Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Tender Updates
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹27.8 LAccepted-AOC 212 B 8 PARDEWANPUR LAL BANGLA KANPUR 208007 | KANPUR | KANPUR NAGAR | UTTAR PRADESH | 208007 | L1 | Accepted-AOC Being lowest bidder | |
| 2 | L2₹29.8 L+₹65,920 (2.26%)Rejected-Finance | L2 | Rejected-Finance Other than lowest | |
| 3 | L3₹29.8 L+₹67,545 (2.32%)Rejected-Finance 229 CHANDEL MARKET HARJINDER NAGAR KANPUR 208007 | KANPUR | KANPUR | UTTAR PRADESH | 208007 | L3 | Rejected-Finance Other than lowest |
Tender Value
₹29.9 L
EMD Value
₹59,800
Closing Date
4 Mar 2024, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE (AF) E/M CHAKERI KANPUR
GE(AF)EM CHAKERI
COMPREHENSIVE MAINT OF ELECTRIC SWITCH GEARS AND CONNECTED ITEMS AND FAULT PROTECTION SYSTEM AT AFS KANPUR
2024_MES_640081_1
8696/E8
Open Tender
Civil Works
Item Rate
180 days
Area under GE(AF) EM Chakeri
AS PER TENDER DOCUMENT
9 documents required · 9 mandatory
₹500
GE (AF) E/M CHAKERI
₹59,800
Yes
13 Jun 2024
1 Feb 2024
9 Mar 2024
2 Feb 2024
4 Mar 2024
15 Feb 2024
Amount
M&L for rectification of fault of electrical circuit of 11 KV VCB by checking, repair from CT/PT and programming of multifuntional meters and replacement of defective wiring with and including FRLS multistranded PVC insulated copper conductor 1100 volts grade as per existing size of wire complete all as specified and directed.
M&L for rectification of fault of control circuit of 11 KV VCB by checking, repair of close / trip / spring charging circuit replacement of defective wiring with and including FRLS multistranded PVC insulated copper conductor 1100 volts grade as per existing size of wire complete all as specified and directed.
M&L for rectification of fault of indication circuit of 11 KV VCB by checking, repair of indicating LED lamp circuit, annjuciation system replacement of defective wiring with and including FRLS multistranded PVC insulated copper conductor 1100 volts grade as per existing size of wire complete all as specified and directed.
M&L for rectification of fault of heater circuit of 11 kv VCB by checking, repair of thermostat/heater circuit system replacement of defective wiring with and including FRLS multistranded PVC insulated copper conductor 1100 volts grade as per existing size of wire complete all as specified and directed.
M&L for rectification of fault of AC light circuit of 11 kv VCB by checking, repair of door switch , B-22 polydcarbonate holder and replacement of defective wiring with and including FRLS multistranded PVC insulated copper conductor 1100 volts grade as per existing size of wire complete all as specified and directed.
M&L for rectification of fault of DC 110 volt circuit of 11 kv VCB by checking, repair from battery charger to VCB and internal distribution to other components/system and replacement of defective wiring with FRLS multistranded PVC insulated copper conductor 1100 volts grade as per existing size of wire complete all as specified and directed.
M&L for setting of 3 ph overcurrent+ earth fault relay by injection of current to CTs with suitable equipment for overcurrent & earth fault with high set and low set including checking of all other parameters of relays for proper tripping order after disconection of incomning or out going HT XLPE cable connection from VCB CTs and reconnection of cable ends at existing terminal s after completion of relay setting complete all as specified and directed. Note :- (a) Relay setting shall be made considering corresponding values of upstrem and down strem VCB relays and recorded maximum demand of VCB. Any further adjustment of values as many times required shall be carried out within the quoted rate. (b) Recovery shall be made double the quoted rate if VCB fails to trip in indicated fault and group tripping recorded)
M&L for maintenance/servicing of PT unit 11 KV/110V by disconnecting and taking out from panel mounted position, checking & cleaning of fixed and moving contact points, cleaning/decarbonising of busbar connections, resin cast PTs using hot blower, CTC solution , applying backtol (Red) solution to the epoxi PT body, tighterning of all nuts, bolts, washers, and refxing the same PT to original position, testing complete all as specifie and directed.
M&L for maintenance of 11 KV CT chamber by disconnecting nall 3 ph connections, exdtended busbars and from VCB Bus and taking out from panel mounted position, testing for proper functioning, body leakage, checking & cleaning/decarbonising of all contact points of CT, epoxy body and Busbar, Coplete CT chamber using hot blower, CTC solution , applying backtol (Red) solution to the epoxi PT body, tighterning of all nuts, bolts, washers, and refxing the sameCt to original position,re-connection of all existing cables, extended busbars, testing complete all as specified and directed.
Maintenance, servicing, cleaning of Busbar chamber of each VCB including coneecting Buisbar from CT to Busbar, Spout support insulator, opening of cover using CTC and clean cloth and hot air blower, checking for any loose contact tightning of all nuts & bolts, refixing all covers complete all as specified and directed.
Maintenance, servicing, cleaning of Vacuum circuit breaker unit of 11 KV VCB panel of capacity 400 to 1600 Amps any makes & type , taking out from panel, cleaning of all parts with CTC and clean cloth, removal of carbon deposited inside the moving contacts, greasing of all moving parts of the VCB, checking of complete operating mechanism for proper functioning, reporting for any defective parts, complete all as specified and directed. (Note :- Replacement of defective parts of the VCB shall be mesured and paid separately)
Taking down old UNSV and supply, installation, connection, commissioning and testing of IP-54 factory made (CPRI appvoed) indoor type made of 2mm thick CRCA sheet, floor mounted HT 33 KV control and relay panel board fabricated out minimum 9 fold, chemically or nano ceramic treated and powder coated with after nine tank process, RAL 7032/RAL 7035 approved colour. The panel shall be totally enclosed, symmetrical stable profile frame construction. Enclosure doors shall be fitted with dust tight poly Eurethene from gaskets which can withstand a tempreture of 65 degree centegrate continous with easy operating type fasterners designed to ensore proper compression of gaskets.
Taking down old S & F PVC insulated and PVC sheathed cable galvanised steel strip or wire armoured electric control cables (Heavy Duty) with stranded copper conductor of size 2.5 Sqmm 8 core 1100 volt grade incluiding use of proper thimbles, lugs as in duct, trenches, cable tray or fixing on wall/pole etc. complete all as specified and directed.
All as per item No 13 above but 2.5 Sqmm 4 core 1100 nvolt grade.
Taking down old and supply, installation, connection, commissioning and testing of oil cooled, out door type 33 KV current transformer having ratio of 300-200/5+5+1 A having protection core class 5P 10, burden of 15 VA and metering core class 1.0 and uurden of 15 VA breaking cap of 13.1 KV for 1.0 second comploete all as specified and directed.
Taking down old and supply, installation, connection, commissioning and testing of 33 KV isolator, hand operated triple pole, off circuit, fault making horizontal/vertical mounted, 18 insulator type, centre post rotating type, double stac, 33 KV, 400 Amps complete all as specified and directed.
S&F 12 volt inverter 1000 VA with 150 AH exide maintenance free dry type battery 01 No complete with LED display for status of power back up/battery charging time in hours and minute, MCB for protection from input mains, bypass switch, noiseless operations with the help of low harmonic distortion, plastic battery & invertoer trolly with four wheel having loading capacity 100-150 kg etc. complete all as specified and directed.
S & F in replacement of HT VCB Copper alloy bus bar air insulated, appropriate size and length with 11KV grade Polipro power line protector (sleeve) for designed to insulate bare busbar to prevent accidents due to electrocution/ ionisation. The protector should have excellent UV resistance, abrasion resistance, fire resistance properties, good dieelectric strength & maintenance free complete all as directed by Engr-in-Charge.
Shunt trip closing coil assembly. Make/Type- As per existing sample.
Shunt trip tripping coil assembly. Make/Type- As per existing sample.
Spring charging mechanical assembly with locking arrengement, Make/Type- As per existing sample.
Supply and fix Spring charging motor 24/240 Volt DC/AC for 11KV VCB, Bus Coupler of existing make, type, size & capacity with driving gear suitable for existing VCBs model complete all as specified and directed at site.
Supply and fix Spring charging motor 110/220 Volt DC/AC for 33KV VCB/SF-6 breaker of existing make, type, size & capacity complete all as specified and directed at site.
Supply and fix Spring charging motor 30/240 Volt DC/AC for 11KV & 33KV VCB of existing make, type, size & capacity complete suitable for existing VCBs complete all as specified and directed at site.
Supply and fix Spring charging Motor Cut of switch. Make/Type- As per existing sample.
Supply and fix Ratchet wheel Assembly (small, large & middle gear assy). Make/Type- As per existing sample.
Supply and fix Breaker IN/OUT handle. Make/Type- As per existing sample.
Supply and fix Local remote switch. Make/Type- As per existing sample.
Supply and fix Test/service position indicator. Make/Type- As per existing sample.
Supply and fix Breaker control switch. Make/Type- As per existing sample.
Supply and fix Push button. Make/Type- As per existing sample.
Supply and fix Indicator lamp LED type complete with holder to read RYB with necessary wiring complete.
Supply and fix Spacer Heater. Make/Type- As per existing sample.
Supply and fix Thermostate 30-90 Deg.
Supply and fix Trip /Close shaft assembly with springs & closing strips.
Supply, installation, testing and commissioning in replacement of 11KV Current Transformer with Indoor & Resin cast type single pole (Three core type) CTR-300-200/5+5A, STR - 18.4kA/1Sec, Class - 15VA/CL1.0+15VA/5P10 fixing on existing 11 KV panel including necessary connections, any modification required, addition/alteration required for fixing CT in existing 11 KV panel complete all as directed by Engr-in-Charge.
All as per Srl item No 36 above but CTR-200-100/5+5A, STR - 18.4kA/1Sec.
All as per Srl item No 36 above but CTR-100-80/5+5A, STR - 18.4kA/1Sec.
Taking out IDMT relays from panel. Opening it for repair work, servicing complete with decarburizing the contact points, cleaning with CRC solution and inner body clean with vaccum cleaner etc and repair/replacement of all defective parts if any found during servicing. Reassembling and testing of relays for tripping time setting, over current setting, earth fault setting etc complete all as specified and directed. NOTE :- All parts are deemed to be include in this item rate required for relay in service condition.
S&F in replacement of DC battery charger of capacity 200 AH, 110V/30 Amps FCBD with DCDB suitable for 110V, 200 AH, (VRLA) including maintenance free battery 2 volts 55 Nos and suitable MS stand for staking of batteries and connection to HT panel complete all as specified and directed. Make:- Amara Raja
Supply & fix in replacement of single (Red-Blue) phase busbar spout suitable for 400 amp to 1250 amps VCB including testing complete. Make & size:- as per existing.
Supply & fix in replacement of single (Y) phase busbar spout suitable for 400 amp to 1250 amps VCB including testing complete. Make & size:- as per existing.
Supply and fixing cable jointing kit termination for HT 33KV grade cable for straight through joint complete with jointing material (Heat shrink type) and accessories suitable for XLPE armoured aluminium conductor cable of size185 to 300 Sqmm, 3 core including testing after jointing complete. Make :- Reychem, Denson, 3M
Supply and fixing cable jointing kit termination outdoor type for HT 33KV grade cable for end termination joint complete with jointing material (Heat shrink type) and accessories suitable for XLPE armoured aluminium conductor cable of size 185 to 300 Sqmm, 3 core and testing after jointing.Make :- Reychem, Denson, 3M
M&L for earthing complete with galvanised or steel earth plate electrode of size 600x600x6mm thick burried directly in ground vertically ( to a depth not less than 2.25mtr deep below normal ground level) with top edge of the plate not less than 1.5 mtr below normal ground level, connected to strip 32x 6 mm size drwn throun 40mm GI light grade pipe with nuts, bolts , check nuts , washers, earth plate surrounded by packed layers of charcoal dust and common salt 15cm thick all around, top & bottom watering pipe 20mm bore of GI medium grade with funnel and wiremesh all as shown in electrical plate No. 3 of SSR -2009 Part-I and connecting to earthing test point,main switch board and testing on completion including PCC chamber concrete (1:3:6) type C-2 and RCC cover 75mm thick reinforced with mild steel TMT bar 8mm dia @ 150mm c/c both ways in cement concrete(1:2:4) type B-1 all as shown in electrical plate in No 3 of SSR(Pt-I)2009 and including providing earth identification plate (indicating earth test results, earthing number & date of earthing with black paint over white paint back ground) of 1.6mm thick welded with 25x25x5mm angle iron goruted in ground in PCC 1:3:6 type C2 complete all as specified and dirfected by Engineer-in-charge. Note:- up to 7.5mtr earth strip shall be deemed to be inclusive in quoted unit rate.
Dismantling, taking out all earth connection of strip from any type panel board/transformer to earth test point any size and reploace the worn out earth strip,proper clamp, shadle,nut/bolts and washers connect all joint with new nuts/bolts and washersw to in original posiktion all as specified and directed. Note :- Earth Gi strip measured and paid separetely.
Supply only GI earth strip 32 x 6 mm.
keerti trading corporation
A.B.Enterprises
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .