| 1.00 | M & L for Disconnecting and Servicing of Transformer of rating 1000 KVA transformer,11 KV / 433 V Dry type Transformer with OLTC Service (Air cooled), disconnecting all Internal Connections of HT/LT Side for Periodical Maintenance, air blowering, Nut bolt tightness, Core Clamp Tightening, Cleaning with CTC HT and LT Insulator etc. and then after asembling to all complete all as specified and as directed.
Protection Check :- WTI Alarm, WTI Trip and Door Open Trip Check.
Testing of Transformer :-
➢ IR Value
➢ Voltage Ratio
➢ Magnetic current balance
➢ Magnetic Voltage balance
➢ Continuity Test
➢ Lamp series Test
➢ High Voltage Test | 1 | Each Job | 5,555 ₹5,555 | 5,000 ₹5,000 Lowest | 15,000 ₹15,000 |
| 2.00 | Supply, Installation, testing & Commissioning in repair of transformer protection relay Range 0-300 degree Centigrade Auxiliary supply 220V AC Working for WTI Alarm and WTI Trip Transformer Protection and its control wiring connection.complete all as specified and as directed. | 1 | Each | 22,555 ₹22,555 | 21,000 ₹21,000 | 3,900 ₹3,900 Lowest |
| 3.00 | M & L for Disconnecting and Servicing LT ACB of capacity 800 Amps to 2000 Amps by disconnecting from the busbar and cleaning with air blowering CRC, CTC, Grease, B nut-bolt tightening replacing all unserviceable parts of finger contact with male female set and wiring with new copper conductor cable of 2.5 sq mm.Replacing the U/S mechanical spring system , fixed and moving contacts, replacement of bearing of spring charge motor. complete all as specified and directed.
Note : Replacement of spares such as Selector switch, fixed Arc contact, moving Aec contact, Auxiliaey, motor Mechanism, control Fuses HRC type paid seperetely and all the items mentioned below are tentative and may vary in specification and quantity during execution | 1 | Each Job | 3,455 ₹3,455 | 3,000 ₹3,000 Lowest | 3,900 ₹3,900 |
| 4.00 | S&F in repair of Fixed Arc Contact- 3 pole suitable for existing ACB Panel as per existing make complete all as specified and directed. | 1 | Each | 2,955 ₹2,955 | 2,600 ₹2,600 Lowest | 3,900 ₹3,900 |
| 5.00 | S&F in repair of Moving Arc Contact- 3 pole suitable for existing ACB Panel as per existing make complete all as specified and directed. | 1 | Each | 3,555 ₹3,555 | 3,500 ₹3,500 Lowest | 5,900 ₹5,900 |
| 6.00 | S&F in repair of Auxiliary contact 4 No+ 4 NC suitable for existing ACB Panel as per existing make complete all as specified and directed. | 1 | Each | 1,655 ₹1,655 | 1,400 ₹1,400 Lowest | 3,900 ₹3,900 |
| 7.00 | S&F in repair of Motor Mechanism for 800 Amps ACB suitable for existing ACB Panel as per existing make complete all as specified and directed. | 1 | Each | 10,555 ₹10,555 | 9,900 ₹9,900 | 3,900 ₹3,900 Lowest |
| 8.00 | S&F in repair of Control Fuses HRC type 2 to 10 Amps suitable for existing ACB Panel as per existing make complete all as specified and directed. | 1 | Each | 165 ₹165 | 140 ₹140 Lowest | 900 ₹900 |
| 9.00 | M & L for servicing of IDMT Relays, Calibration of Secondary Injection Test and Primary Injection Test with High Voltage, CT Ratio Test, CT Polarity Test, CT continuity test complete all as specified and directed | 4 | Each Job | 955 ₹3,820 | 900 ₹3,600 Lowest | 3,500 ₹14,000 |
| 10.00 | M & L for Disconnecting and Servicing of 11 KV 630-800 Amp VCB Panel with CT Chamber, PT Chamber and Busbar Chamber Cleaning, Airblowering clean and nut-bolt tightening,and reassembling, testing and commissioning etc. of any make as required to complete all as specified and directed.
Note : Replacement of spares such as space heater, CT ratio , LED indicator, spout insulator, Bus Bar insulator, breaker charging motor,Trip coil, Release coil paid seperetely and all the items mentioned below are tentative and may vary in specification and quantity during execution | 2 | Each Job | 2,855 ₹5,710 | 2,600 ₹5,200 Lowest | 8,500 ₹17,000 |
Tender Value
₹5 L
EMD Value
₹10,000
Closing Date
20 Oct 2025, 6:00 pmClosed
CWE NEW DELHI
HQ CWE NEW DELHI
REPAIR MAINT OF TRANSFORMER HT AND LT SWITCH GEARS ALONGWITH CONNECTED ACCESSORIES AT HQ IDS UNDER GE NEW DELHI
2025_MES_727224_2
CWE-ND/28/2025-26
Open Tender
Civil Works - Others
Item Rate
120 days
DELHI CANTT
Please refer Tender documents.
9 documents required · 9 mandatory
₹300
GE NEW DELHI
₹10,000
5 Dec 2025
30 Sept 2025
22 Oct 2025
30 Sept 2025
20 Oct 2025
8 Oct 2025
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.62 MB
retender28.pdf
Tender Documents • 1.60 MB
BOQ_821041.xls
BOQ • 0.32 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .