Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹7.4 LAccepted-AOC 656 VINOBA BASTI SRI GANGANAGAR 335001 RAJ | SRI GANGANAGAR | SRI GANGANAGAR | RAJASTHAN | 335001 | ₹7.4 L | 1 | Accepted-AOC L1 |
| 2 | 2₹8.9 L+₹1.5 L (21.0%)Rejected-Finance | ₹8.9 L+₹1.5 L (21.0%) | 2 | Rejected-Finance Not Lowest |
| 3 | 3₹9.7 L+₹2.3 L (31.8%)Rejected-Finance HOUSE NO 40 CHOTTI BARADARI PART I GARHA ROAD NEAR MEDICAL COLLEGE JALANDHAR PB 144022 | JALANDHAR | JALANDHAR | PUNJAB | 144022 | ₹9.7 L+₹2.3 L (31.8%) | 3 | Rejected-Finance Not Lowest |
| 4 | 4₹9.9 L+₹2.5 L (33.8%)Rejected-Finance | ₹9.9 L+₹2.5 L (33.8%) | 4 | Rejected-Finance Not Lowest |
| 5 | 5₹10.0 L+₹2.6 L (35.0%)Rejected-Finance GROUND FLOOR TRACTOR MARKET KAITHAL ROAD ASSANDH KARNAL HARYANA 132039 | KARNAL | HARYANA | 132039 | ₹10.0 L+₹2.6 L (35.0%) | 5 | Rejected-Finance Not Lowest |
Tender Value
₹9.5 L
EMD Value
₹19,040
Closing Date
31 May 2021, 6:00 pmClosed
Garrison Engineer Abohar
Garrison Engineer Abohar Pin-152116
Provn of exhaust fans and ceiling fans against deficiency of Inf Bn-II and electric energy meter, DBs and allied works in Bldg No P-213 of KLP-II at Mil Stn Fazilka
2021_MES_439650_1
GE ABH-06/21-22
Open Tender
Civil Works
Item Rate
120 days
Fazilka Mil Stn
MES Registered Contractor enlisted in class E Category b (i) having deposited standing security of Rs 50000 with departments. Contractors not registered in MES should meet the MES enlistment criteria corresponding to appropriate class and category
5 documents required · 5 mandatory
₹500
Garrison Engineer Abohar
₹19,040
Yes
17 Jun 2021
1 May 2021
2 Jun 2021
1 May 2021
31 May 2021
17 May 2021
Amount
M & L point wiring complete with 1.5 Sqmm (nominal area) PVC FRLS insulated unsheathed copper stranded conductor cable with colour code in and including medium grade rigid PVC conduit with tees, bends, elbows, couplers, MS junction boxes concealed after cutting chases in wall, floor etc and making good to match with existing surface including sunken iron terminal box, 3mm thick bakelite sheet cover, clips, pipe hooks, brass screws, washers and 1.5 Sqmm single core stranded / solid copper conductor 1100 volts grade PVC insulated and unsheathed cable as earth continuity conductor to common earth and connecting to earth dolly for One light /bell point/ fan point controlled by one, one way switch all as specified and directed at site by Engineer – in – Charge.
All as per item No. here in before but for socket out let 3 pin 5 amp on same board all as specified and directed by Engineer - in - Charge
All as per item No. here in before but for socket out let 3 pin 5 amp on independent board all as specified and directed by Engineer - in - Charge
M & for point wiring complete with 2.5 Sqmm single core multi stranded copper conductor of 1100 volts grade PVC FRLS insulated and unsheathed cable for one multipurpose switch socket outlet 6 pin, 15 Amps on independent board including 1.5 Sqmm single core stranded / solid copper conductor 1100 volts grade PVC insulated and unsheathed cable as earth continuity conductor to common earth and connecting to earth dolly.
S & F ceiling rose 65 x 50mm three terminals PVC/ polycorbonate, isolated body all as specified and directed by Engineer - in - Charge .
S & F switch piano flush type single pole one way 5 Amp all as specified and directed by Engineer - in – Charge. Make : Anchor/Havells/Legrand
S & F piano type socket two in one, 3 pin 5 Amps 230 VAC supply Make : Anchor/Havells/Legrand
S & F switch piano flush type single pole one way 15 Amp all as specified and directed by Engineer - in – Charge.
S & F piano type socket two in one, 6 pin 5 Amps 230 VAC supply Make : Anchor/Havells/Legrand
Supply and fix microprocessor based single phase electronic temper proof energy meter of rating 10 to 60 Amps with optical communication port, conforming to IS:13779
S & F of Ceiling fan of 1200mm sweep monted in suitable arrangement for operation on 230 Volts, single phase, 50 cycle phase, 50 cycle per second, AC supply with electronic type regulator and connecting accessories BEE 5 Star rating and connecting up including three core PVC insulated PVC sheated copper conductor flexible cable from ceiling rose to fan fixing in ceiling complete and making the surface good after fixing the fan complete all as specified and directed. Make : BAJAJ/HAVELLS/ORIENT
S & F heavy duty exhaust fan of 450mm sweep mounted in suitable opening arrangement with louvers siitable for operation on 230 Volts, single pase, 50 cycle per second, AC supply and connecting up including three core PVC insulated PVC sheated copper conductor flexible cable 24/0.2mm deawn in flexible PVC conduit fixing in wall and making suitable hole for exhaust fan with necessary finishing of the surface good after fixing the fan complete all as specified and directed by Engr-In-Charge. Make : BAJAJ/HAVELLS/ORIENT
S & F isolator single pole 40 Amp 240 volt all as specified and directed by Engineer – in – Charge .
S & F of MCB suitable for 240 Volts AC supply, SPN with over load and short circuit protection and rupturing capacity not less than 10 KA and 16 to 32 Amps all as specified and directed.
S & F MCB distribution board of sheet metal single pole and neutral 8 way, single door, with 200 Amp rated bus bar 240 volt all as specified and directed by Engineer-in- Charge.
S & F sheet metal enclosure distribution board triple pole and neutral 4 way, double door, with 200 Amp rated bus bar 440 volt all as specified and directed by Engineer-in- Charge.
S & F sheet metal enclosure distribution board triple pole and neutral 4 way, double door, with 200 Amp rated bus bar 440 volt with incoming MCCB of rating 100 Amps all as specified and directed by Engineer-in- Charge.
S & F of MCB suitable for 415 Volts AC supply, TPN with over load and short circuit protection and rupturing capacity not less than 10 KA and 63 Amps all as specified and directed.
S & F of MCB suitable for 240 Volts AC supply, SP with over load and short circuit protection and rupturing capacity not less than 10 KA and 40 Amps all as specified and directed.
S & F of MCCB suitable for 415 Volts, 4 Pole, AC supply and short circuit protection and rupturing capacity not less than 16 KA and 100 Amps all as specified and directed.
S & F of MCCB 4 Pole 125 Amps suitable for 415 Volts AC supply, with over load and short circuit protection and repturing capacity not less than 10 KA all as specified and directed.
S & F of MCCB 4 Pole 63 Amps suitable for 415 Volts AC supply, with over load and short circuit protection and repturing capacity not less than 10 KA all as specified and directed.
Excavating in trenches, not exceeding 1.5m wide and not exceeding 1.5m in depth, for foundations or laying cables/ pipes etc and getting out in soft / loose soil all as specified and directed by Engineer - in - Charge.
Returning, filling in, including spreading, levelling, watering and well ramming in layers of soft / loose soil not exceeding 25cm thick all as specified and directed by Engineer - in - Charge.
Removal of excavated material to a distance not exceeding 50m and depositing where directed at a level not exceeding 1.5m above the starting point all as specified and directed by Engineer - in - Charge.
M & L sand cushioning for under ground cable 23 cm thick (one layer of 8 cm thickness before laying the cable and other layer of 15 cm thickness after laying the cable) all as specified and directed by Engineer-in-Charge.
Supply, laying, jointing and testing and commissioning 25 sqmm, 4 core XLPE insulated, screened, PVC bedded galanised steel strip or wire armoured electric power cable heavy duty multi stranded aluminium conductor and PVA sheathed LT cable 1100 Volts grade conforming to IS-7098 laid in trenches/ducts/fixed on poles/wall/laid under roads/paths/drain/culverts or passing through pipes complete all as specified and directed by Engr-In-Charge
S & F in repairs submain wiring with two single core cables PVC FRLS insulated unsheathed 6 Sqmm stranded copper conductor drawn in and including PVC conduit with and including PVC insulated 6.0 Sqmm stranded copper conductor cable as earth continuity conductor and connecting complete all as specified and directed by Engineer - in - Charge. Note : PVC cables two single core and one single core of sizes as mentioned will considered as one unit.
M & L as in repairs submain wiring with two single core cables PVC FRLS insulated unsheathed 4 Sqmm stranded copper conductor drawn in and including PVC conduit with and including PVC FRLS insulated 4.0 Sqmm stranded copper conductor cable as earth continuity conductor and connecting complete all as specified and directed by Engineer - in – Charge. Note : PVC cables two single core and one single core of sizes as mentioned will considered as one unit.
S & F submain wiring with four single core cables PVC FRLS insulated unsheathed 10 Sqmm stranded copper conductor drawn in and including PVC conduit with and including PVC FRLS insulated two single core cables 6.0 Sqmm stranded copper conductor cable as earth continuity conductor and connecting complete all as specified and directed by Engineer - in - Charge. Note : PVC cables two single core and one single core of sizes as mentioned will considered as one unit.
Excavating in trenches, not exceeding 1.5m wide and not exceeding 1.5m in depth, for foundations or laying cables/ pipes etc and getting out in soft / loose soil all as specified and directed by Engineer - in - Charge.
Returning, filling in, including spreading, levelling, watering and well ramming in layers of soft / loose soil not exceeding 25cm thick all as specified and directed by Engineer - in - Charge.
Removal of excavated material to a distance not exceeding 50m and depositing where directed at a level not exceeding 1.5m above the starting point all as specified and directed by Engineer - in - Charge.
M & L sand cushioning for under ground cable 23 cm thick (one layer of 8 cm thickness before laying the cable and other layer of 15 cm thickness after laying the cable) all as specified and directed by Engineer-in-Charge.
Labour for boring hole across the road/plinth/floor for cable passing without damaging the road/plinth/floor complete including necessary T&P all as specified and directed.
M & L brick protection using old size sub class ‘B’ bricks, laid flat, across the cable i.e. length perpendicular to the axis of cable all as specified and directed by Engineer-in-Charge.
Supply and fix GI pipe 40 mm bore light grade for protection of cable including provision of clamps, nuts, bolts etc required for fixing pipe along pole/wall/laid under the road/laid under the floor or in trenches complete all as specified and directed by Engr-In-Charge
Supplying and laying XLPE cable, PVC insulated, armoured, heavy duty multi stranded aluminium conductor, electric cable LT, 1100V grade of size 50 Sqmm 3.5 core complete all as specified and as directed by Engineer-in-charge.
PUNEET ENTERPRISES
UNITED ENGINEERING CORPORATION
N.R.Builders
swarn singh and co.
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .