Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹29.2 LAdmitted-Finance SR NO 331 2B PLOT NO 43 R H NO 02 BALDEWA RAO BUNGLOW NEWA NMC WATER TANK PATHARDI SHIVAR NASHIK 422 009 INDEX NO E 84CWE AF LOHEGAON PUNE | NASHIK | MAHARASHTRA | 422009 | ₹29.2 L | L1 | Admitted-Finance |
| 2 | L2₹29.5 L+₹26,639 (0.91%)Admitted-Finance 154 HANUMAN MANDIR DIKSHI TAL NIPHAD DIST NASHIK 422 302 | NASHIK | MAHARASHTRA | 422302 | ₹29.5 L+₹26,639 (0.91%) | L2 | Admitted-Finance |
| 3 | L3₹30.5 L+₹1.3 L (4.52%)Admitted-Finance | ₹30.5 L+₹1.3 L (4.52%) | L3 | Admitted-Finance |
| 4 | L4₹33.7 L+₹4.5 L (15.3%)Admitted-Finance | ₹33.7 L+₹4.5 L (15.3%) | L4 | Admitted-Finance |
| 5 | L5₹35.6 L+₹6.4 L (21.9%)Admitted-Finance | ₹35.6 L+₹6.4 L (21.9%) | L5 | Admitted-Finance |
| Sl No | Description | Qty | Unit | MAHIMA CONSTRUCTION L2 | MUKTI ENTERPRISES L3 | sapana enterprises L6 | UNITED ENTERPRISES L5 | RAVI ELECTRICALS L4 | Shree Sai Samarth Enterprises L1 | ANIKET ENGINEERING L7 |
|---|---|---|---|---|---|---|---|---|---|---|
| 1.00 | Comprehensive maintence, testing/Servicing and repair including preventive and periodical maint with renewals and replacement of defective parts of all existing fire protection and fire fighting system complete consisting of main fire control panels of 2x5 HP Jokey pump, 2x50 HP C/F pumps and 1xEngine pump 50 HP by necessary decarbonising, cleaning, tightening & 100 % servicing of all loose contact , sub panels, smoke/heat detector/response indicator Electric driven pump 50 HP, Diesel driven pump with 50 HP, Jockey pump, pressure switch, presure vessels, fire hydrents, hose reels, canvas hose pipes, gunmetal valves, shut of nozzels, sprinklers, Fire Pump Control Panel etc with control panel, starters and to keep fire fighting system and fire alarm system auto run mode on variation in pressure to make 100% serviceability of the complete system installed at ARTW Hangar every month during first or Last week as directed. | 9 | Per month | 6,030 ₹54,270 | 14,500 ₹1,30,500 | 4,500 ₹40,500 Lowest | 12,000 ₹1,08,000 | 9,000 ₹81,000 | 12,000 ₹1,08,000 | 13,000 ₹1,17,000 |
| 2.00 | Comprehensive maintence, testing/Servicing and repair including preventive and periodical maint with renewals and replacement of defective parts of all existing fire Alarm System complete consisting of main fire CMS Panel ,Hooter control panel, Fire alarm repeatre panel, IOT fire alarm Main panel, manual call point, fire beam detector, smoke cum heat detector, hooter, UV flame detector etc complete make 100% serviceability of the complete checking, cleaning of fire detector by removing dust or dirt, cleaning of heavy greasy deposit if any, checking the connection of battaries, specific gravity of electrolyte, the alarm function control panel and indicating eqpts be checked by the opration of trigger device in each zone as described the system every month during first or Last week as directed at locations:-
(i) ARTW Hangars
(ii) P-257 New MF Hangar | 9 | Per month | 6,030 ₹54,270 Lowest | 12,000 ₹1,08,000 | 6,500 ₹58,500 | 9,000 ₹81,000 | 7,500 ₹67,500 | 10,000 ₹90,000 | 11,000 ₹99,000 |
| 2.10Notes for item No. 1 & 2:- (a) Cost of new components shall be paid for separately under relevant item of shchedule 'A' (b) Contractor's rep will visit minimum once in a month to every panel and take servicibility certificate duly signed by the users and MES Rep. Additional visit as and when required will not be paid as extra. (c) Cost of minor spares if any costing not more than Rs 1,000.00 per month in total deemed to be included in the quoted rate. (d) Payment will be processed on production of servicibilty certififace only and a panel recovery @ double the quoted rate will be charged for non carrying out of monthly serviceability check (e) The rate quoted above shall be inclusive of minimum material as mentioned above and labour for unserviceable items, replacement of unserviceable eqpts and any other item not mentioned in the schedule but required to be replaced to make the Fire Fighting system serviceable complete all as directed. (f) The bidder are requested to inspect the FF system to ascertain the servicebility of all the equipments if any items required to be repaired or replaced are deemed to be included in the quoted rate. | ||||||||||
| 2.20(g) The rates quoted shall be inclusive T&P required for carrying repairs and stationery for maintaining records such as daily, fortnightly, monthly, quarterly and yearly maintenence, complaints book etc all as described. (h) Normally maintaenance shall be carried out in day time but in case of emergency /breakdown, it should be attenend at odd hrs/night times and additional manpower if required will be arranged by the contractor without any extra cost & rates. (j) The contractor shall provide the service of trained personnel, ITI qualified mechanic and oprator with 3 yrs exeperience & helper shall 12th pass and supervisor shall be minimum diploma certificate holder with 3 yrs exeperience in the trade. (k) The contractor shall carry out daily routine checking of the complete system and rectify the minor /major defects noticed immediately. One seprate register to be maintained as complaint register received from department /user's signature shall be obtained after rectifying defects each time. If complaints are not attended within 24 hours, following penalties will be imposed and deducted from payment to the contractors. Contractor quoted rates shall be deemed to include the cost of daily routine checking of complete system, rectification of defects and cleaning of installation from inside and outside with cleaning materials. Penalty of Rs 500/- shall be imposed for not attending the complaint and keep it pending beyond 24 hours per complaint per day. | ||||||||||
| 2.30(l) All consumable & maint material such as oil, lubricants, grease, thimbles etc will be deemed to be included in the rate quoted against above schedule. (m) The contractor will use only genuine/original new parts as approved by original equipment manufacturer during repair and old unserviceable materials should be kept at site till verification and proper register to be maintained all as specified and directed. (n) In case any rewinding of motor is required cost of disconnection transportation and reassembling cost shall be deemed to include the quoted rate. Other items such as copper winding, wire bushes bearing etc shal be measured and paid seperately under relevent item of Sch A. | ||||||||||
| 3.00 | S&F in repair CP Fire fighting RRL hose pipe of 63 mm dia 15 m long alongwith GM male and female couppling duly bound with GI wire conforming to IS 8423 with ISI marked & approved, all as specified and as directed. | 24 | Each | 6,300 ₹1,51,200 | 6,000 ₹1,44,000 | 5,500 ₹1,32,000 Lowest | 6,800 ₹1,63,200 | 6,500 ₹1,56,000 | 8,000 ₹1,92,000 | 6,000 ₹1,44,000 |
| 4.00 | S&F in repair fire hose cabinet of size 1000x1000x300 mm out door type with pedestal & grouted with suitable PCC foundation, fabricated from 16 gauge, MS sheet with double leaf glazed shutters (glazed with 4 mm thick float glass) the cabinet shall have powder quoted finish both internally & externally in signaled shade with "FIRE HOSE" written in bold letters on front & side faces suitable to house, two lengths canvas hoses 30 m long, 63 mm dia along with GM male & famale coupling duly bound with GI wire conforming to IS 8423 with ISI mark approved with and including nozzle, one branch pipe, one fireman axe & hose reel of suitable size etc coplete all as specified & directed. | 6 | Each | 12,000 ₹72,000 | 7,000 ₹42,000 | 4,000 ₹24,000 Lowest | 8,500 ₹51,000 | 12,000 ₹72,000 | 9,500 ₹57,000 | 16,000 ₹96,000 |
| 5.00 | S&F in repair MS Pipe stand post of 80 mm dia 1.5m height with flange gasket and nut bolts all as specified and as directed. | 4 | Each | 3,600 ₹14,400 | 4,000 ₹16,000 | 4,000 ₹16,000 | 4,700 ₹18,800 | 4,500 ₹18,000 | 2,200 ₹8,800 Lowest | 6,000 ₹24,000 |
| 6.00 | S&F in repair intel 4 way for fire brigade to the main pipe ring with butterfly valve of 150 mm dia and NRV of 150 mm dia size with instaneous manifold all as specified and as directed. | 2 | Each | 8,100 ₹16,200 | 11,500 ₹23,000 | 30,000 ₹60,000 | 8,500 ₹17,000 | 10,000 ₹20,000 | 15,000 ₹30,000 | 8,000 ₹16,000 Lowest |
| 7.00 | S&F in repair 63 mm dia gun metal single outlet hydrant valve (ISI marked) fitted with necessary accessories complete, all as specified and as directed. | 4 | Each | 6,500 ₹26,000 | 2,500 ₹10,000 Lowest | 7,500 ₹30,000 | 2,500 ₹10,000 Lowest | 2,800 ₹11,200 | 4,000 ₹16,000 | 4,000 ₹16,000 |
Tender Value
₹40 L
EMD Value
₹80,000
Closing Date
31 Jul 2026, 6:00 pmClosed
Garrison Engineer Nasik Road
Garrison Engineer Nasik Road AOP Complex Near AOP Gate PO Gandhinagar Nasik 422006
As per tender doucuments
2026_MES_776207_1
GE/NRC/8814/E8
Open Tender
Civil Works
Item Rate
180 days
Garrison Engineer Nasik Road
As per NIT
8 documents required · 8 mandatory
₹500
Yes
Garrison Engineer Nasik Road
₹80,000
Yes
8 Aug 2026
3 Jul 2026
3 Aug 2026
3 Jul 2026
31 Jul 2026
17 Jul 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Comprehensive maintence, testing/Servicing and repair including preventive and periodical maint with renewals and replacement of defective parts of all existing fire protection and fire fighting system complete consisting of main fire control panels of 2x5 HP Jokey pump, 2x50 HP C/F pumps and 1xEngine pump 50 HP by necessary decarbonising, cleaning, tightening & 100 % servicing of all loose contact , sub panels, smoke/heat detector/response indicator Electric driven pump 50 HP, Diesel driven pump with 50 HP, Jockey pump, pressure switch, presure vessels, fire hydrents, hose reels, canvas hose pipes, gunmetal valves, shut of nozzels, sprinklers, Fire Pump Control Panel etc with control panel, starters and to keep fire fighting system and fire alarm system auto run mode on variation in pressure to make 100% serviceability of the complete system installed at ARTW Hangar every month during first or Last week as directed. | 9 | Per month | - | - |
| 2 | Comprehensive maintence, testing/Servicing and repair including preventive and periodical maint with renewals and replacement of defective parts of all existing fire Alarm System complete consisting of main fire CMS Panel ,Hooter control panel, Fire alarm repeatre panel, IOT fire alarm Main panel, manual call point, fire beam detector, smoke cum heat detector, hooter, UV flame detector etc complete make 100% serviceability of the complete checking, cleaning of fire detector by removing dust or dirt, cleaning of heavy greasy deposit if any, checking the connection of battaries, specific gravity of electrolyte, the alarm function control panel and indicating eqpts be checked by the opration of trigger device in each zone as described the system every month during first or Last week as directed at locations:-
(i) ARTW Hangars
(ii) P-257 New MF Hangar | 9 | Per month | - | - |
| 2.2 | (g) The rates quoted shall be inclusive T&P required for carrying repairs and stationery for maintaining records such as daily, fortnightly, monthly, quarterly and yearly maintenence, complaints book etc all as described.
(h) Normally maintaenance shall be carried out in day time but in case of emergency /breakdown, it should be attenend at odd hrs/night times and additional manpower if required will be arranged by the contractor without any extra cost & rates.
(j) The contractor shall provide the service of trained personnel, ITI qualified mechanic and oprator with 3 yrs exeperience & helper shall 12th pass and supervisor shall be minimum diploma certificate holder with 3 yrs exeperience in the trade.
(k) The contractor shall carry out daily routine checking of the complete system and rectify the minor /major defects noticed immediately. One seprate register to be maintained as complaint register received from department /user's signature shall be obtained after rectifying defects each time. If complaints are not attended within 24 hours, following penalties will be imposed and deducted from payment to the contractors. Contractor quoted rates shall be deemed to include the cost of daily routine checking of complete system, rectification of defects and cleaning of installation from inside and outside with cleaning materials. Penalty of Rs 500/- shall be imposed for not attending the complaint and keep it pending beyond 24 hours per complaint per day. | - | - | - | - |
| 2.3 | (l) All consumable & maint material such as oil, lubricants, grease, thimbles etc will be deemed to be included in the rate quoted against above schedule.
(m) The contractor will use only genuine/original new parts as approved by original equipment manufacturer during repair and old unserviceable materials should be kept at site till verification and proper register to be maintained all as specified and directed.
(n) In case any rewinding of motor is required cost of disconnection transportation and reassembling cost shall be deemed to include the quoted rate. Other items such as copper winding, wire bushes bearing etc shal be measured and paid seperately under relevent item of Sch A. | - | - | - | - |
| 3 | S&F in repair CP Fire fighting RRL hose pipe of 63 mm dia 15 m long alongwith GM male and female couppling duly bound with GI wire conforming to IS 8423 with ISI marked & approved, all as specified and as directed. | 24 | Each | - | - |
| 4 | S&F in repair fire hose cabinet of size 1000x1000x300 mm out door type with pedestal & grouted with suitable PCC foundation, fabricated from 16 gauge, MS sheet with double leaf glazed shutters (glazed with 4 mm thick float glass) the cabinet shall have powder quoted finish both internally & externally in signaled shade with "FIRE HOSE" written in bold letters on front & side faces suitable to house, two lengths canvas hoses 30 m long, 63 mm dia along with GM male & famale coupling duly bound with GI wire conforming to IS 8423 with ISI mark approved with and including nozzle, one branch pipe, one fireman axe & hose reel of suitable size etc coplete all as specified & directed. | 6 | Each | - | - |
| 5 | S&F in repair MS Pipe stand post of 80 mm dia 1.5m height with flange gasket and nut bolts all as specified and as directed. | 4 | Each | - | - |
| 6 | S&F in repair intel 4 way for fire brigade to the main pipe ring with butterfly valve of 150 mm dia and NRV of 150 mm dia size with instaneous manifold all as specified and as directed. | 2 | Each | - | - |
| 7 | S&F in repair 63 mm dia gun metal single outlet hydrant valve (ISI marked) fitted with necessary accessories complete, all as specified and as directed. | 4 | Each | - | - |
| 8 | S&F in repair wall mounting, swinging hose reel drum as per IS 884 and fitted with 25 mm dia 30 m long high pressure polyproplene (Polyhose) pipe high pressure as per IS : 444 (Type III) Gun metal chrome plated nozzle and 25 mm dia gun metal gate valve on the inlet pipe with necessary MS Bracket for holding Hose reel drum fitted in position with wall fasteners etc as approved complete all as specified & directed. | 4 | Each | - | - |
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 0.05 MB
BOQ_869202.xls
BOQ • 0.38 MB
8814SOC.pdf
Additional Documents • 0.01 MB
8814PS.pdf
Tender Documents • 0.23 MB
8814Amendment.pdf
PDF • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .