Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹39.6 LAccepted-AOC 114 BARH CHONDI TOWN BARH DISTT PATNA BIHAR PIN 803213 | PATNA | BIHAR | 803213 | L1 | Accepted-AOC L1 bidder lowest | |
| 2 | L2₹42.7 L+₹2.9 L (7.26%)Rejected-Finance 1257 SCHEME NO 5 NEAR HB COLLEGE VIJAY NAGAR JABALPUR MP PIN 482002 | JABALPUR | MADHYA PRADESH | 482002 | L2 | Rejected-Finance Other than L1 | |
| 3 | L3₹45.8 L+₹6.0 L (15.1%)Rejected-Finance 1 SANCHAR NAGAR NEAR KRISHI UPAJ MANDI DAMOH ROAD JABALPUR M P | JABALPUR | MADHYA PRADESH | 482001 | L3 | Rejected-Finance Other than L1 | |
| 4 | L4₹46.9 L+₹7.1 L (17.9%)Rejected-Finance | L4 | Rejected-Finance Other than L1 | |
| 5 | L5₹47.0 L+₹7.3 L (18.3%)Rejected-Finance 261 NAPIER TOWN DR BARAT ROAD JABALPUR MP 482001 | JABALPUR | JABALPUR | MADHYA PRADESH | 482001 | L5 | Rejected-Finance Other than L1 |
Tender Value
Refer Docs
EMD Value
₹98,000
Closing Date
14 Jul 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE (West) Jabalpur
Garrison Engineer (West) Jabalpur Supply Marg Post Box No. 54 Jabalpur Cantt-482001 (MP)
PROVN OF CERTAIN MINOR AND REV WORKS IN THE AREA OF AGE B/R-I, B/R-III AND AGE E/M E/S UNDER GE (WEST) JABALPUR
2021_MES_455811_1
8340/E8
Open Tender
Civil Works
Item Rate
180 days
GE (West) Jabalpur
As per Tender documents
5 documents required · 5 mandatory
₹500
GE (West) Jabalpur
₹98,000
20 Jul 2021
30 Jun 2021
16 Jul 2021
30 Jun 2021
14 Jul 2021
7 Jul 2021
1 Jul 2021 - 6 Jul 2021
60 days
Amount
Demolition of cement conc. (Unreinforced) in ground floor n exc 15 cm thick complete all as specified and directed.
Demolition of brick work built in cement mortar including all quoins, arches, pillars etc complete all as specified and directed.
Demolition of reinforced concrete of any description and in any position not otherwise specifically provided for including reinforcement cut as required to facilliate demolition complete all as specified and directed.
Surace excavation n. exc 30 cm deep and averaging 15cm deep and getting out in soft/loose soil.
Excavation in trenches not exceeding 1.5m wide and not exceeding 1.5m depth for foundation etc or for shafts, wells cesspits manholes pier holes etc not exceeding 10 sqm on plan and not exceeding 1.5 m depth in any type of soil etc complete all as specif
Supply and laying Moorum/red bajri filling in floors or pavings, laid in layers n exc. 15 cm thick, spread, levelled and rammed including watering complete all as specified and directed.
Supply and laying Hardcore of Broken stone or boulders gauge n exc. 63mm, deposited, spread and levelled in layers n exc. 15 cm thick, watered and rammed to a true surface complete all as specified and directed.
M & L for Plain cement concrete (1:4:8) type D-2 using 40mm graded stone aggregate as in foundation filling and mass concrete complete all as specified and directed.
M&L for RCC (Design mix) M-20 using 20 mm graded stone aggregates as in foundations, including rafts, footings, foundation beams, plinth beams, bases for columns, etc, basement slabs, under reamed piles and mass concrete complete all as specified and directed
M&L for RCC (Design mix) M-20 using 20 mm graded stone aggregates as in columns, pillars, piers, posts and struts and similar work complete all as specified and directed.
M&L for RCC (Design mix) M-20 using 20 mm graded stone aggregates as in beam, cantilevers, bressummers, lintels over 1.5 m span and similar work complete all as specified and directed.
Use and waste of formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter complete all as specified and directed.
Use and waste of Formwork to sides of pillars, posts, struts, piers, columns complete all as specified and directed.
Use and waste of formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressum-mers, lintels, cantilevers, shelves including supports, overhangs complete all as specified and directed.
S&F TMT bar 10mm dia and over cut to length bent to shape required including cranking, bending spirally for hoping for columns hooking ends and binding with & including Mild Steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed.
S&F TMT bar 5mm dia and over upto and including 10mm dia as in stirrups, spacers & binders cut to length bent to shape required including cranking, bending spirally for hoping for columns hooking ends and binding with & including Mild Steel wire (annealed) not less than 0.9mm dia or securing with clips complete
M&L for Brick work using fly ash bricks straight or curved on plan exc 6m mean radius built in cement mortar 1:6 complete all as specified and directed.
Returning filling in including spreading leveling, watering and well ramming in layers not exc 25 cm in soft/loose soil complete all as specified and directed.
Removing excavated material exc 1.50 KM & n.exc 5 KM and depositing where directed at a level n.exc 1.5 M above from starting point complete all as specified and directed.
M&L for PCC 1:2:4 type B-1 (using 20 mm graded stone aggregate) in lintels upto 1.5 clear span, cills, steps, seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers ,apex stones, bed plates, water troughs and the like including use of formwork (straight or curved) ,including weathering, slightly rounded or chamfered angles and throating, all as specified and as directed (Note :-reinforcement where provided shall be measured and paid seprately)
M&L for rendering 15mm thick in two layers (10 mm thick in CM 1:6 and 5 mm thick in CM 1:4 on external surface) with water proofing compound as per manufacturar insturction on fair faces of brick work or concrete surfaces of wall and finished even and fair complete all as specified and directed. (Note : WPC will be measured and paid seperately)
M & L for 20mm thick granite (of any type) work Granite (of any type) work (table rubbed and polished) for wall lining (veneering to wall) 12mm thick in cement mortar (1:3) and pointing with white cement (1:2) using marble dust with admixture of pigment to match with shade of granite complete all as specified and directed.
M & L for 100mm thick Cement concrete type B-2, 1:2:4, using 40mm graded stone aggregate in hardstanding complete all as specified and directed.
S&F for ENDURA out door tiles 30 cm x 30 cm x 12 mm thick rubberised mould set, jointed and pointed in neat cement slurry as in floors fixed over and including screed bed 15mm thick in CM 1:6 etc of Make H & R Johnson, Brand-Endura designer digital series
S&F Machine pressed precast concrete interlocking coloured paver block rubberised any shape and size confirming to IS 15658-2006 of 80mm thickness, M- 40 Grade fixed over and inlcuding 50mm thick sand coushing complete all as specified and directed.
Dismantling structural steel work including doors, gates but excluding framed truss etc. complete all as specified and directed.
Supply and fixing for framed work as in doors or gates of angle or other section with gusset plates, rails, braces, etc., complete, drilled for fixing of steel sheeting or other covering. Doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging; also fastening of grade Fe 410 -W (GdeE- 250) qualityAand fixing complete all as specified and directed.
M&L for two coat of syntetic enamel paint over new steel surface of any description over 10cm in width or grith not otherwise described over one coat red oxide primer incl preparation of surfaces complete all as specified and directed.
M&L for Preparation of newly plastered surfaces of walls and applying two coats of cement base paint over a coat of primer etc complete all as specified and directed.
S&F 2mm thick fibre glass reinforced translucent corrugated sheeting with two corrugations side lap fixed with coach screw and washer in roof, wall etc complete all as specified and directed.
M&L for RCC (Design mix) M-25 using 20 mm graded stone aggregates Slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like complete all as specified and directed.
Use and waste of formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick complete all as specified and directed.
S&F steel work in tubular trusses including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to I. S 1161-1979 grade St.-240 etc complete all as specified and directed.
S&F Mild steel nits bolts. purpose made. with hexagonal or square head one end and screwed the other, or screwed both ends; each screwed end to be fitted with washers and one hexagonal or square nut. Exc 30cm long etc complete all as speified and directed.
S&F Plates (plain or chequered) channels, square cut or notched (ordinary and counter sunk) forming holes, without any attachment etc all as speified and directed
S&F for painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws all as specified and direted.
S&F Pre-painted galvatume aluminium zinc coating GI based plain steel sheet 0.5mm thick of an colour having tensile strength of 550 Mpa as in roof covering /cladding to wall, fixed with self tapping screws as specified and directed
M&L for 40mm thick PCC 1:2:4 type B-0 using 12.50mm graded stone aggregate as in floors finish etc all as specified and directed.
M&L for Vitrified Ceramic tiles light shade 10 mm thick (square/ rectangular) polished, area of each tiles exceeding 0.42 sqm but not exceeding 1.00 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white cement fixed over and including 15 mm thick screed bed in CM (1:6) etc complete all as specified and directed.
Material and labour for Glazed ceramic tiles of size 350x 250x 7mm/ 450X 350X 7mm thick in vertical surfaces such as dado/ skirting etc set and jointed in neat cement slurry and pointed in white or coloured cement to match fixed over and including 10mm thick rendering in CM 1:4 etc all as specified
M & L for Granite (Black/Ruby Red ) work (table rubbed and polished) 20 mm thick in cooking platforms bedded and jointed with grey cement slurry and pointed to match the shade of granite stone including grinding and polishing complete fixed over and including screed bed 15 mm thick in CM 1 : 6 etc complete all as specified and directed.
S&F Framed work such as grills, gratings etc., with ends of bars shouldered and/or riveted, or forget into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe 410-0 or Fe 310-0 complete all as specified and directed.
S&F rolled sections as in main and cross beams, hip and jack rafters; purlins where connected to a common rafters, fixed with angle cleats or other connecting plates of Gde fe 410-0 or fe 250-0 etc all as specified and directed.
S&F hand rails, half rounded or other stock section or core for wooden hand rail straight portion, drilled and counter sunk for balusters, nosing to steps including embeding in concrete and screwing etc wind ties for roof including securing bolts; posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire etc; flat iron fillets (for securing wire mesh etc,) including all necessary drilling bolting or riveting, etc and similar work conforming to Fe410-0 or Fe 310-0 complete all as specified and directed.
M&L for 1st class hard wood handrails of size 100X75mm, rounded or shaped with splayed faces in straight lengths and fixed complete all as speified and direted.
M&L for PCC 1:3:6, 75mm thick in type C-2 (using 40mmgraded aggregate) as in plinth protection etc all as specified and directed.
Dismantling of wall and ceiling boards (fibre, pulp, insulation, etc.) or insulation boards/slabs/ blankets, any thickness, including cover fillets complete all as specified and directed.
M&L for preparation of old decorated surfaces of wall and applying two coat of OBD on 2mm thick birla wall care putty over a coat of primer on walls including removing of completely existing reatment on wall surface etc complete all as specified and directed.
Taking down chowkats or frames with shutters (without taking off shutters from the frames) not exc. 1.5 sqm each complete all as specified and directed.
M&L for Rendering 15mm thick in Cement Mortar 1:6 on fair faces of Brick Walls or on Concrete Surfaces, finished Even and Smooth,without using extra cement complete all as specified and as directed.
M&L for preparation of new surfaces of wall and applying two coat of OBD on 2mm thick birla wall care putty over a coat of primer on walls etc complete all as specified and directed.
M&L for acoustic wall/ceiling panelling consisting of 16mm thick MDF sheet inclusive of solvent cement and fixing at site on frame including all necessary fittings frame etc arrangements as per specifications and as directed by EIC of . Make: ARMSTRONG or equivalent approved by GE.
Material and labour for applying three coats of an acrylic elastomeric coating Dr. Fixit on prepared concrete surfaces as per given following procedure stagewise :- (a) Removing all the unwanted particles from the surfaces. Any previous growth of Algea, fungus shall also be removed from surface. The subtract must be sound and if any repairsto be carried out use suitable Dr. Fixit repair matterial (b) Providing and applying a primer coat of (Dr. Fixit ) Primeseal diluting two parts primer with one part water over the surface. (c) Providing and applying First coat of Dr. Fixit new coat over the primed surface. (d ) Providing and applying glass fibre mesh (2mm X 2mm - 40GsM) between the first and second coat as reinforcement to strengthen the coating shall achieve a Dr Fixit about 1mm in Three coats on prepared surfaces. (e) Providing and applying Third coat of Dr. Fixit (New Coat).
Supply and fixing Single phase wall mounted remote controled fan heavy duty AC 230 volts 400 mm sweep, metallic body complete including electric connection with twin core copper wire for wall mounted fan, nut, clamp & bolt etc complete all as specified and as directed.Make: Bajaj,Havells
Supply and Fixing socket outlet 5 pin, 6 Amps flush type 230 volts AC complete all as specified and as directed
S & F Sheet metal enclosure DBs Single Pole and Neutral 8 way with 200 Amps rated bus bar 240 volts single pole and neutral complete double door including MCB SPN -16 Amp 1 nos and SP - 10 Amp 5 Nos complete all as specified and directed by Engineer in charge of Make- Legrand,L&T,HPL
M&L for Sub Main Wiring with two single core PVC insulated cable of size 4.0 Sqmm multistranded copper conductor drawing into and including concealed rigid non-metallic PVC conduit, medium grade not less than 25mm dia with all conduit fitting,fixing accessories and 2.5 Sqmm multistrand copper conductor cable as continuous earth wire complete all as specified and directed by Engineer in charge Note :- Two Nos of 4.0 Sqmm Wire and one nos of 2.5 Sqmm Earth wire in One RM length Measured as one unit length.
Earthing complete with galvanised steel earth plate electrode 60 cm x60 cm x 6 mm thick buried directly in ground ,(Earth pit not less than 2.25 meter deep below ground level) with top edge of plate not less than 1.5 meter below normal ground level ,connected to and including galvanised iron earth wire 4 mm dia by means of nut, bolts, check nuts and washers of galvanised iron or steel complete all as specified and directed including testing on completion including the material and labour of the following : - (a) Excavation and earth work for drilling hole for electrode in any type of Soil. (b) PCC pit in cement concrete 1:2:4 type B-1, Pre cast RCC cover with suitable handle 40 mm thick in PCC 1:2:4 type B-1, reinforced with welded steel wire fabric weighing not less than1.87 Kg/ Sq meter. (c) Funnel with watering pipe of GI 20 mm nominal bore light grade and lugs etc complete all as specified and directed (d) 15 mm nominal bore medium grade GI protection pipe 5 meter long for protection of earthing lead complete all as specified and directed. (e) Requisite quantity of common salt and charcoal. (f) Testing of earthing.
S&F Earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required 4mm dia galvanised iron or steel wire all as specified and directed.
Material & Labour Sub main wiring with four single core PVC Insulated cable four run of size 6.0 Sqmm multi-strand copper conductor FRLS cable 1100 volts grade drawing with PVC conduit, medium grade not less than 32 mm dia with all conduit accessories and two run of 4.0 Sqmm multi-strand copper conductor FRLS cable as continuous earth wire including making good disturbed surface to match existing complete all as specified & directed. Note : - four run of 6.0 Sqmm & two run of 4.00 Sqmm cable shall be measured as one unit run.
Material & Labour Sub main wiring with four single core PVC Insulated cable four run of size 4.0 Sqmm multi-strand copper conductor FRLS cable 1100 volts grade drawing with PVC conduit, medium grade not less than 25 mm dia with all conduit accessories and two run of 2.5 Sqmm multi-strand copper conductor FRLS cable as continuous earth wire including making good disturbed surface to match existing complete all as specified & directed. Note : - four run of 4.0 Sqmm & two run of 2.50 Sqmm cable shall be measured as one unit run.
M&L for sheet steel enclosure 1.6mm thick with hylum sheet 3 mm thick with providing 3/6 pin 5/15 amps switch socket combination -3 nos with making connection with 2.5 sqmm copper wire with MCB SPN 30 amps with sheet steel enclosure as incoming all as required and directed at site and making good the disturbed surfaces to match with the existing surfaces complete all as specified and directed by Engineer in charge.
S&F sheet steel enclouser distribution boards, double door factory made TPN Vertical 4 way 3 phase 415 volts 4 way with 200 amps rating copper bus bar and PVC insulated copper jumpers of suitable size from the MCCB to the out going circuits including provision one incoming MCCB 100 amps and MCB TP 63 A -02 Nos,MCB SP -04 Nos circuits comprising of 3 phase 4 wire of suitable rating all as specified and directed.
S & F sheet metal enclosure MCB DB 4 way Vertical type with 200 Amps rated bus bar 415 volts double door with magnitic locking system including necessary provision for inserting the DBs in wall by cutting the brick/stone masonary etc and making good of distrubed surface to match with existing colour of wall complete all as specified and as directed.
S & F MCB TPN 415 volts 63 Amps . complete all as specified and directed by engineer in charge.
S & F MCB single pole upto upto 40 Amps . complete all as specified and directed by engineer in charge.
Supply , laying and testing cable XLPE insulated , screened, PVC bedded , galvanized , steel strip or wire armoured, electric power cab les ( Heavy duty ) 1100 volts grade with stranded aluminium conductor of size 4.0 core 25 Sqmm necessary clamping and fixing accessories complete all as specified and directed by Engineer in charge.
Supply , laying and testing cable XLPE insulated , screened, PVC bedded , galvanized , steel strip or wire armoured, electric power cab les ( Heavy duty ) 1100 volts grade with stranded aluminium conductor of size 4.0 core 10 Sqmm necessary clamping and fixing accessories complete all as specified and directed by Engineer in charge.
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 35.0 sq mm 3.5 core complete all as specified and as directed.Make- Polycab,Havells,Gloster
Supply and laying XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 2 core 10 Sqmm complete all as specified and directed by Engineer in charge Make- Polycab,Havells,Gloster
Supply,laying & fixing double wall corrugated (DWC) pipes made of high density polythyline (HDPE) with all accessories i.e. all type of joints,Sockets,Elbows,bends and End caps etc.. all as specified and directed by Engr in Charge.of size 50 mm outer dia and 38 mm inner dia of Make;-Telerex/Tirupati or E-in-C approved make
S&F GI Tubes,of size 40 mm dia light grade, galvanised, with all fitting , laid in trenches for protection of cable in road /drain crossing complete all as specified and as directed.
Earthing complete with galvanised steel earthpipe of 3000mm long and 65mmouter x50mm inner dia laid in ground by drilling in the ground as required with filling the back fill compound complete with all as required and directed with 32x6 mm GI strip up to testing point and making the earth pit of PCC as per sample as required at site and testing after completion complete all as specified and directed.Make HP earth or eqvt
Supply & fix sheet metal enclosure box in single pole and neutral fitted with two pin and earth plug and socket complete with one single pole MCB 240 volt 20 Amps 'C' series of suitable rating complete all as specified and directed Make: LEGRAND,HAVELLS,L&T
Material & Labour for Sub main wiring with two single core PVC Insulated cable two run of size 6.0 Sqmm multi-strand copper conductor FRLS cable 1100 volts grade drawing in and including PVC conduit, medium grade not less than 25 mm dia with all conduit accessories and one run of 4.0 Sqmm multi-strand copper conductor FRLS cable as continuous earth wire complete all as specified and directed. Note : - Two run of 6.0 Sqmm & one run of 4.0 Sqmm cable shall be measured as one unit run
S&F of sheet steel enclousure distribution boards, double door factory made TPN Vertical 4 way 3 phase 415 volts 4 way with 200 amps rating copper bus bar and PVC insulated copper jumpers of suitable size from the MCCB to the out going circuits one incoming MCCB 160 amps 25 KA 4 pole all as specified and directed.Make: Legrand,Hpl,havells
Supply & fixing MCB SPN up to 40 amps 240 volts AC 10 KA breaking capacity 'c' series 'ISI Marked and conforming to IS 8828/IEC 60898-1 complete all as specified and directed.Make: Legrand,Hpl,havells
Supply & fixing MCB DB SPN Distribution box double door of protection grade IP 43 in fine powder coated matt finish with best CRCA sheet fitted with shrouded neutral insulated pin type copper bus bar Din rail earth bar of 8 way conforming to IS 13032 & 8623 complete all as specified and directed.Make: Legrand,Hpl,havells
M&L for Point wiring with PVC insulated 1.5 sq mm multi stranded copper conductor cable 1100 volts grade drawn into and including concealed / on ;surface PVC conduit not less than 20mm (ISI marked) including all fitting and fixing accessories including sunk in cast iron/pressed steel terminal boxes duly painted with two coats of antcororosive paint inside and two coats of aluminium paint outside , 2.8mm thick hylam brand laminated white bakelite sheet cover for mounting of switches, sockets, fan regulators etc and PVC insulated 1.5 Sqmm multistranded copper conductor cable as earth wire and making good the disturbed surfaces to match with the existing surfaces complete all as specified and directed by Engineer in charge.
(a) One light/fan point controlled by one switch.
(b) One socket point controlled by one switch on Same board.
(c) One socket point controlled by one switch on Independent board.
Description ditto all as per above items but with 1100 volts grade copper standard conductor cable of size 2.5Sqmm with 1.5Sqmm multi stranded copper conductor PVC for 3 pin switch socket outlet15 Amp independent board complete all as specified and directed by Engineer in charge .
M&L for Switch piano flush type AC 230 volts 5 Amps single pole one way complete all as specified and directed by Engineer in charge.
M&L for Socket outlet 3 pin, 5 Amps and AC 230 volts flush type complete all as specified and directed by Engineer in charge
M&L for Switch socket combination 3 pin 5 and 15 Amps AC 230 volts flush type complete all as specified and directed by Engineer in charge
M&L for Ceiling rose surface bakelite 65 mm x50 mm three terminal AC 230 volts flush type complete all as specified and directed by Engineer in charge
S & F fan regulator rotary type step 120/280 watt capacity of polycarbonite complete all as specified and directed by Engineer in charge.
S&F lamp holder PVC/Polycarbonate type body, with back plate for batten fitting complete all as specified and directed by Engineer in charge.
S & F LED lamp 9 watt capacity complete all as specified and directed by Engineer in charge.
Supply & fix LED Security Light Luminaire 30 watt 6000K with .high power LED cool white,CRI 75,+/- 5% supply voltage 220/240/50 Hz, light engine driver base.pole adapter,powder coated pressure die cast aluminium with heat resistant toughened glass with lens GI pipe 40 mm dia medium Grade not less than with 1.2 m.long in any shape with 2 nos of pole fitting clamps made out of MS flat , nuts and bolts and painting with aluminium paint. complete all as specified and as directed.Make:crompton ASTRANEO LSTS-30-CDL-M or equivalent in HAVELLS or C&S
Supply & Fixing Smart bright Batten Series, LED luminaire using LEDs 22 watt 110 LM/watt with diffuser which ensures uniform distribution and comfort batten series features latest LEDs and delivers consistent light output, stable color start Extruded Aluminum housing, Energy efficient, Flicker free start Inbuilt driver unit Suitable for wall and ceiling mounting using brackets (supplied along with The Luminaire has been tested as per Standard Specification IEC 60598-2-1 / IS: 10322(Parts/Secl), report has established conformity of the product(s) to the requirements of the Standard/Specification Make : Philips Cat part BN 021 LED 22S 6500/4000 PSU GR SI or equivalent
S & F LED Mirror light fitting 2 ft TL 5 -10/12 watt complete all as specified and directed by Engineer in charge. Make- Havells LUMILINEPLUSSBS10WLED865SPCSS or equivalent in PHILIPS ,BAJAJ
S & F Sheet metal enclosure DBs Single Pole and Neutral 4 way with 200 Amps rated bus bar 240 volts single pole and neutral complete double door complete all as specified and directed by Engineer in charge.
Supply, fixing and connecting LED flood lights, 100 watt, Energy saving and environmental friendly long life LED flood light made up of pressure die cast aluminium housing with high power LED as lighting source , with IP65 protection and impact resistance complete all as specified and directed.Make:Philips 100 watt,bajaj,C&S Cat Part No JETAIRSFLS100WLED757APWBLTG of Havells of equivelant
Supply and fixing industrial wall mounted plug socket suitable for IP 67 degree of protection of capacity 32 Amps rating 2P+E complete all as specified and directed
Supply and laying Sand cushioning to under ground cable in trenches/existing cable trenches/ducts in layers of 8 cm deep before laying the cable and 15 cm deep after laying and stretching the cable complete all as specified and directed by Engr in charge.
Supply laying the Brick covering with width equal to length of brick as mechanical protection to cable with well burnt sub class ‘B’ bricks laid dry flat complete all as specified and directed by Engr in charge.
Drilling (Horizontally) to existing road ( Maximum 10 mtr wide) suitable for passing GI tubing upto 80mm complete all as specified and directed.
S&F MCCB 100 Amps 4 pole thermal magnetic release 415 volts 50 Hz 25 KA complete including providing aluminium lugs of any size for incoming cable of any type and size complete all as specified and directed Make : Legrand C&S Hevells Schinder
Sachdeva Enterprises
Kirti Chandeliya and Assosicates
STEPUP CONSTRUCTION
C GENDALAL AGRAWAL
chandan construction
Chetna Enterprises
mandeka constructions
Tiki Water proofing Co
MAYOOKH CONSTRUCTION
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .