Loading…
Loading…
| # | Company | Amount |
|---|---|---|
| 1 | ₹33.6 Cr HOUSE NO 1 PLOT NO 27 NAYAPALLI VIP COLONY IRC VILLAGE BHUBANESHWAR KHORDA ODISHA 751012 | ₹33.6 Cr |
Tender Value
₹36.4 Cr
EMD Value
₹36.4 L
Closing Date
21 Oct 2025, 11:00 amClosed
Construction of Eklavya Model Residential School (EMRS) at Darbha, District- Bastar, Chhattisgarh
NBCC/CPG/EMRS2/Darbha/Bastar/2025/518
NBCC/CPG/EMRS2/Darbha/Bastar/2025/518
Open Tender-Domestic
Civil Works General
Bastar, Chhattisgarh
₹59,000
₹36.4 L
20 Sept 2025
20 Sept 2025
21 Oct 2025
21 Oct 2025
30 Jan 2026
TOTAL AMOUNT WITH CORRECTION FACTOR (0.973) AS PER OM OF CPWD
Grand Total (DSR+ Non DSR) (A):- 36,37,08,165
GRAND TOTAL (CIVIL WORKS) (In Rs) 28,07,87,467.02 31,94,286.40
GRAND TOTAL (PLUMBING WORKS) (In Rs) 1,25,60,244.76 20,97,890.50
GRAND TOTAL (FIRE FIGHTING WORKS) (In Rs) 11,07,572.30 2,06,729.69
GRAND TOTAL (ELECTRICAL WORKS INTERNAL) (In Rs) 1,10,02,782.00 22,96,639.76
GRAND TOTAL (ELECTRICAL WORKS EXTERNAL) (In Rs) 32,31,424.00 83,37,652.30
GRAND TOTAL (KITCHEN & PANTRY) (In Rs) - 23,81,086.18
GRAND TOTAL (FURNITURE) (In Rs) - 1,37,22,520.72
ABSTRACT OF COST
S. No. Description Unit Quantity Rate Amount (In Rs)
1.0 2 Earth Work
1.01 2.1 Earth work in surface excavation not exceeding 30 cm in depth but exceeding 1.5
m in width as well as 10 sqm on plan including getting out and disposal of
excavated earth upto 50 m and lift upto 1.5 m, as directed by Engineer-in- Charge:
1.02 2.6 Earth work in excavation by mechanical means (Hydraulic excavator)/manual
means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on
plan) including getting out and disposal of excavated earth lead upto 50m and for -
all lift as directed by Engineer-in-charge.
1.03 2.7 Earth work in excavation by mechanical means (Hydraulic excavator)/manual
means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on
plan) including getting out and disposal of excavated earth lead upto 50m and lift -
upto 1.5m, as directed by Engineer-in-charge.
2.7.3 Hard rock (blasting prohibited) Cum - 1,184.30 -
1.04 2.8 Earth work in excavation by mechanical means (Hydraulic excavator) / manual
means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm
on plan), including dressing of sides and ramming of bottoms, l for all ift, including -
getting out the excavated soil and disposal of surplus excavated soil as directed
within al lead of 50m.
1.05 2.9 Excavation work by mechanical means (Hydraulic excavator)/ manual means in
foundation trenches or drains (not exceeding 1.5m in width or 10 sqm on plan),
including dressing of sides and ramming of bottoms, lift upto 1.5m, including -
getting out the excavated soil and disposal of surplus excavated soils as directed
within a lead of 50m.
2.9.3 Hard rock (blasting prohibited) Cum 58.55 1,258.60 73,690.69
1.06 2.25 Filling available excavated earth (excluding rock) in trenches, plinth, sides of
foundations etc. in layers not exceeding 20cm in depth, consolidating each
deposited layer by ramming and watering, lead upto 50m and for all lift.
1.07 2.25 (a) Excavating, supplying, stacking and filling of local earth (including royalty) by
mechanical transport upto a lead of 5km also including ramming and watering of
the earth in layers not exceeding 20cm in foundation trenches, plinth, sides of
foundation etc. complete for all lift.
1.08 2.27 Supplying and filling in plinth with sand under floors, including watering,
ramming, consolidating and dressing complete.
1.09 2.31 Clearing jungle including uprooting of rank vegetation, grass, brush wood, trees
and saplings of girth up to 30 cm measured at a height of 1 m above ground level
and removal of rubbish upto a distance of 50m outside the periphery of the area
1.10 2.36 Extra for levelling & neatly dressing of disposed soil completely as directed by
Engineer-in-charge.
Total of sub-head (1.0) 59,71,853.90
2.0 4 Concrete Work -
2.01 4.1 Providing and laying in position cement concrete of specified grade excluding the
cost of centering and shuttering - All work up to plinth level :
4.1.10 1:5:10 (1 cement : 5 coarse sand (zone-III) derived from natural sources: 10 graded
stone aggregate 40 mm nominal size derived from natural sources)
Derived from Providing and placing in position 400 micron thick low density polyethylen
basic rates of (LDPE) black sheet under base of RCC grade slab. The overlaps at end and side
DSR 2021 joints of PVC sheet shall not be less than 100mm wide and shall be pasted to each Sqm 2,751.00 108.80 2,99,308.80
other with bitumen @ 1.7 kg/sqm. (Note: Superfical area of sheet shall be
measured for payment)
2.02 Derived from Providing and laying broken autoclaved aerated cement (AAC) blocks and/or bats
basic rates of (light weight, having density 550-650 kg/m3) of nominal size 25mm to 65mm in the
sunken portion of toilets upto floor five level all complete as per the direction of
Engineer-in-charge.
S. No. Description Unit Quantity Rate Amount (In Rs)
2.03 4.2 Providing and laying cement concrete in retaining walls, return walls, walls (any
thickness) including attached pilasters, columns, piers, abutments, pillars, posts,
struts, buttresses, string or lacing courses, parapets, coping, bed blocks, anchor -
blocks, plain window sills, fillets, sunken floor etc., up to floor five level,
excluding the cost of centering, shuttering and finishing:
4.2.3 1:2:4 (1 Cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded
stone aggregate 20 mm nominal size derived from natural sources)
2.04 4.3 Centering and shuttering including strutting, propping etc. and removal of form
4.3.1 Foundations, footings, bases for columns Sqm 896.80 332.60 2,98,276.04
2.05 4.10 Providing and laying damp-proof course 40mm thick with cement concrete 1:2:4 (1
cement : 2 coarse sand (zone-III) derived from natural sources: 4 graded stone Sqm 563.00 370.85 2,08,788.55
aggregate 12.5mm nominal size derived from natural sources)
2.06 4.13 Providing & applying a coat of residual petroleum bitumen of grade of VG-10 of
approved quality using 1.7kg per square metre on damp proof course after cleaning
the surface with brushes and finally with a piece of cloth lightly soaked in kerosene
2.07 4.17 Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 coarse
sand (zone-III) derived from natural sources : 6 graded stone aggregate 20 mm
nominal size derived from natural sources) over 75mm thick bed of dry brick
ballast 40 mm nominal size, well rammed and consolidated and grouted with fine
sand, including necessary excavation, levelling & dressing & finishing the top
Total of sub-head (2.0) 90,69,227.61
3.0 5 Reinforced Cement Concrete -
3.01 5.9 Centering and shuttering including strutting, propping etc. and removal of form for :
5.9.1 Foundations, footings, bases of columns, etc. for mass concrete Sqm 2,919.66 332.10 9,69,618.42
5.9.2 Walls (any thickness) including attached pilasters, butteresses, plinth and string
5.9.3 Suspended floors, roofs, landings, balconies and access platform Sqm 9,897.00 766.55 75,86,545.35
5.9.4 Shelves (Cast in situ) Sqm 235.00 766.55 1,80,139.25
5.9.5 Lintels, beams, plinth beams, girders, bressumers and cantilevers Sqm 14,769.50 608.35 89,85,025.33
5.9.6 Columns, Pillars, Piers, Abutments, Posts and Struts Sqm 8,654.00 804.25 69,59,979.50
5.9.7 Stairs, (excluding landings) except spiral-staircases Sqm 297.00 657.70 1,95,336.90
5.9.14 Extra for shuttering in circular work(20% of respective centering and shuttering
5.9.15 Small lintels not exceeding 1.5 m clear span, moulding as in cornices, window sills,
string courses, bands, copings, bed plates, anchor blocks and the like
5.9.16 Edges of slabs and breaks in floors and walls -
5.9.19 Weather shade, Chajjas, corbels etc., including edges Sqm 1,115.00 821.35 9,15,805.25
3.02 5.11 Extra for additional height in centering, shuttering where ever required with
adequate bracing, propping etc., including cost of de-shuttering and decentering at
all levels, over a height of 3.5 m, for every additional height of 1 metre or part
thereof (Plan area to be measured).
5.11.1 Suspended floors, roofs, landing, beams and balconies (Plan area to be measured)
3.03 5.16 Providing, hoisting and fixing above plinth level up to floor five level precast
reinforced cement concrete in shelves, including setting in cement mortar 1:3
(1cement : 3 coarse sand), cost of required centering, shuttering and finishing with
neat cement punning on exposed surfaces but , excluding the cost of reinforcement, Cum 50.00 18,038.45 9,01,922.50
with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3
graded stone aggregate 20 mm nominal size derived from natural sources).
5.22 Steel reinforcement for R.C.C. work including straightening, cutting, bending,
placing in position and binding all complete upto plinth level.
5.22.6 Thermo-Mechanically Treated bars of grade Fe-500D or more. kg 2,12,376.00 89.65 1,90,39,508.40
5.22A Steel reinforcement for R.C.C. work including straightening, cutting, bending,
placing in position and binding all complete above plinth level.
5.22A.6 Thermo-Mechanically Treated bars of grade Fe-500D or more. kg 5,20,071.79 89.65 4,66,24,435.60
5.23 Smooth finishing of the exposed surface of R.C.C. work with 6 mm thick cement
mortar 1:3 (1 Cement : 3 fine sand).
5.30 Add for plaster drip course/ groove in plastered surface or moulding to R.C.C.
S. No. Description Unit Quantity Rate Amount (In Rs)
Providing and laying in position ready mixed or site batched design mix cement
concrete for reinforced cement concrete work; using coarse aggregate and fine
aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland
/Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to
accelerate / retard setting of concrete, to improve durability and workability
without impairing strength; including pumping of concrete to site of laying, curing,
carriage for all leads; but excluding the cost of centering, shuttering, finishing and
reinforcement as per direction of the engineer-in-charge; for the following grades
of concrete. Note: Extra cement up to 10% of the minimum specified cement
content in design mix shall be payable separately. In case the cement content in
design mix is more than 1.10 times of the specified minimum cement content,
the contractor shall have discretion to either re-design the mix or bear the cost
of extra cement.
5.33.1 All works upto plinth level
5.33.1.1 Concrete of M25 grade with minimum cement content of 330 kg /cum Cum 2,090.00 8,683.80 1,81,49,142.00
5.33.1.2 Concrete of M30 grade with minimum cement content of 350 kg /cum 167.00 8,823.35 14,73,499.45
5.33.2 All works above plinth level upto floor V level.
5.33.2.1 Concrete of M25 grade with minimum cement content of 330 kg /cum Cum 3,380.00 8,964.75 3,03,00,855.00
5.33.2.2 Concrete of M30 grade with minimum cement content of 350 kg /cum Cum 154.00 9,106.35 14,02,377.90
3.05 Derived from Deduct for providing M-20 grade concrete instead of M-25 grade machine batched
DSR 2021 and machine mixed design mix for reinforced cement concrete work (Note:-
basic rates Cement content considered in M-25 and M-20 is @ 330 kg/cum and 300 kg/cum
respectively) (this item is applicable for RCC in grade slab only)
3.06 5.35 Add for using extra cement in the items of design mix over and above the specified
cement content therein.
3.07 5.43 Providing and fixing in position Stainless steel Grade 304 plate-1.0 mm thick as per
design for expansion joints.
3.08 5.44 Providing and fixing of expansion joint system related with floor location as per
drawings and direction of Engineer-In-Charge. The joints system will be of
extruded aluminum base members, self aligning / self centering arrangement and
support plates etc. as per ASTM B221-02. The system shall be such that it provides
floor to floor /floor to wall expansion control system for various vertical localtion
in load application areas that accommodates multi directional seismic movement -
without stress to it's components. System shall consist of metal profiles with a
universal aluminum base member designed to accommodate various project
conditions and finish floor treatments.
The cover plate shall be designed of width and thickness required to satisfy projects
movement and loading requirements and secured to base members by utilizing
manufacturer’s pre-engineered self- centering arrangement that freely rotates /
moves in all directions. The Self - centering arrangement shall exhibit circular
sphere ends that lock and slide inside the corresponding aluminum extrusion cavity
to allow freedom of movement and flexure in all directions including vertical -
displacement. Provision of Moisture Barrier Membrane in the Joint System to have
watertight joint is mandatory requirement all as per the manufactures design and as
approved by Engineer -in-Charge. (Material shall confirm to ASTM 6063).
5.44.1 Floor Joint of 100 mm gap Metre 119.00 5,800.15 6,90,217.85
3.09 5.45 Providing and fixing of expansion joint system related with wall joint (internal/
external) location as per drawings and direction of Engineer-In- Charge. The joints
shall be of extruded aluminum base members, self aligning / centering arrangement
and support plates as per ASTM B221- 02. The material shall be such that it
provides an Expansion Joints System suitable for vertical wall to wall/ wall to
corner application, both new and existing construction in office Buildings & -
complexes with no slipping down tendency amongst the components of the Joint
System. The Joint System shall utilize light weight aluminum profiles exhibiting
minimal exposed aluminum surfaces mechanically snap locking the multicellular to
facilitate movement. (Material shall confirm to ASTM 6063.)
3.10 5.46 Providing and fixing of expansion joint system of approved make and manufactures
for various roof locations as per approved drawings and direction of Engineer-In-
Charge. The joints shall be of extruded aluminum base members with, self aligning
and self centering arragement support plates asper ASTM B221-02. The system
shall be such that it provides watertight roof to roof/roof to corner joint cover
expansion control system that is capable of accommodating multidirectional -
seismic movement without stress to its components. System shall consist of metal
profile that incorporates a universal aluminum base member designed to
accommodate various project conditions and roof treatments.
S. No. Description Unit Quantity Rate Amount (In Rs)
The cover plate shall be designed of width and thickness required to satisfy
movement and loading requirements and secured to base members by utilizing
manufacturer’s preengineered self-centering arrangement that freely rotates / moves
in all directions. The Self centering arrangement shall exhibit circular sphere ends
that lock and slide inside the corresponding aluminum extrusion cavity to allow
freedom of movement and flexure in all directions including vertical displacement. -
The Joint System shall resists damage or deterioration from the impact of falling
ice, exposure to UV, airborne contaminants and occasional foot traffic from
maintenance personnel. Provision of Moisture Barrier Membrane in the Joint
System to have water tight joint is mandatory requirement. (Material shall confirm
5.46.1 Roof Joint of 100 mm gap Metre 87.00 5,424.20 4,71,905.40
3.11 19.19 Providing and fixing in position pre-cast R.C.C. manhole cover and frame of
required shape and approved quality
19.19.1.1 Rectangular shape 600x450mm internal dimensions Each 2.00 1,255.25 2,510.50
Total of sub-head (3.0) 14,95,15,142.10
4.0 6 Masonry Work -
4.01 6.1 Brick work with common burnt clay F.P.S. (non modular) bricks of class
designation 7.5 in foundation and plinth in:
6.1.2 Cement mortar 1:6 (1 cement : 6 coarse sand) Cum 313.00 6,658.25 20,84,032.25
6.1.2 Brick work with non modular fly ash bricks conforming to IS:12894, class
(Modified) designation 10 average compressive strength in foundation and plinth in: Cum 239.00 6,995.33 16,71,883.87
a) Cement mortar 1:6 (1 cement : 6 coarse sand)
4.02 6.4 Brick work with common burnt clay F.P.S. (non modular) bricks of class
designation 7.5 in superstructure above plinth level up to floor V level in all -
shapes and sizes in :
6.4.2 Cement mortar 1:6 (1 cement : 6 coarse sand) Cum 440.00 8,288.40 36,46,896.00
4.03 6.38 Providing and laying Autoclaved Aerated concrete (AAC) blocks masonry 100 mm/
125 mm thick with Grade-I AAC blocks of density 551 to 650 kg/ cum conforming
to IS: 2185 (Part 3) in super structure above plinth level up to floor V level in
cement mortar 1:4 (1 cement : 4 coarse sand). The rate includes providing and
placing in position 2 Nos 6 mm dia M.S. bars at every third course of masonry
4.04 6.47 Providing and laying Autoclaved Aerated concrete (AAC) blocks masonry
150mm to 300mm thick AAC with Grade-I blocks of density 551 to 650 kg/ cum
conforming to IS: 2185 (Part 3) in super structure above plinth level up to floor V
level with RCC band at sill level and lintel level with approved block laying Cum 2,115.00 7,213.50 1,52,56,552.50
polymer modified adhesive mortar all complete as per direction of Engineer-in-
Charge. (The payment of RCC band and reinforcement shall be made for
4.05 6.13 Half brick masonry with common burnt clay F.P.S. (non modular) bricks
of class designation 7.5 in superstructure above plinth level up to floor -
6.13.2 Cement mortar 1:4 (1 cement :4 coarse sand) Sqm 1,189.60 1,018.05 12,11,072.28
4.06 6.15 Extra for providing and placing in position 2 Nos 6mm dia. M.S. bars at every third
course of half brick masonry.
Total of sub-head (4.0) 2,63,28,866.16
5.0 Stone Work
5.01 7.1 Random rubble masonry with hard stone in foundation and plinth including
levelling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded
stone aggregate 20 mm nominal size) upto plinth level with :
7.1.1 Cement mortar 1:6 (1 cement : 6 coarse sand) Cum - 6,653.45 -
5.02 7.2 Random rubble masonry with hard stone in superstructure above plinth level
and upto floor five level, including leveling up with cement concrete 1:6:12 (1
cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) at
sindow sills, ceiling level and the like.
7.2.1 Cement mortar 1:6 (1 cement : 6 coarse sand) Cum - 8,275.70 -
Total of sub-head (5.0) -
6.0 8 Cladding Work -
6.01 8.2 Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and
prepolished, machine cut for kitchen platforms, vanity counters, window sills,
facias and similar locations of required size, approved shade, colour and texture
laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints -
treated with white cement, mixed with matching pigment, epoxy touch ups,
including rubbing, curing, moulding and polishing to edges to give high gloss finish
etc. complete at all levels.
8.2.2 Granite of any colour and shade -
S. No. Description Unit Quantity Rate Amount (In Rs)
6.02 8.4 Extra for fixing marble /granite stone, over and above corresponding basic item, in
facia and drops of width upto 150 mm with epoxy resin based adhesive, including Metre 221.00 475.55 1,05,096.55
cleaning etc. complete.
6.03 8.5 Extra for providing opening of required size & shape for wash basin/ kitchen sink
in kitchen platform, vanity counter and similar location in marble/ Granite/ stone
work, including necessary holes for pillar taps etc. including moulding, rubbing and
polishing of cut edges etc. complete.
6.04 8.31 Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622
(thickness to be specified by the manufacturer), of approved make, in all colours,
shades except burgundy, bottle green, black of any size as approved by Engineer-in-
Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement Sqm 3,568.00 1,063.45 37,94,389.60
mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg
per sqm, including pointing in white cement mixed with pigment of matching shade
Total of sub-head (6.0) 50,50,232.51
7.0 9 Wood Work & PVC Work -
7.01 9.12 Extra for providing frosted glass panes 4 mm thick instead of ordinary float glass
panes 4 mm thick in doors, windows and clerestory window shutters. (Area of
opening for glass panes excluding portion inside rebate shall be measured).
7.02 9.21 Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I)
non-decorative type, core of block board construction with frame of 1st class hard
wood and well matched commercial 3 ply veneering with vertical grains or cross -
bands and face veneers on both faces of shutters:
9.21.1 35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws
7.03 9.23 Extra for providing lipping with 2nd class teak wood battens 25 mm minimum
depth on all edges of flush door shutters (over all area of door shutter to be Sqm 497.00 401.40 1,99,495.80
7.04 9.26 Extra for cutting rebate in flush door shutters (Total area of the shutter to be
7.05 9.47 Providing and fixing nickel plated M.S. pipe curtain rods with nickel plated
7.06 9.48 Providing and fixing M.S. grills of required pattern in frames of windows etc. with
M.S. flats, square or round bars etc. including priming coat with approved steel -
primer all complete
9.48.1 Fixed to steel windows by welding kg 17,398.00 181.00 31,49,038.00
7.07 9.24 Extra for providing vision panel not exceeding 0.1 sqm in all type of flush doors
(cost of glass excluded) (overall area of door shutter to be measured):
9.24.1 Rectangular or square Sqm 286.00 173.95 49,749.70
7.08 9.55 Deduction for not providing and fixing ISI marked M.S. pressed butt hinges bright
finished with necessary screws etc. complete :
7.09 9.96 Providing and fixing aluminium sliding door bolts, ISI marked anodised (anodic
coating not less than grade AC 10 as per IS : 1868), transparent or dyed to required -
colour or shade, with nuts and screws etc. complete :
7.10 9.68 Providing and fixing oxidised M.S. casement stays (straight peg type) with
necessary screws etc. complete.
9.68.1 300 mm weighing not less than 200 gms Each 59.25 -
7.11 9.84 Providing and fixing aluminium extruded section body tubular type universal
hydraulic door closer (having brand logo with ISI, IS : 3564, embossed on the
body, door weight upto 36 kg to 80 kg and door width from 701 mm to 1000 mm), Each 59.00 856.30 50,521.70
with double speed adjustment with necessary accessories and screws etc. complete.
7.12 9.85 Providing and fixing bright finished brass casement window fastener with
necessary screws etc. complete.
7.13 9.97 Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating
not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour -
or shade, with necessary screws etc. complete :
S. No. Description Unit Quantity Rate Amount (In Rs)
7.14 9.100 Providing and fixing aluminium handles, ISI marked, anodised (anodic coating not
less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or -
shade, with necessary screws etc. complete :
7.15 9.101 Providing and fixing aluminium hanging floor door stopper, ISI marked, anodised
(anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to
required colour and shade, with necessary screws etc. complete.
9.101.2 Twin rubber stopper Each 305.00 62.25 18,986.25
7.16 9.154 Providing and fixing frame work for partitions/ wall lining etc. made of 50x50x1.6
mm hollow MS tube, placed along the walls, ceiling and floor in a grid pattern with
spacing @ 60 cm centre to centre both ways (vertically & horizontally) or at
required spacing near opening, with necessary welding at junctions and fixing the
frame to wall/ ceiling/ floors with steel dash fasteners of 8 mm dia, 75 mm long Kg 2,036.00 133.35 2,71,500.60
bolt, including making provision for opening for doors, windows, electrical
conduits, switch boards etc., including providing with two coats of approved steel
primer etc. complete, all as per direction of Engineer-in-charge.
Total of sub-head (7.0) 53,71,669.25
8.0 10 Steel Work -
10.2 Structural steel work riveted, bolted or welded in built up sections, trusses and
framed work, including cutting, hoisting, fixing in position and applying a priming 7,957.00 111.95 8,90,786.15
coat of approved steel primer all complete.
8.01 10.3 Providing and fixing in position collapsible steel shutters with vertical channels
20x10x2 mm and braced with flat iron diagonals 20x5 mm size, with top and
bottom rail of T-iron 40x40x6 mm, with 40 mm dia steel pulleys, complete with Sqm 94.00 9,397.35 8,83,350.90
bolts, nuts, locking arrangement, stoppers, handles, including applying a priming
coat of approved steel primer.
10.5 Providing and fixing 1mm thick M.S. sheet door with frame of
40x40x6 mm angle iron and 3 mm M.S. gusset plates at the
junctions and corners, all necessary fittings complete, including
applying a priming coat of approved steel primer.
10.5.2 Using flats 30x6mm for diagonal braces and central cross piece
8.02 10.6 Supplying and fixing rolling shutters of approved make, made of required size M.S.
laths, interlocked together through their entire length and jointed together at the end
by end locks, mounted on specially designed pipe shaft with brackets, side guides
and arrangements for inside and outside locking with push and pull operation
complete, including the cost of providing and fixing necessary 27.5 cm long wire
springs manufactured from high tensile steel wire of adequate strength conforming
to IS: 4454 - part 1 and M.S. top cover of required thickness for rolling shutters.
10.6.1 80x1.25 mm M.S. laths with 1.25 mm thick top cover Sqm 27.00 3,008.80 81,237.60
8.03 10.7 Providing and fixing ball bearing for rolling shutters. Each 3.00 424.20 1,272.60
8.04 10.8 Extra for providing mechanical device chain and crank operation for operating
rolling shutters
10.8.1 Exceeding 10.00 sqm and upto 16.80 sqm in the area Sqm 15.00 1,108.70 16,630.50
8.05 10.11.2(M) Providing and fixing factory made M.S. Tubular shutter for doors, windows and
ventilators side /top /centre hung, with Z / T and like tubular profile of required
size, made of 1.60mm thick M.S. sheet, joints mitred and flash butt welded,
including providing and fixing 95mm long ball type hinges of diameter 16mm,
including priming coat of approved steel primer, but excluding the cost of other
fittings, all complete as per approved design (sectional weight of only M.S. tubular
profile shall be measured for payment).
8.06 10.12 Providing and fixing steel beading of size 10 x 10 x 1.6 mm (box type), approved
(Modified) shape and section with screws in steel doors, windows, ventilators, composite units Metre 1,155.00 45.42 52,460.10
and M.S. tubular frame erc.
8.07 10.13 Providing and fixing T-iron frames for doors of mild steel Tee-sections, joints
mitred and welded, including fixing of necessary butt hinges and screws and -
applying a priming coat of approved steel primer.
10.13.1 Fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block
15x10x10 cm of C.C. 1:3:6 (1 Cement : 3 coarse sand : 6 graded stone aggregate 20 kg 10,573.00 114.65 12,12,194.45
mm nominal size).
8.08 10.15 Providing and fixing M.S. Tubular frames for doors, windows, ventilators and
cupboard with rectangular/ L-Type sections, made of 1.60 mm thick M.S.
Sheet, joints mitred, welded and grinded finish, with profiles of required size,
including fixing of necessary butt hinges and screws and applying a
priming coat of approved steel primer.
10.15.1 Fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block
15x10x10 cm of C.C. 1:3:6 (1 Cement : 3 coarse sand : 6 graded stone aggregate 20 kg 27,653.00 146.55 40,52,547.15
mm nominal size).
S. No. Description Unit Quantity Rate Amount (In Rs)
8.09 10.16 Steel work in built up tubular (round, square or rectangular hollow tubes etc.)
trusses etc., including cutting, hoisting, fixing in position and applying a priming
coat of approved steel primer, including welding and bolted with special shaped
washers etc. complete.
10.16.1 Hot finished welded type tubes kg 3,870.00 155.40 6,01,398.00
8.10 10.25 Steel work welded in built up sections/ framed work, including cutting, hoisting,
fixing in position and applying a priming coat of approved steel primer using -
structural steel etc. as required.
10.25.2 In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works
10.25.1 In stringers, treads, landings etc. of stair cases, including
use of chequered plate wherever required, all complete
8.11 10.26 Providing and fixing hand rail of approved size by welding etc. to steel ladder
railing, balcony railing, staircase railing and similar works, including applying -
priming coat of approved steel primer.
8.12 10.28 Providing and fixing stainless steel (Grade 304) railing made of Hollow tubes,
channels, plates etc., including welding, grinding, buffing, polishing and making
curvature (wherever required) and fitting the same with necessary stainless steel
nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless
steel dash fasteners , stainless steel bolts etc., of required size, on the top of the kg 3,727.00 612.25 22,81,855.75
floor or the side of waist slab with suitable arrangement as per approval of
Engineer-incharge, (for payment purpose only weight of stainless steel members
shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.).
8.13 10.29 Providing & fixing fly proof wire gauze to windows, clerestory windows & doors
with M.S. Flat 15x3 mm and nuts & bolts complete.
10.29.2 Stainless steel (grade 304) wire gauze of 0.5 mm dia wire and 1.4 mm aperture on
8.14 10.30 Providing & fixing glass panes with putty and glazing clips in steel doors,
windows, clerestory windows, all complete with :
10.30.1 4.0 mm thick glass panes (weights not less than 10 kg/ sqm) Sqm 1,196.00 940.30 11,24,598.80
10.30.2 5.0 mm thick glass panes (weights not less than 12.50 kg/ sqm) Sqm 149.00 1,243.50 1,85,281.50
Total of sub-head (8.0) 1,48,61,001.58
9.0 11 Flooring -
9.01 11.3 Cement concrete flooring 1:2:4 (1 cement : 2 coarse sand : 4 graded stone
aggregate) finished with a floating coat of neat cement, including cement slurry, but -
excluding the cost of nosing of steps etc. complete.
11.3.1 40 mm thick with 20 mm nominal size stone aggregate Sqm 69.00 545.00 37,605.00
9.03 11.13 Providing and fixing glass strips in joints of terrazo/ cement concrete floors. -
11.13.1 40 mm wide and 4 mm thick Metre 203.00 79.50 16,138.50
9.04 11.23 Marble stone flooring with 18 mm thick marble stone, as per sample of marble
approved by Engineer-in-charge, over 20 mm (average) thick base of cement mortar
1:4 (1 cement : 4 coarse sand) laid and jointed with grey cement slurry, including -
rubbing and polishing complete with :
Note : Qty. shall be executed in marble strips of width upto 50mm.
11.23.5 Udaipur green marble Sqm - 2,100.40 -
9.05 11.26 Kota stone slab flooring over 20 mm (average) thick base laid over and jointed with
grey cement slurry mixed with pigment to match the shade of the slab, including
rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement : 4
9.06 11.27 Kota stone slabs 20 mm thick in risers of steps, skirting, dado and pillars laid on 12
mm (average) thick cement mortar 1:3 (1 cement: 3 coarse sand) and jointed with
grey cement slurry mixed with pigment to match the shade of the slabs, including
rubbing and polishing complete.
9.07 11.31 Extra for pre finished nosing in treads of steps of Kota stone/ sand stone slab. Metre 948.00 157.35 1,49,167.80
9.08 11.40 Providing and laying rectified Glazed Ceramic floor tiles of size 300x300 mm or
more (thickness to be specified by the manufacturer), of 1st quality conforming to
IS : 15622, of approved make, in all colours, shades, except White, Ivory, Grey,
Fume Red Brown, laid on 20 mm thick Cement Mortar 1:4 (1 Cement : 4Coarse Sqm 1,292.00 1,225.10 15,82,829.20
sand), jointing with grey cement slurry @ 3.3 kg/ sqm including pointing the joints
with white cement and matching pigments etc., complete.
S. No. Description Unit Quantity Rate Amount (In Rs)
9.09 11.41 Providing and laying full body (Homogeneous) Vitrified floor tiles in different
sizes (thickness to be specified by the manufacturer) with water absorption less
than 0.08% and conforming to IS: 15622, of approved make, in all colours and
shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing
with grey cement slurry @ 3.3kg/sqm including grouting the joints with white
cement and matching pigments etc., complete.
9.10 11.46 Providing and laying full body (Homogeneous) Vitrified tiles in different sizes
(thickness to be specified by manufacturer), with water absorption less than 0.08 %
and conforming to I.S. 15622, of approved make, in all colours & shade, in skirting,
riser of steps, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse -
sand), jointing with grey cement slurry @ 3.3kg/sqm including grouting the joint
with white cement & matching pigments etc. complete.
9.11 23.7 Supplying, filling, spreading & leveling coarse sand of size range 1.5 mm to 2 mm
in recharge pit, in required thickness over gravel layer, for all leads & lifts, all Cum 6.00 1,309.00 7,854.00
complete as per direction of Engineer -incharge.
9.12 16.89 Providing and laying matt finished vitrified tile of size 300x300x9.8mm having
with water absorption less than 0.5% and conforming to IS: 15622 of approved
make in all colours and shades in for outdoor floors such as footpath, court yard,
multi modals location etc., laid on 20mm thick base of cement mortar 1:4 (1 cement Sqm 383.00 1,250.75 4,79,037.25
: 4 coarse sand) in all shapes & patterns including grouting the joints with white
cement mixed with matching pigments etc. complete as per direction of Engineerin-
9.13 16.90 Providing and laying tactile tile (for vision impaired persons as per standards) of
size 300x300x9.8mm having with water absorption less than 0.5% and conforming
to IS:15622 of approved make in all colours and shades in for outdoor floors such
as footpath, court yard, multi modals location etc., laid on 20mm thick base of Sqm 39.00 1,719.00 67,041.00
cement mortar 1:4 (1 cement : 4 coarse sand) in all shapes & patterns including
grouting the joints with white cement mixed with matching pigments etc. complete
as per direction of Engineer-in-Charge.
Total of sub-head (9.0) 1,97,94,591.05
10.0 12 Roofing -
10.01 12.21 Providing gola 75x75 mm in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4
stone aggregate 10 mm and down gauge), including finishing with cement mortar -
1:3 (1 cement : 3 fine sand) as per standard design :
12.21.1 In 75x75 mm deep chase Metre 20.00 260.20 5,204.00
10.02 12.22 Making khurras 45x45 cm with average minimum thickness of 5 cm cement
concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate of 20 mm
nominal size) over P.V.C. sheet 1 m x1 m x 400 micron, finished with 12 mm Each 107.00 266.60 28,526.20
cement plaster 1:3 (1 cement : 3 coarse sand) and a coat of neat cement, rounding
the edges and making and finishing the outlet complete.
10.03 12.47 Providing & fixing UV stabilised fiberglass reinforced plastic sheet roofing up to
any pitch, including fixing with polymer coated 'J' or 'L' hooks, bolts & nuts 8mm
dia. G.I plain/bitumen washers complete but excluding the cost of purlins, rafters,
trusses etc. The sheets shall be manufactured out of 2400 TEX panel rovigs
incorporating minimum 0.3% ultra-violet stabiliser in resin system under -
approximately 2400 psi and hot cured. They shall be of uniform pigmentation and
thickness without air pockets and shall conform to IS 10192 and IS 12866.The
sheets shall be opaque or translucent, clear or pigmented, textured or smooth as
12.47.2 2 mm thick flat Sqm - 1,048.50 -
10.04 12.50 Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch
of corrugation as approved by Engineer-in-charge) 0.50 mm (+ 0.05 %) total coated
thickness with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel
grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-
18 microns. Sheet should have protective guard film of 25 microns minimum to
avoid scratches during transportation and should be supplied in single length upto Sqm 391.00 671.55 2,62,576.05
12 metre or as desired by Engineer-in-charge. The sheet shall be fixed using self
drilling /self tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto
any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins,
rafters and trusses and including cutting to size and shape wherever required.
10.05 12.51 Providing and fixing precoated galvanised steel sheet roofing accessories 0.50 mm
(+0.05 %) total coated thickness, Zinc coating 120 grams per sqm as per IS: 277, in
240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and -
polyester top coat 15-18 microns
using self drilling/ self tapping screws complete :
12.51.2 Flashings/ Aprons.( Upto 600 mm) Metre 12.00 412.85 4,954.20
12.51.4 Barge board (upto 300 mm) Metre 23.00 384.20 8,836.60
12.51.6 Gutter (600 mm over all girth) Metre 23.00 1,110.60 25,543.80
Total of sub-head (10.0) 3,35,640.85
11.0 13 Finishing -
11.01 13.4 12 mm cement plaster of mix -
S. No. Description Unit Quantity Rate Amount (In Rs)
11.02 13.5 15 mm cement plaster on rough side of single or half brick wall of mix: -
11.03 13.16 6 mm cement plaster of mix -
11.04 13.18 Neat cement punning Sqm 140.00 67.80 9,492.00
11.05 13.11 18 mm cement plaster in two coats under layer 12 mm thick cement plaster 1:5 (1
cement : 5 coarse sand) finished with a top layer 6 mm thick cement plaster 1:6 (1 Sqm 10,981.00 442.75 48,61,837.75
cement : 6 fine sand)
11.06 13.21 Extra for providing and mixing water proofing material in cement plaster work in per bag of 50kg
proportion recommended by the manufacturers. cement used in 190.00 18.50 3,515.00
11.07 13.26 Providing and applying plaster of paris putty of 2 mm thickness over plastered
surface to prepare the surface even and smooth complete.
11.08 13.27 (M) Extra for lining out plaster to imitate stone or concrete blocks or brick walling.
11.09 13.37 White washing with lime to give an even shade : -
13.37.1 New work (three or more coats) Sqm 360.00 32.45 11,682.00
11.10 13.41 Distempering wath 'lst quality acrylic distemper (ready mixed) having VOC content
less than 50 gram/litre, of approved manufacturer, of required shade and colour all
13.41.1 New work (two or more coats) over and including water thinnable priming coat
with cement primer having VOC content less than 50 qram/litre
11.11 13.47 Finishing walls with Premium Acrylic Smooth exterior paint with Silicone
additives of required shade:
13.47.1 New work (Two or more coats applied @ 1.43 ltr/10 sqm over and including
priming coat of exterior primer applied @ 0.90 kg/10 sqm)
11.12 13.50 Applying priming coat: -
13.50.3 With ready mixed red oxide zinc chromate primer of approved brand and
manufacture on steel galvanised iron/ steel works
11.14 13.61 Painting with synthetic enamel paint of approved brand and manufacture to give an
13.61.1 Two or more coats on new work Sqm 4,397.00 131.45 5,77,985.65
11.15 13.80 Providing and applying white cement based putty of average thickness 1 mm, of
approved brand and manufacturer, over the plastered wall surface to prepare the Sqm 1,625.00 123.85 2,01,256.25
surface even and smooth complete.
Total of sub-head (11.0) 2,58,68,815.63
12.0 21 Aluminium Work -
12.01 21.1 Providing and fixing aluminium work for doors, windows, ventilators and partitions
with extruded built up standard tubular sections/appropriate Z sections and other
sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash
fasteners of required dia and size, including necessary filling up the gaps at
junctions, i.e. at top, bottom and sides with required EPDM rubber/neoprene gasket
etc. Aluminium sections shall be smooth, rust free,straight, mitred and jointed
mechanically wherever required including cleat angle, Aluminium snap beading for -
glazing / paneling, C.P. brass / stainless steel screws, all complete as per
architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling
and dash fasteners to be paid for separately) :
21.1.1 For Fixed Portion -
21.1.1.2 Powder coated aluminium (minimum thickness of powder coating 50 micron) kg 270.00 466.30 1,25,901.00
12.02 21.1.2 For shutters of doors, windows & ventilators including providing and fixing hinges/
pivots and making provision for fixing of fittings wherever required including the
cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for
21.1.2.2 Powder coated aluminium (minimum thickness of powder coating 50 micron) kg 308.00 553.55 1,70,493.40
12.03 21.3 Providing and fixing glazing in aluminium door, window, ventilator shutters and
partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the
architectural drawings and the directions of Engineer-in-charge . (Cost of
aluminium snap beading shall be paid in basic item):
21.3.1 With float glass panes of 4.00 mm thickness Sqm - 1,019.80 -
21.3.2 With float glass panes of 5 mm thickness (weight not
less than 12.50 kg/ sqm)
21.3.3 With float glass panes of 8 mm thickness (weight not
less than 20 kg/ sqm)
S. No. Description Unit Quantity Rate Amount (In Rs)
12.04 21.4 Providing and fixing double action hydraulic floor spring of approved brand and
manufacture conforming to IS : 6315, having brand logo embossed on the body /
plate with double spring mechanism and door weight upto 125 kg, for doors,
including cost of cutting floors, embedding in floors as required and making good -
the same matching to the existing floor finishing and cover plates with brass pivot
and single piece M.S. sheet outer box with slide plate etc. complete as per the
direction of Engineer-in-charge.
21.4.1 With stainless steel cover plate minimum 1.25 mm
12.05 21.13 Providing and fixing Brass 100mm mortice latch and lock with 6 levers without
pair of handles (best make of approved quality) for aluminium doors including Each 5.00 449.55 2,247.75
necessary cutting and making good etc. complete.
21.16 Providing and fixing aluminium round shape handle of outer dia 100 mm with SS
screws etc. complete as per direction of Engineer-incharge
21.16.2 Powder coated minimum thickness 50 micron aluminium Each 20.00 89.60 1,792.00
Total of sub-head (12.0) 3,82,984.15
13.0 22 Water Proofing -
13.01 22.3 Providing and laying water proofing treatment to vertical and horizontal surfaces of
depressed portions of W.C., kitchen and the like consisting of: -
(i) Ist course of applying cement slurry @ 4.4 kg/sqm mixed with water proofing
compound conforming to IS 2645 in recommended proportions including rounding -
off junction of vertical and horizontal surface.
(ii) IInd course of 20 mm cement plaster 1:3 (1 cement : 3 coarse sand) mixed with
water proofing compound in recommended proportion including rounding off -
junction of vertical and horizontal surface.
(iii) IIIrd course of applying blown or residual bitumen applied hot at 1.7 kg. per
(iv) IVth course of 400 micron thick PVC sheet. (Overlaps at joints of PVC sheet
should be 100 mm wide and pasted to each other with bitumen @ 1.7 kg/sqm). Sqm 1,275.00 669.05 8,53,038.75
13.02 22.4 Providing and Placing in position suitable PVC water stops conforming to IS:12200
for construction/ expansion joints between two RCC members and fixed to the
reinforcement with binding wire before pouring concrete etc. complete :
22.4.1 Serrated with central bulb (225 mm wide, 8-11 mm thick) Sqm - 285.60 -
13.03 22.7 Providing and laying integral cement based water proofing treatment including
preparation of surface as required for treatment of roofs, balconies, terraces etc
consisting of following operations: -
a) Applying a slurry coat of neat cement using 2.75 kg/sqm of cement admixed
with water proofing compound conforming to IS. 2645 and approved by Engineer-
in-charge over the RCC slab including adjoining walls upto 300 mm height
including cleaning the surface before treatment.
b) Laying brick bats with mortar using broken bricks/brick bats 25 mm to 115 mm
size with 50% of cement mortar 1:5 (1 cement : 5 coarse sand) admixed with water
proofing compound conforming to IS : 2645 and approved by Engineer-in-charge
over 20 mm thick layer of cement mortar of mix 1:5 (1 cement :5 coarse sand )
admixed with water proofing compound conforming to IS : 2645 and approved by
Engineer-in-charge to required slope and treating similarly the adjoining walls upto
300 mm height including rounding of junctions of walls and slabs.
c) After two days of proper curing applying a second coat of cement slurry using
2.75 kg/ sqm of cement admixed with water proofing compound conforming to IS : -
2645 and approved by Engineerin-charge.
d) Finishing the surface with 20 mm thick jointless cement mortar of mix 1:4 (1
cement :4 coarse sand) admixed with water proofing compound conforming to IS :
2645 and approved by Engineerin-charge including laying glass fibre cloth of
approved quality in top layer of plaster and finally finishing the surface with trowel
with neat cement slurry and making pattern of 300x300 mm square 3 mm deep.
e) The whole terrace so finished shall be flooded with water for a minimum period
of two weeks for curing and for final test.“All above operations to be done in order -
and as directed and specified by the Engineer-in-Charge :
22.7.1 With average thickness of 120 mm and minimum thickness at khurra as 65 mm.
S. No. Description Unit Quantity Rate Amount (In Rs)
13.04 22.23 Providing and applying integral crystalline slurry of hydrophilic in nature for
waterproofing treatment to the RCC structures like retaining walls of the basement,
water tanks, roof slabs, podiums, reservior, sewage & water treatment plant,
tunnels / subway and bridge deck etc., prepared by mixing in the ratio of 5 : 2 (5
parts integral crystalline slurry : 2 parts water) for vertical surfaces and 3 : 1 (3
parts integral crystalline slurry : 1 part water) for horizontal surfaces and applying
the same from negative (internal) side with the help of synthetic fiber brush. The
material shall meet the requirements as specified in ACI-212-3R-2010 i.e by - -
reducing permeability of concrete by more than 90% compared with control
concrete as per DIN 1048 and resistant to 16 bar hydrostatic pressure on negative
side. The crystalline slurry shall be capable of self-healing of cracks up to a width
of 0.50mm. The work shall be carried out all complete as per specification and the
direction of the engineer-in-charge. The product performance shall carry guarantee
for 10 years against any leakage.
22.23.1 For vertical surface two coats @ 0.70 kg per sqm Sqm 709.00 406.25 2,88,031.25
22.23.2 For horizontal surface one coat @1.10 kg per sqm. Sqm 352.00 311.50 1,09,648.00
Total of sub-head (13.0) 79,49,366.15
14.0 16 Road Work -
14.01 16.1 Preparation and consolidation of sub grade with power road roller of 8 to 12 tonne
capacity after excavating earth to an average of 22.5 cm depth, dressing to camber
and consolidating with road roller including making good the undulations etc. and Sqm 10,641.00 180.50 19,20,700.50
re-rolling the sub grade and disposal of surplus earth with all lead and lift.
14.04 16.11 Dry stone pitching 22.5 cm thick including supply of stones and preparing surface
16.43.2 (M) Making provision for contraction/ expansion, construction & longitudinal joints of
sixe 10 mm wide x 50 mm deep by groove cutting machine. As per direction of Cum 279.00 141.80 39,562.20
Engineer-in-charge.
16.46 Providing and filling in position rubberized bitumen hot sealing compound for
sealing of expansion joints in roads / pavements all complete as per direction of the
Engineer-in-Charge.
16.46.1 Using grade 'A' sealing compound conforming to IS: 1834. Sqm 2,583.00 7.50 19,372.50
14.05 16.11 Deduct for using available stone of size 15 cm x 22.5 cm for dry stone pitching.
(Modified) (Rate is below relevant item)
14.06 16.53 Providing and fixing concertina coil fencing with punched tape concertina coil 600
mm dia 10 metre openable length (total length 90 m), having 50 nos rounds per 6
metre length, upto 3 m height of wall with existing angle iron 'Y' shaped placed
2.4m or 3.00 m apart and with 9 horizontal R.B.T. reinforced barbed wire, stud tied
with G.I. staples and G.I. clips to retain horizontal, including necessary bolts or
G.I. barbed wire tied to angle iron, all complete as per direction of Engineerin- Metre 982.00 303.65 2,98,184.30
charge, with reinforced barbed tape(R.B.T.) / Spring core (2.5mm thick) wire of
high tensile strength of 165 kg/ sq.mm with tape (0.52 mm thick) and weight
43.478 gm/ metre (cost of M.S. angle, C.C. blocks shall be paid separately)
14.07 16.19 Supplying at site Angle iron post & strut of required size including bottom to be
split and bent at right angle in opposite direction for 10 cm length and drilling holes kg 2,979.00 99.95 2,97,751.05
upto 10 mm dia. etc. complete.
14.08 16.62 Providing and applying 2.5 mm thick road marking strips (retro- reflective) of
specified shade/ colour using hot thermoplastic material by fully/ semi automatic
thermoplastic paint applicator machine fitted with profile shoe, glass beads
dispenser, propane tank heater and profile shoe heater, driven by experienced
operator on road surface including cost of material, labour, T&P, cleaning the road
surface of all dirt, seals, oil, grease and foreign material etc. complete as per
direction of Engineer-in-charge and accordance with applicable specifications.
14.10 16.68 Providing and laying 60mm thick factory made cement concrete interlocking paver
block of M-30 grade made by block making machine with strong vibratory
compaction, of approved size, design & shape, laid in required colour and pattern
over and including 50mm thick compacted bed of coarse sand, filling the joints
with line sand etc. all complete as per the direction of Engineer-in-charge.
S. No. Description Unit Quantity Rate Amount (In Rs)
14.11 16.69 Providing and laying at or near ground level factory made kerb stone of M-25 grade
cement concrete in position to the required line, level and curvature, jointed with
cement mortar 1:3 (1 cement: 3 coarse sand), including making joints with or
without grooves (thickness of joints except at sharp curve shall not to more than
5mm), including making drainage opening wherever required complete etc. as per Cum 63.00 8,613.55 5,42,653.65
direction of Engineer-in-charge (length of finished kerb edging shall be measured
for payment). (Precast C.C. kerb stone shall be approved by Engineer-in-charge).
14.12 16.75 Providing and laying C.C. pavement of mix M-25 with ready mixed concrete from
batching plant. The ready mixed concrete shall be laid and finished with screed
board vibrator , vacuum dewatering process and finally finished by floating,
brooming with wire brush etc. complete as per specifications and directions of
Engineer-in-charge. (The panel shuttering work shall be paid for separately). (Note:-
Cement content considered in this item is @ 330 kg/cum. Excess/less cement used
as per design mix is payable/ recoverable separately).
14.13 16.76 Deduct for using of M-20 grade concrete instead of M-25 grade concrete in C.C.
14.14 16.3 Supplying and stacking at site. -
16.3.2 63 mm to 45 mm size stone aggregate Cum 272.00 1,624.50 4,41,864.00
14.15 16.3.3 53 mm to 22.4 mm size stone aggregate Cum 272.00 1,837.25 4,99,732.00
14.18 16.4 Laying, spreading and compacting stone aggregate of specified sizes to WBM
specifications in uniform thickness, hand picking, rolling with 3 wheeled
road/vibratory roller 8-10 tonne capacity in stages to proper grade and camber,
applying and brooming requisite type of screening / binding material to fill up
interstices of coarse aggregate, watering and compacting to the required density .
Total of sub-head (14.0) 1,02,88,076.08
15.00 Non-Schedule Items - Civil -
15.01 MR 1 Providing signage viz display/name plate and like of required size made out of 20
gauge thick stainless steel (304 garde) including engraved subject matter, message
(Hindi/English and / or bi-lingual), symbols, borders and logo etc. The engraved
letter, borders etc. to be finished with paint etc. of required colour scheme and the
plate to be fixed to wooden/wall surface with 25mm long stainless steel spacer/stud Sq. inch 3,750.00 23.18 86,925.00
all complete as per direction of Engineer-in-charge.
15.02 MR 2 Graffiti painting on wall as approved logo of Eklavya (EMRS) by high gloss Sqm 48
acrylic colour before making logo, prepare the surface clean, fill POP in voids,
apply 1mm white birla putty and primer including material, labour and T&P etc.
all complete under instruction of Engineer-in-charge.
15.02 MR 3 Providing and fixing factory made prelaminated flush door comprises core of block
board construction with frame of 1st class hard wood and well matched commercial
3 ply veneering with vertical grains or cross bands and face veneers on both faces
of shutters conforming to IS: 2202 (part 1) followed with machine pressed 1.00mm
thick lamination on both faces of shutter in required finish and shade with suitable
adhesive including providing and fixing 3 to 5 mm thick teak lipping along edges of Sqm 515.00 5,310.00 27,34,650.00
shutter all complete as per direction of Engineer-in- charge.
a) 35 mm thick including ISI marked Stainless Steel butt hinges (heavy weight)
100mm x 60mm x 2.5mm with necessary screws.
15.03 MR 4 Providing & fixing G.I. chicken wire mesh of nominal size upto 20mm having 24
gauge thick with G.I. nails etc. to wall surface of dissmilar material viz RCC and Sqm 640.00 211.24 1,35,193.60
brick work etc.all complete.
MR 6 Providing and fixing oxidised M.S. casement window fastener with necessary
screws etc. complete. (copper oxidized as per IS: 1378) each 2,596.00 35.29 91,612.84
a) 100 mm weighing not less than 100 gms
MR 7 Supplying, making & fixing of Eklavya Archery logo made of 18mm thick WPC
BOARD as per image on front wall of school building left & right side inclding all
fixtures and two coats of painting etc all complete as per the direction of Engineer
in charge. a) of outer dimension 5.5 mtr height & 3.5 mtr width
MR 8 Supplying, making & fixing of Eklavya Archery logo made of 18mm thick WPC
BOARD as per image on front wall of main gate inclding all fixtures and two
coats of painting etc all complete as per the direction of Engineer in charge. a) of set 1.00 25,654.46 25,654.46
outer dimension 3 m height & 1.5 m width
S. No. Description Unit Quantity Rate Amount (In Rs)
TOTAL AMOUNT 31,94,286.40
TOTAL AMOUNT 31,94,286.40
16.0 Sanitary Installation (As per D.S.R.) -
16.01 8.10 Providing & fixing stone slab table rubbed, edges rounded and polished of size 75
X 50 cm deep and 1.8 cm thick fixed in urinal patitions by cutting a chase of
appropriate width with chase cutter and embedding the stone in chase with epoxy
grout or with cement concrete 1:2:4 ( 1 cement : 2 coarse sand : 4 graded stone
aggregste 6mm nominal size) as per Engineer-in-charge and finished smooth
8.10.2 Granite Stone of approved shade sqm 7.88 3,542.85 27,917.66
16.02 17.10 Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS: 13983
with CI brackets and stainless steel waste with plug 40mm including painting of
fittings and brackets, cutting and making good the walls wherever required.
17.10.2 Sink without drain board - -
16.03 17.11 Providing and fixing white vitreous china laboratory sink with C.I. brackets, C.P.
brass chain with rubber plug, 40 mm C.P brass waste and 40mm C.P. brass trap
with necessary C.P. brass unions complete, including painting of fittings and
brackets, cutting and making good the wall wherever required :
16.04 17.2 Providing and fixing white vitreous china pedestal type water closet (European type
W.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern,
including flush pipe, with manually controlled device (handle lever), conforming to -
IS : 7231, with all fittings and fixtures complete, including cutting and making
good the walls and floors wherever required :
17.2.1 W.C. pan with ISI marked white solid plastic seat and lid Each 57.00 5,540.55 3,15,811.35
16.05 17.16A Providing and fixing 8 mm dia C.P./S.S. Jet with flexible tube upto 1 metre long
with S.S. triangular plate to Eureopean type W.C. of quality and make as approved Each 57.00 299.35 17,062.95
by Engineer - in-charge
16.06 17.5.1 Providing and fixing single white vitreous china flat back half stall urinal of size
580x380x350 mm with spreaders, unions, waste fitting and other couplings (all in
C.P. brass) including making good the walls wherever required.
16.07 17.72 Providing & fixing PTMT towel ring trapezoidal shape 215 mm long 200 mm wide
with minimum distance of 37 mm from wall face with concealed fittings Each 75.00 204.70 15,352.50
arrangement of approved quality and colour weighing not less than 88 gms
16.08 18.49 Providing and fixing C.P. brass bib cock of approved quality conforming
16.09 18.50 Providing and fixing C.P. brass long nose bib cock of approved quality
conforming to IS standards and weighing not less than 810 gms.
16.10 18.54 Providing and fixing PTMT bib cock of approved quality and colour. - -
18.54.1 15mm nominal bore, 86 mm long, weighing not less than 88 gms Each - 109.85 -
18.54.3 15 mm nominal bore, 165 mm long, weighing not less than 110 gms Each - 156.65 -
16.11 18.52 Providing and fixing C.P. brass stop cock (concealed) of standard design and of
approved make conforming to IS:8931.
18.52.1 15 mm nominal bore (For Shower) Each 136.00 594.75 80,886.00
16.12 18.53 Providing and fixing C.P. brass angle valve for basin mixer and points of approved
quality conforming to IS:8931
18.53.1 15 mm nominal bore (For Shower) Each 446.00 500.35 2,23,156.10
16.13 18.63 Providing and fixing PTMT angle stop cock 15 mm nominal bore, weighing not
less than 85 gms
16.14 17.7 Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps,
32 mm C.P. brass waste of standard pattern, including painting of fittings and
brackets, cutting and making good the walls wherever require:
17.7.4 White Vitreous China Flat back wash basin size 550x
400 mm with single 15 mm C.P. brass pillar tap
16.15 17.7B Providing and fixing wash basin with C.I. brackets, 15 mm PTMT pillar cock, 32
mm PTMT waste coupling of standard pattern, including painting of fittings and
brackets, cutting and making good the walls wherever required. White Vitreous Each - 1,404.00 -
China Flat back wash basin size 550x400 mm with single 15 mm PTMT pillar cock
S. No. Description Unit Quantity Rate Amount (In Rs)
16.16 17.28 Providing & fixing PVC waste pipe for sink including PVC waste fitting Complete
17.28.2 Flexible Pipe - -
16.17 17.34 Providing and fixing toilet paper holder : - -
16.18 18.21 Providing and fixing uplasticised PVC connection pipe with brass unions - -
16.19 17.1 Providing and fixing water closet squatting pan (Indian type W.C. pan ) with 100
mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern,
including flush pipe, with manually controlled device (handle lever) IS : 7231, with - -
all fittings and fixtures complete, including cutting and making good the walls and
floors wherever required:
17.1.1 White Vitreous china Orissa pattern W.C. pan of size 580 x 440 mm with integral
type foot rests
16.20 18.65 Providing and fixing PTMT soap Dish Holder having length of 138mm, breadth
102mm, height of 75mm with concealed fitting arrangements, weighing not less Each 329.00 96.75 31,830.75
16.21 17.71 Providing and fixing PTMT liquid soap container 109 mm wide, 125 mm high and
112 mm distance from wall of standard shape with bracket of the same materials
with snap fittings of approved quality and colour, weighing not less than 105 gms.
16.22 17.73 Providing and fixing PTMT towel rail complete with brackets fixed to wooden
cleats with CP brass screws with concealed fittings arrangement of approved - -
quality and colour.
17.73.2 600 mm long towel rail with total length of 645 mm, width 78 mm and effective
height of 88 mm, weighing not less than 190 gms.
16.23 18.64 Providing and fixing PTMT swivelling shower, 15 mm nominal bore, weighing not
less than 40 gms
17.69 Providing and fixing PTMT Waste Coupling for wash basin and sink, of approved
quality and colour.
17.69.1 Waste coupling 31 mm dia of 79 mm length and 62mm breadth weighing not less
18.56 Providing and fixing PTMT pillar cock of approved quality and colour. Each - -
18.56.1 15 mm nominal bore, 107 mm long, weighing not less than 110 gms Each - 180.80 -
Sanitary Installations work (Non-Scheduled Items) -
16.24 MR 09 Providing and fixing U-shaped stainless steel grab bar (for differntly abled person)
of size 600mm wall mounted, movable (horizontally and vertically) with necessary
dash fastener etc. all complete. (Basic rate of material shall not be less than
16.25 MR 10 Providing and fixing white vitreous china oval shape wash basin (counter top) of
size 560x400mm with C.I. brackets/rag bolt of required size, 32 mm C. P. brass
waste coupling of standard pattern, including painting of fittings and brackets, Each 30.00 5,833.63 1,75,008.90
cutting and making good the walls wherever require complete as per direction of
Engineer in Charge
16.26 MR 11 Providing and fixing 600 x 450 mm beveled edge mirror of superior glass (of
approved quality) fixed with stainless steel studs, complete with cutting, making Each 185.00 895.10 1,65,593.50
holes, studs, all fittings, screws, washers and making good the walls.
16.27 MR 12 Providing & fixing stainless steel robe plate/pegs (hook) having three pegs (hook)
in one strip (weight shall not be less than 120 grams) of superior quality with Each 246.00 296.05 72,828.30
necessary scres etc. complete.
16.28 MR 13 Providing and fixing C.P. brass swan neck foam flow pillar cock of approved
quality and conforming to IS standards. a) 15mm nominal bore
16.29 MR 14 Providing and fixing C.P. brass long body nozzle bib cock (two way) of approved
quality conforming to IS standards and weighing not less than 810 gms.
a) 15 mm nominal bore Each 29.00 678.03 19,662.87
MR 15 Providing & fixing stainless steel butterfly robe pegs (hook) having three hooks of
superior quality with necessary scres etc. complete.
Total of sub-head (16.0) (DSR) 23,03,772.06
Total of sub-head (16.0) (Non DSR) 5,19,027.33
17.0 Internal Drainage Installations (As per D.S.R.)
S. No. Description Unit Quantity Rate Amount (In Rs)
17.01 18.58 Providing and fixing PTMT grating of approved quality and colour -
18.58.1 Circular type -
18.58.1.2 125 mm nominal dia with 25mm waste hole. Each 285.00 45.25 12,896.25
17.02 12.41 Providing & fixing on wall face unplasticised -Rigid PVC rain water pipes
conforming to IS:13592 Type A included jointing with seal ring conforning to -
IS:5382 leaving 10 mm gap for thermal expansion. (i)Single socketed pipes.
17.03 12.42. Providing, fixing on wall face unplasticised - PVC moulded fittings /accessories for
unplasticised - Rigid PVC rain water pipes conforming to IS ; 13592 Type A
including jointing with seal ring conforming to IS ; 5382 leaving 10 mm gap for
thermal expansion.
12.42.1.2 Coupler -110 mm diameter Each 174.00 119.95 20,871.30
12.43 Providing and fixing unplasticised -PVC pipe clips of approved design to
unplasticised - PVC rain water pipes by means of 50x50x50 mm hard wood plugs,
screwed with M.S. screws of required length, including cutting brick work and -
fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall
17.04 MR 17 Providing, fixing, jointing and testing in position of ISI marked UV stabilized
uPVC pipes for soil, waste, and vent, Type-B as per IS : 13592 suitable for rubber
ring joints, including all neccessary specials and fittings (confirming to IS:14735)
i.e. bends, tees, junctions (with or without doors), reducers, WC connectors,
couplers, expansion joints / bellows, cowels, clamps, rubber rings, clean outs etc.
fixing at wall/ ceiling/ floor level supported by clamp & hangers etc. in concealed /
inside duct / under floor & basement ceiling / external work etc. including chase
cutting as required, excavation and back filling in all kind of soils, suspended from
floor under false ceiling or embedding the pipes laid under floors / building in 75
mm. alround 1:2:4 cement concrete (1 cement : 2 coarse sand : 4 graded stone
aggregate 20 mm nominal size) including cost of shuttering for proper completion
of the work, breaking and making good the walls and floors etc. after pipes have
been duly laid and tested. The rubber ring shall confirm to IS:5382. The Pipes will
be supported with threaded G I rods & U clamps with nuts, washers etc on
50x50x5 mm slotted angle. The cost will include all support arrangements. The
work includes commissioning of all pipes lines as per drawings and specifications
and as directed by engg-in-charge at site.
a) 110 mm dia (Wall Thickness - 3.2 to 3.8 mm) Metre 2,254.00 564.71 12,72,856.34
75 mm dia (Wall Thickness - 3.2 to 3.8 mm) 438.29 -
17.05 MR 18 Providing and fixing uPVC floor trap of self cleaning design including jointing
with solvent and embedding in cement concrete all complete.
a) 110 mm inlet & 110 mm outlet Each 211.00 237.05 50,017.55
17.06 MR 19 Providing and fixing uPVC inlet fitting (Hopper) maximum with 2 or 3 inlets of 40
to 63 mm OD size fabricated from 110 OD uPVC pipe fixed to uPVC trap jointing
with solvent cement joint and set in a cement concrete 1:2:4 mix complete Each 195.00 352.42 68,721.90
including cost of cutting and making good the walls and floors wherever required.
17.07 MR 20 Providing and fixing uPVC floor drain with uPVC reducing elbow including all
fitting and accessories fixed in cement mortar complete in all respect.
17.08 MR 21 Providing and fixing of uPVC Waste pipes 6 kg/cm2 (IS: 4985:2000) including
with all fittings e.g. couplings, tees, bends, reducers and screwed adoptors jointing
with solvent cement as per Manufacturer's specifications complete including cutting
holes or chases in wall and making good the same wherever required. (Waste pipe
from fixtures).
17.09 MR 22 Providing and fixing uPVC cleanout plug conforming to IS:14735 – 1999 complete
with all fitting, accessories etc. complete.
Total of sub-head (17.0) (DSR) 4,41,120.30
Total of sub-head (17.0) (Non DSR) 15,01,167.47
18.0 Water Supply Installations (As per D.S.R.)
18.01 18.7 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes having thermal
stability for hot and cold water supply including all CPVC plain and brass threaded
fittings including fixing the pipe with clamps at 1.00 m spacing. this includes
jointing of pipes and fittings with one step CPVC solvent cement and testing of
joints complete as per direction of engineer in charge.
Internal work -Exposed on Wall -
18.7.2 20 mm nominal dia pipes Metre 510.00 325.10 1,65,801.00
18.7.3 25 mm nominal dia pipes Metre 430.00 408.55 1,75,676.50
18.7.4 32 mm nominal dia pipes Metre 415.00 500.95 2,07,894.25
S. No. Description Unit Quantity Rate Amount (In Rs)
18.7.5 40 mm nominal dia pipes Metre 120.00 674.35 80,922.00
18.7.6 50 mm nominal dia pipes Metre 927.00 -
18.02 18.8 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes having the
thermal stability for hot and cold water supply including all CPVC plain and brass
threaded fittings including fixing the pipe with clamps at 1.00 m spacing. this
includes jointing of pipes and fittings with one step CPVC solvent cement and the
cost of cutting chases and making good the wall same including testing of joints
complete as per the direction of engineer incharge
Concealed work including cutting chases and making good the wall etc. -
18.8.1 15 mm nominal dia pipes Metre 725.00 439.80 3,18,855.00
18.8.2 20 mm nominal dia pipes Metre 550.00 512.40 2,81,820.00
18.8.3 25 mm nominal dia pipes Metre 310.00 624.70 1,93,657.00
18.8.4 32 mm nominal dia pipes Metre 25.00 711.40 17,785.00
18.03 18.10 Providing and fixing G.I. pipes complete with GI fittings and clamps including
cutting and making good the walls etc. (internal work)
Internal work - Exposed on wall -
18.10.2 20 mm dia, nominal bore Metre 30.00 373.35 11,200.50
18.10.3 25 mm dia, nominal bore Metre 150.00 491.20 73,680.00
18.10.4 32 mm dia, nominal bore Metre 195.00 563.55 1,09,892.25
18.10.5 40 mm dia, nominal bore Metre 10.00 725.15 7,251.50
18.10.6 50 mm dia, nominal bore Metre 10.00 893.20 8,932.00
18.04 18.38 Painting with synPainting G.I. pipes and fittings with synthetic enamel white paint
with two coats over a ready mixed priming coat, both of approved
quality for new work
18.38.2 20 mm dia, nominal bore Metre 30.00 19.65 589.50
18.38.3 25 mm dia, nominal bore Metre 150.00 25.60 3,840.00
18.38.4 32 mm dia, nominal bore Metre 195.00 30.70 5,986.50
18.38.5 40 mm dia, nominal bore Metre 10.00 36.05 360.50
18.38.6 50 mm dia, nominal bore Metre 10.00 43.05 430.50
18.05 18.17 Providing and fixing gun metal gate valve with CI wheel of approved quality
18.17.1 25mm dia, nominal bore Each 12.00 532.35 6,388.20
18.17.2 32 mm dia, nominal bore Each 5.00 589.90 2,949.50
18.17.3 40 mm dia, nominal bore Each 3.00 707.30 2,121.90
18.06 18.19 Providing and fixing gun metal non- return valve of approved quality (screwed end)
18.07 MR 23 Providing and fixing C.P.V.C. ball valve in C.P.V.C. pipe including jointing of
pipes & fittings with one step CPVC solvent cement and testing of joints complete
as per direction of Engineer in Charge. (Astral/Prince/Prakash make or equivalent)
15 mm dia nominal bore Each 10.00 238.63 2,386.30
20 mm dia nominal bore Each 50.00 289.36 14,468.00
25 mm dia nominal bore Each 80.00 395.77 31,661.60
32 mm dia nominal bore Each 60.00 486.33 29,179.80
Total of sub-head (18.0) (DSR) 16,98,528.10
Total of sub-head (18.0) (Non DSR) 77,695.70
19.0 EXTERNAL SEWERAGE SYSTEM -
19.01 2.10 Excavating trenches of required width for pipes, cables, etc including excavation
for sockets, and dressing of sides, by mechanical/manual means ramming of
bottoms, for all depth, including getting out the excavated soil, and then returning
the soil as required, in layers not exceeding 20 cm in depth, including consolidating
each deposited layer by ramming, watering, etc. and disposing of surplus excavated
soil as directed, within a lead of 50 m :
2.10.1 All kinds of soils
2.10.1.2 Pipes, cables etc. exceeding 80 mm dia. but not
exceeding 300 mm dia
19.02 19.1 Providing, laying and jointing glazed stoneware pipes class SP-1 with stiff mixture
of cement mortar in the proportion of 1:1 (1 cement : 1 fine sand) including testing - -
of joints etc. complete :
19.03 19.3 Providing and laying cement concrete 1:5:10 (1 cement : 5 coarse sand : 10 graded
stone aggregate 40 mm nominal size) up to haunches of S.W. pipes including bed - -
concrete as per standard design :
19.04 19.2 Providing and laying cement concrete 1:5:10 (1 cement : 5 coarse sand : 10 graded
stone aggregate 40 mm nominal size) all-round S.W. pipes including bed concrete - -
as per standard design :
19.2.4 250 mm diameter S.W. pipe Metre 85.00 1,476.35 1,25,489.75
S. No. Description Unit Quantity Rate Amount (In Rs)
19.05 19.7 Constructing brick masonry manhole in cement mortar 1:4 ( 1 cement : 4 coarse
sand ) with R.C.C. top slab with 1:1.5:3 mix (1cement : 1.5 coarse sand (zone-III) :
3 graded stone aggregate 20mm nominal size), foundation concrete 1:4:8 mix (1
cement : 4coarse sand (zone-III) : 8 graded stone aggregate 40 mm nominalsize),
inside plastering 12 mm thick with cement mortar 1:3 (1 cement: 3 coarse sand) -
finished with floating coat of neat cement andmaking channels in cement concrete
1:2:4 (1 cement : 2 coarsesand : 4 graded stone aggregate 20 mm nominal size)
finished witha floating coat of neat cement complete as per standard design :
19.7.1 Inside size 90x80 cm and 45 cm deep including C.I. cover with frame (light duty)
455x610 mm internal dimensions, total weight of cover and frame to be not less
than 38 kg (weight of cover 23 kg and weight of frame 15 kg) :
19.7.1.1 With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 each 44.00 11,687.10 5,14,232.40
19.7.2 Inside size 120x90 cm and 90 cm deep including C.I. Cover with frame (medium
duty) 500 mm internal diameter, total weight of cover and frame to be not less than
116 kg (weight of cover 58 kg and weight of frame 58 kg) :
19.7.2.1 With common burnt clay F.P.S. (non modular)
bricks of class designation 7.5
19.06 19.8 Extra for depth for manhole with F.P.S. bricks
19.8.1 Size 90 X 80 cm
19.8.1.1 With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 Metre 2.00 8,127.45 16,254.90
19.8.2.1 With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 Metre 3.00 9,744.25 29,232.75
19.07 19.9 Constructing brick masonry circular type manhole 0.91 m internal dia at bottom
and 0.56m dia at top in cement mortar 1:4 (1 cement : 4 coarse sand), inside cement
plaster 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand) finished
with a floating coat of neat cement, foundation concrete 1:3:6 mix (1 cement : 3
coarse sand : 6 graded stone aggregate 40 mm nominal size), and making necessary -
channel in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone
aggregate 20 mm nominal size) finished with a floating coat of neat cement, all
complete as per standard design :
19.9.1 0.91 m deep with S.F.R.C. cover and frame (heavy duty, HD-20 grade designation)
560 mm internal diameter conforming to I.S. 12592, total weight of cover and
frame to be not less than 182 kg., fixed in cement concrete 1:2:4 (1 cement : 2
coarse sand : 4 graded stone aggregate 20 mm nominal size) including centering, -
shuttering all complete. (Excavation, foot rests and 12mm thick cement plaster at
the external surface shall be paid for separately) :
19.9.1.1 With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 each 4.00 11,705.55 46,822.20
19.08 19.10 Extra depth for circular type manhole 0.91m internal dia (at bottom) beyond 0.91 m
19.10.1 With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 Metre 4.00 6,986.80 27,947.20
19.09 19.11 Constructing brick masonry circular manhole 1.22 m internal dia at bottom and
0.56 m dia at top in cement mortar 1:4 (1 cement :4coarse sand) inside cement
plaster 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand) finished
with a floating coat of neat cement foundation concrete 1:3:6 (1 cement : 3 coarse
sand : 6 graded stone aggregate 40 mm nominal size) and making necessary
channel in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4
graded stone aggregate 20 mm nominal size) finished with a floating coat of neat
cement, all complete as per standard design :
19.11.1 1.68 m deep with SFRC Cover and frame (heavy duty HD- 20 grade designation)
560 mm internal diameter conforming to I.S. 12592, total weight of cover and
frame to be not less than 182 kg. fixed in cement concrete 1:2:4 (1 cement : 2
coarse sand : 4 graded stone aggregate 20 mm nominal size) including centering,
shuttering all complete. (Excavation, foot rests and 12 mm thick cement plaster at
the external surface shall be paid for separately) :
19.11.1.1 With common burnt clay F.P.S. (non modular)
bricks of class designation 7.5
19.10 19.12 Extra depth for circular type manhole 1.22 m internal dia (at bottom) beyond 1.68
19.12.1 With common burnt clay F.P.S. (non modular) bricks of
class designation 7.5
19.11 19.16 Providing orange colour safety foot rest of minimum 6 mm thick plastic
encapsulated as per IS : 10910, on 12 mm dia steel bar conforming to IS : 1786,
having minimum cross section as 23 mmx25 mm and over all minimum length 263
mm and width as 165 mm with minimum 112 mm space between protruded legs
having 2 mm tread on top surface by ribbing or chequering besides necessary and
adequate anchoring projections on tail length on 138 mm as per standard drawing
and suitable to with stand the bend test and chemical resistance test as per each 130.00 469.00 60,970.00
specifications and having manufacture's permanent identification mark to be visible
even after fixing, including fixing in manholes with 30x20x15 cm cement concrete
block 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal
size) complete as per design.
S. No. Description Unit Quantity Rate Amount (In Rs)
19.12 19.19 Providing and fixing in position pre-cast R.C.C. manhole cover and frame of
required shape and approved quality
19.19.4.1 Circular shape 560 mm internal dia each 5.00 1,882.20 9,411.00
19.13 19.4 Providing and fixing square-mouth S.W. gully trap class SP-1complete with C.I.
grating brick masonry chamber with water tight C.I. cover with frame of 300 x300
mm size (inside) the weight of cover to be not less than 4.50 kg and frame to be not
less than 2.70kg as per standard design:
19.4.3.1 180x150 mm size P type With FPS bricks each 70.00 2,517.95 1,76,256.50
19.14 19.21.1 Making connection of drain or sewer line with existing manhole including breaking
into and making good the walls, floors with cement cincrete 1:2:4 mix (1cement: 2
coarse sand : 4 graded stone aggregate 20mm nominal size) cement plastered on
both sides with cement mortar 1:3 (1cement : 3 coarse sand) finished with a
floating coat of neat cement and making necessary channels for the drain etc.
complete for pipes 100 to 230mm dia.
19.15 Making soak pit 2.5 m diameter 3.0 metre deep with 45 x 45 cm dry brick honey
19.32 comb shaft with bricks and S.W. drain pipe 100 mm diameter, 1.8 m long complete
as per standard design.
With common burnt clay F.P.S. (non modular) bricks of
class designation 7.5
19.16 19.33 Constructing soak pit 1.20x1.20x1.20 m filled with brickbats including S.W. drain
pipe 100 mm diameter and 1.20 m long complete as per standard design.
Total of sub-head (19.0) (DSR) 39,51,930.95
20.0 External Storm Water Drainage System
20.01 2.10 Excavating trenches of required width for pipes, cables, etc including excavation
for sockets, and dressing of sides, ramming of bottoms, for all depth, including
getting out the excavated soil, and then returning the soil as required, in layers not
exceeding 20 cm in depth, including consolidating each deposited layer by
ramming, watering, etc. and disposing of surplus excavated soil as directed, within
2.10.1 All kinds of soil
2.10.1.2 Pipes, cables etc. exceeding 80 mm dia. but not
exceeding 300 mm dia
2.10.1.3 Pipes, cables etc. exceeding 300 mm dia but not exceeding 600 mm Metre 12.00 458.10 5,497.20
20.02 2.13 Excavating trenches of required width for pipes, cables, etc, including excavation
for sockets, depth upto 1.5 m, including getting out the excavated materials,
returning the soil as required in layers not exceeding 20 cm in depth, including
consolidating each deposited layers by ramming, watering etc., stacking serviceable
material for measurements and disposal of unserviceable material as directed,
within a lead of 50 m :
2.13.1 Ordinary rock
2.13.1.2 Pipes, cables etc. exceeding 80 mm dia but not exceeding 300 mm dia Metre 30.00 825.30 24,759.00
2.13.1.3 Pipes, cables exceeding 300 mm dia but not exceeding 600 mm dia Metre 1.00 949.60 949.60
20.03 19.6 Providing and laying non-pressure NP2 class (light duty) RCC pipes with collars
jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2
fine sand) including testing of joints etc. complete. (for storm drainage)
20.04 19.3 Providing and laying cement concrete 1:5:10 (1 cement : 5 coarse sand : 10 graded
stone aggregate 40 mm nominal size) up to haunches of S.W. pipes including bed -
concrete as per standard design :
19.3.2 150 mm diameter S.W. pipe /RCC pipes Metre 75.00 689.75 51,731.25
19.3.4 250 mm diameter S.W. pipe /RCC pipes Metre 75.00 943.90 70,792.50
19.3.5 300 mm diameter S.W. pipe/RCC pipes Metre 100.00 1,089.10 1,08,910.00
analysed 450 mm diameter S.W. pipe/RCC pipes Metre 13.00 1,155.00 15,015.00
20.05 19.2 Providing and laying cement concrete 1:5:10 (1 cement : 5 coarse sand : 10 graded
stone aggregate 40 mm nominal size) all-round S.W. pipes including bed concrete
as per standard design :
19.2.2 150 mm diameter S.W. pipe Metre 25.00 1,095.15 27,378.75
19.2.4 250 mm diameter S.W. pipe Metre 25.00 1,476.35 36,908.75
20.06 19.27 Constructing brick masonry road gully chamber 50x45x60 cm with bricks in
cement mortar 1:4 (1 cement : 4 coarse sand) including 500x450 mm pre-cast -
R.C.C. horizontal grating with frame complete as per standard design :
19.27.1 With common burnt clay F.P.S. (non modular) bricks of
class designation 7.5
20.07 19.19 Providing and fixing in position pre-cast R.C.C. manhole cover and frame of
required shape and approved quality
S. No. Description Unit Quantity Rate Amount (In Rs)
19.19.1.1 Rectangular shape 600x450mm internal dimensions Each 6.00 1,255.25 7,531.50
20.08 9.50 Providing and fixing hard drawn steel wire fabric 75x25 mm mesh of weight not
less than 7.75 Kg per sqm to window frames etc. including 62x19 mm beading of
second class teak wood and priming coat with approved steel primer all complete.
20.09 12.41 Providing & fixing on wall face unplasticised -Rigid PVC rain water pipes
conforming to IS:13592 Tyape A included jointing with seal ring conforning to -
IS:5382 leaving 10 mm gap for thermal expansion. (i)Single socketed pipes.
20.10 23.1 Boring/drilling bore well of required dia for casing/ strainer pipe, by suitable
method prescribed in IS:2800(Part I ), including collecting sample from different
strata , preparing and submitting strata chart/ bore log, including hire & running
charges of all equipments, tools, plants & machineries required for the job, all
complete as per direction of Engineer-in-charge, upto 90m depth below ground
23.1.1 All types of Soil -
20.11 23.3 Supplying, assembling, lowering and fixing in vertical position in bore well,
unplasticized PVC. medium well casing (CM) pipe of required dia, conforming to
IS: 12818, including required hire & labour charges, fittings & accessories, all -
complete, for all depths, as per direction of Engineer-in-charge.
23.3.2 150mm nominal size dia Metre 100.00 668.50 66,850.00
20.12 23.4 Supplying, assembling, lowering and fixing in vertical position in bore well,
unplasticized PVC. medium well screen(RMS) pipes with ribs, conforming to IS:
12818, including required hire & labour charges, fittings & accessories, all
complete, for all depths, as per direction of Engineer-in-charge.
23.4.2 150 mm nominal size dia Metre 80.00 681.90 54,552.00
20.13 23.5 Supplying, filling, spreading & levelling stone boulders of size range 5cm to 20cm,
in recharge pit, in the required thickness, for all leads & lifts, all complete as per cum 4.00 1,302.30 5,209.20
direction of Engineer-in-charge.
20.14 23.6 Supplying, filling, spreading & levelling gravel of size range 5mm to 10mm, in
recharge pit, over the existing layer of boulders, in required thickness, for all leads cum 4.00 1,309.00 5,236.00
& lifts, all complete as per direction of Engineer-in-charge.
20.15 23.7 Supplying, filling, spreading & levelling coarse sand of size range 1.5mm to 2mm,
in recharge pit, in required thickness over gravel layer, for all leads & lifts, all cum 4.00 1,309.00 5,236.00
complete as per direction of Engineer-in-charge.
20.16 23.9 Providing and fixing factory made precast RCC perforated drain covers, having
concrete of strength not less than M-25, of size 1000 x 450x50 mm, reinforced with
8 mm dia four nos longitudinal & 9 nos cross sectional T.M.T. hoop bars, including
providing 50 mm dia perforations @ 100 to 125 mm c/c, including providing edge
binding with M.S. flats of size 50 mm x 1.6 mm complete, all as per direction of
Engineer-in- charge.
20.17 23.15 Providing and fixing Bail plug/ Bottom plug of required dia to the bottom of pipe
assembly of tube well as per IS:2800 (part I).
20.18 Derived from Constructing brick masonry open surface drain with bricks of class designation 75
DSR 2021 in cement mortar 1:4 (1 cement : 4 fine sand) including 10 cm thick bed concrete
1:5:10 (1 cement: 5 fine sand : 10 graded stone aggregate 40 mm nominal size) and
25 mm thick cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone
aggregate 12.5 mm nominal size) for filling haunches including 12 mm cement
plaster 1:4 (1 cement : 4 coarse sand) with a floating coat of neat cement inside the
drain, its top and exposed side including disposal of surplus earth complete as per
standard design:
a) 25 cm drain 30 cm average depth, With F.P.S. bricks each 600.00 10,11,510.00
20.19 Derived from Extra for additional depth for brick masonry open surface drain :
DSR 2021 a) 25 cm drain 30 cm depth, with common burnt clay F.P.S. (non modular) bricks Metre 300.00 428.05 1,28,415.00
of class designation 7.5
Total of sub-head (20.0) (DSR) 30,35,243.15
21 EXTERNAL WATER SUPPLY SYSTEM AND PUMPS
DISTRIBUTION NETWORK FOR FRESH WATER SUPPLY
21.01 18.12 Providing and fixing G.I. pipes complete with G.I. fittings including ,trenching and
18.12.3 25mm nominal bore Metre 110.00 417.95 45,974.50
18.12.5 40mm nominal bore Metre 125.00 558.35 69,793.75
18.12.6 50mm nominal bore Metre 70.00 654.20 45,794.00
18.12.7 65mm nominal bore Metre 35.00 768.60 26,901.00
18.12.8 80mm nominal bore Metre 25.00 919.10 22,977.50
21.02 18.40 Painting GI pipes and fittings with two coats of anti corrosive bitumastic paint of
approved quality
18.40.3 25 mm dia, nominal bore Metre 110.00 15.25 1,677.50
S. No. Description Unit Quantity Rate Amount (In Rs)
18.40.4 32 mm dia, nominal bore Metre 285.00 18.40 5,244.00
18.40.5 40 mm dia, nominal bore Metre 125.00 20.95 2,618.75
18.40.6 50 mm dia, nominal bore Metre 70.00 25.25 1,767.50
18.40.7 65 mm dia, nominal bore Metre 35.00 31.30 1,095.50
18.40.8 80mm nominal bore Metre 25.00 36.40 910.00
21.03 18.17 Providing and fixing gun metal gate valve with C.I. wheel of approved quality
(screwed end) :
external works -
18.17.2 32 mm dia, nominal bore Each 13.00 589.90 7,668.70
18.17.4 50mm nominal bore Each 3.00 707.30 2,121.90
21.04 Providing and filling sand of grading zone V or coarser grade all-round the G.I.
pipes in external work.
21.05 18.59 Providing and fixing C.I. double acting air valve of approved quality with bolts,
nuts, rubber insertions etc. complete (The tail pieces, tapers etc if required will be -
paid separately) :
18.32.1 Constructing masonry chamber 30x30x50 cm,inside with 75 class designation brick
work in cement mortar 1:4 (1 cement:4 coarce sand) for stop cock complete with
C.I. surface box 100x100x75mm (inside) with locking arrangement and RCC top
slab 1:2:4 mix (1 cement : 2 corase sand: 4 graded stonr aggregate 20mm nominal
size) necessary excavation foundation concret 1:5:10 (1 cement:5 fine sand : 10 Each 42.00 1,800.30 75,612.60
graded stone aggregate 40 mm nominal size) and inside plastering with cement
mortor 1:3 (1 cement : 3 coarse sand) 12 mm thick finished with a floating coat of
neat cement complete as per standard design.
21.06 18.33 Constructing masonry Chamber 60x60x75 cm inside, in brick work in cement
mortar 1:4 (1 cement : 4 coarse sand) for sluice valve, with C.I. surface box 100mm
top diameter, 160 mm bottom diameter and 180 mm deep ( inside) with chained lid
and RCC top slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate
20mm nominal size ) , i/c necessary excavation, foundation concrete 1:5:10 (1 -
cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size) and inside
plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12 mm thick, finished
with a floating coat of neat cement complete as per standard design :
18.33.1 With common burnt clay F.P.S.(non modular) bricks of
class designation 7.5
21.07 18.34 Constructing masonry Chamber 90x90x100 cm inside, in brick work in cement
mortar 1:4 (1 cement : 4 coarse sand) for sluice valve, with C.I. surface box 100
mm top diameter, 160 mm bottom diameter and 180 mm deep (inside) with chained
lid and RCC top slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone
aggregate 20 mm nominal size ), i/c necessary excavation, foundation concrete
1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size ) -
and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12 mm
thick, finished with a floating coat of neat cement complete as per standard design :
18.34.1 With common burnt clay F.
18.34.1 With common burnt clay F.P.S.(non modular) bricks of class designation 7.5 Each 3.00 17,577.90 52,733.70
21.08 18.13 Making connection of G.I. distribution branch with G.I. main of following sizes by
providing and fixing tee, including cutting and threading the pipe etc. complete :
21.09 ELECT. DSR BUTTERFLY VALVE (MANUAL) with C I body SS disc nitrile sheet & O - ring
2022/ 16.11.1 & PN 16 pressure rating as specified.
21.10 ELECT. DSR NON - RETURN VALVE with dual plate of C I body SS plates vulcanized NBR
2022 / 16.11.2 seal flanged end & PN 16 pressure rating as specified.
21.11 ELECT. DSR Providing and fixing GI pipes medium class conforming to IS 1239 with GI fittings
2022 / 14.13 including cutting hole chase painted with primer, two coats of enamel paints etc -
Total of sub-head (21.0) (DSR) 7,22,294.20
22.0 Bore Well Installations (As per D.S.R)
S. No. Description Unit Quantity Rate Amount (In Rs)
22.01 23.1 Boring/drilling bore well of required dia for casing/ strainer pipe, by suitable
method prescribed in IS: 2800 (part I), including collecting samples from different
strata, preparing and submitting strata chart/ bore log, including hire & running
charges of all equipments, tools, plants & machineries required for the job, all
complete as per direction of Engineer -in-charge, upto 90 metre depth below
23.1.1 All types of soil
23.1.2 Rocky strata including Boulders -
23.3 Supplying, assembling, lowering and fixing in vertical position in bore well,
unplasticized PVC medium well casing (CM) pipe of required dia, conforming to
IS: 12818, including required hire and labour charges, fittings & accessories etc. all Meter
complete, for all depths, as per direction of Engineer -in-charge.
22.02 23.4 Supplying, assembling, lowering and fixing in vertical position in bore well
unplasticized PVC medium well screen (RMS) pipes with ribs, conforming to IS:
12818, including hire & labour charges, fittings & accessories etc. all complete, for -
all depths, as per direction of
Engineer-in-charge.
23.4.3 200 mm nominal size dia metre 40.00 1,099.25 43,970.00
22.03 23.8 Gravel packing in tubewell construction in accordance with IS: 4097, including
providing gravel fine/ medium/ coarse, in required grading & sizes as per actual cum 14.00 1,479.25 20,709.50
requirement, all complete as per direction of Engineer-in-charge.
22.04 23.12 Development of tube well in accordance with IS : 2800 (part I) and IS: 11189, to
establish maximum rate of usable water yield without sand content (beyond
permissible limit), with required capacity air compressor, running the compressor
for required time till well is fully developed, measuring yield of well by "V" notch
method or any other approved method, measuring static level & draw down etc. by hour 72.00 916.80 66,009.60
step draw down method, collecting water samples & getting tested in approved
laboratory, i/c disinfection of tubewell, all complete, including hire & labour
charges of air compressor, tools & accessories etc., all as per requirement and
direction of Engineer-in-charge.
22.05 23.13 Providing and fixing suitable size threaded mild steel cap or spot welded plate to
the top of bore well housing/ casing pipe, removable as per requirement, all
complete for borewell of:
23.13.3 200 mm nominal size dia Each 2.00 280.95 561.90
22.06 23.14 Providing and fixing M.S. clamp of required dia to the top of casing/ housing pipe
of tubewell as per IS: 2800 (part I), including necessary bolts & nuts of required -
22.07 23.15 Providing and fixing Bail plug/ Bottom plug of required dia to the bottom of pipe
assembly of tubewell as per IS:2800 (part I).
Total of sub-head (22.0) (DSR) 4,07,356.00
SCHEDULE OF QUANTITIES
Construction of Eklavya Model Residential School (EMRS)” at Darbha, District- Bastar Chhattisgarh
S. No. Description Unit Quantity Rate Amount (In Rs)
FIRE FIGHTING WORKS
23.0 DSR-2022 PIPING & VALVES
23.01 18.7 Providing, laying, testing & commissioning of 'C' class heavy duty MS pipe conforming to IS
3589/IS 1239 including Welding, fittings like elbows, tees, flanges ,tapers, nuts bolts, gaskets
etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with
two or more coats of synthetic enamel paint of required shade complete as required :
23.02 14 Providing, installation, testing and commissioning of non-return valve of following sizes - -
confirming to IS:5312 complete with rubber gasket, GI bolts, nuts,washers etc.as required :
23.03 18.17 Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) : -
23.04 11 Supplying, fixing, testing and commissioning of butterfly valve of PN 1.6 rating with - -
bronze/gunmetal seat duly ISI marked complete with nuts, bolts, washers, gaskets conforming
to IS 13095 of following sizes as required :
23.05 15 Providing, installation, testing and commissioning of stainless steel Y-strainer fabricated - -
out of 1.6 mm thick stainless steel, Grade 304, sheet with 3 mm dia holes with stainless
23.06 MR 1 Providing and fixing 150 mm dial diameter size Pressure gauge (0-15 Kg/Cm2) complete with Nos 3.00
shut off valve duly calibrated before installation complete as required & as per enclosed
specification. 711.16 2,133.48
Total of sub-head (23.0) (DSR) 6,38,081.30
Total of sub-head (23.0) (NON DSR) 2,133.48
24.0 FIRE HYDRANT ACCESSORIES - -
18.17 Supplying and fixing first-aid Hose Reel with MS construction spray painted in post office red,
conforming to IS 884 complete with the following as required. 20 mm nominal internal dia water
hose thermoplastic (Textile reinforced) type -2 as per IS: 12585 20 mm nominal internal dia
gun metal globe valve & nozzle. Drum and brackets for fixing the equipmets on wall.
Connections from riser with 25 mm dia stop gun metal valve & M.S. Pipe and socket.
Total of sub-head (24.0) (DSR) 1,56,150.00
25.0 FIRE EXTINGUISHERS & MISC. ITEMS - -
Providing and fixing Carbon-di-oxide fire extinguishers consisting of welded M.S cylindrical
body, squeeze lever discharge valve fitted with internal discharge tube, 30cms long high
pressure discharge hose, discharge nozzle, suspension bracket, confirming to IS : 15683
25.01 MR finished externally with red enamel paint and fixed to wall with brackets with rawl plug/dash Nos 2.00 7,513.02 15,026.04
fasteners complete with internal charge. Capacity 4.5 kg. ISI Marked.( Contractor should
submit test certificate form manufacturer along with serial number of every extinguishers
Providing and fixing (ABC Dry Chemical Powder ) type Fire Extinguisher of Capacity 6 kg
Confirms to IS 15683, bearing ISI mark complete with brass forged squeeze grip type valve
fitted with pressure gauge , pressurize with dry Nitrogen gas filled, with discharge nozzle with
wall mounting bracket (rubber gripped) complete with internal charges. ( Contractor should
submit test certificate form manufacturer along with serial number of every extinguishers
Providing and fixing water Carbon-di-oxide (ISI marked) extinguishers including all
accessories as per IS specification with wall bracket with rawl plug complete as reqd.(
Contractor should submit test certificate form manufacturer along with serial number of every
extinguishers supplied.)
Digitally signed by VARUN
S. No. Description Unit Quantity Rate Amount (In Rs)
Capacity 9 Litres
Total of sub-head (25.0) (Non DSR) 94,005.98
26.0 FIRE PUMPS & ACCESSORIES - -
18.4 Supplying, installation, testing and commissioning of electric driven terrace pump
26.01 suitable for automatic operation and consisting of following, complete in all respects, as - -
required: (Terrace Pump)
(a) Horizontal type, multistage, centrifugal, split casing pump of cast iron body & bronze
impeller with stainless steel shaft, mechanical confirming to IS : 1520
b) Suitable HP squirell cage induction motor TEFC type suitable for operation on 415
volts, 3 phase, 50 Hz, AC supply with IP55 class of protection for enclosure, horiziontal
foot mounted type with Class-'F' insulation,
conforming to IS-325.
(c) M.S.fabricated common base plate, coupling, coupling guard, foundation bolts etc.as
(d) Suitable cement concrete foundation duly plastered and with anti vibration pads. - -
Providing and fixing rubber expansion joint (to provide relief from stresses at pipe flanges) as
per specification of the manufacturers and direction of Engineer in chief PN-16 rating
Supplying and fixing air vessel made of 250 mm dia, 8 mm thick MS sheet, 1200 mm in height
with air release valve on top and flanged connection to riser, drain arrangement with 25 mm dia
gun metal wheel valve with required accessories, pressure gauge and paintingwith synthetic
enamel paint of approved shade as required.
"Providing, fixing, testing and commissioning of control panel for Terrace Booster pumps.
Incoming: MCCB 35A 1 set of Phase indicating lamps, 1 set of 35A Al bus bars, 1No
Ammeter, 1No Voltmeter with phase selector switch Feeder for Booster Pumps - 1 No. 1 No.
26.04 MR 32A TP MCCB without releases. DOL starter with over load relay, single phase preventor and Nos 3.00 36,273.41 1,08,820.23
indicating lamps with ON/OFF push buttons. 1 No. Automanual selector switch. Suitable for
Total of sub-head (26.0) (DSR) 3,13,341.00
Total of sub-head (26.0) (Non DSR) 1,10,590.23
ELECTRICAL WORKS (Internal)
27.0 Internal Wiring
Point wiring in PVC conduit, with modular type switch :-
27.01 1.10 Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC
insulated copper conductor single core cable in surface / recessed medium class PVC conduit,
with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm
FRLS PVC insulated
copper conductor single core cable etc. as required.
27.02 1.55 Wiring for group controlled (looped) light point/ fan point/ exhaust fan point/ call bell point
(without independent switch etc) with 1.5 sq.mm FRLS PVC insulated copper conductor single
core cable in surface / recessed PVC conduit, and earthing the point with 1.5 sq.mm FRLS
PVC insulated copper conductor single core cable etc as required. (Note: To be
provided in class rooms in school bldg./ common areas/ toilets/ corridors etc.)
1.55.2 Group B Point 753.00 -
27.03 1.11 Wiring for twin control light point with 1.5 sq.mm FRLS PVC insulated copper conductor Point 30.00
single core cable in surface / recessed medium class PVC conduit, 2 way modular switch,
modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated
copper conductor single core cable 1,562.00 46,860.00
etc. as required.
Power plug wiring in PVC conduit (2 x 4 Sq.Mm.) :-
Digitally signed by VARUN
S. No. Description Unit Quantity Rate Amount (In Rs)
27.04 1.12 Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single Metre 5080.00
core cable in surface/ recessed medium class PVC conduit alongwith 1 No. 4 sq. mm FRLS
PVC insulated copper conductor single core cable for loop earthing as required.
Power plug wiring in PVC conduit (4 x 4 Sq.Mm.) :-
27.05 1.13 Wiring for light/ power plug with 4X4 sq. mm FRLS PVC insulated copper conductor single Metre 1367.00
core cable in surface/ recessed medium class PVC conduit alongwith 2 No. 4 sq. mm FRLS
PVC insulated copper conductor single core cable for loop earthing as required.
Circuit / Sub main wiring in PVC conduit :-
27.06 1.14 Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC
insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit
1.14.9 4 x 6 sq.mm. + 2 x 6 sq.mm. Earth wire Metre 105.00 754.00 79,170.00
S/F light plug point Modular Type Accessories :-
27.07 1.31 Supplying and fixing suitable size GI box with modular plate and cover in front on surface or Each 908.00
in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular
switch, connections etc. as required.
S/F power plug point modular Type Accessories :-
27.08 1.32 Supplying and fixing suitable size GI box with modular plate and cover in front on surface or Each 368.00
in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 586.00 2,15,648.00
A modular switch, connections etc. as required.
27.09 2.18 Supplying and fixing 20 A, 240 V, SPN Industrial type socket outlet, with 2 pole and earth, Each 32.00
metal enclosed plug top alongwith 20 A "C" curve, SP, MCB, in sheet steel enclosure, on
surface or in recess, with chained metal cover for the socket out let and complete with 1,621.00 51,872.00
connections, testing and commissioning etc. as required.
27.10 1.38 Supplying and fixing call bell/ buzzer suitable for single phase, 230 V, complete as required. Each 33.00
27.11 1.56 Supplying and fixing suitable size GI box with modular plate and cover in front on surface or 48.00
in recess, including providing and fixing 2 nos. of 3 pin 5/6 A modular socket outlet and 2 nos. 676.00 32,448.00
of 5/6 A modular switch, connections etc. as required.
Total of sub-head (27.0) (DSR) 86,62,207.00
28.0 Distribution Boards & MCB'S
28.01 2.10 Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, "C" curve, miniature circuit
breaker suitable for inductive load of following poles in the existing MCB DB complete with
connections, testing and commissioning etc. as Required.
2.10.5 Triple pole and neutral Each 1.00 1,228.00 1,228.00
28.02 2.11 Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as Each 30.00
28.03 2.4 Supplying and Fixing Following way, Horizontal Type Three Pole and Neutral, Sheet Steel,
MCB Distribution Board, 415 V, on surface/ recess, complete with tinned copper bus bar,
neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as
required. (But without MCB/RCCB/Isolator).
28.04 2.3 Supplying and fixing following way, Single Pole and Neutral, sheet steel, MCB distribution
board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth
bar, din bar, interconnections, powder painted including earthing etc. as required. (But without
MCB/RCCB/Isolator).
Digitally signed by VARUN
S. No. Description Unit Quantity Rate Amount (In Rs)
S/F DP Isolator
28.05 2.12 Supplying and fixing following Rating, Double pole, 240 V, isolator in the existing MCB DB
complete with connections, testing and commissioning etc. as Required.
S/F 4P Isolator
28.06 2.13 Supplying and fixing following rating, four pole, 415 V, isolator in the existing MCB DB
complete with connections, testing and commissioning etc. as Required.
28.07 2.14 Supplying and fixing following rating, double pole, (single phase and neutral), 240 V, residual
current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB
complete with connections, testing and commissioning etc. as Required.
28.08 2.15 Supplying and fixing following rating, Four pole, (Threee phase and neutral), 415 V, residual
current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB
complete with connections, testing and commissioning etc. asrequired.
28.09 2.5 Supplying and fixing of following ways surface/ recess mounting, vertical type, 415 V, TPN
MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 A
tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but
without MCBs and incomer ) as required . (Note : Vertical type MCB TPDB is normally used
where 3 phase outlets are required.)
28.10 2.23 Supplying and fixing Cable End Box (Loose Wire Box) suitable for following single pole and
neutral, sheet steel, MCB distribution board, 240 Volts, on surface/ recess, complete with
testing and commissioning etc. as required.
2.23.1 For 6 way, Double door SPN MCB DB Each 8.00 752.00 6,016.00
2.23.2 For 8 way, Double door SPN MCB DB Each 9.00 832.00 7,488.00
2.23.3 For 14 way, Double door SPN MCB DB Each 29.00 902.00 26,158.00
28.11 2.24 Supplying and fixing Cable End Box (Loose Wire Box) suitable for following tripole pole and
neutral, sheet steel, MCB distribution board, 415 Volts, on surface/ recess, complete with
testing and commissioning etc. as required.
2.24.1 For 4 way, Double door TPN MCBDB Each 4.00 1,080.00 4,320.00
2.24.2 For 6 way, Double door TPN MCBDB Each 9.00 1,124.00 10,116.00
2.24.3 For 8 way, Double door TPN MCBDB Each 20.00 1,340.00 26,800.00
28.12 2.16 Supplying and fixing DP sheet steel enclosure on surface/recess along with 25/32 A 240V "C" Each 31.00
Curve DP MCBcomplete with connections, testing and commissioning etc. as required. ( For 1,169.00 36,239.00
Qtrs Emergency Supply)
28.13 MR Supplying and fixing following rating, Single/ double/ three pole, 230/ 415 volts, MCB "C"
curve in the existing MCB DB complete with connections, testing and commissioning etc. as
Total of sub-head (28.0) (DSR) - 9,69,978.00
Total of sub-head (28.0) (Non-DSR) 1,541.38
29.0 Telephone, Television & Data System (Socket,Wiring & Conduting Only) -
S/F Modular Boxes, Base & Cover Plate :- -
29.01 1.27 Supplying and Fixing Following Size/ Modules, GI Box Alongwith Modular Base & Cover -
Plate for Modular Switches in Recess etc. as Required.
1.27.2 3 Module (100mmX75mm) Each - 327.00 -
S/F Modular Type Switch / Socket :- -
29.02 1.24 Supplying and Fixing Following Modular Switch/ Socket on The Existing Modular plate & -
Switch Box including connections But Excluding Modular Plate etc. as required.
1.24.6 Telephone Socket outlet. Each 59.00 148.00 8,732.00
1.24.7 TV Antenna socket outlet. Each 38.00 148.00 5,624.00
Digitally signed by VARUN
S. No. Description Unit Quantity Rate Amount (In Rs)
29.03 1.21 Supplying and fixing of following sizes of medium class PVC conduit along with accessories in -
surface/recess including cutting the wall and making good the same in case of recessed conduit
29.04 1.18 Supplying and drawing following pair 0.5 mm dia FRLS PVC insulated annealed copper -
conductor, Unarmored Telephone cable in the existing surface/ recessed steel/ PVC conduit as
29.05 1.19 Supplying and drawing co-axial TV cable RG-6 grade, 0.7 mm solid copper conductor PE Metre 620.00
insulated, shielded with fine tinned copper braid and protected with PVC sheath in the existing 47.00 29,140.00
surface/ recessed steel/ PVC conduit as required.
29.06 1.53 Supplying and drawing of UTP 4 pair CAT 6 LAN Cable in the existing surface/ recessed -
Steel/ PVC conduit as required.
29.07 MR 1 SITC Modular Type Computer jack RJ 45 ISI mark 1 Module on existing Mounting plate and Each 79.00
Total of sub-head (29.0) (DSR) - 6,35,112.00
Total of sub-head (29.0) (Non DSR) - 16,480.19
30.0 Internal Lighting Fixtures & Fans -
30.01 MR 2 Supply of 20 Watt LED light Wall Mounted BRACKET light fitting Sutaible for 220 volts Each 1.00
Single Phase A C Supply complete with all accessories as required.
30.02 MR 3 Supply of Surface Mounted Energy Efficient, LED Luminaires 12W LED DOWN LIGHT Each 68.00
(Round) Sutaible for 220v Single Phase Supply complete with driver circuit including making
connections etc.as required. (Technical Data - System power 12W, CRI ≥80, Power Factor 778.59 52,944.12
≥0.95, System Luminous Efficacy ≥94).
30.03 MR 4 Supply of Surface Mounted Energy Efficient, LED Luminaires 15W LED DOWN LIGHT Each 35.00
(Round) Sutaible for 220v Single Phase Supply complete with driver circuit including making
connections etc.as required. (Technical Data - System power 15W, CRI ≥80, Power Factor 834.43 29,205.05
≥0.95, System Luminous Efficacy ≥94).
30.04 MR 5 Supplying and fixing brass batten/ angle holder including 20 w LED Lamp, connection Each 490.00
etc. as required. 316.07 1,54,874.30
30.04 MR 5 Supply, of Linear & Compact 10W Mirror Light with Decorative Grey Caps, Polycarbonate Each 2.00
Body & Ribbed Opal Diffuser. (Technical Data - System power 10W, CRI ≥80, Power Factor 287.63 575.26
≥0.95, System Luminous Efficacy ≥100)
30.05 MR 6 Supply of LED Luminaires BATTEN 40W LED Tube Light of Box Type prewired Indoor Each 330.00
Luminaire with Energy Efficient Electronic Ballast, with End Caps Complete as Required.
(Technical Data - System power 40W, CRI ≥80, Power Factor ≥0.95, System Luminous 946.11 3,12,216.30
30.06 MR 7 Supply of LED Luminaires BATTEN 20W LED Tube Light of Box Type Prewired Indoor Each 765.00
Luminaire with Energy Efficient Electronic Ballast, with End Caps Complete as
Required.(Technical Data - System power 20W, CRI ≥80, Power Factor ≥0.95, System 399.30 3,05,464.50
Luminous Efficacy ≥100)
30.07 MR 8 Supplying and fixing of Bulk Head with 10 Watt LED lamp fitting Sutaible for 230 volts Single Each 50.00
Phase A C Supply complete with all accessories as required.
SUPPLY FANS & EXHAUST FANS - - -
30.08 MR 8 Supply, of following size sweep, BEE 5 star rated, white colour ceiling fan with all -
accessories i.e. 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope,
copper winding, safety pin,nut bolts, washers, , suitable for 230 V, 50 Hz, single phase AC - -
Supply, earthing etc. complete as required.
30.09 MR9 Supply of following sweep heavy duty metal body exhaust fan/wall fan/ fresh air ( ventilating ) -
plastic body fan with guard suitable operation on single phase 230 V, 50Hz. AC Supply, with
lowers / shutters in the existing opening. (Crompton - Trans Air 300/200mm/Approved
Equivalent in Usha/Havells/Bajaj)
(a) 200 mm sweep 900 RPM ( in plastic body)Ventilating fan fan Nos 15.00 1,088.34 16,325.10
Digitally signed by VARUN
S. No. Description Unit Quantity Rate Amount (In Rs)
(b) 300 mm sweep 900 RPM ( in plastic body)Ventilating fan 26.00
(c) 300 mm sweep 900 RPM ( In metal body) exhaust fan Nos 40.00 3,026.91 1,21,076.40
(d) 450 mm sweep 900 RPM ( In metal body) exhaust fan Nos 17.00 4,772.68 81,135.56
e) 400 mm sweep oscillating type four speed wall mounting fan Nos. 14.00
Erection Of Lighting Fixtures And Fans -
30.10 1.41 Installation, testing and commissioning of pre-wired, fluorescent fitting / compact fluorescent Each 1,201.00
fitting of all types, complete with all accessories and tube/lamp etc. directly on ceiling/ wall,
including connections with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core
cable and earthing etc. as required. 206.00 2,47,406.00
30.11 1.45 Installation, testing and commissioning of ceiling fan, including wiring the down rods of Each 568.00
standard length (upto 30 cm) with 1.5 sq. mm FRLS PVC insulated, copper conductor, single
core cable, including providing and fixing phenolic laminated sheet cover on the Fan Box etc. 339.00 1,92,552.00
30.12 1.50 Installation of Exhaust/wall fan in the existing opening, including making good the damage, -
Connection, Testing, Commissioning etc. as Required.
S/F modular type electronic fan regulator: - - -
30.13 1.25 Supplying and fixing Two Module Stepped Type Electronic Fan Regulator on the existing Each 568.00
modular plate switch box including connections but excluding modular plate etc. as required. 369.00 2,09,592.00
Fixing Louvers / Shutters for Exhaust Fan: - - -
30.14 1.51 Extra for Fixing the Louvers/ Shutters Complete with Frame for a Exhaust Fan of all sizes. Each 57.00
Extra Down GI Pipe 15mm Dia: - - -
30.15 1.47 Supplying and Fixing Extra Down Rod of 10 cm Length G.I. pipe, 15 mm dia, heavy gauge Each 516.00
including painting etc. as required. (Note : More than 5 cm length shall be rounded to the 46.00 23,736.00
nearest 10 cm and 5 cm or less shall be ignored).
Total of sub-head (30.0) (Non DSR) - 22,78,618.19
Total of sub-head (30.0) (DSR) - 7,35,485.00
ELECTRICAL WORKS (External)
31.0 Transformer and HT Panel
31.01 MR 1 11KV HT VCB PANEL - IN DOOR TYPE
Supplying, installation, testing and commissioning of IN DOOR Type, floor mounting, 11KV
HT panel unit made out of M.S sheet steel clad dust and vermin proof with necessary control
fuses/MCBs, Termination arrangements for Incoming and Outgoing Cable of 3Cx120 Sq.mm
Al.HT XLPE cable, and earthed cable, Terminal Blocks, Earthing, Powder coated painting,
Sign writing and Base channels etc. with complete all accessories as required. as per
Requirements comprising of the following.
INCOMING : - -
i) 630Amps, 11kV, 3 phase 50Hz, 21KA / 3Sec, Draw-out type Vacuum Circuit Breaker. fitted
with 230V AC spring charging motor, 110V DC tripping and closing coils, 8NO+8NC Aux.
conductor mechanical on off indicator, spring charging / discharge Indication, automatic safety
shutter and with anti-pumping feature with necessary required accessories.
ii) 3 phase 11 KV/110 Volts PT, class 1 accuracy and 100 VA burden with 1 No Voltmeter (0-
15 kV), Digital type, selector switch for voltmeter and protection fuses for HT metering upto
12 kV on incomer.
iii) Dual core dual ratio 3 CTs 400/200/5+5A of 15 VA burden and accuracy class1.0 for
metering and class 5P10 for protection.
iv) (0-400 A) Ammeter, digital type with selector switch for Ammeter.
v) Digital Multifunction Meter.
vi) Microprocessor based numerical relay for Over current and Earth fault protection with
directional control.
vii) Phase indicating lamps with HRC fuses.
viii) Indicating lamps to indicate, RYB, ON, OFF, OPEN, CLOSE, TRIP, SPRING
CHARGED, TRIP CIRCUIT HEALTHY
ix) Test terminal block
x) Trip/Neutral/close switch
xi) Copper bus bar for earthing (common)
xii) master trip relay & trip circuit healthy supervision relay.
630 Amps, 11kV, 50Hz, 3Phase, 25 KA / 3Sec. Copper busbars.
The11KV HT VCB PANEL shall be complete with as per SLD and specifications. set 1.00 4,72,666.91 4,72,666.91
31.02 MR 2 11KV TRANSFORMER (11 KV /0.433 KV) (250 KVA) -
Digitally signed by VARUN
S. No. Description Unit Quantity Rate Amount (In Rs)
Supplying, installation, testing and commissioning of 250 kVA, (Energy efficiency Level -2) set 1.00
11kV / 433 Volts, 3 phase, 50Hz,vector group Dyn11 (delta -star connected), Indoor 'ONAN'
type, copper wound transformer with OFF load tap changing arrangement on HV side in steps
of +/- 2.5%, +/- 5% & +/- 7.5%, on H.V. side with HT cable chamber suitable for Heat
shrinkable joint with XLPE cable (cable entry from bottom) and LT connection chamber
suitable for connecting Bus duct arrangement and equipped with other essential accessories 7,70,666.43 7,70,666.43
including providing complete with all fittings, accessories etc. and lifting lugs i/c first filling of
filtered dehydrated oil, supplying grouting suitable MS Channel on the plinth for placing the
transformer etc., complete and confirming to IS 1180 (Part-1): 2014, level - 2 & section 3 of
CPWD General specification for Electrical works (Part -IV Substation 2013 as amended up to
date) and as per specifications.
(PLEASE NOTE THE TRASNFOREMR SHALL BE IN COMPLINACE WITH NEW
REGUALTION IS 1180 or Equivalent IEC Standard FOR LOSSES AND EFFICIENCY
and ammended upto date)
Total of sub-head (31.0) (Non DSR) 12,43,333.34
32.01 MR 3 Emergency Panel
Supply , installation, testing, Design, manufacture, supply inspection, handling,
assembling, affecting proper connections, testing and commissioning of 1.6/2mm
CRCA sheet steel fabricated cubical type Main L.T. Panel floor mounting Extensible
Type, dust & vermin proof, front operated construction, enclosure class - IP 42, As
per IEC 60439 after proper treatment with 9 tank process with top/bottom removable
gland plates, as required, double compression type cable glands, earth bus, hinged
and lockable doors to achieve dust and vermin proof complete with all inter
connections small wiring by min. 1.5-2.5 sq. mm. FR copper wires, ckt labels etc.
The panel feeders shall be suitable for terminating suitable nos. 3.5 / 4 core armoured
aluminium cable as required.
1 nos. 50 A 415V, 4P MCCB of 25kA with thermal magnetic release, overload, short circuit
and Earth fault protection.
1 no. Digital type Multifunction Meters to show (V, A, kWh, KVAh, KW, KVA, KVAR, PF,
Hz.) with cast resin CTs.
1 Set of phase indicating lamps with MCB protection.
9 nos. 20 A 4P MCB
4 nos. 32 A , 4P MCB
2 nos. 40 A , DP MCB
2 nos. 20 A 415V, 4P MCB of 10kA with 40A 4P Contactor & timer switch . 1.00 84,776.68 84,776.68
32.02 MR 4 Main LT PANEL -
NOTE:- MCCB's wherever specified upto 250A shall be Thermal Magnetic & Above -
250A will be Microprocessor based inbuilt protections.
Suppy , installation, testing, Design, manufacture, supply inspection, handling, assembling,
affecting proper connections, testing and commissioning of 1.6/2mm CRCA sheet steel
fabricated cubical type Main L.T. Panel floor mounting Extensible Type, dust & vermin proof,
front operated construction, enclosure class - IP 42, As per IEC 60439 after proper
treatment with 9 tank process with top/bottom removable gland plates, as required, double
compression type cable glands, earth bus, hinged and lockable doors to achieve dust and
vermin proof complete with all inter connections small wiring by min. 1.5-2.5 sq. mm. FR
copper wires, ckt labels etc. The panel feeders shall be suitable for terminating suitable nos.
3.5 / 4 core armoured aluminium cable as required.
All MCCB's shall be Ics = 100% Icu, with rotary handle & pad locking arrangement. All TP -
MCCB shall be with heavy duty solid isolable neutral link.
The breaking capacity specified for all MCCB's breakers is Ics value (service rating). -
Each Incoming (ACB/MCCB) shall have ON/OFF/Trip/ LED indication on panel Front door. -
The incoming MCCB shall be Microprocessor based with inbuilt O/L & S/C release with E/F -
protection and all Outgoings MCCB's shall be thermal-magnetic based with inbuilt O/L & S/C
Incoming From TRANSFORMER 1 (250 KVA) - 1 NOS. (Phase I)
Incomer : 1 Nos 400A TP MCCB 36KA with Thermal Magnetic Release -
1 No. Digital Ammeter -
1 No. Digital Voltmeter -
1 set of 3 CT's of ratio 400/5A, Class 1.0 accuracy 15 VA burden for Metering. -
1 set of 3 CT's of ratio 400/5A, Class 1.0 accuracy 15 VA burden for APFCR. -
3 Nos. LED Type phase indicating lamps, each lamp shall be with backup MCB -
3 Nos. LED Type Indicating lamp for indicating the status of feeder - ON / OFF / TRIP. Each -
lamp shall be with backup MCB.
Incoming From Supply Source-2 - 1 Nos 400A TP MCCB 36KA with Thermal Magnetic
Release (Phase II) - for future Feeder
Digitally signed by VARUN
S. No. Description Unit Quantity Rate Amount (In Rs)
BUS COUPLER : 1 Nos 400A TP MCCB 36KA . It should be positioned in such manner
so that all electrical loads are separated by separate bus bar chamber in the panel.
Interlocking : Electrical as well as Mechanical Interlocking between incomers and bus
coupler shall be executed in such a manner that only two sources should be in circuit at a
TPN Aluminium Bus Bars of Minimum 500 Amp with Heat shrinkable coloured sleeves , -
Shrouds at Joints and including DMC/SMC bus bars supports at required interval complete for
cross section, side supports and their spacing etc.
19 Nos. Outgoing Feeders :- -
1 Nos. 250A, FP 25KA MCCB (CAPACITOR PANEL) -
9 Nos. 160A, FP 25KA MCCB -
1 Nos. 200A, FP 25KA MCCB -
4 Nos. 100A, FP 25KA MCCB -
4 No 63 AMP 4P 10KA MCCB -
Spare space for 100A MCCB - 02 Nos. -
Complete Panel as Above and complete set 1.00 4,77,594.46 4,77,594.46
32.03 MR 5 AUTOMATIC POWER FACTOR CORRECTION PANEL (CAPACITOR PANEL) - -
Supplying, Installation, Testing and Commissioning of cubicle type capacitior panel suitable -
for 415 & 3 phase 50 HZ A.C. supply System fabricated in design from CRCA Sheet Steel of
with cover, 3Magnetic
Thermal mm thickBased
for gland plates
release i/c powder
(Ics=100% Icu)coating
b) 250A, 4 strip Tinned Aluminium busbar -1 Set -
c) Micro processor based automatic Power factor control relay i/c power factor metre in 8 steps -
d) Multi functional meters with suitable CTS and protection MCBS 1 set. -
e) 3 Nos. Phase indicating light (lamp) with MCBs protection. -
2 Set - 63A Amp TP MCCB 10 KA and Capacitor duly switching contactor for 20 KVAR -
capacity auto mannual selector switch start/stop puch button on/off indicatting lamp with
protection MCB & delay timer complete i/c 20 KVAR Normal Duty 440V capacitor bank with
inter Connection
4 Set -32 Amp TP MCCB 10 KA and Capacitor duly switching contactor for 10 KVAR -
capacity auto mannual selector switch start/stop puch button on/off indicatting lamp with
protection MCB & delay timer complete i/c 10 KVAR Normal Duty 440V capacitor bank with
inter Connection
2 Set - 16 Amp TP MCCB 10 KA and Capacitor duly switching contactor for 5 KVAR -
capacity auto mannual selector switch start/stop puch button on/off indicatting lamp with
protection MCB & delay timer complete i/c 5 KVAR Normal Duty 440V capacitor bank with
inter Connection
Capacitor panel should switch OFF when DG starts. Control wiring should be done for -
complete panel as above and complete set 1.00 1,74,937.11 1,74,937.11
32.04 MR 6 SCHOOL BUILDING MAIN DISTRIBUTION PANEL -
Design, manufacture, supply, installation, testing and commissioning of cubicle type -
panel fabricated out of CRCA sheet steel , floor mounted totally enclosed switchbaord
suitable for use of 415 volts , 3 phase, 50 HZ complete with aluminium bus bar and
all accessories including supply and fixing of following incoming and outgoing
switchgears, Panel Should Have Double Earthing Provision which connected to the
nearest earth grid.
NOTE:- MCCB's wherever specified upto 250A shall be Thermal Magnetic & Above -
250A will be Microprocessor based inbuilt protections.
INCOMER : 160 AMP FP MCCB -
3 Nos. Phase Indication light (lamp) with MCBs protection. -
Multi functional meters (VAF) with suitable CTS and protection MCBS 1 set. -
BUS BAR : 200 AMP, 500 Volts, 3 phase 50 HZ 4P high conductivity electrolytic -
Aluminium bus bar of suitable length, insulated by heat shrinkable sleeves. The
current density of bus bar shall be minimum 0.6 sq mm / amp.
The Maximum allowable temperature for the Bus bar to be restricted to 90 deg C. The -
temperature rise should be restricted to 45 deg C above ambient temperature.
OUT GOINGS : -
18 No 63 AMP FP MCB -
2 No 40 AMP DP MCB -
2 No 63 AMP DP MCB -
complete panel as above and complete set 1.00 1,33,445.36 1,33,445.36
32.05 MR 7 UPS PANEL -
Digitally signed by VARUN
S. No. Description Unit Quantity Rate Amount (In Rs)
Design, manufacture, supply, installation, testing and commissioning of cubicle type panel -
fabricated out of CRCA sheet steel , floor mounted totally enclosed switchbaord suitable for
use of 415 volts , 3 phase, 50 HZ complete with aluminium bus bar and all accessories
including supply and fixing of following incoming and outgoing switchgears, Panel Should
Have Double Earthing Provision which connected to the nearest earth grid.
INCOMER : 1 Nos 63 AMP FP MCCB (Thru Bypass Switch 10 KVA UPS) -
BUS BAR : 100 AMP, 500 Volts, 3 phase 50 HZ FP high conductivity electrolytic -
Aluminium bus bar of suitable length, insulated by heat shrinkable sleeves. The current density
of bus bar shall be minimum 06 sq mm / amp.
The Maximum allowable temperature for the Bus bar to be restricted to 90 deg C. The -
temperature rise should be restricted to 45 deg C above ambient temperature.
OUT GOINGS : -
3 No 63 AMP DP MCB i/c spare -
3 No 40 AMP DP MCB i/c spare -
complete panel as above and complete set 1.00 23,775.95 23,775.95
32.06 MR 8 BOYS HOSTEL MAIN DISTRIBUTION BOARD -
Design, manufacture, supply, installation, testing and commissioning of cubicle type -
panel fabricated out of CRCA sheet steel , floor mounted totally enclosed switchbaord
suitable for use of 415 volts , 3 phase, 50 HZ complete with aluminium bus bar and
all accessories including supply and fixing of following incoming and outgoing
switchgears, Panel Should Have Double Earthing Provision which connected to the
nearest earth grid.
NOTE:- MCCB's wherever specified upto 250A shall be Thermal Magnetic & Above -
250A will be Microprocessor based inbuilt protections.
INCOMER : 125 AMP FP MCCB -
3 Nos. Phase Indication light (lamp) with MCBs protection. -
Multi functional meters (VAF) with suitable CTS and protection MCBS 1 set. -
BUS BAR : 160 AMP, 500 Volts, 3 phase 50 HZ 4P high conductivity electrolytic -
Aluminium bus bar of suitable length, insulated by heat shrinkable sleeves. The
current density of bus bar shall be minimum 0.6 sq mm / amp.
The Maximum allowable temperature for the Bus bar to be restricted to 90 deg C. The -
temperature rise should be restricted to 45 deg C above ambient temperature.
OUT GOINGS : -
14 No 63 AMP FP MCB
2 No 40 AMP DP MCB -
2 No 63 AMP DP MCB -
complete panel as above and complete set 1.00 1,03,164.66 1,03,164.66
32.07 MR 9 GIRLS HOSTEL MAIN DISTRIBUTION BOARD -
Design, manufacture, supply, installation, testing and commissioning of cubicle type -
panel fabricated out of CRCA sheet steel , floor mounted totally enclosed switchbaord
suitable for use of 415 volts , 3 phase, 50 HZ complete with aluminium bus bar and
all accessories including supply and fixing of following incoming and outgoing
switchgears, Panel Should Have Double Earthing Provision which connected to the
nearest earth grid.
NOTE:- MCCB's wherever specified upto 250A shall be Thermal Magnetic & Above -
250A will be Microprocessor based inbuilt protections.
INCOMER : 125 AMP FP MCCB -
3 Nos. Phase Indication light (lamp) with MCBs protection.
Multi functional meters (VAF) with suitable CTS and protection MCBS 1 set. -
BUS BAR : 160 AMP, 500 Volts, 3 phase 50 HZ 4P high conductivity electrolytic -
Aluminium bus bar of suitable length, insulated by heat shrinkable sleeves. The
current density of bus bar shall be minimum 0.6 sq mm / amp.
The Maximum allowable temperature for the Bus bar to be restricted to 90 deg C. The -
temperature rise should be restricted to 45 deg C above ambient temperature.
OUT GOINGS : -
14 No 63 AMP FP MCB -
2 No 40 AMP DP MCB -
complete panel as above and complete
32.08 MR 10 TYPE -II ( G+2) STAFF QTRS. METER BOARD ( For 10 Qtrs.)
Digitally signed by VARUN
S. No. Description Unit Quantity Rate Amount (In Rs)
Design, manufacture, supply, installation, testing and commissioning of floor / wall mounted
powder coated cubicle type, totally enclosed dust and vermin proof compartmentalized meter
board fabricated out of 2mm CRCA sheet suitable for use of 415 volts , 3 phase, 50 HZ
complete with bus bars, MV danger notice plate, on surface ISI marked Electronic kWh
meter, indication lamps, CT's, Interconnection with suitable capacity aluminium strips ,
door covers, seperate compartment for each meter, glass inspection window, connection
of incoming and outgoing cables with thimbles, with all accessories including supply
and fixing of following incoming and outgoing switchgears complete as required (Panel Should
Have a common earth bus bar of size 25mmx5 mm at the rear with 2 no. earth stud which is
connected to the nearest earth grid. (Ref :- Fig. 6,CPWD specifications 2023)
NOTE:- MCCB's wherever specified upto 250A shall be Thermal Magnetic & Above 250A
will be Microprocessor based inbuilt protections.
INCOMER : 100AMP FP MCCB, 30 KA with Thermal Release Range (80-100) A with
O/C, S/C protection
3 Nos. Phase Indication light (lamp) with MCBs protection. Multi functional meters (VAF)
with suitable CTs and protection MCBS 1 set.
BUS BAR : 160 AMP, 500 Volts, 3 phase 50 HZ 4P high conductivity electrolytic
extendable type Aluminium bus bar of suitable length, insulated by heat shrinkable sleeves. The
current density of bus bar shall be minimum 0.6 sq mm / amp. The Maximum allowable
temperature for the Bus bar to be restricted to 90 deg C. The temperature rise should be
restricted to 45 deg C above ambient temperature.
12 Nos 40 AMP DP MCB (For each Qtr.DBs and Spare )
10 no. , 5-30 A digital single phase energy ( Kwh) meters of accuracy class 1.0, suitable for -
operation on 240 V, 50 Hz single phase AC supply with polycarbonate body and backlit LCD
display capable of measuring and displaying KWh, V, I, KW, PF, maximum demand in KW
with special features like Tamper logging etc.complete with all necessary wiring.
complete panel as above 1.00 82,863.39 82,863.39
32.09 MR 11 TYPE-III (G+1) 8 nos. STAFF QTRS.METER BOARD
Design, manufacture, supply, installation, testing and commissioning of floor / wall mounted
powder coated cubicle type, totally enclosed dust and vermin proof compartmentalized meter
board fabricated out of 2mm CRCA sheet suitable for use of 415 volts , 3 phase, 50 HZ
complete with bus bars, MV danger notice plate, on surface ISI marked Electronic kWh
meter, indication lamps, CT's, Interconnection with suitable capacity aluminium strips ,
door covers, seperate compartment for each meter, glass inspection window, connection
of incoming and outgoing cables with thimbles, with all accessories including supply
and fixing of following incoming and outgoing switchgears complete as required (Panel Should
Have a common earth bus bar of size 25mmx5 mm at the rear with 2 no. earth stud which is
connected to the nearest earth grid. (Ref :- Fig. 6,CPWD specifications 2023)
NOTE:- MCCB's wherever specified upto 250A shall be Thermal Magnetic & Above 250A
will be Microprocessor based inbuilt protections.
INCOMER : 125 AMP FP MCCB, 30 KA with Thermal Release Range (100-125) A with
O/C, S/C protection
3 Nos. Phase Indication light (lamp) with MCBs protection. Multi functional meters (VAF)
with suitable CTs and protection MCBS 1 set.
BUS BAR : 200 AMP, 500 Volts, 3 phase 50 HZ 4P high conductivity electrolytic
extendable type Aluminium bus bar of suitable length, insulated by heat shrinkable sleeves. The
current density of bus bar shall be minimum 0.6 sq mm / amp. The Maximum allowable
temperature for the Bus bar to be restricted to 90 deg C. The temperature rise should be
restricted to 45 deg C above ambient temperature.
10 Nos 40 AMP DP MCB (For each Qtr.DBs and Spare )
Digitally signed by VARUN
S. No. Description Unit Quantity Rate Amount (In Rs)
8no. , 5-30 A digital single phase energy ( Kwh) meters of accuracy class 1.0, suitable for
operation on 240 V, 50 Hz single phase AC supply with polycarbonate body and backlit LCD
display capable of measuring and displaying KWh, V, I, KW, PF, maximum demand in KW
with special features like Tamper logging etc.complete with all necessary wiring.
complete panel as above 2.00 74,258.88 1,48,517.76
32.10 MR 12 PRINCIPAL QTR., WARDEN RES. ( BOYS AND GIRLS ) METER BOARD -
Design, manufacture, supply, installation, testing and commissioning ofwall mounted powder -
coated cubicle type, totally enclosed dust and vermin proof meter board fabricated out of 2mm
CRCA sheet suitable for use of 230 volts , 1 phase, 50 HZ complete with bus bars, MV
danger notice plate, ISI marked Electronic kWh meter, indication lamps,
Interconnection with glass inspection window, connection of incoming and outgoing
cables with thimbles, with all accessories including supply and fixing of following
incoming and outgoing switchgears complete earthing etc. as required.
INCOMER : 63 AMP DP MCB with 2 nos. LED Indication Lights -
OUT GOINGS : -
1 No 40 AMP DP MCB (For each Qtr.DBs and Spare ) -
1 no. , 5-30 A digital single phase energy ( Kwh) meters of accuracy class 1.0, suitable for -
operation on 240 V, 50 Hz single phase AC supply with polycarbonate body and backlit LCD
display capable of measuring and displaying KWh, V, I, KW, PF, maximum demand in KW
with special features like Tamper logging etc.complete with all necessary wiring.
complete panel as above 3.00 10,225.96 30,677.88
32.11 MR 13 EXTERNAL LIGHT FEEDER PILLAR -
Design, Manufacture, Supply, Installation, Testing and Commissioning of Panel -
Fabricated out of 16 SWG CRCA sheet steel, IP 54, wall / floor mounting type with rain
canopy The sheet steel shall undergo minimum 7 tank treatment followed by finishing powder
coating of min 60 micron thickness. the board includes 415 /240 V electrolitic Aluminium Bus
Bar, removable gland plates, cable glands, including connection with outgoing feeders
complete in all respect, Panel Should Have Double Earthing Provision Which Connected to
the Nearest Earth Grid.
1 no. 100A, 25KA 4P MCCB with Thermal Magnetic based releases, ON indication, + 3 Nos -
63A DP MCB For each Phase.with 3 Nos Astronomical Weekly programmable time switch
(SST- 1min) ON Phase for automaitc switching of landscape light fixtures at sun set and sun
rise or twilight (auto on/ auto off and auto mode) with manual override faiclity with 12/24 hour
display format with suitable battery and indication for relay status i/c programming at site.
TPN Aluminium bus bar with heat Shrink Sleeve rated for 125A.
18 nos 16A DP MCB (For Compound Group Light + Spare)
4 Nos 16KA 40A FP MCCB (Spare) set
1 nos 40A FP MCCB (BORE WELL STAND BY)
Other items such as
1 Set of control wiring
1 Set of designation plates
All Items complete as above 2.00 90,906.36 1,81,812.72
Total of sub-head (32.0) (Non DSR) - 15,44,730.63
33 Supply Of L.T. Cable: -
Supplying of Following Sizes of 1.1 kV Grade Multicore Aluminium Conductor XLPE Power -
Cable Insulated armoured cable conforming to IS:7098 (Part - I) or as per Relevant IS Code
complete with all Amendments etc and should be NABL certified as required.
MR 3.5 C X 300 Sq.mm Al. XLPE arm. Metre 25.00 2,491.70 62,292.50
MR 3.5 C X 185 Sq.mm Al. XLPE arm. Metre 410.00 1,588.79 6,51,403.90
MR 3.5 C X 150 Sq.mm Al. XLPE arm. Metre 15.00 1,255.86 18,837.90
MR 3.5 C X 120 Sq.mm Al. XLPE arm. Metre 340.00 1,069.38 3,63,589.20
MR 3.5 C X 95 Sq.mm Al. XLPE arm. Metre 245.00 871.30 2,13,468.50
MR 3.5 C X 70 Sq.mm Al. XLPE arm. Metre 210.00 696.41 1,46,246.10
MR 3.5 C X 50 Sq.mm Al. XLPE arm. Metre 25.00 515.20 12,880.00
MR 3.5 C X 35 Sq.mm Al. XLPE arm. Metre 20.00 384.55 7,691.00
MR 3.5 C X 25 Sq.mm Al. XLPE arm. Metre 2,340.00 311.86 7,29,752.40
MR 2 C X 16 Sq.mm Al. XLPE arm. Metre 55.00 178.05 9,792.75
MR 2 C X 10 Sq.mm Al. XLPE arm. Metre 165.00 174.89 28,856.85
DSR 7 LT Cable Laying
33.01 DSR 7.1 Laying of One Number PVC Insulated And PVC Sheathed / XLPE Power Cable of 1.1 kV -
Grade of Following Size Direct in Ground Including Excavation, Sand Cushioning, Protective
Covering and Refilling the Trench etc. as required.
DSR 7.1.2 Above 35 sq. mm and upto 95 sq. mm Metre 140.00 405.00 56,700.00
DSR 7.1.3 Above 95 sq. mm and upto 185 sq. mm Metre 250.00 422.00 1,05,500.00
Digitally signed by VARUN
S. No. Description Unit Quantity Rate Amount (In Rs)
33.02 DSR 7.2 Laying of one number additional PVC insulated and PVC sheathed / XLPE power
cable of 1.1 KV grade of following size direct in ground in the same trench in one tier
horizontal formation including excavation, sand cushioning, protective covering and
refilling the trench etc as required.
DSR 7.2.2 Above 35 sq. mm and upto 95 sq. mm Metre 130.00 286.00 37,180.00
DSR 7.2.3 Above 95 sq. mm and upto 185 sq. mm Metre 250.00 304.00 76,000.00
33.03 DSR 7.3 Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade
of following size direct in ground including excavation and refilling the trench etc as required.
but excluding sand cushioning and protective covering.
DSR7.3.2 Above 35 sq. mm and upto 95 sq. mm Metre 130.00 217.00 28,210.00
DSR 7.3.3 Above 95 sq. mm and upto 185 sq. mm Metre 200.00 234.00 46,800.00
33.04 DSR 7.5 Laying of one number PVC insulated & PVC sheathed/ XLPE Power cable of 1.1 KV grade of
following size in the existing RCC/HUME/METAL pipe as required.
DSR 7.5.2 Above 35 sq. mm and upto 95 sq. mm Metre 35.00 57.00 1,995.00
DSR 7.5.3 Above 95 sq. mm and upto 185 sq. mm Metre 25.00 77.00 1,925.00
33.05 DSR 7.7 Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1
KV grade of following size on wall surface as required.
DSR 7.7.1 Upto 35 sq. mm (clamped with 1mm thick saddle) Metre 40.00 55.00 2,200.00
DSR 7.7.3 Above 35 sq. mm and upto 95 sq. mm (clamped with 25x3mm MS flat clamp) Metre 10.00 130.00 1,300.00
DSR 7.7.3 Above 95 sq. mm and upto 185 sq. mm (clamped with Metre 15.00
25/40x3mm MS flat clamp)
33.06 DSR 7.6 Laying of one number PVC insulated & PVC sheathed/ XLPE Power cable of 1.1 KV grade of
following size in the existing masonary open duct as required.
DSR 7.6.2 Above 35 sq. mm and upto 95 sq. mm Metre 35.00 45.00 1,575.00
DSR 7.6.3 Above 95 sq. mm and upto 185 sq. mm Metre 25.00 63.00 1,575.00
DSR 7.6.4 Above 185 sq. mm and upto 400 sq. mm Metre 25.00 115.00 2,875.00
DSR 9 LT CABLE JOINTING & END TERMINATION -
33.07 DSR 9.1 Supplying and Making End Termination With Brass Compression Gland and Aluminium lugs -
for Following Size of PVC Insulated and PVC Sheathed / XLPE Aluminium Conductor Cable
of 1.1 kV Grade as Required.
Total of sub-head (33.0) (Non DSR) - 22,44,811.10
Total of sub-head (33.0) (DSR) - 10,06,616.00
34.0 HT Cable And Accessories -
34.01 MR 18 Supply of H.T. Cable -
Supply & Testing of following 11 KV( UE) grade multicore Aluminium conductor XLPE -
insulated cable, insulation screening with extruded semi conducting compound in combination
with copper tape armoured cores laid up, inner sheath of PVC tape, galvanised steel flat strip
armoured and overall PVC sheathed cable conforming to IS: 7098 (Part - II) and complete with
all latest amendments etc. complete as required.
34.02 DSR 8 H.T. Cable Laying-DSR Item -
H V CABLE LAYING -
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 11 KV -
grade of size upto 120 sq.mm. as under :-
DSR 8.1.1 (a) direct in ground including excavation, sand cushioning, protective covering and Metre 50.00
refilling the trench etc as required.
DSR 8.2.1 (b)direct in ground in the same trench in one tier horizontal formation including Metre -
excavation, sand cushioning, protective covering and refilling the trench etc as 362.00 -
DSR 8.3.1 (c) in the existing RCC/HUME/METAL pipe as required. Metre 10.00 77.00 770.00
DSR 8.4.1 (d) in the existing masonary open duct as required. Metre 20.00 63.00 1,260.00
DSR 10.1 H.T Termination: DSR Item - -
Digitally signed by VARUN
S. No. Description Unit Quantity Rate Amount (In Rs)
34.03 DSR 10.1 Supply and making Indoor cable end jointing with cast resin compund, including lugs and other
jointing materials for following size of 3 core, XLPE aluminium conductor cable of 11KV - -
(UE) grade as required.
34.04 DSR 10.2 Supply and making Outdoor cable end jointing with cast resin compund, including lugs and
other jointing materials for following size of 3 core, XLPE aluminium conductor cable of - -
11KV ( UE )grade as required.
Total of sub-head (34.0) (Non DSR) 1,01,985.60
Total of sub-head (34.0) (DSR) - 39,274.00
35.0 DSR 2 Miscellaneous Items - DSR -
35.01 2.21 Providing and fixing M.V. danger notice plate of 200 mm X 150 mm, made of mild steel, at Nos. 12.00
least 2 mm thick, and vitreous enameled white on both sides, and with inscription in single red 269.00 3,228.00
colour on front side as required.
35.02 2.22 Providing and fixing H.T. danger notice plate of 250 mm X 200 mm, made of mild steel, at Nos. 2.00
least 2 mm thick, and vitreous enameled white on both sides, and with inscription in single Red 292.00 584.00
colour on front side as required.
35.03 7.90 Supplying and making cable route marker with cement concrete 1:2:4 (1 cement : 2 coarse sand Each 5.00
: 4 graded stone aggregate 20 mm nominal size ) of size 60 cm X 60 cm at the bottom and 50
cm X 50 cm at the top with a thickness of 10cm including inscription duly engraved as required. 585.00 2,925.00
35.04 7.10 Supplying and fixing cable route marker with 10 cm X 10 cm X 5 mm thick G.I. plate with Each 5.00
inscription there on, bolted /welded to 35 mm X 35 mm X 6 mm angle iron, 60 cm long and 508.00 2,540.00
fixing the same in ground as required.
Miscellaneous Items - MR Items -
35.05 MR 19 SITC of shock treatment chart (prescribed under I.E.rules) duly framed with glass and Nos. 2.00
supported from back with hard board with supply of all material labour T & P etc for proper 474.11 948.22
completion of work. (Approx front area = 1.20 sq M)
35.06 MR 20 SITC of First aid box as approved by Indian red cross conforming to IS : 2217. Nos. 2.00 348.73 697.46
35.07 MR 21 SITC of Fire Bucket stand made of M S angle suitable for and with 4 Nos Fire Buckets of 9.5 Set 2.00
Ltrs capacity filled with
35.08 MR 22 SITC of of rubber gloves of 11 KV grade as per IS : 4770. Set 2.00 446.71 893.42
35.09 MR 23 Supplying and fixing of high voltage insulation mat of class B having 11 KV dielectric Metre 1.00
strength, 1000mm width and thickness of 2.5mm ISI approved as required including cutting to 3,845.54 3,845.54
required lengths.
35.10 MR 24 Supplying and fixing of high voltage insulation mat of class B having 1.1 KV dielectric Metre 3.00
strength, 1000mm width and thickness of 2.0 mm ISI approved as required including cutting to 2,582.30 7,746.90
required lengths.
Total of sub-head (35.0) (DSR) - 9,277.00
Total of sub-head (35.0) (Non DSR) - 20,969.22
36.0 DSR 5 Earthing -
36.01 5.4 Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and Set 18.00
providing masonry enclosure with cover plate having locking arrangement and watering pipe of 7,472.00 1,34,496.00
2.7 meter long etc. with charcoal/ coke and salt as required.. (For BODY EARTHING of
36.02 5.6 each Electrical
Earthing Panelsearth
with copper & Generator Neutral
plate 600 mm X 600& mm
3 mm thick including accessories, and Set 4.00
providing masonry enclosure with cover plate having locking arrangement and watering pipe of 13,838.00 55,352.00
2.7 meter long etc. with charcoal/ coke and salt as required.. ( For Transformer BODY &
36.03 5.2 Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing SET 4.00
masonry enclosure with cover plate having locking arrangement and watering pipe etc. with
charcoal/ coke and salt as required 6,855.00 27,420.00
36.04 5.15 Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as Metre 215.00
36.05 5.18 Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing along with Metre 7,720.00
existing surface/ recessed conduit/ submain wiring/ cable as required.
36.06 5.14 Providing and fixing 25 mm X 5 mm copper strip on surface or in recess for connections etc. as Metre 40.00
36.07 5.12 Providing and laying earth connection from earth electrode with 6 SWG dia G.I. Wire in 15 Metre 20.00
mm dia G.I. pipe from earth electrode including connection with G.I. thimble excavation and re- 287.00 5,740.00
filling as required.
Total of sub-head (36.0) (DSR) 6,46,188.00
37.0 DSR 11 Pole Erection -
37.01 11.3 Erection of metallic pole of following length in cement concrete 1:3:6 (1 cement : 3 coarse sand -
: 6 graded stone aggregate 40 mm nominal size) foundation including excavation and refilling
etc. as required.
11.3.1 Above 4.5 metre and upto 6.5 metre Each 45.00 5,121.00 2,30,445.00
37.02 11.6 Supplying and embedding following dia G.I. pipe (medium class) in pole collar/ foundation
(during casting) for cable entry including bending the pipe to the required shape , Hole Seeling - -
to be done complete as required.
Digitally signed by VARUN
S. No. Description Unit Quantity Rate Amount (In Rs)
Total of sub-head (37.0) (DSR) 3,48,570.00
38.0 External Lighting System -
38.01 MR 26 Supply , Installation, Testing & Commissioning of Integrated Post Top Lantern With Nos. 2.00
45W LED Lamp including suitable size dia G.I.Pipe Pole i/c connection with 3 x 2.5
sq.mm single core PVC insulated copper conductor cable from junction box to fixture
as required. 4,714.73 9,429.46
38.02 MR 27 Supply , Installation, Testing & Commissioning of 60 W LED with complete with pot Nos. 34.00
optic reflector i/c connection with 3x2.5sq.mm single core PVC insulated copper
conductor cable from junction box to fixture as required 3,451.50 1,17,351.00
38.03 MR 28 SITC of Hybrid All In One Integrated Solar LED Street Light fitting rated for 40W Nos. 14.00
output with integrated solar laminate of 80 Wp ( or more) based on Mono crystalline
cell technology, along with battery of rating 12.8V 30Ah (or more) based on Lithium
Ferro Phosphate Chemistry (LiFePO4), with a light output of greater than 6000
Lumens (>6000), LEDs with a life greater than >50000Hrs and Lumen efficacy greater
than 150Lm/W , with an autonomy of 2 days ( 24 hrs.)or more with dimming, INBUILT
PROTECTIONS FOR LONGER RELIABILITY - Over Charge Protection, Deep 45,092.86 6,31,300.04
Discharge Protection, Battery Reverse Polarity Protection, Load Short Circuit
Protection, Load Open Circuit Protection, Reverse Polarity Protection for Panel and
Over Temperature Protection. Surge Protection for Hybrid Models. The housing of the
street light should be made of Extruded Aluminium / Die Cast Aluminium, equipped
with battery charge controller of efficiency greater than 92%, hybrid controller
(efficiency of greatercertificates/documents
B )The following than 85% and motion detection sensor with
are mandatory atleast
at the time 12mtr range.
after execution as and where applicable :- 1. EN50530 – MPPT Efficiency
4. IEC 60598 – Part 1 – General requirement
6. LM 79 REPORT
The Executant must submit the TDS, LM 79 report , IK 08 & IP 65 report of third party
NABL lab , LM80 report of chip manufacturer in the department for obtaining the
approval from the authority prior to start of work/ procurement of Solar street lights. - -
Reports of inhouse lighting company Lab having NABL accrediation will not be
Test reports like EN50530 – MPPT Efficiency , IEC61547 ,IEC61000-3-2 – EMC , IEC
60598 – Part 1 – General requirement , IEC 62109 obtained from Third party NABL
Lab/ TUV/UL/MNRE Lab's test report are required to be submitted by the executant
along with manufacturer's warranty certificate in the name of concerned department
for providing 5 years complete system warranty & providing immediate after sales
service within the warranty period against manufacturing defects, LM 79 report,IP 65
report , IK 08 report against the supply of Hybrid AIO Solar lights for it's acceptance
by the department
38.04 MR 29 Building Outer Light (60W LED) :- Supply, fitting, fixing and testing of building outer Each 7.00
lighting luminaire aerodynamically shaped single piece pressure die-cast Aluminum
luminaire with high power LEDs as light source and electronic driver (IP66), along with
60W LED Lamp as Energy saving as per drawing prescribed reflector and heat
resistant toughened flat glass cover, with 5ft long 40mm dia G.I. pipe with 3 Nos. of
iron clamps , anchor nut bolts with double washers as per direction of E/I or consultant
as per drawing prescribed reflector and heat resistant toughened flat glass cover. 5,299.46 37,096.22
(Make:- Philips/Trilux/Hevells-Endura Pearl Neo/Wipro.
38.05 MR 30 Supply, Installation, Testing and Commissioning of 200x160x98 (KVPC) Nos. 7.00
Polycarbonate thermoplastics enclosure - junction box with I.P - 65 Protection with
Terminals & cable hinged cover of approved design complete having gasket of
internally embedded & made of polyeutherene & should be weather proof, rust proof,
dust proof, water proof - box shall be tested as per IEC - 60670-2/60670-22. the box
shall have self threaded holes & provision for mounting din rail. with 2 Nos cable gland
including supplying & fixing crimping 2 nos lugs & 1 nos 32A connector 6 way for
looping the incoming & outgoing cables and also connection of the street light one 6A
SP MCB Including Connection of 2x6 sqmm Cable etc as Required.
Digitally signed by VARUN
S. No. Description Unit Quantity Rate Amount (In Rs)
38.06 MR 31 Supply and fixing of GI/MS swaged round/octagonal tubular pole of 6 Metre length 45.00
(Above Ground) with Top-70 mm, bottom-135 mm, Base Plate 220x220x12 mm, PCD-
205 mm, Foundation Bolts-M20X600, suitable for single/double arm bracket for Solar/
LED fitting. The pole shall be provided with suitable base plate arrangement for fixing
on pedestal and looping box complete with MCB, brass connectors etc complete i/c
making c.c.foundation as required. The street lighting pole shall be in accordance with 6,552.16 2,94,847.20
38.07 MR 32 Supplying/fixing of following light pole arm Bracket fabricated out of GI pipe having -
thickness and length as per manufacturer design complete etc as reqd.
a Single arm bracket 28.00 767.00 21,476.00
b Double arm bracket 3.00 1,325.39 3,976.17
38.08 Supplying of Following sizes 1100 volt grade XLPE insulated PVC sheathed
aluminium conductor armoured cables as per specification in existing laid in ground
38.09 Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1
kV grade of size up to 35 sq. mm
7.3.1 ( a ) direct in ground including excavation and refilling the trench etc. as required, but Metre 2,550.00
excluding sand cushioning and protective covering.
38.10 7.5.1 Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1
kV grade of following size in the existing RCC/ HUME/ METAL pipe as required. - -
38.11 14.15.1 Supplying and laying of following size DWC HDPE pipe ISI marked along with all
accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete - -
diaand cutting,
(OD-63 mmjointing
the existing trench, complete as required. Metre 100.00
38.12 5.18 Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing Metre 2,880.00
along with existing surface/ recessed conduit/ submain wiring/ cable as required.
Total of sub-head (38.0) (DSR) 6,63,585.00
Total of sub-head (38.0) (Non DSR) - 15,33,216.11
39.0 10KVA Online UPS 3PH input/ 3PH output -
0.01 MR 34 Supply of 10 kVA Online UPS, IGBT UPS (Transformer-less Design). -
Supply of SMF Batteries (12Volt VRLA, 26 Ah, 40 Numbers or as per standard Nos to -
provide 30 Minutes Backup in total for 10 kVA UPS at 0.8PF and ECV=1.7V.
Fully rated Inbuilt static switch at the inverter output and 100% rated Inbuilt static switch at the -
static bypass line integrated in UPS module.
Supply of Local Accessories (like Cabling Between UPS and the Battery onsidering Cable -
Routing ,Battery Interlinks ,Battery Rack etc).
Backfeed protection at Mains & Bypass (Inbuilt / External). -
Installation and Commissioning of 10 kVA UPS, Battery and Accessories. set 1.00 2,29,893.50 2,29,893.50
39.01 MR 35 Supply , installation , testing and commissioning 63A FP MCB of 10kA breaking Capacity in set 2.00
metal sheet enclosure with ON/OFF, TYB Indication lamps for Incoming of UPS Complete in 3,607.43 7,214.86
All Respect as Required.
Total of sub-head (39.0) (Non DSR) 2,37,108.36
40.0 MR 36 Lightening Arrester System For Transformer
Supply, Installation, Testing & Commissioning of Lightening Arrester HT-12 kV expulsion Each 3.00
type complete with all Fitting transission class discharge capacity 10 kA complete all as as 4,180.57 12,541.71
Total of sub-head (40.0) (Non DSR) 12,541.71
41.0 Pumps (Non Scheduled Items)
41.01 MR Borewell Submersible Pump Set 2.00 57,810.52 1,15,621.04
Supplying & Installation of suitable borewell submersible pump set coupled with 6" motor and -
complete with lowering in existing borewell with the help of chain pulley block including
supplying and fixing motor starter suitable for the selected pump complete as required.( Note :
The suction/delievery pipe lines are not included in this item )
Flow Rate : 350 to 400 LPM
min. Head : 60 M
Digitally signed by VARUN
S. No. Description Unit Quantity Rate Amount (In Rs)
Min. Motor HP : 7.5 H.P.
41.02 MR Supplying and Fixing of PVC covered 6 mm dia flexible steel rope for handling/protecting the Metre 300.00
submersible Pump set including U-lock arrangement etc. complete as required.
41.03 MR Supplying and Fixing of suitable size of MS clamp set suitable for holding submersible pump Each 4.00
& 40 mm dia pipe assembly lowered in bore well including suitable drilled hole and nut bolts
etc. complete as required. 770.16 3,080.64
41.04 MR Supplying and Fixing of following size of PVC insulated PVC sheathed Copper conductor flat
submersible cable including fixing the cable with nylon tie along with GI pipes in existing
borewell, connection with submersible pump cable with the help of water proof jointing kit
provided with the pump, complete as required.
S/Fixing of 8 " dia MS cover with locking arrangement i/c drilling hole and s/f nut bolts etc. 2.00
complete as reqd. 1,087.29 2,174.58
41.05 MR Openwell Submersible Monobloc Pump Set Set 2.00 53,450.84 1,06,901.68
S.I.T.C. of 7.5/5.5 (H.P./Kw) Openwell Submersible Monobloc Pump Set comprising of -
Electrical Driven inline pumping with all accessories as per manufacturer's design. such as C.I.
Base, S.S /bronze impeller, shaft, mechanical seal, S.S. Shaft directly coupled to motor suitable
for operation on 400/440 volts, 3 phase 50c/s A.C.Supply complete in the existing
G.I.Pipelines fittingsi/c s/fixing motor starter suitable for this pump set i/c connections testing,
commissing etc as reqd. ( Note : The suction/delievery pipe lines are not included in this
Flow Rate : 4.5 to 5.0 LPS -
Min. Head : 50 M -
Min. Motor HP : 7.5 H.P. (Each) -
Total of sub-head (41.0) (Non DSR) 2,63,651.94
42 CCTV SYSTEM
42.01 1.53 Supplying and drawing of UTP 4 pair CAT 6 LAN Cable in the existing surface/ recessed
Steel/ PVC conduit as required.
42.02 1.21 Supply and fixing of following sizes of medium class PVC conduit along with accessories in
surface/recess including cutting the wall and making good the same in case of recessed conduit - -
42.03 MR36 1/2.8" Progressive Scan CMOS, PAL:1920 * 1080, 0.1 Lux/ F1.2 (0Lux, IR ON), 10~15 Each 11.00
Meters (With Min. 24 units IR LED), 2 MP Fixed IR DOME CAMERA With Options Of
2.8mm , 4mm , 6mm Lens , IP66 , POE with installation.
42.04 MR37 1/2.8" Progressive Scan CMOS, PAL:1920 * 1080, 0.1 Lux/ F1.2 (0Lux, IR ON), 10~15 Each 20.00
Meters (With Min. 24 units IR LED), 2 MP Fixed IR Bullet CAMERA With Options Of
2.8mm , 4mm , 6mm Lens , IP66 , POE with installation. 6,835.57 1,36,711.40
42.05 MR38 Supplying, installation, fixing, testing and commissioning of 16 ch Linux, H. 264 / H.265 NVR Each 4.00
with Minimum 1080p / UXGA / 720p / VGA / 4CIF / DCIF / 2CIF / CIF / QCIF rec.
resolutions, 4 HDD slot supports upto 4 TB Each, RS 485 x 1 & USB2.0 x1, HDMI ,Local
And Remote Access Over Internet In complete in all respect with installation (Make: - CP 29,935.13 1,19,740.52
PLUS , Dahua ,Hikvision or equivalent )
42.06 MR39 4 TB Surveillance Sata HDD (WD Purple , Seagate Surveillance or Equivalant) Each 1.00 11,089.89 11,089.89
42.07 MR40 16 Port POE Switch (Cisco , Netgear , Dlink or Equivalant) Each 1.00 18,665.07 18,665.07
Digitally signed by VARUN
S. No. Description Unit Quantity Rate Amount (In Rs)
42.08 MR41 Supply, installation, testing and commissioning of Independent 1 kVA UPS system with 230V Each 3.00
single phase input and 230V Single phase output with all required accessories & battery bank
for 30 mins back up with covered SMF battery and battery rack for all new required loads
covered as required, including connections as per specifications etc. complete as required.
42.09 MR42 S.I.T.C.32" Color flat panel LED Monitor,Full HD Professional Series 1920 x 1080 resolution, Each 4.00
inputs. 100-230VAC/50 Hz.
Total of sub-head (42.0) (DSR) 1,56,385.00
Total of sub-head (42.0) (Non DSR) 5,44,370.83
43 LIGHTNING CONDUCTOR
43.01 6.2 Providing and fixing of lightning conductor finial, made of 25mm dia 300mm long, G.I tube, Each 36.00
having single prong at top with 85mm dia 6mm thick G.I base plate including holes etc. 518.00 18,648.00
complete as required.
43.02 6.7 Providing and fixing G.I tape 20 mm x 3 mm thick on parapet or surface of wall for lightning Mtrs. 1,250.00
conductor complete as required. (for horizontal run )
43.03 6.8 Providing and fixing G.I tape 20 mm x 3 mm thick on parapet or surface of wall for lightning Mtrs. 275.00
conductor complete as required. (for vertical run )
43.04 6.4 Jointing copper / G.I. tape (with another copper/ G I tape, base of the finial or any other Each 86.00
metallic object) by riveting / nut bolting/ sweating and soldering etc as required.
43.05 6.12 Providing and fixing testing joint, made of 20 mm X 3 mm thick G.I. strip, 125 mm long, with Each 16.00
4 nos. of G.I. bolts, nuts, chuck nuts and spring washers etc. complete as required.
43.06 5.4 Earthing with G.I. earth plate 600mm x 600mm x 6mm thick including accessories, and Set. 16.00
providing masonary enclosure with cover plate having locking arrangement and watering pipe
of 2.7Mtr long etc. with charcoal/ coke and salt as required.
Total of sub-head (43.0) (DSR) - 3,61,529.00
44 D.G.Set and associated works
44.01 A D.G.Set 25 KVA
Providing, Installing, Testing and Commissioning of ‘Silent Type’ Diesel Generating set
alongwith having Prime Power Rating of 25 KVA, 415 volts at 1500 RPM, 0.8 lagging power
factor at 415 V suitable for 50 Hz, 3 phase system & for 0.85 Load Factor and consisting of the
(a) Diesel Engine:
Diesel engine 4 stroke water cooled, electric start, of suitable BHP at 1500 RPM suitable for
above output of alternator at 40 Degree C, 50% RH & at 1000 Meter MSL and conforming to
BS 5514, BS 649, IS 10000, capable of taking 10% over loading for one hour after 12 hours of
continuous operation. The engine will be fitted complete with all the required accessories.
(b) Engine mounted Instrument Panel fitted with and having digital display for following:
(i) Start-stop switch with key
(ii) Water temperature indication
(iii) Lubrication oil pressure indication
(iv) Lubrication oil temperature indication
(v) Battery charging indication
(vi) RPM indication
(vii) Over speed indication
(viii) Low lub. Oil trip indication
(ix) Engine Hours indication
(c) Alternator :
Synchronous alternator rated at 25 KVA, 415 volts at 1500 RPM, 3 phase 50 Hz, AC supply
with 0.8 lagging power factor at 40 Degree C, 50% RH & at 1000 Meter MSL. The alternator
shall be having SPDP enclosure, brushless, continuous duty, self-excited and self-regulated
through AVR conforming to IS: 4722/BS 2613 suitable for tropical conditions and with class-
(d) Base Frame & Foundation:
Both the engine and alternator shall be mounted on suitable base frame made of MS channel
with necessary reinforcement which shall be installed on suitable cement concrete foundation
and vibration isolation arrangement as per recommendations of manufacturer.
(e) Fuel Tank:
Daily service fuel tank of minimum 60 liters capacity fabricated out of 3 mm thick M.S. sheet
complete with all standard accessories and fuel piping between fuel tank and diesel engine
with MS class ‘C’ pipes of suitable dia. Complete with valves, level indications & accessories as
required as per specifications OR as per recommendations of manufacturer.
(f) Exhaust System:
Dry exhaust mainfold with hospital exhaust silencer and catalytic convertor.
Digitally signed by VARUN
S. No. Description Unit Quantity Rate Amount (In Rs)
(g) Starting System:
12V/24V DC starting system comprising of starter motors: voltage regulator and
arrangement for initial excitation complete with suitable nos. of batteries (25 plates, 180 Amp.
Hour capacity lead acid type) as required as per specifications.OR as per recommendations of
(h) Accoustic and weather proof enclosure with arrangement for fresh air intake for cooling of the
engine & alternator, extraction, discharging hot air in to the atmosphere as per specifications &
Engine & Alternator stands warranty for minimum period of 24 months or 5000 hours of
operation whichever earlier
B AMF system for 25 KVA DG Set Part of DG.
Fabricating, Installing, Testing & Commissioning of automatic mains failure control including
auto by-pass panel, suitable for 25 KVA silent type DG set complete with relays, timers, set of
CTs for metering & protection and energy analyser to indicate currents, phase and line
voltages, frequency, power factor, KWH, KVARH & provision for overload, short circuit,
restricted earth fault, under frequency, control cabling from AMF panel to diesel engine and
elsewhere if required, all complete and inter locking including the following:
(a) (i) 1 No. 63 415V, 4P MCCB of 35kA.
(ii) 2 Nos. 63 A, 415V 4P Contactor
(b) Auto/Manual/Test/Off selector switch
(c) 2 Nos over voltage relay, 2 Nos reverse power relay and 2 Nos under voltage relay.
(d) 3 Sets of current transformers 15 P 10 accuracy for protection and 15 VA class-I for metering
(e) Energy analyser unit to indicate current voltage frequency power factor and KWH
(f) Indicating lamps for load on mains and load on set
(g) Fuse for instruments
(h) Battery charger, complete with transformer/ rectifier, D.C. voltmeter and ammeter, selector
switch for trickle, off and boost and current adjustment.
(i) Main supply failure monitor
(j) Supply failure timer
(k) Restoration timer
(l) Control unit with three impulse automatic engine start/stop and failure to start lockout.
(m) Impulse counter with locking and reset facility.
(n) ON/OFF/Control circuit switch with indicator
(o) Audio/Video annunciation for
(i) High water temperature
(ii) Low lubricating oil pressure
(iii) Engine over speed
(iv) Engine fails to start 1.00 5,85,539.18 5,85,539.18
(v) Full load/maximum load warning
44.02 MR Supplying and fixing exhaust gas piping of 75mm dia. welded black MS, B Class pipe 4.00
conforming to IS:3589 cut to required lengths and installed with necessary bends, supports and
clamps, anti-vibration mountings, insulation of exhaust system with mineral wool/Rockwool, 1,348.57 5,394.28
50 mm thick wiremesh & aluminum cladding etc., as required as per specifications.
Total of sub-head (44.0) (Non DSR) 5,90,933.46
Digitally signed by VARUN
Construction of Eklavya Model Residential School (EMRS)” at Darbha, District- Bastar Chhattisgarh
ABSTRACT OF COST (Kitchen Machinery)
S. No. COD Description of works SIZE Quantity Sample Image Rate i/c GST@18% Amount
1 01 SITC of SS One Burner STOCK POT RANGE Comprising: 3 Nos. 14,750.00 44,250.00
16Ga. SS 304 GR Top,
Body 20 Ga. 304 GR SS,
1 no. 400mm x 400mm Cast iron pan support,
1 no. burner with pilot lamp,
1 no. 20 Ga. SS drip tray with handle,
38mm SQ 16 Ga. SS pipe legs. With adjustable bullet feet.
100mm setback Body/legs for Gas pipe routing.
2 02 SITC of SS 2 BURNER INDIAN COOKING RANGE Comprising: 1 No. 28,910.00 28,910.00
16Ga. SS 304 GR Top,
Body 20 Ga. 304 GR SS,
2 no. 400mm x 400mm Cast iron pan support,
2 no. burner with pilot lamp,
2 no. 20 Ga. SS drip tray with handle,
38mm SQ 16 Ga. SS pipe legs. With adjustable bullet feet.
100mm setback Body/legs for Gas pipe routing.
3 03 SITC of SS SINGLE SINK UNIT Comprising: 1 No. 15,045.00 15,045.00
16 Ga. SS 304 GR Top, 150mm High Rear splash,
Top provided with One (1) no. 450mm x 450mm x 250mm deep of 16 Ga. S.S. 304 GR Sink Complete
with 50mm dia lever handle operated waste outlet, 38mm SQ 16 Ga. SS legs. With adjustable feet. With 24 X 24 X 34+6
three side cross bracing. (inches)
4 04 SITC of SS TILTING TYPE BULK COOKER Comprising: 1 No. 1,03,250.00 1,03,250.00
Inner Cell of bottom 4 mm & side wall 1.5 mm thick Stainless Steel 304 grade, Outer wall- made of 18 GA
SS 304 grade, Lid - 18 GA SS 304 grade with Heavy Duty Spring loaded for Easy open & close with SS
Handle, Panels - made of 20 GA SS 304 grade,
Stand - SS Pipe 50mm x 50mm,16GA.
Tilting arrangement - On wheel with Gear arrangement and Interlock Brake.
For Water - One Swivel Type Sink Cock fitted with SS pipe Long Nipple to Connect Existing Water Point. 200 LTRS (Capacity)
1 no. burner with pilot lamp.
5 05 SITC of SS TILTING TYPE BOILING PAN Comprising: 1 No. 98,530.00 98,530.00
Inner Cell of bottom 4 mm & side wall 3 mm Stainless Steel 304 grade, Outer wall- made of 18 GA SS 304
grade, Lid - 18 GA SS 304 grade with Heavy Duty Spring loaded for Easy open & close with SS Handle,
Panels - made of 20 GA SS 304 grade,
Stand - SS Pipe 50mm x 50mm,16GA.
Tilting arrangement - On wheel with Gear arrangement and Interlock Brake.
For Water - One Swivel Type Sink Cock fitted with SS pipe Long Nipple to Connect Existing Water Point. 200 LTRS (Capacity)
3 no. “RV” type burner with pilot lamp
Digitally signed by VARUN
Construction of Eklavya Model Residential School (EMRS)” at Darbha, District- Bastar Chhattisgarh
ABSTRACT OF COST (Kitchen Machinery)
S. No. COD Description of works SIZE Quantity Sample Image Rate i/c GST@18% Amount
6 06 SITC of SS SPICE TROLLY Comprising: 2 No. 14,160.00 28,320.00
16 Ga.304 SS Top all side turned up 50mm,
Two (2) no Full width 18 Ga. SS 304 grade Bottom shelves.Four (4) no. 100mm dia uprights on Castors. 18 X 24 X 34
7 07 SITC of SS WORK TABLE WITH 1 Bottom Shelf Comprising: 4 No. 14,750.00 59,000.00
16 Ga. 304 SS Top. All sides turned down 50mm & in 12mm.
18 Ga. SS 304 Bottom shelves. 44 X 24 X 34
Four (04) no. 38mm sq SS legs. With adjustable bullet feet. (inches)
8 08 SITC of CHAPATI HOT PLATE Comprising: 2 No. 46,020.00 92,040.00
Full 12 mm thick MS Plate with LHS puffer plate,
Exterior 20 Ga. SS 304 cladding,
Built-in pressure Controller regulator,
38mm SQ 16 Ga. SS pipe legs with adjustablebullet feet,
Four (4) no. “RV” type burner with pilot lamp
9 09 SITC of SEMI AUTOMATIC CHAPATI MAKING MACHINE Comprising: Gas operated, with all gas 1 No. 3,24,759.18 3,24,759.18
fiitings, burners and necessary electric motor of rating 0.75 KW, 220V ISI mark all complete.
10 10 SITC of CONVEYOR TYPE TOASTER Comprising: SS 20 GA body with necessary electrical motor and 2 Nos. 42,244.00 84,488.00
heating element of Power : 1.5 kw, 220V etc with timer controllar all complete ISI marks.
120-150Pcs /Hrs
11 11 SITC of SS 4 DOOR VERTICAL CHILLER Comprising: 2 Nos. 1,38,355.00 2,76,710.00
Exterior/Interior wall of 20 Ga. 304 grade SS cladding, Internal temp range from 0 Deg to + 4 Deg Celsius,
With doors 20 GA Inside and 18 GA. 304 grade SS outside Four (4) Nos. half size Insulated self closing
type SS doors, complete with handle, gasket, Compressor (Emerson or equivalent make) & Controls 1
KW-220 V AC with adjustable bullet feet. 48 X 28 X 78
(inches) 900 LTRS
12 12 SITC of DEEP FREEZER: 1 No. 46,020.00 46,020.00
50mm thick PU foam on all sides with plastric material body. Brand - Voltas or equivalent rating 1 KW
220 V AC all complete as per manufacturer specifications 500 LTRS
13 14 SITC of DRY MASALA GRINDER Comprising: SS Jar of Capacity 5 kg, with electric motor of Power 1 No. 21,476.00 21,476.00
rating : 1/2 Hp, 220V of ISI mark all complete as per manufacturers specification .
5 KG (Capacity)
Digitally signed by VARUN
Construction of Eklavya Model Residential School (EMRS)” at Darbha, District- Bastar Chhattisgarh
ABSTRACT OF COST (Kitchen Machinery)
S. No. COD Description of works SIZE Quantity Sample Image Rate i/c GST@18% Amount
14 15 SITC of PULVERISER Comprising: 20 GA SS body, electrically operated with electric motor of Power : 1 No. 19,765.00 19,765.00
2 HP, 220V of ISI mark, etc all complete as per manufacturer specifications.
15 16 SITC of DOUGH KNEADER- Comprising: 16 GA bowl of SS and 20 GA SS body, electrically operated 1 No. 67,260.00 67,260.00
with motor of Power : 2 HP, 220V of ISI mark, etc all complete as per manufacturer specifications.
16 18 SITC of SS 6 VESSEL HOT BAIN MARIE WITH 1/1 Gastro-Norm PAN WITH FRONT TRAY RAIL 2 Nos. 66,670.00 1,33,340.00
Comprising: 16 Ga. SS 304 Grade Top,
1No tank 16 Ga.304 SS grade Bain Marie complete with water outlet, 4.0 k.w. heating element, 6 no.
Gastro-Norm 1/1 Pan, 150mm deep with lid,
Front Pipe Trai Rail, Full length 18 Ga. SS 304 grade Bottom shelve,
Electrical panel complete with thermostat, on-off switch & light indicator with 4 No. 38mm sq. pipe 16
GA SS legs with adjustable bullet feet, all complete.
17 18A SITC of SS 6 VESSEL HOT BAIN MARIE WITH 1/1 Gastro-Norm PAN WITH FRONT TRAY RAIL 2 Nos. 65,490.00 1,30,980.00
Comprising: 16 Ga. SS 304 Grade Top, 6 no. Gastro-Norm 1/1 Pan, 150mm deep with lid, Front Pipe Trai
Rail, Full length 18 Ga. SS 304 grade Bottom shelve, with 4 No. 38mm sq. pipe 16 GA SS legs with
adjustable bullet feet,all compelete. 84 X 26+12 X 34
18 19 SITC of PLATFROM TROLLY Comprising: 16 GA 25 mm dia SS 304 grade pipe pulling/pushing 2 Nos. 18,585.00 37,170.00
arrangement, 16 GA.304 SS platform Top all side turned down 50mm, Four (4) no. 100mm dia uprights on
19 20 SITC of KITCHEN UTILITY TROLLY Comprising: 16 GA 25 mm dia SS 304 grade pipe 3 Nos. 20,355.00 61,065.00
pulling/pushing arrangement, 16 GA.304 grade SS top all side turned up 50mm, Two (2) no Full width 18
Ga. SS 304 grade Bottom shelves with Four (4) no. 100mm dia uprights on Castors all complete.
20 21 SITC of SS POT RACK - 4 SHELF Comprising: Four (4) nos 20mm x 20mm x 16 Ga. SS squre pipe 2 Nos. 36,580.00 73,160.00
Grade 304 SS Shelves welded to SS square pipe uprights with 38mm x 38mm x 16GA 304 grade SS
squre pipe, upright with adjustable bullet feet all complete.
Digitally signed by VARUN
Construction of Eklavya Model Residential School (EMRS)” at Darbha, District- Bastar Chhattisgarh
ABSTRACT OF COST (Kitchen Machinery)
S. No. COD Description of works SIZE Quantity Sample Image Rate i/c GST@18% Amount
21 22 SITC of SS STORAGE RACK - 4 SHELF Comprising: 18 Ga. 304 grade SS Shelves four (4) nos with 6 Nos. 17,700.00 1,06,200.00
frame of four nos. vertical angles size 38 x38x 3 mm of SS grade 304 all complete.
22 23 Supplying of HDPE PALLET of capacity 2200 to 2500 kg, High Density Polyethylene material all complete. 4 Nos. 8,850.00 35,400.00
48 X 40 X 8 (inches)
23 24 SITC of POTATO PILLER Comprising: 20 GA SS body, electrically operated with electric motor of 1 No. 48,616.00 48,616.00
Power : 2 HP, 220V of ISI mark, all complete as per manufacturer specifications.
KITCHEN VENTELATION SYSTEM - -
24 V1 SITC of SS HOOD WITH SS FILTER Comprising: 22 GA. SS Welded Body Construction, with 1 No. 25,960.00 25,960.00
Removable 20 GA. SS "V" section filters set in continuous channel, to be suspended on ceiling with
hanger rods of sufficient capacity all complete. 54 X 30 X 24
25 V2 SITC of SS HOOD WITH SS FILTER Comprising: 22 GA. SS Welded Body Construction, Removable 3 Nos. 16,520.00 49,560.00
20 GA. SS "V" section filters set in continuous channel, To be suspended on ceiling with hanger rods of
sufficient capacity all complete. 36 X 30 X 24
26 V5 SITC of GI DUCTING FOR HOT AIR SUCTION Comprising: 22 GA. GI sheet ducting as per requiremt 50 SQM 1,888.00 94,400.00
as site requirement all complete.
27 V6 SITC of FAN FOR HOT AIR SUCTION Comprising: Electric Motor of Comptron or equivalent make - 3 1 No. 49,796.00 49,796.00
HP Power/ 2.25 KW, 440V ISI mark as per manufacturer specifications complete.
(motor Capacity)
KITCHEN LPG SYSTEM - -
28 L1 SITC of 10 CYLINDER (5 X 2 = 10) LPG GAS MANIFOLD SYSTEM WITH ALL FITTINGS 10 Nos. 3,127.00 31,270.00
COMPLITE SET Comprising:
1" dia pipe M.S. manifold,
10 no Non-Retrun-Valve, 10 cylinder pigtail, 10 no clicon addaptor,
2 no ball valve, 10 CYLINDER
1 no Double-Bottle-Connection (capacity)
1 no perset regulator,
1 no adjustable regulator,
1 no pressure gauge, all complete
Digitally signed by VARUN
Construction of Eklavya Model Residential School (EMRS)” at Darbha, District- Bastar Chhattisgarh
ABSTRACT OF COST (Kitchen Machinery)
S. No. COD Description of works SIZE Quantity Sample Image Rate i/c GST@18% Amount
29 L2 SITC of 1/2" DIA LPG PIPE LINE FROM MANIFOLD TO ALL LPG EQUIPMENTS WITH 61.00 metre 3,186.00 1,94,346.00
CONNECTION COMPLITE SET Comprising:
1/2" dia M.S. pipe line,
1 no pressure gauge with valve & Needle Control Valve, 60 Metre
all connection - 1 no socket, 1no Needle Control Valve, 1no burnner pigtel APPROX
clump, bend, socket, union set, painted with yellow paint etc including neccesary leakage testing all
Digitally signed by VARUN
Construction of Eklavya Model Residential School (EMRS)” at Darbha, District- Bastar Chhattisgarh
ABSTRACT OF COST (FURNITURE)
Item Specification Items Sample Image Quantity Unit Rate i/c GST Amount
1 Supplying and installing at site knock down type class room Dual Desk specially designed for rugged use. The dual desk shall be made of ERW M.S. Duel Desk
tubular section fitted with pre-laminated particle board top, seat & back with 2mm thick machine pressed PVC egde banding glued with industrial
adhesive and diffused with board monolithically alongwith MS hook/hanger for water bottle and bag. All the exposed corners shall be rounded with a
fillet/corner radius upto 50mm. The overall appearance of the finished product shall be strictly as per sample photographs attatched:
DUAL DESK TOP –18 mm Both Side Laminated (BSL) PreLam Partical Board 400 mm wide
BENCH/SEAT TOP – 18 mm BSL PreLam Partical Board 330 mm wide
FRONT SHELF – 18 mm BSL PreLam Partical Board 300 mm (Wide).
BENCH BACK – 18 mm BSL PreLam Partical Board 250 mm (W).
Modesty Panel – 18 mm BSL PreLam Partical Board 300 mm (W).
Supporting Understrucure- Left Hand and Right Hand frame consisting of vertical, horizontal and Cross Member made up of 25 mm outer dia x 1.2
mm (wall thickness) ERW tube confirming to IS Grade 4923:1997 and shall be finised with epoxy polyster powder coated finish with DFT 50-60
Micron confirming IS 13871:1993. The support system of Bench and Shelf shall also made up of made up of 25 mm (outer dia) x 1.2 mm outer dia
ERW tube confirming to IS Grade 4923:2019 and shall be finised with epoxy polyster powder coated DFT 50-60 Micron confirming IS 13871:1993.
Resting support plate made of Table top , provided on the top of vertical members shall be made up of 3mm Thk CRCA Steel sheet Conforming IS:
513:2008. The legs shall be fitted with PVC Leveler. Construction is fully welded with MIG welding and assembled using M6 trilobular screws (As
per DIN 7500) with Zn blue plating. Compact top, seat and back panels are assembled using M6 Countersunk Trilobular screws(as per DIN 7500)
with Zn Black Plating (As per IS 1573:1986). The Dual Desk shall design shall ensure comfortability in entering, seating and standing during use.
1(a) Dual Desk- Overall Size 1050-1100 mm (W) x 930-940mm (D) x 650mm (H) - Desk Depth 390-400mm. Seat Height 375mm (for Classs 6-8) 96.00 Each 6,955.17 6,67,696.32
1(b) Dual Desk- Overall Size 1050-1100 mm (W) x 975-985mm (D) x 750mm (H) - Desk Top 400mm. Seat Height 450mm (for Classs 9-12) 160.00 Each 7,500.00 12,00,000.00
2 Supplying and installing at site knock down type Office Table as per approved design and directrion of Engineer-in-charge. Principal & Vice - -
Work Top - Work top shall be made 25mm thick Pre-laminated MDF board with decorative lamination on one side and balancing lamination on other Principal Table
side confirming to IS 12406:2003 with post forming on front, back and machine pressed PVC egde banding 2mm thick glued with industrial adhesive
and diffused with board monolithically on other two sides. Table top shall have 75mm overhung on front and 25mm overhung on sides.
Understructure- C-type leg shall be made of tubular section of 50mm x 50mm x 1.6mm (wall thickness) thick vertical member and 40mm x40mm
x1.6mm (wall thickness) Horizontal M.S. pipe confirming IS-Grade 4932 shall be finished with epoxy polyster powder coated DFT 50-60 Micron. The
legs shall be fitted to the ground with M8 screw leveler with the height adjustment up to 15mm. The cross members shall be mounted by end brackets
made of 3mm thick CRCA steel sheet confirming IS 513: 2008 and finished with epoxy polyster powder coated DFT 50-60 Micron confirming IS
Wire management - Electrical wires shall be carried from horizintal/ vertical duct made of 0.7mm CRCA steel sheet confirming to IS 513:2008. The
switch plate or grommet depending upon requirement shall also be provided for electrical/LAN connection on table top.
Modesty Panel -Modesty Panel of height 450mm shall be made of 1.5mm thick CRCA sheet sheet confirming to IS 513: 2008 and shall be finised
with epoxy polyster powder coated DFT 50-60micron.
Storage body- Storage top shall also be made of 25mm thick Pre-lam MDF board confirming to IS 12406:2003 with post forming on two sides and
machine pressed PVC egde banding 2 mm thick glued with industrial adhesive and diffused with board monolithically on other two sides. The body of
storage units shall be made of 0.8mm thick CRCA steel Sheet and skirting shall be of 1.2mm thick CRCA steel sheet confirming to IS 513: 2008
finished with epoxy powder coated of DFT 50-60 Micron confirming IS 13871:1993. Internal Shelves shall be also made up of 0.8mm CRCA steel
sheet confirming to IS 513: 2008 and shall be mounted with the Metal shelf support pin made of 2mm thick CRCA Steel sheet with Nickel or Chrome
plating. M10 screw leveler is given with height adjustment up to 12mm to 15mm.
2(a) Table of Size 1800mm (W) x 750mm (D) x 750mm (H) with Side Storage of Size 900mm (W) x 450mm (W) X 750mm (H) and Back Storage Prinicipal Table 1.00 Each 47,746.00 47,746.00
Construction of Eklavya Model Residential School (EMRS)” at Darbha, District- Bastar Chhattisgarh
ABSTRACT OF COST (FURNITURE)
Item Specification Items Sample Image Quantity Unit Rate i/c GST Amount
2(b) Table of Size 1650mm (W) x 750mm (D) x 750mm (H) with Side Storage of Size 900mm (W) x 450mm (W) X 750mm (H) and Back Storage 1650 Vice Prinicipal Table 1.00 Each 42,258.00 42,258.00
2(c) Office table with overall Size of desk 1350mm (L) x 750mm (W) x 750mm (H)& Side Storage Unit of size 900mm (L) x 450mm (W) x 750mm (H) Office Table 6.00 Each 23,598.00 1,41,588.00
3 Supplying and installing at site knock down type Office Table made of Pre-laminated MDF board with decorative lamination on one side and Teacher's table 25.00 Each 6,037.00 1,50,925.00
balancing lamination on other side top of size 1199 X 590 X 735 mm. Worktop shall be rounded in all four corners and should have an overhung of
50mm alongwith one drawer unit made of 0.5mm thick CRCA Steel sheet. The table top shall be supported over legs consists of MS ERW round tube
of 25mm dia x 1.2mm (wall thickness) and Cross Horizontal Members including Leg rest of 25mm dia x 1.2mm (wall thickness) M.S. ERW tube. All
steel components be shall be finised with epoxy polyster powder coated DFT 50-60micron.
4 Supplying and installing at site knock down type 12 Seater Meeting Table of of overall size 3600 x 1350 (maximum) x 750 mm (Knock down type). Meeting Table 2.00 Each 44,453.00 88,906.00
Table Top shall be made of 25mm thick Pre-laminated Partical Board with decorative lamination on one side and balancing lamination on other side
whereas the Gable Ends shall be of 25mm thick Pre-laminated Partical Board with decorative lamination on both side alongwith 2mm thick machine
pressed PVC edge banding glued with industrial adhesive and monolithically diffused.
Supporting Understructure consists of 2 Metal C Legs on either ends of table support frame made of 50mm x 50mm x 1.6 mm (wall thickness) MS
ERW tube and One number Wire Carrier leg at middle of 50mm x 50mm x1.6mm (wall thickness), 4 numbers Horizontal connector of 40mm X
40mm X 1.6mm thick MS Pipe between supporting vertical legs. All The MS Pipes and Sheet shall be finished with epoxy powdercoated of DFT 50-
60micron. The 'C' typed metal legs shall be kept 150mm inside from outer edge of table top. WIRE MANAGEMENT - The Vertical (stake)
& Horizontal (cable tray) wire carriers are placed below worktop, made up of CRCA steel sheet with epoxy powder Coating & Fixed to the
understructure with specially designed brackets, including provision of placing switch plates/grommet in the cable tray .
5 Supply and Istallation of Library Table in sizes of 2400mm (L) x 900mm (W) x 750mm (H) consisting of follwing specification:- LibrararyTable 10.00 Per Unit 13,720.00 1,37,200.00
Work Top - Work top shall be made of 25mm thick Pre-laminated Partical Board with decorative lamination on one side and balancing lamination on
other side confirming to IS 12823: 1990, alongwith 2 mm thick Machine pressed PVC edge banding glued with industrial adhesive and monolithically
diffused with board on exposed edges.
Understructure Supporting frame shall consists of Three Metal C-Legs (two at either ends and one in middle of table) and joined by two numbers
Horizontal connector made of tubular section 40mm x 40mm x 1.6mm (wall thickness) confirming to IS 4923:1997. The table shall have provisions
of foot-rest made up of 25mm x 25mm x 1.2mm ERW M.S. pipe fitted in between two vertical legs and also acts as bracing member.The entire metal
frame shall be finised with epoxy polyster powder coated DFT 50-60 Micron. C-typed metal legs shall be kept 150 mm inside from from end of table.
Legs shall be fitted to the ground with M8 screw leveler with the height adjustment up to 12mm to 15mm.
Construction of Eklavya Model Residential School (EMRS)” at Darbha, District- Bastar Chhattisgarh
ABSTRACT OF COST (FURNITURE)
Item Specification Items Sample Image Quantity Unit Rate i/c GST Amount
6 Supplying and installing at site knock down type Dual Computer Work Station of unit Size 1500mm (L) x 600m (W) x 750mm (H) for two students Computer Work 18.00 Per dual 16,500.00 2,97,000.00
Work Top- Work top shall be made 25mm thick Prelam particle board with decorative lamination on one side and balancing lamination on other side Station Unit
confirming to IS 12823: 1990 with 2mm thick Machine pressed PVC edge banding glued with industrial adhesive and monolithically diffused with
board on all sides.
Understructure supporting frame consist of 2 Metal C Legs on either ends of table support frame made of 50mm x 50mm x 1.6 mm (wall thickness)
MS ERW tube and One number Wire Carrier leg at middle of 50mm x 50mm x1.6mm (wall thickness), 4 numbers Horizontal connector of 40mm X
40mm X 1.6mm thick MS Pipe between supporting vertical legs. The MS Pipes shall be finished with epoxy powdercoated with DFT of 50-60
Micron confirming to IS 13871:1993. The legs shall be fitted to the ground with M8 screw leveler with the height adjustment up to 15mm.
Wire management-The Vertical /Electrical duct & Horizontal Cable tray ( wire carriers) are made of CRCA steel sheet & fixed to the understructure
below worktop with specially designed brackets. Provision for fixing Switch plates are privided in the cable tray for easy access through wire
mangaer or PVC grommet.
Screens / privacy panel: - Screen height will be 300mm above work-top made of prelam particle board/White Board alternatively as approved by
Engineer-in-Charge. In addition privacy panel of 300 mm height, on work top, shall be provided between two workstation.
7 Supply and Istalltion of Library Open book Shelf (Single Side) of Sizes 1800mm (H) x 900mm (W) x 316mm (D) body and shelves shall be made up One Side book Shelf 10.00 Each 14,488.00 1,44,880.00
of 0.8mm thick CRCA steel Sheet and skirting of 1.2mm thick CRCA steel sheet confirming to IS 513: 2008 and fixed with CRCA steel sheet
brackets of approved design finished with epoxy powder coated finish (DFT minimum 50-60 micron). Number of adjustable shelf shall be five with
six loading levels . Load bearing capacity of the shelf shall be 30Kgs UDL. The construction shall be aesthetically appealing completely welded. M10
screw leveler with height adjustment up to 15mm shall be provided at bottom end of legs.
8 Supply & Placing of Glass-door Storage of Size 916 mm (W) x 486mm (D) x 1980mm (H). It should have shelf thickness of 0.7mm, Back thickness Steel Glass Door 6.00 Each 25,989.00 1,55,934.00
of 0.8mm, Door thickness of 0.8mm (high yield strength) with clear glass of 3.0mm thick and all other components shall have a thickness of 0.9mm. Almira
These components shall be made of CRCA steel sheet ‘D’ grade high yield strength as per IS 513:2008 The glass door storwel shall have a SS handle
and a Two-way locking mechanism with shooting bolt. It should have a height-wise adjustable shelf mounting which shall have a Uniformly
Distributed Load Capacity of max 40 Kg. It should also have a M10 Screw type Leveller with Hex plastic base.All metal components would be epoxy
polyster powder coated DFT 50-60 Micron confirimg to IS 13871:1993
9 Supply & Placing of Metal Almirah of Size 916mm (W) x 486mm (D) x 1980mm (H). It should have the shelf thickness of 0.7 mm, Back thickness of Steel Almira 10.00 Each 22,422.00 2,24,220.00
0.8mm, Door thickness of 0.8mm (high yield strength) and all other components shall have a thickness of 0.9mm. These components shall be made of
CRCA steel sheet ‘D’ grade high yield strength as per IS:513. The Storwel Plain should have a suitable handle and Three-way locking mechanism
with Shooting Bolts. It should have a height wise adjustable shelf mounting which shall have a Uniformly Distributed Load Capacity of max 40 Kg. It
shall have 4 no.s full shelves. A4 size box file(85 W x 285 D x 345 H mm) can be stored vertically on three shelves and the clear space above fourth
shelf is 240mm. It should also have a M10 Screw type Leveller with Hex plastic base. All metal components would be powder coated with epoxy
powder coating of 50-60 micron DFT Confirming IS 13871:1993
Construction of Eklavya Model Residential School (EMRS)” at Darbha, District- Bastar Chhattisgarh
ABSTRACT OF COST (FURNITURE)
Item Specification Items Sample Image Quantity Unit Rate i/c GST Amount
10 Supply and Istallation of 5- Seater sofa consisting of one number 3-Seater Sofa of overall size (1950mm x 785mm x 750mm ) and one number 2- One Set of 5 Seater 1.00 Per Set 66,405.00 66,405.00
Seater Sofa (1550mm (W) x 785mm (D) X 750mm (H), under-structure is made up of Natural Hard wood battens and 12mm THK COMMERCIAL Sofa (1-3 seater &1-
PLYWOOD. High density foam shall be used for seat and back. The seat is made up of PU foam with density 32±2 Kg/m3 having an additional top 2 seater)
layer of PU foam with density 28±2 Kg/m3, upholstered with leatherette. The back is made up of PU foam with density 28+/-2 Kg/m3 with additional
top layer of PU foam with density 23+/-2 Kg/m3, upholstered with leatherete. LEATHERITE -ABRASION RESISTANCE in excess of 80,000
cycles, 600 to 650 GSM. Legs shall be made Mild Steel (MS) powder coated with minimum 50-60 micron DFT confriming IS 13871:1993
11 Supply and Installation of 4-seater sofa consisting of two number 2-Seater Sofa (1550mm (W) x 785mm (D) X 750mm (H), understructure is made up One Set of 4 Seater 2.00 Per Set 61,466.00 1,22,932.00
of Natural Hard wood battens and 12mm THK COMMERCIAL PLYWOOD. High density foam is used for seat and back , The seat is made up of Sofa (2-2 seater)
PU foam with density 32±2 Kg/m3 having an additional top layer of PU foam with density 28+/-2 Kg/m3, upholstered with leatherette. The back is
made up of PU foam with density 28±2 Kg/m3 with additional top layer of PU foam with density 23+/-2 Kg/m3, upholstered with leatherette.
LEATHERITE -ABRASION RESISTANCE in excess of 80,000 cycles, 600 to 650 GSM. Legs shall be made Mild Steel (MS) powder coated
with minimum 50-60 micron DFT confriming IS 13871:1993
Construction of Eklavya Model Residential School (EMRS)” at Darbha, District- Bastar Chhattisgarh
ABSTRACT OF COST (FURNITURE)
Item Specification Items Sample Image Quantity Unit Rate i/c GST Amount
12 Supply and installation of Steel bed of overall size 1850mm (L) x 875mm (W) x 650/450mm (H) consisting of following specification:- Metal Bed 486.00 Each 10,438.01 50,72,871.40
HEADBOARD: Head Board consists of MS tube of 25 x 50 x 1.6 mm thick vertical legs connected with 2 number horizontal members of MS ERW
tube 25mm x 50m x 1.6mm (wall thickness) and one number MS ERW tube of 25mm x 25mm x 1.6mm (wall thickness) at middle confirming to IS
4923:1997. The construction is partially welded with MIG welding confirming to IS standard IS 816:1969 and is also tested as per the IS grade IS
822:1970. Legs shall be fitted to the ground with M8 screw leveler with the height adjustment up to 12mm to 15mm, if required. Head Board and Tail
board are connected to middle frame with 2 mm thick CRCA bracket confirming to IS 513: 2008.Connecting bracket is welded on vertical pipe. End
to end dimensions for the Headboard is 875mm (W) x 650mm (H). Whole Assembly is finished with epoxy powder coated of a minium thickness of
DFT 50-60 Micron confirming to IS 13871:1993.
TAILBOARD-Tail Board consists of vertical legs of MS ERW tube of 25x50x1.6mm thick connected with one number horizonal MS pipe
50x25x1.6mm thick Conforming IS 4923:1997. Construction is partially welded with MIG welding confirming to IS standard IS 816:1969 and
welding is also tested as per the IS grade IS 822:1970. Legs shall be fitted to the ground with M8 screw leveler with the height adjustment up to
12mm to 15mm if required .To connect Tailboard with middle frame 2mm thick CRCA sheet bracket is used conforming IS 513: 2008 . Connecting
bracket is welded on vertical pipe. End to end dimensions for the Tailboard is 875mm (W) x 450mm (H). The whole assembly shall be finished with
epoxy powder coated of a minium thickness of DFT 50-60micron confirming to IS 13871:1993.
Bed Stagging– Head board and Tail boad are joined togather by bed stage made up of 12 mm Merine grade ply supported over steel framework
consisting of two outer MS ERW Pipe 25x50x1.2mm thick and 03 numbers cross braccing of MS ERW pipe of 25x25x1.6mm thick in middle
conforming IS 4923:1997 and welded to each other by MIG welding. End to end dimensions for the middle frame is 1725-1775(L)x825mm(W) for
mattress size of 1725-1775 x 800 mm.
FINAL ASSEMBLY: Headboard, Tailboard, and middle frame shall be assembled and connected by 4 Nos of connecting Brackets & M8x16 Allen
Bolt. The bed stage shall be 10-12 mm below side frame to provide proper fixity to mattress. End to end dimensions for the bed is 1850
Finish- All metal components are given anti-rust surface treatment and are finised with epoxy polyster powder coated DFT 50-60 Micron confirming
(Note- The overall sizes of bed shall be kept 1850mm x 875mm (to fit a mattress of size 1775mm x 800mm. The mattress shall be procured
13 Supplying and installing at site knock down type Metal Table with Integrated Storage 1750mm (L) x 600mm (W) x 750mm (H) for two students Metal Table with 240.00 Each 3,500.00 8,40,000.00
Work Top Shall be made up of 25mm thick Prelam (OSL) particle board confirming to IS 12823: 1990 with 2mm thick Machine pressed PVC edge Integrated Storage
banding glued with industrial adhesive and monolithically diffused with board on all sides. 1750(L) x 600(W) x
Supporting Strucure of table top consits of 4 vertical Legs of ERW M.S. tube 40 x 40 x 1.6 mm and one storage unit at middle. The vertical legs are 750(H).
connected with 2 cross horizontal members of size ERW M.S.Tube of 40 x40 x 1.6 mm provided at top. The table shall have provisions of foot-rest
made up of 25mm x 25mm x 1.2mm ERW M.S. pipe fitted in between two vertical legs and also support the storage unit & acts as bracing member.
All ERW pipes shall confirm to IS 4923: 1997 and shall be finised with epoxy polyster powder coated DFT 50-60 Micron Confirming IS 13871:1993.
Drawer Unit: SPECIFICATIONS :-
Table shall have 2 numbers of Metal Storage consiting of Shutter of size consiting of 350 (W ) x 550 (D) x 280 (H) mm with provision for Pad Lock.
All metal component including shutter and Shelf shall be made of 0.8 mm thick CRCA steel sheet confirm to IS 4923 : 1997 and shall be powder
coated with epoxy powder coating of DFT 50-60 Micron Confirming IS 13871:1993.
Construction of Eklavya Model Residential School (EMRS)” at Darbha, District- Bastar Chhattisgarh
ABSTRACT OF COST (FURNITURE)
Item Specification Items Sample Image Quantity Unit Rate i/c GST Amount
14 Supplying and installing at site knock down type SS Dinning Table consists of Dinning Top made up of 1mm thickness Stainless steel sheet of SS 304 8 Seater SS Top 4.00 Each 46,648.00 1,86,592.00
Grade with overall dimension of 2400mm (L) X 760mm (D) X 750mm (H). The table top shall be reinforced with a 18mm thick HDHMR Board. Fixed Canteen Table
Dinning top sheet shall be extended to the sides for a depth upto 24 mm under the table top in all directions including , edge rounding, grinding and 2400 x 750
finishing ,etc all complete . The Table top shall finish in such a manner to avoid any sharp edges.
Supporting understrucure of table consists of 4 numbers C- Leg frame made up of MS ERW tube 40mm x 40 mm x 1.6 mm and are connected to 6
numbers horizontal members of MS ERW tube 25 x 25 x 1.6 mm.
Stool Seats shall be made of 300mm dia SS 202 Grade formed Plates of 1mm thick resting over 12mm HDHMR which in turn supported over 3mm
thick MS Plate welded to vertical supporting leg.
The supporting vertical member of each stool seat consists of MS ERW tube 40mm x 40 mm x 1.6 mm and is connected to C-legged frame of table
top. All Metal components of entire assembly confirm to IS 4923: 1997. Both the horizontal and vertical pipes are welded together by MIG welding
confirming to IS standard IS 816:1969 and is tested for welding confirming to IS 822:1970. All CRCA Steel componets shall be finised with epoxy
polyster powder coated DFT 50-60 Micron confirming IS 13871:1993.
The understructure height shall be 725mm from the ground and stool shall height of 500mm from the ground & foot rest structure of MS ERW tube
of 40 x40 x 1.6 mm , shall be 125mm from ground.
15 Supplying and installing at site knock down type SS Dinning Table consists of Dinning Top made up of and 1mm thickness stainless steel sheet of SS 6 Seater SS Top 30.00 Each 38,000.00 11,40,000.00
304 Grade with overall dimension of 1800mm (L) x 760mm (D) x 750mm (H). The table top is rainforced with a 20mm HDHMR Board. Dinning top Fixed Canteen Table
sheet shall be extended to the sides for a depth of 24 mm in all directions including , edge rounding, grinding and finishing ,etc all complete . The 1800 x 750
Table top shall finish in such a manner to avoid any sharp edges.
Supporting understrucure of table consists of 3 numbers Leg frame made up of 40mm x 40mm x 1.6mm M.S. ERW tube and are connected to 4
numbers horizontal members of MS ERW tube 25mm x 25mm x 1.6 mm.
Stool Seats are made of 300 mm dia SS 202 Grade formed Plates of 1 mm thickness resting over welded 12 mm HDHMR which in turn supoorted
over 3 mm thick MS Plate weled to vertical supporting leg.
The supporting vertical member of each stool seat consists of MS ERW tube 40mm x 40 mm x 1.6 mm and is connected to C-legged frame of table
top. All Metal components of entire assebmly confirm to IS 4923: 1997. Both the horizontal and vertical pipes are welded together by MIG welding
confirming to IS standard IS 816:1969 and is tested for welding confirming to IS 822:1970. All CRCA Steel components shall be finishded with
epoxy polyster powder coated DFT 50-60 Micron confirming IS 13871:1993.
Understructure height will be 725mm from the ground, the stool height will be 500mm from the ground foot rest structure of MS ERW tube 40mm x
40 mm x 1.6 mm, shall be 125 mm from goound.
16 Supply and installation of Lab Stool Seat made up of 300 mm dia SS 202 Grade formed Plates of 1 mm thickness welded over 3 mm thick MS Plate Lab Stool 93.00 Each 2,689.00 2,50,077.00
and 12 mm HDHMR Board . The Stool seat is supported by four legs 25mm dia x 1.6 mm M.S. round Pipe. Height of stool shall be 540mm from the
floor. The legs shall be provided with PU/PVC leveller at the bottom and finished with epoxy powder coated finish (DFT 50-60 Micron) Confirming
Construction of Eklavya Model Residential School (EMRS)” at Darbha, District- Bastar Chhattisgarh
ABSTRACT OF COST (FURNITURE)
Item Specification Items Sample Image Quantity Unit Rate i/c GST Amount
17 Supplying & placing in position High back Executive Chair as per indicative photograph and specification: High Back Chair 1.00 Each 11,950.00 11,950.00
i) SEAT/BACK ASSEMBLY: The seat and back should be made up of 12 ±1mm. thick hot-pressed plywood and upholstered with fabric upholstery
covers and moulded Polyurethane foam. The back foam should be designed with contoured lumbar support for extra comfort. The seat has extra thick
foam on front edge to give comfort to popliteal area.
BACK SIZE 47.5 cm. (W) x 69.5 cm (H)
SEAT SIZE 47.0 cm. (W) x 48.0 cm. (D)
ii) HIGH RESILIENCE (HR) POLYURETHANE FOAM: The HR polyurethane foam should be moulded with density = 45±2 kg/m3 and hardness
load 16 ± 2 kgf for 25% compression.
iii) ARMRESTS :The one-piece armrests should be injection moulded from black Co-polymer Polypropylene.
iv) CENTER TILT SYNCHRO mechanism: The mechanism should be designed with the
following features:
• 360° revolving type. • Upright-position locking • Tilt tension adjustment • Seat/back tilting ratio of 1:3.
v) PNEUMATIC HEIGHT ADJUSTMENT: The pneumatic height adjustment has an adjustment stroke of 12.0 ±0.3cm.
vi)TELESCOPIC BELLOW ASSEMBLY The bellow should be 3 piece telescopic type and injection moulded in black Polypropylene.
vii) PEDESTAL ASSEMBLY:The pedestal should be injection moulded in black 33% glass-filled Nylon-66 and fitted with 5 nos. twin wheel castors.
The pedestal should be 66.3 ±0.5cm. pitch-center dia. (76.3 ±1.0cm with castors).
viii)TWIN WHEEL CASTORS: The twin wheel castors should be injection moulded in Black Nylon.
18 Supplying & placing in position medium back Executive Chair as per indicative photograph and specification: Medium Back Chair 1.00 Each 10,684.00 10,684.00
i) SEAT/BACK ASSEMBLY: The seat and back should be made up of 1.2 ±0.1cm. thick hot-pressed plywood and upholstered with .fabric
upholstery covers and moulded Polyurethane foam. The back foam should be designed with contoured lumbar support for extra comfort. The seat has
extra thick foam on front edge to give comfort to popliteal area
BACK SIZE 47.5 cm. (W) x58.0 cm (H)
SEAT SIZE 47.0 cm. (W) x 48.0 cm. (D)
ii) HIGH RESILIENCE (HR) POLYURETHANE FOAM: The HR polyurethane foam should be moulded with density = 45±2 kg/m3 and hardness
load 16 ± 2 kgf for 25% compression.
iii) ARMRESTS :The one-piece armrests should be injection moulded from black Co-polymer Polypropylene.
iv) CENTER TILT SYNCHRO mechanism: The mechanism should be designed with the
following features:
• 360° revolving type. • Upright-position locking • Tilt tension adjustment • Seat/back tilting ratio of 1:3.
v) PNEUMATIC HEIGHT ADJUSTMENT: The pneumatic height adjustment has an adjustment stroke of 12.0 ±0.3cm.
vi) TELESCOPIC BELLOW ASSEMBLY : The bellow should be 3 piece telescopic type and injection moulded in black Polypropylene.
vii) PEDESTAL ASSEMBLY:The pedestal should be injection moulded in black 33% glass-filled Nylon-66 and fitted with 5 nos. twin wheel castors.
The pedestal should be 66.3 ±0.5cm. pitch-center dia. (76.3 ±1.0cm with castors).
viii)TWIN WHEEL CASTORS:The twin wheel castors should be injection moulded in Black Nylon.
Construction of Eklavya Model Residential School (EMRS)” at Darbha, District- Bastar Chhattisgarh
ABSTRACT OF COST (FURNITURE)
Item Specification Items Sample Image Quantity Unit Rate i/c GST Amount
19 Supplying & placing in position visitor Chair as per indicative photograph and specification: Visitor Chair 53.00 Each 8,091.00 4,28,823.00
i) SEAT/BACK ASSEMBLY: The seat and back should be made up of 12 ±1mm. thick hot-pressed plywood and upholstered with fabric upholstery
covers and moulded Polyurethane foam. The back foam should be designed with contoured lumbar support for extra comfort. The seat has extra thick
foam on front edge to give comfort to popliteal area.BACK SIZE 47.5 cm. (W) x58.0 cm (H)
SEAT SIZE 47.0 cm. (W) x 48.0 cm. (D)
ii) HIGH RESILIENCE (HR) POLYURETHANE FOAM: The HR polyurethane foam should be moulded with density 45±2 kg/m3 and hardness
load 16±2 kgf for 25% compression.
iii) ARMRESTS :The one-piece armrests should be injection moulded from black Co-polymer Polypropylene.
iv) TUBULAR FRAME: The powder coated (DFT 50-60 Micron ) pressed tubular frame should be
cantilever type & made of 25±2 mm. x 2mm (thick) M.S. ERW Tube.
20 Supplying & placing in position chair with MOULDED PLY SHELL: The seat & back is made up of moulded ply in Veneer or Laminate finish in Chair without arm 480.00 Each 2,662.00 12,77,760.00
single piece of
Shell size - 420 mm (W) X 410 mm (D) X 440 (H) X Thickness 12 mm.
UNDER STRUCTURE:
The Understructure is made up of dia. 25.4 ±0.3mm. x 1.6mm thick M.S. E.R.W. tube supporting frame in C-shape and welded to 250mm x 250mm
x 2mm thick MS plate welded at seat level to support seat with necesary fixing arrangement . The framework shall be epoxy coated having DFT 50-60
The leg at bottiom shall be fitted to rubber bush.
21 Supplying & placing in position in position Wooden chair of Dimension - 480W x 420D x 820H Chair without arm 80.00 Each 3,732.00 2,98,560.00
UNDERSTRUCTURE:The Understructure is made from Hot pressed rubber wood.
BACKREST: The backrest is made up of plywood and foam upholstered with polyester fabric.
SEAT:The seat is made up of 12mm thick (7 layers) hot pressed plywood and moulded seat foam upholstered with fabric.
SEAT FOAM: Foam made out of moulded Polyurethane foam with the following properties:
• Density (IS-7888-1976) : 50-55 Kg/m3.• Hardness: 28+/-3 Kgf.• Compression set (IS-7888-1976): 10% Max.• Tensile strength (IS-7888-1976): 0.9-
1.2 Kg/cm2• Tear strength(Min) (IS-8067) : 0.6 Kg/cm(min)• Resilience (IS-7888-1976): 40% - 60% • Elongation (IS-7888-1976): 110 %
GLIDE:The glide is made from Nylon.
SEAT AND BACK FABRIC PROPERTIES: Content: 100% Polyester
170 GSM Abrasion Resistance:Over 30000 cycle.Bursting Strength: 19.1 kg/cm²Tear Strength (NF).
20 Supplying & placing in position in position Steel chair as per specifcation detailed below:- Chair without arm 61.00 Each 3,677.00 2,24,297.00
1)SEAT/BACK ASSEMBLY: The seat and back should be made from 10±0.01mm. thk. hot pressed ply and should be true resistant tant
commercial plywood and upholstered with P.U. foam and fabric.
BACK SIZE: 420 mm. (W) X 265mm (H) SEAT SIZE: 420mm. (W) X 420mm.
2)HIGH RESILIENCE (HR) POLYURETHANE FOAM: The HR Polyurethane foam should be moulded with density =45+1-2 kg/m3 and Hardness
load 16 ± 2 kgf for 25% compression.
3)UNDERSTRUCTURE ASSEMBLY : The assembly should be a mainframe made of 25.4 ±0.3mm. x 1.6mm thick M.S. E.R.W. tube and a
welded leg tube made of dia. 25.4 ±0.3mm. x 1.6mm thick M.S. E.R.W. tube .to the form the complete assembly which should be black powder
coated ( DFT 50-60 Micron ). Note-Colour of fabricc may be decised by engineer-incharge considering overall colour scheme.
Construction of Eklavya Model Residential School (EMRS)” at Darbha, District- Bastar Chhattisgarh
ABSTRACT OF COST (FURNITURE)
Item Specification Items Sample Image Quantity Unit Rate i/c GST Amount
21 Supplying and installing in position Metal Lockers with Cam Lock one unit consiting of 381mm (W) x 381mm (D) x 1831mm (H) with 4 Lockers. Personal Locker Unit 8.00 Each 12,622.00 1,00,976.00
Body-LH and RH Side and back panel is made up of 0.8mm thick CRCA steel sheet confirming to IS 513:2008 which is having standard dimension
1831 x380mm. Shelf hanging bracket is welded on both the side panel by spot welding. Shelf hanging bracket is made up of 0.8mm thick CRCA steel
sheet confirming to IS 513:2008. front frame, top and bottom part made up 0.8mm thick CRCA steel sheet confirming to IS 513:2008 and horizontal
part is made up 1mm thick CRCA Steel sheet confirming to IS 513:2008. On a front frame horizontally provision is given at a common distance to
hold shutter bracket. Locker’s top is made up of 0.8mm thick CRCA Steel sheet confirming IS 513:2008 which is having standard dimension 375
x378mm. Shelf is also made up of 0.8 mm CRCA Steel sheet confirming to IS 513:2008.
Shutter- Is made up on 0.7mm thick CRCA Steel sheet confirming to IS 513:2008. All the shutter are hung on shutter pin and shutter bracket, louvers
are given in shutter for air flow. PVC flush handle and name plate is used for handling and for name plate tagging. Standard locking arrangment is
used for locking each shutter.
The bodies including shelves are given anti-rust surface treatment & are powder coated with epoxy polyester powder coating of DFT 50-60 Micron
confirimg to IS 13871:1993.
22(a) Supplying and installing in position Super White' writing grade resin coated steel writing surface conforming to International Standards, 100% smooth Magnetic White 4.00 Each 11,525.00 46,100.00
and 100% scratch-free surface and shall have magnetic property for sticking magnets or magnet impregnated objects. Board
Frame- Satin-finish alloy aluminum (6063-T6) frame and precision engineered paper honeycomb core to make the board 100% warp-free and 100%
flat. Can be mounted in landscape as well as portrait orientation on a wall with the help of built-in wall hanging clips
Excellent erasibility with no ghost-marks, high scratch-resistance with easy-wipe properties and maximum readability with minimum glare makes
Material: Resin Coated Steel Writing Surface, Alloy Aluminum Frame, Paper Honeycomb Core & Virgin ABS Corners.
Size of the board: 1750 mm x 1150 mm
22(b) Supplying and installing in position ‘Green' writing grade melamine writing surface (chalk sheet) conforming to IS:2046/1997, with 100% clean and Melamine Surface 18.00 Each 9,604.00 1,72,872.00
100% scratch-free surface. Non-Magnetic
Frame- Satin-finish alloy aluminium (6063-T6) frame and precision engineered paper honeycomb core to make the board 100% warp-free and 100% Chalk Board-2350
flat. Can be mounted in landscape as well as portrait orientation on a wall with the help of built-in wall hanging clips X 1150 mm’
Excellent erasibility with no ghost-marks, high scratch-resistance with easy- wipe properties, maximum readability with minimum glare and minimum
chalk dust formation with clean & continuous lines of chalk. Works well with all standard chalk sticks
Board Size: 2350 mm x1150mm ).
23 knocked down glass top rectangular centre table with a single storage shelf of 8 mm tempered glass located in the bottom portion shape supported by Tea Table of Size 3.00 Each 10,756.00 32,268.00
a set of four legs. The table's top is made of 10 mm tempered glass, while the frame and legs are constructed from other wood materials. The 1000 x 650 x 450
understructure supporting the top, as well as the storage compartment, are also made of wood, and the shoes/buffers are made of nylon. The mm
dimensions of the table are approximately 1000mmX650mmX430 mm. The legs measure 35mm x 35mm and the understructure support material has
a thickness of 8 millimeters. The legs are connected at the adjacent sides with four buffers/shoes at the bottom of the legs. The table top has a walnut
Construction of Eklavya Model Residential School (EMRS)” at Darbha, District- Bastar Chhattisgarh
ABSTRACT OF COST (FURNITURE)
Item Specification Items Sample Image Quantity Unit Rate i/c GST Amount
24 Supply & installtion of Physics Lab Table of size 1800(L) x 1000(W) x 860(H) with specification as under: Physic Table Size of 6.00 Each 23,500.00 1,41,000.00
Work Top Shall be made up of 25mm thick Prelam (OSL) HDHMR Board confirming to IS 12823: 1990 with post formed edge moulding on Two 1800(L) x 1000 ( W)
side and 2 mm thick Machine pressed PVC edge banding glued with industrial adhesive and monolithically diffused with board on other two sides. x 860( H)
Supporting Strucure of table top consits of 4 vertical Legs of ERW tube 50 x50 x 1.6 mm and one storage unit at middle. The vertical legs are
connected with 2 lateral and 2 longitudinal cross members of size ERW Tube of 40 x 40 x 1.6 mm provided at top and 2 lateral cross members of size
40x40x1.6 mm. The table shall have provisions of foot rest made up of 25 x25 x1.2 mm ERW pipe fitted in between two vertical legs and also support
the storgae unit & acts as bracing member.
All ERW pipes shall confirm to IS grade IS 4923 and shall be finised with epoxy polyster powder coated DFT 50-60 Micron Confirming IS
Drawer Unit: - Table shall have 4 numbers of Metal Storage consiting of Shutter of size consiting of 350 (W ) x 450 (D) x 350 (H) mm with Pad
Lock provision . All metal component including shutter and Shelf shall be made of 0.8mm thick CRCA sheet sheet confirming to IS 513: 2008 and
shall be powder coated with epoxy powder coating of 50 micron DFT Confirming IS 13871:1993.
Analysis of Rate for Civil Items Derived from DSR 2021
Derived from Providing and laying broken autoclaved aerated cement (AAC)
basic rates of blocks and/or bats (light weight, having density 550-650 kg/m3)
DSR 2021 of nominal size 25mm to 65mm in the sunken portion of toilets
upto floor five level all complete as per the direction of Engineer-
Derived from basic rates taken from DSR 2019
Details of cost for 10 sqm x 0.45 m =4.50 cum.
Code Description Unit Quantity Rate Amount
8655 AAC broken block/bats of nomian size 25mm to 65mm Cum 4.50 2650.00 11925.00
Less for using broken AAC block Cum 11925.00 -30% -3577.50
Less for voids Cum 11925.00 -15% -1788.75
2260 Carrige of material Cum 4.50 178.19 801.86
114 Beldar (for making brick bat from broken AAC block) Day 1.50 645.00 967.50
114 Beldar (for laying) Day 1.00 645.00 645.00
124 Mason (brick layer) 2nd class (for laying) Day 0.50 714.00 357.00
Total 9542.11 "W"
Add for water charges @ 1% on A % 645.000 0.01 6.45
Total 9548.56 "X"
Add GST (@12%) on "X" (multiplying factor 0.1405) on % 651.45 0.1405 91.53
Total 9640.09 "Y"
Total 11086.10 "Z"
Cost for 4.50 Cum 11196.96
Cost for 1 Cum 2488.21
6.1.2 Brick work with non modular fly ash bricks conforming to
(Modified) IS:12894, class designation 10 average compressive strength in
foundation and plinth in:
a) Cement mortar 1:6 (1 cement : 6 coarse sand)
Details of cost for one Cubic Metre
(Derived vide DAR-I 2019 item No. 6.1.2 & 6.34.2)
Code Description Unit Quantity Rate Amount
Materials: (as per 6.34.2)
7737 Non modular fly ash bricks conforming to IS:12894 1000 Nos. 0.494 5100.00 2519.40
2201 Carriage of Bricks 1000 Nos. 0.494 437.15 215.95
3.11 Cement mortar 1 : 6 (1 cement : 6 coarse sand) Rate as per Cum 0.25 3686.30 921.58
Item No.3.11 of SH: Mortar
Labour (coeff as per 6.1.2)
123 Mason (brick layer) 1st class Day 0.36 784.00 282.24
124 Mason (brick layer) 2nd class Day 0.36 714.00 257.04
Total 5228.45 "W"
Add for water charges @ 1% % 5228.450 0.01 52.28
Total 5280.73 "X"
Add GST (@12%) on "X" (multiplying factor 0.1405) % 5280.73 0.1405 741.94
Total 6022.67 "Y"
Total 6926.07 "Z"
Cost for 1 Cum 6995.33
10.11.2 Providing and fixing factory made M.S. Tubular shutter for
(Modified) doors, windows and ventilators side /top /centre hung, with Z / T
and like tubular profile of required size, made of 1.60mm thick
M.S. sheet, joints mitred and flash butt welded, including
providing and fixing 95mm long ball type hinges of diameter
16mm, including priming coat of approved steel primer, but
excluding the cost of other fittings, all complete as per approved
design (sectional weight of only M.S. tubular profile shall be
measured for payment).
Code Description Unit Quantity Rate Amount
Analysis of Rate for Civil Items Derived from DSR 2021
Details of cost for a window of area 2.44 sqm (weight 30 kg).
4011 Z/T tubular profile of size 50mm x 23mm with wall thickness Kg 30.000 50.00 1500.00
9977 Carriage of Steel Door/Window LS 40.370 2.12 85.58
9999 Sundries (95mm long ball type hinges of dia 16mm) LS 55.00 2.12 116.60
Labour for fabrication
103 Blacksmith 2nd class Day 0.17 714.00 121.38
Labour for fixing
Apply steel primer (2.44x1.00 for both sides)=2.44 sqm
13.50.3 Rate as per item no 13.50.3 of SH : Finishing Day 2.44 55.50 135.42 "A"
Total 2478.06 "W"
Add 1 % Water charges on "W-A" % 2342.640 0.01 23.43
Total 2501.49 "X"
Add GST on "X-A" (multiplying factor 0.1405) % 2366.07 0.1405 332.43
Total 2833.92 "Y"
Total 3238.70 "Z"
Cost for 30 Kg. 3269.73
Cost for 1 Kg. 108.99
Constructing brick masonry open surface drain consisting of half
brick masonry with common burnt clay F.P.S. (non modular)
bricks of class designation 75 in cement mortar 1:4 (1 cement : 4
fine sand) including 10 cm thick bed concrete 1:5:10 (1 cement: 5
fine sand : 10 graded stone aggregate 40 mm nominal size) and 25
thick cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded
stone aggregate 12.5 mm nominal size) for filling haunches
including 12 mm cement plaster 1:3 (1 cement : 3 coarse sand)
with a floating coat of neat cement inside the drain, its top and
exposed side including disposal of surplus earth complete as per
standard design:
a) 25 cm drain 30 cm average depth, With F.P.S. bricks
Details of cost for 100 Metre long
Code Description Unit Quantity Rate Amount
Cement concrete 1:5:10 (1 cement : ` 5 fine sand : 10 graded Cum 0.63 5660.45 3566.08
stone aggregate 40 mm nominal size)
Rate as per item no 4.1.11 of SH : Concrete Work
Half brick work in bricks of class designation 7.5 in cement Cum 6.00 837.85 5027.10
mortar 1:4 ( 1 cement : 4 coarse sand)
Rate as per item no 6.12.2 of SH : Brick Work
Cement concrete 1:2:4 ( 1 cement : 2 coarse sand : 4 graded stone Cum 0.063 9375.20 590.64
aggregate 20 mm nominal size)
Rate as per item no 4.2.3 of SH : Concrete
12 mm cement plaster 1:3 ( 1 cement : 3 coarse sand) finished Sqm 10.20 386.55 3942.81
with floating coat of neat cement
Top: 2x 10.0m x 0.12m = 2.40 sqm
Total= 10.20 sqm
Rate as per item no 13.9.1 of SH : Finishing
Analysis of Rate for Civil Items Derived from DSR 2021
Rate as per item no 5.9.2 of SH : RCC
Sundries LS 20.00 2.12 42.40 A
Total 14508.13 "W"
Add for water charges @ 1% on A % 42.400 0.01 0.42
Total 14508.55 "X"
Add GST (@12%) on "X" (multiplying factor 0.1405) on % 42.82 0.1405 6.02
Total 14514.57 "Y"
Total 16691.76 "Z"
Cost for 10 Metre 16858.68
Cost for 1 Metre 1685.85
Extra for additional depth for brick masonry open surface drain :
a) 25 cm drain 30 cm depth, with common burnt clay F.P.S. (non
modular) bricks of class designation 7.5
Details of cost for 0.15 Metre extra depth
Description Unit Quantity Rate Amount
Half brick work in bricks of class designation 7.5 in cement Cum 3.00 837.85 2513.55
mortar 1:4 ( 1 cement : 4 coarse sand)
Rate as per item no 6.12.2 of SH : Brick Work
12 mm cement plaster 1:3 ( 1 cement : 3 coarse sand) finished Sqm 3.00 386.55 1159.65
with floating coat of neat cement
Rate as per item no 13.9.1 of SH : Finishing
Sundries LS 5.00 2.12 10.60 A
Total 3683.80 "W"
Add for water charges @ 1% on A % 10.600 0.01 0.11
Total 3683.91 "X"
Add GST (@12%) on "X" (multiplying factor 0.1405) on % 10.71 0.1405 1.50
Total 3685.41 "Y"
Total 4238.22 "Z"
Cost for 10 Metre 4280.60
Cost for 1 Metre 428.05
Derived Deduct for providing M-20 grade concrete instead of M-25 grade
from DSR machine batched and machine mixed design mix for reinforced
2021 basic cement concrete work (Note:- Cement content considered in M-25
rates and M-20 is @ 330 kg/cum and 300 kg/cum respectively) (this
item is applicable for RCC in grade slab only)
Detail of cost for 1 Cum (Ref.: DAR-I/ item No. 5.34.1/DSR
Description Unit Quantity Rate Amount
Cement for M-25 mix = 0.330 tonne
Cement for M-20 mix = 0.300 tonne
Difference = 0.030 tonne
367 Portland Cement tonne 0.03 5000.00 150.00
2209 Carriage of Cement tonne 0.03 145.72 4.37
Plasticizer @ 0.50% of the cement
for M-25 mix = 1.65 Kg
for M-20 mix = 1.50 Kg
Difference = 0.15 Kg
7318 Plasticizer / super plasticizer Day 0.60 29.00 17.40
Total 171.77 "W"
Add for water charges @ 1% on "W" % 171.77 0.01 1.72
Total 173.49 "X"
Add GST on "X" (multiplying factor 0.1405) 173.49 0.1405 24.38
Total 197.87 "Y"
Total 227.55 "Z"
Analysis of Rate for Civil Items Derived from DSR 2021
Cost for 1.00 Cum 229.83
say Rs. -229.85 "P"
16.43.2 (M) Making provision for contraction/ expansion, construction &
longitudinal joints of sixe 10 mm wide x 50 mm deep by groove
cutting machine. As per direction of Engineer-in-charge.
Details of cost for one Cubic Metre
(Derived vide DAR-II 2021 item No. 16.43.2)
Code Description Unit Quantity Rate Amount
Materials: (as per 6.34.2)
9999 Cutting and making joints LS 50.00 2.12 106.00
Total 106.00 "W"
Add for water charges @ 1% % 106.000 0.01 1.06
Total 107.06 "X"
Add GST (@12%) on "X" (multiplying factor 0.1405) % 107.06 0.1405 15.04
Total 122.10 "Y"
Total 140.42 "Z"
Cost for 1 Cum 141.82
Analysis of Rate for Civil Items Derived on the basis of Local Available Market Rates
MR 1 Providing signage viz display/name plate and like of required size
made out of 20 gauge thick stainless steel (304 garde) including
engraved subject matter, message (Hindi/English and / or bi-
lingual), symbols, borders and logo etc. The engraved letter,
borders etc. to be finished with paint etc. of required colour
scheme and the plate to be fixed to wooden/wall surface with
25mm long stainless steel spacer/stud all complete as per direction
of Engineer-in-charge.
Details of cost for 1 no. plate of size 24" x 4" = 96 square inch
(Ref: as per LMR)
signage viz display/name plate of required size made out of 20 One square 96.00 11.00 1056.00
25mm thick stainless steel
long stainless steel spacer/stud
(304 garde) including engraved subject Inch
Carriage of material & fixing charges LS 5.00 25.00 125.00
sundries (finishing engraved letter wirh paint etc.) LS 5.00 25.00 125.00
Labour for fixing LS 10.00 25.00 250.00
Add for water charges @ 1% on "W" % 1616.00 0.01 16.16 "A"
Add 12% GST applicable on work contract, by reversible method 1632.16 0.1405 229.32 "B"
(multiplying factor 0.1405) 1861.48 "X"= (WC+B)
Add for contractor's profit & over-heads @ 15% on "X % 1861.48 0.15 279.22 "C"
Cost for 96 square Inch 2140.70 "Y"= (X+C)
Cost for 1 square Inch 22.30 "Z"=(Y+D)
say Rs. 22.00 Sq. inch
MR 2 Providing and fixing factory made prelaminated flush door
comprises core of block board construction with frame of 1st
class hard wood and well matched commercial 3 ply veneering
with vertical grains or cross bands and face veneers on both faces
of shutters conforming to IS: 2202 (part 1) followed with
machine pressed 1.00mm thick lamination on both faces of
shutter in required finish and shade with suitable adhesive
including providing and fixing 3 to 5 mm thick teak lipping along
edges of shutter all complete as per direction of Engineer-in-
a) 35 mm thick including ISI marked Stainless Steel butt hinges
(heavy weight) 100mm x 60mm x 2.5mm with necessary screws.
Details of cost for 2.20 sqm
Analysis of Rate for Civil Items Derived from DSR 2021
35 mm thick factory made prelaminated flush door comprises Sqm 2.20 4200.00 6820.00
core of block board construction with machine pressed 1.00mm
thick lamination on both faces of shutter including providing and
fixing 3 to 5 mm thick teak lipping along edges of shutter.
Carriage of door LS 200.00
Stainless steel butt hinges (heavy weight) 100x60x2.5 mm IS : 12817 marked
Carriage of material L.S. 200.00
Stainless steel screws 40 mm 100 Nos. 0.48 220.00 105.60
For fixing shutter and fittings
Carpenter 1st class Day 0.50 750.00 375.00
Sundries LS 75.00
TOTAL 8285.60 W
Add 1 % Water charges on "W" 82.86
TOTAL 8368.46 X
Add GST on "X" (multiplying factor 0.1405) 1176.00
TOTAL 9544.46 Y
Add 15% CPOH on "Y" 1431.67
TOTAL 10976.13 Z
Add Cess @ 1% on "Z" 109.76
Cost for 2.20 Sqm 11085.89
Cost for 1 Sqm 5039.04
Say Rs. 5040.00
MR 3 Providing & fixing G.I. chicken wire mesh of nominal size upto
20mm having 24 gauge thick with G.I. nails etc. to wall surface
of dissmilar material viz RCC and brick work etc.all complete.
Detail of cost for 10.00 Sqm. (Ref.; as per LMR)
Description Unit Quantity Rate Amount
M.S. chicken wire mesh of nominal size 12 mm i/c 5% wastage Sqm 10.50 139.88 1468.74
Carriage of material & fixing charges LS 15.00 2.00 30.00
Sundries (nails, binding wire etc.) LS 10.00 2.00 20.00
Total 1498.74 "W"
Add for water charges @ 1% % 1498.74 0.01 14.99
Total 1513.73 "X"
Add GST (@12%) on "X" (multiplying factor 0.1405) % 1513.73 0.1405 212.68
Total 1726.41 "Y"
Total 1985.37 "Z"
Cost for 10 Sqm 2005.22
Cost for 1 Metre 200.50
12.20 & Extra for providing and laying pressed clay tiles (as per
11.8 approved pattern 20 mm nominal thickness of approved
(Modified) size with 3mm PVC spacer) on roofs jointed with cement
mortar 1:4 (1 cement : 4 coarse sand) mixed with 2%
integral water proofing compound and finished neat
complete instead of making chequers of approved pattern
(300mm x 300mm square 3mm deep) in waterproofing
item (Rate is over item no. 22.7.1)
Detail of cost for 10 Sqm (Ref.: DAR-II item No. 22.7.1)
Description Unit Quantity Rate Amount
A. Cost of pressed clay tiles 20mm nominal thickness
7266 Pressed clay tiles 20 mm thick 1000 Nos. 0.16 8000.00 1280.00
250 x 250 mm size
2207 Carriage of Brick tiles 1000 Nos. 0.16 262.29 41.97
3.9 Cement mortar 1 : 4 (1 cement : 4 coarse sand) Cum 0.037 4355.20 161.14
Rate as per Item Number 3.9 of
1213 Integral water proofing compound kg 0.01 35.00 0.35
2% by weight of cement
9999 Sundries (3mm PVC tile spacer etc.) LS 100.00 2.12 212.00
123 Mason (brick layer) 1st class Day 0.60 784.00 470.40
Analysis of Rate for Civil Items Derived from DSR 2021
Total 3870.42 "W"
Add for water charges @ 1% on "W" % 3870.42 0.01 38.70
Total 3909.12 "X"
Add GST on "X" (multiplying factor 0.1405) 3747.98 0.1405 526.59
Total 4435.71 "Y"
Total 5076.90 "Z"
Cost for 10.00 Sqm 5126.06
Cost for 1.00 Sqm 512.61
say Rs. 512.60 "P"
Cost of making chequers of approved pattern (300mm x 300mm
square 3mm deep)
rate same as per DAR Item No. 11.8
Cost for 1 Sqm Rs. 63.20 "Q"
Hence rate for item analysed "P" - "Q" Rs. 449.40
10.12 (M) Providing and fixing steel beading of size 10 x 10 x 1.6
mm (box type), approved shape and section with screws in
steel doors, windows, ventilators, composite units and
M.S. tubular frame erc.
Details of cost
Detail of cost for 1 metre beading for
doors, windows, Ventilators,
composit units and M.S. tubular frame erc.
Description Unit Quantity Rate Amount
1143 Steel beading size 10 x 10 x 1.6 mm (box type) Each 1.00 27.00 27.00
9999 Applying priming coat LS 0.46 2.00 0.92
9999 Fixing charges LS 3.01 2.00 6.02
Add for water charges @ 1% on "W" % 33.94 0.01 0.34 "A"
Add 12% GST applicable on work contract, by reversible 34.28 0.1405 4.82 "B"
method (multiplying factor 0.1405)
Add for contractor's profit & over-heads @ 15% on "X "C"
Add for Labour Cess @ 1% on "Y" % 44.97 0.01 0.45 "D"
Cost for 1.00 Metre Rs. 45.42 "Z"=(Y+D)
MR 8 Graffiti painting on wall as approved logo of Eklavya
(EMRS) by high gloss acrylic colour before making logo,
prepare the surface clean, fill POP in voids, apply 1mm
white birla putty and primer including material, labour and
T&P etc. all complete under instruction of Engineer-in-
DSR ITEM White cement based putty of average thickness 1 mm Sqm 10.00 115.15 1151.50
13.48 100% Premium acrylic additives exterior paint litre 1.43 270.00 386.10
Acrylic Exterior Primer litre 0.9 100.00 90.00
Carriage of material L.S. 1.56 2.00 3.12
Painter for Graffiti Painting day 0.45 2500.00 1125.00
Brushes, sand paper etc. L.S 7.15 50.00 357.50
DSR ITEM 10% P.O.P. filling of total area on lumsum basis Sqm 1.00 196.70 196.70 B
DSR ITEM Scaffolding for painting work Sqm 10.00 257.95 2579.50 C
TOTAL 6570.07 W
Analysis of Rate for Civil Items Derived from DSR 2021
Add 1 % Water charges on "W" except A, B & C 26.42
TOTAL 6596.49 X
Add GST on "X" (multiplying factor 0.1405) except A, B & C 374.97
TOTAL 6971.46 Y
Add 15% CPOH on "Y" except A, B & C 456.56
TOTAL 7428.02 Z
Add Cess @ 1% on "Z" except A, B & C 35.00
Cost for 10 Sqm 7463.03
Cost for 1 Sqm 746.30
Say Rs. 750.00
Derived Providing and placing in position 400 micron thick low
from basic density polyethylen (LDPE) black sheet under base of
rates of RCC grade slab. The overlaps at end and side joints of
DSR 2021 PVC sheet shall not be less than 100mm wide and shall be
pasted to each other with bitumen @ 1.7 kg/sqm. (Note:
Superfical area of sheet shall be measured for payment)
Details of cost for 10 sqm
3002 400 micron thick low density polyethylen (LDPE) black Sqm 11 45 495
sheet i/c 5% for wastage and 5% for overlap
9999 Sundries (bitume etc.) L.S. 50 2.12 106
Carriage of PVC sheet L.S. 20 2.12 42.4
TOTAL 813.28 "W"
Add 1 % Water charges on "W" 0.25 8.13
TOTAL 821.41 "X"
Add GST on "X" (multiplying factor 0.1405) 115.41
TOTAL 936.82 "Y"
Add 15% CPOH on "Y" 140.52
Add Cess @ 1% on "Z" 10.77 "Z"
Cost for 10 Sqm 1088.11
Cost for 1 Sqm 108.81
Say Rs. 108.80
Providing and fixing oxidised M.S. casement window
fastener with necessary screws etc. complete.
(copper oxidized as per IS: 1378)
MR 6 a) 100 mm weighing not less than 100 gms
Deraived as per Item No. 9.85/ DAR-1/2021
Description Unit Quantity Rate Amount
Detail of cost for 10 Nos
M.S. casement window fastener with screws each 10 17 170
Carriage of material LS 0.91 2.12 1.93
1st class carpenter Day 0.1 784 78.4
TOTAL (W) W ₹ 250.33
Add 1 % Water charges on "W" A ₹ 2.50
Total (X) X = W+A ₹ 252.83
Add 12% GST applicable on work contract,by B ₹ 35.52
reversible method (multiplying factor 0.1405)
TOTAL (Y) Y= X+B ₹ 288.36
Add 15% CPOH on "Y" C ₹ 43.25
TOTAL (Z) Z=Y+C ₹ 331.61
Add Cess @ 1% on "Z" ₹ 3.32
Cost of 10 Nos. ₹ 334.92
Cost of 1 No. ₹ 33.50
Analysis of Rate for Civil Items Derived from DSR 2021
MR 7 Supplying, making & fixing of Eklavya Archery logo
made of 18mm thick WPC BOARD as per image on
front wall of school building left & right side inclding
all fixtures and two coats of painting etc all complete
as per the direction of Engineer in charge. a) of outer
dimension 5.5 mtr height & 3.5 mtr width
Description Unit Quantity Rate Amount
Making fitting and fixing of Eklavya Archery logo set 1.00 58400.00 ₹ 58,400.00
inclding all fixtures and two coats of painting etc all
Add 1 % Water charges on "W" A ₹ 584.00
Add 12% GST applicable on work contract,by B ₹ 8,287.25
reversible method (multiplying factor 0.1405)
TOTAL (Y) Y= X+B ₹ 67,271.25
Add 15% CPOH on "Y" C ₹ 10,090.69
TOTAL (Z) Z=Y+C ₹ 77,361.94
Add Cess @ 1% on "Z" ₹ 773.62
MR 8 Supplying, making & fixing of Eklavya Archery logo
made of 18mm thick WPC BOARD as per image on
front wall of main gate inclding all fixtures and two
coats of painting etc all complete as per the direction
of Engineer in charge. a) of outer dimension 3 m
height & 1.5 m width
Description Unit Quantity Rate Amount
Making fitting and fixing of Eklavya Archery logo set 1.00 18200.00 ₹ 18,200.00
inclding all fixtures and two coats of painting etc all
Add 1 % Water charges on "W" A ₹ 182.00
Add 12% GST applicable on work contract,by
reversible method (multiplying factor 0.1405)
TOTAL (Y) Y= X+B ₹ 20,964.67
Add 15% CPOH on "Y" C ₹ 3,144.70
TOTAL (Z) Z=Y+C ₹ 24,109.37
Add Cess @ 1% on "Z" ₹ 241.09
aoc.pdf
Download all tender documents and submit your bid