Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹11.4 LAccepted-AOC 15 GURU RAM DASS COLONY MITHAPUR JALANDHAR | L1 | Accepted-AOC Lowest bid | |
| 2 | L2₹12.0 L+₹62,562.80 (5.50%)Rejected-Finance | L2 | Rejected-Finance Other than lowest bid | |
| 3 | L3₹12.2 L+₹77,609 (6.82%)Rejected-Finance | L3 | Rejected-Finance Other than lowest bid |
Tender Value
₹15 L
EMD Value
₹30,000
Closing Date
20 Jun 2020, 6:00 pmClosed
CWE Jalandhar Cantt
HQ CWE kabir Road Jalandhar Cantt Pin-144005
Please refer tender documents
2020_MES_334725_1
CA NO CWE/JAL/W-81/2019-20 8319/81/E8
Open Tender
Civil Works
Item Rate
180 days
Jalandhar Cantt
Class E Category a(i) for contractors enlisted with MES
8 documents required · 8 mandatory
₹500
Garrison Engineer West JRC
₹30,000
Yes
16 Jul 2020
17 Mar 2020
22 Jun 2020
17 Mar 2020
20 Jun 2020
30 May 2020
Amount
Dismantling of brick tiles single layer as in roof covering complete all as specified.
Demolition of mud in roofs any thickness incl plastering and leeping (whether full thickness removed or only a part thereof) complete all as spcified..
Roughening surfaces of old concrete floor/wall by picking, sweeping clean and washing down with water to remove dust etc .and brushing neat cement slurry with 3 kg of cement per sqm, complete all as specified and directed.
M&L for providing PCC type B-1, (1:2:4) using 20mm graded stone aggregate as in roof padding concrete to bring the extg slab in slope of 1:40, complete all as specified and directed.
M&L for applying evenly a tack coat of industrial bitumen 85/25 at the rate of 1.2kg per sqm including cleaning surfaces over land including bitumen primer @ 0.3 kg/sqm complete all as specified.
Material & labour for APP based polymeric membrane minimum weighing 3kg/sqm and minimum 3mm thick reinforced with polyster non woven fabric (wt. not less than 150 gms/sqm) and with properties of high penetration and centre core consisting of 90 micron high molecular high density polyethylene film consisting of five layers laid with torching application to the surface complete and sealing the side as well as end laps with torch (overlap should not be less than 10cm) complete all as specified and directed.
Material & labour for 40mm thick brick tiles laid over and including 15mm thick screed bed in cement mortar (1:6) mixed with 5% of crude oil by weight of cement complete all as specified and directed.
All as per item No. 7 above but except tiles complete all as specified and directed.
M&L for flush pointing to brick roof tiles in cement mortar 1:3 all as specified
Taking up asbestos cement pressure pipes including all fitting 100mm bore complete all as specified and directed.
S&F 110 mm dia PVC (SWR ) pipes 1st quality single socketed in any length with rubber rings joits fixed to walls complete all as specified and as directed.
S&F 110 mm dia PVC (SWR ) bends any radius complete all as specified and as directed.
Taking down cement plaster on brick work or concrete surfaces including racking out joints hacking for key, scrubbing down with water etc. and removing rubbish complete all as specified and directed.
M&L Rendering 15mm thick in Cement Mortar 1:6 on fair faces of brick walls or on Concrete Surfaces, finished even and smooth,without using extra cement, complete all as specified and as directed.
M&L Rendering 15mm thick in Cement Mortar 1:4 on fair faces of brick walls or on Concrete Surfaces, finished even and smooth,without using extra cement, complete all as specified and as directed.
M&L plastering 5 mm thick in cement mortar (1:3) furnished even & smooth without using extra cement as on ceiling, complete all as specified and directed.
M&L for prepration of newly surfaces of wall and applying two coats of cement base paint over a coat of cement primer, complete all as specified and directed.
M&L for prepration of newly surfaces of wall and applying three coat of white wash on ceiling, complete all as specified and directed.
M&L for prepration of old plastered/treated surface of ceiling and applying two coats of white wash on ceiling, complete all as specified and directed.
M & L for preparation of newly plastered surfaces of walls and apply three coats of white wash complete all as specified and directed.
M & L for machine cut kota stone slab 18 to 20 mm thick as in flooring / stair case landing, laid over & incl. 20mm thick cement screed base in CM 1:4 and jointed with grey cement slurry mixed with pigment to match the shade of slab including rubbing and polishing, complete all as specified and directed.
M & L for machine cut kota stone slab 18 to 20mm thick as in skirting/steps of stair case laid over & incl.10mm thick cement screed base in CM 1:4 and jointed with grey cement slurry mixed with pigment to match the shade of slab including rubbing and polishing, complete all as specified and directed.
M&L for Non - skid Ceramic coloured tiles 7 to 8 mm thick (square/rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, in floors etc. set and jointed inneat cement slurry and pointed in white or coloured cement to match over and incl 15mm thick bedding layer in cement mortar 1:6, complete all as specified and directed.
All as per item no. 23 here in before but on vertical surfaces such as dado, skirting etc over and including 10mm thick cement plaster finished even and rough to receive tiles in CM 1:4 complete all as specified and directed.
Taking down chowkhats or frame with shutter w/o taking off shutter from the frame area not exc 1.5 Sqm each all as specified.
Supply & fix Steel windows 1.25 mm thick Box type (primer coated) ERW hollow ‘P’ section of size 60mm x 25mm single rebated comprises of glazed skeleton shutter ERW Sec 50mmx20mm and 1mm thick with one or two openable leaf consisting two Nos sash bar of ‘T’ section 20mm x 3mm complete welded to frame with one vertical mullion of ERW box type ‘T’ section of size 60mmx25mm and 1.25mm thick including cuttings holes and making good dismantled portion in PCC (1:3:6) type C1 using 20mm graded stone aggregate. Four Nos for each window including following fittings welded to framed shutter :- (a) Mild steel holdfasts 150mm long 12mmx3mm made to shape per window -04 Nos, (b) Handle of Z Sec 20mmx25mm, 100mm long per leaf-01 No, (c) Stopper per leaf -01 Nos, (d) Cleat 55 mm long of hollow square 15mmx20mmx63mm welded to hinges per leaf -01 No, (e) MS pintle hinges of size 75mmx75mmx12mm per leaf -02 Nos, complete all as specified in drawing No CEJZ/TD/1019, Sh 1/3 to 3/3 and No. CEJZ/TD/1020, Sh 1/3 to 3/3. Note : For item Ser Nos 26 & 27 (i) fabrication shall be as per drawing No CEJZ/TD/1019, Sh 1/3 to 3/3 and No. CEJZ/TD/1020, Sh 1/3 to 3/3 can be seen at HQ CWE JRC during any working days. (ii) Glass wire gauge painting & grills shall be measured and paid separately.
All as per item No. 26 above but window with gauzed shutter complete all as specified and directed.
Material & labour for framed work such as grills, gratings, etc.. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work con- forming to Fe.290.Gde-E-165 complete all as specified and directed.
Taking down shutter area exc 1.00 sqm but not exc 2 sqm complete all as specified.
Taking down chowkhats or frame with shutter w/o taking off shutter from the frame area exc 1.5 Sqm but n-exc 4 sqm each .
Supply and fix structural steel framed work as in doors frames, cooler stand or other section with gusset plates, rails, braces, etc. using steel conforming to Fe-410-W (Gde-E-250) quality-A complete including drilled for fixing of steel sheeting or other covering; doors, door frames, chowkhats etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing including necessary cutting drilling and welding etc complete all as specified and directed.
Supply and fix mild steel plain black sheet 1 mm thick as in wall cladding, steel gates and similar work, cut to size, holes punched including round headed screws, clout nails or rivets and fixed to wood or steel framing with plain 40 mm lap joints with riveted or welded seams, including bendingor turning up, mitred angles, etc complete all as specified and directed.
S&F 35 mm thick IInd class hard wood plain framed factory made paneled shutters with panel of 9 mm BWP commercial veneering on both veneered particle board with commercial veneering on both faces. The size of rail and stile as per IS :1003 (part-I) kiln seasoned and chemically treated complete all as specified.
S&F 35 mm thick IInd class hard wood glazed or skelton shutter factory made open rebated prepared to receive glass, gauge etc.without sash bars edges of framing plain fitted with cut & mitred beads for securing glass etc size of member all as per clause 8.23 (a) of SSR part-I
S&F 100 mm size butt hinges medium weight cold rolled mild steel, complete all as specified and directed.
S&F 300mm long mild steel barrel tower bolt, ISI marked stove enamelled black with bright bolt and fixed complete all as specified and directed.
S&F 150mm size mild steel pressed handles oval type ,stove enameled black, complete all as specified and directed.
S&F 300mm long mild steel sliding door bolts ISI marked clip & bolt type, stove enamelled black,with bright bolt not less than 16 mm dia with and including minimum of 6 bolts and nuts,four on bolt plate and two on staple plate complete all as specified.
Supply and fix galvanised mild steel wire cloth 0.56mm nominal dia of wire and average width of aperture 1.18 mm and fixed with tinned tacks or galvanized wire staples complete all as specified and directed.
Supply and fix 3 mm thick sheet glass ordinary quality and glazing with oil putty in squares not exceeding 0.50 Sqm in each pane complete all as specified and directed.
M&L for preparation of new wood surface of any description over 10 cm width or grith and applying two coats of synthetic enamel paint over a coat of pink primer, complete all as specified and directed.
M&L for preparation of new steel surface of any description over 10 cm width or grith and applying two coats of synthetic enamel paint over a coat of red oxide, zinc chrome, complete all as specified and directed.
M&L for complete removal of existing treatment of old plastered surface of wall and applying two coats of cement base paint , including preparation complete all as specified and directed.
M & L for preparation of old decorated plastered or unplastered surfaces and apply one coat of white wash on walls including cornices etc all as specified and directed
Dismantling structural steel work including doors, gates but excluding framed truss, complete all as specified and as directed.
Supply and fix steel rolling shutters, 1.25mm thickness of laths, with or without ball bearing, as specified including top cover, anchoring rod, hasp and stape and one shop coat primer, errected in position as indicated, complete pull push or manual type complete all as specified and directed.
S&F safety lever locks mild steel with 4 levers for rolling shutters complete all as specified and directed.
S&F ball bearing for shutters complete all as specified and directed.
Demolition of cement concrete in ground floor and paving n. exc. 15cm thickness (below or above ground level) complete all as specified and directed.
M&L for 50 mm thick PCC type C2 ,1:3:6 ( using 40 mm graded stone aggregate) as in plinth protection and path finishing the surface without using extra cement etc complete all as specified and directed.
Taking down carefully existing point wiring aluminum/ copper conductor for light or fan or socket or power etc on wooden batten or in conduit including fittings and accessories like switches, sockets, lights fitting, regulator, wooden board and making good disturbed portion to match with existing complete all as specified and directed.
Taking down fan, sealing cable end, dismantling blades and removing fan blades and deposited to store complete all as specified and directed.
Material & labour for concealed point wiring in repair complete including necessary chasing and cutting with single core 1.5 Sqmm (nominal area) PVC insulated and unsheathed cable 1100 volts multistranded, copper conductor cable (FRLS) drawn through and including PVC concealed conduit not less than 20mm dia bore medium grade (ISI marked) and accessories like bends, tees, junction boxes etc, fix on wall or ceiling surfaces all as specified including 1.5 sqmm , FRLS , copper multistranded cable as earth wire including sunken pressed steel terminal boxes and bakelite laminated white/ coloured top sheet cover 3.0 mm thick , for One light point / fan point / call bell point controlled by one way switch complete all as specified and directed.
All as per description of srl item No 53 here-in-before but socket out let 3 pin, 5 Amp on independent board complete all as specified and directed.
All as per description of srl item No 53 here-in-before but socket out let 3 pin, 5 Amp on same board with other switch complete all as specified and directed.
All as per description of srl item No 53 here-in-before but socket out let 3 pin, 15 Amp on independent board with 4.0 sqmm PVC insulated copper conductor cable 1100 volt grade with continuous PVC insulated copper conductor cable 4.0 square as earth lead complete all as specified and directed.
Supply and fix switch piano flush type colour matching with surrounding surface, 15 Amps, 240V AC, single pole, one way complete all as specified and directed
Supply and fix socket out let 2 in 1, 2 pin & 3 pin 15 Amps flush type colour matching with surrounding surface complete all as specified.
Supply and fix switch piano flush type colour matching with surrounding surface, 5 Amps, 240V AC, single pole, one way complete all as specified and directed
Supply and fix socket out let 2 in 1, 2 pin & 3 pin 6 Amps flush type colour matching with surrounding surface complete all as specified.
Supply and fix ceiling rose surface type bakelite 65 x 50 mm three terminal PVC / Polycarbonate isolated body complete all as specified.
Supply & fix LED light fitting 22W retrofit including LED lamp with 2100 lumen output with internal surge protection device of 4KV with voltage band of 140-280V CRI-6500K (White light) fixtures box type with retrofit LED rod 22 watt and connecting electrically to ceiling rose using PVC insulated and overall sheathed flexible copper conductor of size 0.75mm 3 core complete all as specified and directed. Make :Havells cat part No. LUMLINEPLUSBS22WLED865SPCSS or equivalent as mentioned in appendix 'B'
Supply and fix in replacement fan regulator, electronic type, five steps single phase, including connection complete all as specified and directed.
S&F ceiling fan and connecting up incl provision of cable from ceiling rose to fan complete all as specified and directed
Supply and fix in repairs lamp holder PVC/Polycarbonate with back plate with and incl 15 watts LED lamp suitable for batten fittings including connecting up with twin core twisted flexible copper conductor cable complete all as specified and directed.
Supply and fix sheet metal enclosures for DB's with 200 Amp rated bus bar double door class IP-43 epoxy coated inside and outside 12 way SPN 230 volts complete all as specified and directed
Supply and fix isolator single pole & neutral 30 to63 Amps 230 volts one way, complete all as specified and directed
Supply and fix MCB SP 6 to 32 Amps, 240 volts, B curve one way complete all as specified and directed.
Supply and fix sheet metal enclosures for DB's double door TPN 415 volts 4 way suitable for 100 Amps MCCB class IP-43 epoxy coated inside and outside, detachable gland plates flush/mounted for MCBs and MCCB fitted with bus bar complete all as specified and directed.
Supply and fix MCCBs fixed thermal and fixed magnetic type of rating 100 amps with breaking capacity 16 KA complete all as specified and directed.
Supply and fix isolator 30 to 63 amps 4 pole 240/415 volts, 50HZ, 10KA, complete all as specified and directed
Supply & laying 40mm dia GI tubing light grade complete with all fittinggs (ISI Marked) laid in trenches/fixed to wall and ceiling or laid in roads or fixed to poles/ DB for cable protection complete all as specified and directed.
Taking down XLPE insulated, armoured heavy duty electric cable with aluminium conductor of any size/any type complete all as specified and directed.
Supply & laying cable XLPE insulated screened PVC bedded galvanised steel strip or wire armoured heavy duty electric cable with stranded aluminium conductor of size 10 sqmm 2 core, 1100 volts grade, including lugs & fitting complete all as specified and directed.
Excavation in trenches, not exceeding 1.5m wide and not exceeding 1.5m in depth for foundation, etc and getting out in soft/loose soil complete all as specified and directed.
Returning filling in layers including leveling watering and well ramming in layers not exc. 25cm thick complete all as specified and directed.
Removing excavated material n not exc. 50m and depositing where directed at a level n. exc. 1.5m above the starting point complete all as specified and directed.
Supply and spread river sand in trenches as cable cushioning 8 cm below the cables and 15 cm above the cables all as directed and directed Note : Punned down thickness shall be measured.
Supply and lay old size sub class ‘B’ bricks laid flat in trenches over the cable with the length of brick perpendicular to the direction of cable length, adjacent/abutting each other complete all as specified and directed
Material and labour for earthing complete with galvanized steel earth plate electrode 600x600x6 mm thick burried directly in ground (earth pit not less than 2.25 mtr deep below ground level) with top edge of the plate not less 1.5 mtr deep below normal ground level connected to GI earth wire 4 mm dia connected to earth plate by means of nut, bolts, check nut & washer of galvanized iron or steel, GI earth wire will be protected by 15 mm dia GI pipe 'light grade', watering pipe 20 mm dia GI 'light grade', GI wire meshed funnel, alternate layer of char coal and salt on all side to earth plate upto thickness of 150 mm, filling of black cotton soil in earth pit upto ground level,PCC chamber recessed for and including RCC cover including all necessary excavation & earth work,earth wire connected to O/H continuous earth wire on pole/DBs,testing the earthing after completion complete all as specified and directed. Note :- (I) Earth pit shall be constructed 50cm from the side of excavation to avoid sinking of pit (II) PCC chamber shall be (1:3:6) using 20mm graded stone aggregate and 50mm thick RCC (1:2:4) type B-1 cover slab reinforced with 8mm dia TMT steel bars @ 100mm c/c both ways complete all as specified and directed.
M/S RAJESH CONSTRUCTION COMPANY
G S TRADERS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .