Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹1.6 LAccepted-Finance | 1 | Accepted-Finance Being L1 | |
| 2 | 2₹1.6 L+₹1,825 (1.14%)Accepted-Finance | 2 | Accepted-Finance Being L2 | |
| 3 | 3₹1.7 L+₹5,465 (3.42%)Accepted-Finance RANGAT MIDDLE ANDAMAN | NORTH AND MIDDLE ANDAMAN | ANDAMAN AND NICOBAR ISLANDS | 744201 | 3 | Accepted-Finance Being L3 | |
| 4 | 4₹2.1 L+₹54,265 (34.0%)Accepted-Finance | 4 | Accepted-Finance Being L4 | |
| 5 | Not Admitted-Fee/PreQual/Technical | - | Not Admitted-Fee/PreQual/Technical Not Complied with technical specification |
Tender Value
₹1.6 L
EMD Value
₹3,245
Closing Date
12 Sept 2023, 3:00 pmClosed
Executive Engineer
Executive Engineer, CD-I, APWD, Rangat
Replacement of fender and minor repair works at RCC Jetty at Shyamkund Bakultala under CD-I, Rangat. SW-Renovation of IEI and EEI to RCC Jetty constructed by ALHW at Shyamkund Bakultala, Middle Andaman
2023_APWD_11458_1
13/DB/EandM/CD-I/RGT/2023-24
Open Tender
Electrical Works
Item Rate
30 days
Bakultala
Please refer Tender documents.
6 documents required · 6 mandatory
₹0
₹3,245
4 Oct 2023
2 Sept 2023
12 Sept 2023
2 Sept 2023
12 Sept 2023
2 Sept 2023
Amount
Wiring for light/fan point/exhaust fan point/call bell point with 1.5sqmm FRLS PVC insulated copper conductor single core cable in surface/recessed medium class PVC conduit with piano type switch, phenolic laminated sheet, suitable size M.S box and earthing the point with 1.5 Sqmm FRLS PVC insulated copper conductor single core cable etc. as required.
Group C
Wiring for circuit/ submain wiring alongwith earth with wire the following sizes of FR PVC insulated copper conductor single core cable in surface/recessed medium class PVC conduit as required.
2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire
2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire
2 X 6 Sqmm + 1 X 6 sqmm earth wire
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/recessed steel/ PVC conduit as required
2 x 1.5 sq. mm
Supplying and fixing 3 pin, 5 amp. ceiling rose on the existing junction box/ wooden block including connection etc as required
Supplying of Surface mounted LED Batten Luminaires with Lamp type 20W LED 6000K, Make;- Havells, E-LITE LED PRIDE PLUS or its equivalent as approved by Engineer - in - Charge.
Installation, testing and commisioning of pre-wired, fluorescent fitting / compact fluorescent fitting of all types, complete with all accessories and tube etc. directly on celling/ wall, including connection with 1.5 sq. mm FR PVC insulated, copper conductor, single core cable and earthing etc. as required.
Supplying of Surface mounted 10W LED bulkhead fitting back lit luminaire, Make;- Havells, HEXA 10W-IP66 , Cat No. HEXAFT10WLED857SSYMBOPC or its equivalent as approved by Engineer - in - Charge.
Installation ,Testing, Commissioning of wall bracket /ceiling fittings of all sizes and shapes containing upto two GLS/CFL/LED lamps per fitting, complete with all accessories including connections etc. as required.
Supplying & fixing of LED 72 W Street Light made up of pressure die cast aluminium housing with high power LEDs and lens embedded PC cover hjaving top opening having IP66 protection on existing pole Make: Havells, Model ENDURA OMNIPLUS, Cat No. ENDURAOMNIPLUSSL72WLED757SASYTOPC or its equivalent as approved by Engineer - in Charge i/c connections etc. as required.
Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)
6 way , Double door
Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, 'C' curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as reqd.
Single pole
Supplying and fixing following rating, double pole, 240 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.
Supplying of following size ISI marked PVC insulated and PVC sheathed/ XLPE (heavy duty) Armoured 1.1 KV grade Aluminium conductor cable conforming to IS:7098 (Part - I )1988.
3 core x 16 sqmm
Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc.direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc. , complete as required
40 mm dia (40 mm OD & 32mm ID)
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required.
Upto 35 sq. mm
Supplying & fixing of SMC box of Size 230 x 170 x 105mm (Outer dia), 4 way connector & 6 Amps MCB with clamping arrangement etc. as required as per direction of Engineer - in - Charge.
Suppying, Installation Testing and Commissioning of L.T out door feeder box of minimum size 0.80 Mx 0.60 M x 0.4 M with 4 legs made out of MS angle and GI plate having both side opening and locking arrangement and compartment to house the following accessories i,e. 2 Nos.63A/415V porcelain fuse carrier and base, SPN Aluminium Bus Bar of size 40mm x 6mm, 400mm length, space for 1-phase Energy Meter i/c making foundation and plateform of size 0.80 M x 0.60 M of 0.3M thickness, inter earthing, painting of 1 coat of primer and 2 coats of finishing paints with interconnection setc. as required.
Providing, laying and fixing following dia G.I. pipe (medium class) in ground complete with G.I. fittings including trenching (75 cm deep)and re-filling etc as required
50mm dia
Supplying , Installation, Testing and Commissioning of ASHLOK Make SEE brand safe earthing electrode type-19, 50mm dia, length 2 Mtr (short time current- 52.6rms for 1 sec, peak - 125.6) with back fill compound including providing masonary enclosure with cover plate having locking arrangement etc. as required.
Providing and laying earth connection from earth electrode with 4.00 mm dia copper wire in 15 mm dia G.I. pipe from earth electrode including connection with copper thimble excavation and re-filling as required
Providing and fixing 4.00mm dia copper wire on surface or recess for loop earthing as required.
M/s G K Construction
GYANA SHANMUGAM
SARAVANA TRADING COMPANY
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .