre supported with 35 X 5 Flat from inside face for fixing Welded Mesh. 35 X 5 millimetre Flat for supporting welded mesh for 1200millimetre height, including welding fixing of frame and all necessary fixtures etc. complete. As directed by Engineer in charge.
Maintenance of Garden in all respect for keeping gardening in good condition such as weeding, cleaning, watering, cutting, gap filling, manuaring cutting (Lawn, hedges, trees, flowers, etc.) and composting, preperation of bed plantation, trees, shrubs, ground covers, flower bed, lawn etc. with Toilet washing and cleaning for 1 Month.
Making 150 millimetre diametre Bore in all types of Strata with head core including survey for fixing location of bore transporting of machinery and platform, providing laying fixing casing of 150 millimetre diametre Unplacticised Poly Vinyl Chloride Pipe (CS as per IS:12815) having outer diametre 165 and minimum thickness of 5.70 to 6.50 millimetre diametre along with grouting, checking capacity by flushing test etc. complete. Survey for Fixing Location
Making Bore in all types of Strata
Providing and Laying and fixing casing of 150 millimetre diametre Ultra Poly Vinyl Chloride pipe to withstand continous internal hydraulic pressure of 6 kilogram per square centimetre (Cross Section as per IS:12818-1992) having outer diametre 165.40 millimetre and minimum thickness 5.70 to 6.50 millimetre along with grouting.
Checking Capacity by Flushing test
Supplying and erecting submersible pumpset of 2.25 KW/3 HP with 415 V, 50 c/s AC supply suitable for 150 milimetre diametre borewell 3HP (2 stage) suitable for 200 to 500 Litre Per Minute discharge at 21 to 11 metre head & (max. efficiency at 19 metre head & 300 litre per minute ) discharge & delivery Pipe of Size-50 milimetre diameter with a necessary H type clamps as per specification no. WPSMP
Supplying and erecting Centrifugal water pump (Monoblock), 415V, three phase 50 cycles A.C. supply of 1.5 KW/2 HP with discharge 2.2/4.1 Litres per second (LPS) for head of 8/26 m and 50 mm suction/ 40 mm delivery pipe on provided C.C. foundation as per specification no. WP-CGP
Supplying and erecting flat flexible 3 core 2.5 square milimetre PVC sheathed submersible type copper cable suitably clamped at fixed intervals with column pipe assembly complete.
Supplying and erecting D.O.L. Starter400V. 3 phase, 50 cycles with no volt coil and overload element with necessary materials and connected to supply upto 7.5 H.P.
Designing (aesthetically), and constructing Reninforced Cement Concrete elevated service reservoirs of following capacity with Reninforced Cement Concrete staging consisting of columns, internal and external bracings spaced vertically not more than 4.5 meters centre to centre including excavation in all types of strata, foundation concret, cement plaster with water proofing compound to the inside face of the container including refilling disposing of the surplus stuff within a lead of 50 meters, all labour and material charges including lowering, laying, erecting, hoisting and jointing of pipe assembly of inlet, outlet, washout, overflow and bypass arrangements as per departmental design, providing and fixing accessories such as Mild Steel adder, Cast Iron manhole frame and covers water level indicatiors, lightening conductor, Galvanised Iron pipe railing around walk way and top slab, providing spiral staire case from ground level to roof level, Mild Steel Grill gate of 2 Metres height with locking arrangement, Burnt Brick masonry chambers for all valves, ventilating shafts, providing and applying three coats of cement paint to the structure including roof slab and epoxy paint to internal surface & anti-termite treatment for underground parts of the structures and giving satisfactory water tightness test as per Indian Standard code, The job to include painting the name of the scheme and other details on the reservoir as per the directions of Engineer-in-charge.
Providing and supplying Indian Standard Institute standard Cast Iron double flanged pipes including all taxes (Central and local), railway freight, insurance, unloading from railway wagon, loading into truck transport to stores / site, unloading etc. complete as directed by Engneer-in-charge. 80 milimetre Diametre CIDF Pipe
Providing & Supplying Indian Standard Institute mark CIDF Specials for CIDF Pipe
Providing Indian Standard Indtitute mark Galvanised Iron pipe of following clss and diametre Including all and central taxes, etc..complete. MEDIUM 80 milimetre Diametre B Class Pipe
65 milimetre Diametre B Class Pipe
Providing and Supplying at site ofwork Galvanised Iron/ hdpe specials suitable for above saod pipes including cost of all taxes. frreight charges . octroioading . unloading . coneyance todepartmental storres etc. complete (Notes. 10% of cost of pipes Material)
Providing and supplying Indian Standard Institute mark CI D/F reflux valves (non-return valves ) of following diametre including all taxes (Central and Local), railway freight, inspection charges unloding from railway wagon, loading into truck, ransportation upto departmental stroes/ site, unloading, stacking etc. complete. Reflux valves as per Indian Standard 5312 Part I (1984) Without by pass arrangement - PN -1 80 milimetre NRV
Providing and Supplying Indian Standard Institute mark CIDF sluice valves and butterfly valves of following diameter including all central and local taxes,octroi, inspectiion charges railway freight unloading from railway wagons, loading into trucks and transportation to fepartmental storre stacking etc. complete (Sluice valve as per Indian Standard 780 & 2906 -1994 & Butter fly valves as per Indian Standard 13095 -1991) 80 milimetre Diametre Sluice valve
65 milimetre Diametre Sluice valve
Providing and supplying Air Valves as per IS14845 and MJP’s standard specifications double orifice type combined with screw down isolating valve, small orifice elastic ball resting on a gun metal orifice nipple, large orifice vulcanite ball seating on moulded seat ring, inlet face and drilled, including insurance, third party inspection charges, loading, unloading, transportation upto departmental stores, excluding GST levied by GOI & GOM 25 milimetre CI A.V. PN-1.6
Excavation for pipe trenches in earth soils of all types of sand gravel and soft murum and hard murum including removing the excavated material upto a distance of 50 meters and lift ass below stacking and spreading asbelow,stacking and strutting prreparing the bed for the foundation etc. complete. Lift 0 to 1.5 Metre
Excavation for foundation /pipe trenches in hard murum and boulders Water Bound Macadam Road including removingthe excavated material upto a distance of below. Stacking and spreading as below,stacking and spreading as directed mormal dewatering. Preparing the bed for foundation excluding back filling etc. complete
Excavation for foundation / pipe trenches in soft rock and old cement and lime masonry foundation asphalt road including removing the excavated material upto a distance of 50 Metre beyond area and lifts as below, stacking as directed by Engineer-incharges, normal dewatering, preparing the bed for foundation and excluding backfilling, etc. complete. Lift 0 to 1.5 Metre
Excavation for foundation / pipe trenches in hard rock and concrete road by chiselling, wedging, line drilling, by mechanical means or by all means other than blasting including trimming and levelling the bed, removing the excavated material upto a distance of 50 metres beyond the area and lifts as below, stacking as directed by Engineer-in-charge, normal dewatering,excluding backfilling, etc. complete by all means.
Lowering, laying and jointing Galvanised Iron pipes and specials of following class and diameter including conveyance from stores to site of works, all labour, etc. complete either underground or in vertical position, as directed 80 milimetre Diametre B Class Pipe
65 milimetre Diametre B Class Pipe
Lowering , laying asnd jointing in position following diameter C.I.D.F. sluice valves,reflux valves, including cost of all labour. Hydrasulic testing etc. complete. (Rate for all class of valves) 80 mm NRV
80 milimetre Diametre Sluice valve
65 milimetre Diametre Sluice valve
Providing and constructing Burnt Brick masonary valve chamber with 15 centimetre thick 1:3:6 pro Plain Cement Concrete Bending ,additional excavation Burnt Brick masonary in centimetre 1:5 centimetre thick precast Reinforced Cement Concrete Frame and cover etc. complete as directed For 90 X 60 centimetre internal size and depth upto 1.2 meter with precast Reinforced Cement Concrete slab cover 90 X 45 Centimetre
Providing and laying in situ 1:3:6 Plain Cement Concrete of trap /granite /gneiss metal for incasing pipe compacting curing and finishing etc. comp.
Refilling the trenches with available stuff with soft material first over pipe line and then hasrd material in 15 centimetre layer with all leads with all leads one lifits involved consolidation surcharging etc complete.
Providing and constructing two taps standpost as per type design wih excavation 15 centimetre thick Plain cement concrete 1:3:6 bedding 20 milimetre thick Plain cement concrete 1:2:4 concrete for platform of 1.75 Metre diametre with side curb and bucket rest, 80 milimetre dia, heavy duty Galvanised Iron pipe central post duly filled therein with Cement concrete 1:2:4, 5 Metre long, 20 milimetre diametre medium Galvanised Iron pipe from point of tapping to standpost additional 20 milimetre diametre Galvanised Iron pipe fixed ertically upto 15 milimetre diametre self closing water taps, one brass ferrule etc. complete together with all labour and material charges as per drawing and as directed by Engineer-in-charge when good foundation is available. Rate includes draining arrangemment by excavating open gutters.
Supplying and erecting PVC trunking (PVC casing-n-capping) of size 25 mm with accessories on wall/ceiling as per specification No: WG-MA/CON.
Supplying and erecting HMS PVC conduit FRLS grade 20 mm dia. with necessary accessories in wall/floor with chiselling appropriately as per specification No: WG-MA/CC.
Supplying and erecting mains with 2x2.5 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places. as per specification No: WG-MA/BW
Supplying and erecting mains with 1x2.5 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places as per specification No: WG-MA/BW
Supplying and erecting mains with 2x4 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places. as per specification No: WG-MA/BW
Supplying and erecting mains with 1x4 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places. as per specification No: WG-MA/BW
Supplying and erecting modular type switch 16 / 20 A with indicator, duly erected on provided plate and box with wiring connections complete.
Supplying and erecting modular type 3 pin 6A multi socket with safety shutter, duly erected on provided plate and box with wiring connections complete.
Supplying and erecting modular type blanking plate two module, duly erected on provided plate & box.
Supplying and erecting PVC Surface modular switch box with double mounting & front plate for 8 module complete duly connected.
Supplying and erecting modular type 3 pin 6 / 16A multi socket with safety shutter, duly erected on provided plate and box with wiring connections complete.
Supplying and erecting PVC Surface modular switch box with double mounting plate for 3 module duly erected.
Supplying and erecting modular type switch 6A / 10A duly erected on provided plate and box with wiring connections complete.
Supplying and erecting PVC Surface modular switch box with double mounting plate for 4 module duly erected.
Point wiring for light/bell/exhaust fan in PVC trunking (casing-capping) with 1.5 sq.mm (2+1E) FRLSH grade copper wire, modular type switch, earthing and required accessories as per specification No: WG-PW/SW
Point wiring for ceiling fan in PVC trunking (casing-capping) with 1.5 sq.mm (2+1E) FRLSH grade copper wire, modular type switch, earthing and required accessories as per specification No: WG-PW/SW
Wiring for plug on board with Switch socket surface/concealed type, copper wiring and earthing and with modular accessories as per specification No: WG-PW/CW.
Point wiring for independent plug in PVC trunking (casing-capping) with 1.5 sq.mm FRLSH grade copper wire, flush type switch, earthing and required accessories as per specification No: WG-PW/SW
Supplying & erecting inverter LED batten 20W tube light fitting with polycarbonate housing, heat sink, integrated HF electronic driver, Min. 2600 mAh Lithium ion Battery with charging time of 8-10 Hours and backup time of Min. 3 hrs. with minimum 25% of initial Watts having luminous efficacy of 100 lumen/watt, CRI>80, CCT of 6500K and THD<=20% having useful life of minimum 25000 hrs. with overheating protection with 2 years warranty.
Supplying and erecting bulk head LED fitting max. 10W with high transitivity diffuser with system lumens output of min. 1100 lumens, min. efficacy of 110 lumen/W, CRI>80, CCT upto 6500K, Beam Angle of 120 deg., THD<10%, p.f. >0.95, operating range of 140-260V, in built surge protection of 2.5 kV, Life class of 50,000 Hrs. at L70B50, including driver, IP66, IK09 rated on provided PVC Block / wooden board with 3 years warranty.
Supplying and erecting ding dong / electronic musical type call bell with heavy duty coil suitable to operate on 230V A.C. supply erected on polished double wooden block/sunmica block of suitable size.
Supplying and erecting exhaust fan medium duty 230 V A.C. 50 cycles 225 mm. 1400 RPM with condenser complete erected in position with necessary materials. Fan motor with moisture proof treatment and ‘E’ class insulation.
Supplying & erecting 22 SWG G.I sheet metal cawl sector shaped with 25 x 25 x 3 (mm) angle iron frame, metal mesh to avoid birds entry with necessary material, suitable for exhaust fan of 300 mm as per specification no FG-FAS/MSC
Supplying and erecting energy saving ceiling fan 230 V A.C. 50 cycles 1200 mm complete erected in position as per specification no. FG-FN/CF
Supplying and erecting modular type (two module) electronic step regulator for fan, duly erected on provided plate and box with wiring connections complete.
Supplying and erecting ‘B’ class G.I .pipe / M.S. pipe down rod duly painted for fan complete erected with PVC three core flexible cable 1 sq. mm copper PVC wire.
Supplying and erecting fan hook of 10 mm. M.S. round bar grouted in RCC slab with making the site as original.
Providing & erecting floor/wall mounting, MCCB panel board, with door, suitable for four pole incoming 250A, 8 ways Four pole outgoing, up to 100 A MCCBs on iron frame, as per specification no SW-SWR/MCCBPB. (Excluding MCCBs)
Providing & erecting incoming and outgoing cable alleys suitable for MCCB panel board with door, 250A incoming and 8 way outgoing or 400A incoming and 6 way outgoing made from CRCA sheet 1.6 mm thick duly powder coated and having vertical insulated partition for shielding between the shared face of cableway and DB.
Providing & erecting prewired meter module suitable for MCCB panel board with CTs and emfs VIF meter.
Supplying and erecting terminal spreaders suitable for 4 pole, up to 100A MCCB (Set of 8)
Supplying and erecting terminal spreaders suitable for 4 pole, above 100A up to 250A MCCB (Set of 8)
Supplying and erecting extended rotary handle for MCCB with adjustable telescopic rod suitable for up to 250A MCCB.
Providing & erecting 4 Pole MCCB 415V, 250A, rated short-circuit breaking capacity 36 kA (Ics=100% of Icu) adjustable thermal (overload) setting and adjustable magnetic setting with provided leads, provision for installation of shunt/UV/trip alarm contact and MCCB should have phase barriers both sides, with insulation withstand capacity 800V, no line-load bias in provided enclosure/panel as per specification no. SW-SWR/MCCB
Providing & erecting 4 Pole MCCB, 415 V, 100A, rated short-circuit breaking capacity 25 kA (Ics=100% of Icu), adjustable thermal (overload) setting and fixed magnetic setting with provided leads, provision for installation of shunt/UV/trip alarm contact. MCCB with phase barriers on both sides, insulation withstand capacity 800V, no line-load bias in provided enclosure/panel as per specification no. SW-SWR/MCCB
Supplying & erecting four pole ON LOAD change over switch, 415V, 160A, open execution having staggered termination, phase barrier, shroud termination and terminal cover along with auxiliary contacts and ready to upgrade with fuse protection kit, rotary handle, operational current category AC23A complying to IS/IEC 60947-3 Part-1/3.
Supplying & erecting triple pole and neutral distribution board (TPNDB), 3 pole/ 4 pole MCCB as incomer & outgoing SP MCB (12 poles) or TP MCB of 4 ways (12 poles), with door, 1.2mm thickness, surface/flush mounted, on iron/GI frame (vertical busbar type) as per specification no. SW-SWR/MCBDB1
Providing & erecting 4 Pole MCCB, 415 V, 100A, rated short-circuit breaking capacity 25 kA (Ics=100% of Icu), adjustable thermal (overload) setting and fixed magnetic setting with provided leads, provision for installation of shunt/UV/trip alarm contact. MCCB with phase barriers on both sides, insulation withstand capacity 800V, no line-load bias in provided enclosure/panel as per specification no. SW-SWR/MCCB
Supplying, erecting & terminating FRLSH XLPE armoured cable 4x6 sqmm copper conductor continuous 5.48 sqmm (12 SWG) G.I earth wire complete erected with glands and lugs on wall/trusses/pole or laid in trench/pipe as per specification no CBLT/CU.
Supplying, erecting & terminating FRLSH XLPE armoured cable 4x10 sqmm copper conductor continuous 5.48 sqmm (12 SWG) G.I earth wire complete erected with glands and lugs on wall/trusses/pole or laid in trench/pipe as per specification no CBLT/CU.
Supplying, erecting & terminating XL-HFFR insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 3½ core 25 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL
Supplying, erecting & terminating XL-HFFR insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 3½ core 35 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL.
Supplying, erecting & terminating XL-HFFR insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 3½ core 95 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL.
Supplying, erecting & terminating FRLS-XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 2 core 6 sq. mm. copper conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/CU.
Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 4 core 16 sq. mm. copper conductor complete erected with glands & lugs, on wall/ trusses/ pole or laid in provided trench/ pipe as per specification no. CB-LT/CU
Supplying, fixing and commissioning 2 pole RCBO 32/40A, with overcurrent, rated short-circuit breaking capacity (10 kA) and earth leakage protection, with 30/100/300 mA sensitivity and short circuit and earth leakage trip indication as per specification no SW-RCCB/RCBO.
Supplying and erecting single pole and neutral distribution board (SPNDB), with 2 ways for incoming and 10 ways (10 poles) for outgoing SP MCBs, with door, 1.2mm thickness surface / flush mounted, IP 43 Protection on iron / GI frame as per specification no. SW-SWR/MCBDB
Supplying, erecting & marking SPMCB 6A to 32A, C-series with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB .
Supplying, erecting & marking SPMCB 6A to 32A, B-series with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB .
Supplying, erecting & marking TPMCB 40A to 63A, with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB.
Providng earthing with galvanized iron earth plate size 60 x 60 x 0.6 cm complete with all materials, testing & recording the results as per specification no. EA-EP
Supplying and erecting GI strip of high purity required size used for earthing on wall and/or any other purpose with necessary GI clamps fixed on wall painted with bituminous paint with joints required. As per specification no EA-EP.25x5 ( 60M x1kg/M)= 60 Kg
Supplying and erecting PVC trunking (PVC casing-n-capping) of size 40 mm with accessories on wall/ceiling as per specification No: WG-MA/CON.
Supplying and erecting 25 mm dia. corrugated flexible polypropylene conduit
Supplying and erecting modular type telephone socket one gang with safety shutter, duly erected on provided plate and box with wiring connections complete.
Supplying & erecting 2 pair telephone copper cable 0.5 mm dia. with high density polyethylene insulation, polyester taped, Nylon Rip Cord & grey colour sheathed with FR PVC, conforming to ITD specification S/WS 113C laid in provided PVC casing capping/conduit as per specification No. WG-TW
Supplying & erecting 10 pair, 0.5 mm dia. jelly filled armoured telephone copper cable with poly-al laminate moisture barrier, polythene sheathed, G.S.Tape armoured polythene jacketed having laid in provided trench as per specification No. WG-TW
Supplying & erecting over voltage protection magazine suitable for 10 pair as per specification no. WG-TW
Supplying, erecting & commissioning 10 pair module for connection & disconnection of telephone cable as per specification no. WG-TW.
Supplying, installing, testing & commissioning digital (hybrid) type EPABX of 6 x 16 extension complete.
Supplying, erecting & commissioning MDF Box 50x50 pairs made from min. 1.5mm thick MS sheet as per specification no. WG-TW
Supplying, installing, testing & commissioning push button telephone instrument desk top/wall mount with caller ID & Speaker unit as per specification complete.( on each floor 7 telephone instrument is proposed as per mention in descriptive schedule so total for G+1 floor 14 nos of telephone instrument is proposed).
Supplying, installing, testing & commissioning IP telephone instrument as per specification complete.
Supplying and installing cat-6 armoured cable with ECCS tape suitable for networking as per specification No. WG-COC/NC
Supplying and fixing 1 m UTP patch cord of Cat 6 type in position as per specification No. WG-COC/PC .
Supplying, fixing, and configuring broadband ADSL router with all accessories, on provided rack as per specification No. WG-NWC/ADSL ( On each floor 1 ADSL router is proposed) so overall 2 nos ADSL router is proposed.
Supplying, installing and testing UTP connector (RJ-45) as per specification No. WG-NAS/UTPC.
Supplying and fixing 24 port patch panel with tool-less keystone jacks in provided U Rack complete as per specification no. WG-NAS/PP
Supplying and fixing 9U wall mount rack (Dimension-DxWxH – 500x600x500 mm) as per specification No. WG-NAS/RAK
Supplying, fixing, and configuring 24 ports, POE switch in provided rack as per specification No. WG-NWC/ENS
Supplying and fixing tool-less IO (Ethernet) flush/surface type in provided modular box as per specification no. WG-NAS/IO
Supplying, erecting, testing and commissioning self contained water cooler 230/250V 50Hz nominal cooling capacity of 150 litres per hour and storage capacity 150 litres with partially stainless steel body as per specification no. AP-WCR/WC
Supplying and erecting ultra violet water purifier with softener for safe drinking water consisting of UV germicidal tube of 8W capacity, choke made of copper wire, two indicator lamps, dual function cartridge with output of purified water 1 litre/min with activated carbon filter and softener operating on 230V, single phase A.C. supply with UV fail & filter change indication system.
Supplying & erecting CRCA sheet metal one way enclosures of 1.2mm thickness suitable for DP MCB /TP MCB/FP MCB/RCCB/RCBO complete erected on angle iron/GI frame.
Supplying and erecting storage type water heater 15 litres capacity having standing loss <0.419 kWh / 24 hour / 45°C, high impact resistance engineering plastic body with anti corrosive high grade steel inner tank heating element having hard water & corrosion protection, with minimum 3 safety protections (i.e. thermostat & thermal cut-out, multi function valve) with total pressure 8 bar withstanding capacity duly tested and marking sr. no. and date of erection complete. specification no. AP-WH/STWH.
Supplying, erecting, testing and commissioning of 3kVA capacity online pure sine wave with backup time of approx 2 hrs. PWM & IGBT based UPS with 0.8 to unity output pf, single phase input & 1 phase output complete with all protections as per specification no. AP-UPS .
Supplying and erecting 12V/100Ah SMF battery with battery terminal wire, duly charged with 24 months warranty complete.
Supplying, installing, testing & commissioning split type variable speed inverter technology with minimum 3 to 1 convertible mode for compressor, room air conditioning unit 1.3TR to 1.6TR capacity having ISEER minimum 5.00 suitable to operate on 250V, 50 Hz, A.C. supply having 1 no of air handling unit hi-wall/floor mounting type complete with refrigerant R32 having copper condenser, minimum 2.5PM filter, self diagnosis feature, stabilizer free operation & temperature display on indoor unit, noise level maximum 50dBA at position as per specification no. APAC/ WAC.
Supplying and erecting PVC insulated PVC round sheathed 4 sq.mm (56 no. x 0.30 mm dia.) 3 core flexible multi stranded copper Industrial cable for voltage grade up to 1.1 kV.
Supplying 16 amp. 3 pin plug Top bakelite type of 230 V. A.C. supply.
Supplying and erecting HMS PVC conduit FRLS grade 25 mm dia. with PVC accessories on wall /ceiling as per specification No: WG-MA/CON..
Supplying & erecting seamless outside & inside, smooth, dry and clean copper pipe with ROHS compliant suitable for refrigerant having 22SWG thickness and inner dia/size 12mm complete.
Supplying & erecting seamless outside & inside, smooth, dry and clean copper pipe with ROHS compliant suitable for refrigerant having 22SWG thickness and inner dia/size 16mm complete.
Supplying and erecting iron work, sheet metal work consisting of CRCA sheets, various sections of iron, plates, chequered plates, rods, bars, MS pipes, etc. for panel board or any other purpose with bending, cutting, drilling and welding complete erected at the position with necessary materials duly painted with one coat of red oxide and two coats of enamel paint to match the switchgears or as per directions by the authority.
Supplying and erecting elastomeric nitrile rubber / foam tube type sleeves for coating and insulating on provided PC / copper pipes having 9 mm thickness and inner diameter / sizes 12 mm for solar water heater/AC system.
Supplying and erecting elastomeric nitrile rubber / foam tube type sleeves for coating and insulating on provided PC / copper pipes having 9 mm thickness and inner diameter / sizes 16 mm for solar water heater/AC system.
Supplying, erecting, testing and commissioning of diesel generating set with alternator of 62.5 kVA output continuous rating, 3 Phase, 415 V, 50c/s 0.8 p. f. A.C supply, a totally enclosed air cooled / liquid cooled multi-cylinder diesel engine developing suitable BHP at 1500 rpm with 10% overload for 1 hour in 12 hours, along with standard accessories, self-excited, self-regulated, screen protected alternator with static excitation system running at 1500 RPM as per IS 4722-2001 with voltage regulation +/- 5 %, with performance class G2 and maximum fuel consumption 11.3 Ltr/hr @75% loading. Both the engine and alternator direct coupled on a common fabricated steel base frame and mounted on anti-vibrating pads with standard control panel comprising meters, switchgears, indicators connected with suitable wires/cables, the complete set enclosed in composite Acoustic enclosure as fully assembled integral unit made of 16 SWG CRCA Sheet, sound absorbing material to restrict sound level up to 75 dB at 1.0 m, provided with first filling of oil, diesel not less than 150 Ltr etc. on provided M20 Grade CC Foundation as per specification no. GEN-DG
Supplying, erecting, testing and commissioning of microprocessor based AMF panel suitable for diesel generating set of above 50 kVA up to 62.5 kVA capacity Three phase, 415 Volts, 50Hz A.C. with all standard features, safeties etc as per specification no. GEN-AMF.
Making cement concrete foundation in 1:3:6 cement concrete, (20 to 25) mm. stone metal duly plastered with necessary curing for complete. (pole muffing or any other purpose).SIZE -4*2.15*1.0 = 10 cu.mtr (plinth size 3.10 mtr x 2.25 mtr x 1 mtr= 6.96 cu mtr.
Excavating soft murum / soft soil road by chiselling for preparing pit for poles stay or earth plates or for laying cables, pipes & clearing the site by removing debris & making the site good complete. SIZE -4*2.15*1.0 = 10 cu.mtr (plinth size 4 mtr x 2.15 mtr x 0.3 mtr= 2.09 cu mtr.
Supplying, installing, testing and commissioning FR, XLPE armoured cable 4 core 1.5 sq.mm. copper conductor complete erected on wall/ ceiling complete as per specification no. CB-LT/CU
Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 4 core 70 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL.
Supplying and laying (including excavation of suitable width & depth up to 90 cm) 90 mm outside dia. double wall corrugated pipes (DWC) of HDPE for enclosing cable below ground/road surface, to required depth complete.
Providng earthing with galvanized iron earth plate size 60 x 60 x 0.6 cm complete with all materials, testing & recording the results as per specification no. EA-EP.
Providing earthing with copper earth plate size 30 x 30 x 0.315 cm complete with all materials, testing & recording the results as per specification no. EA-EP.
Supplying and erecting copper strip of high purity required size used for earthing on wall and/or any other purpose with necessary copper clamps fixed on wall painted with bituminous paint with joints required. As per specification no. EA-EP. (2 nos eart x 5 mtr long gi streep = 10 mtr x 1 kg/mtr =10 kg
Supplying and erecting GI strip of high purity required size used for earthing on wall and/or any other purpose with necessary GI clamps fixed on wall painted with bituminous paint with joints required. As per specification no EA-EP.(4 runs x 15mtr long each x 0.79Kg/mtr=47.4Kg .
Supplying and erecting PVC trunking (PVC casing-n-capping) of size 25 mm with accessories on wall/ceiling as per specification No: WG-MA/CON.
Supplying and erecting mains with 2x2.5 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places. as per specification No: WG-MA/BW
Supplying and erecting mains with 1x2.5 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places. as per specification No: WG-MA/BW
Supplying and erecting iron work, sheet metal work consisting of CRCA sheets, various sections of iron, plates, chequered plates, rods, bars, MS pipes, etc. for panel board or any other purpose with bending, cutting, drilling and welding complete erected at the position with necessary materials duly painted with one coat of red oxide and two coats of enamel paint to match the switchgears or as per directions by the authority. ( Angle =50x50x5 =12 mtr x 12.5 kg/mtr = 150kg + cutting bending 10 kg = 160 kg)
Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 3 core 25 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL.
Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 3½ core 120 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL
Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 3 core 4 sq. mm. copper conductor complete erected with glands & lugs, on wall/ trusses/ pole or laid in provided trench/ pipe as per specification no. CB-LT/CU.
Supplying and laying (including excavation of suitable width & depth up to 90 cm) 75 mm outside dia. double wall corrugated pipes (DWC) of HDPE for enclosing cable below ground/road surface, to required depth complete.
Providng earthing with galvanized iron earth plate size 60 x 60 x 0.6 cm complete with all materials, testing & recording the results as per specification no. EA-EP .
Supplying and erecting GI strip of high purity required size used for earthing on wall and/or any other purpose with necessary GI clamps fixed on wall painted with bituminous paint with joints required. As per specification no EA-EP.(9-2-3)(25x5) (1kg/mtr x25 mtr=25 kg)
Supplying & erecting Carbon Dioxide (CO2) fire extinguisher of 4.5 kg. capacity cartridge type conform to IS 2878 /15683 complete erected with necessary clamp made from 50 x 6 mm. M. S. flat with nut & bolts routed in wall complete.
Supplying, installation, testing and commissioning of main fire pump (MFP / EP) suitable for water discharge of 1800 to 2280 LPM at 80 to 60 m head driven by electric motor 415 volts, 3 phase 50 Hz, AC supply of 37kW or of suitable kW capacity for manual/automatic operation and consisting of following : (a) Horizontal type, single stage, centrifugal/split casing pump of cast iron body & bronze impeller with stainless steel shaft(SS410 grade), mechanical seal conforming to IS 1520. (b) Squirrel cage induction motor, TEFC, synchronous speed 3000 RPM, suitable for operation with IP 55 protection for enclosure, horizontal foot mounted type with Class-'F' insulation, conforming to IS-325. (c) M.S. fabricated Common base plate, coupling, coupling guard, foundation bolts etc. as required. (d) Erected on provided suitable size cement concrete foundation duly plastered with anti vibration pads with perfect aligning, proper levelling complete pump set with accessories duly painted with two coats of synthetic enamel paint of fire red colour over a coat of primer (ISC code 536 as per IS 2932 of 2003) complete, as per specification no. FF-MFP/SSC/EP
Supplying, installation, testing and commissioning of jockey fire pump (JP) suitable for water discharge of 180 to 240 LPM at 90 to 70 m head driven by electric motor 415 volts, 3 phase 50 Hz, AC supply of 9.3 kW or of suitable kW capacity for manual/automatic operation and consisting of following : (a) Horizontal/vertical type, multi stage, centrifugal casing pump of cast iron body & bronze impeller with stainless steel shaft(SS410 grade), mechanical seal conforming to IS 1520. (b) Squirrel cage induction motor, TEFC, synchronous speed 3000 RPM, suitable for operation with IP 55 protection for enclosure, horizontal foot mounted type with Class-'F' insulation, conforming to IS-325. (c) M.S. fabricated common base plate, coupling, coupling guard, foundation bolts etc. as required. (d) Erected on provided suitable size cement concrete foundation duly plastered with anti vibration pads with perfect aligning, proper levelling complete pump set with accessories duly painted with two coats of synthetic enamel paint of fire red colour over a coat of primer (ISC code 536 as per IS 2932 of 2003)complete, as per specification no. FF-MFP/JP.
Supplying and erecting G.I. pipe ‘C’ class ERW 25 mm dia with necessary fittings complete as per specification no. FF-PP
Supplying and erecting G.I. pipe ‘C’ class ERW 50 mm dia with necessary fittings complete as per specification no. FF-PP
Supplying and erecting G.I. pipe ‘C’ class ERW 65 mm dia with necessary fittings complete as per specification no. FF-PP
Supplying and erecting G.I. pipe ‘C’ class ERW 75/80 mm dia with necessary fittings complete as per specification no. FF-PP
Supplying and erecting G.I. pipe ‘C’ class ERW 100 mm dia with necessary fittings complete as per specification no. FF-PP
Supplying and erecting G.I. pipe ‘C’ class ERW 150 mm dia with necessary fittings complete as per specification no. FF-PP
Providing coating of bitumen paint & 4mm thick wrapping for underground 150 mm ring main of fire fighting system.
Supplying and erecting 100 mm dia Cast Iron end line strainer of Y-type flanged end pattern, PN16 pressure rating, SS screen, end connection with Flanged / Screwed / Socket Weld / Butt Weld End etc with standard OAR (open area Ratio) for positive suction complete as per specification no. FF-VL/ELS
Supplying and erecting 150 mm dia Cast Iron end line strainer of Y-type flanged end pattern, PN16 pressure rating, SS screen, end connection with Flanged / Screwed / Socket Weld / Butt Weld End etc with standard OAR (open area Ratio) for positive suction complete as per specification no. FF-VL/ELS
Supplying and erecting 75/80 mm dia. cast iron double flange butterfly valve of size complete with PN16 pressure rating, as per specification no. FF-VL/BFV .
Supplying and erecting 100 mm dia. cast iron double flange butterfly valve of size complete with PN16 pressure rating, as per specification no. FF-VL/BFV
Supplying and erecting 150 mm dia. cast iron double flange butterfly valve of size complete with PN16 pressure rating, as per specification no. FF-VL/BFV
Supplying and erecting 100 mm dia cast iron double flange ball type NRV complete with PN16 pressure rating, as per specification no. FF-VL/NRV
Supplying and erecting 150 mm dia cast iron double flange ball type NRV complete with PN16 pressure rating, as per specification no. FF-VL/NRV
Supplying and erecting 20 mm dia gun metal gate valve complete with PN16 pressure rating, as per specification no. FF-VL/GV
Supplying and erecting 25 mm dia gun metal gate valve complete with PN16 pressure rating, as per specification no. FF-VL/GV
Supplying and erecting 50 mm dia gun metal gate valve complete with PN16 pressure rating, as per specification no. FF-VL/GV
Supplying and erecting stainless steel single outlet hydrant valve fitted with necessary accessories complete as per specification no. FF-VL/HV
Supplying and installing wall mounting swinging hose reel drum fitted with 19 mm dia. 30m long high pressure polypropylene (Polyhose) along with necessary accessories complete as per specification no. FF-FFA/HV
Supplying and erecting 63mm dia, reinforced rubber lined (R.R.L.) hose pipe, 15m in length, fitted with necessary accessories complete as per specification no. FF-FFA/RRL
Supplying and erecting stainless steel branch pipe 63 mm dia fitted with 20 mm dia detachable hexagonal nozzle complete as per specifications no. FF-FFA/NZ .
Supplying and erecting 150 mm dia fire brigade header suitable for supplying water in fire tank complete as per specification no. FF-FA/FBC
Supplying and erecting fire brigade header ( Siamese connection )of 150 mm dia, for supplying water in fire tank complete as per specification no. FF-FA/FMC
Providing and fixing high-density polyethylene (HDPE) container one piece moulded triple layer water tank made out of high density polyethylene and built corrugated inclusive of delivery up to destination hoisting and fixing of accessories such as inlet, outlet overflow pipe inclusive of all tanks capacity up to 20000 litres.
Supplying and erecting 300 mm dia 1.5m in height air vessel / tank fabricated from min 5mm thick M.S. sheet complete as per specification no. FF-FFA/ACT .
Supplying and erecting 20/25mm dia gun metal air release cock, with necessary G.I. coupling to be fitted on top of air vessel or on wet riser complete as per specification no. FF-FFA/ARV.
Supplying and erecting 100 mm dia. pressure gauge , 0-300 PSI or 0-14 kg per cm square fitted with 12/15 mm dia. pad cock valve, erected with provided G.I. pipe, elbow etc. complete as per specification no. FF-FFA/PG.
Supplying and erecting 12/15 mm dia pressure switch with provided isolation valve, G.I. nipple, elbow, etc complete as per specification no. FF-FFA/PS
Supplying and erecting brass orifice plate having 6 mm. thickness, 140 mm outer dia with required diameter of inner hole at every single outlet hydrant valve as per specification no. FF-FFA/OP .
Supplying and erecting M.S./CRCA cabinet for housing Floor Hydrant valve, hose pipe, hose reel and branch pipe (size 1000 x 736 x 736 mm.) made from 16 SWG sheet and angle iron 25 x 25 x 4 mm. having front doors with viewing glass (8"x6") and locking arrangement with necessary fixing material such as rubber bidding etc. duly painted in post box red colour( Code 538 of IS 5)
Supplying and erecting M.S./CRCA cabinet for housing single hydrant valve of size ( 400 x 400 x 400)mm or hose pipe box of size ( 600 x 600 x 200)mm made from min. 1.5 mm thick CRCA sheet with angle iron work of min. of size (25 x 25 x 4) mm having front doors with viewing glass of size (200x150) mm and locking arrangement with necessary fixing material such as rubber bidding etc. duly painted in post box red colour( Code 538 of IS 5)
Supplying, erecting, testing and commissioning of quartzoid bulb sprinkler, 15 mm (½") dia. NBCM Body chrome finished, 68º C fixed temperature rating with deflector disc of conventional construction complete as per specification no. FF-SPR.
Supplying, erecting, testing and commissioning vane type water flow detector 100 mm dia. with 1) Visual switch activation 2) Rugged switch assembly 3) Heavy duty aluminium pipe saddles 4)Durable metal enclosure 5) Steel U bolts for secure mounting 6) Two SPDT ( Single pole double track ) synchronised switches 7) serviceable without draining pipes.
Making trench in Hard murum/Tar road having 0.75 m depth and minimum 0.3mtr width as per IS for laying provided cables up to voltage level 1.1Kv cable complete as per specification No. CW-EXN-CTR
Making cement concrete foundation in 1:2:4 cement concrete with foundation bolts and nuts complete. (cost of wooden box is included) (for pumps). (1.2x 1.2 x0.8)= 1.15 x 3 = 3.45 cum for overhead tank (1.8 x 1.8 x 0.9)=2.91cum total (3.45+2.91)= 6.36 Cu-M
Supplying, erecting testing and commissioning optical type smoke detector on suitable back box with necessary connections complete as per specification no. FF-FAS/SD
Supplying, erecting testing and commissioning manual call point (Pill box) with break glass, push button (resettable type) in metal enclosure complete as per specification no. FF-FAAS/MCP
Supplying, erecting, testing and commissioning hooters having high (100dB @ 1m) and low (94dB @ 1m) volume setting, group addressing facility allowing multiple sounders to be activated with CRCA enclosure complete as per specification no. FF-FAAS/HTR
Supplying, installing, testing and commissioning of 2 Zones Microprocessor based conventional fire alarm control panel (FACP) with standard accessories , 16x2 Character LCD Display, provision for zone wise contact and beep sound alarm, suitable to operate on 120-220 V AC, 0 - 49 Deg C, 93 ± 2 Percentage RH (non- condensing) at 32 ± 2 Deg C complete as per specification no. FF-FAAS/FACP =17839*10%+=4459.75 per zone for 8 Zone Panel =17588+4397*6=44597.50.*10%+44597.50=49057.25.
Supplying, installing, testing and commissioning 2 Zone, local signal control panel (LCP) with standard accessories complete as per specification no. FF-FAAS/LCP.(on each floor 4 nos LACP).
Supplying, installing, testing and commissioning FRLS, XLPE armoured cable 2 core 1.5 sq.mm. copper conductor complete erected on wall/ ceiling complete as per specification no. CB-LT/CU
Supplying, erecting, testing and commissioning 120 W amplifier suitable to operate on 230 Volts A.C. / 12 Volts D.C. supply complete as per specification no. FF-PA/AFR
Supplying, erecting, testing and commissioning 15 to 30 Watts sound column or ceiling mounted complete as per specification no. FF-PA/SOC
Supplying, erecting, testing and commissioning stand mounted/handheld type wired microphone having 2 mV/Pa sensitivity, impedance level limit 300 ohms and 50 - 16000 Hz suitable to operate in -10 deg C to +55 deg C with min. 7 metre shielded cable and 3 Pin Professional XLR Connector, stereo jack complete as per specification no. FF-PA/MIC
Supplying, erecting, testing and commissioning rust free microphone floor stand of chrome plating/powder coating or S.S. material , 500 mm to 1500 mm height and sturdy mechanism ensuring trouble free movement complete.
Supplying, erecting, testing and commissioning of 2 core shielded cable complete as per specification no. FF-PA/MCC
Supplying, erecting, testing and commissioning of 1.0 sq. mm speaker wire complete.
Supplying, installation, testing and commissioning of main fire pump (MFP/DP) suitable for water discharge of 1600 to 1800 LPM at 70 to 50 m head driven by 45 HP or suitable HP capacity diesel engine at required working speed suitable for manual/automatic operation and consisting of following : (a) Horizontal type, single stage, centrifugal casing pump of cast iron body & bronze impeller with stainless steel shaft (SS410 grade), mechanical seal conforming to IS 1520. (b) Water cooled with radiator, diesel engine conforming to relevant IS standard complete with auto starting mechanism, 12/24 volts DC electric starting equipment with battery of required AH capacity with necessary charger suitable to work on 230v, 50Hz AC supply, diesel tank of minimum 150ltr capacity with first filling of diesel up to 100% level with necessary piping with valves up to engine, exhaust pipe extended up to 10 m outside pump house duly insulated with 50 mm thick glass wool with 1.0 mm thick aluminium sheet cladding, residential silencer, instruments and protection as per standard specification, stop solenoid for auto stop in the event of fault with audio indications etc. as required. (c) M.S. fabricated common base plate, coupling, coupling guard, foundation bolts etc. as required. (d) Erected on provided suitable size cement concrete foundation duly plastered with anti vibration pads with perfect aligning, proper levelling complete pump set with engine assembly and accessories duly painted with two coats of synthetic enamel paint of fire red colour over a coat of primer (ISC code 536 as per IS 2932 of 2003) complete, as per specification no. FF-MFP/SSC/DP.
Supplying and erecting of fire Exit & Eire Exinguisher signlge Indicating the floor-numtber in words & syslem(Fire Exiinguisher & Accessories .
Supplying and erecting 25 mm dia. corrugated flexible polypropylene conduit.
Supplying and erecting PVC trunking (PVC casing-n-capping) of size 25 mm with accessories on wall/ceiling as per specification No: WG-MA/CON.
Supplying and erecting PVC trunking (PVC casing-n-capping) of size 32 mm with accessories on wall/ceiling as per specification No: WG-MA/CON.
Supplying and erecting mains with 2x1.5 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places as per specification No: WG-MA/BW .
Supplying and erecting mains with 1x1.5 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places as per specification No: WG-MA/BW .
Supplying and erecting mains with 2x2.5 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places. as per specification No: WG-MA/BW .
Supplying and erecting mains with 1x2.5 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places. as per specification No: WG-MA/BW.
Supplying and erecting mains with 2x4 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places. as per specification No: WG-MA/BW
Supplying and erecting mains with 1x4 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places. as per specification No: WG-MA/BW
Supplying and erecting modular type switch 6A / 10A duly erected on provided plate and box with wiring connections complete.
Supplying and erecting modular type switch 16A duly erected on provided plate and box with wiring connections complete.
Supplying and erecting modular type 3 pin 6A multi socket with safety shutter, duly erected on provided plate and box with wiring connections complete.
Supplying and erecting modular type 3 pin 6 / 16A multi socket with safety shutter, duly erected on provided plate and box with wiring connections complete.
Supplying and erecting modular type (two module) electronic step regulator for fan, duly erected on provided plate and box with wiring connections complete.
Supplying and erecting PVC Surface modular switch box with double mounting plate for 4 module duly erected.
Supplying and erecting PVC Surface modular switch box with double mounting & front plate for 8 module complete duly connected.
Wiring for plug on board with Switch socket surface/concealed type, copper wiring and earthing and with modular accessories as per specification No: WG-PW/CW (discriptive schedule attached).
Point wiring for light/bell/exhaust fan in PVC trunking (casing-capping) with 1.5 sq.mm (2+1E) FRLSH grade copper wire, modular type switch, earthing and required accessories as per specification No: WG-PW/SW
Point wiring for ceiling fan in PVC trunking (casing-capping) with 1.5 sq.mm (2+1E) FRLSH grade copper wire, modular type switch, earthing and required accessories as per specification No: WG-PW/SW
Supplying and erecting anodized aluminium corridor / passage light LED fitting (4 feet) Max. 22W with high transitivity diffuser with system lumens output of Min.2200 lumens , min. efficacy of 100 lumen/W, CRI>80, CCT upto 6000K, Beam Angle of 110 deg., Ripple<5%, THD<10%, p.f. >0.95, operating range of 200-270V, surge protection of 2 kV, Life class of 50,000 Hrs. at L70B50, including driver, with end caps on provided PVC Block / wooden board with 3 years warranty.
Supplying and erecting bulk head LED fitting max. 10W with high transitivity diffuser with system lumens output of min. 1100 lumens, min. efficacy of 110 lumen/W, CRI>80, CCT upto 6500K, Beam Angle of 120 deg., THD<10%, p.f. >0.95, operating range of 140-260V, in built surge protection of 2.5 kV, Life class of 50,000 Hrs. at L70B50, including driver, IP66, IK09 rated on provided PVC Block / wooden board with 3 years warranty.(discriptive schedule attached).
Supplying and erecting ding dong / electronic musical type call bell with heavy duty coil suitable to operate on 230V A.C. supply erected on polished double wooden block/sunmica block of suitable size.
Supplying and erecting integrated LED street light fitting 40 to 50W IP65 & IK08 class having single piece pressure die-cast aluminium housing, having system lumens output of Min. 4400 Lumens, min. efficacy of 110 lumen/W, CRI>70, CCT upto 6500K,THD<10%, p.f. >0.95, operating range of 140-270V, inbuilt surge protection of 10 kV, Life class of 50,000 Hrs. at L70B50, including driver complete with 3 Years warranty as per specification No FG-ODF/FLS2.
Supplying and erecting street light Wall bracket made from 40 mm. dia ‘ G.I. pipe 1.2 m. in total length complete as per specification no. FG-BKT/WB
Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 2 core 2.5 sq. mm. copper conductor complete erected with glands & lugs, on wall/ trusses/ pole or laid in provided trench/ pipe as per specification no. CB-LT/CU
Supplying & erecting FRP box of size 150mm x 125mm x 100 mm, 2.7 mm thick complete on pole/wall as per specification No. CB-SB
Supplying and erecting energy saving ceiling fan 230 V A.C. 50 cycles 1200 mm complete erected in position as per specification no. FG-FN/CF
Supplying and erecting fan hook of 10 mm. M.S. round bar grouted in RCC slab with making the site as original.
Supplying and erecting ‘B’ class G.I .pipe / M.S. pipe down rod duly painted for fan complete erected with PVC three core flexible cable 1 sq. mm copper PVC wire.
Supplying and erecting Ceiling rose / Batten holder / Slanting holder / hanging cord switch / hanging bell push / pendant holder bakelite base 6A. erected on filled polypropylene board or polished double wooden block/ PVC junction box.(passage light).
Supplying, erecting & marking SPMCB 6A to 32A, C-series with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB
Supplying, erecting & marking SPMCB 6A to 32A, B-series with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB
Supplying, erecting & marking DPMCB 6 A to 32 A, B-series with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB (street light and passage)
Supplying, erecting & marking DPMCB 40A to 63A, C-series with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB (for each room)
Supplying and erecting single pole and neutral distribution board (SPNDB), with 2 ways for incoming and 6 ways (6 poles) for outgoing SP MCBs, with door, 1.2mm thickness surface / flush mounted, IP 43 Protection on iron / GI frame as per specification no. SW-SWR/MCBDB
Supplying & erecting CRCA sheet metal one way enclosures of 1.2mm thickness suitable for DP MCB /TP MCB/FP MCB/RCCB/RCBO complete erected on angle iron/GI frame.
Supplying, fixing and commissioning 2 pole RCBO 32/40A, with overcurrent, rated short-circuit breaking capacity (10 kA) and earth leakage protection, with 30/100/300 mA sensitivity and short circuit and earth leakage trip indication as per specification no SW-RCCB/RCBO
Supplying and erecting marine (Waterproof) plywood 18/19 mm thick fixed to wall or on provided panel board with necessary materials such as screws, wall fasteners, supports, nut bolts etc. complete with compliance to IS 720:2010. For meter room 2x1.5=3 sqmtr
Supplying and erecting iron work, sheet metal work consisting of CRCA sheets, various sections of iron, plates, chequered plates, rods, bars, MS pipes, etc. for panel board or any other purpose with bending, cutting, drilling and welding complete erected at the position with necessary materials duly painted with one coat of red oxide and two coats of enamel paint to match the switchgears or as per directions by the authority.
Supplying and erecting bus bar chamber triple pole with neutral with four aluminium bars, 500V, 100A having 15mm (Width) X 3 mm (Thickness), with 99.9 % aluminium purity as per E91E Grade & Current Density 0.8 A per sq. mm. compliance to IS 5082 and Enclosure fabricated with 16 SWG CRCA sheet and epoxy paint, with suitable number of ways and with SMC/DMC Insulators and accessories of suitable rating complete as per specification no. CP-BB.
Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 2 core 6 sq. mm. copper conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/CU.
Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 4 core 50 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL.
Supplying and erecting exhaust fan medium duty 230 V A.C. 50 cycles 225 mm. 1400 RPM with condenser complete erected in position with necessary materials. Fan motor with moisture proof treatment and ‘E’ class insulation.
Supplying & erecting 22 SWG G.I sheet metal cawl sector shaped with 25 x 25 x 3 (mm) angle iron frame, metal mesh to avoid birds entry with necessary material, suitable for exhaust fan of 300 mm as per specification no FG-FAS/MSC
Supplying & erecting G.I. pipe ‘A’ class 40 mm dia. erected for enclosing XLPE armoured cable on wall/pole as per specification no. CB-CE.
Providng earthing with galvanized iron earth plate size 60 x 60 x 0.6 cm complete with all materials, testing & recording the results as per specification no. EA-EP
Supplying and erecting GI strip of high purity required size used for earthing on wall and/or any other purpose with necessary GI clamps fixed on wall painted with bituminous paint with joints required. As per specification no EA-EP. 25x5 (50 Mx 1kg/M)=50 Kg
Making trench in soft soil having 0.75 m depth and minimum 0.3 m width for laying provided cables up to voltage level of 1.1kV complete As per specification No. CW-EXN-CTR
Supplying and erecting 25 mm dia. corrugated flexible polypropylene conduit.
Supplying and erecting PVC trunking (PVC casing-n-capping) of size 25 mm with accessories on wall/ceiling as per specification No: WG-MA/CON.
Supplying and erecting PVC trunking (PVC casing-n-capping) of size 32 mm with accessories on wall/ceiling as per specification No: WG-MA/CON.
Supplying and erecting mains with 2x1.5 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places as per specification No: WG-MA/BW .
Supplying and erecting mains with 1x1.5 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places as per specification No: WG-MA/BW .
Supplying and erecting mains with 2x2.5 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places. as per specification No: WG-MA/BW .
Supplying and erecting mains with 1x2.5 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places. as per specification No: WG-MA/BW.
Supplying and erecting mains with 2x4 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places. as per specification No: WG-MA/BW
Supplying and erecting mains with 1x4 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places. as per specification No: WG-MA/BW
Supplying and erecting modular type switch 6A / 10A duly erected on provided plate and box with wiring connections complete.
Supplying and erecting modular type switch 16A duly erected on provided plate and box with wiring connections complete.
Supplying and erecting modular type 3 pin 6A multi socket with safety shutter, duly erected on provided plate and box with wiring connections complete.
Supplying and erecting modular type 3 pin 6 / 16A multi socket with safety shutter, duly erected on provided plate and box with wiring connections complete.
Supplying and erecting modular type (two module) electronic step regulator for fan, duly erected on provided plate and box with wiring connections complete.
Supplying and erecting PVC Surface modular switch box with double mounting plate for 4 module duly erected.
Supplying and erecting PVC Surface modular switch box with double mounting & front plate for 8 module complete duly connected.
Wiring for plug on board with Switch socket surface/concealed type, copper wiring and earthing and with modular accessories as per specification No: WG-PW/CW (discriptive schedule attached).
Point wiring for light/bell/exhaust fan in PVC trunking (casing-capping) with 1.5 sq.mm (2+1E) FRLSH grade copper wire, modular type switch, earthing and required accessories as per specification No: WG-PW/SW
Point wiring for ceiling fan in PVC trunking (casing-capping) with 1.5 sq.mm (2+1E) FRLSH grade copper wire, modular type switch, earthing and required accessories as per specification No: WG-PW/SW
Supplying and erecting anodized aluminium corridor / passage light LED fitting (4 feet) Max. 22W with high transitivity diffuser with system lumens output of Min.2200 lumens , min. efficacy of 100 lumen/W, CRI>80, CCT upto 6000K, Beam Angle of 110 deg., Ripple<5%, THD<10%, p.f. >0.95, operating range of 200-270V, surge protection of 2 kV, Life class of 50,000 Hrs. at L70B50, including driver, with end caps on provided PVC Block / wooden board with 3 years warranty.
Supplying and erecting bulk head LED fitting max. 10W with high transitivity diffuser with system lumens output of min. 1100 lumens, min. efficacy of 110 lumen/W, CRI>80, CCT upto 6500K, Beam Angle of 120 deg., THD<10%, p.f. >0.95, operating range of 140-260V, in built surge protection of 2.5 kV, Life class of 50,000 Hrs. at L70B50, including driver, IP66, IK09 rated on provided PVC Block / wooden board with 3 years warranty.(discriptive schedule attached).
Supplying and erecting ding dong / electronic musical type call bell with heavy duty coil suitable to operate on 230V A.C. supply erected on polished double wooden block/sunmica block of suitable size.
Supplying and erecting integrated LED street light fitting 40 to 50W IP65 & IK08 class having single piece pressure die-cast aluminium housing, having system lumens output of Min. 4400 Lumens, min. efficacy of 110 lumen/W, CRI>70, CCT upto 6500K,THD<10%, p.f. >0.95, operating range of 140-270V, inbuilt surge protection of 10 kV, Life class of 50,000 Hrs. at L70B50, including driver complete with 3 Years warranty as per specification No FG-ODF/FLS2.
Supplying and erecting street light Wall bracket made from 40 mm. dia ‘ G.I. pipe 1.2 m. in total length complete as per specification no. FG-BKT/WB
Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 2 core 2.5 sq. mm. copper conductor complete erected with glands & lugs, on wall/ trusses/ pole or laid in provided trench/ pipe as per specification no. CB-LT/CU
Supplying & erecting FRP box of size 150mm x 125mm x 100 mm, 2.7 mm thick complete on pole/wall as per specification No. CB-SB
Supplying and erecting energy saving ceiling fan 230 V A.C. 50 cycles 1200 mm complete erected in position as per specification no. FG-FN/CF
Supplying and erecting fan hook of 10 mm. M.S. round bar grouted in RCC slab with making the site as original.
Supplying and erecting ‘B’ class G.I .pipe / M.S. pipe down rod duly painted for fan complete erected with PVC three core flexible cable 1 sq. mm copper PVC wire.
Supplying and erecting Ceiling rose / Batten holder / Slanting holder / hanging cord switch / hanging bell push / pendant holder bakelite base 6A. erected on filled polypropylene board or polished double wooden block/ PVC junction box.(passage light).
Supplying, erecting & marking SPMCB 6A to 32A, C-series with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB
Supplying, erecting & marking SPMCB 6A to 32A, B-series with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB
Supplying, erecting & marking DPMCB 6 A to 32 A, B-series with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB (street light and passage)
Supplying, erecting & marking DPMCB 40A to 63A, C-series with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB (for each room)
Supplying and erecting single pole and neutral distribution board (SPNDB), with 2 ways for incoming and 6 ways (6 poles) for outgoing SP MCBs, with door, 1.2mm thickness surface / flush mounted, IP 43 Protection on iron / GI frame as per specification no. SW-SWR/MCBDB
Supplying & erecting CRCA sheet metal one way enclosures of 1.2mm thickness suitable for DP MCB /TP MCB/FP MCB/RCCB/RCBO complete erected on angle iron/GI frame.
Supplying, fixing and commissioning 2 pole RCBO 32/40A, with overcurrent, rated short-circuit breaking capacity (10 kA) and earth leakage protection, with 30/100/300 mA sensitivity and short circuit and earth leakage trip indication as per specification no SW-RCCB/RCBO
Supplying and erecting marine (Waterproof) plywood 18/19 mm thick fixed to wall or on provided panel board with necessary materials such as screws, wall fasteners, supports, nut bolts etc. complete with compliance to IS 720:2010. For meter room 2x1.5=3 sqmtr
Supplying and erecting iron work, sheet metal work consisting of CRCA sheets, various sections of iron, plates, chequered plates, rods, bars, MS pipes, etc. for panel board or any other purpose with bending, cutting, drilling and welding complete erected at the position with necessary materials duly painted with one coat of red oxide and two coats of enamel paint to match the switchgears or as per directions by the authority.
Supplying and erecting bus bar chamber triple pole with neutral with four aluminium bars, 500V, 100A having 15mm (Width) X 3 mm (Thickness), with 99.9 % aluminium purity as per E91E Grade & Current Density 0.8 A per sq. mm. compliance to IS 5082 and Enclosure fabricated with 16 SWG CRCA sheet and epoxy paint, with suitable number of ways and with SMC/DMC Insulators and accessories of suitable rating complete as per specification no. CP-BB.
Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 2 core 6 sq. mm. copper conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/CU.
Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 4 core 50 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL.
Supplying and erecting exhaust fan medium duty 230 V A.C. 50 cycles 225 mm. 1400 RPM with condenser complete erected in position with necessary materials. Fan motor with moisture proof treatment and ‘E’ class insulation.
Supplying & erecting 22 SWG G.I sheet metal cawl sector shaped with 25 x 25 x 3 (mm) angle iron frame, metal mesh to avoid birds entry with necessary material, suitable for exhaust fan of 300 mm as per specification no FG-FAS/MSC
Supplying & erecting G.I. pipe ‘A’ class 40 mm dia. erected for enclosing XLPE armoured cable on wall/pole as per specification no. CB-CE.
Providng earthing with galvanized iron earth plate size 60 x 60 x 0.6 cm complete with all materials, testing & recording the results as per specification no. EA-EP
Supplying and erecting GI strip of high purity required size used for earthing on wall and/or any other purpose with necessary GI clamps fixed on wall painted with bituminous paint with joints required. As per specification no EA-EP. 25x5 (50 Mx 1kg/M)=50 Kg
Making trench in soft soil having 0.75 m depth and minimum 0.3 m width for laying provided cables up to voltage level of 1.1kV complete As per specification No. CW-EXN-CTR
Supplying and erecting 25 mm dia. corrugated flexible polypropylene conduit
Supplying and erecting PVC trunking (PVC casing-n-capping) of size 25 mm with accessories on wall/ceiling as per specification No: WG-MA/CON.
Supplying and erecting PVC trunking (PVC casing-n-capping) of size 32 mm with accessories on wall/ceiling as per specification No: WG-MA/CON.
Supplying and erecting mains with 2x1.5 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places as per specification No: WG-MA/BW
Supplying and erecting mains with 1x1.5 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places as per specification No: WG-MA/BW
Supplying and erecting mains with 2x2.5 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places. as per specification No: WG-MA/BW
Supplying and erecting mains with 1x2.5 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places. as per specification No: WG-MA/BW
Supplying and erecting mains with 2x4 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places. as per specification No: WG-MA/BW
Supplying and erecting mains with 1x4 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places. as per specification No: WG-MA/BW
Supplying and erecting modular type switch 6A / 10A duly erected on provided plate and box with wiring connections complete.
Supplying and erecting modular type switch 16A duly erected on provided plate and box with wiring connections complete.
Supplying and erecting modular type 3 pin 6A multi socket with safety shutter, duly erected on provided plate and box with wiring connections complete.
Supplying and erecting modular type 3 pin 6 / 16A multi socket with safety shutter, duly erected on provided plate and box with wiring connections complete.
Supplying and erecting modular type (two module) electronic step regulator for fan, duly erected on provided plate and box with wiring connections complete.
Supplying and erecting PVC Surface modular switch box with double mounting plate for 4 module duly erected.
Supplying and erecting PVC Surface modular switch box with double mounting & front plate for 8 module complete duly connected.
Wiring for plug on board with Switch socket surface/concealed type, copper wiring and earthing and with modular accessories as per specification No: WG-PW/CW (discriptive schedule attached).
Point wiring for light/bell/exhaust fan in PVC trunking (casing-capping) with 1.5 sq.mm (2+1E) FRLSH grade copper wire, modular type switch, earthing and required accessories as per specification No: WG-PW/SW
Point wiring for ceiling fan in PVC trunking (casing-capping) with 1.5 sq.mm (2+1E) FRLSH grade copper wire, modular type switch, earthing and required accessories as per specification No: WG-PW/SW
Supplying and erecting anodized aluminium corridor / passage light LED fitting (4 feet) Max. 22W with high transitivity diffuser with system lumens output of Min.2200 lumens , min. efficacy of 100 lumen/W, CRI>80, CCT upto 6000K, Beam Angle of 110 deg., Ripple<5%, THD<10%, p.f. >0.95, operating range of 200-270V, surge protection of 2 kV, Life class of 50,000 Hrs. at L70B50, including driver, with end caps on provided PVC Block / wooden board with 3 years warranty.
Supplying and erecting bulk head LED fitting max. 10W with high transitivity diffuser with system lumens output of min. 1100 lumens, min. efficacy of 110 lumen/W, CRI>80, CCT upto 6500K, Beam Angle of 120 deg., THD<10%, p.f. >0.95, operating range of 140-260V, in built surge protection of 2.5 kV, Life class of 50,000 Hrs. at L70B50, including driver, IP66, IK09 rated on provided PVC Block / wooden board with 3 years warranty.(descriptive schedule attached).
Supplying and erecting ding dong / electronic musical type call bell with heavy duty coil suitable to operate on 230V A.C. supply erected on polished double wooden block/sunmica block of suitable size.
Supplying and erecting integrated LED street light fitting 40 to 50W IP65 & IK08 class having single piece pressure die-cast aluminium housing, having system lumens output of Min. 4400 Lumens, min. efficacy of 110 lumen/W, CRI>70, CCT upto 6500K,THD<10%, p.f. >0.95, operating range of 140-270V, inbuilt surge protection of 10 kV, Life class of 50,000 Hrs. at L70B50, including driver complete with 3 Years warranty as per specification No FG-ODF/FLS2.
Supplying & erecting FRP box of size 150mm x 125mm x 100 mm, 2.7 mm thick complete on pole/wall as per specification No. CB-SB
Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 2 core 2.5 sq. mm. copper conductor complete erected with glands & lugs, on wall/ trusses/ pole or laid in provided trench/ pipe as per specification no. CB-LT/CU
Supplying and erecting street light Wall bracket made from 40 mm. dia ‘ G.I. pipe 1.2 m. in total length complete as per specification no. FG-BKT/WB
Supplying and erecting energy saving ceiling fan 230 V A.C. 50 cycles 1200 mm complete erected in position as per specification no. FG-FN/CF
Supplying and erecting fan hook of 10 mm. M.S. round bar grouted in RCC slab with making the site as original.
Supplying and erecting ‘B’ class G.I .pipe / M.S. pipe down rod duly painted for fan complete erected with PVC three core flexible cable 1 sq. mm copper PVC wire.
Supplying and erecting Ceiling rose / Batten holder / Slanting holder / hanging cord switch / hanging bell push / pendant holder bakelite base 6A. erected on filled polypropylene board or polished double wooden block/ PVC junction box.(passage light).
Supplying, erecting & marking SPMCB 6A to 32A, C-series with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB
Supplying, erecting & marking SPMCB 6A to 32A, B-series with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB
Supplying, erecting & marking DPMCB 40A to 63A, C-series with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB
Supplying, erecting & marking DPMCB 6 A to 32 A, B-series with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB (street light and passage)
Supplying and erecting single pole and neutral distribution board (SPNDB), with 2 ways for incoming and 10 ways (10 poles) for outgoing SP MCBs, with door, 1.2mm thickness surface / flush mounted, IP 43 Protection on iron / GI frame as per specification no. SW-SWR/MCBDB
Supplying & erecting CRCA sheet metal one way enclosures of 1.2mm thickness suitable for DP MCB /TP MCB/FP MCB/RCCB/RCBO complete erected on angle iron/GI frame.
Supplying, fixing and commissioning 2 pole RCBO 63A, with overcurrent, rated short-circuit breaking capacity (10 kA) and earth leakage protection, with 30/100/300 mA sensitivity and short circuit and earth leakage trip indication as per specification no SW-RCCB/RCBO
Supplying and erecting marine (Waterproof) plywood 18/19 mm thick fixed to wall or on provided panel board with necessary materials such as screws, wall fasteners, supports, nut bolts etc. complete with compliance to IS 720:2010. For meter room 1x1.5=3 sqmtr
Supplying and erecting iron work, sheet metal work consisting of CRCA sheets, various sections of iron, plates, chequered plates, rods, bars, MS pipes, etc. for panel board or any other purpose with bending, cutting, drilling and welding complete erected at the position with necessary materials duly painted with one coat of red oxide and two coats of enamel paint to match the switchgears or as per directions by the authority.
Supplying and erecting bus bar chamber triple pole with neutral with four aluminium bars, 500V, 100A having 15mm (Width) X 3 mm (Thickness), with 99.9 % aluminium purity as per E91E Grade & Current Density 0.8 A per sq. mm. compliance to IS 5082 and Enclosure fabricated with 16 SWG CRCA sheet and epoxy paint, with suitable number of ways and with SMC/DMC Insulators and accessories of suitable rating complete as per specification no. CP-BB
Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 2 core 10 sq. mm. copper conductor complete erected with glands & lugs, on wall/ trusses/ pole or laid in provided trench/ pipe as per specification no. CB-LT/CU
Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 4 core 25 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL
Supplying and erecting exhaust fan medium duty 230 V A.C. 50 cycles 225 mm. 1400 RPM with condenser complete erected in position with necessary materials. Fan motor with moisture proof treatment and ‘E’ class insulation.
Supplying & erecting 22 SWG G.I sheet metal cawl sector shaped with 25 x 25 x 3 (mm) angle iron frame, metal mesh to avoid birds entry with necessary material, suitable for exhaust fan of 300 mm as per specification no FG-FAS/MSC
Supplying & erecting G.I. pipe ‘A’ class 40 mm dia. erected for enclosing XLPE armoured cable on wall/pole as per specification no. CB-CE
Providng earthing with galvanized iron earth plate size 60 x 60 x 0.6 cm complete with all materials, testing & recording the results as per specification no. EA-EP
Supplying and erecting GI strip of high purity required size used for earthing on wall and/or any other purpose with necessary GI clamps fixed on wall painted with bituminous paint with joints required. As per specification no EA-EP.25x5 (20 Mx 1kg/M)=20 Kg.
Making trench in soft soil having 0.75 m depth and minimum 0.3 m width for laying provided cables up to voltage level of 1.1kV complete As per specification No. CW-EXN-CTR.
Harsh Constructions Pvt Ltd
M/s Kranti Construction
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Download all tender documents and submit your bid