Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Tender Updates
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹47.2 LAccepted-AOC 1ST 2ND FLOOR PLOT NO 13 C 13 3 RAMA ROAD SIDE INDUSTRIAL AREA NAJAFGARH ROAD DELHI 110015 INDIA | WEST | DELHI | 110015 | L-1 | Accepted-AOC Being lowest and reasonable | |
| 2 | L-2₹50.9 L+₹3.6 L (7.70%)Rejected-Finance | L-2 | Rejected-Finance Not being lowest bidder | |
| 3 | L-3₹51.3 L+₹4.1 L (8.60%)Rejected-Finance | L-3 | Rejected-Finance Not being lowest bidder | |
| 4 | L-4₹62.3 L+₹15.1 L (31.9%)Rejected-Finance SHIV BARI ROAD NEAR KASUMAL HOTEL BIKANER 334003 RAJASTHAN | BIKANER | BIKANER | RAJASTHAN | 334003 | L-4 | Rejected-Finance Not being lowest bidder | |
| 5 | Rejected-Technical | - | Rejected-Technical Not admitted since Firm is two class below from eligible class |
Tender Value
₹50.0 L
EMD Value
₹1.0 L
Closing Date
29 Jan 2024, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
CWE Bathinda
HQ CWE Bathinda
REPAIR/MAINT OF VCBs AND CONNECTING ITEMS UNDER GE (U) BATHINDA AT BATHINDA MIL STN
2023_MES_634185_1
CWE BTD/TOKEN-58/2023-24
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
Bathinda Mil Stn
As per NIT
7 documents required · 7 mandatory
₹1,000
GE (U) Bathinda
₹1.0 L
HQ CWE Bathinda
13 Apr 2024
23 Dec 2023
31 Jan 2024
23 Dec 2023
29 Jan 2024
15 Jan 2024
2 Jan 2024
Amount
Material & labour for Repair,Maitainance & Servicing of 11KV HT VCB indoor/outdoor type complete including the following (a) Taking out 11KV HT VCB of 400/630/800 Amp rating trolley from HT Panel after switching off electric supply. Removing all mechanical/electrical/control system for proper functioning e.g. spring charge system, triping system, remote operation, indication system, upward-downward/in-out movement of HT VCB trolley,etc including opening the VCB trolly & checking the quality of insulating material,vaccum system complete. Replace defective parts, fixed/ moving contacts and blowing out dust and applying the proper lubrication/ greasing with AP-3 grease and reassembling the VCB including connection to HT panel and make the VCB functional to the entire satisfaction of and as directed by the Engineer-in-charge. Notes :- (i) The VCBs are installed are of different type of makes installed at site like Crompton Greaves, Alstom, Areva,ABB Schneider,Siemens,C&S, etc. (ii) After servicing, test certificate of VCBs by OEM/GST Registered firm shall be submitted to Engr-in charge
Material & labour for Repair and maintanance of relay set (O/C and E/F relays) of any make for 11KV VCB/RMU panel, removing and refixing (the contacts NO+NC should be cleaned by CTC solution and adjust if electromagnetic) with faulty part replaced and calibrate the relays by relay testing kit & proper setting as per reqd load & time delay and fixing the relay set in HT panels complete all as specified and directed by Engr-in-charge. Notes :- (i) Testing shall be carried out by primary and secondry current injection kit. (ii) Spare parts shall be measured and paid separately under supply only. (iii) The tripping system should be in accordance with the incomer of the affected feeder and setting should be maintained such that fault does not carry beyond the particular feeder due to overload, 3 phase fault, earth fault etc. (iv)The VCBs are installed are of different type of makes installed at site like Crompton Greaves, Alstom, Areva, Schneider,Siemens,C&S, etc. (v) After servicing, test certificate of VCBs by OEM/ GST registered firm shall be submitted to Engr-in charge
Supply only SF6 gas suitable for 132KV breaker complete all as directed by Engr-in-charge.
Supply only trip/closing coil suitable for HT, VCB/RMU, operating on 24/110/220 volt system and testing complete all as directed by Engr-in-charge.
Supply only replacement of 220/24/110 Volt DC Contactor with 2 No+2NC complete all as specified as directed by Engr-in-charge.
Supply only Motor cut off limit switch suitable for HT 11 KV VCB/RMU complete all as directed by Engr-in-charge.
Supply only Jaw/tulip shawer contact suitable for HT 11 KV VCB/RMU complete all as directed by Engr-in-charge. Make : CG/ALSTOM/AREVA/SCHNIEDER/SIEMENS/ABB
Supply only torsion/close spring suitable for HT 11 KV VCB/RMU complete all as directed by Engr-in-charge. Make : CG/ALSTOM/AREVA/SCHNIEDER/SIEMENS/ABB
Supply only racking rod with socket suitable for HT 11 KV VCB complete all as directed by Engr-in-charge. Make : CG/ALSTOM/AREVA/SCHNIEDER/SIEMENS/ABB
Supply only Push Button element with one NO / NC complete all as directed by Engr-in-charge.
Supply only Spring charging handle suitable of VCB charging as per sample all as specified and directed by Engr-in-charge.
Supply only TNC switch with wiring suitable for 11 KV VCB complete all as directed by Engr-in-charge.
Supply only in replacement heater assembly suitable for moisture control in VCBs as per sample complete all as specified
Supply & testing of spring charging motor for outdoor/indoor type, 11KV, VCB/RMU,operated on 230/110/24 volts AC/DC,with charging time less than 15 sec of approved rating complete all as specified and directed by Engr-in-Charge.
Supply and fix in repair multifunction meter with digital display suitabale for measuring 11 KV electrical parameters( Voltage, Amp, power factor, frequcncy. Kwh, harmonics upto 31 level) complete all as specified and directed
Supply only Auxiliary switch 6 NO/6NC complete all as directed by Engr-in-charge.
Supply & fixing in replacement indication lamp (LED type) Red or Yellow or Green colour suitable for 110 volts AC / 110 volt DC / 30 volts DC (as required at site) complete all as specified and directed by Engr-in-charge.
Supply only in replacement of Current transformer (CT) ratio 200/100/5-5A, 50 Hz, 15 VA, accuracy class-I & 5P-10 , short ckt time 18.4 KA for 1 sec, as per IS-2705 epoxy type suitable for 11 KV, VCB breaker including all necessary fixing arrangements and proper wiring and connections complete all as specified and directed by Engineer-in-Charge
M & L in replacement of MCB SP 'C' curve 6 to 32 Amp for fixing in control circuit of VCB complete all as specified and directed by Engineer-in-Charge
M & L in replacement of MCB SPN 'C' curve 6 to 32 Amp for fixing in control circuit of VCB complete all as specified and directed by Engineer-in-Charge
Material, labour & T&P for repair and maintenance of battery bank of output 110/24 Volt with following jobs:- (a) Checking the terminals of battery and cleaning it and pouring of distilled water into it. (b) Checking of terminal voltage output of individual battery and locating the fault if any (c) checking the DC supply to the relay and auxiliary units installed in the VCB (d) Checking the battery charger for the charging of the battery bank and make it serviceable.Note:- The cost of parts to be included in quoted rate nothing shall be paid extra for this amount.
M&L in repair of Earthing complete with copper earth plate electrode, 60x60cmx 3.15mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5 metres below normal ground level, connected to copper strip of 20x 3 mm by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No. 5 connected to earthing test point all as specified or indicated including testing on completion as per direction of Engr-in charge.
Material & labour for Repair,Manitenance of 11KV HT Capacitor bank outdoor/Indoor type complete including the following (a) Checking the serviceability by Meggaring of each capacitor unit of any capacity.(b) Replace defective parts and blowing out dust and applying the proper lubrication/ greasing with AP-3 grease including connection to HT panel and make the capacitor bank functional to the entire satisfaction of Engineer-in-charge. .
Material & labour for Repair,Maintenance of 11KV HT Potential Transformer complete including the following (a) Checking the serviceability of each PT unit of any capacity.(b) Replacement of defective parts i.e fuse of any capacity,connection wire etc and blowing out dust and applying the proper lubrication/ greasing with AP-3 grease including connection to HT panel and make the PT functional to the entire satisfaction of Engineer-in-charge. .
Supply, Installation, testing , Commissioning in replacement of battery bank 24 Volts DC-12 Nos tubular maintenance free batteries 2Volts 100AH with necessary items required for connection of batteries including battery Stand all as specified and directed.
S&F in replacement 24 Volt pure sine wave inverter of 2 kVA DIP switch, auto mode 50 HZ, 6 stage charger for large battery life, input voltage 100 to 280 V, low cut recovery input voltage 90 V, high cut input voltage 280V, recharge time max 8 hrs, for 12 battery system, battery boost system, battery charging current 15A, compatible for sealed maintenance free lead acid tubular battery protection against high and low voltage overload, with onsite 36 months warranty complete all as specified. Make- Microtek/Luminous/Sukam
Supply, installation, testing and calibration of relay 110/24V of Microprocessor based three phase relay system to overcurrent, one earth fault protection type for 11 KV breaker, setting range suitable for over current and earth fault with necessary wiring/fitting including dismantling of old IDMT or unserviceable relays.The setting of the relay should be in accordance with the incomer and setting should be maintained such that fault does not carry beyond the affected feeder in case of Overload,3 phase fault, earth fault etc complete all as specified and directed by the Engineer-in-Charge. Note :- The calibration of relay of Microprocessor based three phase relay system required to carried out . Make Siemens 7SR1003, Ashida ADR241A,Micom642 (ii) The calibration of relay of Microprocessor based three phase relay system to be carried out by OEM representative.
Material & labour for two coat of Aluminium Painting MS angle of 132KV MRS Yard such as structures,angle, GO DO etc at Swicthyard complete all as specified and directed by engineer -in- charge
Dismantling wrought iron or mild steel work of any description not otherwise provided for complete all as specified and directed.
S & F MS plates (plain or chequerred) channels, square cut or notched (ordinary and counter sunk) forming holes without any attachment with riveted, bolted or welded attachment of steel conforming to Fe-410-W, Gde E-250, Quality B a in flooring and it supporting members foundation etc all as specified and as directed
.Supply and lay graded stone aggregate of size 40mm graded layed on ground of yard/ two/four pole structure complete all as specified and directed.
Cleaning and preparation of old painted surface of steel tubular pole 11 mtr long (4 pole structure) excluding planting depth complete and painting with one coat of aluminium paint including brackets, clamps, channel etc. and including making alternative black and white strips on pole with synthetic enamel paint and including applying one coat of cement base paint on exposed surface of PCC coping and foundation block complete all as specified and directed by Engineer-in-Charge.
All as per srl item No. 32 here-in-before but (2 pole structure) complete all as specified and directed by Engineer-in-Charge.
Cleaning and preparation of old painted surface of PCC pole 11 mtr long (4 pole structure) excluding planting depth with cement base paint complete and painting with one coat of aluminium paint on brackets, clamps, channel etc. and including making alternative black and white strips on pole with synthetic enamel paint including applying one coat of cement base paint on exposed surface of PCC coping and foundation block complete all as specified and directed by Engineer-in-Charge.
All as per srl item No. 34 here-in-before but (2 pole structure) complete all as specified and directed by Engineer-in-Charge.
Supply Only 11KV Vaccum interrupter bottle 800/630 Amps rating suitable for ABB/Siemens/CG all as directed by Engr-in charge
Supply Only 11KV VCB interrupter housing suitable for ABB/Siemens/CG all as directed by Engr-in charge
M & L in replacement of Rubber gasket double ended flexible type suitable for mounting of glass in HT panel/metering window complete all as specified and directed by Engineer-in-Charge
M & L for including removing of old words on existing VCB panel paste feeder name sticker by using radium letter / No the height of the worked minimum 5 CMs & maximum 30 letters complete all as specified
M & L in replacement of Danger notice plate of 1.6mm thick mild steel sheet of size 25x20 cm, pasting with Sticker in radium red colour with writing 11000 KV, figures and conventional skull and bones size, for HT 11000 volts complete all as specified and directed by Engineer-in-Charge
M&L for preparation of the old painted surfaces of HT VCB panel of any size, any description and in any position including complete removal of old paint either by hand scrubbing or by blow lamps, applying necessary filler coat and scraping as required and applying two coats of grey colour synthetic enamel paint over a coat of zinc chrome primer using spray machine complete all as directed.
S & F of nominal 2.5mm + 10% thick insulated synthetic Mat conforming to IS 15652:2006 alongwith suitable adhesive/chemibound, Pu resin, waterproofing compound and sealing material and similar tape of matching colour and matching design, tapes should be used to maintain aesthetic look of the insulation over the joints and corner as per service recommendation and suitable for Class-B upto 11KV with HT trolley movement all as specified and directed by Engineer-in-Charge.
S & F in replacement of HT feeder pillar box factory made cubical type dust and vermin proof, outdoor type, both side opening of size 110 x 100 x 60cm of CRCA sheet 3 mm thick powder coated, machine pressed front opening in two halves with rubber gasket/bedding, locking arrangement with sliding bolt including aluminium bus bar of size 50 x 10 mm and 80 cm long 3 strips mounted on HT insulators. Each strip should be mounted minimum two insulator and nut bolt, panel shall be mounted on angle iron frame including heat shrinkable sleeve and legs made from angle iron of size 50 x 50 x 6 mm and legs 40 cm long duly spray painted internally and externally with two coats of synthetic enamel paint over a coat of red oxide primer and including grouted in PCC (1:2:4) type B-1 (using 20mm graded stone aggregate) complete incoming/outgoing cable and earth work such as excavation and removal of surplus soil etc complete all as specified and directed.
S & F switch air break gang operated, triple pole, mechanically operated, mounted on insulator and steel frame with operating machanism worked from ground level using heavy duty GI pipe, for current rating 200 Amps, outdoor type (conforming to IS specifications) HT 11 KV, triple pole with fixed contacts of phosphorous and bronze and a set of drop out HT fuse assembly, fuse carrier fitting, 12 insulator type mounted on MS channel operating rod with 7 lever pad lock arrangement complete along with D/O Fuse assembely with insulator and base frame. including disimantling old unserviceable switch air break gang operated device. Make:- JAIPURIA BROTHERs/ Pactil/ BHEL
Material and Labour in replacement Cross arms, bracings, supports, clamps and back plates fabricated from structural steel sections including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape or size as indicated or directed and inclusive of one primer coat, one under coat and one finishing coat of paint complete all as specified and directed Note : The rate of one primer coat, one under coat and one finishing coat of paint is included in this item..
Note:- The contract sum shall be calculated by deducting the amount shown in Credit Schedule attached to this tender from total amount of Schedule 'A'/BOQ.
M/s Kataria Construction Company
M/s NIRMAN BUILDERS
M/s Rohit Construction Co.
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .