Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹6.4 LAccepted-AOC GALI NO 1 VILLAGE BAGTHALA TEHSIL BAWAL DISTT REWARI 123501 | BAWAL | REWARI | HARYANA | 123501 | L1 | Accepted-AOC OK |
Tender Value
₹6.2 L
EMD Value
₹12,290
Closing Date
28 Mar 2022, 5:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
EE PD PWD B and R REWARI
GARHI BOLNI ROAD REWARI
Construction of Rooms over Litigents Hall in Judicial Complex at Rewari in Rewari Distt For Female Advocate RE-INVITED
2022_HRY_210304_1
CONST. OF ROOMS OVER LITIGENTS HALL REINVITED
Open Tender
Civil Works - Buildings
Works
92 days
REWARI
Please refer Tender documents.
3 documents required · 3 mandatory
₹1,000
₹12,290
Yes
REWARI
10 Jun 2022
7 Mar 2022
29 Mar 2022
7 Mar 2022
28 Mar 2022
7 Mar 2022
11 Mar 2022
120 days
Amount
Dismantling doors, windows and clerestory windows (steel or wood) shutter including chowkhats, architrave, holdfasts etc. complete and stacking within 50 metres lead: Of area beyond 3 sq. metres [HSR 5.29.2]
Demolishing R.C.C. work manually/ by mechanical means including stacking of steel bars and disposal of unserviceable material within 50 metres lead as per direction of Engineer - incharge. [HSR 5.25]
Dismantling tile work in floors and roofs laid in cement mortar including stacking material within 50 metres lead. For thickness of tiles above 25 mm and up to 40 mm [HSR 5.43.2]
Demolishing mud phaska in terracing and disposal of material within 50 metres lead. [HSR 5.11]
Disposal of building rubbish / malba / similar unserviceable, dismantled or waste materials by mechanical means, including loading, transporting, unloading to approved municipal dumping ground or as approved by Engineer-in-charge, beyond 50 m initial lead, for all leads including all lifts involved. [HSR 5.70]
Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor four level, excluding cost of centering, shuttering, finishing and reinforcement : 1:1.5:3 (1 cement : 1.5 coarse sand(zone-111) : 3 cum graded stone aggregate 20 mm nominal size) [HSR 6.15.1]
Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor four level, excluding the cost of centering, shuttering, finishing and reinforcement with 1: 1.5:3 (1 cement : 1.5 coarse sand(zone-111) : 3 graded stone aggregate 20 mm nominal size). [HSR 6.16]
Steel reinforcement for R.C.C. work, where not included in the complete rate of RCC, including straightening, cutting, bending, placing in position, binding, wastage, overlaps, welded joints, spacer bars, chairs, stays, hangers and annealed steel wire etc. complete in all respect below plinth level Note:- Reinforcement shall be measured in length including hooks, if any, separately for different diameters as actually used in work , excluding overlaps. Wastage, overlaps, couplings, welded joints, spacer bars, chairs, stays, hangers and annealed steel wire or other methods of binding & placing shall not be measured and cost of these items shall be deemed to be included in the rates for reinforcement. Thermo-Mechanically Treated bars of grade Fe-500D or more. [HSR 6.33.6]
Centering and shuttering including strutting, propping etc. and removal of form for Walls (any thickness) including attached pilasters, buttresses, plinth and string courses etc. [HSR 6.30.2]
Centering and shuttering including strutting, propping etc. and removal of form Suspended floors, roofs, landings, balconies [HSR 6.30.3]
Centering and shuttering including strutting, propping etc. and removal of form Lintels, beams, plinth beams, girders, bressumers and cantilevers [HSR 6.30.5]
Centering and shuttering including strutting, propping etc. and removal of form Columns, Pillars, Piers, Abutments, Posts and Struts [HSR 6.30.6]
Brick work with common burnt clay non-modular bricks of class designation 7 .5 in superstructure above plinth level up to floor IV level in all shapes and sizes in : Cement mortar 1:6 (1 cement: 6 coarse sand) [HSR 7.22.2]
Half brick masonry with common burnt clay non-modular bricks of class designation 7 .5 in superstructure above plinth level up to floor IV level. Cement mortar 1 :4 ( 1 cement :4 coarse sand) [HSR 7.28.2]
Supply & fixing Windows frames (Chowkhats) including mullions consisting frame fabricated from sheet roll formed out of 1.2mm thick galvanized sheet as per IS:277 (Base steel as per IS 513) with zinc of 120 gm/sqm & Powder coated with pure Polyester powder up to 50 microns (as per approved colour), 3 Nos. 100mm butt - hinges 2mm thick, 6 Nos. 1.2mm thick CRCA electroplated stiffner, 6 Nos. M.S hold fast with split and tail welded to stiffner plate 200mm long, receiver for aldrop, weld less corner assembly with brackets & screws, M.S tie rod 50mm x 25mm to be fixed at bottom finished with powder coated total thickness of coating 0.6mm of approved shade, fixed in position including the cost of cement concrete for 1 :2:4 for fixing lugs complete in all respects as per drawing, design, specification & entire satisfaction of Engineer-in-charge. Door Frame of size 125mm x 60mm with 37mm wide double metre rebate for 35mm door shutter [HSR 13.21.2]
Supply & fixing Windows frames (Chowkhats) including mullions consisting frame fabricated from sheet roll formed, total sheet thickness with coating 0. 72mm for outer frame & 0.58 mm. for other sections.galvanized sheet (Base steel as per IS 513) with zinc of 120 gm/Sqm as per IS 277 steel sheet pre coated (as per approved colour) with Polyster paint of 12-16 micrones thickness under coat of EPOXY primer & back coat with ALKYD backerof 5-7 micrones, weldless comer ssembly with brackets & screws, fixed in position by means of PVC & metal hold fastner with PVC cap complete in all respects as per drawing, design, specification & entire satisfaction of Engineer-incharge. Windows Outer frame of size 98mm x 50mm and central mullion 46mm x 70mm and Additional Mullion 29mm x 46mm with Double rebate [HSR 13.25.1]
Providing and fixing glazed shutters for doors, windows and clerestory windows using 4 mm thick float glass panes, including ISi marked M.S. pressed butt hinges bright finished of required size with necessary screws Kiln seasoned and chemically treated Hollock wood 35 mm thick [HSR 12.10.2.1]
Providing and fixing wire gauge shutters using galvanized M.S. wire gauge of average width of aperture 1.4 mm in both directions with wire of dia 0.63 mm, for doors, windows and clerestory windows with hinges and necessary screws: Kiln seasoned and chemically treated Hollock wood [HSR 12.19.1.1.2]
Providing and fixing ISi marked flush door shutters conforming to IS : 2202 (Part I) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters: 35 mm thick including ISi marked Stainless Steel butt hinges with necessary screws [HSR 12.37.1]
Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by welding [HSR 12.50.1]
Providing & fixing glass panes with putty and glazing clips in steel doors, windows, clerestory windows, all complete with 5.5 mm thick glass panes [HSR 13.10.2]
Providing and fixing aluminium e xtruded section body tubular type universal hydraulic door closer (having brand logo with ISi, IS: 3564, embossed on the body, door weight up to 3 6 kg to 80 kg and door width from 701 mm to 1 000 mm), with double speed adjustment with necessary accessories and screws etc. complete. [HSR 12.89]
Providing and fixing aluminium sliding door bolts, ISi marked anodised (anodic coating not less than grade AC 10 as per IS : 1868), transparent or dyed to required colour or shade, with nuts and screws etc. complete : 300x16 mm [HSR 12.98.1]
Providing and fixing aluminium tower bolts, ISi marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete 300x10 mm [HSR 12.99.1]
Providing and fixing aluminium tower bolts, ISi marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete For windows (150x10 mm) [HSR 12.99.4]]
Providing and fixing aluminium handles, ISi marked, anodised (anodic coating not less than grade AC 1 O as per IS : 1868) transparent or dyed to required colour or shade, with necessary screws etc. complete 125 mm [HSR 12.102.1] For Doors
Providing and fixing aluminium handles, ISi marked, anodised (anodic coating not less than grade AC 1 O as per IS : 1868) transparent or dyed to required colour or shade, with necessary screws etc. complete For Window 100 mm [HSR 12.102.2]
Providing and fixing aluminium hanging floor door stopper, ISi marked, anodised (anodic coating not less than grade AC 1 O as per IS : 1868) transparent or dyed to required colour and shade, with necessary screws etc. complete. Twin rubber stopper [HSR 12.103.2]
Smooth finishing of the exposed surface of R.C.C. work with 10 mm thick cement mortar 1 :4 (1 Cement : 4 fine sand). [HSR 11.51]
12 mm cement plaster of mix 1 :6 (1 cement: 6 fine sand) [HSR 11.5.4]
15 mm cement plaster on the rough side of single or half brick wall of mix : 1 :6 (1 cement: 6 fine sand) [HSR 11.6.2]
Providing and laying of base course of floors consisting of 100 mm thick cement 1 :8: 16 and 100 mm sand or stone filling. [HSR 10.1]
Providing and laying of conglomerate floor 40mm thick cement concrete topping 1 :2:4 [HSR 10.8]
Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1 :4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc., complete. Size of Tile 600x600 mm [HSR 10.63.2]
Providing and laying Vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1 :3 (1 cement: 3 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joint with white cement & matching pigments etc. complete Size of Tile 600x600 mm [HSR 10.67.2].
Providing and applying two coats white cement based putty of approved brand and manufacturer, over plastered surface and grinding the surface smooth with sand paper to get en even and smooth finish including cost and carriage of all material , labour charges, scaffolding, sundries etc. complete (HSR 11.58)
Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade: New work (two or more coats) over and including water thinnable priming coat with cement primer (HSR 11.64.1)
Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface: Water thinnable cement primer (HSR 11.67.1)
Finishing walls with Acrylic Smooth exterior paint of required shade : New work (Two or more coat applied @ 1.67 litre/1 O sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm) (HSR 11.95.1)
Preparation of ply wood surface for painting including sand papering the surface and applying filling with approved quality filler consisting of white lead, linseed oil, varnish and chalk mitti including finishing the surface to required finish complete. (HSR 11.76)
Applying pink primer or aluminium priming coat on wood work including preparation of surface, Knotting and stopping etc. (HSR 11.77)
Painting two coats excluding priming coat with synthetic enamel paint in all shades on new wood work or metallic or plastered or concrete surfaces to give an even shade. (HSR 11.78)
Painting top of roofs with bitumen of approved quality @ 17kg per 1 O sqm impregnated with a coat of coarse sand at 60 cudm per 10 sqm, including cleaning the slab surface with brushes and finally with a piece of cloth lightly soaked in kerosene oil complete With residual type petroleum bitumen of grade VG -10 (HSR 9.10.1)
10 cm thick (average) mud phaska of damped brick earth on roofs laid to slope consolidated and plastered with 25 mm thick mud mortar mixed with bhusa @ 35 kg per cum of earth and gobri leaping with mix 1: 1 (1 clay : 1cow dung) and covered with flat tile bricks, grouted with cement mortar 1: 3 (1 cement: 3 fine sand) mixed with 2% of integral water proofing compound by weight of cement and finished neat: With common burnt clay non-modular brick tile of class designation 10 (HSR 9.11.1)
Providing gola 75x75 mm in cement concrete 1: 2:4 (1 cement : 2 coarse sand : 4 stone aggregate 10 mm and down gauge), including finishing with cement mortar 1 :3 (1 cement : 3 fine sand) as per standard design : In 75x75 mm deep chase (HSR 9.17.1)
Making khurras 45x45 cm with average minimum thickness of 5 cm cement concrete 1 :2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate of 20 mm nominal size) over P.V.C. sheet 1 m x1 m x 400 micron, finished with 12 mm cement plaster 1 :3 (1 cement : 3 coarse sand) and a coat of neat cement, rounding the edges and making and finishing the outlet complete. (HSR 9.18)
Providing and fixing on wall face Unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes. 110 mm diameter (HSR 9.57.2)
Providing and fixing on wall face Unplasticised - PVC moulded fittings/accessories for Unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion. Bend 87.5°. 110 mm bend (HSR 9.58.5.2) Note:- 1. In case of any difference in the unit & nomenclature of any of the HSR Items of Civil, P.H., depicted in this DNIT and that given in HSR, the unit and nomenclature given in HSR shall be applicable. 2. Only reputed make material will be used (make/brand exhibited in HSR and exhibited in approved standard document) as approved by Engineer-in-charge, while executing various items/works at site.
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .