Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹34.1 CrAccepted-Finance | ₹34.1 Cr | L1 | Accepted-Finance Accept |
| 2 | L2₹34.4 CrAccepted-Finance | ₹34.4 Cr | L2 | Accepted-Finance Accept |
| 3 | Rejected-Technical S NO 280 2 A GALO NO 1 2 3 PLOT NO 358 2 MANIK ELITE BARAMATI DIST PUNE 413102 | PUNE | MAHARASHTRA | 413102 | - | - | Rejected-Technical Disqualified |
| 4 | Rejected-Technical 309 10 SURESHWAR TECHNO IT PARK PREMISES CO OP SOC LTD NEW LINK ROAD BORIVALI WEST MUMBAI 400092 | MUMBAI | MUMBAI SUBURBAN | MAHARASHTRA | 400092 | - | - | Rejected-Technical Disqualified |
| 5 | Rejected-Technical | - | - | Rejected-Technical Disqualified |
Tender Value
₹32.2 Cr
EMD Value
₹16.1 L
Closing Date
20 Mar 2025, 6:00 pmClosed
Executive Engineer
Executive Engineer, P. W. Building Division, Pune at Shivkirti, Ghorpadi, Pune
Construction of Cows Sheds,Silage Bunkers,Bio Gas Unit,Composting and Storage Units, Laboratory, Farmers Hostel, Training Hall, Admin Building, Sales Counter And Labour Residence for Dairy Dept.At College of Agriculture, Pune
2025_PWDRP_1153339_1
E-Tender Notice No. 14 for 2024-25
Open Tender
Civil Works
540 days
Wakdewadi, Khadki
Please refer Tender documents.
3 documents required · 3 mandatory
₹5,900
₹16.1 L
Chief Engineer, P. W. Region, Pune
15 Apr 2025
21 Feb 2025
24 Mar 2025
21 Feb 2025
20 Mar 2025
21 Feb 2025
4 Mar 2025
Amount
CIVIL WORK - Labour charges for removing grass, thorney shrubs, Jungli shrub, Kubabul and alike grass along roadside making the ground clean by showel and phavaras etc. complete
Excavation for foundation in earth, soil of all types, sand, gravel and soft murum, including removing the excavated material up to a distance of 50 metre beyond the building area and stacking and spreading as directed, dewatering, preparing the bed for the foundation and necessary back filling, ramming, watering including shoring and strutting, dewatering etc. complete. (Lift upto 1.5 metre) by Mechanical Means..
Excavation for foundation in hard murum including removing the excavated material upto distance of 50 metres beyond the building area and stacking and spreading as directed, dewatering, preparing the bed for the foundation and necessary back filling, ramming, watering including shoring and strutting, dewatering etc. complete. (Lift from 1.5 metre) by Mechanical Means..
Excavation for foundation in Soft rock and old cement or lime masonry foundations including removing the excavated material upto a distance of 50 metres beyond the building area and stacking as directed, including dewatering, preparing the bed for the foundation and necessary back filling with available earth /murum, ramming, watering including shoring and strutting, dewatering etc. complete (lift upto 1.5 metre) by Mechanical Means.
Excavation for foundation in Hard rock by chiselling, wedging, line drilling, etc. including trimming and levelling the bed, removing the excavated material upto a distance of 50 metres beyond the building area stacking as directed, dewatering and back filling with available earth/ murum watering, ramming etc. complete. (Lift 1.5 To 3 metre) by Mechanical Means.
Providing preconstructional antitermite treatment as per I.S. 6313 (Part-II) by treating the bottom surface and sides of excavation at the rate of 5 litres of emulsion concentrate of 1.0 percent of chlorophyrifos per square meter of surface area covering 10 years guarantee on bond paper.
Providing preconstructional antitermite treatment as per I.S. 6313 (Part-II) by treating the top surface of plinth filling at the rate of 5 litres of emulsion concentrate at 1.0 percent of clorophyrifos per square metre of surface area covering ten years guarantee on bond paper.
Providing dry/ trap/ granite/ quartzite/ gneiss rubble stone soling 15 centimetre to 20 centimetre thick including hand packing and compacting etc. complete
Filling in plinth and floors with approved excavated material in 15 centimetre to 20 centimetre layers including watering and compacting etc. complete. Spec. No. : Bd.A. 11/Page No. 262
Filling in plinth and floors with contractors material/ brought from outside and approved by Engineer incharge in layers of 15 centimetre to 20 centimetre including watering and compaction etc. complete. Spec. No. : Bd.A. 11/Page No. 263
Providing and laying Cast in situ/ Ready Mix cement concrete in Mix- 10 of trap/ granite/ quartzite/ gneiss metal for foundation and bedding including bailing out water, formwork, laying/ pumping, compacting, roughening them if special finish is to be provided, finishing if required and curing complete, with fully automatic micro processor based Programmable Logic Controller with Superwisery Control and Data Acquisition enabled reversible Drum Type mixer/concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand V.S.I. Grade).
Providing and laying in situ/ Ready Mix cement concrete Mix-30 of trap/ granite/quartzite/ gneiss metal for Reinforced Cement Concrete work in foundations like raft, strip foundations, grillage and footings of Reinforced Cement Concrete columns and steel stanchions etc. including bailing out water, formwork, laying/ pumping cover blocks, compaction and curing roughening the surface if special finish is to be provided, (Excluding reinforcement and structural steel) etc. complete, with fully automatic micro processor based Programmable Logic Controller with Superwisery Control and Data Acquisitionenabled Reversible Drum Type mixer/ concrete Batch Mix plant (Pan mixer) etc. complete, with fine aggregate (Crushed sand V.S.I. Grade).
Providing and laying cast in situ/ Ready Mix cement concrete Mix-30 of trap/ granite/ quartzite/ gneiss metal for Reinforced Cement Concrete columns as per detailed designs and drawing or as directed including centering, formwork, cover blocks, laying/ pumping, compaction finishing the formed surfaces with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening if special finish is to be provided and curing etc. complete, (Excluding reinforcement and structural steel) with fully automatic micro processor based Programmable Logic Controller with Superwisery Control and Data Acquisitionenabled Reversible Drum Type mixer/ concrete Batch Mix plant (Pan mixer) etc. complete with fine aggregate (Crushed sand V.S.I. Grade). Ground floor
First floor
Providing and laying Cast in situ/ Ready Mix cement concrete Mix-30 of trap/ granite/quartzite/ gneiss metal for Reinforced Cement Concrete Beams and Lintels as per detailed designs and drawings or as directed including centering, formwork, cover blocks, laying/ pumping, compactionand roughening the surface if special finish is to be provided and curing etc. complete. (Excluding reinforcement and structural steel), with fully automatic micro processor based Programmable Logic Controller with Superwisery Control and Data Acquisitionenabled Reversible Drum Type mixer/ concrete Batch Mix plant (Pan mixer) etc. complete with fine aggregate (Crushed sand V.S.I. Grade). Ground floor
First floor
Providing and laying Cast in situ/ Ready Mix cement concrete Mix-30 of trap/ granite/ quartzite/ gneiss metal for Reinforced Cement Concrete Slabs and Landings as per detailed designs and drawings including centering, formwork, cover blocks, laying/ pumping, compactionfinishing the formed surfaces with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening if special finish is to be provided and curing etc. complete, (Excluding reinforcement and structural steel) with fully automatic micro processor based Programmable Logic Controller with Superwisery Control and Data Acquisitionenabled Reversible Drum Type mixer/ concrete Batch Mix plant (Pan mixer) etc. complete, with fine aggregate (Crushed sand V.S.I. Grade). Ground floor
First floor
Providing and laying Cast in situ/ Ready Mix cement concrete in Mix-30 of trap/ granite/ quartzite/ gneiss metal for Reinforced Cement Concrete Pardi of required thickness including centering, formwork, cover blocks, laying/ pumping, compacting, curing, finishing and rougheningthem if special finish is to be provided and curing complete, (Excluding reinforcement and structural steel) with fully automatic micro processor based Programmable Logic Controller with Superwisery Control and Data Acquisitionenabled Reversible Drum Type mixer/ concrete Batch Mix plant (Pan mixer) etc. complete, with fine aggregate (Crushed sand V.S.I. Grade).
First floor
Providing and laying Cast in situ/ Ready Mix cement concrete Mix-30 of trap/ granite/ quartzite/ gneiss metal for Reinforced Cement Concrete Chajja as per detailed design and drawings including centering, formwork, cover blocks compacting , curing , finishing and roughening the surface if special finish is to be provided and curing complete (Excluding reinforcement and structural steel), with fully automatic micro processor based Programmable Logic Controller with Superwisery Control and Data Acquisitionenabled Reversible Drum Type mixer/ concrete Batch Mix plant (Pan mixer) etc. complete, with fine aggregate (Crushed sand V.S.I. Grade). Ground floor
First floor
Providing and laying Cast in situ/ Ready Mix cement concrete in Mix-30 of trap / quartzite /granite /gneiss metal for Reinforced Cement Concrete Waist Slab, and steps of staircases as per detailed design and drawings or as directed including steel centering, plywood/ steel formwork, steel props, laying/ pumping, compaction, finishing uneven and honeycombed surface with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening the surface if special finish is to be provided and curing etc. complete, with fully automatic micro processor based Programmable Logic Controller with Superwisery Control and Data Acquisitionenabled Reversible Drum Type mixer/ concrete Batch Mix plant (Pan mixer) etc. complete, with fine aggregate (Crushed sand V.S.I. Grade). (Excluding einforcement, including cover block).(Newly laid concrete shall be covered by gunny bag, plastic, tarpaulin ). Ground floor
First floor
Providing and fixing in position Thermo Mechanically Treated (TMT) FE -500 bar reinforcement of various diameters for Reinforced Cement Concrete pile caps, footings, foundations, slabs, beams columns, canopies, staircase, newels, chajjas, lintels pardis, copings, fins, arches etc. as per detailed designs, drawings and schedules, including cutting, bending, hooking the bars, binding with wires or tack welding and supporting as required complete.
First floor
Providing and laying Cast in situ/ Ready Mix cement concrete in Mix-20 of trap/ granite/ quartzite/ gneiss metal for Reinforced Cement Concrete Coping to plinth or parapet and sill of doors and windows moulded as per detailed drawings or chamfered as approved by the Engineer including centering, formwork, cover blocks, laying/ pumping, compacting , curing , finishing and roughening them if special finish is to be provided and curing complete. (Excluding reinforcement and structural steel), with fully automatic micro processor based Programmable Logic Controller with Superwisery Control and Data Acquisitionenabled Reversible Drum Type mixer/ concrete Batch Mix plant (Pan mixer) etc. complete, with fine aggregate (Crushed sand V.S.I. Grade). Ground floor
Providing fly ash brick masonary with conventional /Indian Standardtype fly ash bricks in cement mortar 1:6 in foundation and plinth including bailing out water manually, striking joints, racking out joints, watering and scaffolding complete.
Providing fly ash brick masonary with conventional /Indian Standard type fly ash brick in cement mortar 1:6 for superstructure including striking joints, racking out joints, watering and scaffolding complete.Ground floor
First floor
Providing Autoclaved Areated Concrete block masonary of Ecolite or equivalent make conforming to IS:2185(Part 3)- 1984 in extra fine jointing mortor of fixoblock of UltraTech or equivalent in superstructure including striking joints, racking out joints watering and scaffolding complete. Ground floor
First floor
Providing and fixing chicken mesh of 22 gauge, with about 30 centimetre width at the junction of Reinforce Cement Concrete members and brick work, of approved quality including fixing mesh in position by necessary drilling in concrete/ Burnt Brick Masonry and or tying by binding wire etc. complete. Ground floor
First floor
Providing internal cement plaster 12 milimetre thick in single coat in cement mortar 1:3 without neeru finish to concrete or brick surfaces, in all position including scaffolding and curing etc. complete. Ground floor
First floor
Providing internal cement plaster 20 mm. thick in two coats in cement mortar 1:3 without neeru finish, to concrete, brick surface, in all positions including scaffolding and curing etc. complete. Ground floor
First floor
Providing and applying plaster with plaster of paris in 6 milimetre thickness to previously plastered surface in all position including preparing the surface scaffolding etc. complete. Ground floor
First floor
Providing and applying gypsum plaster (with Gypsum material of Gypsum India/ Mega Sign or equivalent make) with finishing with gypsum material in 10 to 13 millimeter thickness to previously plastered surface/ or on newly brick surface (Excluding rough cast plaster) in all position including preparing and Finishing the surface scaffolding etc. complete. Ground floor
First floor
Providing sand faced plaster externally in cement mortar using approved screened sand, in all positions including base coat of 15 milimetre thick in cement mortar 1:4 using waterproofing compound at 1 kg per cement bag curing the same for not less than 2 days and keeping the surface of the base coat rough to receive the sand faced treatment 6 to 8 milimetre thick in cement mortar 1:4 finishing the surface by taking out grains and curing for fourteen days scaffolding etc. complete. Ground floor
First floor
Providing rough cast cement plaster externally in two coats to concrete, brick or stone masonry surfaces in all positions with base coat of 12 to 15 milimetre thick in cement mortar 1:4 and rough cast treatment 12 milimetre thick in proportion 1:1.5:3 including scaffolding and fourteen days curing complete. Ground floor
Providing and Fixing Processed Stone Cladding on wall surface/ plywood surface. RCC pardi/ Wall and all type of Interior, Exterior Compound wall and Gate etc. of cladding processed stone with material of Processed clay, Wooden chips, Silica sand, Cement, GFRC admixtures, Colour pigments, Fiber up to thick of 230 mm/ 25 mm including scaffolding, fixing of screw, etc. (As directed by Engineer in Charge) Ground floor
Providing and applying Royale Luxury Emulsion of Asian/ Berger/ Nerolac/ Dulux Paints or equivalent make on internal wall surface as detailed below Scrapping for surface with emery paper and wipe clean for area. Applying Asian/ Berger/ Nerolac/ Dulux Paints or equivalent wall primer with brush by adding mineral turpentine oil by 8 to 10 % or water by 15 to 20% allowing to dry for 6 to 8 hoursAfter applying Asian/ Berger/ Nerolac/ Dulux Paints or equivalent acrylic wall putty with appropriate prpportion of water of allow to dry for period of 4 to 6 hours of activity. Scrapping with emery paper and wipe clean Applying paints Royale Luxury emulsion 1st coat with brush water content water 40 to 45% or 65 to 70% by role Applying paints Royale luxury emulsion 2nd coat with brush with water content 40 to 45 % or 65 to 70 % by roller (With prior approval of S.E.). Ground floor
First floor
Providing and applying pearl/ luster finish paint of approved colour and shade to the existing plastered surface including scaffolding preparing the surface applying acrylic wall putti etc. complete.
First floor
Providing and applying two coats Apex Ultima Puranature Anti-Pollution Or equivalent approved brand, paint should decomposes organic substances and inorganic gases(NOx, VOC’s, CO, SOx, formaldehydes, etc.) in presence of natural or artificial light. It contains Graphene and nanoparticles of ium oxide. and Absorbs CO2 (4.8 kg/15 l). plaster crack should be filled by Acrylic base Crack seal/Textured Crack filler, Paint has to applied on one coat of Apex Ultima Puranature Anti-Pollution Primer or Equivalent. Warranty Should be given by the Manufaturer The work should be done by the Manufacturer Recommended applicator and he should be able to furnish stage wise onsite technical reports from the concerned company technologist. Ground floor
First floor
Providing and fixing of Terracotta desiner jali of Nuvocotto or Equivalent make or size having 200x200x50Milimetre as per manufacturer finished with approved colour and pattern The blocks shall be fixed by suitable System by using mortar or special ready mix mortar or adhesive per manufacturer guidelines and specifications with suitab lable thickness of Joining material, size and spacing to withstand the structura peslen criteria specified, supported or ocked by beams or columns as per design height criteria of the cladding as per manufacturer technical specification, Claddine joints should be with as per design and drawings including cutting, jointing. fixing, scaffolding, cleaning, lead, Its, handling etc complete as shown in design, drawings and specifications as directed by engineer & In charge Sample needs to get approved from project architect before execution of work as directed by engineer-in charge
First floor
Providing and fixing 20 to 25 milimetre thick rough shahabad box type waterproofing for basement or underground floor on a base of Cement concrete 1:3:6, including sub base of 2.50 centimetre thick Cement mortar 1:3 with conceal, setcrete (RMW), Algaeproof or other alike water proofing liquids, raking of joints upto 35 milimetre depth,filling the joints with 6 milimetre size crushed metal, hand grouting with cement slurry, curing and cleaning, with 7 years guarantee on court fee stamp of Rs. 100/- with ponding test etc complete. (excluding Cement concrete 1:3:6 base concrete). Ground floor
Providing and fixing 20 to 25 milimetre thick rough shahabad box type waterproofing treatment to vertical outside faces of Reinforced Cement concrete walls of basement or underground floor including filling the gap of 25 milimetre between rough shahabad and Reinforced Cement concrete walls with cement grout mixed with water proofing liquid Algaeproof or other alike with one tile lift method, brushing the joints horizontally with cement slurry mixed with water proofing liquid for width 30 to 35 milimetre and sloping coping over topmost tile with cement mortar 1:3, butting the bottom most with Cement concrete 1:2:4 mixed with water proofing liquid, curing, with 7 years guarantee on court fee stamp of Rs. 100/- with ponding test etc complete. (excluding Cement concrtete 1:3:6 base concrete).
Providing water proof bedding for flooring of bath and water closet, 25 milimetre thick in cement mortar 1:3 including using approved water proofing compound in specified proportion as per manufacturers specifications for per bag of cement including leveling, curing and covering 10 years guarantee on court fee stamp paper of Rs.500/- including ponding test etc. complete.
First floor
Providing waterproofing in Water Closet and bath including brick bat coba in all position including providing and laying 12 milimetre bedding in cement mortor 1:3 on vergin concrete slab with waterproofing compound at the rate of 1kg/ per bag of cement laying brick bat coba of required thickness in cm 1:5 with waterproofing compound 1 kilogram per bag of cement grouting and finishing the top layer with 20 milimetre thick brick bedding in cement mortor 1:3 with waterproofing compound 1 kilogram per bag of cement and testing the treated portion for 48 hours by pond test and covering ten years' guarantee on requisite stamp paper including curing etc. complete. Ground floor
First floor
Shingles on Roof: Providing and fixing shingles on Roof of size 17x40 inch to 13.1/4* to 39.1/8° of asphalt. The material are resistance against fire and atmospheric aggressions and are developed using high quality material and cutting edge technology.
Providing and laying in position flooring of telephone black/ Amba White/ Cat bary brown/ Ruby red/ Ocean Brown granite stone of approved shade and size 18 milimetre to 20 milimetre thick on bed 1:6 cement mortar including cement floats striking joints, pointing in Cement Mortar 1:3 curing and cleaning etc. complete.Ground floor
First floor
Providing and fixing machine cut machine polished 18 milimetre to 20 milimetre thick telephone black/ Amba White/ Cat bary brown/ Ruby Red/ Ocean Brown granite stone for treads and risers of steps and staircases of approved colour and shade with rounded moulding and three grooved line for the treads on bed of 1:4 Cement mortar including float filling joints with neat cement slurry curing polishing and cleaning etc. complete. Ground floor
First floor
Providing and laying telephone black/ Amba White/ Cadbury Brown/ Ruby red/ Ocean Brown granite stone of 18 to 20 mm thick for door frame/ dado/ window boxing etc. on Cement Mortar 1:6 including filling joints with polymer base filler nosing the sharp edges wherever necessary, curing, etc. complete. Ground floor
First floor
Providing leather finished polishing to Granite Stone slab by continuous grinding in 4 coats of different bits to receive rough and matt finish including buffing process before laying and fixing of stone as per drawing and design, including cleaning, washing and finishing etc. complete. Ground floor
First floor
Providing and laying vitrified matt fininsh tiles for flooring having size 590 milimetre to 605 milimetre of 8 to 10 milimetre thickness and confirming Indian Standard 15622-2006 (Group Bla) of approved make, shade and pattern for flooring in required position laid on a bed of 1:4 cement morar including neat cement float, filling joints, curing and cleaning etc. complete. Ground floor
First floor
Providing and laying vitrified matt finish tiles for Skirting having size 590 milimetre to 605 milimetre x to 605 milimetre of 8 to 10 mm thickness and confirming Indian Standard 15622-2006 (Group Bla) of approved make, shade and pattern for flooring in required position laid on a bed of 1:4 cement mortar including neat cement float, filling joints, curing and cleaning etc. complete. Ground floor
First floor
Providing and fixing 15 milimetre thick eco-friendly densified edge calcium silicate fall ceiling (like aeroltie) of approved texture spintone/cosmos/hexa or equivalent of size 595 milimetre x 595 milimetre in true horizontal level, suspended on interlocking metal grid of hot dipped galvanized steel sections (galvanising at the rate 12 gram per square metre including both sides) consisting of main “T” runner suitably spaced at joints to get required length and size 24 x 38 milimetre made from 0.33 milimetre thick (minimum ) sheet, spaced 1200 milimetre center to center and cross “T” of size 24x28 milimetre made of 0.33 milimetre thick (minimum ) sheet to be interlocked at the middle of the 1200 x 600 milimetre panel to form the grid of size 600 x 600 milimetre resting on periphery walls/partitions on a perimeter wall angle precoated steel of size 24 x24x 3000 made of 0.4 milimetre thick (minimum) sheet with the help of all plugs at 450 milimetre and laying 15 milimetre thick densified edges calcium silicate ceiling tiles of approved texture (spintone/ cosmos/ hexa) in the grid, including light fittings, fixtures, smoke detectors, wherever required. Main “T” runners suspended from ceiling with using Galvanised Iron slotted cleats of size 25x35x1.6 milimetre fixed to ceiling using 12.5 milimetre diametre and 50 milimetre long dash fasteners, 4 milimetre Galvanised Iron adjustable rods with galvanized steel levels clips of size 85x30x0.8 milimetre, spaced at 1200 milimetre center to center along main “T” bottom exposed with 24 milimetre of all T-sections shall be prepainted with polyester baked paint, for all heights, as per specifications, drawings complete. (currently this item should be used only for VIP cabins).
First floor
Providing and Fixing of Armstrong or equivalent Mineral Fibre Acoustical Suspended Ceiling System with ultima (Bevelled Tegular) Edge Tiles With Armstrong or equivalent 15 milimetre Exposed GRID. The tiles should have Humidity Resistance (RH) of 99 percent, NRC 0.7, Light Reflectance ≥85 percent, Thermal Conductivity k = 0.052 - 0.057 w/m K, Colour White, Fire Performance UK Class 0 / Class 1 (BS 476 pt - 6 and 7) in module size of 600 x 600 x 20 milimetre, suitable for Green Building application, with Recycled content of 32 percent.The tile shall be laid on precoated Galvanised Iron channel on XL2 Clip having a web height of 32 milimetre with 15 milimetre wide T- section flanges colour white having rotary stitching on all T sections i.e. the Main Runner, 1200 milimetre and 600 milimetre Cross Tees with a web height of 32 milimetre and a load carrying capacity of 7.7 Kilogramme per square metre and minimum pull out strength of 100 Kilogram. The T Sections have a Galvanizing of 90 grams per square metre and need to be installed with Suspension system of Armstrong or equivalent make. . The Tile and Grid system used together should carry a 10 year warranty. products approved as per GRIHA and BS :476
First floor
Providing and fixing in position Gypsum board false ceiling with 12.5 milimetre thick Gypsum boards, screwed/ fixed to the under structure of suspended galvanised iron Grid constructed and suspended from the main ceiling consisting of ceiling sections of size 25 x 50 milimetre maximum center to center distance of 600 milimetre perimeter channel and intermediate channels at maximum center to center distance 1200 milimetre galvanized grid should be fixed to reinforced cement concrete slab. The gypsum board should be fixed to galvanized iron grid with necessary screws. The boards should be taped and filled from underside to give smooth, seamless ceiling. The rate should include necessary additional ceiling sections and intermediate channels. Additional intermediate channels should be fixed to strap hangers for additional support to prevent strapping at every 1200 milimetre item to be completed in all respect including necessary sleeves for ducts finishing of joints cut outs, painting including labour, material, lifts etc. all complete. Ground floor
First floor
FALSE CEILING SYSTEM GI METAL BIOGUARD CLIP IN PLAIN TILE WITH CARRIER SYSTEM 600 X 600MM Providing & Fixing horizontal level suspended ceiling comprising of GI Bioguard Clip-in Plain Tile 600x600mm (Nominal Size) tiles of 120 gsm galvanized steel as per IS 277 (2003) suitable for architectural finishes in 0.5mm thickness as per in IS:513 (1994) in Global white color with concealed suspension system having a bevelled edge of 3x3mm and height of 33mm on one side and 18mm on the other side. Tiles shall be flattened by precision leveller to minimize sag to less than 1/400mm. The tiles shall have double round pip of ɸ 2mm and ɸ 6mm for secure engagement and levelling respectively, along with swing down feature and special tabs to allow removal of tile to enable plenum access. The coated surface of the tile shall exhibit anti-microbial properties (eradication and inhibition of growth) and shall achieve up to 99.99% reduction in bacterial activity as per ISO22196:2011. The tile shall be electrostatically polyester powder coated using RoHS compliant powder having coating thickness ranging from 60-80 microns. The powder coating shall pass Salt Spray Test for 750 Hours as per ASTM B117, QUV –A Test for 1000hours as per ASTM G- 154 – (Cycle – 1) and Humidity test for 1000hours as per DIN 50017. The powder coating shall have an adhesion of GT0 as per EN ISO 2409. The shade variation across batches shall be delta E<1 using Excite/BYK Gardner instrument and gloss level of 25±5% at 60˚ as per ASTM D523. The tile shall have scratch, mar & abrasive resistance properties. The tile shall have a Light Reflectance of ≥ 63% in accordance to ASTM 1477-98 and Fire Performance of class 0/1 as per BS 476 Part 6 & 7 in module size of 600x600mm. SUSPENSION & INSTALLATION: Shall comprise of 3000mm long ‗C‘ channels of 38H x 12W mm and 1mm thick spaced at 1200mm centre to centre securely fixed to the structural soffit using threaded rod (Approved make/Third Party Supply) connecting to C-channel hanger of 109x18.5x16.5mm at 1200mm C/C and anchor fastener (Approved make/Third Party Supply). The last hanger at the end of each C-channel shall not be greater than 600mm from the adjacent wall. Use a C-channel connector of 99.5x35x 9mm for splicing together two pieces of C-channels. 4000mm Clip-in bar of 16W x 40H mm and 0.6mm thick made of galvanized steel of 140gsm as IS 277 (2003) and shall be spaced at 600mm centre to centre in a direction perpendicular to the C-channels and secured at every intersection with C-channel using a Clip-in bar hanger of 54x18x20mm. Use Clip-in bar connecter to splice two pieces of Clip-in bar. Tiles shall be clipped in between two Clip-in bars from below. Optionally - Security clip to be installed to ensure the panels are positively engaged with Clip-in bar channel. Installation shall be carried out as per Manufacturer recommended procedure. Perimeter to be finished using wall angles of size 3000x19x32mm in white color secured to walls using screws at 450mm centre to centre. Cut tiles to be secured to the wall angles using a spring clamp. The Tile & Grid system used together shall carry a 10 year warranty against manufacturing defect and manufacturer shall provide a warranty certificate. The Tile & Grid shall have the manufacturers name embossed/printed on it. The supply shall be backed by a Manufacturing Test Certificate.
First floor
Providing and fixing frame with / without ventilator of size as specified with teak wood for doors and windows including chamferring, rounding, rebating, iron holdfast size 300 milimetre x 40 milimetre x 5 milimetre with oil painting complete. Ground floor
First floor
Providing and fixing in position powder coated aluminium louvered windows ventilator of various sizes with powder coating as per detailed drawing and specifications including aluminium frames 80 x 38 milimetre x 1.22 milimetre box type, 5 milimetre thick sheet glass louvers, of approved quality complete. Ground floor
First Floor
Providing and fixing in position (as per 1868:1982) Aluminium sliding window of three tracks with rectangular pipe 95 x 38.10 x 0.90 milimetre at weight 0.637 kilogram per running metre with window frame bottom track section 92 x 31.75 x 1.30 milimetre at weight 1.070 kilogram per running metre. Top and side track section 92 x 31.75 x 1.30 milimetre at weight 0.933 kilogram per running metre. The shutter should be of bearing bottom 40 x 18 x 1.25 milimetre at weight 0.417 kilogram per running metre Inter locking section 40 x 18 x 1.10 milimetre at weight 0.469 kilogram per running metre and handle and top section 40 x 18 x 1.25 milimetre at weight o.417 kilogram per running metre. As per detailed drawings and as directed by Engineer-in-charge with all necessary Aluminium sections fixtures and fastenings such as roller bearing in nylon casting and self locking catch fitted in vertical section of shutter including 5 milimetre thick plain glass and aluminium mosquito net shutter with stainless steel jail with all required screws and nuts etc. complete with powder coating without box. Ground floor
First floor
Providing and fixing mild steel grill work for windows, ventilators 20 kilogram per square metre as per drawing including fixtures, necessary welding and painting with one coats of anticorrosive paint and two coats of oil painting complete. Ground floor
First floor
Providing and fixing in position, Single shuttered aluminium extruded powder coated openable door of overall size 0.90 metre x 2.40 metre with aluminium door frame of powder coated section 101.60 x 44.75 milimetre, 3.18 milimetre thick and shutter comprising of powder coated section having bottom and lock rail of size 150 milimetre x 44.5 milimetre x 3.00 milimetre thick top rails 47.62 x 44.45 milimetre x 3.00 milimetre thick, vertical style 47.62 x 44.45 milimetre, 3.00 milimetre thick and for shutter plain glass panes 5 milimetre thick for top panels and 12 milimetre thick both side laminated phenol bonded particle board panels for bottom panels etc., Indian Standard Institute mark, with bijagiri having heavy duty concealed lock, necessary beading, glazing clips, Poly Venyl Chloride gaskets, 250 milimetre length tower bolts, 150 milimetre diameter pad handle, etc. as per detailed design and drawing or as directed by engineer in charge including all materials, labours and equipment etc. complete. Ground floor
Providing and fixing country cut teak wood single leaf pannelled door shutter without fanlight 35 milimetre thick as per drawing consisting of teak wood top rail size 100 milimetre x 35 milimetre and bottom rail and lock rail 200 milimetre x 35 milimetre insert pannel 12 milimetre thick commercial ply faced teak wood particle board with phenol formaldehyde synthetic resin (Generally conforming to Indian Standard 3097) excluding frame, including stainless steel fixtures and fastening and fastening and teak wood beading to junctions of pannelled inserts and as instructed by Engineer in charge including three coats of oil painting etc. complete.
First floor
Providing and fixing the country cut teak wood double or single leaf second class fully pannelled door shutter with 35 milimetre thick style and rail with 25 milimetre thick pannels with openable fan light as per detailed drawings. Excluding the door frame 60 milimetre x 100 milimetre, including stainless steel fixtures and fastening and finishing the wood work with oil panting 3 coats Ground floor.
First floor
Providing and Fixing 30 milimetre thick both side Prelaminated Solid Panel Poly Venyl Chloride Door Shutter consisting of frame made out of Mild Steel tubes of 19 guage thickness and, size 19 x 19 milimetre for styles and 15 x15 milimetre for the top and bottom rails, Mild Steel frame shall have a coat of metel primer of approved make and manufacture. Mild Steel frame shall be covered with heat mouled Poly Venyl Chloride ' C ' channel made from 5 milimetre (+/- 0.25) thick prelaminated sheet of density 600 kilogram per cubic metre, of size 30 milimetre thickness 70 milimetre width out of which 50 milimetre shall be flat and 20 milimetre shall be tapered in 45 degree angle on either side forming stiles and 5 milimetre thick, 95 milimetre wide Poly Venyl Chloride sheet out of which 75 milimetre shall be falt and 20 milimetre shall be tapered in 45 degree angle on the inner side to form top and bottom rail and 115 milimetre wide Poly Venyl Chloride sheet out of which 75 milimetre shall be falt and 20 milimetre shall be tapered on both sides to form lock rail.Top,bottom and lock rail shall be provided either side of the panel. An additional 5 milimetre (+/- 0.25) thick Poly Venyl Chloride strip of 20 milimetre width is to be stuck on the bottom side of the ' c ' channel prelaminated paneling of 5 milimetre (+/- 0.25) thick Poly Venyl Chloride sheet to be fitted inside the mild steel frame welded/ sealed to the styles and rails with 5 milimetre (+/- 0.25) x 30 milimetre Poly Venyl Chloride sheet beading on either side and joined together with solvent cement adhesive etc ,10 milimetre thickness (5 milimetre (+/- 0.25) x 2 nos ) 20 milimetre wide cross Poly Venyl Chloride sheet as gap insert for the rail and bottom rail. Door to be fixed to frames with 3 nos mild steel powder coated but hinges of size 100 milimetre x 25 milimetre x 2 milimetre using 32 milimetre long steel screws drilled suitable to pass through both the walls of the Mild Steel tube. Other hardwares should be fixed with 19 x 6 milimetre size steel screws including fixture fasting complete as per direction of engineer -in -charge.
First floor
Supply and installation of CEILING HUNG cubicles of width and depth as per specifications/ site drawings. Cubicle height to be 2400 mm. Std Sizes (W x D x H): 900 mm x 1550 mm x 2400 mm, (Height is including 100 mm gap from bottom) Door Width- 600 mm ITEM DESCRIPTION Made from solid grade Merino make compact high pressure laminate as per IS:2046 and EN 438 manufactured under high specific pressure > 5 MPa and temperature >120° C, All doors will be of single colour and made of 18 mm thick Merino HPL compact panel. The doors will have chamfered edges. Each door will be supported by 3 stainless steel made hinges affixed to the pilasters. All intermediate partitions or dividers will be made of 12 mm thick Merino HPL compact laminate panels. Size of panels to be as per drawing. HARDWARE & ACCESSORIES are H shaped (Top) head frame structure made of extruded Aluminum grade 6063 T5-50 micron epoxy powder coated for surface protection. Size to be 125x70x5T. Corner joinery section, Size to be 40x16.5x1.8T. U-Channel Wall joinery section, Size to be 22x16x1.6T. Door stopper section, Size to be 21x12.5x1.6T. Spring loaded Butt Hinges made from Stainless steel grade 304. Surface finish to be matt type. Covers to be lacor coated.Coat hook with rubber stopper made from Stainless steel grade 304. Surface finish to be matt type. etc complete.
First floor
Providing and Fixing mat finish stainless steel (of 302 grade) railing with top pipe of 50 milimetre diameter and vertical pipe of 38 milimetre diameter at 0.60 metre center to center or as required and horizontal pipes of 25 milimetre diameter in three rows, all pipes of 2 milimetre thick including buffing,fabricating fixtures and fastening including pipe base of appropriate diameter and ball base of 75 milimetre diameter above newel post of 75 milimetre diameter etc. complete (Prior approval of sample and brand by Ex.Engineer is necessary before use). Ground floor
First floor
Providing and fixing 40 milimetre diameter and 1.5 milimetre thick Stainless steel hand railing in S.S. 304 Grade including fabricating, fixtures, errecting, necessary welding, grinding, finishing, buffing to stainless steel pipe
First floor
Providing and constructing granite kitchen platform with fixing of stainless steel sink 600 milimetre x 450 milimetre size as per detailed drawing including vertical both side polished kadappah stone 25 to 30 milimetre thick supports with kadappah top 35 to 40 milimetre thick and polished granite 16 to 20 milimetre top with side strips of granite at front and both sides of platform raised with two vertical granite supports 15 centimetre height and top granite of 75 x 40 centimetre including cutting, opening for sink of required size in kadappah as well as granite etc. complete. Ground floor
Providing and fixing sink cock with regular swinging spout (Wall Mounted Model) with wall flange with approved make incluidng other necessary fitting, etc. complete as directed by Engineer in charge.
Providing and fixing white european type wall-hung pan, of size 350 milimetre x 355 milimetre x 570 milimetre concealed flush tank with floor-mounting frame installing kit and drain pipe connection set for wall hung WC, with approved make square control plates including soil pipe, vent pipe upto the outside face of wall, 100 milimetre dia C.I. plug bend inlet pipe all fittings,cutting & making good walls, floors etc. complete. Ground floor
First floor
Providing and fixing Oval Type Under Counter Wash Hand Basin of 420 x 590 x 195 milimetre size with pillar cock, C.P.Angular stop cock, long thread of approved make continental including SS bottle trap of necessary pipe connection up to the outside face of the wall, having Telephonic Black / Colour Granite of 180 milimetre thick fixed on Black Kadappa Framework, etc. Complete as directed by Engineer in charge. Ground floor
First floor
Providing and fixing Table top white wash basin of size 120x635x405 milimetre rubber plugs and brass chain, with pillar cock, C.P.Angular stop cock long thread, continental including S.S. bottle trap of approved make having necessary pipe connection up to theoutside face of the wall.etc complete as directed by Engineer in charge. Ground floor
First floor
Providing and fixing C.P. 2 Way BIB cock with wall flange of approved make including necessary sockets/ union nut etc. complete as directed by Engineer in charge. Ground floor
First floor
Providing & fixing 15 milimetre diameter Poly Vinyl Chloride Aqua kraft type of approved make super jet spray with flange 2 in 1 faucet 1.50 metre long including all accessories etc. complete. Ground floor
First floor
Providing and fixing Shower Head, with shower arm of approved make mixer of including all necessary pipe fittings and connections etc. complete as directed by Engineer in charge. Ground floor
First floor
Providing and fixing 15 cm rigid Poly Venyl Chloride Nahani trap including Poly Venyl Chloride grating, bend, connecting piece of Unplasticised Poly Venyl Chloride pipe up to the outside face of wall, making the good damaged surface and testing complete. ( Prior approval of sample and brand by Ex. Engr. is necessary before use). Ground floor
First floor
Providing and fixing 15 centimetre x 10 centimetre salt glazed stoneware gully trap in cement concrete 1:4:8 out side the building including cast iron grating in the sink, connecting glazed stonewre pipe brick masonry chamber with cast iron lid and cast iron grating for the gully trap. Ground floor
Providing and fixing on walls / ceiling / floor 15 milimetre diameter Chlorinated Poly Venyl Chloride pipe with necessary fittings, remaking good the demolished portion. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed complete.
First floor
Providing and fixing on walls / ceiling / floor 20 milimetre diameter Chlorinated Poly Venyl Chloride pipe with necessary fittings, remaking good the demolished portion. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed complete. Ground floor
First floor
Providing and fixing on walls / ceiling / floor 25 milimetre diameter Chlorinated Poly Venyl Chloride pipe with necessary fittings, remaking good the demolished portion. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed complete. Ground floor
First floor
Providing and fixing on walls / ceiling / floor 32 milimetre diameter Chlorinated Poly Venyl Chloride pipe with necessary fittings, remaking good the demolished portion. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed complete. Ground floor
First floor
Providing and fixing on walls / ceiling / floor 40 milimetre diameter Chlorinated Poly Venyl Chloride pipe with necessary fittings, remaking good the demolished portion. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed complete. Ground floor
First floor
Providing and fixing on walls / ceiling / floor 50 milimetre diameter Chlorinated Poly Venyl Chloride pipe with necessary fittings, remaking good the demolished portion complete. Ground floor
First floor
Providing and fixing screw down for 25 milimetre diameter wheeled stop tap of brass including necessary sockets/union nut complete. Ground floor
First floor
Providing and fixing screw down for 32 milimetre diameter wheeled stop tap of brass including necessary sockets/union nut complete. Ground floor
First floor
Providing and fixing screw down for 50 milimetre diameter wheeled stop tap of brass including necessary sockets / union nut complete. Ground floor
First floor
Providing and fixing on walls/ ceiling/ floors, 50 milimetre diameter heavy grade having embossed as Indian Standard Institute Mark galvanised iron pipes of 6.33 kilogrames per metre with necessary fitting, remaking good the demolished portion and applying primer of anti-corrosive oil paint in 2 coats complete. Ground floor
First floor
Providing and fixing 75 milimetre diameter stabiliser pipe /Poly Venyl Chloride soil vent /waste pipe and with necessary fixtuers and fiting such as bends, tees, single junctions slotted vent, clamps complete. Ground floor
First floor
Providing and fixing 100 milimetre diameter stabiliser pipe /Poly Venyl Chloride soil vent /waste pipe and with necessary fixtuers and fiting such as bends, tees, single junctions slotted vent, clamps complete. Ground floor
First floor
Providing and fixing Poly Venyl Chloride Rain water pipes of 160 milimetre outer diameter and having wall thickness of 2.2 to 2.7 milimetre confirming to Indian Standard 13592-1992 including proper rainwater receiving recess with Poly Venyl Chloride plug, bend, necessary fittings, such as, offsets, shoes, inluding fixing the pipe on wall using approved wooden cleats projecting 25 milimetre to 40milimetre from face of wall a fixing with clips of approved quality and number, filing the joint using rubber gasket with solvent cement and properly resting the shoe of pipes on Cement Concrete or masonry blocks, including necessary scaffolding and maintenance for 3 years for any leakages or dislocations of pipes. All the Poly Venyl Chloride fittings and additional 2 piece socket clips shall be got approved from engineer in charge complete. (The contractor shall give 3 years guarantee bond for payment). Ground floor
First floor
Providing and laying concrete pipe of Indian Standard Non Pressure class of 100 milimetre diameter in proper line, level and slope including necessary collars, excavation, laying, fixing with collars in cement mortar 1:1 and refilling the trench complete.
Providing and laying concrete pipe of Indian Standard Non Pressure class of 150 milimetre diameter in proper line, level and slope including necessary collars, excavation, laying, fixing with collars in cement mortar 1:1 and refilling the trench complete.
Providing and laying concrete pipe of Indian Standard Non Pressure class of 225 milimetre diameter in proper line, level and slope including necessary collars, excavation, laying, fixing with collars in cement mortar 1:1 and refilling the trench complete.
Providing and laying concrete pipe of Indian Standard Non Pressure class of 300 milimetre diameter in proper line, level and slope including necessary collars, excavation, laying, fixing with collars in cement mortar 1:1 and refilling the trench complete.
Providing and constructing Brick Masonry Inspection Chamber 60 centimetre x 45 centimetre x 90 centimetre including 1:4:8 cement concrete foundation 1:2:4 cement concrete channels half round Glazed Stone Ware pipes, Brick Masonry, plastering from inside and with frame fixed in cement concrete with Reinforced Cement Concrete cover medium duty 140 kilogram with frame etc. complete.
Providing and constructing Brick Masonry Inspection Chamber 90 centimetre x 45 centimetre x 90 centimetre including 1:4:8 cement concrete foundation 1:2:4 cement concrete channels half round Glazed Stone Ware pipes, Brick Masonry, plastering from inside and with frame fixed in cement concrete with Reinforced Cement Concrete cover medium duty 140 kilogram with frame etc. complete.
Providing and fixing High Density Polymer container Syntex or alike one piece moulded water tank made out of high density polythyler and built corrugated inclusive of delivery up to destination hoisting and fixing of accessories such as inlet, outlet overflow pipe inclusive of all tanks capacity between 1000 to 20000 liters.
Providing and fixing 90 centimetre x 60 centimetre Granite plate engraving 10 centimetre height letter, figures including painting the letters/ figures with approved colour and shade complete.
Providing and fabricating structural steel work in rolled sections like joists, channels, angles, tees etc. as per detailed design and drawings or as directed including cutting, fabricating, hoisting, erecting, fixing in position making riveted /bolted / welded connections without connecting plates, braces etc. and including one coat of anticorrosive paint and over it two coats of oil painting of approved quality and shade etc. complete.
Providing and fixing colour coated Zincalume ( R ) AZ150 ( min 150 gms/sq.mt. total on each side ) profiled sheets for roofing. The feed material is manufactured out of nominal 0.45 mm Base Metal Thickness ( BMT ) (0.5 mm TCT ), Hi-strength steel with min.550 MPa yield strength, metallic hot dip coated with Aluminium-Zinc alloy (55% aluminium 43.4% zinc 1.6% silicon) with COLORBOND ( R ) steel quality super durable polyester paint coat ( with inorganic pigment). The paint shall have a total coating thickness of nominal 35 um, comprising of nominal 25 um exterior coat on top surface and nominal 10 um reverse coat on back surface. Profile sheet shall have nom. 950-1050 mm effective cover width and nominal 25-30 mm deep ribs with subtle square fluting in the five pan at nominal 180-250 mm center-to-center. The end rib shall be designed for anti-capillary groove. and return leg. The feed material should have coil manufacturers product details marked a regular interval. Including fasteners with min. fastened with min. 25 um Zinc-Tin alloy coated, Hex head, self-drilling screw etc. complete. (weight of profile 4.52 kg/sqm)
Providing and fixing heavy duty inter locking concrete Coloured paving blocks of 80 milimetre thickness of having a strength of 300 kilogram per square centimetre of approved quality and shape on a bed of crushed sand of 25 to 30 milimetre thick including skirting joints and cleaning etc. complete
Providing and laying in situ cement concrete M30 with tremix treatment for 200 millimeter thickness for flooring with groove cutting of 4 millimeter wide and 20 millimeter deep with necessary refilling with bitumen complete.
Providing and casting in situ or precast tapering Reinforced Cement Concrete Mix-20 Mountable type Kerb without gutter (as per IRC:86-1983) embedded 125 milimetre below ground level over Mix-10 Plain Cement Concrete finished neatly with Cement Mortar 1:2, setting the same in Cement Mortar 1:2, including the required excavation in any strata and removing the excavated stuff any where in city and redoing the surface as specified and directed by Engineering In-charge. Using Concrete Batching and Mixing Plant.
Providing and fixing rolling shutter fabricated from steel laths of minimum thickness 0.9 milimetre with lock plate of 3.15 milimetre thickness reinforced with 35 x 35 x 5 milimetre angle section fitted with sliding bolts and handles for both sides, deep Mild Steel channel section of depth and thickness not less than 65 milimetre and 3.15 milimetre respectively with hold fast arrangments, Mild Steel Bracket plate 300 x 300 x 3.15 milimetre minimum size and shape with square bar suspension shaft of minimum 32 milimetre diameter, hood cover of Mild Steel sheet not less than 0.9 milimetre thickness and of any size at top and safety devices including mechanical gear operation arrangementconsisting of worm gear whwwls and worms of high grade cast iron or mild steel and one coat of red lead primer complete. (I. S. 6248 - 1979) with mechanical gear.
Providing and laying in situ/ Ready Mix cement concrete Mix-25 of trap/ granite/quartzite/ gneiss metal for Reinforced Cement Concrete work in foundations like raft, strip foundations, grillage and footings of Reinforced Cement Concrete columns and steel stanchions etc. including bailing out water, formwork, laying/ pumping cover blocks, compaction and curing roughening the surface if special finish is to be provided, (Excluding reinforcement and structural steel) etc. complete, with fully automatic micro processor based Programmable Logic Controller with Superwisery Control and Data Acquisitionenabled Reversible Drum Type mixer/ concrete Batch Mix plant (Pan mixer) etc. complete, with fine aggregate (Crushed sand V.S.I. Grade).
Providing and laying Cast in situ/ Ready Mix cement concrete in Mix-25 of trap/ granite/ quartzite/ gneiss metal for Reinforced Cement Concrete Pardi of required thickness including centering, formwork, cover blocks, laying/ pumping, compacting, curing, finishing and rougheningthem if special finish is to be provided and curing complete, (Excluding reinforcement and structural steel) with fully automatic micro processor based Programmable Logic Controller with Superwisery Control and Data Acquisitionenabled Reversible Drum Type mixer/ concrete Batch Mix plant (Pan mixer) etc. complete, with fine aggregate (Crushed sand V.S.I. Grade).
Providing and laying cast in situ/ Ready Mix cement concrete Mix-25 of trap/ granite/ quartzite/ gneiss metal for Reinforced Cement Concrete columns as per detailed designs and drawing or as directed including centering, formwork, cover blocks, laying/ pumping, compaction finishing the formed surfaces with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening if special finish is to be provided and curing etc. complete, (Excluding reinforcement and structural steel) with fully automatic micro processor based Programmable Logic Controller with Superwisery Control and Data Acquisitionenabled Reversible Drum Type mixer/ concrete Batch Mix plant (Pan mixer) etc. complete with fine aggregate (Crushed sand V.S.I. Grade).
Providing and laying Cast in situ/ Ready Mix cement concrete Mix-25 of trap/ granite/quartzite/ gneiss metal for Reinforced Cement Concrete Beams and Lintels as per detailed designs and drawings or as directed including centering, formwork, cover blocks, laying/ pumping, compactionand roughening the surface if special finish is to be provided and curing etc. complete. (Excluding reinforcement and structural steel), with fully automatic micro processor based Programmable Logic Controller with Superwisery Control and Data Acquisitionenabled Reversible Drum Type mixer/ concrete Batch Mix plant (Pan mixer) etc. complete with fine aggregate (Crushed sand V.S.I. Grade).
Providing and applying epoxy paint primer with middle coat and top coat to superstructure including scaffolding etc complete.
Providing and fixing mild steel grill door 24 kilogram per squaremetre of various size as per detailed drawings without hot dip coating, iron fixtures and fastenings and 3 coats of oil painting etc
Providing and fixing Orissa Pan of size 580x445x260 milimetre with approved make flush valve including trap, C.I. soil and vent pipe upto outside face of wall including 100 milimetre dia. C.I. plug, bend and necessary pipe connection, etc complete. As directed by Engineer in charge.
Providing and fixing coloured Glazed Earthenware full stall type Urinal with Poly Venyl Chloride flushing cistern of 5 litre capacity with fittings, inlet pipes and stop tap, brackets for fixing the cistern, 32 milimetre diameter Poly Venyl Chloride flush pipe with fittings and flushing arrangement including lead soil pipe, lead trap and soil pipe connection up to the outside face of the wall.
Providing and laying Cast in situ/ Ready Mix cement concrete Mix-25 of trap/ granite/ quartzite/ gneiss metal for Reinforced Cement Concrete Slabs and Landings as per detailed designs and drawings including centering, formwork, cover blocks, laying/ pumping, compactionfinishing the formed surfaces with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening if special finish is to be provided and curing etc. complete, (Excluding reinforcement and structural steel) with fully automatic micro processor based Programmable Logic Controller with Superwisery Control and Data Acquisitionenabled Reversible Drum Type mixer/ concrete Batch Mix plant (Pan mixer) etc. complete, with fine aggregate (Crushed sand V.S.I. Grade).
Providing and applying a base coat comprising of 1 kilogram Polydee-MC and 1 kilogram fresh cement after wetting the surface followed by drying the surface for 2 days, apply primer coat of TP-40 and after drying, applying Polydee-11 two component (mixing ratio 2 A: 1 B) Antibactorial food grade coating inside drinking watertank in two coats with time interval of minimum 8 hours covering 7 years guarantee on Court Fee Stamp Paper of Rs.100/- etc complete
Providing and fixing reinforced cement concrete Heavy duty (160 kilogram) cover of size 60 centimeter x 45 centimeter with frame over inspection chamber complete.
Providing and laying in situ/ Ready Mix cement concrete Mix-20 of trap/ granite/quartzite/ gneiss metal for Reinforced Cement Concrete work in foundations like raft, strip foundations, grillage and footings of Reinforced Cement Concrete columns and steel stanchions etc. including bailing out water, formwork, laying/ pumping cover blocks, compaction and curing roughening the surface if special finish is to be provided, (Excluding reinforcement and structural steel) etc. complete, with fully automatic micro processor based Programmable Logic Controller with Superwisery Control and Data Acquisitionenabled Reversible Drum Type mixer/ concrete Batch Mix plant (Pan mixer) etc. complete, with fine aggregate (Crushed sand V.S.I. Grade).
Providing and laying cast in situ/ Ready Mix cement concrete Mix-20 of trap/ granite/ quartzite/ gneiss metal for Reinforced Cement Concrete columns as per detailed designs and drawing or as directed including centering, formwork, cover blocks, laying/ pumping, compaction finishing the formed surfaces with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening if special finish is to be provided and curing etc. complete, (Excluding reinforcement and structural steel) with fully automatic micro processor based Programmable Logic Controller with Superwisery Control and Data Acquisitionenabled Reversible Drum Type mixer/ concrete Batch Mix plant (Pan mixer) etc. complete with fine aggregate (Crushed sand V.S.I. Grade).
Providing and laying Cast in situ/ Ready Mix cement concrete Mix-20 of trap/ granite/quartzite/ gneiss metal for Reinforced Cement Concrete Beams and Lintels as per detailed designs and drawings or as directed including centering, formwork, cover blocks, laying/ pumping, compactionand roughening the surface if special finish is to be provided and curing etc. complete. (Excluding reinforcement and structural steel), with fully automatic micro processor based Programmable Logic Controller with Superwisery Control and Data Acquisitionenabled Reversible Drum Type mixer/ concrete Batch Mix plant (Pan mixer) etc. complete with fine aggregate (Crushed sand V.S.I. Grade).
Providing, fabricating and erecting at site of work the tubular steel structure (shed) as per standard design and specifications having various spans in between trusses and in multiples of standard length of bays as specified as per standard specifications, inclusive of cost of steel tubular trusses, tubular columns purlins, tie runners, foundation bolts, base plates, nuts and bolts, welding wherever required etc. as per detailed drawing inclusive of one coat of anticorrosive paint and two coats of oil painting of approved quality and shade etc. complete.
Providing and fixing 50 milimetre diameter medium class Galvanised Iron pipe gate with wicket gate of approved drawing with all fixtures and fittings in two leaves with strong hold fast embedded in Cement Concrete block at top and bottom with locking arrangement including cutting, bending, making holes and with one coat of primer complete.
Excavation for roadway in earth soil of all sorts, sand, gravel or soft murum including dressing section to the required grade camber and side slopes and conveying the excavated materials with all lifts upto a lead of 50 metre and spreading for embankment or stacking as directed.
Providing earth work in embankment with approved materials obtained from other sources upto lead of 50 metre including all lifts, laying in layers of 20 centimetre to 30 centimetre thickness breaking clods, dressing to the required lines, curves, grades and section, watering and compaction with vibratory roller with V-Sat attachment to achieve not less than 97% of standard proctor density etc. complete (Material obtained from Other sources).
Supplying hard murum at the road site including conveying and stacking complete.
Compacting the hard murum side widths including laying in layers on each side with power roller including artificial watering complete.
Construction of granular sub-base by Plant Mix Method by providing close graded Material, mixing in a mechanical mix plant at Optimum Moisture Content, carriage of mixed Material to work site,spreading in uniform layers with Motor Grader/ Paver on prepared surface and compacting with vibratory power roller to achieve the desired density complete as per clause 401.For Grading I Material.
Providing, laying, spreading and compacting stone aggregates of specific sizes to water bound macadam specification including spreading in uniform thickness, hand packing to proper grade and camber, applying and brooming requisite type of screening/ binding Materials to fill up the interstices of coarse aggregate, watering and compacting with vibratory roller to the required density. By Mechanical Means Grading-I, using Screening Type-B (11.2 milimetre Aggregate).
Providing, laying, spreading and compacting stone aggregates of specific sizes to water bound macadam specification including spreading in uniform thickness, hand packing to proper grade and camber, applying and brooming requisite type of screening/ binding Materials to fill up the interstices of coarse aggregate, watering and compacting with vibratory roller to the required density. By Mechanical Means Grading-II (Using Screening Type-B (11.2 milimetre Aggregate).
Proving and laying Dense Bituminous Macadam using crushed aggregates of grading 1, premixed with bituminous binder VG-30 bitumen at the rate 4.50 percent by weight of total mix and filler, transported to site with Vehicle Tracking System, laid over a previously prepared surface, finished to the required grade, level, alignment and rolling to achieve the desired density for 76-100 milimetrem compacted thickness, using Batch mix type hot mix plant with SCADA, Sensor Paver, Vibratory Roller with Stone Dust filler.
Providing and laying Bituminious Concrete using crushed aggregate of grading 1, premixed with bituminious binder of dose 5.40 percent by weight of total mix and filler, transported at site with Vehicle Tracking System, laid over a previously prepared surface, finished to the required grade, level, alignment and rolling to achieve the desired density for 50 milimetre compacted thickness with Drum Mix type hot mix plant with Superwisery Control and Data Acquisition, Sensor Paver and Vibratory Roller excluding prime/Tack coat etc. complete with Bitumen VG-30 grade with stone dust filler.
Providing and applying Cold plastic paint two component rolled on surfacing material solvent free,high build two pack seamless,tough,skid resistant,material with has property of attaining 2.00 milimetre thickness in single coat application white(or as required colour) based on glass and colour retaining acralic cross linking resin system for coloured road surfacing including surface cleaning and cost of all material etc. complete. (All inclusive on bitumen or concrete surface) work shall carried out as per IRC 35-2015 clause 2.2).
Providing and casting in situ or precast tapering Reinforced Cement Concrete Mix-20 Barrier type Kerb with gutter (as per IRC:86-1983) embedded 125 milimetre below ground level over Mix-10 Plain Cement Concrete finished neatly with Cement Mortar 1:2, setting the same in Cement Mortar 1:2, including the required excavation in any strata and removing the excavated stuff any where in city and redoing the surface as specified and directed by Engineering In-charge. Using Concrete Batching and Mixing Plant.
PLANTING SPECIMEN TREES - (2 to 3 Mir Helght) :- Digging pil with size 1.0 m × 1.0 m x 1.0 m Removing & conveying unwanted stuff to a required distance as directed. filling the pil with approved excavaled material up to a hight of 0.35 m. and remaining height of 0.65 m, with fresh garden soil & manure in in 3:1 proportion. Mixing soil and manure thoroughly well, leveling, as directed, watering previous night. Planting two or three year old, minimum 2.0 to 3.0 mr. height, healthy tree sapling of Wad /Banyan Maintaining fill well established by watering, weedings, Stirring of soil, staking, replacing of casualties etc. complete.
Preparing Lawn (30 cms.Depth) Excavating the ground to a required depth of 30 cms. Removing & conveying unwanted stuff to a required distance as directed. Filling fresh garden soil/silt & manure in excavated area in 3:1 proportion to a height of 30cms. Mixing garden soil and manure
ELECTRICAL WORK - Supplying and erecting HMS PVC conduit FRLS grade 25 mm dia. with necessary accessories in wall/floor with chiselling appropriately as per specification No WG-MA/CC
Supplying and laying HMS PVC conduit FRLS grade 25 mm dia with necessary accessories in RCC work/false ceiling/false flooring as per specification No. WG-MA/CC
Supplying and erecting HMS PVC conduit FRLS grade 32 mm dia. with necessary accessories in wall/floor with chiselling appropriately as per specification No WG-MA/CC
Supplying and laying HMS PVC conduit FRLS grade 32mm dia. with necessary accessories in RCC work/false ceiling/false flooring as per specification No. WG-MA/CC
Supplying and erecting mains with 2x1.5 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places as per specification No WG-MA/BW
Supplying and erecting green colour earthing with 1x 1.5 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places as per specification No WG-MA/BW
Supplying and erecting mains with 2x2.5 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places. as per specification No WG-MA/BW
Supplying and erecting green colour earthing with 1x 2.5 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places. as per specification No WG-MA/BW
Supplying and erecting mains with 2x4 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places. as per specification No WG-MA/BW
Supplying and erecting green colour earthing with 1x 4 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places. as per specification No WG-MA/BW
Supplying and erecting mains with 2x6 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places. as per specification No WG-MA/BW
Supplying and erecting green colour earthing with 1x 6 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places. as per specification No WG-MA/BW
Supplying and erecting modular type switch 6A / 10A duly erected on provided plate and box with wiring connections complete.
Supplying and erecting modular type switch 16A duly erected on provided plate and box with wiring connections complete.
Supplying and erecting modular type 3 pin 6A multi socket with safety shutter duly erected on provided plate and box with wiring connections complete.
Supplying and erecting modular type 3 pin 6 / 16A multi socket with safety shutter duly erected on provided plate and box with wiring connections complete.
Supplying and erecting modular type T.V. socket single outlet duly erected on provided plate and box with wiring connections complete.
Supplying and erecting modular type telephone socket one gang with safety shutter duly erected on provided plate and box with wiring connections complete.
Supplying and erecting unbreakable concealed type modular switch box with double mounting plate for 2 module duly erected flush to wall with required chiselling and finishing with cement mortar / POP as per required to match the background.
Supplying and erecting unbreakable concealed type modular switch box with double mounting plate for 3 module duly erected flush to wall with required chiselling and finishing with cement mortar / POP as per required to match the background.
Supplying and erecting unbreakable concealed type modular switch box with double mounting plate for 6 module duly erected flush to wall with required chiselling and finishing with cement mortar / POP as per required to match the background.
Point wiring for light/bell concealed type in min 20 mm FRLS grade HMS PVC conduit with 1.5 sq.mm. (2+1E) FRLSH grade copper wires modular type switch earthing and required accessories as per specification No WG-PW/CW
Point wiring for light/bell concealed type in min 20 mm FRLS grade HMS PVC conduit with 1.5 sq.mm. (2+1E) FRLSH grade copper wires modular type switch earthing and required accessories as per specification No WG - PW/CW
Point wiring for ceiling fan concealed type in min 20 mm FRLS grade HMS PVC conduit with 1.5 sq.mm. (2+1E) FRLSH grade copper wires modular type switch earthing and required accessories as per specification No WG-PW/CW
Point wiring for independent plug concealed type in min 20 mm FRLS grade HMS PVC conduit with 1.5 sq.mm (2+1E) FRLSH grade copper wires modular type switch earthing and required accessories as per specification No WG-PW/SW
Point wiring for light/bell hybrid type (Surface type under false ceiling and concealed type for drops & switch boards on walls) in min 20 mm PVC conduit / casing n capping with 1.5 sq.mm. (2+1E) FRLSH grade copper wires modular type switch earthing and required accessories as per specification No WG-PW/HW
Point wiring for ceiling fan (Surface type under false ceiling and concealed type for drops & switch boards on walls) in min 20 mm PVC conduit / casing n capping with 1.5 sq.mm. (2+1E) FRLSH grade copper wires modular type switch earthing and required accessories as per specification No WG-PW/HW
Secondary point wiring for additional light/ bell point concealed type in min 20 mm FRLS grade PVC conduit with 1.5 sq.mm. (2+1E) FRLSH grade copper wires with required accessories as per specification No WG-PW/CW
Wiring for plug on board with Switch socket surface/concealed type copper wiring and earthing and with modular accessories as per specification No WG-PW/CW
Supplying and erecting 2 pair telephone copper cable 0.5 mm dia. with high density polyethylene insulation polyester taped Nylon Rip Cord & grey colour sheathed with FR PVC conforming to ITD specification S/WS 113C laid in provided PVC casing capping/conduit as per specification No. WG-TW
Supplying and erecting co-axial copper cable low voltage grade tri-shielded RG-6 as per specification No. WG-TW
Supplying and installing cat-6 cable suitable for networking as per specification no. WG-COC/NC
Supplying and fixing tool-less IO (Ethernet) flush/surface type in provided modular box as per specification no. WG-NAS/IO
Supplying and erecting LED square / circular Max. 25 W down lighter/ Panel Light having pressure die-cast aluminium housing polystyrene diffuser having system lumens output of Min. 2750 Lumens min. efficacy of 110 lumen/W CRI>80 CCT upto 6500K Beam Angle of 120 deg. max. ripple of 5% THD<10% p.f. >0.95 operating range of 120-270V surge protection of 2.5 kV Life class of 50 000 Hrs. at L70B50 including driver having mounting arrangement with board for surface type or spring loaded mounting clips complete with 3 years warranty.
Supplying and erecting LED Panel Light(600mm X 600mm) Max. 35 W having CRCA powder coated housing polystyrene diffuser having system lumens output of Min 4200 Lumens min. efficacy of 120 lumen/W CRI>80 CCT upto 6500K Beam Angle of 120 deg. max. ripple of 5% THD<10% p.f. >0.95 operating range of 120-270V surge protection of 2.5 kV Life class of 50 000 Hrs. at L70B50 including driver having mounting arrangement with board for surface type or spring loaded mounting clips complete with 3 years warranty.
Supplying and erecting LED Strip light 5m Length Max. 95 W IP20 class having minimum lumens output of 1600 Lumens/m min. efficacy of 90 lumen/W CRI>80 CCT upto 5000K Beam Angle of 110 deg. THD<10% p.f. >0.95 operating range of 230-270V Life class of 30 000 Hrs. at L70B50 including driver with 1 year warranty.
Supplying LED concealed type foot / step light with aluminium body for indoor/outdoor application suitable for 4W-6W LED including driver and erecting by making necessary arrangement / recess in wall to make it flush with surface with 1 year warranty.
Supplying and erecting CRCA powder coated corridor/passage light LED fitting (4 feet) Max. 17W with high transitivity diffuser with system lumens output of Min. 2000 lumens min. efficacy of 120 lumen/W CRI>80 CCT upto 6500K Beam Angle of 120 deg. Ripple<5% THD<10% p.f. >0.95 operating range of 120-270V surge protection of 4 kV Life class of 50 000 Hrs. at L70B50 including driver with end caps on provided PVC Block / wooden board with 3 years warranty.
Supplying and erecting CRCA powder coated corridor / passage light LED fitting (4 feet) Max. 33W with high transitivity diffuser with system lumens output of Min. 4000 lumens min. efficacy of 120 lumen/W CRI>80 CCT upto 6500K Beam Angle of 120 deg. Ripple<5% THD<10% p.f. >0.95 operating range of 120-270V surge protection of 4 kV Life class of 50 000 Hrs. at L70B50 including driver with end caps on provided PVC Block / wooden board with 3 years warranty.
Supplying and erecting anodized aluminium corridor / passage / mirror light LED fitting (2 feet) Max. 12W with high transitivity diffuser with min. system lumens output of 1200 lumens min. efficacy of 100 lumen/W CRI>80 CCT upto 6000K Beam Angle of 110 deg. Ripple<5% THD<10% p.f. >0.95 operating range of 200-270V surge protection of 2 kV Life class of 50 000 Hrs. at L70B50 including driver with end caps on provided PVC Block / wooden board with 3 years warranty.
Supplying and erecting integrated LED Highbay Fitting 70W IP65 & IK08 class having die cast aluminium housing with polycarbonate diffuser with integrated optics having system lumens output of Min.10000 Lumens min. efficacy of 145 lumen/W CRI>70 CCT upto 6500K THD<10% p.f. >0.90 operating range of 140-240V inbuilt surge protection of 4 kV Life class of 50 000 Hrs. at L50B50 including driver complete with 3 Year warranty as per specification No FG-ODF/FLS2.
Supplying and erecting fresh air cum exhaust fan of light duty 250 V A.C. 50 cycles 300mm. 1400 RPM rust proof body & blades wire mesh duly erected complete.
Supplying and erecting Energy Saving BLDC Ceiling fan 230 V A.C. 50 cycles 1200 mm max. energy consumption of 28W having service ratio (CMM/W) of Min. 8 PF>0.9 THD<10% with IR remote control/compatible speed regulator Temperature Rise of Max. 40 deg. C having external mounted control PCB completely erected in position as per specification no. FG-FN/CF
Supplying and erecting fan hook box of 10 mm M.S. round bar bounded to the R.C.C. bars upto 50 mm length each side and pierced through a 16 S.W.G. thick aluminium/M.S. Bowl 100 mm dia. or equivalent square size and having depth upto 75 mm complete erected with duly painted by one coat of red oxide paint and two coats of paint erected in position and without any leakage of slurry of cement concrete on either side of the box and positioned to the bottom level of the slab.
Supplying and erecting ding dong / electronic musical type call bell with heavy duty coil suitable to operate on 230V A.C. supply erected on polished double wooden block/sunmica block of suitable size.
Supplying, erecting and marking SPMCB 6A to 32A C-series with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB
Supplying, erecting and marking SPMCB 6A to 32A B-series with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB
Supplying and erecting triple pole and neutral distribution board (TPNDB) SPMCB of 8 ways / phase (24 poles) with door 1.2mm thickness surface/ flush mounted IP 43 Protection on iron/GI frame (horizontal busbar type) as per specification no. SW-SWR/MCBDB
Supplying and erecting triple pole and neutral distribution board (TPNDB) SPMCB of 12 ways /phase (36 poles) with door 1.2mm thickness surface/flush mounted IP 43 Protection on iron/GI frame (horizontal busbar type) as per specification no. SW-SWR/MCBDB
Supplying and erecting single pole and neutral distribution board (SPNDB) with 2 ways for incoming and 10 ways (10 poles) for outgoing SP MCBs with door 1.2mm thickness surface / flush mounted IP 43 Protection on iron / GI frame as per specification no. SW-SWR/MCBDB
Supplying and erecting CRCA sheet metal enclosures of 1.2mm thickness with 30 A 3 pin plug & earth socket and 30A 3 pin plug top with 30A triple pole MCB having rated short - circuit breaking capacity (Icn) 10kA complete erected on angle iron / GI frame.
Supplying, fixing, and commissioning 2 pole RCBO 32/40A with overcurrent rated short-circuit breaking capacity (10 kA) and earth leakage protection with 30/100/300 mA sensitivity and short circuit and earth leakage trip indication as per specification no SW-RCCB/RCBO
Supplying, fixing, and commissioning 4 pole RCBO 32/40A with overcurrent rated short-circuit breaking capacity (10 kA) and earth leakage protection with 30/100/300 mA sensitivity and short circuit and earth leakage trip indication as per specification no SW-RCCB/RCBO
Supplying, fixing, and commissioning 4 pole RCBO 63A with overcurrent rated short-circuit breaking capacity (10 kA) and earth leakage protection with 30/100/300 mA sensitivity and short circuit and earth leakage trip indication as per specification no SW-RCCB/RCBO
SITC of Admin Panel having details as below The panel shall be comprising of following & IEC 61439 Panel with should be fully ompartmentallised Floor mounted with M.S. Channel dully painted fabricated of 14/16swg CRCA sheets completely derusted chemically treated and powder coated with approved shade ON - Off Indicating LED lamp locking arrangements withdual source intelligent flush mounted panel meter three phase four wire (IPM) 415V CT/ PT site programmable class I flush mounted (96 x 96mm) meter with voltage current frequency power factor ON hrs kWh EB and DG set metering and LT current transformer with bar primary 50/5 to 1600/5 ratio with 15 VA burden with IOT Based metering stsyem and gateway included as per SLD having following items - (MSEDCL APPROVED)(RA WITH PWD DSR) Main Incomer 1 Nos - 200A 4P MCCB 50kA LSIG Microprocessor based with all indication and On-off Trip Contacts and breaker history 1 No 200A 4P Automatic Changeover 50kA Outgoing 4 Nos. 100A 3P MCCB LSI with provision of Shunt/ UV/ Trip. 8 Nos 3P MCB 40-63A with provision of Shunt/ UV/ Trip.
SITC of Training Hall & Kitchen having details as below The panel shall be comprising of following & IEC 61439 Panel with should be fully ompartmentallised Floor mounted with M.S. Channel dully painted fabricated of 14/16swg CRCA sheets completely derusted chemically treated and powder coated with approved shade ON - Off Indicating LED lamp locking arrangements withdual source intelligent flush mounted panel meter three phase four wire (IPM) 415V CT/ PT site programmable class I flush mounted (96 x 96mm) meter with voltage current frequency power factor ON hrs kWh EB and DG set metering and LT current transformer with bar primary 50/5 to 1600/5 ratio with 15 VA burden with IOT Based metering stsyem and gateway included as per SLD having following items - (MSEDCL APPROVED)(RA WITH PWD DSR) Main Incomer 1 Nos - 200A 4P MCCB 50kA LSIG Microprocessor based with all indication and On-off Trip Contacts and breaker history 1 No 200A 4P Automatic Changeover 50kA Outgoing 11 Nos 3P MCB 40-63A with provision of Shunt/ UV/ Trip.
SITC of Dorms having details as below The panel shall be comprising of following & IEC 61439 Panel with should be fully ompartmentallised Floor mounted with M.S. Channel dully painted fabricated of 14/16swg CRCA sheets completely derusted chemically treated and powder coated with approved shade ON - Off Indicating LED lamp locking arrangements withdual source intelligent flush mounted panel meter three phase four wire (IPM) 415V CT/ PT site programmable class I flush mounted (96 x 96mm) meter with voltage current frequency power factor ON hrs kWh EB and DG set metering and LT current transformer with bar primary 50/5 to 1600/5 ratio with 15 VA burden with IOT Based metering stsyem and gateway included as per SLD having following items - (MSEDCL APPROVED)(RA WITH PWD DSR) Main Incomer 1 Nos - 100A 4P MCCB 36kA LSIG Microprocessor based with all indication and On-off Trip Contacts and breaker history 1 No 100A 4P Automatic Changeover 36kA Outgoing 11 Nos 3P MCB 40-63A with provision of Shunt/ UV/ Trip.
SITC of Milk Process having details as below The panel shall be comprising of following & IEC 61439 Panel with should be fully ompartmentallised Floor mounted with M.S. Channel dully painted fabricated of 14/16swg CRCA sheets completely derusted chemically treated and powder coated with approved shade ON - Off Indicating LED lamp locking arrangements withdual source intelligent flush mounted panel meter three phase four wire (IPM) 415V CT/ PT site programmable class I flush mounted (96 x 96mm) meter with voltage current frequency power factor ON hrs kWh EB and DG set metering and LT current transformer with bar primary 50/5 to 1600/5 ratio with 15 VA burden with IOT Based metering stsyem and gateway included as per SLD having following items - (MSEDCL APPROVED)(RA WITH PWD DSR) Main Incomer 1 Nos - 200A 4P MCCB 50kA LSIG Microprocessor based with all indication and On-off Trip Contacts and breaker history 1 No 200A 4P Automatic Changeover 50kA Outgoing 4 Nos. 100A 3P MCCB LSI with provision of Shunt/ UV/ Trip. 11 Nos 3P MCB 40-63A with provision of Shunt/ UV/ Trip.
SITC of Sales Counter having details as below The panel shall be comprising of following & IEC 61439 Panel with should be fully ompartmentallised Floor mounted with M.S. Channel dully painted fabricated of 14/16swg CRCA sheets completely derusted chemically treated and powder coated with approved shade ON - Off Indicating LED lamp locking arrangements withdual source intelligent flush mounted panel meter three phase four wire (IPM) 415V CT/ PT site programmable class I flush mounted (96 x 96mm) meter with voltage current frequency power factor ON hrs kWh EB and DG set metering and LT current transformer with bar primary 50/5 to 1600/5 ratio with 15 VA burden with IOT Based metering stsyem and gateway included as per SLD having following items - (MSEDCL APPROVED)(RA WITH PWD DSR) Main Incomer 1 Nos - 100A 4P MCCB 36kA LSIG Microprocessor based with all indication and On-off Trip Contacts and breaker history Outgoing 11 Nos 3P MCB 40-63A with provision of Shunt/ UV/ Trip.
Supplying and erecting PVC insulated PVC round sheathed 2.5 sq.mm (50 no. x 0.25 mm dia.) 3 core flexible multi stranded copper Industrial cable for voltage grade up to 1.1 kV
Supplying and erecting PVC insulated PVC round sheathed 4 sq.mm (56 no. x 0.30 mm dia.) 3 core flexible multi stranded copper Industrial cable for voltage grade up to 1.1 kV
Supplying, erecting & terminating FR XLPE insulated galvanised steel formed wire armoured (strip) cable 1100 V 3 core 6 sq. mm. copper conductor complete erected with glands & lugs on wall/ trusses/ pole or laid in provided trench/ pipe as per specification no. CB-LT/CU
Supplying, erecting & terminating FR XLPE insulated galvanised steel formed wire armoured (strip) cable 1100 V 3½ core 25 sq. mm. aluminium conductor complete erected with glands & lugs on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL
Supplying, erecting & terminating FR XLPE insulated galvanised steel formed wire armoured (strip) cable 1100 V 3½ core 95 sq. mm. aluminium conductor complete erected with glands & lugs on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL
Supplying, erecting & terminating FR XLPE insulated galvanised steel formed wire armoured (strip) cable 1100 V 4 core 16 sq. mm. aluminium conductor complete erected with glands & lugs on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL
Providing and erecting hot dipped galvanised ladder type cable tray manufactured from 16 SWG (1.6 mm thick) GI sheet of 150 mm width & 100 mm height comprising all required standard accessories.
Providing and erecting hot dipped galvanised ladder type cable tray manufactured from 16 SWG (1.6 mm thick) GI sheet of 200 mm width & 100 mm height comprising all required standard accessories.
Providing and erecting hot dipped galvanised ladder type cable tray manufactured from 16 SWG (1.6 mm thick) GI sheet of 300 mm width & 100 mm height comprising all required standard accessories.
Providing earthing with galvanized iron earth plate size 60 x 60 x 0.6 cm complete with all materials testing & recording the results as per specification no. EA-EP
Supplying and erecting GI strip of high purity required size used for earthing on wall and/or any other purpose with necessary GI clamps fixed on wall painted with bituminous paint with joints required. As per specification no EA-EP.
Supplying, installing, testing and commissioning of 10kVA capacity online pure sine wave with backup time of half hrs. PWM & IGBT based UPS with 0.9 to unity output pf 3 phase input & 3 phase output complete with all protections as per specification no. AP-UPS
Supplying and erecting 12V/42Ah SMF battery with battery terminal wire duly charged with 24 months warranty complete
Supplying and erecting iron work sheet metal work consisting of CRCA sheets various sections of iron plates chequered plates rods bars MS pipes etc. for panel board or any other purpose with bending cutting drilling and welding complete erected at the position with necessary materials duly painted with one coat of red oxide and two coats of enamel paint to match the switchgears or as per directions by the authority.
Supplying and erecting storage type water heater 15 litres capacity having standing loss <0.419 kWh / 24 hour / 45°C high impact resistance engineering plastic body with anti corrosive high grade steel inner tank heating element having hard water & corrosion protection with minimum 3 safety protections (i.e. thermostat & thermal cut-out multi function valve) with total pressure 8 bar withstanding capacity duly tested and marking sr. no. and date of erection complete. specification no. AP-WH/STWH
Supplying and erecting ultra violet water purifier with softener for safe drinking water consisting of UV germicidal tube of 8W capacity choke made of copper wire two indicator lamps dual function cartridge with output of purified water 1 litre/min with activated carbon filter and softener operating on 230V single phase A.C. supply with UV fail & filter change indication system.
Supplying, erecting, testing and commissioning of self contained water cooler 230/250V 50Hz nominal cooling capacity of 80 litres per hour and storage capacity 120 litres with partially stainless steel body as per specification no. AP-WCR/WC22
Supplying and erecting PVC insulated PVC round sheathed 1.5 sq.mm (30 no. x 0.25 mm dia.) 3 core flexible multi stranded copper Industrial cable for voltage grade up to 1.1 kV
Supplying and erecting integrated LED street light fitting 60W IP65 & IK08 class having single piece pressure die-cast aluminium housing having system lumens output of Min. 6600 Lumens min. efficacy of 110 lumen/W CRI>70 CCT upto 6500K THD<10% p.f. >0.95 operating range of 140-270V inbuilt surge protection of 10 kV Life class of 50 000 Hrs. at L70B50 including driver complete with 3 Years warranty as per specification No FG-ODF/FLS2.
Providing and erecting 6 m high (clear height) galvanised octagonal pole with foundation bolts having bottom of 130 mm A/F top 70 mm A/F on provided foundation as per specification no. OH-PL/OPL
Providing pipe type earthing with 40mm. dia. G.I. pipe or 20 mm dia. G.I. Rod complete with all materials testing and recording the results as per specification no. EA-EP
Making M- 20 grade reinforced cement concrete foundation by considering the safe soil bearing capacity at site as 10 T/sq.m at 1.5 m depth including supply of steel concrete excavation and fixing provided nut bolts with the help of template duly plastered as per design complete (for 6m to 8m high octagonal /conical GI pole).
Providing and erecting galvanised 1000mm single arm sword type bracket with FRP dome and ball as per specification no. OH-PL/PBKT
Supplying, erecting & terminating FR XLPE insulated galvanised steel formed wire armoured (strip) cable 1100 V 4 core 16 sq. mm. aluminium conductor complete erected with glands & lugs on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL
Supplying, erecting & terminating FR XLPE insulated galvanised steel formed wire armoured (strip) cable 1100 V 4 core 6 sq. mm. aluminium conductor complete erected with glands & lugs on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL
Supplying and erecting integrated LED flood light fitting Max. 70W IP65 & IK07 class having pressure die-cast aluminium housing having system lumens output of Min. 8400 Lumens min. efficacy of 120 lumen/W CRI>70 CCT upto 6500K THD<10% p.f. >0.90 operating range of 140-270V inbuilt surge protection of 4 kV Life class of 50 000 Hrs. at L70B50 including driver with U shaped bracket with 3 Years warranty as per specification No FG-ODF/FLS2.
Supplying and erecting Concealed type foot/step light Max. 5W having IP67. IK10 rated Pressure die cast housing having system lumens output of Min. 500 Lumens min. efficacy of 100 lumen/W CRI>80 CCT upto 5000K Beam Angle of 110 deg. THD<10% SDCM<5 p.f. >0.95 operating range of 230-270V surge protection of 2.5 kV Life class of 25 000 Hrs. at L70B50 including driver by making necessary arrangement/recess in wall to make it flush with surface with 2 Year warranty.
Supplying and erecting integrated LED round burial light 6W IP65 & IK10 class having pressure die-cast housing having system lumens output of Min. 500 Lumens min. efficacy of 85 lumen/W CRI>80 CCT upto 6500K THD<10% p.f. >0.90 operating range of 100-240V inbuilt surge protection of 4 kV Life class of 50 000 Hrs. at L50B50 including driver salt spray tested for 500 Hrs. including making of recess of appropriate size for flushing into surface with 2 Year warranty as per specification No FG-ODF/FLS2.
Supplying and erecting integrated LED Bollard Cylindrical/Cubical shaped 500mm 8W IP65 & IK10 class having extrusion aluminium housing with polycarbonate diffuser having system lumens output of Min. 800 Lumens min. efficacy of 100 lumen/W CRI>80 CCT upto 6500K THD<10% p.f. >0.90 operating range of 140-240V inbuilt surge protection of 2 kV Life class of 25 000 Hrs. at L50B50 including driver complete with 2 Year warranty as per specification No FG-ODF/FLS2.
Supplying, erecting and marking SPMCB 0.5A to 5A C-series with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB
Supplying and erecting FRP box of size 300mm x 200mm x 125 mm 2.7 mm thick complete on pole/wall as per specification No. CB-SB
Supplying, erecting & terminating FR XLPE insulated galvanised steel formed wire armoured (strip) cable 1100 V 4 core 6 sq. mm. aluminium conductor complete erected with glands & lugs on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL
Supplying and laying (including excavation) of suitable width & depth up to 90 cm) 50 mm outside dia. double wall corrugated pipes (DWC) of HDPE for enclosing cable below ground/road surface to required depth complete.
Supplying and laying (including excavation) of suitable width & depth up to 90 cm) 200 mm outside dia double wall corrugated pipes (DWC) of HDPE for enclosing cable below ground/road surface to required depth complete.
Supplying and laying (including excavation) half round reinforced cement concrete pipe of IS 458 2003 NP-2 class of 150 mm internal diameter in proper line level and slope including providing and fixing collars in cement mortar 1 2 and curing etc. complete.
Supplying and erecting minimum Three & above star rated submersible pump set of 5.625 KW/7.5 HP with 415 V 50 c/s AC supply suitable for 150 mm dia. borewell suitable for 100 to 400 LPM discharge at 132 to 27 m head & discharge & delivery pipe of Size-50 mm diameter with a necessary H type clamps as per specification No. WP-SMP
Supplying and erecting flat flexible 3 core 6 sq.mm PVC sheathed submersible type copper cable suitably clamped at fixed intervals with column pipe assembly complete.
Supplying and erecting automatic control panel for 3 Ph 415 volt A.C. Submersible/centrifugal pump set up to 7.5 HP - 10 H.P. consisting of DOL starter having relay range 28-42 AMP S.P.P. Combined ammeter/voltmeter phase indicating lamp enclosed in CRCA powder coated Vibration proof enclosure with IP 54 protection. Control Panel should offer single phasing phase reversal phase imbalance etc.
Supplying, erecting & terminating FR XLPE insulated galvanised steel formed wire armoured (strip) cable 1100 V 3½ core 25 sq. mm. aluminium conductor complete erected with glands & lugs on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL
Supplying, erecting & terminating FR XLPE insulated galvanised steel formed wire armoured (strip) cable 1100 V 3½ core 35 sq. mm. aluminium conductor complete erected with glands & lugs on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL
Supplying, erecting & terminating FR XLPE insulated galvanised steel formed wire armoured (strip) cable 1100 V 3½ core 50 sq. mm. aluminium conductor complete erected with glands & lugs on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL
Supplying, erecting & terminating FR XLPE insulated galvanised steel formed wire armoured (strip) cable 1100 V 3½ core 70 sq. mm. aluminium conductor complete erected with glands & lugs on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL
Supplying, erecting & terminating FR XLPE insulated galvanised steel formed wire armoured (strip) cable 1100 V 3½ core 95 sq. mm. aluminium conductor complete erected with glands & lugs on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL
Supplying, erecting & terminating FR XLPE insulated galvanised steel formed wire armoured (strip) cable 1100 V 3½ core 120 sq. mm. aluminium conductor complete erected with glands & lugs on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL
Supplying, erecting & terminating FR XLPE insulated galvanised steel formed wire armoured (strip) cable 1100 V 3½ core 150 sq. mm. aluminium conductor complete erected with glands & lugs on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL
Supplying, erecting & terminating FR XLPE insulated galvanised steel formed wire armoured (strip) cable 1100 V 3½ core 185 sq. mm. aluminium conductor complete erected with glands & lugs on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL
Supplying, erecting & terminating FR XLPE insulated galvanised steel formed wire armoured (strip) cable 1100 V 3½ core 300 sq. mm. aluminium conductor complete erected with glands & lugs on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL
Supplying, installing, testing and commissioning of booster fire pump [BP] suitable for water discharge of 450 LPM at 35 m head driven by electric motor 415 volts 3 phase 50 Hz AC supply of 5.5 kW or of suitable kW capacity for manual/automatic operation and consisting of following (a) Horizontal/vertical type single/multi stage centrifugal casing pump of cast iron body & bronze/CI impeller with stainless steel shaft (SS410 grade) mechanical seal conforming to IS 1520. (b) Squirrel cage induction motor TEFC synchronous speed 3000 RPM suitable for operation with IP 55 protection for enclosure horizontal foot mounted type with Class-'F' insulation conforming to IS-325. (c) M.S. fabricated common base plate coupling coupling guard foundation bolts etc. as required. (d) Erected on provided suitable size cement concrete foundation duly plastered with anti vibration pads with perfect aligning proper levelling complete pump set with accessories duly painted with two coats of synthetic enamel paint of fire red colour over a coat of primer (ISC code 536 as per IS 2932 of 2003) complete as per specification no. FF-MFP/BP
Supplying and erecting G.I. pipe ‘C’ class ERW 150 mm dia with necessary fittings complete as per specification no. FF-PP
Supplying and erecting 150 mm dia. cast iron double flange sluice valve complete with PN16 pressure rating as per specification no. FF-VL/SV
Supplying and erecting 150 mm dia. cast iron double flange butterfly valve of size complete with PN16 pressure rating as per specification no. FF-VL/BFV
Supplying and erecting 150 mm dia cast iron double flange NRV complete with PN16 pressure rating as per specification no. FF-VL/NRV
Supplying and erecting stainless steel single outlet hydrant valve fitted with necessary accessories complete as per specification no. FF-VL/HV
Supplying and installing wall mounting swinging hose reel drum fitted with 19 mm dia. 30m long high pressure polypropylene (Polyhose) along with necessary accessories complete as per specification no. FF-FFA/HV
Supplying and erecting 63mm dia reinforced rubber lined (R.R.L.) hose pipe 15m in length fitted with necessary accessories complete as per specification no. FF-FFA/RRL
Supplying and erecting stainless steel branch pipe 63 mm dia fitted with 20 mm dia detachable hexagonal nozzle complete as per specifications no. FF-FFA/NZ
Supplying and erecting brass orifice plate having 6 mm. thickness 140 mm outer dia with required diameter of inner hole at every single outlet hydrant valve as per specification no. FF-FFA/OP
Supplying and erecting M.S./CRCA cabinet for housing Floor Hydrant valve hose pipe hose reel and branch pipe (size 1000 x 736 x 736 mm.) made from 16 SWG sheet and angle iron 25 x 25 x 4 mm. having front doors with viewing glass (8 x6 ) and locking arrangement with necessary fixing material such as rubber bidding etc. duly painted in post box red colour( Code 538 of IS 5)
Supplying, installing, testing and commissioning of heat detector with combination ROR and Fixed Temp. complete as per specification no. FF-FAS/HD
Supplying, installing, testing and commissioning of optical type smoke detector on suitable back box with necessary connections complete as per specification no. FF-FAS/SD
Supplying, installing, testing and commissioning of manual call point (Pill box) with break glass push button (resettable type) in metal enclosure complete as per specification no. FF-FAAS/MCP
Supplying, installing, testing and commissioning of hooters having high (100dB 1m) and low (94dB 1m) volume setting group addressing facility allowing multiple sounders to be activated with CRCA enclosure complete as per specification no. FF-FAAS/HTR
Supplying, installing, testing and commissioning of FRLS armoured cable 2 core 1.5 sq.mm. copper conductor complete erected on wall/ ceiling complete as per specification no. CB-LT/CU
Supplying, installing, testing and commissioning of FR XLPE armoured cable 4 core 1.5 sq.mm. copper conductor complete erected on wall/ ceiling complete as per specification no. CB-LT/CU
Supplying, installing, testing and commissioning of 2 Zones Microprocessor based conventional fire alarm control panel (FACP) with standard accessories 16x2 Character LCD Display provision for zone wise contact and beep sound alarm suitable to operate on 120-220 V AC 0 - 49 Deg C 93 ± 2 Percentage RH (non- condensing) at 32 ± 2 Deg C complete as per specification no. FF-FAAS/FACP
Supplying, installing, testing and commissioning of 2 Zone local signal control panel (LCP) with standard accessories complete as per specification no. FF-FAAS/LCP
Supplying and erecting Carbon Dioxide (CO2) fire extinguisher of 4.5 kg. capacity cartridge type conform to IS 2878 /15683 complete erected with necessary clamp made from 50 x 6 mm. M. S. flat with nut & bolts routed in wall complete.
Supplying and erecting ABC powder type fire extinguisher as per IS 13849 /15683 of 6 kg capacity with necessary clamp for erection on wall
Providing Round bottom fire bucket of 9 Litres capacity as per IS 2546 made out of 24 gauge G.I. sheet with extra handle at bottom duly painted white inside and red outside with FIRE Mark on provided stand/ wall hook complete.
Providing Floor mounting stand for keeping 4 Nos. of FIRE buckets 1500mm in length 900mm in height frame made out of 30x30x4 mm angle iron with cross supports for legs welded with 4 hooks and duly painted with one coat of red lead and two coats of silver paint complete.
Supplying and erecting modular type switch 16A duly erected on provided plate and box with wiring connections complete.
Supplying and erecting modular type 3 pin 6 / 16A multi socket with safety shutter duly erected on provided plate and box with wiring connections complete.
Supplying and erecting PVC Surface modular switch box with double mounting plate for 3 module duly erected.
Supplying and erecting bulk head LED fitting max. 10W with high transitivity diffuser with system lumens output of min. 1100 lumens min. efficacy of 110 lumen/W CRI>80 CCT upto 6500K Beam Angle of 120 deg. THD<10% p.f. >0.95 operating range of 140-260V in built surge protection of 2.5 kV Life class of 50 000 Hrs. at L70B50 including driver IP66 IK09 rated on provided PVC Block / wooden board with 3 years warranty.
Supplying, erecting and marking TPMCB 40A to 63A with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB
Supplying and erecting single pole and neutral distribution board (SPNDB) with 2 ways for incoming and 10 ways (10 poles) for outgoing SP MCBs with door 1.2mm thickness surface / flush mounted IP 43 Protection on iron / GI frame as per specification no. SW-SWR/MCBDB
Supplying, Erecting and Commissioning of 2 pole RCCB 16/25A electromagnetic type with 30/100/300 mA sensitivity with earth leakage trip indication complete as per specification no. SW-RCCB/RCCB
Supplying, Erecting and Commissioning of 4 pole RCCB 40A electromagnetic type with 30/100/300 mA sensitivity with earth leakage trip indication complete as per specification no. SW-RCCB/RCCB
SITC of Electric Traction Passenger Lift with · Rated capacity :- 4 Passenger/272Kg · Floors :- G+1 floor (2 Stops/2 Landings) · Travel :- 3 to 4.2 mtrs · Location of Lift Machine:- MR/MRL · Rated speed :- 1.0 mps VS · Car/Landing door clear opening of 700/800 mm wide x 2000 mm high · Clear Car size of 1100.mm wide x 700.mm deep x 2250mm high · Lift shaft available having clear size of 1800 mm wide x 1200mm deep, 1500 mm Pit depth, 4150mm Overhead. · Doors type :- COPO/TOPO Doors with frame made from SS 304 grade solid (non-cladded) sheet of 1.5mm thick in hairline finish for car and all landing doors with SS door architraves/frames. The lift doors shall have minimum 1 hour fire rating (with submission of necessary valid test certificate issued by NABL accredited or Independent test laboratory). · Lift car enclosure made from SS 304 grade solid (non-cladded) sheet of 1.5mm, thick with hairline finish with frame made from MS girders, bracing of adequate size with minimum safety factor of 5, with Toe Guard Apron, with necessary false ceiling with adequate LED lights, blower/fan for ventilation & SS chequered plate flooring, handrails, mirror, emergency light etc. The lift car interior design shall be done as per the directions of engineer in charge. · COP with SS face plate having metallic push buttons with Braille code & luminous indicator around button with FPI, scrolling UP/DN LED indicator & with / without attendant key switch, OWD with audio-visual alarm, VAS in Marathi, Hindi & English with intercom system with telephone instrument in Lift car, LMR & FCC/ground floor · LOP with SS face plate having recess/surface push button box for all landings with scrolling UP/DN LED indicator having metallic push buttons with Braille code & luminous indicator around button with CPI, Lift car arrival & next travel direction audio-visual indication at all landings. · Lift controller based on microprocessor/ PLC with VVVF Drive having closed loop control system, with IBMS compatible having necessary port. The controller shall have necessary protections such as overcurrent, overvoltage, over speed, overheat for all devices including lift motor and travel direction protection, protection for phase loss at input or output etc. various operation modes such as maintenance, change direction by attendant, full load bypass, VIP call operation, self levelling operation, call cancel facility, auto return to home landing, fireman evacuation operation, earthquake operation, door open/close operation from COP etc. The system can record information for minimum 30 latest faults, with real-time clock management and handheld keypad with LCD screen for view and setting of parameters. The control panel duly wired with proper size & strength, copper wire for power & control circuit, with provision for addition of floor/control card & allied accessories control panel having enclosure of 1.5mm CRCA sheet with powder coating with IP54 Protection class. · Lift controller based on microprocessor/ PLC with VVVF Drive having closed loop control system, with IBMS compatible having necessary port. The controller shall have necessary protections such as overcurrent, overvoltage, over speed, overheat for all devices including lift motor and travel direction protection, protection for phase loss at input or output etc. various operation modes such as maintenance, change direction by attendant, full load bypass, VIP call operation, self levelling operation, call cancel facility, auto return to home landing, fireman evacuation operation, earthquake operation, door open/close operation from COP etc. The system can record information for minimum 30 latest faults, with real-time clock management and handheld keypad with LCD screen for view and setting of parameters. The control panel duly wired with proper size & strength, copper wire for power & control circuit, with provision for addition of floor/control card & allied accessories control panel having enclosure of 1.5mm CRCA sheet with powder coating with IP54 Protection class. · ARD complete with necessary SMF VRLA batteries · Fireman controller having fireman switch at fire Landing. · CCTV surveillance system comprises of 2 nos minimum 2.0 MP FHD IP based vandal proof Dome camera in lift car & in LMR/inside lift shaft top aimed on lift machinery & controller with NVR kept in LMR/FCC with HDR data backup for min. 90 days with min. 18” FHD TV monitor, to be kept in FCC/LMR as directed by Engineer In Charge. · Lift Machine of Gearless PMSM of suitable kW with duty cycle of minimum 120 starts/hr (with submission of necessary valid test certificate issued by NABL accredited or Independent test laboratory), with Traction pulley, OSG, electromagnetic brakes, entire assembly mounted on adequate size girders duly fixed on LMR floor/ shaft walls complete with main/diverter traction sheaves, suspension wire ropes/belts of adequate size & strength · Other mechanical parts such as 'T' section adequate size guide rails for car & counter weight with brackets fasteners, counter weight frame with necessary blocks, buffers with necessary support arrangement, MS pit ladder etc. erected with necessary steel work. · Minor civil work such as alteration work if any necessary for erection of landing door frames and it's accessories e.g. sill, header, hole pass etc complete with plaster finish, civil work for erection buffers, erection of lift machinery, adequate size core cuts if required & scaffolding for erecting guide rails, providing and fixing steel girders/RCC work having adequate strength for mounting and hoisting lift machine etc. complete as per specification no. LFT. · General: - Job includes entire procedure of obtaining all necessary erection permissions & "License to Work the Lift" from Electrical Inspector(Lifts) with submission to the Engineer In Charge. · The above rate includes Fully Comprehensive AMC for one year from the date of commissioning.(17.1.1)
SITC of Electric Traction Passenger Lift with · Rated capacity :- 16 Passenger/1088Kg · Floors :- G+1 floor (2 Stops/2 Landings) · Travel :- 3 to 4.2 mtrs · Location of Lift Machine:- MR/MRL · Rated speed :- 1.0mps VS · Car/Landing door clear opening of 1000mm wide x 2000 mm high · Clear Car size of 1600 mm wide x 1600 mm deep x 2250mm high · Lift shaft available having clear size of 2400 mm wide x 2200 mm deep, 1800 mm Pit depth, 3950 mm Overhead. · Doors type :- COPO/TOPO Doors with frame made from SS 304 grade solid(non-cladded) sheet of 1.5mm thick in hairline finish for car and all landing doors with SS door architraves/frames The lift doors shall have minimum 1 hour fire rating (with submission of necessary valid test certificate issued by NABL accredited or Independent test laboratory). · Lift car enclosure made from SS 304 grade solid (non-cladded) sheet of 1.5mm, thick with hairline finish with frame made from MS girders, bracing of adequate size with minimum safety factor of 5, with Toe Guard Apron, with necessary false ceiling with adequate LED lights, blower/fan for ventilation & SS chequered plate flooring, handrails, mirror, emergency light etc. The lift car interior design shall be done as per the directions of engineer in charge. · COP with SS face plate having metallic push buttons with Braille code & luminous indicator around button with FPI, scrolling UP/DN LED indicator & with / without attendant key switch, OWD with audio-visual alarm, VAS in Marathi, Hindi & English with intercom system with telephone instrument in Lift car, LMR & FCC/ground floor. · LOP with SS face plate having recess/surface push button box for all landings with scrolling UP/DN LED indicator having metallic push buttons with Braille code & luminous indicator around button with CPI, Lift car arrival & next travel direction audio-visual indication at all landings. · Lift controller based on microprocessor/ PLC with VVVF Drive having closed loop control system, with IBMS compatible having necessary port. The controller shall have necessary protections such as overcurrent, overvoltage, over speed, overheat for all devices including lift motor and travel direction protection, protection for phase loss at input or output etc. various operation modes such as maintenance, change direction by attendant, full load bypass, VIP call operation, self levelling operation, call cancel facility, auto return to home landing, fireman evacuation operation, earthquake operation, door open/close operation from COP etc. The system can record information for minimum 30 latest faults, with real-time clock management and handheld keypad with LCD screen for view and setting of parameters. The control panel duly wired with proper size & strength, copper wire for power & control circuit, with provision for addition of floor/control card & allied accessories control panel having enclosure of 1.5mm CRCA sheet with powder coating with IP54 Protection class. · ARD complete with necessary SMF VRLA batteries. · Fireman controller having fireman switch at fire Landing. · CCTV surveillance system comprises of 2 nos minimum 2.0MP FHD IP based vandal proof Dome camera in lift car & in LMR/inside lift shaft top aimed on Lift machinery & controller with NVR kept in LMR/FCC with HDR data backup for min. 90 days with min. 20” FHD TV monitor, to be kept in FCC/LMR as directed by Engineer In Charge. · Lift Machine of Gearless PMSM of suitable kW with duty cycle of minimum 120 starts/hr (with submission of necessary valid test certificate issued by NABL accredited or Independent test laboratory), with Traction pulley, OSG, electromagnetic brakes, entire assembly mounted on adequate size girders duly fixed on LMR floor/ shaft walls complete with main/diverter traction sheaves, suspension wire ropes/belts of adequate size & strength · Other mechanical parts such as 'T' section adequate size guide rails for car & counter weight with brackets fasteners, counter weight frame with necessary blocks, buffers with necessary support arrangement, MS pit ladder etc. erected with necessary steel work. · Minor civil work such as alteration work if any necessary for erection of landing door frames and it's accessories e.g. sill, header, hole pass etc complete with plaster finish, civil work for erection buffers, erection of lift machinery, adequate size core cuts if required & scaffolding for erecting guide rails, providing and fixing steel girders/RCC work having adequate strength for mounting and hoisting lift machine etc. complete as per specification no. LFT. · General: - Job includes entire procedure of obtaining all necessary erection permissions & "License to Work the Lift" from Electrical Inspector(Lifts) with submission to the Engineer In Charge. · The above rate includes Fully Comprehensive AMC for one year from the date of commissioning.(17.1.8)
Supplying, installing, testing and commissioning of 3 phase 11/0.433 kV 50 Hz. 630 kVA Mineral oil immersed and naturally cooled outdoor type Copper wound without gas cushioning hermetically Sealed transformer delta/star connected additional neutral brought out on load side temperature rise should not exceed 45? by thermometer in oil and 50? by the resistance method in winding at full load rating using type A winding insulation (kraft paper) with HV tapping (with off load tap changer) off load +5 to -10 in steps of 2.5% having 7 number of tap positions with standard accessories complete with test certificate with losses below 1860 Watts at 50% load 5300 Watts at 100% load as per IS 1180 (part 1) 2014 with necessary permissions of Electrical Inspector as per specification no SS- TR-SL.
Supplying, erecting, testing and commissioning of 11KV HT metering cubical (compact / vertical type) approved by MSEDCL / licensee fabricated with 2 mm (14 SWG) M.S. sheets with supporting angle painted with powder coating / epoxy paint of required shade copper bus bar size 25 x 6 mm heavy duty mechanical lock with counter meter for measuring no of times the opening of meter door top side cover (CT PT cover) interlock with meter door epoxy casted 3 nos. CT having required ratio between 10/5A to 50/5A VA10 or 15 Class 0.5S epoxy casted 3 nos. PT having ratio 11000/V3/110/V3 VA 50 Class 0.5 suitable for provided trivector meter and provision for incoming and outgoing cables complete duly tested by licensee with necessary test certificates and erected on provided plinth/ cc foundation.
Supplying, installing, testing and commissioning of 11kV 630A 21kA/3sec 2 way Indoor/outdoor extensible motorised SCADA compatible RMU internal arc tested consisting of 1 no. feeder with 1 LBS and 1 no. feeder with 1 VCB compliant to IEC 62271 -100 2 00 and 102 as per specification no. SW-HTS/RMU SCADA
Supplying, erecting & terminating XLPE insulated galvanised steel formed wire armoured (strip) cable 11 kV(UE) 3 x 300 sq. mm. aluminium conductor laid in provided trench / pipe as per specification no. CB-HT
Providing and erecting Heat shrinkable indoor termination kit for 11 kV (UE)/ 22 kV ( E ) XLPE HT cable 3x240 to 400 sq. mm. with necessary material as per specification no. CB-JT/HT
Providing and erecting Heat shrinkable outdoor termination kit for 11 kV (UE)/ 22 kV ( E ) XLPE HT cable 3x240 to 400 sq. mm. with necessary material as per specification no. CB-JT/HT
Providing earthing with galvanized iron earth plate size 60 x 60 x 0.6 cm complete with all materials testing & recording the results as per specification no. EA-EP
Providing earthing with copper earth plate size 30 x 30 x 0.315 cm complete with all materials testing & recording the results as per specification no. EA-EP
Supplying and erecting GI strip of high purity required size used for earthing on wall and/or any other purpose with necessary GI clamps fixed on wall painted with bituminous paint with joints required. As per specification no EA-EP.
Supplying and erecting copper strip of high purity required size used for earthing on wall and/or any other purpose with necessary copper clamps fixed on wall painted with bituminous paint with joints required. As per specification no. EA-EP.
Supplying and fixing PVC synthetic elastomer electrically insulating mat with class B insulation conforming to IS 15652 – 2006 having 2.5 mm thickness up to 11 kV
diesel generating set with alternator of 200 kVA output continuous rating 3 Phase 415 V 50c/s 0.8 p. f. A.C supply a totally enclosed air cooled / liquid cooled multi-cylinder diesel engine developing suitable BHP at 1500 rpm with 10% overload for 1 hour in 12 hours along with standard accessories self-excited self-regulated screen protected alternator with static excitation system running at 1500 RPM as per IS 4722-2001 with voltage regulation +/- 5 % with performance class G2 and maximum fuel consumption 34.40 Ltr/hr 75% loading. Both the engine and alternator direct coupled on a common fabricated steel base frame and mounted on anti-vibrating pads with standard control panel comprising meters switchgears indicators connected with suitable wires/cables the complete set enclosed in composite Acoustic enclosure as fully assembled integral unit made of 16 SWG CRCA Sheet sound absorbing material to restrict sound level up to 75 dB(A) at 1.0 m provided with first filling of oil diesel not less than 300 Ltr etc. on provided M20 Grade CC Foundation as per specification no. GEN-DG
microprocessor based AMF panel suitable for diesel generating set of above 180 kVA up to 200 kVA capacity Three phase 415 Volts 50Hz A.C. with all standard features safeties etc as per specification no. GEN-AMF.
Supplying and erecting 100 kVAr 440 V 3 phase 50 Hz. Contactor Logic & Intelligent Relay micro APFC passive filter panel consisting of suitable steps of APP/MPP type capacitor units with Detuned (harmonic filter) reactors of suitable rating APFC panel shall be compliance to IEC 61439 and power quality IEC 61921 standard as per specification no CP-ED/APFC
Supplying, erecting & terminating FR XLPE insulated galvanised steel formed wire armoured (strip) cable 1100 V 3½ core 300 sq. mm. aluminium conductor complete erected with glands & lugs on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL
SITC of 6 WAY FEEDER PILLER having details as below The panel shall be comprising of following & IEC 61439 Panel with IP 65 suitable for outdoor installation should be fully ompartmentallised Floor mounted with M.S. Channel dully painted fabricated of 14/16swg CRCA sheets completely derusted chemically treated and powder coated with approved shade ON - Off Indicating LED lamp locking arrangements withdual source intelligent flush mounted panel meter three phase four wire (IPM) 415V CT/ PT site programmable class I flush mounted (96 x 96mm) meter with voltage current frequency power factor ON hrs kWh EB and DG set metering and LT current transformer with bar primary 50/5 to 1600/5 ratio with 15 VA burden with IOT Based metering stsyem and gateway included as per SLD having following items - (MSEDCL APPROVED)(RA With PWD) Main Incomer 1 Nos - 1000A 4P ACB EDO LSGI Protection with Microprocess based control for BMS compatibility. Outgoing 6 Nos 3 Pole MCCB 415V 400A (Ics=100% of Icu) with LSIG protection with provision of Shunt/ UV/ Trip. Compatibal to BMS
SITC of Mini Piller 2 having details as below The panel shall be comprising of following & IEC 61439 Panel with IP 65 suitable for outdoor installation should be fully ompartmentallised Floor mounted with M.S. Channel dully painted fabricated of 14/16swg CRCA sheets completely derusted chemically treated and powder coated with approved shade ON - Off Indicating LED lamp locking arrangements withdual source intelligent flush mounted panel meter three phase four wire (IPM) 415V CT/ PT site programmable class I flush mounted (96 x 96mm) meter with voltage current frequency power factor ON hrs kWh EB and DG set metering and LT current transformer with bar primary 50/5 to 1600/5 ratio with 15 VA burden with IOT Based metering stsyem and gateway included as per SLD having following items - (MSEDCL APPROVED)(RA With PWD) Main Incomer 1 Nos - 400A 4P MCCB LSIG Protection with Microprocess based control for BMS compatibility. Outgoing 4 Nos 3 Pole MCCB 415V 200A (Ics=100% of Icu) LSIG protection with provision of Shunt/ UV/ Trip BMS compatibility.
SITC of Mini Piller 3 having details as below The panel shall be comprising of following & IEC 61439 Panel with IP 65 suitable for outdoor installation should be fully ompartmentallised Floor mounted with M.S. Channel dully painted fabricated of 14/16swg CRCA sheets completely derusted chemically treated and powder coated with approved shade ON - Off Indicating LED lamp locking arrangements withdual source intelligent flush mounted panel meter three phase four wire (IPM) 415V CT/ PT site programmable class I flush mounted (96 x 96mm) meter with voltage current frequency power factor ON hrs kWh EB and DG set metering and LT current transformer with bar primary 50/5 to 1600/5 ratio with 15 VA burden with IOT Based metering stsyem and gateway included as per SLD having following items - (MSEDCL APPROVED)(RA With PWD) Main Incomer 1 Nos - 400A 4P MCCB LSIG Protection with Microprocess based control for BMS compatibility. Outgoing 6 Nos 3 Pole MCCB 415V 200A (Ics=100% of Icu) LSIG protection with provision of Shunt/ UV/ Trip BMS compatibility.
SITC of Mini Piller 4 & Mini Pillar 5 having details as below The panel shall be comprising of following & IEC 61439 Panel with IP 65 suitable for outdoor installation should be fully ompartmentallised Floor mounted with M.S. Channel dully painted fabricated of 14/16swg CRCA sheets completely derusted chemically treated and powder coated with approved shade ON - Off Indicating LED lamp locking arrangements withdual source intelligent flush mounted panel meter three phase four wire (IPM) 415V CT/ PT site programmable class I flush mounted (96 x 96mm) meter with voltage current frequency power factor ON hrs kWh EB and DG set metering and LT current transformer with bar primary 50/5 to 1600/5 ratio with 15 VA burden with IOT Based metering stsyem and gateway included as per SLD having following items - (MSEDCL APPROVED)(RA With PWD) Main Incomer 1 Nos - 400A 4P MCCB LSIG Protection with Microprocess based control for BMS compatibility. Outgoing 9 Nos 3 Pole MCCB 415V 100A (Ics=100% of Icu) LSIG protection with provision of Shunt/ UV/ Trip BMS compatibility.
Supplying and installing cat-6 cable suitable for networking as per specification no. WG-COC/NC
Supplying, installing & testing UTP connector (RJ-45) as per specification No. WG-NAS/UTPC.
Supplying and fixing 9U wall mount rack (Dimension-DxWxH – 500x600x500 mm) as per specification No. WG-NAS/RAK
Supplying, fixing, and configuring 24 ports with 4 (SFP+) port ethernet managed switch with web view/CLI 6KV surge protection on ethernet port and console port for management in provided rack as per specification no. WG-NWC/GBS
Supplying and fixing 24 port patch panel with tool-less keystone jacks in provided U Rack complete as per specification no. WG-NAS/PP
Supplying & erecting of High definition 4/5 Megapixel IP IR Bullet Camera with following features Image Sensor minimum 1/2.8 Progressive Scan CMOS Video Resolution minimum 2592 x 1520 Video Compression H.264 H.265 or higher at least Three individually configurable stream Frame rate minimum 25 fps at all resolutions WDR minimum 120 dB Wide Dynamic Range ONVIF profile conformant minimum IR distance 50m Lens Type 2.8/4/6 mm Lens fixed focal Field of View 2.8 mm horizontal FOV 107° vertical FOV 57° diagonal FOV 129° 4 mm horizontal FOV 86° vertical FOV 47° diagonal FOV 102° 6 mm horizontal FOV 55° vertical FOV 29° diagonal FOV 65° Lux sensitivity- minimum 0.2 Lux at color minimum 0.05 Lux at Black & White 0.0 Lux (IR) Night Vision Distance minimum IR - 50m. Camera minimum Adjustment Angles - Pan 350° Tilt 72° Rotate 350°. Power Supply Support 12VDC & PoE IP67 IK10 - Vandal Resistant. Built in micro SD/SDHC/SDXC card slot of minimum 128 GB Built in microphone. minimum Input/Output - Audio in × 1 Audio Out × 1 Alarm in × 1 Alarm Out × 1. Image Settings Rotate mode saturation brightness contrast sharpness gain white balance. Image Enhancements Day/Night-Auto (ICR)/Color/Black & White 3D Digital Noise Reduction Automatic White Balance Automatic Gain Control Backlight Compensation Highlight Compensation.(NON CSR) (Warranty - 6 Months)
Supplying & erecting of High definition 4/5 Megapixel IP IR Dome Camera with following features Image Sensor minimum 1/2.8 Progressive Scan CMOS Video Resolution minimum 2592 x 1520 Video Compression H.264 H.265 or higher at least Three individually configurable stream Frame rate minimum 25 fps at all resolutions WDR minimum 120 dB Wide Dynamic Range ONVIF profile conformant minimum IR distance 50m Lens Type 2.8/4/6 mm Lens fixed focal Field of View 2.8 mm horizontal FOV 107° vertical FOV 57° diagonal FOV 129° 4 mm horizontal FOV 86° vertical FOV 47° diagonal FOV 102° 6 mm horizontal FOV 55° vertical FOV 29° diagonal FOV 65° Lux sensitivity - minimum 0.2 Lux at color minimum 0.05 Lux at Black & White 0.0 Lux (IR) Night Vision Distance minimum IR - 50m. Camera minimum Adjustment Angles - Pan 350° Tilt 72° Rotate 350°. Power Supply Support 12VDC & PoE IP67 IK10 - Vandal Resistant. Built in micro SD/SDHC/SDXC card slot of minimum 128 GB Built in microphone. minimum Input/Output - Audio in × 1 Audio Out × 1 Alarm in × 1 Alarm Out × 1. Image Settings Rotate mode saturation brightness contrast sharpness gain white balance. Image Enhancements Day/Night-Auto (ICR)/Color/Black & White 3D Digital Noise Reduction Automatic White Balance Automatic Gain Control Backlight Compensation Highlight Compensation. Events Privacy Masking Motion detection Scene change detection Face capture Video tampering audio exception detection Region entrance detection Region exiting detection. Operating temperature ( -30 to 60° C ) . Security - User account and password protection HTTPS IP filter IEEE 802.1X digest authentication user access log TLS1.2 AES - 256 SSH/Telnet closed FTP disabled. Protocol - DHCP UDP HTTP HTTPS NTP DNS RTP RTSP SMTP SSL/TLS TCP/IP Secure Real-Time Transport Protocol (SRTP) Bonjour SNMP and Secure shell (SSH) supported protocol. RoHS WEEE ISO-14001 and REACH
Supplying installing testing & commissioning of 32/40 Ch. Network Video Recorder (NVR) suitable connect Min. 32 IP Cameras up to 5 Megapixel Resolution with HDMI/VGA outputs provided HDMI output of 4K resolution or VGA output with output up to 1920 × 1080. Support H.265 or higher H.264 MJPEG Incoming Bandwidth 250Mbps with minimum 4 SATA Hard Disks ANR Technology 4 SATA interfaces for 4 HDDs and capacity of each HDD up to 8TB minimum 02 USB port Alarm I/O 16/4 RJ-45 10/100/ 1000 Mbps self?adaptive Ethernet interface ONVIF conformance Multiple network monitoring Web viewer . support protocol TCP/IP DHCP DNS DDNS NTP SADP SMTP NFS iSCSI UPnP™ HTTPS. RoHS UL CE FCC certified. duly erected in provided U Rack with wiring connections tagging and programming etc. complete as per specification no. CCTV-NVR
Supplying & erecting 8 TB internal Surveillance HDD suitable for SATA Port of NVR ( 16-6-21 )interface transfer rate 6 GB/S maximum sustained transfer rate 210 MB/Sec to 213 MB/S. Drive bay supported 08+ Cameras supported up to 64 Cache (MB) 256 Load/Unload Cycle -3000000 Work Load Rating per Year 180TB MTBF 1000000 Hrs. HTTPS. RoHS UL CE certified duly erected in position in provided NVR as per specification no. CCTV-HDD
Supplying & erecting 32 professional LED Monitor with 1920*1080 (Full HD) Display suitable for 16 channel NVR and following features Brightness minimum 250 Cd/m2 Contrast Ratio minimum 1000 1 Viewing angle 178/178 deg. Response time maximum 8 ms Inputs HDMI VGA BNC USB Audio In Built-in speakers maximum 2 W Suitable to operate on 100-240 V 50 Hz AC supply and 24/7 Duty Cycle duly erected on wall or table top with standard accessories like wall mount stand and wiring connections etc. complete as per specifications no. CCTV-MON(NON CSR)
Supplying Installing testing and commissioning of Supercardioid professional Wired Dynamic microphone with noiseless magnetic read switch frequency Response 50-18 000Hz Sensitivity 2.5mV/Pa Impedance 300? with quick detachable holder with 3-pin professional XLR connector & 10m twin core shielded low noise cable on provided stand complete as per specification no. PA-WDM
Supplying & erecting Microphone table/floor stand with height 350-530 mm base dia. min 150 mm min. weight 1.8 kg with superior quality of chrome plating/powder coating (resistant to rust & corrosion) having sturdy mechanism for ensuring trouble free movement and positioning of microphone complete as per specification no. PA-MTS
Supplying Installing testing and commissioning of Dual channel UHF wireless microphone & receiver including 2 handheld dynamic transmitters with operating range of minimum 30 mtr distance in line of sight between transmitter & receiver and with 2 x 1.5V batteries of suitable size and and Current consupmtion <150mA RF power output 10mW or higher suitable for frequency stability +/-0.005% frequency response 50-15000Hz channel frequency display & receiver with 220V-240V AC 50Hz AC Adaptor distortion /< 1% S/N ratio 100 dB suitable for same frequency as transmitter having controls like ON/OFF Switch Volume control for both channels LED indicators for RF & Audio Signal channel frequency displays & operates on 12V DC through an AC adaptor complete as per specification no. PA-DPA-UHF
Supplying installing testing & commissioning 2-Way flush mount Ceiling Speakers with input power 20W RMS power with power taps on 20/10/5W 100V & 70V line frequency response 90-18000Hz stylish metal mesh grill and plastic frame operates on 100V line for excellent reproduction of both speech and music wide frequency response and adjustable tweeter complete as per specification no. PA-FMCS
Supplying erecting testing and commissioning of multistrand annealed bare copper conductor transparent PVC insulated 2C x 1 sqmm speaker wire in provided trunking/conduit etc.complete as per specification no. PA-TSPWR
Supplying erecting testing and commissioning Conference Systems Chairman Unit with adjustable gooseneck microphone having minimum length (excluding pedestal) of 18.5' (470 mm) long 7.5 mV/Pa current consumption <50mA max mic auto switch off time 75 seconds input- line output- line headphone speaker- max input 300 mW Controls- Priority switch talk switch speaker volume control headphone volume control and facilities like After pressing the Priority Switch mute all active delegate unit with accessories such as foam windshield 2.5m interconnecting cables complete as per specification no. PA CSCU
Supplying erecting testing and commissioning Conference Systems Delegate Unit with adjustable gooseneck microphone having minimum length (excluding pedestal) of 18.5' (470 mm) 7.5 mV/Pa current consumption <50mA max mic auto switch off time 75 seconds input- line output- line headphone speaker max input 300 mW Controls- talk switch speaker volume control headphone volume control with accessories such as foam windshield 2.5m interconnecting cables complete as per specification no. PA-CSDU
Supplying installing testing & commissioning 2-Way flush mount Ceiling Speakers with input power 30W RMS power with power taps on 30/15/7.5W 100V & 70V line frequency response 90-18000Hz stylish metal mesh grill and plastic frame operates on 100V line for excellent reproduction of both speech and music wide frequency response and adjustable tweeter complete as per specification no. PA-FMCS
Supplying erecting testing and commissioning of multistrand annealed bare copper conductor transparent PVC insulated 2C x 0.5 sqmm speaker wire in provided trunking/conduit etc.complete as per specification no. PA-TSPWR
Supplyig erecting testing and commissioning Conference Controller Unit controlles up to 50 disscusion units with 50W PA Amplifier with robust metal case Line o/p- 17.5V DC/3A Max.-34dBV (20mV) minimum 2 or more inputs Headphone output 60-14000 Hz frequency response S/N ratio >60dB Speaker output 4? 8?/(Low Impedence) and 70V & 100V/(High Impedence) Digital recorder with LED indication bar can playback the pre-recorded messages suitable for 230V AC & 24V DC on provided 19 rack. Unit shall have the facility of feeding two independent groups of Delegate Units complete as per specification no. PA-CCU
S.S.Civil Projects Private Limited (BID ID -6564564)
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid