Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹4.7 LAccepted-AOC R O IQBAL MARKET AALI MAJID EIDGAH SRINAGAR KASHMIR | SRINAGAR | JAMMU AND KASHMIR | 190001 | L1 | Accepted-AOC Accepted Being L1 | |
| 2 | L2₹6.5 L+₹1.8 L (38.3%)Rejected-Finance | L2 | Rejected-Finance Other Than L1 | |
| 3 | L3₹7.0 L+₹2.3 L (49.8%)Rejected-Finance | L3 | Rejected-Finance Other Than L1 | |
| 4 | Rejected-Technical | - | Rejected-Technical Copy of EPF code number/allotment letter Has not been uploaded/Submitted |
Tender Value
₹10 L
EMD Value
₹20,000
Closing Date
3 Jun 2022, 6:00 pmClosed
AGE (I) CIF (K)
AGE (I) CIF (K) SHALATENG
REPAIR/MAINTENANCE OF LIGHTENING CONDUCTOR, DISTRIBUTION BOXES WITH MCCB, LED DISPLAY, FLOOD/SECURETY LIGHTS AND OTHER LUMINARIES ALONG WITH SERVICE CABLE ETC OF ATC BLDG AND HANGERS OF 663 OF R AND O AT SHALATENG GARRISON UNDER AGE (I) CIF (K).
2022_MES_522314_1
CA NO. AGE (I) CIF (K) - 18/2022-23
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
SHALATENG
AS PER NIT AND TENDER DOCUMENTS
9 documents required · 9 mandatory
₹500
AGE (I) CIF (K)
₹20,000
Yes
14 Jun 2022
6 May 2022
6 Jun 2022
6 May 2022
3 Jun 2022
20 May 2022
Amount
Taking down carefully copper/aluminium point wiring (light, fan, light & power socket) complete with fittings and fixtures such as switches,ceiling rose ,pendents ,regulators,socket,lamp holders brackets,bulk head fitting, etc removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and also making good distrubed surfaces of wall,floors etc, complete all as specified and directed by the Engineer-in-Charge.
Point wiring with 1.5 sqmm copper conductor (Multistranded) PVC insulated and unsheatheted FRLS electric cable 1100 volts grade and including PVC casing caping/conduit pipe of suitable size with all fittings accessories and including PVC insulated electric cable 1100 volts, 1.5 sqmm (multi stranded) copper conductor single core (Green colour) cable as continious earth wire connected to common earth dolly including sunk sheet terminal box made out of 1.6 mm thick MS sheet concealed on wall or on surface as per site requirement and making good distrubed surface of wall ,covered with 3 mm thick plastic laminated for one light /fan/bell point controlled by one No, one way 5 Amps switch, complete all as specified and as directed by the Engineer-in-Charge.
Piano type switch one way, SP, flush type, 5 Amps, 230 volts AC, 50 Hz, complete all as specified and as directed by the Engineer-in-Charge.
Replacement of existing Sheet metal enclosure DB with new Sheet metal enclosure factory made (double door) shutter type for MCB DB TPN horizental type, 440 Volts, 4 ways with 200 Amps rated bus bar, neutral link, earth bar, complete all as specified and as directed by the Engineer-in-Charge.
Replacement of existing Sheet metal enclosure DB with new Sheet metal enclosure factory made (double door) shutter type for MCB DB SPN, 240 Volts, 12 ways with 200 Amps rated bus bar, neutral link, earth bar, complete all as specified and as directed by the Engineer-in-Charge.
Replacement of existing Sheet metal enclosure DB with new Sheet metal enclosure factory made (double door) shutter type for MCB DB SPN, 240 Volts, 8 ways with 200 Amps rated bus bar, neutral link, earth bar, complete all as specified and as directed by the Engineer-in-Charge.
MCB SPN, 40-63 Amps, 230 volts, 10 kA rupturing capacity, 'C' curve type, including taking down old existing, complete all as specified and as directed by the Engineer-in-Charge.
MCB SP, 5 -32 Amps, 230 volts, 10 kA rupturing capacity, 'C' curve type, including taking down old existing, complete all as specified and as directed by the Engineer-in-Charge.
Edgepro round slim-fit low profile downlights are engineered to deliver superior light output and uniformity utilising the latest edge-lit LED technology.An ideal solution where ceiling voids are limited but high lumen output 12 Watt LED and making of electrical connection with and including three core flexible copper conductor cable of suitable size, including taking down existing old unserviceable, complete all as specified and as directed by the Engineer-in-Charge. Make :- Havells Cat No- EDGEPRORDDLR12WLED857S or equivalent in Bajaj/Crompton Greaves/Phillips
42 Watt LED Light fitting 2ft x 2ft recess mounting ceiling light fitting flush to ceiling Aura I pairs super bright LED's with highly efficient light-smoothing optics to deliver superior illumination and energy savings year after year with LED tube light and making of electrical connection with and including three core flexible copper conductor cable of suitable size, including taking down existing old unserviceable, complete all as specified and as directed by the Engineer-in-Charge. Make : Havells Cat part No VENUSNEOHE2X2PLR18-42WLED830MOD or equivalent in /Bajaj/Philips/Wipro
LED light fitting RADIOSO HIGH BAY energy saving, environment friendly & robost open highbay LED luminaire with high efficacy suitable for ceiling (surface/suspended) 150 watt, and making of electrical connection with and including three core flexible copper conductor cable of suitable size, including taking down existing old unserviceable complete all as specified and as directed by the Engineer-in-Charge. Make:Havells cat part No - RADIOSOHB150WLED7576DBOPC. or equivalent in Bajaj/Phillips
LED light fitting SAUCER energy saving, environment friendly & robost highbay/mediumbay LED IP65 luminaries with high efficiency, 150 watt, and making of electrical connection with and including three core flexible copper conductor cable of suitable size, including taking down existing old unserviceablecomplete all as specified and as directed by the Engineer-in-Charge. Make:-Havells cat part No - SAUCERPLUSHBP150WLED85790DTOLTG or equivalent in Bajaj/Phillips
Replacement of submain wiring with PVC insulated unsheathed copper conductor cable, multi stranded, single core, FRLS type, 1100 volts grade 2 x 6 sqmm complete drawn in and including casing caping/PVC conduit ISI marked of suitable size and its accessories along with 1x 6 sqmm PVC insulated unsheathed copper conductor cable, multi stranded for continuous earth wire including making good the disturbed surface, complete all as specified and directed by the Engineer- in-Charge. Note :- 2 +1 run of 6Sqmm cable including casing caping/PVC conduit of suitable size shall be measured as one running metre.
Air termination lightening conductor single pointed copper rod 12mm dia and 300mm long fixed properly on top of the Hangers/ATC building, complete all as specified and directed by the Engineer-in-Charge.
Test point terminal clock made out of gun metal or phosphorus bronze size 75x75x25 mm drilled and screwed including 3 Nos 8mm dia 25mm long hexa head screw, complete all as specified and as directed by Engineer-in-Charge.
Copper strrip of size 20mm x 3.15mm thick with and including saddles and fixing screws etc for roof conductor or down conductor above ground , complete all as specified and as directed by Engineer-in-Charge.
Earthing complete with galvanized steel earth plate electrode 600 mm x 600 mm x 6.30 mm thick buried directly in ground vertically in a pit of depth not less than 2.25 metre below ground levels with top edge of the earth plate not less than 1.50 metre below normal ground level surrounded from all sides by mixture of charcoal and common salt and electrode connected to and including copper strip, 20x5 mm as earthing lead by means of bolts, nuts check nuts and washers of galvanised steel, 25 mm bore (light grade) GI pipe for protection of earthing lead and GI pipe light grade 20 mm dia bore for watering funnel with wire mesh including provision of concrete pit in plain cement concrete 1:2:4, type B-1 using 20mm graded crushed stone aggregate with 40 mm thick cover of reinforced cement concrete 1:2:4, type B-I, using 20 mm graded crushed stone aggregate, reinforced with XPM weight not less than 4 Kg /Sqm and frame of angle iron 25 x 25 x 6mm with lugs 02 Nos and with 6mm dia MS bar handle made to shape ,excavation and earth work in any type of soil, returning filling in and removal of surplus soil including testing including testing on completion, complete all as specified and and shown in electrical plate No 3 of MES Schedule 2009 Part-I, complete all as specified and as directed by the Engineer-in-Charge. Note:- Earthing to be done for replacement of existing earthing. The materials retrieved from earthing shall be credited to contractor.
Galvanized iron tubing 40mm bore light grade with all fittings,laid in trenches or under road crossing , or fixed alongwith poles/walls with clamps made of mild steel flat iron 25mm x 3mm including GI nuts, bolts and washers as protection pipe for cables including taking out down/out old existing pipe, complete all as specified and directed by Engineer- in-Charge.
Note :- An amount of Rs.11,520.00 on account of credit schdule for Sch 'A' Part-II Shall be deducted from the total amount of BOQ to arrive at the contract sum.
JK BUILDERS AND ENGINEERS
M/S YATTOO CONTRACTORS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .