Karnataka Power Transmission Corporation Limited
chethana
Dismantling Transportation (to and fro) Repair,Testing,Erection and commissioning of sick power transformer of rating 100MVA, 220/110/11kV Voltage class, Power Transformer of NGEF make SL No 6800000058 YOM 1989 DOF30.04.2022 at 220kV SRS, Kavoor, Mangaluru percentage tender on total turnkey basis
KPTCL/2023-24/EL/WORK_INDENT187
KPTCL/2023-24/EL/WORK_INDENT187
Open
Electrical
Two Tender Document System(Two Cover)
KPTCL SEE Works and Mantainance Circle Mangalore
17 documents required · 16 mandatory · 1 optional
The Bidder shall have experience of minimum 05 (five) years in manufacturing / repairing, testing and commissioning of same or higher voltage class of Power Transformer herein tendered involving designing, manufacturing and replacement of faulty windings in case of Power Transformer which has been repaired for any of the Government / public sector power utility in India which should have been in satisfactory continuous operation for at least 02 (two) years prior to the date of opening of the tender.
he Bidder should have executed either manufacture or repair on total turnkey basis (involving designing, manufacturing and replacement of faulty windings of Power Transformer) of a same or higher voltage class in the past 10 (ten) years ending last day of the month previous to the one in which tender is invited for any of the Government / public sector power utility for any one of the following value of work which shall have rendered satisfactory service of at least 02 (two) years continuously. a)a minimum of 60% of the value of the tendered amount against each of 01(one) distinct work orders on total turnkey basis. OR b)a minimum of 50% of the value of the tendered amount against each of 03 (three) distinct work orders on total turnkey basis OR c)a minimum of 40% of the value of the tendered amount against each of 04 (four) distinct work orders on total turnkey basis
The Bidder shall have technically qualified work force with domain knowledge relating to design of Power Transformer including quality control and shall have infrastructure, testing and erection facilities and capacity to execute the works
The Bidder should have their own repair shop with all the facility such as Crane, Oven, winding machines, etc., required for carrying out necessary repairs on Power Transformers
The Bidder should have established own workshop to accommodate and repair EHV Transformers,and should maintain dust free environment for winding works and should have the essential equipment like a.40 Tons EOT crane for capacities up to 31.5 MVA and 100 Tons EOT crane for capacities beyond 31.5 MVA.b.At least 6 KL oil filtration plant.c.Winding machines for winding of Transformer windings.d.Insulating paper wrapping machine.e.Vacuum drying chamber to accommodate the active parts of the tendered Transformer.f.Fully Automatic Digital Insulation Tester (5 KV)g.Automatic Digital Capacitance and Tan delta measuring instrument.h.Digital winding resistance measurement instrument.i.Digital turns ratio meter.j.Power analyzer.k.Adequate rating of cables for measuring load losses and impedance as per IS.2026. l.Sufficient no. of sensors for measuring top and bottom oil temperatures shall be made available for testing of Transformers, and other essential T&P. m.Digital Flow meter for measuring the quantity of Transformer oil during filling.n.Generators/Transformers and Capacitor Banks and Instrument transformers of adequate rating for conducting Load loss, No load loss,separate source ,DVDF and Temperature rise Tests.o.Adequate rating of Impulse Generator for conducting Lightening Impulse Test
The Bidder shall upload the proof of having possessed the above T&P equipment along with valid calibration certificate for testing / measuring equipment to the e-portal for verification. The Repairers who do not possess the above equipment and valid calibration reports will be treated as non-responsive and their Bids will be rejected.
List of existing commitments and ongoing works
List of works for which tenders already submitted
The Bidder shall have necessary facilities at his own works for carrying out all routine tests mentioned in this specification including facility to carry out special tests namely Impulse Test and Temperature Rise Test on a repaired Power Transformer as prescribed in the latest IS:2026/1977 or any relevant standard as applicable for testing of repaired Power Transformer. The testing facilities shall have testing and measuring instruments calibrated by National Accreditation Board for Testing and Calibration Laboratories (NABL). Valid calibration reports of Testing and measuring instruments shall be uploaded to the e-portal.
As per tender documents
Banker Details for reference
Owing to the following key and critical equipment for this work(XXX,XXX,XXX)
List of Financial Resources with Certificates
Minimum Average Annual Turnover (MAAT) of the Bidder for best 03 (three) years out of last preceding 05 (five) financial years (on the date of tendering) ending on March shall not be less than 100% of the amount put to tender NOTE- In case Bidder is a holding company, MAAT shall be that of holding company only (i.e. excluding its subsidiary / group companies). In case Bidder is a subsidiary of a holding company, MAAT shall be that of subsidiary company only (i.e. excluding its holding company). 2. In support of the above, the Bidder has to upload and submit copies of PROFIT and LOSS ACCOUNT / BALANCE SHEET for last 05 (five) years along with latest Income tax clearance certificate. The Bidder shall furnish certified copy of the Annual Turn Over with balance sheet duly signed by the Chartered Accountant. 3.The firm should have sound financial capability. The solvency required will be 100% of the amount put to tender. The solvency certificate shall be from a nationalized or scheduled Bank and issued within a period 12 months from the final date of submission of tender. 4. Proof of PAN and Tax Registration number shall be furnished and uploaded.
Reports on the financial standing of the tenderer,
₹5,000
₹3.1 L
21 Feb 2024
21 Feb 2024
1 Apr 2024
21 Mar 2024
4 Mar 2024
Dismantling Transportation (to and fro) Repair,Testing,Erection and commissioning of sick power transformer of rating 100MVA, 220/110/11kV Voltage class, Power Transformer of NGEF make SL No 6800000058 YOM 1989 DOF30.04.2022 at 220kV SRS, Kavoor, Mangaluru percentage tender on total turnkey basis
Dismantling, Transportation (to and fro), Repair, Testing, Erection and commissioning of sick Power Transformer of rating 100MVA, 220/110/11KV Voltage class, Power Transformer of NGEF Make, Sl No. 680...
Dismantling, Transportation (to and fro), Repair, Testing, Erection and commissioning of sick Power Transformer of rating 100MVA, 220/110/11KV Voltage class, Power Transformer of NGEF Make, Sl No. 680...
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
Collecting_Paper_stamp_duty.pdf
Others - KPTCL Contract Agreement Circular • 0.60 MB
Techno commercial sheets.docx
Techno-Commercial Worksheet • 0.06 MB
Tender documents NGEF Kavoor.pdf
Tender Document • 1.39 MB
Price bid, only for reference purpose not to be upload.pdf
Others - Price sheet only for reference • 0.11 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .