Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹6.6 CrAccepted-AOC | ₹6.6 Cr Quoted ₹7.9 Cr | L1 | Accepted-AOC L1 |
| 2 | L2₹8.7 Cr+₹80.2 L (10.2%)Rejected-AOC MAIN HUDA MARKET PLOT NO 62 HOUSE NO 62 GROUND FLOOR MAIN HUDA MARKET SECTOR 10A 122001 | GURUGRAM | HARYANA | 122001 | ₹8.7 Cr+₹80.2 L (10.2%) | L2 | Rejected-AOC L2 |
| 3 | L3₹9.0 Cr+₹1.1 Cr (13.8%)Rejected-AOC 14 CHAHAR CONSTRUCTION CO ADARSH NAGAR NEAR ROHILLA COMMUNICAION 124103 | JHAJJAR | HARYANA | 124103 | ₹9.0 Cr+₹1.1 Cr (13.8%) | L3 | Rejected-AOC L3 |
| 4 | L4₹9.5 Cr+₹1.6 Cr (20.5%)Rejected-AOC | ₹9.5 Cr+₹1.6 Cr (20.5%) | L4 | Rejected-AOC L4 |
| 5 | L5₹9.6 Cr+₹1.7 Cr (21.5%)Rejected-AOC VPO BERLA TEHSIL AND DISTT CHARKHI DADRI HARYANA | CHARKI DADRI | HARYANA | 127022 | ₹9.6 Cr+₹1.7 Cr (21.5%) | L5 | Rejected-AOC L5 |
Tender Value
Refer Docs
EMD Value
₹18.3 L
Closing Date
6 Sept 2022, 5:00 pmClosed
ANKIT BHARDWAJ
HSIIDC Office Complex, Sector-69 IMT Faridabad
Operation and Maintenance of Master Water Supply Scheme of Faridabad for Ranney Well Line No.4,5,6and7 including Ranney Wells, MBS, IBS and Pipe line/ Rising main (Ranney Well to MBS, MBS to IBS, IBS to SBS, tubewell and including Electric Feeder mai
2022_HRY_233618_1
2022D48685CF 3D50 44F9 8CFC 7F0375F9DD0E1851002
Open Tender
Civil Works
Works
730 days
Faridabad (MC)
2 documents required · 2 mandatory
₹1,180
₹18.3 L
Yes
27 Dec 2022
8 Aug 2022
7 Sept 2022
8 Aug 2022
6 Sept 2022
8 Aug 2022
Amount
[11.5.4]12 mm cement plaster of mix : 4. 1:6 (1 cement: 6 fine sand)
[17.24]Wet Mix Macadam Providing, laying, spreading and compacting graded stone aggregate to wet mix macadam specification including premixing the Material with water at OMC in mechanical mix plant carriage of mixed Material by tipper to site, laying in uniform layers with paver in sub- base / base course on well prepared surface and compacting with vibratory roller to achieve the desired density as per technical clause 406 of MORT&H specifications
[17.66.1]Rectangular Concrete Block Pavement 1. Providing and laying of cement concrete blocks of size 0.450 m x 0.300 m x 0.15 m of cement concrete (C.C) M30 grade and spreading 25 mm thick sand underneath filling joints with sand on existing W.B.M. base as per technical specification clause 1503
[2.EL094] EL094. CHANGE OVER SWITCH MANUAL ON LOAD FOUR POLE in SS Enclosure 400 A
[20.103.1]Development of tube well according to clause 9.3 of IS: 2800-1991 (Part-I) as amended up to date and specifications attached and as directed by the Engineer-in- charge of the work including the cost of all consumable stores, fuel, oil, compressors, pumps and machinery etc. as required for the work. 1. Compressor 450cfm x 250 psi
[20.54.4]Providing GI pipes class B marked with IS: 1239 in 3.05 m length, their threading and welding with flanges (Heavy Duty) on both sides, jointing with nuts and bolts ( ‘W’ make), rubber gaskets , lowering into Tube wells and testing including carriage, loading, unloading etc. complete in all respects to the satisfaction of Engineer-in- Charge. 4. 100 mm i/d
[20.99]Supplying and packing graded gravel in bore well of size as per ISI 4097, as amended up to date (Grade A) and specification attached with this schedule of item of work. The gravel should be free from dust, dirt or vegetable matters. Packing to be done from the housing pipe to the bottom of liner all around in the bore and will be placed after liner and housing pipes have been lowered and suitably clamped. Thickness and size of the gravel packing will be designed and directed by the Engineer-in- charge strictly as per relevant ISI.
[30.25.1]Distempering with 1st quality acrylic distemper (Ready mix) having VOC content less than 50 grams/ litre of approved brand and manufacture to give an even shade : 1. Old work (one or more coats)
[30.28.1]Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade : 1. One or more coats on old work
[30.31.1]Painting with black anti-corrosive bitumastic paint of approved brand and manufacture to give an even shade : 1. One or more coats on old work
[5.45]Dismantling old plaster or skirting raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground within 50 metres lead.
[7.21.1]Brick work with common burnt clay non-modular bricks of class designation 10.5 in foundation and plinth in: 1. Cement mortar 1:4 (1 cement : 4 coarse sand)
Maintenance of DI/MS pipe line 150-450 mm i/d (15200 Mtr) and specials along with mtc. of its civil structure, appurtenances etc. from Sec-14 to 10 No. SBS and all other works contingent thereto complete as per terms and conditions of the DNIT for a period of 2 Years.
Maintenance of DI/MS pipe line 150-450 mm i/d (15800 Mtr) and specials along with mtc. of its civil structure, appurtenances etc. from IBS at Sec-32 to 8 No. SBS and all other works contingent thereto complete as per terms and conditions of the DNIT for a period of 2 Years.
Maintenance of DI/MS pipe line 150-450 mm i/d (31500 Mtr) and specials along with mtc. of its civil structure, appurtenances etc from Sec-29 Bye pass chowk to 20 No. SBS and all other works contingent thereto complete as per terms and condition of the DNIT for a period of 2 Years.
Maintenance of DI/MS pipe line 150-450 mm i/d (9500 Mtr) and specials along with mtc. of its civil structure, appurtenances etc from Sec-29 Bye pass chowk to IBS at Sec-45 to online Booster pump to various societies like Charmwood, Lakewood, Royal Retreat etc. and all other works contingent thereto complete as per terms and conditions of the DNIT for a period of 2 Years.
Maintenance of MS/PSC pipe rising main 900 mm i/d (13600 mtr length) and specials along with mtc. of its civil structure, appurtenances, rising main from MBS at Dadasiya (Line 6) to Sec-29 Bye pass chowk to Badhkal Flyover near Sec-21C and up to B.K Chowk and all other works contingent thereto complete as per terms and condition of the DNIT for a period of 2 Years.
Maintenance of MS/PSC pipe rising main 900 mm i/d (16000 mtr length) and specials along with mtc. of its civil structure, appurtenances, rising main from MBS at Kanwra to Sec-14 and all other works contingent thereto complete as per terms and conditions of the DNIT for a period of 2 Years.
Maintenance of MS/PSC pipe rising main 900 mm i/d (7500 mtr length) and specials along with mtc. of its civil structure, appurtenances, rising main from MBS at Dadasiya (Line 7) to Sec-29 Bye pass chowk and all other works contingent thereto complete as per terms and condition of the DNIT for a period of 2 Years.
Maintenance of MS/PSC pipe rising main 900 mm i/d (18000 mtr length) and specials along with mtc. of its civil structure, appurtenances, rising main from MBS at Bhupani to IBS at Sec-32 and all other works contingent thereto complete as per terms and conditions of the DNIT for a period of 2 Years.
Operation and maintenance of 06 No. Ranney wells at Kanwra (Line 4), Bhupani (Line 5) and Dadasiya (Line 7) with pumping machinery, panel board, independent feeder, transformer, DG Set etc. Complete in all respects for a period of 2 Years.
Operation and maintenance of 1 No. Booster at STP Badshapur along with pumping machinery, panel board, independent feeder, transformer, DG Set etc. Complete in all respects for a period of 2 Years.
Operation and maintenance of 1 No. IBS (Intermediate Boosting Station) at Sec-32 along with pumping machinery, panel board, independent feeder, transformer, DG Set etc. Complete in all respects for a period of 2 Years.
Operation and maintenance of 1 No. IBS (Intermediate Boosting Station) at Sec-45 and online Booster pump near Omaxe Hills along with pumping machinery, panel board, independent feeder, transformer, DG Set etc. Complete in all respects for a period of 2 Years.
Operation and maintenance of 1 No. MBS (Main Boosting Station) at Bhupani along with pumping machinery, panel board, independent feeder, transformer, DG Set, Horticulture work in MBS premises etc. Complete in all respects for a period of 2 years.
Operation and maintenance of 1 No. MBS (Main Boosting Station) at Dadasiya (Line No.6) along with pumping machinery, panel board, independent feeder, transformer, DG Set, Horticulture work in MBS premises etc. Complete in all respects for a period of 2 Years.
Operation and maintenance of 1 No. MBS (Main Boosting Station) at Dadasiya, (Line No.7) along with pumping machinery, panel board, independent feeder, transformer, DG Set, Horticulture work in MBS premises etc. Complete in all respects for a period of 2 Years.
Operation and maintenance of 1 No. MBS (Main Boosting Station) at Kanwra along with pumping machinery, panel board, independent feeder, transformer, DG Set, Horticulture work in MBS Premises etc. Complete in all respects for a period of 2 Years.
Operation and maintenance of 10 No. Tube wells at MBS Kanwra and Village Badoli on Ranney well Line No. 4 with pumping machinery, panel board, independent feeder, transformer, DG Set, water pipe line and including 5 % spare submersible motor pump of required capacity etc. complete in all respects as per the terms and conditions of the DNIT for a period of 2 Years.
Operation and maintenance of 39 No. Tube wells at Dadasiya, Lalpur, STP Badshapur and Green belt of Sec-14 and 17 on Ranney well Line No.6with pumping machinery, panel board, independent feeder, transformer, DG Set, water pipe line and including 5% spare submersible motor pump of required capacity etc. complete in all respects as per the terms and conditions of the DNIT for a period of 2 Years.
Operation and maintenance of 4 No. Ranney wells at Dadasiya (Line 6) with pumping machinery, panel board, independent feeder, transformer, DG Set etc. Complete in all respects for a period of 2 Years.
Repair / Labour charges for repair of damaged/cracked PSC Pipeline by replacing the same with MS Pipe including welding of Machine Ends on MS pipe and collar, window cutting including Gen set, welding set, welding rods, welder, Hydra machine, JCB, Gas cutting arrangement, shifting charges of old pipes within a lead of 25 km, lighting arrangement during night time, barricading/caution tape fixing night watching, etc. complete 1 Job.
Repair, maintenance of Truss Bridge with MS pipe line including painting, welding etc. 1 Job complete for a period of 02 Years as per terms and condition of DNIT.
Servicing of DG Set 180 KVA including Engine oil, air filter, Oil filter, coolant, replacement of battery etc, 1 Job complete as per the terms and conditions of the DNIT.
Servicing of DG Set 320 KVA including Engine oil, air filter, Oil filter, coolant, replacement of battery etc. 1 Job complete as per the terms and conditions of the DNIT.
Servicing of DG Set 500 KVA including Engine oil, air filter, Oil filter, coolant, replacement of battery etc. 1 Job complete as per terms and condition of the DNIT.
Supply and Erection of aluminum conductor cable 3.5 Core, 400 Sqmm.
Supply of 800 mm dia MS Machine Ends made of 20 mm thick MS Sheet turned and machined as per site requirement. NOTE :- Machine ends will be supplied by the agency only in case of PSC pipe replacement or as per direction of Engineer-in-charge.
Supply of 800 mm ERW MS pipe for replacement of damaged PSC pipe with new 900 mm dia MS Pipe with 10 mm wall thickness with 2 coats of Epoxy paint inside and outside as per site requirement and as per the terms and conditions of the DNIT. NOTE :- MS Pipe will be supplied by the agency only in case of PSC pipe replacement or as per direction of Engineer-in-charge.
Supply of 900 mm dia MS Machine Ends made of 20 mm thick MS Sheet turned and machined as per site requirement and as per terms and condition of DNIT. NOTE :- Machine Ends will be supplied by the agency only in case of PSC pipe replacement or as per direction of Engineer-in-charge.
Supply of 900 mm ERW MS pipe for replacement of damaged PSC pipe with new 900 mm dia MS Pipe with 10 mm wall thickness with 2 coats of Epoxy paint inside and outside as per site requirement and as per the terms and conditions of the DNIT. NOTE :- MS Pipe will be supplied by the agency only in case of PSC pipe replacement or as per direction of Engineer-in-charge.
Supply of DG Set of 125 KVA Capacity on monthly hire basis. (Without Fuel and operator).
Supply of DG set of 500 KVA Capacity on monthly hire basis. (Without Fuel and operator).
Supply of DG Set of 62.5 KVA Capacity on monthly hire basis. (Without Fuel and operator).
Supplying and levelling of Good earth for filling of washed out earth in leakages / line burst pits for a period of 2 Years as per the terms and conditions of the DNIT.
M/s Lakshay and Co.
Chahar Construction Co
CHIMATECH PROJECTS PVT LTD
OM PARKASH CONT
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .