Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹8.7 LAccepted-AOC | L1 | Accepted-AOC ok | |
| 2 | L2₹9.5 L+₹87,469 (10.1%)Rejected-AOC | L2 | Rejected-AOC ok | |
| 3 | L3₹10.1 L+₹1.4 L (16.3%)Rejected-AOC 142 JAGJIVANRAM NAGAR GAROBA MAIDAN NAGPUR 440008 | NAGPUR | NAGPUR | MAHARASHTRA | 440008 | L3 | Rejected-AOC ok |
Tender Value
₹8.5 L
EMD Value
₹17,000
Closing Date
31 Aug 2020, 12:00 pmClosed
AGE (I) AF Sonegaon, Nagpur
Bldg No. P-51, 44 wing Air Force Station, Sonegaon, Nagpur 440 005
PROVISION OF FALSE CEILING IN BUILDING NO P-01 AND CERTAIN MINOR WORKS AT SONEGAON NAGPUR
2020_MES_366483_1
8342/E8
Open Tender
Civil Works
Item Rate
180 days
AGE (I) AF Sonegaon
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
AGE (I) AF Sonegaon, Nagpur
₹17,000
Yes
17 Sept 2020
4 Aug 2020
1 Sept 2020
4 Aug 2020
31 Aug 2020
18 Aug 2020
4 Aug 2020 - 17 Aug 2020
Amount
S&F Joist, channel, angle, or tee sections, fixed of any length independently, without connecting plates, etc. AFe- 290 (Gde E-165)
M &L Non asbestos building boards fixed or laid/inseted to timber/GI/Aluminium frame work with screws fixed in ceilling flat all as spd.
S&F Anodised aluminium snap grid frame of size 605mmX605mm work for false ceiling all as specified Note:- Cost of making frame work for lighy fitting grills difusers cutouts etc is deemed to be incl in the quoted rate.
S&F frame work such as grills, grating etc with ends of bars shouldered and or rivetted or forged into spikes, framed guard bars, barred iron doors, ladders etc and similar wks conforming to Fe-290 Gd E-165 .
Hangers 6 mm dia. G.I. (upto 1200mm length) adjusting level fixed to roof slabs by means of ceilling cleats made out of G.I. flat 40 x 3 mm size 60mm long and expansion hold fasteners 12.5mm dia. 40mm long complete all as specified
Taking down cement or cement lime palstering of any descrirption etc including raking out joints , hacking for key, scrubbing down with water etc.
M&L for rendering 15mm thick on fair faces of brick work or concrete surface in cement mortar 1:6 to be finished even smooth with out using extra cement as directed and specified by engineer in chanrge
M&L for preparation of 3 mm thick wall care putty on wall
M&L for preparing new plastered surfcaes and applying two caot of OBD all as specified and directed
Cutting holes in brick walls in built in lime mortar and stone walls for inserting holdfasts and making good dismantled portion in cement mortar 1:3 or cement concrete 1:2:4 Type B-1 as required including 3 coat of white wash on newely plastered surfaces on wall complete all as specified and directed by Engineer in charge.
M&L Preparation to new steel surfaces of any description over 10 cm in width or girth not other wise described and applying two coat of Synthetic enamel paint over a redoxide etc.
M/L for factory made solid pvc moulded door shutter 28 to 30 mm thick stlles with 2,4 or 6 raised paneal design with 2mm thick mouled pvc sheet on the front race & 2mm plain coolur pvc sheet on back face supplying & fixing in frame at site but 2mm thick moulded prelam pvc sheet on the front race & 2mm prelam pvc sheet on back face as per specification and directed byEIC at site.
S & F mild steel medium weight could rolled butt hinge 100mm size.
S & F Aluminium Handle of 150mm size cast type anodised
Aluminium anodised, barrel tower bolts of extruded section and fixed (150mm long)
S&F Mild steel sliding door bolts 300 mm long, plate type, stove enamelled black,300mm with bright bolt not less than 12mm dia with and including a minimum of 6 bolts and nuts, four on bolt plate and two on staple plate and fixed
S&F Pressed steel frames for doors size 125x60mm with one or more rebates including necessary fixing lugs, hinges, lock strike plate etc., complete, as specified,supplied and fixed
S&F for Pre-painted galvalume aluminium zinc coating GI based plain steel sheet 0.50mm of an colour having tensile strength of 550Mpa as in roof covering/wall cladding/Eaves board, fixed with self tapping screws as specified
M&L for 2ndclass hard wood plain,solid straight chowkhats and frames wrought framed rebated on the solid rounded or chamfered put together with glue pinned at joints supplied and fixed.
M &L for PVC concealed conduit point wiring with 1.5 square mm nominal area stranded copper conductor PVC insulated single core cable1100 Volts grade conforming to IS694 part-i draw in20 mm size PVC conduit in concealed including 600volts grade 1.5square mm copper stranded single core cable green color PVC insulatedfor contineuous earthing wire with complete chesscutting ,S/F of 20 mm dia PVC conduit with elbow,bends,couplers,tee, sucken boxes pressed steel box mounting fitting/junction boxes etc covered the conduit with cement mortor after drawing of electric cables and makig good of distrubed surfaces and match with existing shade of wall/roof all as directed by Enginner -in -charge. For the following:- (a) One light point controlled by one switch
(b) One Fan/Exhaust Fan controlled by one switch
(c) One three pin 5 Amps switch socket outlet on independent board
(d) One three pin 5 Amps switch socket outlet on same board
ditto- all as per item No.20 here in before but point wiring with 2.5.0 sqmm multistrandard copper cable for 5 Pin 15 Amp switch socket combination on Independent board with one run of 1.5 sq mm multistranded copper cable green colour for earth continuity conductor complete .
S&F switch piano, flush type single pole,5 Amps, 240 Volts Ac complete .
S&F ceiling rose surface backlite, 65x50mm, three terminals, 5 Amps,240 Volts AC
S&F switch socket combination 5 Pin,5 Amps,240 Volts, flush type complete.
S&F switch socket combination 2 IN 1, 3 PIN,5 and 15 flush type universal ,240 Volts, complete .
Supply and fix LED tube light fitting capacity 16 watt fixed on wall/surface / ceiling with all accessories tube,driver,with surge protector completerewired with multistranded copper cable & connecting to ceiling rose with 3 core ,multistranded flexible copper cable Make CGCta No-LCCLB16-CDL/wipro/CG/Havells/philips/Bajaj.
S & F 36Watt Recessed LED perforated Single Window modern Designed enabled by advanced LFD light.it blandes into celing plane &maintain Uniform luminance across aperature to enhance visual comfort ceiling tile provided with a drop down acrylic diffser suitable for 600X600 MM ceiling incluiding extra frame for fixing at POP/ Gysum Ceiling mounted version including LED light complete. The 36W system shall be operating at 220-240v AC supply having internal driver. IP20, surge protection 2KV, ambient tempretaur (-) 20 to 45 degree C, frequency 50 to 60 Hz. . PF should be grater than 0.95, THD < 10%. Individual LED's should not be visible for glare free output, and connection up to tube light fitting with connecting up with copper 3 core flexible cord of minimum 1.5 Sqmm size and testing complete, including taking down old unserviceable fitting all as specified and as directed Make : CG LCTLSN-36-CDLCDL equivalent in Havells , Wipro.
S & F Fan regulator stepped type electronic fan regulator flush type on the phenolic laminated sheet as directed.
S & Lay concealed sub main wiring with two single core cable of 6 sqmm PVC insulated , 1100 volt grade as per IS 694, with multistranded copper conductor in and including rigid PVC conduit (ISI Marked) including earthing wire of pvc insulated stranded 4 sq mm cable ,chess cutting including S/F of 20 mm dia PVC conduit with elbow,bends,couplers,tee, sucken boxes pressed steel box mounting fitting/junction boxes etc covered the conduit with cement mortor after drawing of electric cables and makig good of distrubed surfaces and match with existing shade of wall/roof all as directed by Enginner -in -charge.
S&F sheet metal enclosure DB 4 way 240Volt with bus bar semi conceled type with necessary connection model no-Legrand DB with incoming slot for MCCB as incomer Make-egrand,Havells,Indoasian.
S&F sheet metal enclosure DB 8 way 240Volt with Bus bar semi conceled type with necessary connection model no-Legrand DB with incoming slot for MCCB as incomer Make-egrand,Havells,Indoasian.
S&F MCBs 10 Amp with necessary connection in DB box
S&F MCBs 20 Amp DP with necessary connection in DB box
S&F isolator TPN 63A with necessary connection in DB box
S&F isolator DP 40A with necessary connection in DB box
Supply , Laying , connecting,charging, testing and ccommissioning LT cable electric , XLPE insulated, armoured , heavy duty, electric cable 1100 volt grade with stranded aluminum conductor laid in trenches/ducts/fixed to wall /roofs/ poles with clamp/shaddle all as specified of size as under;- (a) 50sq mm 3.5 core
(b) 35sq mm 3.5 core
S & F Splite AC 2 TR capacity not less than 5star rating,out door unit installed on 2No angle iron anchor pickets with nut bolts arrangement & inner unit of A/C in side the room wall surface with suitable space for further maintenance including necessary gas charging / topping up with soldering of copper tubes including exposed nitrile ruber and refrigerent piping & proper saddling , clamping & covering all as directed by Enger-in-charge.Make-Blue Star/LG/Daikin
M &L for PVC surface conduit sub main wiring with 02run of 06 square mm nominal area stranded copper conductor single core PVC insulated ,PVC sheatheated cable1000 Volts grade draw in PVC conduit including 1000volts grade 4 square mm copper stranded single core cable PVC insulated for contineuous earthing wire with complete ,s/f of PVC conduit with elbow,bends,couplers,tee etc complete
S&Fsemi grouting industrial socket & plug powder coated made of CRCA sheet complete box comprised with MCB, SP 32 AMP 12 KAMP reputuring cap.
M &L for PVC casing capping surface point wiring with 1.5 square mm nominal area stranded copper conductor PVC insulated single core cable1100 Volts grade conforming to IS694 part-i including 600volts grade 1.5square mm copper stranded single core cable green color PVC insulatedfor contineuous earthing wire complete with PVC casing capping,elbow,bends,couplers,tee,switch mounting box top covered with white hylam sheet,fixing screws mounting fitting/junction boxes etc and makig good of distrubed surfaces and match with existing shade of wall/roof all as directed by Enginner -in -charge for the following:- (a) One Fan/Exhaust Fan controlled by one switch
S&F ceiling rose surface backlite, 65x50mm, three terminals, 5 Amps,240 Volts AC
S & F Exhaust fan 230Volts 300MM single phase sweep with louvers & necessary wall cutting /demolition of bricks & other chissling work & finished good of work with complete. Make -CG/ALMONARD/BAJAJ
S & F Exhaust fan 230Volts 450MM single phase sweep with louvers & necessary wall cutting /demolition of bricks & other chissling work & finished good of work with complete. Make -CG/ALMONARD/BAJAJ
S & F single pole and neutral sheet steel powder coated Distribution board for MCBs fitted with out bus bar , Neutral link ,Earth Bar and Din rail suitable for use on 240 V, 50 Hz supply SP&N DB system 2 ways complete all as directed.
S&F MCBs 20 Amp sp with necessary connection in DB box
S&F MCBs 10 Amp with necessary connection in DB box
S& F Twin AC Controller suitable for 2TR AC's 2Nos 230V AC ,Power Relays & with trip setting under 120-210 V & Over 240- 300V ,Over Load 5-20 Amp settable by Keys & display(default set-20A,current & Room temp Display Cyclic Time delay 3Min to 24hrswith 2No contacts.
S& F Twin AC Controller suitable for 1.5TR AC's 2Nos 230V AC ,Power Relays & with trip setting under 120-210 V & Over 240- 300V ,Over Load 5-20 Amp settable by Keys & display(default set-20A,current & Room temp Display Cyclic Time delay 3Min to 24hrswith 2No contacts.
Excavating over areas, n exc 1.5 m deep and getting out in soft/loose soil
Excavating over areas, n exc 1.5 m deep and nexc 3.0 m deep and getting out in hard/ dense soil
Excavating in trenches, n exc 1.5 m deep and nexc 1.50 m wide and getting out in soft/ loose soil all as specified
Cement concrete type D2 1:4:8 (40 mm graded aggregate in foundations, filling, and mass concrete , bed for soak well and below wall of septic tank
M&L Brick work with subclass ‘B’ bricks, straight or curved on plan exc 6m mean radius, built in CM (1:6) all as specified and directed by Eng-in-charge
Liquid water proofing compound
M&L for Rendering 15 mm thick on fair faces of brick work or concrete surfaces in cement mortar 1:6 to be finished even smooth without using extra cement as specified and directed by Eng-in-charge.
M &L providing precast cement concrete type B-1 (1:2:4) using 20 mm graded stone aggregate as in cover slab set in cement mortar (1:6) incl necessary formwork as required complete all as specified and directed.
RCC B-1 (1:2:4) 20 mm graded agg as in walls, retaining walls, basement walls, ballast walls, and slab like any thickness
M&L rendering 15mm thick on brickwall or concrete surface in cement mortar 1:4 finished even and smooth wwithout using extra cement complete all as specified and directed
Formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work not exc 200 m thick (horizontal or sloping)
Mild steel bars 5mm dia and over upto and incl 10 mm dia cut to length ,bent to shape required, incl cranking, bending, spirally for hooping for columns , hooking ends and binding with the including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips cover slab
M&L salt-glazed stoneware 150 mm dia drain pipes laid in trenches and jointed as specified
Returning filling in trenches including spreading levelling and well ramming with water complete nexc 25 cm thick in each layer in soft/ loose soil
M&L PCC 1:3:6 type C2 using 40 mm graded stone aggregate for concrete bed to drain pipes incl packing under and haunding against the sides of pipe, after they tested for 150 mm dia pipe
Removing Excavated material exc 250 m nexc 500 m distance and depositing where directed at a level nexc 1.5 m above the starting point complete all as specified and directed
White washing two coats incl preparation of walls
Removing excavated material n exc. 50m and depositing where directed at a level n exc. 1.5 m above the starting point complete all as specified and directed
M&L for Moorum/red bajri filling in floors or pavings, laid in layers n exc. 15 cm thick, spread, levelled and rammed including watering as directed by EIC
M&L for hardcore of gauge not exceeding 63mm,deposited, spred and levelled in layer not exceeding 15cm thick, watered and rammed to true surface.
M &L 100 mm thick cement concrete type D-2 (1:4:8) 40 mm graded aggregate as in sub base
M & L for shingle filling in floors or pavings, laid in layers nexc 15 cm thick , spread, levelled and blinded with earth and rammed incl watering complete all as specified and directed
M&L for Machine pressed precast conctete interlocking paver block 60 mm thickness, M-35 grade with grey cement & pigment any shape and size confirming to IS 15658- 2006 over sand cushoning complete all as specified and directed .Note - Sand shall be measured and paid separately
M&L for PCC (1:2:4) type B-1, using 20 mm graded stone aggregate as in kerb or side of path and the like incl weathering, slightly rounded or chamfered angles and throating complete all as specified and directed
M/s M.G. Hargunani
karambir constructions
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .