Loading…
Loading…
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance | Admitted-Finance |
| 2 | Admitted-Finance | Admitted-Finance |
| 3 | Admitted-Finance GOVT CONTRACTOR VPO DHASOLI TEHSIL JAWALI DISTT KANGRA H P | KANGRA | HIMACHAL PRADESH | 175013 | Admitted-Finance |
| 4 | Not Admitted-Fee/PreQual/Technical | Not Admitted-Fee/PreQual/Technical Not Complied with technical specification |
Tender Value
₹76.2 L
Closing Date
20 Oct 2021, 4:00 pmClosed
Estates Officer
Estates Division SKUAST Jammu Chatha
Establishment of cold storage for seed and planting material at Main Campus Chatha civil work
2021_SKUST_141108_2
AU/Estates/21-22/20 dated 22-09-2021
Open Tender
Civil Works
Item Rate
450 days
Main Campus Chatha
Please refer tender documents
4 documents required · 4 mandatory
₹1,500
Yes
Assistant Comptroller Estates SKUAST Jammu
Exempted
27 Oct 2021
24 Sept 2021
21 Oct 2021
29 Sept 2021
20 Oct 2021
29 Sept 2021
Amount
Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan) including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.
All kinds of soil.
Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20 cm in depth: consolidating each deposited layer by ramming and watering lead up to 50 m and lift upto 1.5 m
Providing and laying in position cement concrete of specified grade excluding the cost of centring and shuttering. All work upto plinth level.
1:2:4 (1 Cement : 2 coarse sand(zone-III) : 4 graded stone aggregate 20 mm nominal size).
1:3:6 (1 Cement : 3 coarse sand(zone-III) : 6 graded stone aggregate 20 mm nominal size) (using 30 % boulders including cost and carriage of boulders)
1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size)
Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including necessary excavation leveling and dressing and finishing the top smooth.
Add for plaster drip course/ groove in plastered surface or moulding to R.C.C. projections.
Providing and laying in position specified grade of reinforced cement concrete excluding the cost of centring, shuttering, finishing and reinforcement- All work upto plinth level.
1:1.5:3 (1 cement: 1.5 coarse sand: 3 graded stone aggregate 20 mm nominal size)
Reinforced cement concrete work in walls (any thickness). Including attached pillasters, buttresses, plinth and string courses fillets columns, pillers, piers, abutments, posts and struts etc. upto floor 5 level exclusing cost of centring shuttering, finishing and reinforcement.
1:1.5:3 (I cement : 1.5 coarse sand : 3 graded stone aggregate 20mm nominal size)
Centring and shuttering including strutting, propping etc. and removal of form for
Foundations, footings, bases of columns etc. for mass concrete.
Suspended floors, roofs, landings, balconies and access platform.
Lintels, beams, plinth beams, girders, bresumers and cantilevers.
Columns, pillars, piers, Abutments, posts and struts
Edges of slabs and breaks in floors and walls.
Under 20 cm wide
Reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete
Cold twisted bars/ mild steel and MT steel
Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in :
Cement mortar 1:6 (1 cement : 6 coarse sand)
Supplying and fixing rolling shutters of approved make, made of required size M.S. laths, interlocked together through their entire length and jointed together at the end by end locks, mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation complete, including the cost of providing and fixing necessary 27.5 cm long wire springs manufactured from high tensile steel wire of adequate strength conforming to IS: 4454 -part 1 and M.S. top cover of required thickness for rolling shutters.
80x0.90 mm M.S. laths with 0.90 mm thick top cover.
Steel work in built up tubular ( round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete.
Hot finished welded type tubes.
Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08%and conforming to IS : 15622 , of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand) jointing with grey cement slurry @ 3.3kg/sqm including grouting the joints with white cement and matching pigments etc., complete.
Size of Tile 600x600 mm
Providing and laying Vitrified tiles in different sizes (thickness to be specified by manufacturer) with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make in all colours & shade in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1cement: 3 coarse sand), jointing with grey cement slurry @ 3.3kg/sqm including grouting the joint with white cement & matching pigments etc. complete.
Size of Tile 600x600 mm
10 cm thick (average) mud phaska of damped brick earth on roofs laid to slope consolidated and plastered with 25 mm thick mud mortar mixed with bhusa @ 35 kg per cum of earth and gobri leaping with mix 1:1 (1 clay : 1 cow dung) and covered with flat tile bricks, grouted with cement mortar 1:3 (1 cement : 3 fine sand) mixed with 2% of integral water proofing compound by weight of cement and finished neat :
With common burnt clay F.P.S.(non modular) brick tile of class designation 10.
Providing gola 75x75mm in cement concrete 1:2:4 (1 cement :2 coarse sand : 4 stone aggregate 10 mm and down gauge) including finishing with cement mortar 1:3(1 cement : 3 fine sand) as per standard design
In 75x75mm deep chase
Making khurras 45x45 cm with average minimum thickness of 5 cm cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate of 20 mm nominal size) over P.V.C. sheet 1mx1mx400 micron, finished with 12mm cement plaster 1:3 (1 cement :3 coarse sand) and a coat of neat cement, rounding the edges and making and finishing the outlet complete.
Providing and fixing to the inlet mouth of rain water pipe cast iron grating 15 cm diameter and weighing not less than 440 grams.
12 mm cement plaster of mix : inside plaster
1:6 (1 cement: 6 coarse sand)
18 mm cement plaster in two coats under layer 12 mm thick cement plaster 1:5 (1 cement: 5 coarse sand) finished with a top layer 6mm thick cement plaster 1:6 (1 cement: 6 fine sand). Outside plaster
6 mm cement plaster to ceiling of mix
1: 3 (1 cement: 3 fine sand)
Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade.
New work (two or more coats) over and including water thinnable priming coat with cement primer.
Applying priming coat :
With ready mixed pink or Grey primer of approved brand and manufacture on wood work (hard and soft wood)
Painting with synthetic enamel paint of approved brand and manufacture to give an even shade :
Two or more coats on new work.
Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete.
Providing and fixing Stainless Steel A Isis 304 (18/8) kitchen sink as per IS: 13983 with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required : Make( Hindware/Anupam/Cera/Jindal/Parryware)
510x1040 mm bowl depth 200 mm.
Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete.
Semi rigid pipe
32 mm dia
Providing and fixing G.I. pipes complete with G.I. fittings and clamps, i/c cutting and making good the walls etc. : Internal work – Exposed on wall.
15 mm dia. nominal bore
20 mm dia. nominal bore
Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete :
15 mm nominal bore
20 mm nominal bore
Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass/ stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately) :
For fixed portion
Powder coated aluminium (minimum thickness of powder coating 50 micron)
For shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately).
Powder coated aluminium (minimum thickness of powder coating 50 micron)
Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item):
With float glass panes of 4.0 mm thickness
Providing and fixing double action hydraulic floor spring of approved brand and manufacture conforming to IS : 6315, having brand logo embossed on the body / plate with double spring mechanism and door weight upto 125 kg., for doors, including cost of cutting floors ,embedding in floors as required and making good the same matching to the existing floor finishing and cover plates with brass pivot and single piece M.S. sheet outer box with slide plate etc. complete as per the direction of Engineer-in-charge.
With stainless steel cover plate minimum 1.25 mm thickness.
Providing and fixing 100mm brass locks (best make of approved quality) for aluminium doors including necessary cutting and making good etc. complete.
Providing and laying APP (Atactic Polypropylene Polymer) modified prefabricated five layer, 3mm thick water proofing membrane, black finished reinforced with glass fibre matt consisting of a coat of bitumen primer for bitumen membrane @ 0.40 ltr/sqm. by the same membrane manufactured of density at 25°C, 0.87 - 0.89 kg/ltr and viscosity 70 -160 cps. Over the primer coat the layer of membrane shall be laid using butane torch and sealing all joints etc., and preparing the surface complete.
The vital physical and chemical parameters of the membrane shall be as under : Joint strength in longitudinal and transverse direction at 23°C as 350/300 N/5cm. Tear strength in longitudinal and transverse direction as 60/80N. Softening point of membrane not less than 150°C.Cold flexibility shall be upto -2°C when tested in accordance with ASTM,D - 5147. The laying of membrane shall be got done through the authorised applicator of the manufacture of membrane.
3 mm thick
Providing and laying stone soling including carriage and stacking etc. complete item.
Finishing walls with weather proof exterior paint of required shade :
New work (Two or more coats) over and including water thinnable priming coat with cement primer.
Providing and fixing Panelling (ACP sheet) to the aluminium shutters along with necessary accessories and fittings complete.
Providing and laying good earth including digging, loading, laying etc.
Providing and laying river bed material comprising of sand , stone boulders, earth etc. complete including consolidation, watering, carriages, loading and unloading etc
Diluting and injecting chemical emulsion for pre-constructional Anti-termite treatment complete job including material and labour.
Providing and fixing of the following sanitary items with necessary fittings complete item
CP gratings (100 mm)
CP long body bib cok of approved make (15 mm nominal bore) Make( Hindware/Jaquar/Cera/Plumber/Parryware)
C.I. waste coupling 30 mm of 79 mm length x 77 mm breadth
CP Angle Valve of approved make (15 mm nominal bore)Make( Hindware/Jaquar/Cera/Plumber/Parryware)
Providing and fixing followong PVC pipes along with necessary accessories and fittings (such as tee, elbow, bends, etc.) ( Make:-Supreme/Prince/Astral/Finolex)
PVC pipe (110 mm nominal dia)
Providing and fixing in position PVC water tank of Sintex or Equivalent brand with lockable cover including connection of inlet-outlet over flow and cleaning pipes including cost of GI pipe , G.I fittings complete item of nominal capacity
Providing and fixing of the following accessories including necessary nails and screws complete
Aluminium alloy Handles
Aluminium Tower bolts
Aluminium arle (300 mm)
Door stopper
SUB-DISTRIBUTION BOARDS
Providing and fixing 6 amps to 32 amps rating 240 volts, 'L' series, miniature circuit breaker of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as reqired (category B)
Single Pole - 6 to 32 A
Supply and fixing of following rating, 2P 230 volts, SPN in the existing MCB DB complete with connections, testing and commissiong etc. as required
40 amps SPN
63 amps SPN
EARTHING AND LIGHTNING PROTECTION
Earthing with GI earth plate 600mm x 600 mm x 6mm thick including accessories and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. (with charcoal or coke and salt) complete as required for earthing and lightning protection.
Providing and fixing 25 mm x 5mm GI strip from earth electrode as required
DISTRIBUTION BOARD
Supply, installation, testing at works, installation and commissioning of following distribution boards totally enclosed compartmentalized, cubicle indoor type fabricated with 16 SWG sheet steel, with Aluminium bus bars (both for main and neutral bus bars), complete with following switchgear/ mountings cable terminations, inter-connections as required, for 415 volts, 3 phase, 4 wire 50 HZ AC supply as per specifications and drawings.
Moulded case circuit Breakers shall be thermal magnetic trip type. Fault level for all MCCB and bus bar shall be 35 KA. ICU shall be equal to ICS=100%
All metering current transformers shall be Class 1, 15 VA.
MDB-1 (Indoor Type) Power Panel
Incomer
400 A 50 KA 4P MCCB – 1No.
R,Y,B phase indicating lights with control fuses - 1 set
Bus Bar
400A 415V, 50Hz, 3ph, 4 wire Aluminium Bus bar
Outgoing
40 Amp 4P TPN - 4 No.
63 Amp 4P TPN - 15 No.
MDB-1 (Indoor Type) Light panel
Incomer
250 A 35 KA 4P MCCB – 1No.
R,Y,B phase indicating lights with control fuses - 1 set
Bus Bar
250 A 16 KA 415V, 50Hz, 3ph, 4 wire Aluminium Bus bar
Outgoing
40 Amp 2P SPN - 10 No.
43 Amp 4P TPN - 15 No.
LT CABLES
Supply and laying of PVC Power cable 1.1 KV Grade armoured aluminium XLPE cables including earth work, cost of end termination, thimbles and saddles etc. as required.
3.5C x 120 sq.mm
SUB-DISTRIBUTION BOARDS
Supply and fixing of the following way, single pole and neutral / three pole and neutral, sheet steel, double door, phase segregation type, MCB distribution board, 230V / 415V on surface/recess, complete with tinned copper bus bar, neutral bus bar and link, earth bar, din bar, detachable gland plate, interconnections, including painting, earthing, etc., as required.
8 way TPN
4 way TPN
12 way SPN
Supply and fixing 1x20 watt box type fitting complete with extruded alulminium tube rod including connection testing etc. as reqd. (CAT No. DMLNLT8-16 and LTT8-20)
Supply and fixing 2x20 watt box type fitting complete with extruded alulminium tube rod including connection testing etc. as reqd. (CAT No. IGP-132-LT-8-16)
Supply and fixing of 18 Watt LED Panel surface mounted including connection testing etc as reqd. (CAT No. LCDSPLN-R-18-CDL)
Supply and fixing of 9 Watt LED mirror light 2' long including connection testing etc as reqd. (CAT No. LCTL-09-CDL)
Supply and fixing of 70 Watt LED street light with GI pipe bracket with all accessories including connection testing. (CAT No. LSTP-72-CDL)
Supplying and fixing of batton holder with 7 W LED bulb including connection testing etc as reqd
Wiring for telephone point with 0.61 mm dia copper conductor unarmoured shielded twisted telephone wire in 25mm dia existing PVC conduit, connections etc. complete as required as per specification and drawings.
Supply and fixing telephone socket outlet housed in zinc passivated box with suitable connector strip in recessed wall / partitions as required (piano type)
Supply and fixing of following switch/socket on the modular plate and switch box including connection testing etc as reqd.
TV antenna socket outlet.
R-J-45 moudlar socket.
WIRING
Wiring for light / fan / exhaust fan / call bell point with 1.5 Sq mm FR PVC insulated copper conductor cable in surface / recessed ISI marked PVC conduit(2mm thick) and providing 5 Amp switch (Piano type) and earthing the point with 1.5 sqmm FRLSPVC insultated copper conductor single core cable etc as reqd.
Light point on board with copper wiring in ISI marked PVC conduit wiring for 3 Pin 6 amp plug point with 1.5sqmm PVC insulated multistrand copper conductor cable including P/F of 3 Pin 6 amp socket outlet on switch board in surfaced recessed PVC conduit wiring system and 6 amp switch, earth the 3 pin as required with 01 No. PVIC insulated green colour wire.
Wiring for light plug with 2 x 2.5sq.mm. ISI marked PVC insulated copper conductor single core cable in surface / recessed ISI marked PVC conduit along with 1x 2.5 mm copper wire for loop earthing required
Wiring for power plug with 2 x 4 sq.mm. ISI marked PVC insulated copper conductor single core cable in surface / recessed ISI marked PVC conduit along with 1x2.5 Sq mm copper wire for loop earthing as required
Wiring for power plug with 2 x 1.5sq.mm. ISI marked PVC insulated copper conductor single core cable in surface / recessed ISI marked PVC conduit along with 1x1.5 Sq mm copper wire for loop earthing as required
Wiring for 1x 1.5sq.mm. ISI marked PVC insulated copper conductor single core cable in surface / recessed ISI marked in the existing PVC conduit etc. as required ( Invertor wiring )
Wiring for sub main wiring with following sizes of PVC/ insulated copper conductor wires in the surface/ recessed PVC / MS conduit along with PVC insulated copper conductor earth wire as required complete with connections, testing and commissioning etc. as per specifications and drawings.
2x6 sq mm with 1x6.0sqmm earth wire
4x4 sq mm with 1x4.0sqmm earth wire
2x10sq. mm with 1 x 6.0sq. mm earth wire
4x10 sq mm with 1x6.0sqmm earth wire
Wiring for sub main wiring with4x6 sqmm alongwith 2x6sqmm earth wire sizes of PVC/ insulated copper conductor side core with 1x6 conductor in surface/recessed PVC conduit etc. as reqd.
Wiring for twin control light point with 2x1.5 sq. mm PVC insulated copper conductor cable in surface / recessed ISI marked PVC conduit with 2 way 6 Amp switch modular type
Supplying and fixing metal box of 180 x 100 x60mm deep in recessed with suitable size phoenolic laminated sheet cover in the front including providing and fixing 3 pin 15Amp modular socket outlet and 15Amp modular switch connections, painting etc. as required. (Power plug)
Supply and fixing of 250 mm x 300 mm x 100 mm deep size metal box with suitable size phenolic laminated sheet cover in the front including connection testing etc as reqd.
Supply and fixing of 200 mm x 300 mm x 100 mm deep size metal box with suitable size phenolic laminated sheet cover in the front including connection testing etc as reqd.
Supply and fixing step up electronic fan regulator on the existing switch box including connecting testing etc. as required.
Supply and fixing Call bell / buzzer DC / AC single phase 230 V complete
Supply and fixing of 20 Amp industrial socket for Air-conditioner with 32 Amp SPN including connection, testing, etc. as required
Supply and fixing of 25 mm dia PVC conduit alongwith accessories in surface/recess.
Supply and fixing of 32 mm dia PVC conduit alongwith accessories in surface/recess.
Supply and fixing of CAT-6 wire in the existing PVC conduit including connection testing etc. as reqd.
Narinder Gupta
Sushil Kumar
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .