| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹24.2 LAccepted-AOC | L1 | Accepted-AOC LOWEST BIDDER | |
| 2 | L2₹24.2 L+₹2,519 (0.10%)Rejected-Finance | L2 | Rejected-Finance HIGHER BIDDER | |
| 3 | L3₹25.5 L+₹1.2 L (5.11%)Rejected-Finance 1 9 | PRAYAGRAJ | UTTAR PRADESH | 211001 | L3 | Rejected-Finance HIGHER BIDDER | |
| 4 | Rejected-Technical | - | Rejected-Technical REJECTED DUE TO NOT ENLISTED IN REQUIRED CATEGORY | |
| 5 | Rejected-Technical | - | Rejected-Technical REJECTED DUE TO SUBLET OF CONTRACT AND NON SUBMISSION OF DOCUMENTS TO CHECK THE CRITERIA OF E CLASS AND CATEGORY A I AND B I AS PER NIT |
Tender Value
₹24.3 L
EMD Value
₹48,540
Closing Date
2 May 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
VIVEK TANENIA
GARRISON ENGINEER (CENTRAL) KOLKATA T37 NAPIER ROAD HASTING KOLKATA 700022
PROVN OF PARKING SHED FOR INTEGRATED MESS COMPLEX AND PROVN OF AC SOCKT IN B BLOCK AND C BLOCK AT AIR FORCE CAMP BALLYGUNGE UNDER GE (C) KOLKATA
2023_MES_579653_2
8552/E8
Open Tender
Miscellaneous Works
Item Rate
180 days
KOLKATA
AS PER TENDER DOCUMENTS
9 documents required · 9 mandatory
₹500
GE (C) KOLKATA
₹48,540
Yes
13 Jun 2023
11 Apr 2023
3 May 2023
11 Apr 2023
2 May 2023
20 Apr 2023
11 Apr 2023 - 19 Apr 2023
Amount
Excavation in trenches n.exc 1.5 m wide and n.exc 1.5 m in depth for foundation, etc and getting out in soft/loose soil for laying of water supply pipe line /under ground cable complete all as specified and directed.
Excavating in post holes (or similar holes) each n exc 0.5 cum, getting out, returning, filling in and ramming earth or broken rubble mixed with earth round, in layers not exceeding 25 cm in soft/loose soil complete all as specified and as directed.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 Cm as in soft/loose soil complete all as specified and directed.
Removing excavated material ( soils of any type) not exc. 50 m and depositing where directed at a level not exc 1.5 m above the starting point complete all as specified and directed.
M&L Cement Concrete type D2 (1:4:8) using 40mm graded aggregate 150mm thick in Sub-bases, finishing concrete surfaces fair and even, complete all as specified and as directed.
M&L Plain Cement Concrete type C2 (1:3:6) using 40 mm graded aggregate) in Foundation, Filling and Mass Concrete, complete all as specified and as directed.
S&F plates (Plain or chequered) channels, square cut or notched (ordinary and counter sunk) forming holes, without any attachment conforming toFe-410-W (Gde-E- 250 quality -B) complete all as speci-fied and as directed.
M&L Mild Steel Screw Bolts (machine made) 16mm to 20mm diameter of neck and length of bolt exc 15 cm and not exc. 22.5 cm with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut, complete all as specified and as directed.
M&L Steel Work in Tubular /hollow section as in Trusses and post including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to IS-4923 grade YSt.-240 complete all as specified and as directed.
S&F Pre-painted galvalume aluminium zinc coating GI based corrugated/semi corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screw complete all as specified and directed.
M&L Prepolished rubber moulded Coloured Cement Concrete designers Chequered Tiles 326 x 326x 25 mm thick, set and jointed in neat cement slurry and pointed in coloured cement to match the colour of tiles complete including 15 mm screed bed in CM (1:6) of thickness complete all as directed.
M&L Preparing new Steel or Iron Surfaces of any description, over 10 Cm width or girth and applying Two Coats of Synthetic Enamel Paint (First quality) over a coat of Red Oxide/ Zinc Chrome Primer, complete all as specified and as directed.
M&L for Point wiring with PVC insulated and unsheathed FRLSH cable single core multistranded copper conductor 1.5 sqmm size, 1100 volts grade cable conforming to IS - 694 1990 drawn through and including PVC concealed conduit 20mm dia medium duty with all accessories including fabricated 1.6 mm thick MS terminal boxes fixed flush with wall surface with 3 mm thick plastic masonite laminated sheet top cover fixed with cadmium screw for mounting switches, sockets, regulator etc including 1.5 sq mm FRLSH stranded PVC insulated and unsheathed copper conductor earth continuity conductor to common earth and connecting to earth dolly all as specified for one light or fan point controlled by one switch single pole one way for light/ ceiling fan/ exhaust fan/call bell point/ Switch socket outlet 5 amps complete all as specified and as directed. Note: (i) Red coloured cable shall be used for live connection, black coloured cable shall be used for neutral connection and green coloured cable shall be used for earthing. Separate cable for earthing and neutral to be used for each individual circuit from the distribution board. (ii) Cutting Chases pinning shall be measured and paid separately under relevant item of Sch A
M&L Point wiring with PVC insulated and unsheathed FRLSH cable single core multistranded copper conductor 6.0 sqmm size, 1100 volts grade cable conforming to IS - 694 1990 drawn through and including PVC casing caping of suitable size with all accessories including fabricated MS terminal boxes fixed flush with wall surface with 3 mm thick plastic masonite laminated sheet top cover fixed with cadmium screw for mounting AC sockets, regulator etc including 6.0 sq mm FRLSH stranded PVC insulated and unsheathed copper conductor earth continuity conductor to common earth and connecting to earth dolly for AC socket outlet independent point controlled by MCB SPN/SP complete all as specified and as directed. Note: Red coloured cable shall be used for live connection, black coloured cable shall be used for neutral connection and green coloured cable shall be used for earthing. Separate cable for earthing and neutral to be used for each individual circuit from the distribution board..
S&F Switch piano, flush type, SP, one way, 5/6 Amps 230/240 Volts, white/ivory finish complete all as specified and directed.
S&F Ceiling rose , PVC/ polycarbonate ,65x50 three terminals 240 volts complete all as specified and as directed.
S&F Surface and wall mounted LED batten 4feets with 1x20W, AC decorative luminaries with and including electronic driver and 1x20W LED lamp,pre wired including necessary electric connection copper flexible PVC cable of 0.5 sqmm 3 core not more than 1m in length from ceiling rose to light fittings including taking down unserviceable fittings complete all as specified and directed. Make: Magik Cat No. BWPP020C or Philips Cat no. BN021CLED22SPSUCWGR or equivalent in Bajaj/Havells
M&L Sub main wiring with 2 runs of single core FRLSH type PVC insulated unsheathed stranded copper conductor of size 4.0 Sqmm and one run of PVC insulated unsheathed multistrand copper conductor FRLSH type of size 4.0 Sqmm as earth lead drawn pvc casing caping suitable size including all fittings complete all as specified and as directed. Note:- Two runs of 4 Sqmm conductor as main wire and one run of 4 Sqmm conductor as earth wire with one run of PVC casing caping shall be measured as one unit.
M&L Sub main wiring with 2 runs of single core FRLSH type PVC insulated unsheathed stranded copper conductor of size 6.0 Sqmm and one run of PVC insulated unsheathed multistrand copper conductor FRLSH type of size 6.0 Sqmm as earth lead drawn pvc casing caping suitable size including all fittings complete all as specified and as directed. Note:- Two runs of 6 Sqmm conductor as main wire and one run of 6 Sqmm conductor as earth wire with one run of PVC casing caping shall be measured as one unit.
M&L Sub main wiring with 2 runs of single core FRLSH type PVC insulated unsheathed stranded copper conductor of size 10.0 Sqmm and one run of PVC insulated unsheathed multistrand copper conductor FRLSH type of size 10.0 Sqmm as earth lead drawn pvc casing caping suitable size including all fittings complete all as specified and as directed. Note:- Two runs of 10.0 Sqmm conductor as main wire and one run of 10.0 Sqmm conductor as earth wire with one run of PVC casing caping shall be measured as one unit.
S&F MCB SPN DB made up with sheet metal double door, phosphorised, power coated, neutral link, earth bar and din rail, 4 way with 200 amps rated bus bar, 240 volts complete all as specified and as directed. Make:- L&T/Schneider/ ABB/Legrand/ C&S
S&F MCB SPN DB made up with sheet metal double door, phosphorised, power coated, neutral link, earth bar and din rail, 8 way with 200 amps rated bus bar, 240 volts complete all as specified and as directed. Make:- L&T/Schneider/ ABB/Legrand/ / C&S
S&F MCB TPN DB double door made up with sheet metal, phosphorised, power coated, neutral link, earth bar and din rail, 8 way TPN with 200 amps rated bus bar, 415 volts complete all as specified and as directed. Make:- L&T /Schneider/ ABB/Legrand/ C&S
S&F MCB SPN 32 Amps, , 240 Volts , 'B' curve breaking capacity 10 kA complete all as specified and as directed. Make:- Schneider/ ABB/Legrand/ L&T/ C&S
S&F MCB SPN 32 Amps, , 240 Volts , 'C' curve breaking capacity 10 kA complete all as specified and as directed. Make:- Schneider/ ABB/Legrand/ L&T/ C&S
S&F MCB 6 to 32 Amps, SP, 240 Volts , 'B' curve breaking capacity 10 kA complete all as specified and as directed. Make:- Schneider/ ABB/Legrand/ L&T/ C&S
S&F MCB TP 63 amps 240 volts 'B' curve breaking capacity 10 kA complete all as specified and as directed. Make:- Schneider/ ABB/Legrand/ L&T/ C&S
S&F AC starter unit consisting of one 25 Amp capacity starter, one 240 V 25 Amps 10 KA SPN MCB, one 25 Amps socket and one 25 Amps plug top prewired including taking down of old UNSV one complete as specified all as directed by Engr-in-charge. Make : Havell's Cat No-DHDUCDP0253016-25 or equivalent in North West / Anchor / Legrand
Supply and laying dry coarse sand as in cushioning of under ground electric cable in trenches, laid to a uniform thickness of 23 Cm (15 Cm under the cable & 8 Cm over the cable) and gently punned down to 18 Cm thickness complete all as specified and as directed by the Engr-in-Charge. Note:- Thickness after punning down shall be measured for payment.
Supply and laying in trenches Bricks, sub class 'B' over burnt (kiln burnt) old size bricks, laid flat dry with width of the bricks laid to the axis of the cable for protection of cable complete all as specified and as directed by the Engr-in-Charge.
M&L Cutting existing road / path etc for taking out cable and protection pipe and making good the disturbed surfaces with cement concrete type C2 ( 1:3:6, using 40mm graded crushed stone aggregates) of suitable depth complete all specified and as directed by Engineer-in-Charge.
Supply and laying XLPE insulated PVC sheathed, armoured, aluminium conductor cable 1100 Volt grade 185 Sqmm 3.5 core in trenches/ duct/floor/wall with provision of saddle and lugs, joints etc including connection complete all as specified and directed by the Engr-in-Charge.
Supply and laying XLPE insulated PVC sheathed, armoured, aluminium conductor cable 1100 Volt grade 50 Sqmm 3.5 core in trenches/ duct/floor/wall with provision of saddle and lugs, joints etc including connection complete all as specified and directed by the Engr-in-Charge.
M&L 40mm bore GI tubes light grade for cable protection laid in trenches complete all as specified and directed.
M&L for earthing complete with galvanised steel earth plate electrode 60 cm x 60 cm x 6.00 mm thick burried in ground (earth pit not less than 2.25 m deep below ground level) with top edge of the plate not less than 1.5 m below normal ground level, connected to GI earthing lead wire 4mm dia by means of bolts, nuts, check nuts and washers of GI or steel, GI strip proected by 40 mm bore light grade GI pipe and other end connected to earth test point as directed including funnel with watering pipe 20 mm bore light grade galvanised iron, wire mesh, charcoal or coke common salt laid in alternative layer of 15 cm (complete thickness) all round the earth electrode, concrete earth pit in PCC (1:3:6) type C-1, 50 mm thick pre-cast RCC (1:2:4) type B-1 normal mix cover slab reinforced with 8 mm dia TMT bar 10 cm c/c bothways and single handle of 10 mm dia round bar including necessary excavation, earth work etc. in soft / loose soil and disposal pf soil to a distance n. exc. 50 m and necessary testing on completion all as shown in electrical plate No. 3 MES Schedule Part-I complete all as specified and as directed.
M&L for earthing complete with galvanised steel earth plate electrode 60 cm x 60 cm x 6.00 mm thick burried in ground (earth pit not less than 2.25 m deep below ground level) with top edge of the plate not less than 1.5 m below normal ground level, connected to GI strip 32x6 mm as earthing lead by means of bolts, nuts, check nuts and washers of GI or steel, GI strip proected by 40 mm bore light grade GI pipe and other end connected to earth test point as directed including funnel with watering pipe 20 mm bore light grade galvanised iron, wire mesh, charcoal or coke common salt laid in alternative layer of 15 cm (complete thickness) all round the earth electrode, concrete earth pit in PCC (1:3:6) type C-1, 50 mm thick pre-cast RCC (1:2:4) type B-1 normal mix cover slab reinforced with 8 mm dia TMT bar 10 cm c/c bothways and single handle of 10 mm dia round bar including necessary excavation, earth work etc. in soft / loose soil and disposal pf soil to a distance n. exc. 50 m and necessary testing on completion all as shown in electrical plate No. 3 MES Schedule Part-I complete all as specified and as directed.
S&F, MCCB 4 Pole, 415 V, Adjustable type, 160 Amps with breaking capacity 36 KA including making all fixing arrangement ,cutting welding of existing panel board as per site requirment and painting the disturbed part of panel as per the existing colour of panel and electric connection complete all as specified and directed. Make - L&T Cat no- CM92109OOP1OG or equivalent model from make:- ABB / Legrand.
Supply, installation, testing and commissioning of feeder pillar box CPRI approved of size 1.2m x 0.95m x0.50m, indoor type, totally enclosed, dust and vermin proof, factory made, confirming to IP-54, double door both front and back side, with locking arrangement, prewired, made out of 3mm thick CRCA sheet with 04 Nos legs, MS angle of size 40x40x6mm of size 0.60m long suitably grouted with PCC type C2 ( 1:3:6), using 40mm graded crushed stone aggregates and 15mm thick cement plaster in CM 1:4 over concrete surfaces including two coats of synthetic enamel paint of approved colour over a coat of red oxide primer on still surfaces both internally and externally with aluminium bus bar 600 Amps rated duly colour coated 04 Nos and connection through aluminium busbar of appropriate size to MCCBs ,MCBs , power contactor,timer switch,LED phase indicating lamp and accessories fitted in it for incoming and outgoing cable, including LED multi function meter for measureing voltage ampre , frequency KW/KWHand necessary cable, lugs and glands with following accessories including taking down old unservicaeble feeder pillar box complete all as directed by Engineer-in-Charge. (i) MCCB,200 Amps, 4 pole, 415 volts,25 KA fixed thermal and magnetic setting -01 N0s Make:- L&T /Siemens/ ABB/ Legrand/ Havells ( Incoming). (ii) MCCB,63 Amps, 4 pole, 415 volts,25 KA fixed thermal and magnetic setting -03 N0s Make:- L&T /Siemens/ ABB/ Legrand/ Havells- (outgoing) (iii) MCB,32 Amps, (outgoing)FP ,B curve-02 Nos Make:- L&T /Siemens/ ABB/ Legrand/ Havells- (outgoing) (iv)LED Multifunction meter with CT of required capacity . -01 No. Make:- L&T / Legrand / ABB / Siemens/ Schneider (v) LED Phase indicating lamp RYB- 1 SET of Make:- L&T / Legrand/ Schneider. (vi) Modular Contactor, 40A-4NO, 3 module-01 No. Make:- L&T Cat part No. AUMC2004003 or equivalent model from make:- Schneider / ABB / SIEMENS Note:- Drawing shall be submitted from manufacturer and same shall be got approved by Accepting officer.
M&L Cutting Chases in Brick Walls or any position where directed for Concealed conduit, Pinning in, Making Good to facings where required and Pointing in Cement Mortar 1:3 to making good, cutting not exc. 10 Cm girth, complete all as specified and as directed.
VAGIRATHI ENGINEERING COMPANY
K.P Construction Co
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .