Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹4.6 LAccepted-AOC 268 KARGALI BAZAR BERMO BOKARO 829104 JHARKHAND | BOKARO | JHARKHAND | 829104 | L-1 | Accepted-AOC Deposited performance security money | |
| 2 | L-2₹4.8 L+₹10,266 (2.21%)Rejected-Finance 268 KARGALI BAZAR BERMO BOKARO 829104 JHARKHAND | BOKARO | JHARKHAND | 829104 | L-2 | Rejected-Finance Not Evaluated | |
| 3 | Rejected-Technical 01 MADHU BHAWAN FIRST FLOOR FLATE NO 01 NAWADIH DHANBAD JHARKHAND 828130 | DHANBAD | JHARKHAND | 828130 | - | Rejected-Technical Technically disqualified |
| Sl No | Description | Qty | Unit | RAJA ELECTRICAL WORKS L1 | M/s Kiran Electrical works L2 |
|---|---|---|---|---|---|
| 1.00 | Replacement of archute with complete on off mechanism for 3.3 KV grade starter. | 1 | No. | 40,000 ₹40,000 Lowest | 40,000 ₹40,000 Lowest |
| 2.00 | Supply and providing of Power pack unit 110V AC/DC. | 1 | No. | 8,500 ₹8,500 Lowest | 9,000 ₹9,000 |
| 3.00 | Replacement of Isolater on off air break assembly complete set. | 1 | No. | 35,000 ₹35,000 Lowest | 35,000 ₹35,000 Lowest |
| 4.00 | Replacement & fixing of tripping and closing coil. | 2 | Set | 4,000 ₹8,000 Lowest | 4,000 ₹8,000 Lowest |
| 5.00 | Replacement of Ampere meter and voltmeter | 2 | Set | 3,000 ₹6,000 Lowest | 3,000 ₹6,000 Lowest |
| 6.00 | Rectification of control circuit using lugs clips and washer etc. | 1 | Set | 5,000 ₹5,000 Lowest | 5,000 ₹5,000 Lowest |
| 7.00 | Suppy and providing of copper flexible strip 800amps capacity of approx size 4 ft length 5mm thickness. | 6 | Each | 1,500 ₹9,000 Lowest | 1,500 ₹9,000 Lowest |
| 8.00 | complete rewiring with 2.5sqmm copper flexible fireproof pvc wire of 1100V | 1 | Job | 6,000 ₹6,000 Lowest | 6,000 ₹6,000 Lowest |
| 9.00 | Replacement & fixing of current transformer 200/100-5-5 | 3 | No. | 9,000 ₹27,000 Lowest | 10,000 ₹30,000 |
| 10.00 | Replacement of roller bearing | 3 | No. | 2,000 ₹6,000 Lowest | 2,000 ₹6,000 Lowest |
Tender Value
₹4.3 L
EMD Value
₹5,400
Closing Date
31 Jul 2025, 11:00 amClosed
SO(EnM), BnK
GM Office, BnK Area, Bermo, Bokaro, Jharkhand.
Repairing n Overhauling of 01 no. HT Starter and 02 nos of HT Switchgears namely (A) Repairing of one no 3.3 kv grade HT starter sl no 0991 for control and Protection of 1000 gpm pump motor (B) Repairing of one no 11kV grade 400 amps
2025_CCL_339851_5
SO(EnM)/e-tender/25-26/06
Open Tender
Electrical and Maintenance Works
Item Rate
15 days
IWSP
As per NIT
2 documents required · 2 mandatory
₹5,400
13 Oct 2025
19 Jul 2025
1 Aug 2025
19 Jul 2025
31 Jul 2025
21 Jul 2025
19 Jul 2025 - 26 Jul 2025
Amount
Replacement of archute with complete on off mechanism for 3.3 KV grade starter.
Supply and providing of Power pack unit 110V AC/DC.
Replacement of Isolater on off air break assembly complete set.
Replacement & fixing of tripping and closing coil.
Replacement of Ampere meter and voltmeter
Rectification of control circuit using lugs clips and washer etc.
Suppy and providing of copper flexible strip 800amps capacity of approx size 4 ft length 5mm thickness.
complete rewiring with 2.5sqmm copper flexible fireproof pvc wire of 1100V
Replacement & fixing of current transformer 200/100-5-5
Replacement of roller bearing
Replacement and fixing of fixed and moving contact.
Replacement and fixing of tripping and closing coil
Supply and providing of HRC fuse with base.
Suppy and providing of Power pack unit 110V AC/DC.
Replacement of top bushing insulator for incoming and out going bushing insulator 11KV grade 630amps with complete stud assembly
Complete re-wiring with 2.5sqmm copper flexible fireproof pvc wire of 1100V
.Replacement & fixing of current transformer 200/100-5-5
Replacement of roller bearing
Replacement and fixing of fixed and moving contact.
Replacement and fixing of tripping and closing coil
Replacement of Ampere meter and voltmeter
Replacement of top bushing insulator for incoming and out going bushing insulator 11KV grade 630amps with complete stud assembly
Supply and providing of HRC fuse with base.
Supply and prooviding of tank rose contact.
Rectification of control circuit using lugs clips and washer etc.
Replacement of potential transformer 11KV/110V
Supervision and incidental charges @10%
Total impact of GST for the purpose of CTC
M/s Kiran Electrical works (BID ID -1171892)
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .