Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹7.9 LAccepted-AOC 74 BENTINCK STREET GROUND FLOOR KOLKATA 700 001 | KOLKATA | KOLKATA | WEST BENGAL | 700001 | L1 | Accepted-AOC LOWEST | |
| 2 | L2₹9.0 L+₹1.1 L (14.5%)Rejected-Finance 1363 NASKARHAT MADHYAPARA KOLKATA 700039 | KOLKATA | KOLKATA | WEST BENGAL | 700039 | L2 | Rejected-Finance HIGHEST | |
| 3 | L3₹19.1 L+₹11.2 L (142.8%)Rejected-Finance 109 5A HAZRA ROAD KOLKATA 700026 | KOLKATA | KOLKATA | WEST BENGAL | 700026 | L3 | Rejected-Finance HIGHEST |
Tender Value
Refer Docs
EMD Value
₹20,200
Closing Date
31 Aug 2021, 2:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Superintending Engineer PWD Electrical
Superintending Engineer PWD North Bengal Electrical Circle P.W.D Inspection Bungalow Annex Building 1ST Floor Kutchery Road Venus More Siliguri
S.I.T.C of Fire Alarm and Detection System at Virus Research and Diagnostic Lab VRDL under Micro Biology Department of North Bengal Medical College and Hospital Siliguri
2021_WBPWD_338994_1
WBPWD/SENBEC/NIT-23/2021-2022
Open Tender
ELECTRICAL WORKS ORG
Item Rate
10 days
N.B.M.CandH Sushrutanagar Siliguri
Please refer Tender documents.
4 documents required · 4 mandatory
₹20,200
6 Nov 2024
5 Aug 2021
2 Sept 2021
5 Aug 2021
31 Aug 2021
10 Aug 2021
120 days
Amount
Eleectrical Installation Work
SITC of Fire adressable fire alam system
Supply, installation, Testing and commissioning of VDS approved Microprocessor based intelligent, addressable 2 loops fire alarm control panel expendable upto 4 loop VDS approved fully networkable .The FACP shall have minimum 640 character Display with fully functional QWERTY Keypad, TFT multicolordisplay.each loop capable of taking maximum loading of 125 detectors and 125 devices in one loop with 20% spare capacity, in any combination. The panel shall be soft addressable type. The panel shall be able to give pinpoint location of all fire/fault conditions. Further, the panel must be able to automatically switch off respective control switches whenever any alarm is triggered. The panel should be able to store sufficient numbers of log events in this memory as per recommended standards.
The panel shall have in built rectifier. . Internal battery charger complete as required. The FACP shall be capable of being networked with other similar FACP located at different part of the premises through single RS 485 bus. (Approved Make: SIEMENS / SECURITON / EDWARD / AUTRONICA / ESSAR)
Supply, Installation, Testing & Commissioning of Analog Addressable Intelligent multi-sensor detector, VDS approved with inbuilt optical smoke sensors as well as additional heat detector sensor with decentralized intelligence, soft addressable photothermal type with inbuilt fault Isolator as per NFPA style 7 wiring complete with base having IP as per recommended Standard.with MS Powder coated Junction Box for mouting on Surface / on False Ceiling / Below False Floor, Cable lugs at Ends, cable compression glands, cable tags and Ferruling(Approved Make: SIEMENS/SECURITON/EDWARD/AUTRONICA/ESSAR)
Supply, Installation, Testing & Commissioning of Addressable Manual Call Point VDS approved soft addressable type within built fault isolator as per NFPA style 7 wiring complete as required. (Approved Make: SIEMENS / SECURITON / EDWARD / AUTRONICA / ESSAR)
Supply, Installation, Testing & Commissioning of Addressable Loop Powered Hooter (sound output of minimum 90 db) with inbuilt isolator & IP65 base and VDS approved. (Approved Make: SIEMENS FDS- 229-R / SECURITON / EDWARD / AUTRONICA / ESSAR)
Supply, Installation, Testing & Commissioning of Addressable Relay Module/ output module with Switch and all mounting accessories complete as required.VDS approved soft addressable type within built fault isolator as per NFPA style 7 wiring complete as required .(Approved Make: SIEMENS /SECURITON /EDWARD/ AUTRONICA /ESSAR) Shall be complete with Pilot Relay for Tripping of Third Party Equipment, suitable for switching 5A/15A current through the Relay contacts , MS Powder coated Junction Box for mouting on Surface, Cable lugs at Ends, cable compression glands, cable tags and Ferruling
Supply, Installation, Testing & Commissioning of Response Indicator, with all other accessories. (Approval standards:VdS, EN54; Approved Make: Honeywell / Securitron / Secuton / Siemens)
Supply & Laying of 2 Core 1.5 sqmm FRLS Shilded copper cable twisted (For Loop) with 20 mm EI rigid conduit pipe (Red Colour to identify Fire line) on the surface of the wall (Approved Make: FOR CABLE: POLYCAB /RR /FINOLEX/KEI;
Supply and fixing of 230V, 1 KVA Off Line UPS. (Make NUMERIC / APC)
SITC of Self Iluminated, 230 VAC Power Operated with 24 VDC Battery Back Up Exit Signage. (Make: Eaton / NoToFire / Schrack / AutoGlow / Prolite)
GLYPTIC
M/s Security Engineers Private Limited
technical_647505.pdf
PDF • 0.07 MB
techsummary_647505.pdf
PDF • 0.22 MB
finance_647505.pdf
PDF • 0.07 MB
BOQ Comparative Chart
xlsx • 0.01 MB
finsummary_647505.pdf
PDF • 0.09 MB
23AOC21-22.pdf
PDF • 1.45 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .