| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹7.2 LAccepted-AOC | L1 | Accepted-AOC being lowest | |
| 2 | L2₹8.3 L+₹1.0 L (14.0%)Rejected-Finance 15 15 KHERIYA BHAN PURANI CHAWANI GWALIOR GWALIOR GWALIOR MADHYA PRADESH 474010 | GWALIOR | MADHYA PRADESH | 474010 | L2 | Rejected-Finance Highest amount quoted | |
| 3 | L3₹9.2 L+₹2.0 L (27.1%)Rejected-Finance | L3 | Rejected-Finance Highest amount quoted |
Tender Value
₹9.9 L
EMD Value
₹19,800
Closing Date
12 Jun 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
AGE I UDAIPUR
ASST. GARRISON ENGINEER (I) EKLINGGARH CANTT, UDAIPUR (RAJ.) - 313001
REPAIRS AND MAINTENANCE TO HT OVERHEAD DISTRIBUTION SYSTEM AND CONNECTED WORKS IN ARMY AREA AT UDAIPUR MIL STN
2021_MES_444523_1
8652/E8/AGE I UDAIPUR
Open Tender
Civil Works
Item Rate
180 days
ARMY AREA UDAIPUR
as per tender documents
5 documents required · 5 mandatory
₹500
AGE I UDAIPUR
₹19,800
Yes
27 Aug 2022
20 May 2021
14 Jun 2021
20 May 2021
12 Jun 2021
21 May 2021
60 days
Amount
Takingdown/Dismantling of old ACSR or AAC conductors
Excavation in trenches n. exc. 1.5 mtr deep and n. exc. 1.5 mtr wide and getting out complete in hard/soft soil.
Returning & filling in layers n. exc. 25cm each including watering and well ramming after filling complete all as directed.
Removal of excavated surplus material to a distance n. exc. 50 mtr away in layer n. exc. 25cm from the starting point all as direcet by Engr-in-Charge.
Material & Labour Sand filling under floors or in foundations including watering and consolidation, spreading under stone/bricks aggrgate alround the LT panels/Feeder Pillars,cable laying etc.
Material and labour for stone slab ( patti) roughly hammer dressed stone 25 to 35 mm thick 25 to 40 cm wide and not less than 60 cm long laid dry and abutting each other with gap between adjacem,ent salb not exceeding 10 mm over underground cables for protection.
Material & Labour for supply and fixing laying cable in trenches,incl jointing with proper lugs, cable glan , HT under ground XPLE insulated, PVC sheathed 11000 V armoured heavy duty aluminium conductor including testing, jointing with kits at site at ends of cable and incl straight through as required, commissioning of size 95 Sq mm 3 core
Taking out old U/S and Supply & Fixing XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 10 sq. mm 4 core cable
Taking out old U/S and Supply & Fixing XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 6 sq. mm 2 core cable
Taking down old Unsv Go's and Supply & install 11 KV air break gang operated triple pole out door type gang operated air break switch mechanically operated, mounted on insulator and steel frame with operating mechanism worked from ground level with 09 Nos insulators outdoor type triple pole suitable for horizontal/vertical installation provided with locking arrangement consisting of MS channel HT post type insulator high pressure heavy lined copper alloy contact assembly suitable for 200 Amps, including air break switch suitable for 11 KV, 200 Amps mounted on 06 Insulators with drop out fuse unit ,operating rod 20m dia GI medium grade pipe complete all as specified and directed.
Material & Labour for renewal of earthing complete with galvanised steel earth plate electrode 60cm X 60cm X 6mm thick, burried directly in ground (earth pit not less than 2.25 mtr deep below normal ground level) with top edge of plate not less than 1.5 mtr below normal ground level connected to galvanized strip 32 X 6mm by means of bolts, nuts, check nuts and washers of galvanized iron or steel all as shown in electrical plate No 3 of SSR Part-I connected to OH conductor on pole/ Panel/ main switch board etc all as specified or indicated and testing on completion including provision galvanized strip protected by 40 mm bore, light grade pipe and watering pipe shall be 20 mm bore medium grade GI pipe including excavation & earth work, PCC pit with RCC cover, charcoal, salt, funnel, GI strip and protection pipe upto 7.5 mtr complete all as specified and directed.
Material & Labour for renewal of earthing complete with galvanised steel earth plate electrode 60cm X 60cm X 6mm thick, burried directly in ground (earth pit not less than 2.25 mtr deep below normal ground level) with top edge of plate not less than 1.5 mtr below normal ground level connected to galvanized earth lead wire 4.00 mm dia by means of bolts, nuts, check nuts and washers of galvanized iron or stee all as shown in electrcal plate No 3 of SSR Part-I connected to continious earth wire or main switch board/ panel etc all as specified or indicated and testing on completion including provision of earth wire protection by 15 mm dia,light grade GI pipe and watering pipe shall be 20 mm bore medium grade GI pipe including excavation & earth work, PCC pit with RCC cover, charcoal, salt, funnel, GI wire and protection pipe upto 7.5 mtr complete all as specified and directed.
Supply and install, testing and commissioning of Bus bar chamber of size 60 cm x 60cm x 40 cm outdoor type suitable for LT 415 volts 3 phase 4 wire system factory made cubical complete materialised dust and vermin proof (protection class IP 54), hinged type door both side opening with locking arrangement duly painted with two coats of synthetic enamel paint with powder coated finish over a coat of zinc chrome primer complete all including earth work ,excavation, PCC all as specified and directed by Engineer-In-Charge. the panel board shall be comprising of aluminum bus bar cap 200 Amps-04
Taking down old Unsv bus bars, and Supply and install, testing and commissioning of Bus bar chamber of size 60 cm x 60cm x 40 cm outdoor type suitable for LT 415 volts 3 phase 4 wire system factory made cubical complete materialised dust and vermin proof (protection class IP 54), made out of 3.15mm thick MS sheet (CRCA) including factory made hinged type door both side opening with locking arrangement duly painted with two coats of synthetic enamel paint with powder coated finish over a coat of zinc chrome primer complete all as specified and directed by Engineer-In-Charge. the panel board shall be comprising of the following accessories
(a) Copper bus bar cap 250 Amp-04
(d) RYB neon indicating lamp set of three- 01
Notes: (i) Rates are deemed to be inclusive of PCC platform of suitable size and 45cm height and 4 Nos legs of 50mmx50mmx6mm and 60 cm in height for fixing the panel (iii) Danger notice plate (02 Nos) LT size 20cmx 15cm shall be fixed on the panel (iv) Contractor provided power coated finish paint on panel.
Straightning of Over head conductor by strecthing between two HT poles of three spans as a whole and tightnening the conductors including providing of GI wire 4mm thick where ever is required.
Material & Labour for Cable route marker made out of GI non corrosion of size 150mm x 150mm x 5mm of plate and suitable height at least 2 feet from ground after grouting into the ground including writing the HT/LT Cable by engraqvinging/ painting complete fixed in PCC including excavation and RF and removing complete all as directed by Engr in Charge
Taking down old Unsv and supply and fixing Cable jointing kit for 11 kv (Eartherd ) grade cable for outdoor termination heat shrink type joint complete with jointing material and accssories suitable for 3 core XLPE armoured aluminium conductor cable of size 95 sq mm
Taking down old Unsv and supply and fixing Cable jointing kit for 11 kv (Eartherd ) grade cable joint, heat shrink type straight through joint complete with jointing material and accssories suitable for 3 core XLPE armoured aluminium conductor cable of size 95 sq mm
Taking down old Unsv and supply and fixing Cable jointing kit for 11 KV (Earthed) grade cable for indoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 95 sqmm
Material & Labour for Zebra painting with two coats of Ist quality synthetic enamel paint on HT/LT concrete poles up to 1.5 metre height from pedastal in 30 cm height in black & white paints including two coat of cement base paint on Pedastal of Pole and Painting the Cross arms with one coat of Synthetic/Aluminium enamel paint incl preparation of steel surfaces and including writing the pole Nos of 50mm height letters / figures with acrylic PVC strip "MES/LT ___" (pole number) all as directed
Taking down old unsv & Supply & fixing GI 80mm light grade protection pipe all as specified and directed
Taking down old unsv & Supply & fixing GI 40mm light grade protection pipe all as specified and directed
Taking down old unsv & Supply & fixing GI 25mm light grade protection pipe all as specified and directed
Supply & Fixing SMC junction box with bus bar with MCB of cap 20Amps 230 volts Make : Syntex or equivalent and make of MCB Havells/Legrand/Standard/ C&S all as directed by Engr- in- charge
AUTOMATION AND SWITCHGEAR PANELS
M/s SUNIL ENTERPRISES
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .