| 1 | L1₹30.4 LAccepted-AOC BUNGLOW NO 1 RAJPOOT VILLA BARARU ROAD PATKUYI BARARU SAGAR MP 470002 | SAGAR | SAGAR | MADHYA PRADESH | 470002 | L1 | Accepted-AOC aoc | |
| 2 | L2₹34.9 L+₹3.3 L (10.3%)Rejected-Finance ANAND NAGAR ROAD NO 4 RAJAKHEDI MAKRONIA SAUGOR MP | SAUGOR | SAUGOR | MP | L2 | Rejected-Finance 2nd lowest bid | |
| 3 | L3₹36.8 L+₹5.2 L (16.3%)Rejected-Finance | L3 | Rejected-Finance 3rd lowest bid | |
| 4 | L4₹36.8 L+₹5.2 L (16.4%)Rejected-Finance | L4 | Rejected-Finance 4th lowest bid | |
| 5 | L5₹37.4 L+₹5.7 L (18.1%)Rejected-Finance | L5 | Rejected-Finance 5th lowest bid |
Tender Value
₹40 L
EMD Value
₹80,000
Closing Date
27 Jun 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE SAUGOR
GE SAUGOR
COMPREHENSIVE MAINT OF SEWAGE LINE, SEPTIC TANK, SOAKAGE WELL AND REPAIR, MAINT OF B/R WORK IN MES BLDGS AND OTHER BLDGS IN AGE B/R-I AREA UNDER GE SAUGOR.
2022_MES_527292_1
GE/SGR/TOK-28 OF 2022-23
Open Tender
Civil Works
Item Rate
180 days
SAUGOR
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
GARRISON ENGINEER SAUGOR
₹80,000
Yes
30 Jun 2022
3 Jun 2022
29 Jun 2022
3 Jun 2022
27 Jun 2022
15 Jun 2022
60 days
Amount
Cleaning of septic tank of any capacity by mechnical means including vaccume suction, taking off suitable capacity fitted with vaccume sunction pump of capacity not less than 15 cum/hr and deposited the sludge and water outside the MOD land complete all as specified and directed upto entire satisaction of Engr-in-charge.
Taking down cement plaster on brick or stone walls, ceiling , chajja etc. including raking out joints, hacking for key, scrubbing down with water complete all as specified and directed.
M&L for brickwork with subclass 'B' old size bricks, straright or curved on plan exc 6m mean radius built in cement mortar 1:4 using bricks of crushing strength not less than 35 Kg/cm2 including demolition of brick work or rubbled stone masonry including all qoins arches , pillars etc built in cement mortar complete all as specified and directed.
M&L for brick work with sub class 'B' brick in cement mortar 1:4, straight or curved on plan to any radius in half brick thick wall including demolition of brick masonry, built in cement mortar incl all quoins, arches, pillars, etc and removing of rubbish off the premises complete all as specified and directed.
M&L for brick bats using subclass 'B' bricks for loose filling in soak wells complete all as per specified and directed.
M&L for cutting into existing manholes for (dia 150mm / 200mm) connecting new or old drains making good to pipes and rendering, cutting out existing benching for and forming branch channel (1/2 round or 3/4 section) in cement concrete 1:2:4 type B1 smooth finished and reforming benching as required all as specified and directed
M&L for rendering 15mm thick cement plaster in cement mortar 1:4 on brick work / concrete surfaces finishing the surfaces even and smooth with out using extra cement complete all as specified and directed.
S&F in replacement 110mm bore PVC(SWR) pipes single soketed in any length with adhesive jointed fixed to wall with mild steel clamps complete all as specified and directed.
All as per Srl item No 8 here -in-before but laid in trenches or in floors complete all as specified and directed
S&F in replacement 75mm bore PVC(SWR) pipes single soketed in any length with adhesive jointed fixed to wall with mild steel clamps complete all as specified and directed.
All as per Srl item No 10 here -in-before but laid in trenches or in floors complete all as specified and directed..
S&F PVC (SWR) bends 110 mm dia complete all as specified and directed.
S&F PVC (SWR) bends of bore 110mm with access door complete all as specified and directed.
S&F PVC (SWR) bends 75 mm dia complete all as specified and directed.
S&F PVC (SWR) bends 75 mm dia with acess door complete all as specified and directed.
S&F PVC (SWR) junction single ( single T ) equal or unequal 110mm dia complete all as specified and directed.
S&F PVC (SWR) 110mm dia junction, with acess door single(single 'T') equal or unequal complete all as specified and directed .
S&F in repair for 75mm dia PVC ( SWR) floor trap with grating including jointing with solvant cement including PCC 1:2:4 and making good the existing floor complete all as specified and directed.
S&F PVC (SWR) vent cowl 110mm dia complete all as specified and directed.
Demolition of RCC of roof, beams, landing, chajja, cover slabs and similar suspended work complete all as specified and directed.
Demolition of cement concrete of any description and in any position complete all as specified and directed.
M&L for RCC 1:2:4, type B-1 (using 20mm graded stone aggregates) as in slabs supported on walls as in soak well and septic tank complete all as specified and directed.
M&L for pre-cast reinforced cement concrete 1:2:4, type B-1 (using 20mm graded stone aggregates) as in cover slab of mane hole set in cement mortar 1:4 complete all as specified and directed.
M&L for form work to soffits of suspended slabs such as flat or curved roof slabs, floor slabs n exc 200mm thick finished fair or curved concrete surface complete all as specified and directed..
M&L for form work to edges of concrete flats, treads breaks in floors, window cills, concrete railings, openings in concrete walls, floor and roofs not exc 10cm wide and sides of RCC / PCC bands in walls, horizontal or slopping and similar works fair finished concrete surface complete all as specified and directed..
M&L for mild steel TMT bars 10 mm dia and over cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed.
M&L for mild steel TMT bars 6 to 8 mm dia cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips quality complete all as specified and directed.
M&L for mild steel round bars 10mm dia & over,cut to length, bent to shape required, including cranking, bending as in manhole covers handles, steps, rungs etc complete all as specified and directed.
M&L for cement concrete 1:4:8, type D 2 (using 40 mm graded stone aggregates) as in foundations, filling and mass concrete complete all as specified and directed.
Excavation in trenches not exc 1.5 m wide, not exc 1.5 m deep in soft/ loose soil for foundation etc or for shaft, wells, manholes etc not exc 10 Sqm on plan and not exc 1.5 m in depth and getting out complete all as specified and directed.
All as per Srl item No.30 above but exc 1.50 M depth but not exc 3.00m depth -ditto-
Removing excavated soil exceeding 500 m distance and n exc 1.50 km depositing where directed at alevel not exc 1.5 metre above the starting point complete all as specified and directed.
Returning ,filling in including spreading ,levelling watering and well ramming with soil in layers not exc 25 cm thick complete all as specified and directed.
S&F HDPE double wall corrugated sewage pipe of 150mm internal bore SN-8 as per IS 16908 Part-II 2013 of following sizes laid in trenches, jointed and tested as per manufacturer instruction including demolition and breaking up drain pipes (salt glazed ware)/ RCC pipe of existing bore pipe set in cement mortar complete all as specified and directed
S&F HDPE double wall corrugated sewage pipe of 200mm internal bore SN-8 as per IS 16908 Part-II 2013 of following sizes laid in trenches, jointed and tested as per manufacturer instruction including demolition and breaking up drain pipes (salt glazed ware)/ RCC pipe of existing bore pipe set in cement mortar complete all as specified and directed
M&L for PCC 1:2:4 type B-1 (using 20mm graded stone aggregates) as in copings/ bands and benching,floors and the like including weathering, slightly rounded or chamfered angles and throating complete all as specified and directed.. .
M&L brick work with sub class 'B' old size bricks straight or curved on plan exc 6 m mean radius built in CM 1:6 including demolition of brick masonry, built in cement mortar incl all quoins, arches, pillars, etc and removing of rubbish off the premises complete all as specified and directed.
M&L for walling of random rubble stone masonry, brought upto courses, well bonded, bedded and solidly hearted, built in cement mortar (1:6) complete all as specified and as directed
M&L for prepration of newly plastered wall sufaces & applying two coats exterior emulsion weather proof paint over one coat of exterior wall primer complete all as specified and directed by Engr-in-charge. Make:- Asian ACE or equivalent make as approved by GE
Dismantling timber scantlings 40 sqcm and over in section, in any position complete all as specified and directed.
M&L for mild steel rolled sections/hallow section as in main and cross beams, hip and jack rafters; purlins Posts where connected to common rafters and angle cleats or other connecting plates incl wind ties etc Fe410 Gde E-250) Quality A complete all as specified and directed
S&F 6mm thick Asbestos cement, corrugated or semi corrugated sheets in roof, walls etc fixed with J / L bolts including dismantling of Asbestos cement ( corrugated, semi corrugated, ec) sheets roofing complete all as specified and directed
Taking down and refxing Asbestos cement, corrugated or semi corrugated sheets in roof complete all as specified and directed
S&F 6mm thick Asbestos cement two piece adjustable plain wing ridge fixed with J / L bolts including dismantling of Asbestos cement ( corrugated, semi corrugated, ec) sheets roofing complete all as specified and directed
S&F framed work as in doors or gates of angle or other section with gusset plates, rails, braces, etc., complete, drilled for fixing of steel sheeting or other covering. Doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing complete all as specified and directed
M&L for applying two coats of synthetic enamel paint over a coat of red oxide primer on steel and iron surfaces of any description over 10 cm in width or girth not otherwise described including preparation of new steel surfaces complete all as specified and directed
M&L for suspended false ceilling comprising of 4mm thick non asbestos fibre cement bulding boards of size 595mmx595mm, fixed or laid/inserted to powder coated GI frame work with screws over GI perimeter channel 0.55mm thick with two unequal flanges of 20 and 30 mm and web of 27 mm fixed to sourrounding wall using nylon sleeves and screws at 450mm centre to centre/ intermediate channel 0.9 mm thick having two equal flanges of 15mm each and web of 45mm suspended from soffit at approx 900mm centre to centre with GI cleat and steel expansion fastners with and including ceiling section (not exc 1.2m length) of 0.55mm thickness having kurled web of 50mm and flange of 26mm each with lips of 10.5 mm fixed to the intermediate channel with connecting clips across the intermediate channel at 457 mm center to centre including hangers 4mmm dia GI (upto 1200mm length) adjusting level fixed to roof slabs by means of ceiling cleats made out of GI flat 40x3mm size 60mm long incl dismantling of any type or ceiling boards in thickness incl cover fillets including dismantling of any type of ceiling boards in any thickness incl cover fillets etc. complete all as specified and directed. Make : Everest (Lake and Hill) or equivalent make as approved by GE
M&L for 25 mm thick cement concrete 1:2:4, type B-1 (using 20 mm graded stone aggregates) as in levelling course of sub base finished even and rough to receive the topping layer complete all as specified and directed.
M&L for vitrified ceramic tile, light shade 10 mm thick (square/rectangular) polished area of each tile not exc.0.36 sqm as in floors etc, set and jointed in neat cement slurry and pointed in white or coloured cement to match laid over and including 15mm thick screed bed in CM (1:6) including dismantling of floor, hearth tiling including cement mortar bedding and removing of rubbish off the premises complete all as specified and directed
All as per Srl item No.49 above but as in dado / skirting etc laid over and including 10 mm thick rendering in CM 1:4 including dismantling of wall tiling including cement mortar bedding and removing of rubbish off the premises -ditto-
M&L for coloured anti skid ceremic tiles 7 to 8 mm thick area of each tiles exc. 0.06 sqm and not exc. 0.11 sqm as in floor set & jointed in neat cement slurry and pointed in white cement mixed with pigment to match laid over and including 15 mm thick screed bed in CM 1:6 including dismantling of floor, hearth tiling including cement mortar bedding and removing of rubbish off the premises complete all as specified and directed
M&L for glazed ceramic joint free coloured tiles on vertical surfaces size 350mmx 250mmx 7mm/ 450mmx 350mmx 7mm thick laid over & including 10mm thick rendering in CM 1:4 set and jointed in neat cement slurry and pointed in white/coloured cement to match the shade /colour of tiles including dismantling of wall tiling including cement mortar bedding and removing of rubbish off the premises complete all as specified & directed.
Taking down chowkats or frames with shutters (without taking off shutter from frames) not exc. 1.5 sq. m each complete all as specified and directed.
Taking down chowkhats or frame (with out taking off shutters from the frames) exc 1.50 Sqm but n exc 4 Sqm each with shutters complete all as specified and directed
Taking down shutters of any description exc 1 Sqm but not exc. 2 Sqm each complete all as specified and directed
Taking down shutters of any description not exc 1 Sqm complete all as specified and directed
M&L for second class hardwood plain, solid, straight chowkhat and frames wrought framed rebated on the solid, rounded on the solid or chamfered put together with glue pinned at joints complete all as specified and directed.
S&F 35mm thick flush shutters, solid core construction, with block board core and plywood face panels, commercial type on both sides complete all as specified and directed.
S&F 35mm thick factory made second class hardwood glazed and skeleton shutters open rebated and prepared to receive glass gauge etc (w/o sash bars) edges of farrming plain chamfered or rounded fitted with cut and mitred beads for securing glass etc ,size of member of shutter as specified in SSR Part -I ,section 8, Clause 8.20 (a) complete all as specified and directed.
S&F 30 mm thick factory made second class hardwood glazed and skeleton shutters open rebated and prepared to receive glass gauge etc (w/o sash bars) edges of farrming plain chamfered or rounded fitted with cut and mitred beads for securing glass etc ,size of member of shutter for windows, ventilators, etc. are provided with stiles and rails as specified in SSR Part -I ,section 8,clause 8.20 (b) supplied &fitted to chowkats complete all as specified and directed.
S&F steel ventilators with top hung shutter including two pairs of mild steel cup pivots, catch spring and pulley wheel complete all as specified and directed.
S&F sheet glass, 3.0 mm thick ordinary quality fixed wdn beads / oil putty in square not ex 0.50 sqm in each pane complete all as specified and directed.
S&F in repairs 3.0 mm thick Figured glass, pin head type and fixed wdn beads / oil putty in square not ex 0.50 sqm in each pane complete all as specified and directed.
S&F stainless steel wire cloth 0.36 mm nomiral dia and wire and average width of aperture 1.40 mm fixed with SS staples complete all as specied and directed.
S&F factory made PVC door frame of size 50 mm x 47 mm with wall thickness of 5 mm made out of extended 5 mm Prelam PVC sheet cut at corner and jointed with 02 Nos., 150 mm long brackets of size 15 mm x 15 mm mild steel square tubes 19 gauge including vertical door profiles reinforced with 19 mm x 19 mm steel square tube of 19 gauge (EPDM) rubber gasket weather seal provided through out the frame and fixed to wall with 65/100 mm long mild steel screws through the frame by using PVC fasteners (minimum of 04 Nos. of screws to be provided for each vertical number & minimum 02 Nos. for horizontal member), complete all as specified.
S&F factory made soild PVC moulded door shutter, 28mm to 30 mm thick (stiles) with wood free EPS with 2, 4 or 6 raised panel design with 2mm thick moulded prelam PVC sheet on the front face & 2mm thick plain colour sheet on back incl 3 Nos 100 mm stainless steel butt hinges complete all as specified and directed.
S&F in repairs stainless steel grill with fixing arrangement (wt. of grill not less then 2.50 kg/sqm), stainless steel wire mesh 0.45 mm dia etc including necessary cutting holes on wall and floor and confirming to IS complete all as specified and directed.
S&F in repairs vitreous china squatting pan “ORISSA” pattern size 580mm X 440mm, white with 'P' or 'S' trap front or back inlet with integral foot rest (excl flushing cistern & flush pipe) & including connection to trap & to flushing pipe anti syphonage pipe etc complete including making good to floor complete all as specified & as directed.
S&F in repairs PVC low level flushing cistern of 10 Ltr capacity including flushing pipe bend complete all as specified and directed.
S&F in repair vitreous China WHB white flat back size 550mmx400mm including Supplied and fixed angle iron brackets, C.P pillar tap fency type 01 No 15mm bore, CP waste coupling, 32mm dia and PVC waste pipe 32mm dia and PVC connection 450mm long high pressure complete all as specified & directed.
S&F in repairs brass chromium plated shower rose fancy type , as approved , with or without swivel joints, including fixing to steel pipe fixed complete all as specified and directed.
S&F in repair concealed stop valve , 15mm dia, cast copper alloy,CP fancy type with long shank and cup screwd down, high pressure ,screwed both ends for iron pipes or for unions and fixed in pipe complete all as specified and directed.
S&F in repair 15 mm dia angle cock external threaded,chromium plated, screwed down high pressure with crutch or butterfly handle, screwed both ends for iron pipe or for unions complete all as specified and directed..
S&F in repair bib taps, cast copper alloy chromium plated fancy type with crutch or butterfly handle, sc-rewed down, screwed for iron pipe or for brass ferrule of 15 mm bore and fixed complete all as specified and directed.
S&F in repair PVC connections 15mm bore size450 in length with both end brass/PVC high quality nuts complete all as specified and directed.
S&F in repair stainless steel plate rack of size 900mmx600mmx 250mm complete all as specified and directed.
S&F in repair sinks with drainage board made of stainless steel 1mm thick kitchen or laboratory with plugs, washers, Coupling and down take waste piple ; including bedding in CM on to dwarf wall or including fixing cantilever brackets and connecting union to pipe, overall size 915mmx460mm bowl size 410mm x 330mm x 160mm complete all as specified and directed.
M&L for 18mm to 20mm thick Granite slab of any shade ( table rubbed and polished ) machine cut for vertical surface of pillars, floor /shelves in steps, jambs, pillars, window cills& cooking plateforms over and including 20 mm thick screed bed or bedding layer of CM (1:4) including pointing in white/colour cement 1:2 using marble dust with admixture of pigment to match shade of the slabs laid bedded and pointed in any mortor including diasmantling existing Granite slabs complete all as specified & directed
M&L for machine cut Cudappah stone slab 20mm to 25mm thick over cement screed base, laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing including diasmantling existing Cudappah slabs complete all as specified and directed.
S&F MS butt hinges 100 mm size medium weight, coled rolled and fixed with screws complete all as specified and directed.
S&F MS butt hinges 125 mm size medium weight, coled rolled and fixed with screws complete all as specified and directed.
S&F stainless steel butt hinges 100 mm and fixed with screw complete all as specified and directed
S&F for 200mm size Aluminium anodised barrel tower bolt of extruded section and fixed with screws complete all as specified and directed
S&F extruded aluminium alloy handles, fabricated type., anodised Size of handle 150 mm fixed with steel screws complete all as specified and directed
S&F 250mm long Aluminium alloy anodised Sliding door both with hasp, staple( bolt type) and fixed clips of sheet , cast or extruded sections and fixing bolts and sliding of extruded sections or cast -aluminium alloy and fixed with steel screws complete all as specified and directed
M&L for cutting chases, pinning in, in brick wall making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc.; and cutting chases for concealed water tubing or concealed conduit wiring. etc. and making good, cutting not exceeding 10cm girth complete all as specified and directed.
S&F 15mm Galvanised Mild steel tubing medium grade galvanised with all fittings and fixed complete to walls and ceilings or laid in floors including taking down 15 mm dia GI tubing and connection complete all as specified and directed.
Taking down and refixing only 15mm GI tubing medium grade to walls and ceilings or laying in floors complete all as specified and directed.
S&F 20mm Galvanised Mild steel tubing medium grade galvanised with all fittings and fixed complete to walls and ceilings or laid in floors including taking down 20 mm dia GI tubing and connection complete all as specified and directed.
Taking down and re-fixing only 20mm GI tubing medium grade to walls and ceilings or laying in floors complete all as specified and directed.
S&F in repair tubular towel rail, brass chromium plated 20mm dia, D type, 60cm long between flanges complete all as specified and directed.
S&F 18mm/19 mm thick pre laminated paticle board, as in cupboards, shelves, pelmets etc sexterior grade, pre laminated one side decoraded choice lamination and other side balancing white lamination cut to required size and fixed to frame complete all as specified and directed
S&F 100mm long Hasp and Staple, safety type Aluminium with MS hinge pin incl bolt to hinge plate and fixed with screws complete all as specified and directed
M&L for applying one coat of systhetic enamel paint surfaces of any description, over 10cm width or girth, not otherwise described on old painted surface including preparation of old wooden surfaces complete all as specified and directed
S&F in repair Continuous (piano) hinges, Width of flaps (when open) - 30mm mild steel, bright finish or electrogalvanised complete all as specified and directed.
M&L for PCC 1:2:4, type B-1 (using 20mm graded stone aggregates) on roof top as a leveling course / padding to maintain the slope, finished the surface even and fair without using extra cement complete all as specified & directed .
S&F glass dividing strips, 3mm thick, 38mm width complete all as specified and directed.
M&L for point wiring for the following with 1.5 Sqmm PVC insulated FR, unsheathed, copper conductor stranded 1100 volt grade cable in & incl PVC Casing -n-caping /conduit of size not less than 20mm ISI marked ivory white with all accessories such as tee, bend, joint cover including anodized MS sunken boxes made out of MS sheet of thickness not less than 1.6 mm with earth dolly and PVC laminated hylem/Anchor ISI marked top cover 3.0 mm thick for mounting of switches/sockets/ regulator etc and PVC insulated & unsheathed 1100 volt grade copper conductor, stranded 1.5 sqmm. cable as continuous earth lead complete all as specified and colour coding of cables such as Phase - Red, Neutral – Black, and Earth – Green including taking down carefully copper/aluminum pt wiring (light fan, socket or power) complete including fittings such as switches, sockets, c/roses, lamp holders, tube light fittings, sketch fittings, wooden boards, bell push, call bell, MCBs, & regulators etc & making good to disturbed surfaces & matching with the existing colour of wall/floor :- .
For one light point or fan point controlled by one switch
For one Call Bell point controlled by one push button switch
For 5Amp independent socket point controlled by one switch
For one 3 pin ,5 Amp socket point with other switch on the same board
All as per Srlitem No.98 here in before but for power point wiring using with 2.5 sqmm PVC FR insulated ,unsheathed, copper conductor stranded 1100 volt grade cable and 2.5 sqmm PVC insulated ,unsheathed, copper conductor stranded 1100 volt grade cable as continuous earth wire
M&L for concealed point wiring with 1.5 Sqmm PVC-FR insulated, unsheathed, copper conductor, stranded 1100 volt grade cable in & incl PVC conduit, including modular metal flush boxes & modular white cover plate of suitable module with frame as per site requirement all fittings such as tees, bends, elbows, etc. all as per site requirements PVC insulated & unsheathed 1100 volt grade copper conductor, stranded 1.5 sqmm. cable as continuous earth lead complete all as specified and colour coding of cables such as Phase - Red, Neutral – Black, and Earth – Green including taking down carefully copper/aluminum pt wiring (light fan, socket or power) complete including fittings such as switches, sockets, c/roses, lamp holders, tube light fittings, sketch fittings, wooden boards, bell push, call bell, MCBs, & regulators etc & making good to disturbed surfaces & matching with the existing colour of wall/floor :-
For one light point or fan point controlled by one switch
For one Call Bell point controlled by one push button switch
For 5Amp independent socket point controlled by one switch
For one 3 pin ,5 Amp socket point with other switch on the same board
All as per Srl item No.101 here in before but for power point wiring using with 2.5 sqmm PVC FR insulated ,unsheathed, copper conductor stranded 1100 volt grade cable and 2.5 sqmm PVC insulated ,unsheathed, copper conductor stranded 1100 volt grade cable as continuous earth wire
S&F modular switch, one way,6 Amp 230, 1 module complete all as specified and directed .
S&F modular socket 6 Amp-2/3 pin combined 2 module complete all as specified and directed .
S&F modular switch, one way,6 A/16 Amp 230, 1 module complete all as specified and directed.
S&F modular socket 6 A/16-2/3 pin combined 2 module complete all as specified and directed .
S&F modular fan step regulator 120 Watt -2 module complete all as specified and directed.
S&F modular bell push 6A one module complete all as specified and directed .
S&F switch piano type flush, single pole, one way 5 A 230 V complete all as specified and directed.
S&F socket outlet, 5 pin, 5 Amp, flush type, 230 V complete all as specified and directed.
S&F switch piano type flush, single pole, one way 15 A 230 V complete all as specified and directed .
S&F socket outlet 2 in 1,6 pin, 5/15 A, flush piano type 240 V complete all as specified and directed.
S&F ceiling rose, surface backlite, three terminal complete all as specified and directed
S&F lamp holder insulated with back plate suitable for Angle/Batten fitting complete all as specified and directed.
S&F in repair/replacement bell ding dong 230 V, single phase complete all as specified and directed.
S&F electronic double space rotary 5 speed type regulator 120-280 V complete all as specified and directed .
S&F bell push flush type one way 5Amp 240 Volt complete all as specified and directed
S&F in repairs testing and commissioning of MCB SP 240 volt 6 Amp to 40 Amp 10 KA capacity having C-curve characteristics connected with suitable lugs complete all as specified and directed
S&F in repairs testing and commissioning of MCB SPN 240 volt 16 Amp to 40 Amp 10 KA capacity having C-curve characteristics connected with suitable lugs complete all as specified and directed
S&F in repairs sheet metal enclosure for DB double door, IP-43 when MCBs to be used SPN, 8 way, 240 V with 200 Amps rated bus bar complete all as specified and directed. Note :- Cutting and chasing in stone masonry and making good to disturbed surfaces shall be included in the quoted rate
S&F in repairs double door metallic sheet metal enclosure for DB double door(IP-42/43) When MCBs to be used SPN 4 ways, 240 V with 200Amps rated bus bar complete all as specified and directed. Note :- Cutting and chasing in stone masonry and making good to disturbed surfaces shall be included in the quoted rate
S&F in replacement TL fitting 20 watt for surface and wall mounted LED batten with ultra slim polycarbonate LED lighting fixture with high lumen output environmental friendly energy efficient complete all as specified and directed. Note :- Cutting and chasing in stone masonary and making good to disturbed surfaces shall be included in the quoted rate
S&F in repair/replacement socket outlet multi purpose, 3 pin, 15 Amp & 3 pin 5 amp, combination complete all as specified and directed. Note :- Cutting and chasing in stone masonary and making good to disturbed surfaces shall be included in the quoted rate
Pandey Construction and Engrs
v k builder
anil kumar sahu
M/S AJAY JAIN
HAFEEZ CONSTRUCTION
maharaja construction and suppliers
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .