Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Fee/PreQual/Technical/Finance | Admitted-Fee/PreQual/Technical/Finance |
| 2 | Admitted-Fee/PreQual/Technical/Finance | Admitted-Fee/PreQual/Technical/Finance |
| 3 | Not Admitted-Fee/PreQual/Technical/Finance HOUSE NO 214 WARD NO 2 TEHSIL SUJANPUR DISTT HAMIRPUR HP | HAMIRPUR | HIMACHAL PRADESH | 174304 | Not Admitted-Fee/PreQual/Technical/Finance Not qualified for AOC |
Tender Value
₹22.9 L
EMD Value
₹42,000
Closing Date
28 Sept 2020, 5:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
XEN Elect Division No II
XEN Elect Division No II HPPWD Shimla-2
Providing electrical installation therein
2020_PWD_40590_1
ED.II.GA.Tender/20-21-4146-47 dated 08.09.2020
Open Tender
Electrical Works
Item Rate
365 days
Shimla
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
EE Elect Division No II
₹42,000
29 Sept 2020
16 Sept 2020
29 Sept 2020
16 Sept 2020
28 Sept 2020
16 Sept 2020
120 days
Amount
Wiring for light point / fan point / exhaust fan / call bell point with 1.5 Sq. mm. PVC insulated heat resistant flame retardant (HRFR) and low smoke single core (flexible) copper conductor cable in surface/recessed steel conduit and earthing the light point with 1.5 Sq.mm. HRFRLS/PVC insulated single core copper conductor cable as required.
Group C.
Wiring for circuit/sub-main with following size PVC insulated heat resistant flame retardant (HRFR) and low smoke single core (flexible) copper conductor cable in surface/recessed steel conduit along with 1 No.HRFRLS/PVC insulated single core copper conductor cable of same size for earthing as required.
2x1.5 Sq. mm.
2x2.5 Sq. mm.
Wiring for power plug with 2x4 Sq. mm. PVC insulated heat resistant flame retardant (HRFR) and low smoke single core (flexible) copper conductor cable in surface /recessed steel conduit along with 1 No.4 Sq.mm. HRFRLS/PVC insulated single core copper conductor cable for earthing as required.
Wiring for power plug with 4x4 Sq. mm. PVC insulated heat resistant flame retardant (HRFR) and low smoke single core (flexible) copper conductor cable in surface/recessed steel conduit along with 2 No.4 Sq.mm. HRFRLS/PVC insulated single core copper conductor cable for earthing as required.
Wiring for circuit/sub-main with following size PVC insulated heat resistant flame retardant (HRFR) and low smoke single core (flexible) copper conductor cable in surface/recessed steel conduit along with 1 No.HRFRLS/PVC insulated single core copper conductor cable of same size for earthing as required.
2x10 Sq. mm.
2x16 Sq. mm
Supplying and fixing metal box of 100mmx100mmx60mm deep (nominal size) on surface/recess with suitable size phenolic laminated sheet cover in the front including providing and fixing 5 pin 5/6 amps socket outlet and 5/6 amps, piano type switchconnections, painting etc. as required.
Supplying and fixing metal box of 180mmx100mmx60mm deep (nominal size) on surface/recess with suitable size phenolic laminated sheet cover in the front including providing and fixing 6 pin 15/16 amps socket outlet and 15/16 amps, piano type switch, connections, painting etc. as required.
Supplying and erection of 6 amps. to 32 amps. rating, 10 KA breaking capacity, 240 volts, 'C' curves, miniature circuit breaker of following poles in the existing MCB DB complete with connections etc. as required:-Single pole. Cat-A.
Supplying and erection of 40/50/63 amps rating, 10 KA breaking capacity, 240 volts, 'C' curves, miniature circuit breaker of following poles in the existing MCB DB complete with connections etc. as required:-Double pole. Cat-A.
Supplying and fixing following rating, double pole (single phase & neutral) 240 volts, residual current circuit breaker (RCCB), having a sensitivity current up to 300 miliampers in the existing MCB DB complete with connections, testing and commissioning etc. as required.
40 Amp. Cat A
63 Amp. Cat A
Providing, laying and fixing of one No. aluminium conductor, PVC insulated and PVC sheathed, armoured/XLPE power cable, working voltage 1100 volts grade on surface etc. of the required size:-
Armoured cable 16 sq. mm (four core)
Providing and fixing following rating and breaking capacity MCCB in the existing cubical panel board including drilling holes in the cubicle panel, making connections, etc. as required.
100 Amp. -16 KA
Providing and installation of stationary storage type Electric water heater (Geyser) of various sizes by means of Expansion-bolts with nuts and washers, including embedding of expansion-bolts in the wall, providing and fixing of Non-return valve, Dead weight safety valve, 2 No C.P. connection rods 18" long, making good the damages, electrical connections, safety valve connections, testing and commissioning etc. as required:-
25 Liter capacity water heater (Cat-A)
15 Liter capacity water heater (Cat-A)
Supplying and fixing metal box of 250mmx200mmx60mm deep (nominal size) on surface/recess with suitable size phenolic laminated sheet cover in the front including providing and fixing 5 pin 5/6 amps socket outlet and 5/6 amps, piano type switch -3 nos and 1 no 15 Amp. switch and socket i/c making necessary connections, painting etc. as required.
Supplying and fixing of fancy wall bracket 12 watt LED type of all sizes and shapes, complete with all accessories including making connections, testing etc. as required.
Supplying and fixing of following way SEGREGATED,triple pole and neutral,IP-43 double door sheet steel MCB distribution board,415 volts, on surface/reces,with provision to mount 4 module MCCB incomer,4 module sub-incomer in each phase and SP MCBs as outgoing,complete with tinned copper bus -bar,wire-set,neutral link,earth bar,din-bar,detachable gland plate,cable,identification labels interconnections ,phosphatizedand powder painted,including earthing etc. as required :Make :L&T,Schneider,Siemens,ABB,Legrand,C&S etc.
6 way, MCCB+12+24 DD
8 way, MCCB+12+24 DD
12 way, MCCB+12+24 DD
Providing and installation of light duty,plastic body,ventilating fan of following sizes in the existing opening,by means of suitable rag-bolts/nuts,including making the hole to suit the size of the above fan,making good the damages,connections,testing and commissioning etc. as required complete in all respects to the satisfaction of the Engineer-in-charge
Ventilating Fan ,Light Duty,(Plastic body) 250mm sweep
Providing and installation of following type of surface / recess mounting slim square / round type LED Downlight with two years warranty in white finish with anti glare polycarbonate diffuser and separated energy efficient constant current, non-integral, electronic driver, suitable for input voltage: AC 220-240V, 50/60 Hz complete with all accessories, including making suitable cut-out in the existing ceiling, connections, testing and commissioning etc. as required. Make:- Philips, Twinkle, GE or any other approved by Engineer-in-Charge.
LED Downlight 36 Watt
LED Downlight 22 Watt
LED Downlight 12 Watt
Providing and installation of following type of ultra slim decorative LED batten with extruded aluminium heat sink,with anti glare polycarbonate diffuser and energy efficient constant integral,electronic driver,suitable for input voltage:AC 220-240 V,50/60Hz,complete with all accessories,including mounting clips & loop in loop out wire,connections,testing and commissioning etc.as required with two years warranty. Make:Philips,GE,Twinkle or any other approved by Engineer-in-Charge.
LED Batten Light 20 W 1200mm
M/s Naresh Elecric Works
stage.html
html • 0.02 MB
finance_59878.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .