Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹34.3 LAccepted-AOC FLAT NO 10 S NO 98 PLAT NO 78 SAI SAYAJI PARK A RIGHT BHUSARI COLONY KOTHRUD PUNE 411 038 | PUNE | MAHARASHTRA | 411038 | L1 | Accepted-AOC Being lowest | |
| 2 | L2₹35.7 L+₹39,830 (1.13%)Rejected-Finance | L2 | Rejected-Finance Greater than lowest | |
| 3 | L3₹36.2 L+₹89,147.50 (2.52%)Rejected-Finance | L3 | Rejected-Finance Greater than lowest | |
| 4 | L4₹36.7 L+₹1.4 L (3.84%)Rejected-Finance | L4 | Rejected-Finance Greater than lowest |
Tender Value
₹43.7 L
EMD Value
₹87,320
Closing Date
14 Mar 2024, 6:00 pmClosed
Lt Col Manish Kumar
GE (P) NDA Khadakwasla
ADDN ALTERATION REDECATION OF DELHI BLOCK SHED NO 1 AND SHED NO 2 AT PEACOCK BAY AT NDA KHADAKWASLA UNDER GE P NDA KHADAKWASLA
2024_MES_642310_1
GE (P)/ TOKEN No 04 of 2023-24
Open Tender
Civil Works
Item Rate
180 days
Khadakwasla
Please refer tender documents
7 documents required · 7 mandatory
₹500
GE (P) NDA Khadakwasla
₹87,320
Yes
2 Apr 2024
15 Feb 2024
20 Mar 2024
15 Feb 2024
14 Mar 2024
29 Feb 2024
Amount
S&F Pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50mm of an colour having tensile strength of 550Mpa as in roof covering/cladding to wall, fixed with self tapping screws, Including dismantling Plain or corrugated steel sheeting, any gauge, thickness, including Nainital or similar pattern roof coverings complete all as specified and directed by Engineer-in-Charge
S&F Pre-painted galvalume aluminium zinc coating GI based plain steel sheet 0.50mm of an colour having tensile strength of 550Mpa as in roof covering/cladding to wall, fixed with self tapping screws, Including dismantling Plain or corrugated steel sheeting, any gauge, thickness, including Nainital or similar pattern roof coverings complete all as specified and directed by Engineer-in-Charge
S&F 0.63 mm thick Galvanised, corrugated mild steel sheeting with two corrugations side lap,fixed with L-type or J-type or cranked hook bolts, in roofs, walls etc. with grade of zinc coating 275,Including dismantling Plain or corrugated steel sheeting, any gauge, thickness, including Nainital or similar pattern roof coverings complete all as specified and directed by Engineer-in-Charge
Dismantling structural steel work including doors, gates , Rafters, Purlins and similar work etc and refixing/shifting with and including drilling, welding or fixing with screws, bolts etc complete all as specified and directed by Engineer-in-Charge
S&F Roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc for Fe 410 -W (Gde- E-250) quality A, complete all as specified and directed by Engineer-in-Charge
S&F Steel frame work in tubular trusses (Square/rectangular hollow sections) as in sun shade/Rain guard frame in any height including fixing with necessary fasteners ,special shaped washer etc. complete using ERW or induction butt welded tubes conforming to I. S.1161-1979 grade St.-240 complete all as specified and directed by Engineer-in-Charge (Note:- The quoted rates including necessary sacffolding in any height ,cutting to dead length where required, notching, drilling, fitting, riveting and/or welding or connecting with bolts and nuts (including fixing rivets or Fasteners bolts and nuts), providing and fitting angle cleats, fish plates, gusset plates etc., also for wedging, plumbing, turning up and fixing deemed to be included in quoted rate and nothing extra on this account will be admissible.)
S&F Mild steel Expandable Fastener nut & bolts type (machine made) with hexagonal /square heads at one end & screwed the other/ screwed both ends, each screwed end to be fitted with washers & one hexagonal or square nut,length of bolt exc 5cm but n exc 10cm long dia of shank 5 to 10 mm complete all as specified and directed by Engineer-in-Charge
S&F Pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50mm of an colour having tensile strength of 550Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and directed by Engineer-in-Charge
Cutting chases, pinning in, making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc.; and cutting chases for concealed water tubing or concealed conduit wiring, etc. and making good, cutting exceeding 10 cm but n.exc 20cm girth complete all as specified and directed by Engineer-in-Charge
Preparing surfaces of old painted steel surfaces of any description over 10cm width or girth and applying one coat of Aluminium paint complete all as specified and directed by Engineer-in-Charge (Note:-The quoted rate deemed to be included for Use of all necessary scaffoldings for any height or position and nothing extra on this account will be admissible.)
Preparing surfaces of old painted steel surfaces of any description over 10cm width or girth and applying two coats of Aluminium paint complete all as specified and directed by Engineer-in-Charge Note:- The quoted rate deemed to be included for Use of all necessary scaffoldings for any height or position.
Preparing surfaces of new steel surfaces of any description over 10cm width or girth and applying two coats of Aluminium paint over a coat of Aluminium red oxide primer complete all as specified and directed by Engineer-in-Charge Note:- Rate to be included for Use of all necessary scaffoldings for any height or position.
Preparing surfaces of new steel surfaces of any description over 10cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed by Engineer-in-Charge Note:- The quoted rate deemed to be included for Use of all necessary scaffoldings for any height or position.
Demolition of cement concrete in ground floors and pavings (unreinforced) n.exc 15 cm thickness (below or above ground level) complete all as specified and directed by Engineer-in-Charge
M&L 100 mm thick Cement concrete type B-1, 1:2:4 (20mm graded aggregate) and finishing the surface even and fair by brooming with using extra cement complete all as specified and directed by Engineer-in-Charge
Forming Contraction (Dummy) joints 75 mm deep x 10mm wide, filled with sealing compound grade 'A'.complete all as specified and directed by Engineer-in-Charge.
M&L for 75mm thick PCC 1:3:6 type C-2 as in plinth protection including cutting grooves at every 2mtr interval and fillling with bitumin sand mix and finishing the surface even and smooth with using extra cement complete all as specified and directed by Engineer-in-Charge.
Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out in soft/loose soil complete all as specified and directed by Engineer-in-Charge.
M&L for Cement concrete (1:4:8) type D2 40mm (graded Stone aggregate) in foundations, filling and mass-concrete complete all as specified and directed by Engineer-in-Charge.
M&L Brickwork with fly ash bricks (old size bricks), straight or curved on plan exc 6 m mean radius, built in cement mortar 1:6 complete all as specified and directed by Engineer-in-Charge.
M&L Cement concrete Type C2, 1:3:6 (40 mm graded aggregates) as in surface channels and drains complete all as specified and directed by Engineer-in-Charge.
M&L Cement concrete Type B0, 1:2:4 (12.50 mm graded aggregates) as in coping complete all as specified and directed by Engineer-in-Charge.
M&L for 15mm thick rendering in CM (1:4) including WPC on brick work or concrete surface as in wall including finishing the surfaces even and smooth complete all as specified and directed by Engineer-in-Charge.(Note : WPC will be measured and paid separately).
Supply only water proofing liquid compound solution complete all as specified and directed by Engineer-in-Charge.
Returning , filling in, including spreading leveling, watering and well ramming in layers n.exc 25cm in any type of soil complete all as specified and directed by Engineer-in-Charge.
Removing excavated any type of soil n.exc 50m and depositing where directed at a level n.exc 1.5m above the starting points complete all as specified and directed by Engineer-in-Charge.
Taking down chowkhat or frame with shutter (without taking off shutter from the frame ) of exc 1.5 sqm and n exc 4 sqm each complete all as specified and directed by Engineer-in-Charge.
S&F Powder coated (minimum thickness of powder coating 50 micron) Anodised aluminium frame for doors, windows, ventilators with one or more rebates including joining cleat for fixing etc. complete all as specified and directed by Engineer-in-Charge.
S&F Powder coated (minimum thickness of powder coating 50 micron) Anodised aluminium door shutters, aluminium section weighing 0.55 kg/ m including necessary joining cleats, glazing clips, ruber neoprene packing, handles 2 Nos in each door, hinges, anodised aluminum snap beading screws etc. complete all as specified and directed by Engineer-in-Charge.
S&F 4.8 mm thick Sheet glass, ordinary quality and glazing with oil putty/rubber packing/ anodised aluminium snap beading in squares not exceeding 0.5 Sqm in each pane including fixing of Solar control film 50 micron reflective type sticked to glass panes as per instructions of manufacturers complete all as specified and directed by Engineer-in-Charge.
M&L for Double action floor spring hydraulically regulated made up of minimum 1.25 mm thick aluminium alloy sheet foundation box, main body with stainless steel cover, governing pivot made of brass,other parts made of mild steel heavy duty and fixed complete all as specified and directed by Engineer-in-Charge.
S&F 100 mm size Mild steel 4 Leavers Mortice lock, vertical type, including escutcheon plates and two keys, complete all as specified and directed by Engineer-in-Charge.
Demolition and breaking up drain pipes PVC or AC pipe set in cement mortar for 100mm bore pipe complete all as specified and directed by Engineer-in-Charge.
S&F for 110mm bore PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to walls/floors complete all as specified and directed by Engineer-in-Charge.
S&F for 110 mm bore PVC (SWR) bends any radious with access door complete all as specified and directed by Engineer-in-Charge.
Dismantling of 75mm bore cast iron/ reinforced concrete drain pipes/ PVC (SWR) pipes, jointed in any type and taking out from wall/ceiling/floor/trenches and any position complete all as specified and directed by Engineer-in-Charge.
S&F 75 mm bore PVC (SWR ) pipes single socketed, in any lenth with rubber ring fixed to wall/floor with suitable MS/PVC clamp including dismantling the old damaged pipe complete all as specified and directed by Engineer-in-Charge.
S&F for 75mm bore PVC (SWR) bends any radious provided complete all as specified and directed by Engineer-in-Charge.
S&F for 75mm bore PVC (SWR) bends any radious provided with access door complete all as specified and directed by Engineer-in-Charge.
Dismantling floor hearth or wall tiling including cement mortar bedding ( but not backing) and removing rubbish off the premises complete all as specified and directed by Engineer-in-Charge.
Taking down of existing un-serviceable tarfelt / bituminous membrane on roof and parapet of any roof height carefully by cutting chiseling, cleaning the surface by scraping, brooming, brushing etc and removing the rubbish from site complete all as specified and directed by Engineer-in-Charge.
M & L water proofing treatment to RCC roof slab, sunkan slab, walls, chhajjas etc, shall be carried out as specified below and as directed by Engineer-in-Charge including following (a) Preparing plastered surfaces of roof slab, walls, chhajjas etc, by brooming with broom sweeping free from dirt dust etc & evenly applying a coat of approved bitumnous primer @ 0.7 kg/Sqm of area complete all as specified. . (b) M&L for APP based polymeric membrane minimum weighing 3.5 Kg/Sqm and minimum 3mm thick reinforced with polyster non woven fabric ( wt not less than 150 gms /sqm) laid over primed surface. (c) Finally applying applying one coat of aluminum paint including preparation of surface.
M&L 40 mm thick PCC 1:2:4, type B-0 using 12.5mm graded aggregate as in sub base/roof padding and leveling course etc. complete all as specified and directed by Engineer-in-Charge.
M&L for Polished kota stone 20 to 25 mm thick laid over 20 mm thick screed bed in CM 1:3 with WPC jointed & pointed in CM 1:2 mixed with WPC as per manufacturer's instructions.(for Accessible roof) complete all as specified and directed by Engineer-in-Charge.
M&l for carrying out water proofing treatment to sunken slab, floors and wall of WC, WHB and urinals, as mentioned below :- (a) Special tratment to toilet floor by demolition of existing treatment of any description and thickness,removal rubbish outside MD land (b) Clean the sunken portion of toilet/Bath/WC/Kitchen throughly to remove laitance, dirt, dust, etc. (c) Form angle fillet of size 40 mm x 40 mm along the junction of wall and floor using polymer modified mortar ("Dr Fixit" Pidicrete URP" or eqvt) (d) Sanitary pipes entering through walls and floor shall be sealed with "Dr Fixit Bathseal Tape" and the gaps to be grouted with non-shrink cementitous grout "Dr Fixit Bathseal Grout" or eqvt. Nahani traps, etc to be fitted securely and the gaps around it to be grouted in the same manner. (e) Apply one coat of a Bitumen-modified polymer coating "Dr Fixit Bathseal Plus" or eqvt on all angle fillets by brush and cover it with 100 mm open woven mesh when it is still wet. Apply second coat of the same coating on the angle fillets and allow it to dry completely. (f) In the remaining area, in dry state condition brush apply first coat of the same coating and further apply second coat when first coat is dry. Extend the coating upto 150 mm above the FFL. Above FFL, another cementitious waterproof coating "Dr Fixit Pidifin 2 K" or eqvt can be further applied right upto 2.1 mm to waterproof the shower area also, it is a bathroom or bath cubicles of a sanitary annex and apply second coat after 6-8 hours and allow to dry completely. (g) After 2 to 3 days, sunken portion must be overlaid with a 50mm thick concrete screed M-15 type B-0 mxed with integral WPC(liquid) laid to be slope 1:60 towards outer face of wall incl flll up the sunken portion with lean concrete 1:5:10 type E2 etc complete all as per manufacturers instruction and directed by Engineer-in-charge. Note:- Unit rate quantitiy deems to be included for all above specified activities under this BOQ item. However the net area to be measured for payment is only sunken portion at Bath/WC/Kitchen and no any vertical surface to be measured separately.
M&L for Joint free Non-skid Ceramic colour tiles 7 to 8mm thick (square/ rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match including M&L 15 mm thick screed bed or bedding layer in cement mortar (1:4) complete complete all as specified and directed by Engineer-in-Charge.
M&L for Glazed ceramic colour tiles in vertical surface 450 x 300 x 8 mm or 300 x 200 x 7 mm thick any one as directed set and jointed in neat cement slurry and pointed in white or colour cement to match including taking down old backing plaster and including M&L 10 mm thick rendering in cement mortar (1:4) on wall surfaces like dado, skirting etc.complete all as specified and directed by Engineer-in-Charge.
S&F vitreous china wash down water closet pan (pedestal pattern) in repair white coloured with integrated 'P' or 'S' trap outlet including 110mm PVC (SWR) WC connector with lip ring, conection to flush pipe and out going pipe and including plastic water closet seat cover white coloured closed pattern with flat bottom and PTMT hinging device complete fixed in repairs complete all as specified and directed by Engineer-in-Charge.
M&L for PVC (SWR) floor trap plain with grating including jointing with solvent cement dia of outlet 75mm. Including taking down old floor trap any type. complete all as specified and directed by Engineer-in-Charge.
M&L for PVC (SWR) multi floor trap with grating including jointing with solvent cement dia of outlet 75mm. Including taking down old floor trap any type.complete all as specified and directed by Engineer-in-Charge.
S&F LDPE pipes 50mm dia, of pressure rating 6 kg/sqcm fixed to wall or laid in floor etc including necessary pipe fittings and fixing arrangement complete all as specified.complete all as specified and directed by Engineer-in-Charge.
Taking down carefully copper/aluminium point wiring (light/fan/socket) including all accessories wire, casing caping/conduit, screws etc and making good the disturbed surfaces complete all as specified and directed by Engineer-in-Charge.
Taking down unserviceable sub main wiring of any type and size with teak wood battens/Casing capping/PVC Conduit/ and making good disturbed surface complete all as specified and directed by Engr-in-Charge.
Taking down carefully deffective and unserviceable XLPE UG Cable of any size and description from the floor, wall and roof , and disconnected all the connection from Lt Panel boards/DBs and relaying the same serviceable cable on surface drawn through PVC pipe of 50mm dia as directed by the Engr-In-Charge and making good the disturbed surfaces all as specified and directed. Note :- The cost of 50mm dia PVC pipe shall be paid separately in respective item of Schedule.complete all as specified and directed by Engineer-in-Charge.
Taking down old existing Ceiling fans of any type and size from the site and deposite to store before desmantling of roof and point wiring carefully and including Hanging only ceiling fan and connecting up including M & L painting of ceiling fan complete in situ with synthetc enamel paint by spraying including filling cavities with filler one coat after cleaning all dust etc , spray paint of approved make and connect with provision of three core cable from ceiling rose or connector to fan and provision of hook/hole fast and adequate size of down rod to take the load of fan if required.complete all as specified and directed by Engineer-in-Charge.
S&F rigid Non -metallic PVC Conduit of size 50mm dia, heavy duly , inclusive of all tees,bends,elbows,reducers,bell mouth tube ends abd fixing acessories such as couplers,lock nuts,saddles,pipehooks etc complete all as specified and directed by Engineer-in-Charge.
M&L for Point wiring with proper colour coding complete with and including PVC insulated, unsheathed, flexible bright annealed multi stranded copper conductor single core (FRLSH) cables 1.5 Sqmm (22/0.30 mm) 1100 volts grade drawn through in and including heavy grade, rigid non-metallic PVC conduits 25 mm or higher dia as required at site or PVC Casing & Caping ,Totally on walls / floors /ceiling and surfaces on trusses by means of saddles & clips etc including all conduit accessories, fittings including PVC box with cover plate of heavy grade, ISI marked for mounting of switches, sockets fan regulators etc; including 1.5 Sqmm (22/0.30 mm) 1100 V grade PVC insulated FRLS, unsheathed flexible, multi stranded, copper conductor cable(green colour) as continuous earthwire connected to metallic bodies of luminaires/fans etc; at one end and to common earth dolly at other end, complete all as specified and directed by Engineer-in-Charge. for following :-The cost of Chasing & Making surface good deemed to be included in quoted rate.
One light/ceiling Fan/Wall Fan point controlled by one, one way switch 6 Amps 240 Volts.
one 3 pin 6 Amp Socket outlet point on Same board including earth wire as per description given above and connected to common earth and earth terminals.
One 3 pin 6 Amp Socket outlet point on Independent board including earth wire as per description given above and connected to common earth and earth terminals.
All as per description of BOQ item No 57 here -in -before but for 3-pin socket outlet 15 Amps on independent board with cable size 4.0 Sqmm Multi std.copper conductor PVC insulated cable 1100 volts grade with continous 4.0 Sqmm earth wire.
S&F socket outlet 3pin, 6 Amps flush type (ISI Marked) controlled by one way switch complete all as specified and as directed by Engr-in-charge.
S&F Switch piano flush type 6 Amps single pole one way.
S&F socket outlet 2 in 1, 3 pin, 6 and 16 amp flush type (ISI Marked) controlled by one way switch complete all as specified and as directed by Engr-in-charge.
S&F Switch piano flush type 16 Amps single pole one way.
S&F Stepped type electronic fan regulator flush type suitable for ceiling fan of 1200/1400mm sweep
M & L for Point wiring with proper colour coding complete with and including PVC insulated, unsheathed, flexible bright annealed multi stranded copper conductor single core (FRLSH) cables 1.5 Sqmm (22/0.30 mm) 1100 volts grade drawn through in and including heavy grade, rigid non-metallic PVC conduits 25 mm or higher dia as required at site, totally concealed in walls / floors /ceiling and surfaces etc including all conduit accessories / fittings / junction boxes / inspection covers etc of heavy grade, ISI marked with modular metal boxes,cover plate and frame totally concealed in wall surface by means of brass screws and sunk/cupwashers, for mounting of modular switches, sockets fan regulators etc, including 1.5 Sqmm (22/0.30 mm) 1100 V grade PVC insulated FRLSH, unsheathed flexible, multi stranded, copper conductor cable(green colour) as continuous earthwire connected to metallic bodies of luminaires/fans etc; at one end and to common earth dolly at other end, complete all as specified and directed by Engineer-in-Charge. for following :-
One light/Ceiling Fan/Exhaust Fan point controlled by one, one way switch 6 Amps 240 Volts.
one 3 pin 6 Amp Socket outlet point on Same board including earth wire as per description given above and connected to common earth and earth terminals.
one 3 pin 6 Amp Socket outlet point on Independent board including earth wire as per description given above and connected to common earth and earth terminals.
All as per description of BOQ item No 64 here -in -before but for 3-pin socket out let 15 Amps on independent board with 2.5 Sqmm Multi std.copper conductor PVC insulated cable 1100 volts grade with continous 2.5 Sqmm earth wire.
S&F modular switch 1 way ,6A 1 module.
S&F Modular socket 6 A 2/3 Pin 2 module.
S&F modular switch 1 way 16 A 1 module.
S&F Modular socket 6 A/16A 2/3 Pin 2 module.
S&F modular fan regulator, 2 module, suitable for ceiling fan of 1200/1400mm sweep
S&F ceiling rose surface type PVC 50 mm dia 3 terminals including PVC mounting block complete all as specified and as directed.
S&F of decorative 4 feet tube set(T8) with motion sensor, LED lighting fixture with extruded aluminium heat shrink, environmental friendly, energy efficient ready to use pack of capacity 18Watt LED, accessories internally pre-wired and including connecting up with twin core twisted flexible copper conductor cable with suitable size.complete all as specified and directed by Engineer-in-Charge. Make : Luker product code - LT818SR or equivalent in Havells and Phillips or techo commercially equivalent model in makes as per Appendix 'C'.
Supply and fix light fitting 10 Watt minimum dimension 154mm x 57 mm, GESTO IP-65, Ceiling Light, circular type ABS plastic body with PC diffuser including required accs, fixing arrangements, connecting with three core copper wire from light source to light fitting complete all as specified and directed by Engineer-in-Charge. Make : Luker product code - LBKRDSL10 or equivalent in Bajaj and Phillips or techo commercially equivalent model in makes as per Appendix 'C'.
Re-fixing of doom light fittings of any make and description retreved from the site against taking down of point wiring all as specified and directed by Engr-In-Charge. Note : Old and unserviceable old type CFL only to be replaced with LED bulb 9Watts. Cost of the LED bulbs shall be paid separately with respective item of the Schedule.complete all as specified and directed by Engineer-in-Charge.
S&F LED Bulbs 9W suitable of doom lights Holder type t complete all as specified and directed by Engineer-in-Charge.
S&F heavy duty industrial wall fan (Steel Body ) of sweep 750 mm with single phase suitable for 230 volts 50 HZ,1400 rpm and connecting up complete including provision of 3 core flexible cord from ceiling rose to connector of fan with cable of suitable size.complete all as specified and directed by Engineer-in-Charge.
S&F LED Flood lights of 150Watts ,energy saving, environmental friendly long life, die cast aluminium body with toughned glass IP66, including all accessories with 3 core flexible copper wire mounting on beam,surfaces or trusses with clamp, Nut Bolts and washers etc required at site for fixing luminaire.complete all as specified and directed by Engineer-in-Charge.
M&L for Earthing complete with galvanised steel earth plate electrode 600 x 600 x 6.0 mm thick, buried vertically in ground (Earth pit not less than 2.25 metres deep below normal ground level and top edge of the plate not less than 1.5 m below ground level), connected to galvnised steel earthing lead wire 4 mm dia, by means of bolts, nuts & checknuts and washers etc; GI pipe 15 mm dia medium grade pipe for protection of G.I earth lead wire, both to be provided to the extent of 7.5 metres, all as shown on electrical plate No 3 of MES SSR-2009 Part-I, other end connected to electrical main switch board (inside the bldg)/transformer/LT kiosk/HT lightening arrestors etc. including GI protection pipe buried in ground, laid under floors/plinths or fixed on walls or concealed in walls etc; with provision of mixture of charcoal dust & common salt packed upto minimum 150 mm all around the earth plate , including PCC 1: 2 : 4 type B-1 earth pit with M.S angle iron frame, cast iron cover with locking arrangement, with G.I 20 mm dia light grade pipe and M.S funnel with wire mesh for watering arrangement, including necessary excavation and earth work in any type of soil / strata & testing on completion including fill up the earth pit with soil for best result and removal of excavated material from the site complete all as specified and directed by Engineer-in-Charge. Note :-The Earth protection pipe & earthing lead wire upto and including 7.5 m length is deemed to be included in unit rate quoted by the contractor.
Supply , laying , testing and connecting of LT UG cables 1100 Volt grade XLPE insulated and PVC sheathed, armoured, with multi stranded aluminium conductor, heavy duty confirming to IS - 1554 part-I, including cable glands, cable lugs in LT panel/ MDB in bldg etc including material and labour for all jointing/connecting material as required, cables laid in trenches/ducts/under plinth floors passing through pipes etc, 4 core 25 Sqmm fixed on wall complete all as specified and directed by Engineer-in-Charge.
S&F of copper cable sheathed three core of size 2.5 sqmm 3 core for phase, neutral and earth wire, round type (2X2.5sqmm+1x2.5 sqmm) in PVC rigid conduit complete all as specified and directed by Engineer-in-Charge.
S&F Grey Plexo box & adaptor with PVC membrane -1 row X 4 module 230V, 50 HZ, IP-55 & IK-09 Class-II, weatherproof cabinets, door and cabinet fully reversible, removable chassis and faceplates, including weatherproof glands, rails qty-1 Nos. complete all as specified and directed by Engineer-in-Charge.
S&F MCB DB 12 way SPN double door sheet metal enclosure factory made suitable for MCB DB's 240 volts with 100 amp rated busbar, neutral & earthing link bar,surface mounting complete including taking down the existing DB of any type & size alongwith its accessories by removing from existing circuits and refixing the new DBs and circuits complete all as reqd at site.complete all as specified and directed by Engineer-in-Charge.
S&F MCB DB 08 way SPN double door sheet metal enclosure factory made suitable for MCB DB's 240 volts with 100 amp rated busbar, neutral & earthing link bar,surface mounting complete including taking down the existing DB of any type & size alongwith its accessories by removing from existing circuits and refixing the new DBs and circuits complete all as reqd at site.complete all as specified and directed by Engineer-in-Charge.
S&F MCB SP 6 to 32 Amps 240V,10 KA breaking capacity , C curve as per IS/IEC 60898-1 2002 with IP 20 protected terminals all as specified including complete connection with copper /aluminium cable lugs with suitable size for incoming and outgoing.complete all as specified and directed by Engineer-in-Charge.
S&F MCB SPN 32 AMP, 240V,10 KA breaking capacity , C curve as per IP 20 protected terminals all as specified including complete connection for incoming and outgoing.complete all as specified and directed by Engineer-in-Charge.
S&F MCB TPN-32-63 Amp, 415V,10 KA breaking capacity , B curve as per IP 20 protected terminals all as specified including complete connection for incoming and outgoing.complete all as specified and directed by Engineer-in-Charge.
M&L for Sub Main wiring with PVC insulated FRLSH grade cable LT 1100 Volts grade, 2 x 6 Sqmm with one continuous earth wire of 6 Sqmm, PVC insulated unsheathed, multistranded with stranded copper conductor drawn through concealed conduit, including PVC conduit medium grade not less than 25 mm in any type of wall, roof, etc, with all connected fittings and make good to match with the existing surfaces after completion alongwith one continuous earthwire and connected to the common earth complete all as specified and directed by Engineer-in-Charge. Note :- (i) 2 runs of 6 Sqmm and One run of 6 Sqmm earth wire and including 25mm PVC pipe, elbow, bends etc will be measured as One Running Meter (ii) Cutting in chases and pointing in brick wall/Stone Wall will be done by contractor without any extra cost. (iii) Making good of distrubed surfaces matching with existing finishes will be done by contractor without any extra cost
S&F search light Auto Revolving with Xenon Lamp 2000W,AC 220V, 50 Hz, outdoor type,waterproof level IP54, Cool white in colour, autonomous running around 110 DHS suitable for large performance,including all connected accessories and fixing arrengements reqd at site complete all as specified and directed by Engineer-in-Charge.
S&F single pointed air termination aluminium rod , 12 mm dia, 300 mm long. Fixing on roof with 25 mm light grade GI pipe 1.2 mtr long mounted on suitable size PCC block and down conductor aluminium earth strip of 25 x 3.15 mm size , drilled and fixed on pipe with suitable size epoxy based insulator including necessary fixing arrangement GI nuts, bolts, washers, MS clamps etc complete all as specified and directed by Engineer-in-Charge. Note : GI pipe & PCC block shall be measured & paid seperately .
S&F aluminium strip 25 mm x 3.15 mm fixed on insulated epoxy insulator & fixing screws, nut bolts etc for roof and down conductor upto test point terminal block complete all as specified and directed by Engineer-in-Charge.
S&F Galvanised iron strip 32mm x6 mm burried in ground /laid in floor/fixed to wall/fixed on insulated epoxy Insulator , fixing screws etc conductor upto test point etc. complete all as specified and directed by Engineer-in-Charge.
M&L for test point terminal block made of gun metal or phosphous bronze size 75 X 75 X 25 mm drilled and screwed including 3 Nos 8mm dia 25mm long hexagonal screws. Fixed on insuated epoxy Insulator & fixing with screws ,nuts ,boltsetc complete all as specified and directed by Engineer-in-Charge.
M&L PCC Block masonary with solid blocks exc 10 cm in width and setting in mortar type B1 1:2:4 (20mm graded aggregate) complete all as specified and directed by Engineer-in-Charge.(Size of block 10x0.3x0.3x0.3)
S&F GI Pipe medium grade 40mm bore ISI marked with all necessary fittings for fixing of air termination at 1.2 m height at roof & earth strip protection etc laid on wall, floor and treanches or where is reqd at site complete all as specified and directed by Engineer-in-Charge.
Dismantling and disconnecting of existing earthing GI strip any size and shape from the wall /roof /floor and Air Terminations from Delhi block bldg and Refixed the same Air termination and earthing Strip retreved from the site properly duly provided new insulated epoxy insulator & fixing screws, nut bolts etc for roof and down conductor upto test point terminal block complete all as specified and directed by Engineer-in-Charge. Note : Rusted and detrioted earthing strip may please be removed and New earthing strip shall be provided. The cost of New Earthing strip and PCC Block Masonry shall be paid in relevent items of schedule.
M & L for Earthing complete with galvanised steel earth plate electrode 600 x 600 x 6.0 mm thick, buried vertically in ground (Earth pit not less than 2.25 metres deep below normal ground level and top edge of the plate not less than 1.5 m below ground level), connected to galvnised steel earthing strip of size 32x 6mm dia, by means of bolts, nuts & checknuts and washers etc; GI pipe 40mm dia medium grade pipe for protection of G.I earth strip, both to be provided to the extent of 7.5 metres, all as shown on electrical plate No 3 of MES SSR-2009 Part-I, other end connected to electrical main switch board (inside the bldg)/transformer/LT kiosk/HT lightening arrestors etc. including GI protection pipe buried in ground, laid under floors/plinths or fixed on walls or concealed in walls etc; with provision of mixture of charcoal dust & common salt packed upto minimum 150 mm all around the earth plate , including PCC 1: 2 : 4 type B-1 earth pit with M.S angle iron frame, cast iron cover with locking arrangement, with G.I 20 mm dia light grade pipe and M.S funnel with wire mesh for watering arrangement, including necessary excavation and earth work in any type of soil / strata & testing on completion including fill up the earth pit with soil for best result and removal of excavated material from the site complete all as specified and directed by Engineer-in-Charge. Note :- Earth protection pipe & earthing lead wire upto and including 7.5 m length is deemed included in unit rate quoted by the contractor.
PAWAN B SHINDE
M/S K.D.MATE
M/S Narendra Construction
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .