Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹8.0 LAccepted-AOC | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹9.5 L+₹94,920 (11.1%)Rejected-Finance | L2 | Rejected-Finance Being L2 | |
| 3 | L3₹9.9 L+₹1.4 L (16.4%)Rejected-Finance | L3 | Rejected-Finance Being L3 | |
| 4 | L4₹10.8 L+₹2.2 L (26.3%)Rejected-Finance | L4 | Rejected-Finance Being L4 | |
| 5 | L5₹10.9 L+₹2.4 L (28.0%)Rejected-Finance 67 KAILASH VIHAR TIWARIPUR BAGIA JAJMAU KANPUR 208010 | KANPUR | KANPUR NAGAR | UTTAR PRADESH | 208010 | L5 | Rejected-Finance Being L5 |
Tender Value
₹12 L
EMD Value
₹24,000
Closing Date
4 Nov 2019, 6:00 pmClosed
GE I R and D Kanpur
GE I R and D Kanpur DMSRDE Complex, GT Road Kanpur 208013
REPAIR, REPLACEMENT, MAINTENANCE OF INDOOR, OUTDOOR FPB, LT PANELS, MCCBS, CABLE JOINTS AND CONNECTED OTHER WORKS AT RAKSHA VIHAR COLONY UNDER GE (I) R and D KANPUR
2019_MES_285934_2
8163/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
RV Colony GE I R and D Kanpur
As Per NIT
8 documents required · 8 mandatory
₹500
Yes
GE I R and D Kanpur
₹24,000
Yes
17 Mar 2020
22 Oct 2019
6 Nov 2019
22 Oct 2019
4 Nov 2019
29 Oct 2019
22 Oct 2019 - 28 Oct 2019
Amount
Excavation in trenches not exceeding 1.5 metre wide and not exceeding 1.5 metre deep in soft/loose soil and getting out for cable complete all as specified and directed.
Returning filling of excavated soil after laying the cable with spreading leveling watering and well ramming in layers not exceeding 25cm thick in loose/soft soil complete all as specified and directed.
Removal of surplus soil/excavated material obtained from ground level to a distance not exceeding 50 metre and depositing where directed at a level not exceeding 1.5 metre above from the starting point complete all as specified and directed.
Supply & spreading local sand obtained from ganga river in trenches for cable cushioning complete all as specified and directed.
Supply & laying /paving of dry well burnt bricks of sub class ‘B’ laid flat of whole brick over the cable after spreading the sand for cable protection complete all as specified and directed.
Supplying and laying un-reinforced precast concrete cable cover, Type 2, flat, size 300mm x 180mm x 40mm over the cable after spreading the sand for cable protection complete all as specified and directed.
M&L for PCC (1:4:8) type D-2 (using 40 mm graded crushed stone aggregate) for foundation base complete all as specified and directed.
M&L for PCC(1:3:6) type C-2 (using 40 mm graded crushed stone aggregate) for foundation of pole and stay assembly complete all as specified and directed.
M&L for PCC (1:2:4) type B-1 (using 20 mm graded crushed stone aggregate) for coping/finishing of pole foundation and plinth protection complete all as specified and directed.
Supply and fixing GI tubing of 100 mm dia bore, light grade conforming to IS 1239 Part-I and ISI marked fixed alongwith pole and embedded in hardstanding / pillar foundation including breaking /cutting PCC/hard standing not exceeding 20 cm girth or as required at site and making good with cement mortar of ratio 1 :3 complete all as specified and directed.
All as per item no 10.00 herein before but 50 mm bore
All as per item no 10.00 herein before but 25 mm bore
Cutting & Chasing required on concrete block /path/tile /floor/ wall not exceeding 20 cm girth to concealed the cable/GI wire and making good to disturbed surface with cement mortar 1:3 including facing / finishing where as required to match with existing surfaces complete all as specified and directed.
Takingout unserviceable cable any type from trenches,pole, road,duct etc including necessary joints(U/S)fittings and pipes etc complete all as specified and directed.
Supply & laying XLPE insulated, PVC sheathed, strip armoured electric cable with aluminium conductor (stranded) working voltage upto 1100 volt of 185.0 Sqmm x 3.5 core as per IS 7098 Pt I in trenches, culvert, through pipe etc including connecting both end with proper size of alluminium lugs duly crimped with die press crimping device and cable gland complete all as specified and directed by Eng-in-charge.
Supply & laying XLPE insulated, PVC sheathed, strip armoured electric cable with aluminium conductor (stranded) working voltage upto 1100 volt of 120.0 Sqmm x 3.5 core as per IS 7098 Pt I in trenches, culvert, through pipe etc including connecting both end with proper size of alluminium lugs duly crimped with die press crimping device and cable gland complete all as specified and directed by Eng-in-charge.
Supply & laying XLPE insulated, PVC sheathed, strip armoured electric cable with aluminium conductor (stranded) working voltage upto 1100 volt of 95.0 Sqmm x 3.5 core as per IS 7098 Pt I in trenches, culvert, through pipe etc including connecting both end with proper size of alluminium lugs duly crimped with die press crimping device and cable gland complete all as specified and directed by Eng-in-charge.
Supply & laying XLPE insulated, PVC sheathed, strip armoured electric cable with aluminium conductor (stranded) working voltage upto 1100 volt of 35.0 Sqmm x 3.5 core as per IS 7098 Pt I in trenches, culvert, through pipe etc including connecting both end with proper size of alluminium lugs duly crimped with die press crimping device and cable gland complete all as specified and directed by Eng-in-charge.
Supply & laying XLPE insulated, PVC sheathed, strip armoured electric cable with aluminium conductor (stranded) working voltage upto 1100 volt of 25 Sqmm x 3.5 core as per IS 7098 Pt I in trenches, culvert, through pipe etc including connecting both end with proper size of alluminium lugs duly crimped with die press crimping device and cable gland complete all as specified and directed by Eng-in-charge.
Dismantling & taking out old u/s worn out 415 Volt, 3 Phase, 4 Wire system, Main LT Panel board ( Indoor Type/outdoor type ) of any size with complete accessories after taking proper shutdown from concern staff and disconnecting all incoming & outgoing cables with due care complete with making the disturbed surface smooth complete all as specified and directed.
Note :- Before construction of panel the proposed drawing will be submited for approval.
INCOMING :
i) MCCB , 4 Pole, 415 VAC, Current rating- 400 Amps, Breaking capacity ( Ics ) - 36 KA, Make:- Indo Asian /Legrand / Seimens/Schneider/Hager as approved by GE (I).- 01 No.
BUS BAR :
i) Electrolytic Aluminium bus bar of of size 30 x 5 mm for all phase conductor & 25 x 5 mm for neutral conductor with heat shrinkable PVC sleeves and be colour coded in Red, Yellow, Blue and Black to identify the three phases and neutral of the system.
ii) Current Transformer of ring type for LT Panel, insulated in Resin casted of CT ratio 200/5-03 Nos
METERING AND INDICATIONS :
i) LED Indicator Lamp of Red, Yellow, Green colour ,Make -L&T ( Esbee ) /Seimens/BCH/Schneider/Vaishno
ii) − Do as above, but in Blue colour for LT Panels ,Make -L&T ( Esbee ) /Seimens/BCH/Schneider/Vaishno
iii) DIgital AC Volt meter , Make: L&T (Risabh) /AE/Secure/Kaycee - 01 Set.
iii) DIgital AC Ammeter , Make: L&T (Risabh) /AE/Secure/Kaycee - 01 Set.
OUT GOINGS :
i) MCCB , 4 Pole, 415 VAC, Current rating- 200 Amps, Breaking capacity ( Ics ) - 36 KA, Make Indo Asian /Legrand / Seimens/Schneider/Hager as approved by GE (I).- 04 No.
ii) MCCB, 4 Pole, 415 VAC, Current rating- 63 Amps, Breaking capacity ( Ics ) - 25 KA, ,Make Indo asian /Standard / Siemens/Schneider(Electric)/Leygrand/HPL/Havells as approved by GE (I)- 06 Nos.
Note :- Before construction of panel the proposed drawing will be submited for approval.
INCOMING :
i) MCCB , 4 Pole, 415 VAC, Current rating- 200 Amps, Breaking capacity ( Ics ) - 36 KA, Make Indo Asian /Legrand / Seimens/Schneider/Hager as approved by GE (I).- 01 No.
BUS BAR :
i) Electrolytic Aluminium bus bar of of size 30 x 5 mm for all phase conductor & 25 x 5 mm for neutral conductor with heat shrinkable PVC sleeves and be colour coded in Red, Yellow, Blue and Black to identify the three phases and neutral of the system.
ii) Current Transformer of ring type for LT Panel, insulated in Resin casted of CT ratio 200/5-03 Nos
METERING AND INDICATIONS :
i) LED Indicator Lamp of Red, Yellow, Green colour ,Make -L&T ( Esbee ) /Seimens/BCH/Schneider/Vaishno
ii) − Do as above, but in Blue colour for LT Panels ,Make -L&T ( Esbee ) /Seimens/BCH/Schneider/Vaishno
iii) DIgital AC Volt meter , Make: L&T (Risabh) /AE/Secure/Kaycee - 01 Set.
iii) DIgital AC Ammeter , Make: L&T (Risabh) /AE/Secure/Kaycee - 01 Set.
OUT GOINGS :
i) MCCB, 4 Pole, 415 VAC, Current rating- 63 Amps, Breaking capacity ( Ics ) - 25 KA, ,Make Indo asian /Standard / Siemens/Schneider(Electric)/Leygrand/HPL/Havells as approved by GE (I)- 07 Nos.
M & L for Earthing complete with galvanised steel earthpipe of 3000mm long and 65mmouter x50mm inner dia laid in ground by drilling in the ground as required with filling the back fill compound complete with all as required and directed with 32x6mm GI strip up to testing point and making the earth pit of PCC as per sample as required at site and testing after completion complete all as specified and directed.Make HP earth or eqvt . Note : Earthing strip upto 7.5 metre length shall be deemed to be included in quoted unit rate.
S & F PCC LT cable route marker of size 800mm x 200mm x 150 mm complete all as specified and directed by GE(I)
Providing the cable fault locating Machine with necessary T&P at site for locating exact pin point of fault along with the length of armourd 1.1/ 6.6 /11 KV XLPE/PILCA insulated LT/HT cable complete all as required and directed at site
M&L for cold shrinkable type cable stright through joint outdoor type suitable for XLPE 185 Sqmm 3.5 to 240 sqmm core cable and testing all as specified and directed with terminate joint and jointing material all as specified directed. Make : Denson/ Raychem/ M - seal as approved by GE (I).
M&L for cold shrinkable type cable end joint outdoor type suitable for XLPE 95 Sqmm 3 core cable 11 KV and testing all as specified and directed with terminate joint and jointing material all as specified and directed. Make : Denson/ Raychem/ M - seal as approved by GE (I).
M&L for cold shrinkable type cable end joint indoor type suitable for XLPE 95 Sqmm 3 core cable 11 KV and testing all as specified and directed with terminate joint and jointing material all as specified and directed. Make : Denson/ Raychem/ M - seal as approved by GE (I).
Supply, fixing and testing in replacement of Old unserviceable /worn out security light fitting by Out Door LED street light fitting 25 W with bracket of suitable size including connection with 3 core sheathed PVC insulated cable not less than 0.5 sqmm not more than 0.50 m long complete all as specified and directed. Make:-Phillips/Bajaj/Havells as approved by GE (I).
Supply and Fix MCCB with continuously adjustableThermal and Adjustable Magnetic Release, Four Pole, 415 VAC, Current rating- 200 Amps, Breaking capacity ( Ics ) - 50 KA,including suitable size aluminium bus bar for connection complete all as specified and directed by GE (I). Make:- Indo Asian /Legrand / Seimens/Schneider/Hager as approved by GE (I).
Supply and Fix MCCB with continuously adjustableThermal and Adjustable Magnetic Release, Four Pole, 415 VAC, Current rating- 63 Amps, Breaking capacity ( Ics ) - 25 KA,including suitable size aluminium bus bar for connection complete all as specified and directed by GE (I). Make:- Indo Asian /Legrand / Seimens/Schneider/Hager as approved by GE (I).
m/s A.A brothers
M/s A S Electrical
M/S S.DAYA SINGH
Ashirwad Contractor and Supplier
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .